Military Engineer Services Tender
... More
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of etender.up.nic.in - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date26 Feb 2025
Closing Date19 Mar 2025
Tender Amount₹ 35,00,000
Costs
EMD
₹ 70,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_699424_1Tender No
CWE/LKO/EM/T-159 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Dismantling & taking out old/unsv BUS BAR panel and supply and fixing LT bus bar panel OF size – 1 x 0.6 x 0.50 mtr out door type factory made pedastal type, fabricated out of 3.15 mm CRCA sheet and inner sheet of MS black sheet and slopy roof and spray painting two coat insiade and outside with synthetick enamle paint of approved shade over a coat of red oxide primer locking arrangement comprise 50 mm size godredge brass pad lock with duplicate keys two earthly terminal suitable cable gland for all incoming and outgoing cable grouting of feeder piller box 40 cm above ground level by providing 90 cm long angle iron of size 50x50x6 mm welded on all the for corner embeded in PCC 1:2:4 using 20 mm stone agregrate up to 50 cm deep including connection all exisiting cable with with M CCB terminal all as specified and directed by EIC at the site requirment complete including the following component:-
(1) incoming (i) MCCB 4P Thermal magnatic & fixed type 125 Amps , 16 KA -01 No.
(2) Outgiong
(a) Aluminium bus bar rating 200 Amps -04 Nos .
(b) Indicating lamp-01 Set (LED Type)
10
-
-
... More
S&F (in replacement) of automatic street light control panel of 3mm thick MS plate of size 500mm x 500mm x 300mm with fixing on existing pole with sutale size of clamp and nut bolt consisting of time switch digital type with contactor, 63A MCCB, 4 pole, 415 V 25KA with Voltmeter Digital type (0-500V) and Ammeter digital type (0-100A) incl. making electrical connection with sutable size of copper wire etc.
8
-
-
... More
Earthing for LT feeder pillar box complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground earth pit not less than 2.25mtr below normal GL with the top edge of the plate not less than 1.5 mtr below the ground level connected by GI strip of size 32x6 mm thick soldered and revetted to earth plate. GI earth will be protected by using 50mm bore GI pipe (light grade) earth plate to transformer body, LT feeder pillar box and neutral of transformer including flate iron clamp 25x3 mm with nut, bolts and washers complete with watering pipe 20mm bore GI pipe (light grade) and chamber PCC (1:4:8) type D2 using 40mm grade stone aggregate, coping shall be PCC (1:3:6) type C1 using 20mm graded stone aggregate and PCC (1:2:4) type B1 using 20mm graded stone aggregate pit cover 50mm thick re-inforced with 8mm for MS bar at 80mm c/c both way including excavation and earth work and removal of surplus soil complete all as shown in electrical plate No 3 of SSR part and as specified including earth plate packed all sides with charcoal dust, common salt and testing complete including GI sheet funnel, wire mesh etc as directed
23
-
-
... More
Taking down Old UNSV ACSR conductor from LT poles including insulator clamps nut bolts and service connections complete all as specified and directed.
535
-
-
... More
Supplying and laying or fixing in replacement, jointing and testing LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 240 sqmm cross sectional area, 3.5core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items.
220
-
-
... More
- do - but of size 400 Sqmm 3.5 core
315
-
-
... More
S& F Straight through joints (Heat Shrink Kits) for LT underground cable indoor/outdoor type complete for Armoured ,PVC sheathed Aluminium conductor cables Including excavating earth, identifying the fault, making proper joint of cable after rectification & returning soil back to earth, complete all as specified and directed for the following sizes:-
-
-
-
... More
- do - but of size 400 Sqmm 3.5 core
3
-
-
... More
- do - but of size 240 Sqmm 3.5 core
3
-
-
... More
Excavation in trenches in soft/loose soil not exceeding 1.5M wide and not exceeding 1.5 M in depth and getting out, including trimming the sides including forming bottom surface to required levels for laying of cables complete all as specified and directed.
82
-
-
... More
Returning, filling in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick after laying of cable complete all as specified and directed.
44
-
-
... More
Removing surplus excavated material (soil) to a distance not exceeding 50M and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as specified and directed.
38
-
-
... More
M&L for spreading clean dry sand cushioning to under ground cable in layers of 23 cm (8 cm deep before laying of cable and 15cm deep over the cable) after laying the cable in trenches including punning thiockness upto 18 cm complete as directed.
Note :- Only punned thickness will be considered for payment.
40
-
-
... More
Bricks; common burnt clay building bricks, sub-class ‘A’ designation 75 as specified and as directed
3
-
-
... More
M&L for GI tubing (light grade) 100mm bore with all necessary fittings laid in trenches/ under road crossing/ fixed on poles, wall, under floor etc complete all as specified and directed.
5
-
-
... More
All as per item No 17 above but 80 mm bore
5
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%