If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Security and Emergency Services
Eprocure
Opening Date30 May 2023
Closing Date27 Jun 2023
Tender Amount₹ 49,95,000 
Notes
Download

Costs

Summary

8288 Repair / Maintenance Of Chlorine Dosing Pumps, Ci / Gi Pipe Etc And Improvement To Water Supply Installation And Maint Of Security Street Lights Gate Light/ptls, Dg Sets At Rts And Depot Hempur Under Ge (e) Bareilly.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling and taking up or down unserviceable / cracked steel tubing with all fittings including separting the serviceable tubes cleaning the same and Re-laying, jointing old steel tubing and connections in new or old position including new fittings such as bends, elbows, union, tees, reducers etc; as required at site laid in trenches or on floors complete all as specified and as directed of the following sizes :- Note :- Excavation and other earth work will measured and paid separtely for steel tubes / pipes laid in trench

-

-

-

... More
(a) Bore of pipe 100 mm

6

-

-

... More
(b) Bore of pipe 80 mm

6

-

-

... More
(c) Bore of pipe 50 mm

18

-

-

... More
(d) Bore of pipe 40 mm

30

-

-

... More
(e) Bore of pipe 25 mm

36

-

-

... More
(f) Bore of pipe 20 mm

30

-

-

... More
(g) Bore of pipe 15 mm

18

-

-

... More
Supply, Laying, jointing and leakage testing GI Pipe medium grade including all fittings such as bend, tee, elbow, union, reducer etc, laid in trenches and including dismantling and taking down unserviceable / cracked steel tubing with all fittings of the following sizes as complete all as specified and as directed :- Note :- Excavation and other earth work will measured and paid separtely for steel tubes / pipes laid in trench. directed at site of the following sizes :-

-

-

-

... More
(b) Bore of pipe 100 mm

100

-

-

... More
(c) Bore of pipe 80 mm

90

-

-

... More
(d) Bore of pipe 50 mm

400

-

-

... More
(e) Bore of pipe 40 mm

700

-

-

... More
(f) Bore of pipe 25 mm

200

-

-

... More
(g) Bore of pipe 20 mm

300

-

-

... More
(h) Bore of pipe 15 mm

100

-

-

... More
S&F Gun-metal, globe or Gate Valve with iron wheel head, screwed bothe ends for iron pipe, ISI marked including taking down of unserviceabel existing gate valve complete all as specified and directed of the following sizes:-

-

-

-

... More
(a ) 50 mm dia

8

-

-

... More
(b ) 40 mm dia

5

-

-

... More
(c ) 25mm dia

20

-

-

... More
(d ) 20mm dia

20

-

-

... More
(e ) 15mm dia

10

-

-

... More
S&F sluice valve class PN-1.6 heavy duty flanged ends drilled ISI marked confirming to IS: 14846 suitable for folowing bore pipe, wheel operated (Handle) with high tensile stainless steel spindle, including nuts, bolts and jointing with jointing materials etc. including taking out old existing unservicable sluice valve including making arrangement for safe working complete all as specified and directed. Make: BIR, KIRLOSKAR, Kartar

-

-

-

... More
(a) 100 mm bore

5

-

-

... More
(b) 80 mm bore

3

-

-

... More
S&F CI Non Return Sluice Valve flanged ends of class 1.6 PN, size 100mm bore including taking down old existing unserviceable Non Return Valve complete all as specified and directed.

3

-

-

... More
M&L for repairs to leaking joints for cast iron, spigot and socket pipes and fittings, of following sizes of bore in water mains, by burning out old lead joints in position including provision of run lead and including necessary excavation and earht work complete all as specified and directed.

-

-

-

... More
(a) Bore of pipe 150 mm

2

-

-

... More
(b) Bore of pipe 100 mm

10

-

-

... More
(c) Bore of pipe 80 mm

8

-

-

... More
(d ) 50/ 40 mm dia

16

-

-

... More
(e ) 25 mm dia

8

-

-

... More
M&L for tapping from existing 150/100/80mm bore CI water mains by drilling for 15/20mm dia furrel and connection with 40/50mm bore extension line complete all as specified and directed.

6

-

-

... More
Supply and laying in trenches of CI Pipe centrifugally cast spigot & socketed end of size 150mm dia including taking up existing cast iron water mains including all fittings with spigot & socket ends and lead Joints including burning out joints and recovering lead complete all as specified and directed.

-

-

-

... More
All as per Srl Item No.11 here in before but size 100mm dia

60

-

-

... More
All as per Srl Item No.11 here in before but size 80mm dia

80

-

-

... More
S&F for cast iron fittings such as bends, tapers, Tee pieces, Y junction, cross collar, caps and plugs etc of any type as required for bore of pipe up to150 mm dia complete all as specified and directed.

100

-

-

... More
Disconnecting from electric connection carefully the motor from panel board and lifting the submersible pump and motor from bore well including all etc and removing the same to the location (inside / outside building) complete all as directed.

4

-

-

... More
Dismantling the submersible pump assembly capacity 15 HP completely, checking and segregating serviceable / unserviceable parts, cleaning serviceable parts thoroughly by approved method, replacement of wron out parts including necessary lath / machinery work including all new parts as reqd, re-assembling the pump completely lowering the pump alongwith all accessories to the existing location, overhauling, commissioning, testing and connecting up complete including painting all as specified and directed.

4

-

-

... More
Supply and Replacement of following pairs suitable for srl item No 16 for Submersible pump:-

-

-

-

... More
(a) Discharge outlet

4

-

-

... More
(b) Stage casing

4

-

-

... More
(c) Pump shaft

4

-

-

... More
(d) Key for impeller

4

-

-

... More
(e) Key for pump coupling

4

-

-

... More
(f) Bearing sleeve

4

-

-

... More
(g) Stage Bowl bush

4

-

-

... More
(h) DOL Bush

4

-

-

... More
(j) Nut Stud kit

4

-

-

... More
(k) NRV

4

-

-

... More
Dismantling, cutting and removing the burnt windings from the submersible motor of capacity 15 HP, rewinding with suitable size / gauge of super enameled / copper conductor and other approved insulating materials, heating, drying and replacement of existing size of submersible cable including varnishing, overhauling, reassembling the motor, installing, commissioning, testing and connecting up complete all as specified and directed.

4

-

-

... More
Supply only of following parts suitable for ser item No 18 for Submersible motor :-

-

-

-

... More
(a) Oil Seal Set

4

-

-

... More
(b) `O` ring set

4

-

-

... More
(c) Motor bearing Bush set

4

-

-

... More
(d) Complete Pad set (Bearing assembly)

4

-

-

... More
(e) Rotor sleeve set

4

-

-

... More
(f) Thrust plate with ferredo lining

4

-

-

... More
(g) Upper/Lower bearing house

4

-

-

... More
(h) Balancing ring

4

-

-

... More
S & Install in repairs Submersible Pump set 15 HP,100 mtre head, discharge 450 LPM , three phase including taking out the existing pump set complete all as specified & directed . Make:- KSB/Kirloskar

1

-

-

... More
Disconnections of electric connection of centrifugal pump and motor capacity of 25 HP, lifting and removing motor form its existing foundation to the location (in side/outside of building) where directed by the Engr-in-charge. Dismantling the pump and motor of capacity 25 HP, carefully checking, segregating serviceable and unserviceable parts, cleaning the serviceable parts thoroughly by approved method (Pats like stator, rotor, terminal box, bearings shaft, key etc) heating, drying & varnishing including replacement of burnt winding for 25 HP motor with super enameled copper wire of existing gauge and good quality of insulating materials including replacement of unserviceable parts as required including necessary lath / machining work. Reassembling the pump and motor including painting with two coats of synthetic enamel paint after necessary surface preparation, marking of number (SM, MES or srl No) installing to its existing foundation, commissioning, connecting up and testing complete as directed. Note:- Spares shall be measurded and paid separately under respective item of this sch.

4

-

-

... More
Supply only of following parts suitable for ser item No 21 for centrifugal pump and motor.

-

-

-

... More
(a) 25 HP Pump Bearing No 6310 or suitable size

4

-

-

... More
(b) Pump bearing seat suitable for 3 ph 25 HP motor

4

-

-

... More
(c) Motor side cover suitable for 3 ph 25 HP motor

4

-

-

... More
(d) Motor connected plate six hole suitable for 3 ph 25 HP motor

4

-

-

... More
(e) 25 HP Motor Bearing No 6308 or suitable size

4

-

-

... More
(f) 25 HP Motor Bearing No 6309 or suitable size

4

-

-

... More
M&L for Dismantling the Sewage pump set up to 5 HP, carefully checking, segregating serviceable and unserviceable parts, cleaning the serviceable parts thoroughly & including replacement of unserviceable parts as required (Block piston, Nozzle, head block, cupling engine parts & Impaller, gland packing, Pump shaft, pump seal Pump parts) including necessary lath / machining work. Reassembling the pump and engine parts including painting with two coats of synthetic enamel paint after necessary surface preparation, marking of number (SM, MES or srl No) & replacement of unserviceable suction & Delivery PVC pipe, flange, clamps, foot valve etc and testing complete as directed.

2

-

-

... More
Supply and fix Green & Red button operated push type, Star Delta Starter Oil mersed with Single Phase Preventer, Type designation BSA, Operatig current 18Amp, coil voltage 380 _+15% , 3 phase 415V 50 Hz suibtable for 15 HP Submersible Pump and Motor complete with Over load tripping circuit (Max relay (14-20 Amp), Reverse phasing , unbalancing, Low voltage , high voltage upto motor terminal and starting time delay and should be housed in Dust proof, Moisture proof and powder coated sheet metal fabricated box with locking arrengement with extra long life contact with arrengement including taking down of existing starter complete all as specified and directed . Make- Kapil SKN or equivalent

2

-

-

... More
Supply and fix Green & Red button operated push type, Star Delta Starter Oil mersed with Single Phase Preventer, Type designation BSA, Operatig current 28Amp, coil voltage 380 _+15% , 3 phase 415V 50 Hz suibtable for 25 HP Centrifugal Pump and Motor complete with Over load tripping circuit (Max relay (20-40 Amp), Reverse phasing , unbalancing, Low voltage , high voltage upto motor terminal and starting time delay and should be housed in Dust proof, Moisture proof and powder coated sheet metal fabricated box with locking arrengement with extra long life contact with arrengement including taking down of existing starter complete all as specified and directed . Make- Kapil SKN or equivalent

2

-

-

... More
Supply and fix DOL starter three phase 415 volt 50 Hz push button type suitable for 05/7.5 HP centrifugal pump set with arrangement and making the necessary connection in panel and pump set including taking down of existing starter complete all as specified and directed. Make- L&T or equivelent as approved by GE

2

-

-

... More
Disconnections of electric connection of the starter of 15/25/35 HP Pumping set for repairs installed at LT Panel in the pump house, carefully checking the parts throughly & including replacement of unseviceable parts such as electronic Motor Protection relay with inbuilt earth fault protection , Over load protection relay ranging 28-42/30-35 Amp, MNX-32 contractor for starter(Front add on auxilary contact block) and electronic Timers type ST 100, 240/415 Volt, 50 Hz of range 03 - 30 secs complete all as specified & directed. Make- L &T / Havells/Minilec

4

-

-

... More
Material and Labour for cleaning of under ground sump of capacity 10000 Glns at RTS & Depot complete with:- (a) Cleaning of water tanks with high pressure water jet with pressure not exeeding 28Kg/Sqcm and remove all masses algae and dirt. (b) Removal of dirty water alongwith sludge using sludge machines and disposal of the same to a safe distance. (c) Scrubbing of floors using industrial vacuum cleaner. (d) Applying of anti bacterial sterilization to walls floors and roofs of tanks. (e) Removing of all vegitation near by to UG tank and thrown to 50 meters away.

3

-

-

... More
Material and Labour for cleaning of over head Reservoir of capacity 10000 Glns of height up to 21mtr complete with :- (a) Cleaning of water tanks with high pressure water jet with pressure not exeeding 28Kg/Sqcm and remove all masses algae and dirt. (b) Removal of dirty water alongwith sludge using sludge machines and disposal of the same to a safe distance. (c) Scrubbing of floors using industrial vacuum cleaner. (d) Applying of anti bacterial sterilization to walls floors of sump. (e) Removing of all vegitation near by to OH tank and thrown to 50 meters away.

1

-

-

... More
All as per item No 29 here-in-before but over head reservoirs of capacity 25000 Glns at RTS & Depot.

5

-

-

... More
M&L for applying one coat of existing colour paint over a coat of red oxide primer externally on existing MS/GI/CI pipe line for pump & motor and over head tank with arrow mark for up or down of size 100 / 150 mm dia of bore including scraping existing treatment complete all as specifed and as directed.

800

-

-

... More
M & L in repairs single LED Aviation Obstruction light fitting upto 9Watt, Red aluminium body complete all as specified.

3

-

-

... More
Taking down copper/aluminum point wiring complete including fixture and fitting such as switches, ceiling roses, pendants, regulators, sockets, light fittings, holders etc and removing the items from site to store for taking credit (credit for above items should be made as per conditions separately ) and making good disturbed surfaces to match with the existing surfaces of walls, floors etc complete all as specified and directed.

1290

-

-

... More
M & L for point wiring for modular fittings using 1.50 sqmm size, PVC insulated, unsheathed 1100 volts grade single core multi-stranded (FRLS) copper conductor cable in proper colour coding drawn into and in existing non metallic rigid PVC conduit medium grade (not less than 20 mm dia) with metal flush box for mounting of modular fitting and cover plates including one continuous run of PVC insulated (green colour) 1.50 sqmm size stranded FRLS copper conductor cable as in earth wire and connecting all metal parts to common earth dolly incl cutting and chases pinning in for concealed new conduit if required and making good of disturbed surface complete all as specified and directed for One light point / fan point / bell push point controlled by one modular switch 6 Amp. Wire Make- Havells/Polycab/Shalabh

970

-

-

... More
All as per Item No-34 but for One 3 pin 6 amp modular socket out let point controlled by one switch on the same board.

80

-

-

... More
All as per Item No-34 but for One 3 pin 6 amps modular socket out let point on independent board

150

-

-

... More
All as per item no;-34 herein before but 2.5 Sqmm PVC insulated sheathed cable and 2.5 Sqmm cable for earth wire for one 5 pin socket outlet 15 Amps

90

-

-

... More
S&F modular switch, one way 6 Amps, one module of suitable colour complete all as specified and directed. Make-Havells/ Anchor

1200

-

-

... More
S&F modular switch, one way 16 Amps, one module of suitable colour complete all as specified and directed. Make-Havells/ Anchor

90

-

-

... More
S&F modular socket , 6 Amps, 2/3 pin combined, 2 module complete all as specified and directed. Make- Havells/ Anchor

230

-

-

... More
S & F modular socket , 6 Amps/ 16 Amps, 2/3 pin combined, 2 module of suitable colour complete all as specified and directed.Make- Havells/ Anchor

90

-

-

... More
S&F Lamp Holder, PVC/Polycarbonate type with back plate for batten fitting including Lamp LED,aluminium heat sink powder coated white with PC diffuser & B22 base cap 9watt 240 Volt. Make-Havells/ Anchor

280

-

-

... More
S&F ceiling roze, 3 terminals, PVC polycarbonate isolated body.Make- Havells/ Anchor.

690

-

-

... More
S&F modular fan Step regulator 120 watt, 230 Volts, 2 module of suitable colour complete all as specified and directed. Make- Havells/ Anchor

100

-

-

... More
S & F in repairs ceiling fan 1200 mm sweep complete with blades, down rod of suitable size and accessories 230 Volts and marking the serial MES fan nos etc including electric connection with three core flexible PVC insulated copper conductor multistranded cable 1.0 sqmm and taking down old unserviceable ceiling fan deposite in E/M stores for BER etc. Make- Havells/ Crompton/ Bajaj

50

-

-

... More
S & F in repairs Exhaust fan steel body, AC single phase, 230 Volts, 300mm sweep with 04 Nos blades, frame and louvers complete and marking the serial MES fan nos etc including electric connection with three core flexible PVC insulated copper conductor multistranded cable 1.0 sqmm and taking down old unserviceable Exhaust fan deposite in E/M stores for BER etc.Havells/ Crompton/ Bajaj

10

-

-

... More
S & F in repairs LED Tube light fittings 18/20 Watt, 4', T-8 complete with retrofit tube including connecting up with 3 core flexible copper conductor cable of suitable size. Make- Havells/ C &S /Crompton

100

-

-

... More
S&F in repairs LED bulk head luminaire 12 watt with Engineering plastic housing and oval shaped clear prismatic diffuser, heat sink integrated including one no. 12Watt LED lamp .Make- Havells/ C &S /Crompton as directed by Engr-in-Charge.

20

-

-

... More
S & F in repairs LED Ceiling light surface/ Recces mounted, 2'x2' die cast aluminium housing with frosted diffuser including LED lamp 36 Watt.Make- Havells/ C &S /Crompton.

6

-

-

... More
M & L in repairs sub main wiring with 2 run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor in & including PVC Casing & caping all as directed. Wire Make - Shalabh/ Polycab

100

-

-

... More
M & L in repairs sub main wiring with 2 run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn in existing conduit all as directed. Make-RR Kable/ Shalabh/ Polycab

300

-

-

... More
S&F in repairs sheet metal enclousers (DBS) when MCBs to be used 4 way, 415 Volts double door Three Phase & neutral with 200 Amps rated bus bar.Make- Havells/ Indo Asian/HPL

4

-

-

... More
S&F in repairs sheet metal enclousers (DBS) when MCBs to be used 4 way, 240 Volts double door single pole & neutral with 200 Amps rated bus bar complete all as specified and as directed.

32

-

-

... More
S&F in repairs sheet metal enclousers (DBS) when MCBs to be used 8 way, 240 Volt, double door single pole & neutral with 200 Amps rated bus bar complete all as specified and as directed.

20

-

-

... More
S&F Isolator three phase and neutral, four pole 32A-100A, 415Volt complete all as specified and directed.

4

-

-

... More
S&F in repairs MCB single phase and neutral 16A-63A, 230V 10KA. B' curve type complete all as specified and directed.

52

-

-

... More
S&F in repairs MCB SP 6A-32A, 230V. 10KA. B' curve type complete all as specified and directed

205

-

-

... More
Repairs & Maintenance of existing LT Panel board installed at Pump house No-2 ,existing two coat sprey painting over one coat of red oxide primer after proper surface prepration & setting with replacement of panel wiring , setting of existing serviceable items, charging, testing etc after complete with replacement of the following unsv fitments on existing pattern :- (i) MCCB 200 A,415 V, 4 Poles, 36 Ka=1 (ii ) MCCB 100 A,415 V, 4 Poles, 25 ka=3 (iii ) Indicating lamp with Volt & Ameter with CT etc (iv ) Change over 4-poles, 100 Amps=1 (v ) Automatic electronic starter 40 Amp = 2 complete all as specified & directed.

1

-

-

... More
Repairs & Maintenance of existing LT Panel board installed at Pump house No-2 ( Near submersible pump set) ,existing two coat sprey painting over one coat of red oxide primer after proper surface prepration & setting with replacement of panel wiring , setting of existing serviceable items, charging, testing etc after complete with replacement of the following unsv fitments on existing pattern :- (i) MCCB 100 A,415 V, 4 Poles, 25 Ka=2 (iii ) Indicating lamp with Volt & Ameter with CT etc (iv ) Automatic electronic starter 20 Amp = 2 complete all as specified & directed.

1

-

-

... More
Repairs & Maintenance of existing LT Panel board installed at Pump house No-3 ,existing two coat sprey painting over one coat of red oxide primer after proper surface prepration & setting with replacement of panel wiring , setting of existing serviceable items, charging, testing etc after complete with replacement of the following unsv fitments on existing pattern :- (i) MCCB 100 A,415 V, 4 Poles, 25 Ka=2 (iii ) Indicating lamp with Volt & Ameter with CT etc (iv ) Green & Red button operated push type, Star Delta Starter Oil mersed with Single Phase Preventer, Type designation BSA, Operatig current 28Amp, coil voltage 380 _+15% , 3 phase 415V 50 Hz suibtable for 25 HP Centrifugal Pump and Motor complete with Over load tripping circuit (Max relay (20-40 Amp) = 2

1

-

-

... More
M & L for repairs install at Pump house No-3 Automiser (Prop ), phase corrector with over load 415 Volts, type ROP, three phase automatic star delta up to 40 HP and testing complete all as specified & directed of Make-Seco.

1

-

-

... More
Supply and laying in repairs XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked as per IS 7098-I laid in trenches ducts or fixing or passing through GI pipe across the road/path/drains/along wall/floor/pole/equipment etc. cross sectional area including cable lugs of following size including taking down of existing cable complete all as specified and directed.by Engr-in-Charge

-

-

-

... More
(a) LT cable 2 Core 10 Sqmm

1500

-

-

... More
(c) LT cable 4 core 35 Sqmm

400

-

-

... More
(d) LT cable 3.5 core 95Sqmm

200

-

-

... More
Supply and laying dry burnt bricks, sub class ‘B’ old size in cable trenches, as cable protection complete all as specified and directed by Engr-in-Charge.

12750

-

-

... More
Dry sand cushioning to under ground electric cable on layer of 08 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of M.E.S Schedule Part-I complete all as specified and directed.by Engr-in-Charge

128

-

-

... More
Cutting/Boring of road/Hard standing to a size of 30 cm in width and not exceeding 60 cm in depth for laying of protection pipe/water line/Cable including returning filling, Including spreading and providing PCC in 1:2:4 B1 using 20 mm grade stone aggregate for the top 100mm layer, complete all as specified and directed.by Engr-in-Charge

48

-

-

... More
Supply and laying galvanised iron pipe 80mm bore light grade fixed to poles with steel clamps laid under road crossing, fixed to wall etc complete all as specified and directed by Engr-in-charge. Make : Jindal/TATA/Prakash

30

-

-

... More
Supply and laying galvanised iron pipe 25mm bore light grade fixed to poles with steel clamps laid under road crossing, fixed to wall etc complete all as specified and directed by Engr-in-charge. Make : Jindal/TATA/Prakash

60

-

-

... More
M & L for Collection of water sample from each Bore Well for testing of Physical, Bacteriological and Chemical analysis( Quarterly report) of portability for drinking purpose from Govt/Authorised lab complete all as specified and as directed.

20

-

-

... More
M & L for cleaning away all Grass, vegetation, saplings, shurbs, brushedwood, undergrowth, un-wanted plants, roots and removing the rubbish up to distance of 50 Mtrs outside the periphery of the area under clearance all as specified and as directed by Engineer -in-Charge.

20000

-

-

... More
Supply only ALTOCH (Calcium based granular disinfectant) Make : Declibac.

600

-

-

... More
Supply only Chlorine tablets contained in plastic cylindrical sealed disposable sanitizer refill for disinfection of drinking water with arrangement for controlled release of disinfectant in water.

5

-

-

... More
Supply only flat type 6 Sqmm three core, PVC sheathed copper conductor cable suitable for submersible pump and motor.

300

-

-

... More
Supply only Nut bolts with washers complete off sizes.

120

-

-

... More
Supply only water chlorine test Kit complete.

4

-

-

... More
Supply only testing regent Tolbine of 100 ml bottle for water chlorine test complete.

4

-

-

... More
S & F PVC LT over hèad electric supply line separator/ spacer for two wires complete as specified & directed.

100

-

-

... More
S & F PVC LT over hèad electric supply line separator/ spacer for three wires complete as specified & directed.

300

-

-

... More
S & F PVC LT over hèad electric supply line separator/ spacer for four wires complete as specified & directed.

100

-

-

... More
S&F in repairs LED Bldg security light 25Watt, IP-65 complete and including suitable electric connection with flexible 1.0 sqmm PVC insulated copper conductor cable 1100 V grade & GI pipe bracket with clamps, nut bolts etc including taking down the old unsv fittings. Make-Havells/ C &S /Crompton

70

-

-

... More
Supply and fixing in repairs LED 45 watt, decorative indirect post top, for garden landscape lighting with IP65 protection, resistant to impact and corrosion anti glare and uniform distribution and necessary modification of existing GI pole including taking down existing old unsv fittings complete all as specified and as directed .Make- Crompton/Bajaj/C&S

4

-

-

... More
Supply and fixing in repairs LED street light 45 Watt, 220V 50Hz made up pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP65 protection and provision of bracket for fixing of street light fittings bend to shape, made out of bracket suitable size GI pipe light grade upto 1.50m long fixed including MS clamps of size 40 x 4 mm, bolt, nuts & washer to fix with LT pole/Wall with two coats of aluminium paint over a coat of red oxide primer including taking down existing old unsv fittings complete all as specified and as directed by Engr-in-Charge Make: - Bajaj/Philips/wipro/ Crompton

239

-

-

... More
Supply and fixing in repairs LED street light 60 Watt, 220V 50Hz made up pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP65 protection and provision of bracket for fixing of street light fittings bend to shape, made out of bracket suitable size GI pipe light grade upto 1.50m long fixed including MS clamps of size 40 x 4 mm, bolt, nuts & washer to fix with LT pole/Wall with two coats of aluminium paint over a coat of red oxide primer including taking down existing old unsv fittings complete all as specified and as directed by Engr-in-Charge Make: - Bajaj/Philips/wipro/ Crompton

50

-

-

... More
Supply and fixing in repairs LED Floodlight 60 Watt, 220V 50Hz made up pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection along with mounting bracket fixing for LT pole all as specified and directed. Make:- Wipro / Philips/Bajaj/ Crompton

130

-

-

... More
Supply and fixing in repairs LED Floodlight 120 Watt, 220V 50Hz made up pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection along with mounting bracket fixing for LT pole including necessary arrangment of cable from floodlight to pole including taking down existing old unsv fittingsand all as specified and directed. Make: - Wipro / Philips/Bajaj/ Crompton

4

-

-

... More
Supply and fixing in repairs LED Floodlight 250 Watt, 220V 50Hz made up pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection along with mounting bracket fixing for LT pole including necessary arrangment of cable from floodlight to pole including taking down existing old unsv fittingsand all as specified and directed. Make: - Wipro / Philips/Bajaj/ Crompton

2

-

-

... More
Repairs/replacement of solar street light by dismantling panel, battery, PVC battery box, PVC wire LED light etc complete all as specified and directed.

3

-

-

... More
Supply only for PVC Battery box complete all as specified and directed-

3

-

-

... More
Supply only for solar LED light 12 Watt complete all as specified and directed

3

-

-

... More
Supply only for solar panel 50 watt complete all as specified and directed.

3

-

-

... More
Supply only for solar charger controller panel complete all as specified and directed.

3

-

-

... More
Supply only for battery 12 volt 40 AH fully complete all as specified and directed.

3

-

-

... More
Supply and fixing in repairs LED out door divices for street light 45/60/72 Watt, 220V 50Hz , complete all as specified and directed.

50

-

-

... More
S & Install Automatic Out door single phase Street light Timer Switch 230 Volts with batery back up fixing on LT over head line Electric Pole complete making functional all as specified & directed. Make- L &T/ Siemens/RMG

6

-

-

... More
M & L for Junction boxes with PVC water tight encloser, ready made type, aluminium bus bar 25x3 mm, 200mm long fixed on post insulators, nut & bolts, MS Camps including 2.5 sqmm cable for street light connection& controlling with one number single pole MCB 6A, 230 Volts complete.

50

-

-

... More
S & F MCCB four Pole, 415V of capacity 63Amps, 36KA with suitable box/ Sheet enclouser water tight with IP-66 protecion complete fixed on LT pole by means of proper, clamps, nuts &bolts etc for controlling street lights etc.

10

-

-

... More
M&L for carrying out general servicing and repairs to Engine of DG set of the following capacity installed at varouse pump house at RTC & Depot Hempur including servicing of water pump, replacement of unserviceable spares, carrying out 'B' Check as per manufacturer's recommendations including replacement of oil filters, fuel/diesel filters with 'O' rings, Turbo fileter, super bypass filter and Engine Oil and toping up of coolant up to required level complete all as specified and as directted by Engr-in-Charge. Notes : (i) Supply only Engine Oil and coolant shall be measured and paid separetely. (ii) Rate quoted is inclusive of Oil filters, diesel filters with O rings, hose pipe and diesel pipe with clamps and turbo filter.. (iii) All the spares require replacement during servicing shall be measured and paid separately as 'Supply only' (iv) Servicing of Radiator & self starter shall be measured and paid separately

-

-

-

... More
(a) 125 KVA DG set

1

-

-

... More
(b) 63 KVA DG set

1

-

-

... More
(c ) 40 KVA DG Set

1

-

-

... More
(d) 30 KVA DG Set

1

-

-

... More
(e) 25 KVA DG Set

1

-

-

... More
Supply only Air cleaner/filter of existing size suitable up to125 KVA DG Set .

5

-

-

... More
Supply only Engine oil 15W-40W or as per manufacturer's recommendation.

110

-

-

... More
Supply only Radiator Coolant

50

-

-

... More
M&L for Cleaning and servicing of radiator assembly including cooler of the capacity DG Set upto 125 KVA by circulating de-scaling solution including repairs and replacement of worn out rubber hoses with clamps, mounting boots and bolts, recrification of leakages by welding/ brazing etc. complete all as directed.

5

-

-

... More
M & L for supply and fixing against repairs Automatic Voltage Regulator (AVR) suitable for uptp 63 KVA, connecting with panel circuit, starting and testing on load all as specified and directed by Engineer-in-charge

3

-

-

... More
Supply and replacement lead acid battery 12 V 150Ah complete (Initially charged) and connected to DG sets complete all as directed [Make: Exide/ SF/ Amaron]

4

-

-

... More
M & L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.3 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metres below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts,check nuts, nuts and washers of GI or steel all as shown in electrical plate No 3 of SSR-I 2009. GI wire protected by GI pipe light grade 15mm dia connected to earth test point including excavation in any type of soil, returning filling, disposal of soil, earthing pit in PCC (1:3:6) type C1,RCC (1:2:4) type B1 precast cover slab with one handle made out of 8 mm dia round bar,20 mm dia (medium grade) watering pipe and providing layer of charcoal or coke and salt in alternative layers complete as specified or directed & including testng on completion NOTE:- Tenderers may note that amount of credit will be deducted from the total amount arrived at the time of Acceptance of contract.)

10

-

-

... More
All as per Srl item No. 103 here in before but Using GI strip 32x5 mm as earthing lead.

20

-

-

... More
Dismantling the exisiting damaged valve pit and construction of Valve pit of size 110cm x110cm x 90cm (internal dimensions), brick construction, including all necessary excavation and earth work in hard/loose soil, returning , filling in disposal of surplus spoil to distance not exceeding 50m and depositing where directed, PCC in foundation of the mix 1:4:8, type D-2, (Using 40mm graded crushed aggregate) brick masonry in cement mortar 1:4, rendering 12mm thick in cement mortar 1:4, internally, finished even and fair and pointing flush externally as the work proceeds in the same mortar mild steel frame, MS sheet cover 3.15 mm thick with handle and locking arrangement, painting all the exposed M.S work with two coats of synthetic enamel paint of the tint over a coat of red oxide primer and painting all the M.S embedded in PCC with two coats of black bituminous paint complete all as specified and directed.

10

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.