Military Engineer Services Tender

If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date24 Jul 2024
Closing Date6 Sep 2024
Tender Amount₹ 3,63,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Taking down old damage ACSR conductor of any size and type complete all as specified and directed.

54.9

-

-

... More
Dismantling/Taking down Old service cable/LT UG cable from ground/Poles/walls of any size/type from bldgs all as specified and directed by the Engineer-in-Charge. Note for Sr No 2 to 5:- A BOO will be conveyed by CWE for identification of E/M material to be dismantaled prior to commencement of work. Item wise qtys shall be identified by BOO after physical check at site and BPs shall be approved from CWE prior to dismantaling of materials.

2730

-

-

... More
Re-laying of LT UG cable in trenches of any size/type complete all as specified and directed by Engineer-in-Charge. Note: Payment for excavation in trenches, brick, river sand for cable cushioinng will be measured under relevant items complete all as specified and directed.

820

-

-

... More
M&L for scraping the existing old surface of HT/ LT poles and painting with one coat of primer and two coats of silver paint and marking of poles with 30 cms black and 30 cms white band upto 1 meter height of pole LT and marking of HT poles with Red and white paint and marking of poles numbers with standard size ( 15 cms x 7.5 cms ) of letters complete all as specified and directed.

129

-

-

... More
M&L for scraping the existing old surface of two pole Structure and painting with one coat of primer and two coats of silver paint and marking of poles with 30 cms Red and 30 cms white band upto 1 meter height of HT poles with Red and white paint and marking of poles numbers with standard size ( 15 cms x7.5 cms ) of letters complete all as specified and directed.

10

-

-

... More
M&L for scraping the existing old surface of four pole Structure and painting with one coat of primer and two coats of silver paint and marking of poles with 30 cms Red and 30 cms white band upto 1 meter height of HT poles with Red and white paint and marking of poles numbers with standard size ( 15 cms x7.5 cms ) of letters complete all as specified and directed.

12

-

-

... More
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade (earthed) cable of size 3 core 95 sqmm complete all as specified and directed. Note: Excavation, brick work and sand for cable cushion shall be measured and paid separately under relevant items.

5562

-

-

... More
M&L in replacement of cable XLPE insulated heavy duty electric cable with Stranded aluminium conductor, 1100 volts grade, passing through trenches/ducts/pipes and climbing on poles/walls including fixing with proper size of aluminium lugs. For the following sizes complete all as specified and directed:- Note: Excavation, brick work and sand for cable cushion shall be measured and paid separately under relevant items.

-

-

-

... More
16 Sq mm 2 Core

1195

-

-

... More
10 Sq mm 4 Core

5300

-

-

... More
16 Sq mm 4 Core

1870

-

-

... More
25 Sq mm 4 Core

4770

-

-

... More
35 Sq mm 3.5 Core

445

-

-

... More
50 Sq mm 3.5 Core

275

-

-

... More
70 Sq mm 3.5 Core

65

-

-

... More
95 Sq mm 3.5 Core

120

-

-

... More
120 Sq mm 3.5 Core

485

-

-

... More
150 Sq mm 3.5 Core

795

-

-

... More
185 Sq mm 3.5 Core

310

-

-

... More
240 Sq mm 3.5 Core

455

-

-

... More
300 Sq mm 3.5 Core

640

-

-

... More
400 Sq mm 3.5 Core

530

-

-

... More
M&L for earthing complete with galvanized steel earth plate electrode size 600 x 600 x 6 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized iron strip 32X6 mm earth lead by means of bolts, nuts, check nuts and washers of galvanized steel and GI pipe medium grade 20 mm dia bore for watering funnel with wire mesh. CI cover with frame, 40 mm dia GI pipe light grade for earthing electrode protection, PCC chamber pit with PCC (1:3:6 ) type C- 1, 40 mm thick precast RCC M-25 (Design Mix) cover reinforce with 8 mm dia TMT bars @ 10 cm c/c both ways and lifting handle, excavation and earth work all as shown in electrical plate No 3 of SSR Part-I (2009) connected to earthing test point all as specified or indicated including testing on completion. Note:- (i). Excavation, returning filling and removing of surplus soil is deemed to be included in the unit rate. (Description continue from last item) (ii) Cost of PCC pit, RCC Pit cover with funnel & wire mesh, water pipe, test point is demmed to be included in the unit rate in addition to Item No.1(a) to 1(e) of premeable (Notes) under sub-heading earthing, specified in SSR Part-II. No.1(a) to 1(e) of premeable (Notes) under sub-heading earthing, specified in SSR Part-II. (iii) The unit rate also includes the cost of GI earth lead and GI pipe for protection of earth strip up to 7.5 metre (any variation in length shall be adjusted through deviation order). iv) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.

116

-

-

... More
Supply , installation, commissioning and testing of main LT panel ( Main LT Panel No-04 Zone-11) Made out of CRCA sheet 3.15 mm thick sheet steel Outdoor type, factory made by CPRI approved manufacturer, totally enclosed, dust and vermin proof (protection class IP 54), (front & back opening) with locking arrangement, double door duly compartmentalized with extended canopy at the top, the panel shall be duly powder coated with colour shade RAL 7035 siemens gray pure polyester or as directed by AGE (I), adopting 8 tank pretreatment of fabricated job before powder coated & including One danger notice plate 1.6 mm thick. All inner connections to outgoing feeders shall be made with TPN aluminum bus bar of rating not less than the current carrying capacity of resperctive feeder, all busbar shall be covered with colour coded heat shirinkable sleeve, the complete panel shall be mounted on ISMC of 75x40 mm length of leg not less than 90cm including 30 cm grouting duly painted with black enamel paint, Digital ammeter (0-400) with ASS-01 No, current transformer of rating 400/5A-03 Nos, Digital Voltmeter with VSS (0-500V)-01 No, including suitable size cable lugs and PCC (1:2:4) type B1 foundation complete all as specified and directed by Engineer-in-Charge. The panel consist of the following switchgears :- (a) Aluminium bus bar of capacity 800 Amp . (b) Incoming MCCB 4 pole 500 Amp 36 KA breaking capacity along-with spreader terminals with adjustable thermal & fixed magnetic release type, Ics=100 % Icu – 01 Nos. (c) Outgoing MCCB 4 pole 250 Amp 25 KA breaking capacity along-with spreader terminals with adjustable thermal & fixed magnetic release type, Ics=100 % Icu – 03 Nos. (d) Digital volt meter 0 to 500 volt with selector switch – 01 No. (e) Digital Amp meter 0 to 500 Amp with CT of suitable ratio and selector switch – 01 No. (f) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
Supply , installation, commissioning and testing of main LT panel ( Main LT Panel No-05 Zone-11) Made out of CRCA sheet 3.15 mm thick sheet steel Outdoor type, factory made by CPRI approved manufacturer, totally enclosed, dust and vermin proof (protection class IP 54), (front & back opening) with locking arrangement, double door duly compartmentalized with extended canopy at the top, the panel shall be duly powder coated with colour shade RAL 7035 siemens gray pure polyester or as directed by AGE (I), adopting 8 tank pretreatment of fabricated job before powder coated & including one danger notice plate 1.6 mm thick. All inner connections to outgoing feeders shall be made with TPN aluminum bus bar of rating not less than the current carrying capacity of resperctive feeder, all busbar shall be covered with colour coded heat shirinkable sleeve, the complete panel shall be mounted on ISMC of 75 x 40 mm length of leg not less than 90cm including 30 cm grouting duly painted with black enamel paint, Digital ammeter (0-400) with ASS-01 No, current transformer of rating 400/5A-03 Nos, Digital Voltmeter with VSS (0-500V)-01 No, including suitable size cable lugs and PCC (1:2:4) type B1 foundation complete all as specified and directed by Engineer-in-Charge. The panel consist of the following switchgears :- (a) Aluminium bus bar of capacity 800 Amp (b) Incoming MCCB 4 pole 500 Amp 36 KA breaking capacity along-with spreader terminals with adjustable thermal & fixed magnetic release type, Ics=100 % Icu – 01 Nos. (c) Outgoing MCCB 4 pole 350 Amp 25 KA breaking capacity along-with spreader terminals with adjustable thermal & fixed magnetic release type, Ics=100 % Icu – 02 Nos. (d) MCCB 4 pole 160 Amp 25 KA breaking capacity along-with spreader terminals with adjustable thermal & fixed magnetic release type, Ics=100 % Icu – 01 Nos. (e) Digital volt meter 0 to 500 volt with selector switch – 01 No. (f) Digital Amp meter 0 to 500 Amp with CT of suitable ratio and selector switch – 01 No. (g) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three.. Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
Supply , installation, commissioning and testing of main LT panel ( Main LT Panel No-03 Zone-14) Made out of CRCA sheet 3.15 mm thick sheet steel Outdoor type, factory made by CPRI approved manufacturer, totally enclosed, dust and vermin proof (protection class IP 54), (front & back opening) with locking arrangement, double door duly ccompartmentalized with extended canopy at the top, the panel shall be duly powder coated with colour shade RAL 7035 siemens gray pure polyester or as directed by AGE (I), adopting 8 tank pretreatment of fabricated job before powder coated & including One danger notice plate 1.6 mm thick. All inner connections to outgoing feeders shall be made with TPN aluminum bus bar of rating not less than the current carrying capacity of resperctive feeder, all busbar shall be covered with colour coded heat shirinkable sleeve, the complete panel shall be mounted on ISMC of 75 x 40 mm length of leg not less than 90cm including 30 cm grouting duly painted with black enamel paint, Digital ammeter (0-400) with ASS-01 No, current transformer of rating 400/5A-03 Nos, Digital Voltmeter with VSS (0-500V)-01 No, including suitable size cable lugs and PCC (1:2:4) type B1 foundation complete all as specified and directed by Engineer-in-Charge. The panel consist of the following switchgears :- (a) Aluminium bus bar of capacity 600 Amp . (b) Incoming MCCB 4 pole 350 Amp 36 KA breaking capacity along-with spreader terminals with adjustable thermal & fixed magnetic release type, Ics=100 % Icu – 01 Nos. (c) Outgoing MCCB 4 pole 250 Amp 25 KA breaking capacity along-with spreader terminals with adjustable thermal & fixed magnetic release type, Ics=100 % Icu – 02 Nos. (d) MCCB 4 pole 32 Amp 16 KA breaking capacity along-with spreader terminals with adjustable thermal & fixed magnetic release type, Ics=100 % Icu – 01 Nos. (e) Digital volt meter 0 to 500 volt with selector switch – 01 No. (f) Digital Amp meter 0 to 500 Amp with CT of suitable ratio and selector switch – 01 No. (g) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three. Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu.

1

-

-

... More
Supply and install, testing and commissioning of Distribution transformer mounted on masonry platform step down 11KV/0.433KV three phase complying with IS: 1180 (part-1) 1977 with latest amendment, outdoor type double copper wound suitable for 50 Hz system of capacity 250 KVA, Oil immersed naturally cooled delta connected on HT side and star connected on LT side, vector group DYN-11 provided with OFF load tap changer to vary secondary voltage from -7.5% to +7.5% in step of 2.5%. Losses should be confined to the limits specified as follows: maximum allowable losses at full load (100%) & half load (50%) shall not be exceeded 1.35% & 0.93% respectivly as per GIRHA RATING percentage Impedance: 5 % Losses and impedance are subjected to tollerance as specified in IS 1180:2014. The Transformers should be supplied with first filling of Oil confirming to IS 335. The transformer should have both side cable end box with netural brought out complete all as directed by Enginer-in-Charge and installation of transformer shall be carried out as per IS 10028 and comprising with the following standard fittings and technical compliances:- (a). Lifting lug for transformer and tank. (b). Earthing terminal rating and diagram plate. (c) Air release device. (d). Oil filling inlet pipe with plug. (e ). Drain outlet pipe with brass gate valve. (f). Conservator tank with Oil level indicator. (g). Silica jel breather. (h) First fill of Oil upto level including conservator tank with fresh new Oil confirming to IS335. (j). Type of cooling: Oil and Natural Air. (k). Type connection: Delta/star (l). Vector group : DYN 11. (m). Temperature rise over an ambient of 50*C maximum. (n) Cable end box on both side for HT/LT cables of suitable size. (o). Provision of thermometer with pocket. (p). Provision of Oil and winding temperature gauge. Note :- Nessessary plateform for transforemer as per recommended by OEM, fencing cage and gate alongwith danger notice board as per codal provision shall be provided by the contractor in the above quoted rate.

3

-

-

... More
Supply, installation, testing and commissioning of outdoor type 126 KVAR rated Automatic power factor correction (APFC) capacitor bank suitable for 415V, 3 phase 50Hz with 10 steps of 12 stage APFC relay for MPP-H capacitors of (1x1,2x1,3x1,5x1,10x1,15x1,20x2,25x2) KVAR and housed in highly functional enclosure of size not less than 1100x1000x300mm made from 3.15mm thick CRCA sheet dust & vermin proof of IP-64 protection, with anticorrosive coating and finally powder coated Panel with front opening shutters with suitable angle iron stand complete copper busbar of capacity 160 Amps and panel wiring with FRLS cable and PCC (1:2:4) type B-1 in foundation including earth work complete comprising of the following. (a) 12 stage APFC relay 3-CT NAAC 3P-12, - 01 No (b) CT-200/5 - 01 No (c) MCCB TP DN2 160Amps. DN2 160M - 01 No (d) Spreader link set 160Amps - 01 No (e) MCB TP 63 Amps - 04 Nos (f) MCB TP 32 Amps - 06 Nos (g) MCB SP 6 Amps - 04 Nos (h) MCB SP 2 Amps - 10 Nos (j) Contactor MNX25 - 04 Nos (k) Contactor MOC 10KVAR - 01 No, 15KVAR - 01 No, 20 KVAR - 02 No and 25KVAR - 02 Nos (l) Capacitor Heavy duty 25 KVAR - 02 No, 20 KVAR - 02 Nos, 15 KVAR - 01 No, 10 KVAR - 01 No, 5 KVAR - 01 No, 3 KVAR - 01 No, 2 KVAR - 01 No and 1 KVAR - 01 No (m) Schezler switch - 08 Nos (n) LED Indicator lamp - 08 Nos (o) Panel cooling fan 8.5 inch - 01 No

3

-

-

... More
Supply , installation, commissioning and testing of (main LT panel Zone 17 (FP-01 - Officers MD Accn)) Made out of CRCA sheet 3.15 mm thick sheet steel outdoor type, factory made by CPRI approved manufacturer, totally enclosed, dust and vermin proof (protection class IP 54), (front&back opening) with locking arrangement, double door duly compartmentalized with extended canopy at the top, the panel shall be duly powder coated with colour shade RAL 7035 siemens gray pure polyester or as directed by Engr-in-Charge, adopting 8 tank pretreatment of fabricated job before powder coated & including one danger notice plate 1.6 mm thick Main aluminum bus bar with capacity of 160 A TPN all inner connections to outgoing feeders shall be made with TPN aluminum bus bar of rating not less than the current carrying capacity of resperctive feeder, all busbar shall be covered with colour coded heat shirinkable sleeve, the complete panel swhall be mounted on ISMC of 75x40 mm length of leg not less than 90cm including 30 cm grouting duly painted with black enamel paint, Digital ammeter (0-400) with ASS-01 No, current transformer of rating 400/5A-03 Nos, Digital Voltmeter with VSS (0-500V)-01 No, including suitable size cable lugs and PCC (1:2:4) type B1 in foundation including earth work complete all as specified and directed by Engineer-in-Charge. The panel consist of the following switchgears :- INCOMING MCCB 4 pole 100A 25 KA breaking capacity- 01 No OUT GOING MCCB 4 pole 63 A 16 KA breaking capacity- 03 Nos LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 800 Amps rated bus bar & comprising the following switch gear ( Zone 17 (FP-02 - Officers MD Accn)) INCOMING MCCB 4 pole 500 A 36 KA breaking capacity- 01No OUT GOING MCCB 4 pole 400 A 36 KA breaking capacity- 02 No MCCB 4 pole 250 A 25 KA breaking capacity- 01 No MCCB 4 pole 63 A 16 KA breaking capacity- 01 No MCCB TPN- 32 A breaking capacity 16 KA- 04 No LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu.

1

-

-

... More
All as per item Ser.No. 18.00 above but 600 Amps rated bus bar & comprising the following switch gear ( Zone 17 (FP-03 - Officers MD Accn)). INCOMING MCCB 4 pole 350A 36 KA breaking capacity- 01 No OUT GOING MCCB 4 pole 250 A 25 KA breaking capacity- 02 Nos MCCB 4 pole 63 A 16 KA breaking capacity- 01 Nos MCCB TPN- 32 A - breaking capacity 16 KA- 03 Nos LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 400 Amps rated bus bar & comprising the following switch gear (Zone 17 (FP-04 - Officers MD Accn)) INCOMING MCCB 4 pole 250 A 36 KA breaking capacity- 01 Nos OUT GOING MCCB TPN- 32 A breaking capacity 16 KA- 06 Nos LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 320 Amps rated bus bar & comprising the following switch gear ( Zone 17 (FP-05 - Officers MD Accn)) INCOMING MCCB 4 pole 200 A 25 KA breaking capacity- 01 No OUT GOING MCCB 4 pole 160 A 25 KA breaking capacity- 02 Nos MCCB TPN- 32 A breaking capacity 16 KA- 02 No LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 250 Amps rated bus bar & comprising the following switch gear ( Zone 17 (FP-06 - Officers MD Accn)) INCOMING MCCB 4 pole 160 A 25 KA breaking capacity- 01 No OUT GOING MCCB TPN- 32 A breaking capacity 16 KA - 04 Nos LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 160 Amps rated bus bar & comprising the following switch gear ( Zone 17 (FP-07 - Officers MD Accn)) INCOMING MCCB 4 pole 100 A 25 KA breaking capacity- 01 No OUT GOING MCCB 4 pole 160 A 25 KA breaking capacity- 02 Nos MCCB TPN- 32 A breaking capacity 16 KA- 02 Nos LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 400 Amps rated bus bar & comprising the following switch gear ( Zone 17 (FP-08- Officers MD Accn)) INCOMING MCCB 4 pole 250 A 36 KA breaking capacity- 01 No OUT GOING MCCB 4 pole 160 A 25 KA breaking capacity- 02 Nos MCCB 4 pole 63 A 16 KA breaking capacity- 03 Nos LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 250 Amps rated bus bar & comprising the following switch gear (Zone 17 (FP-09- Officers MD Accn)) INCOMING MCCB 4 pole 160 A 25 KA breaking capacity- 01 No OUT GOING MCCB TPN- 32 A -breaking capacity 16 KA - 03 Nos LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 600 Amps rated bus bar & comprising the following switch gear ( Zone 11 (FP-01- JCOs/OR Md Accn)) INCOMING MCCB 4 pole 350A 36 KA breaking capacity- 01No OUT GOING MCCB 4 pole 160A 25 KA breaking capacity- 02Nos MCCB TPN- 32 A -breaking capacity 16 KA - 05 Nos LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 320 Amps rated bus bar & comprising the following switch gear ( Zone 11 (FP-02- JCOs/OR Md Accn)) INCOMING MCCB 4 pole 200 A 25 KA breaking capacity- 01 No OUT GOING MCCB TPN- 32 A -breaking capacity 16 KA- 08 LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 320 Amps rated bus bar & comprising the following switch gear ( Zone 11 (FP-03- JCOs/OR Md Accn)) INCOMING MCCB 4 pole 200 A 25 KA breaking capacity- 01 No OUT GOING MCCB 4 pole 160 A -breaking capacity 16 KA- 02 MCCB 4 pole 100 A 16 KA breaking capacity- 01 No LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 160 Amps rated bus bar & comprising the following switch gear ( Zone 11 (FP-04 JCOs/OR Md Accn)) INCOMING MCCB 4 pole 100 A 25 KA breaking capacity- 01 No OUT GOING MCCB TPN- 32 A -breaking capacity 16 KA - 03 No LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 250 Amps rated bus bar & comprising the following switch gear ( Zone 11 (FP-05- JCOs/OR Md Accn)) INCOMING MCCB 4 pole 160 A 25 KA breaking capacity- 01 No OUT GOING MCCB TPN- 32 A -breaking capacity 16 KA - 05 Nos LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 600 Amps rated bus bar & comprising the following switch gear ( Zone 11 (FP-06- JCOs/OR Md Accn)) INCOMING MCCB 4 pole 400 A 36 KA breaking capacity- 01 No OUT GOING MCCB 4 pole 350A 36 KA breaking capacity- 02 Nos LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 600 Amps rated bus bar & comprising the following switch gear ( Zone 11 (FP-07- JCOs/OR Md Accn)) INCOMING MCCB 4 pole 350A 36 KA breaking capacity- 01 No OUT GOING MCCB 4 pole 200A 25 KA breaking capacity- 02 Nos MCCB TPN- 32 A - breaking capacity 16 KA-04 No LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 320 Amps rated bus bar & comprising the following switch gear ( Zone 11 (FP-08- JCOs/OR Md Accn) INCOMING MCCB 4 pole 200 A 25 KA breaking capacity- 01 No OUT GOING MCCB 4 pole 63 A 16 KA breaking capacity- 04 Nos LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 250 Amps rated bus bar & comprising the following switch gear ( Zone 11 (FP-09- JCOs/OR Md Accn) INCOMING MCCB 4 pole 160 A 25 KA breaking capacity- 01 No OUT GOING MCCB 4 pole 63 A 16 KA breaking capacity- 04 Nos LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 600 Amps rated bus bar & comprising the following switch gear ( Zone 11 (FP-10- JCOs/OR Md Accn)) INCOMING MCCB 4 pole 350A 36 KA breaking capacity- 01No OUT GOING MCCB 4 pole 250A 36 KA breaking capacity- 02No MCCB 4 pole 100 A 16 KA breaking capacity- 01No LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 160 Amps rated bus bar & comprising the following switch gear ( Zone 11 (FP-11- JCOs/OR Md Accn)) INCOMING MCCB 4 pole 100 A 25 KA breaking capacity- 01No OUT GOING MCCB TPN- 32 A breaking capacity 16 KA - 05 Nos LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 400 Amps rated bus bar & comprising the following switch gear ( Zone 11 (FP-12- JCOs/OR Md Accn)) INCOMING MCCB 4 pole 250A 36 KA breaking capacity- 01 No OUT GOING MCCB 4 pole 200A 25 KA breaking capacity- 02 Nos MCCB TPN- 32 A breaking capacity 16 KA - 02 No LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 320 Amps rated bus bar & comprising the following switch gear ( Zone 11 (FP-12- JCOs/OR Md Accn)) INCOMING MCCB 4 pole 200 A 25 KA breaking capacity- 01 Nos OUT GOING MCCB 4 pole 63 A 16 KA breaking capacity- 04 Nos MCCB TPN- 32 A breaking capacity 16 KA - 01 No LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 600 Amps rated bus bar & comprising the following switch gear ( Zone 11 (FP-14- JCOs/OR Md Accn)) INCOMING MCCB 4 pole 400A 36 KA breaking capacity- 01 No OUT GOING MCCB 4 pole 350A 36 KA breaking capacity- 02 Nos MCCB 4 pole 63 A , 16KA breaking capacity- 02 Nos LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 600 Amps rated bus bar & comprising the following switch gear ( Zone 11 (FP-15- JCOs/OR Md Accn)) INCOMING MCCB 4 pole 350A 36 KA breaking capacity- 01No OUT GOING MCCB 4 pole 200A 25 KA breaking capacity- 02 Nos MCCB TPN- 32 A breaking capacity 16 KA - 04 Nos LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 320 Amps rated bus bar & comprising the following switch gear ( Zone 11 (FP-16- JCOs/OR Md Accn)) INCOMING MCCB 4 pole 200 A 25 KA breaking capacity- 01 No OUT GOING MCCB 4 pole 63 A, 16 KA breaking capacity- 04 Nos MCCB TPN- 32 A breaking capacity 16 KA - 02 No LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 600 Amps rated bus bar & comprising the following switch gear ( Zone 11 (FP-17- JCOs/OR Md Accn)) INCOMING MCCB 4 pole 350A 36 KA breaking capacity- 01 No OUT GOING MCCB 4 pole 200A 25 KA breaking capacity- 02 Nos MCCB 4 pole 63 A, 16 KA breaking capacity- 02 Nos LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 320 Amps rated bus bar & comprising the following switch gear ( Zone 11 (FP-18- JCOs/OR Md Accn)) INCOMING MCCB 4 pole 200A 25 KA breaking capacity- 01 No OUT GOING MCCB 4 pole 100A 16 KA breaking capacity- 02 Nos MCCB TPN- 32 A breaking capacity 16 KA - 04 Nos LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 160 Amps rated bus bar & comprising the following switch gear ( Zone 11 (FP-19- JCOs/OR Md Accn)) INCOMING MCCB TPN- 100 A -breaking capacity 25 KA - 01 No OUT GOING MCCB TPN- 32 A breaking capacity 16 KA - 05 Nos LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 400 Amps rated bus bar & comprising the following switch gear ( Zone 14 (FP-01- JCOs/OR Md Accn)) INCOMING MCCB 4 pole 250 A 36 KA breaking capacity- 01 No OUT GOING MCCB 4 pole 160A 25 KA breaking capacity- 02 Nos MCCB 4 pole 100 A 16 KA breaking capacity- 01 No LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 250 Amps rated bus bar & comprising the following switch gear (Zone 14 (FP-02- JCOs/OR Md Accn)) INCOMING MCCB 4 pole 160 A 25 KA breaking capacity- 01 No OUT GOING MCCB 4 pole 63 A 16 KA breaking capacity- 03 Nos MCCB TPN- 32 A breaking capacity 16 KA - 01 No LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 160 Amps rated bus bar & comprising the following switch gear ( Zone 14 (FP-03- JCOs/OR Md Accn) INCOMING MCCB 4 pole 100 A 25 KA breaking capacity- 01 No OUT GOING MCCB 4 pole 63 A 16 KA breaking capacity- 03 Nos LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 400 Amps rated bus bar & comprising the following switch gear ( Zone 14 (FP-04- JCOs/OR Md Accn)) INCOMING MCCB 4 pole 250A 36 KA breaking capacity- 01 No OUT GOING MCCB 4 pole 200A 25 KA breaking capacity- 02 Nos MCCB 4 pole 100 A 16 KA breaking capacity- 01 No LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 320 Amps rated bus bar & comprising the following switch gear ( Zone 14 (FP-05- JCOs/OR Md Accn)) INCOMING MCCB 4 pole 200A 25 KA breaking capacity- 01 No OUT GOING MCCB 4 pole 160A 25 KA breaking capacity- 02 Nos MCCB 4 pole 100 A 16 KA breaking capacity- 01 No LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 160 Amps rated bus bar & comprising the following switch gear ( Zone 14 (FP-06- JCOs/OR Md Accn)) INCOMING MCCB 4 pole 100 A 25 KA breaking capacity- 01No OUT GOING MCCB 4 pole 63 A 16 KA breaking capacity- 03 Nos LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 250 Amps rated bus bar & comprising the following switch gear ( Zone 14 (FP-07- JCOs/OR Md Accn)) INCOMING MCCB 4 pole 160 A 25 KA breaking capacity- 01No OUT GOING MCCB 4 pole 63 A 16 KA breaking capacity- 04 Nos MCCB TPN- 32 A breaking capacity 16 KA - 01 No LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 160 Amps rated bus bar & comprising the following switch gear ( Zone 14 (FP-08- JCOs/OR Md Accn)) INCOMING MCCB TPN- 100 A breaking capacity 25 KA- 01 No OUT GOING MCCB TPN- 32 A breaking capacity 16 KA - 03 Nos LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 160 Amps rated bus bar & comprising the following switch gear ( Zone 14 (FP-09- JCOs/OR Md Accn)) INCOMING MCCB 4 pole 100 A 25 KA breaking capacity- 01 No OUT GOING MCCB 4 pole 63 A 16 KA breaking capacity- 04 Nos LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 600 Amps rated bus bar & comprising the following switch gear ( Zone 14 (FP-10- JCOs/OR Md Accn)) INCOMING MCCB 4 pole 400A 36 KA breaking capacity- 01 No OUT GOING MCCB 4 pole 400A 36 KA breaking capacity- 02 Nos LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 600 Amps rated bus bar & comprising the following switch gear ( Zone 14 (FP-11- JCOs/OR Md Accn)) INCOMING MCCB 4 pole 400A 36 KA breaking capacity- 01 No OUT GOING MCCB 4 pole 250A 25 KA breaking capacity- 02 Nos MCCB 4 pole 100 A 16 KA breaking capacity- 01 Nos LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 160 Amps rated bus bar & comprising the following switch gear ( Zone 14 (FP-12- JCOs/OR Md Accn)) INCOMING MCCB 4 pole 100 A 25 KA breaking capacity- 01 No OUT GOING MCCB 4 pole 63 A 16 KA breaking capacity- 03 Nos LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 400 Amps rated bus bar & comprising the following switch gear ( Zone 14 (FP-13- JCOs/OR Md Accn)) INCOMING MCCB 4 pole 250 A 36 KA breaking capacity- 01 No OUT GOING MCCB 4 pole 63 A 16 KA breaking capacity- 06 Nos LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 320 Amps rated bus bar & comprising the following switch gear ( Zone 14 (FP-14- JCOs/OR Md Accn)) INCOMING MCCB 4 pole 200A 25 KA breaking capacity- 01 No OUT GOING MCCB 4 pole 100A 16 KA breaking capacity- 03 Nos LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 160 Amps rated bus bar & comprising the following switch gear ( Zone 14 (FP-15- JCOs/OR Md Accn)) INCOMING MCCB 4 pole 100A 25 KA breaking capacity- 01 No OUT GOING MCCB 4 pole 100A 16 KA breaking capacity- 02Nos MCCB TPN- 32 A breaking capacity 16 KA - 03 No LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 160 Amps rated bus bar & comprising the following switch gear ( Zone 14 (FP-16- JCOs/OR Md Accn)) INCOMING MCCB 4 pole 100 A 25 KA breaking capacity- 01 No OUT GOING MCCB 4 pole 63 A 16 KA breaking capacity- 02 Nos MCCB TPN- 32 A breaking capacity 16 KA - 04 No LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 100 Amps rated bus bar & comprising the following switch gear ( Zone 14 (FP-17- JCOs/OR Md Accn)) INCOMING MCCB 4 pole 63 A 25 KA breaking capacity- 01 No OUT GOING MCCB 4 pole 63 A 16 KA breaking capacity- 02 Nos MCCB TPN- 32 A breaking capacity 16 KA - 06 Nos LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 100 Amps rated bus bar & comprising the following switch gear ( Zone 14 (FP-18- JCOs/OR Md Accn)) INCOMING MCCB TPN- 63 A -breaking capacity 25 KA 01 No OUT GOING MCCB TPN- 32 A breaking capacity 16 KA - 06 Nos LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 160 Amps rated bus bar & comprising the following switch gear ( Zone 14 (FP-19- JCOs/OR Md Accn)) INCOMING MCCB 4 pole 100 A 25 KA breaking capacity- 01 No OUT GOING MCCB 4 pole 63 A 16 KA breaking capacity- 2 Nos MCCB TPN- 32 A breaking capacity 16 KA - 05 Nos LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 100 Amps rated bus bar & comprising the following switch gear ( Zone 14 (FP-20- JCOs/OR Md Accn)) INCOMING MCCB 4 pole 63 A 25 KA breaking capacity- 01 No OUT GOING MCCB 4 pole 63 A 16 KA breaking capacity- 02 Nos MCCB TPN- 32 A - breaking capacity 16 KA 05 Nos LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
All as per item Ser.No. 18.00 above but 100 Amps rated bus bar & comprising the following switch gear ( Zone 14 (FP-21- JCOs/OR Md Accn)) INCOMING MCCB TPN- 63 A - breaking capacity 25 KA -01 No OUT GOING MCCB TPN- 32 A - breaking capacity 16 KA - 05 Nos LED Phase indicator lamp with holder -1 Set (RYB) Note: All MCCB's shall be adjustable thermal & fixed magnetic release type, Ics=100%Icu

1

-

-

... More
Supply and fixing Hot press PVC molded (Fire Proof) junction box of size 180 mm x 100 mm x 60 mm, complete with two No. aluminium bus bar of size 100 mm x 30 mm x 05 mm for phase and neutral, mounted on insulators, front opening door, locking arrangement and fixing with suitable size clamp and nut and bolt on pole, Including connection of incomer and outgoing cable by G I nuts, bolts and washers of suitable size and proper lugs incl making holes in bus bar complete all as specified & directed.

129

-

-

... More
Supply and fix of cable joint kit for 11 kv grade cable for outdoor straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured aluminium conductor cable of size 95 sqmm complete all as specified & directed.

8

-

-

... More
M&L for earthing complete with galvanized steel earth plate electrode size 600 x 600 x 3.15 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized iron strip 20X3 mm earth lead by means of bolts, nuts, check nuts and washers of galvanized steel and GI pipe medium grade 20 mm dia bore for watering funnel with wire mesh. CI cover with frame, 32 mm dia GI pipe light grade for earthing electrode protection, PCC chamber pit with PCC (1:3:6 ) type C- 1, 40 mm thick precast RCC M-25 (Design Mix) cover reinforce with 8 mm dia TMT bars @ 10 cm c/c both ways and lifting handle, excavation and earth work all as shown in electrical plate No 3 of SSR Part-I (2009) connected to earthing test point all as specified or indicated including testing on completion. Note:- (i). Excavation, returning filling and removing of surplus soil is deemed to be included in the unit rate. (Description continue from last item) (ii) Cost of PCC pit, RCC Pit cover with funnel & wire mesh, water pipe, test point is demmed to be included in the unit rate in addition to Item No.1(a) to 1(e) of premeable (Notes) under sub-heading earthing, specified in SSR Part-II. No.1(a) to 1(e) of premeable (Notes) under sub-heading earthing, specified in SSR Part-II. (iii) The unit rate also includes the cost of GI earth lead and GI pipe for protection of earth strip up to 7.5 metre (any variation in length shall be adjusted through deviation order). iv) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.

6

-

-

... More
Supply and fix cable end joint kit for 11 kv grade cable for outdoor termination, cold shrink type joint complete for jointing material and accessories suitable for 3 core XLPE, armoured aluminium conductor cable of size 95 sqmm complete all as specified & directed.

6

-

-

... More
Supply and fix HT 11 KV, outdoor type gang operated air-break switch suitable for horizontal or vertical mounting fixed/rotating type complete with drop out fuse having 12 insulators rating upto 200 Amps complete all as specified & directed.

3

-

-

... More
Supply and fix cable end joint kit for 1.1 kv grade cable for outdoor termination, heat shrink type joint complete for jointing material and accessories suitable for 3.5 / 4 core XLPE, armoured aluminium conductor cable of size 300 to 400 sqmm complete all as specified & directed.

3

-

-

... More
Supply and fix PVC insulated, PVC sheathed cable, galvanized steel strip or wire armoured with Stranded copper conductor 1.5 sqmm and 03 core for connecting security lights to PVC junction box complete complete all as specified & directed.

726

-

-

... More
Excavation in trenches not exceeding 1.5 mtrs wide & not exceeding 1.5 mtr in depth in soft or loose soil & getting out complete all as specified & directed.

3850

-

-

... More
Removing excavated material not exceeding 50mtr & depositing where direceted at a level not exceeding 1.5mtrabove the ground level complete all as specified & directed.

1650

-

-

... More
Returning , filling in spreading, levelling, watering & well ramming in layers not exc 25cm thick complete all as specified & directed.

2150

-

-

... More
M&L for precast concrete cable cover class LV, type I, flat size 250mm x 150mm x 40mm for cable protection in trenches complete all as specified and directed.

92500

-

-

... More
M&L for precast concrete cable cover class HV, type I, flat size 300mm x 180mm x 40mm for cable protection in trenches complete all as specified and directed.

24500

-

-

... More
M&L for sand fillitng with clean dry fine sand unwashed including gently punning around cablkes in trenches for cable protection (8 cm below cable & 15 cm above cable) complete all as specified and directed. Note: Compacted/punned thickness shall be measured & Paid

1294

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.