Directorate General Defence Estates Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Directorate General Defence Estates - DGDE Tender
Civil And Construction
Building Construction
Eprocure
Opening Date11 Oct 2024
Closing Date22 Oct 2024
Tender Amount₹ 1,27,50,000
Costs
EMD
₹ 2,55,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_DGDE_679141_1Bid Award Id
ViewTender No
CEO/ALLD/ ENGG/2024-25/CGH HALLTender Authority
Directorate General Defence Estates ViewPurchaser Address
-Website
http://defproc.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Construction of new hall at First Floor of Cantonment General Hospital, New Cantt, Allahabad
BOQ Items
FORM WORK TO FLOOR BEAMS FOR ROUGH FINISHED SURFACES OF CONCRETE WITH FLAT PLATE as per MES SSR Item No. 7010
472
-
-
FORM WORK TO FLOOR SLABS FOR ROUGH FINISHED SURFACES OF CONCRETE WITH FLAT PLATE as per MES SSR Item No. 7006
1023
-
-
R.C.C. M-25 IN COLUMN (FOUNDATION TO ROOF SLAB) as per MES SSR Item No. 4058
21
-
-
R.C.C. M-25 IN LINTEL BEAM as per MES SSR Item No. 4057
2.76
-
-
R.C.C M-25 IN CHAJJA as per MES SSR Item No. 4056
3.23
-
-
R.C.C. M-25 IN SLAB BEAM / ROOF BEAMS as per MES SSR Item No. 4057
45.2
-
-
R.C.C. M-25 IN ROOF SLABS as per MES SSR Item No. 4055
82.17
-
-
Brickwork with first class bourned clay bricks, straight or curved on plan exc 6m mean radius, built in 1:6 cement mortar as per MES SSR Item No. 05019
282.44
-
-
MS TMT BAR 10MM DIA AND OVER CUT TO LENGTH, BENT TO SHAPE AS REQUIRED AND BINDING WITH MS WIRE NOT LESS THAN 0.09MM DIA ANNEALED as per MES SSR Item No. 10034
10051.51
-
-
REINFORCEMENT IN STIRRUPS WITH TMT BAR 8 TO 10MM as per MES SSR Item No. 10036
8080.66
-
-
0.90 MM DIA MILD STEEL SOFT DRAWN BINDING WIRE, ANNEALED as per MES SSR Item No. 10114
60.31
-
-
WASTAGE OF STEEL as per MES SSR Item No. 10034
80.81
-
-
M & L FOR LAYING OF 25MM THK. P.C.C 1:2:4 AT SUB BASE OF FLOORS as per MES SSR Item No. 13036
529.92
-
-
RENDER CEILING PLASTER 5MM THICK IN (1:3) CEMENT SAND MORTAR ON SOFFITS OF SLAB / SUNSHADE as per MES SSR Item No. 14001, 14004, 14005
1870
-
-
INTERNAL PLASTERING 15 MM THICK WITH 1:6 RATIO as per MES SSR Item No. 14001, 14005
2398.05
-
-
M & L FOR EXTERNAL 20 MM TH CEMENT PLASTER IN TWO LAYERS OF 10 MM & 10MM EACH WITH CM (1:4) APPLYING WPC IN OUTER LAYER as per MES SSR Item No. 14001, 14004, 14005
450.38
-
-
M& L FOR FIXING OF 20MM THK MACHINE CUT POLISHED KOTA STONE OVER 20MM THK SCREED BED IN CM 1:6 FOR FLOORING as per MES SSR Item No. 13013+14009 & 14010
168.72
-
-
M& L FOR FIXING OF SKIRTING 100 MM HIGH AND STEPS RISERS 20 MM MACHINE CUT POLISHED KOTA STONE (MAT- CHING WITH FLOOR) OVER 10 MM TH BACKING COAT IN CM (1:3) as per MES SSR Item No. 13015+14009-14010
4.54
-
-
M& L FOR FIXING OF 600 X 600 MM & 10 MM THICK VITRIFIED TILES OVER 15 MM TH SCREED IN CM (1:6) as per MES SSR Item No. 13086+14009
393.81
-
-
M& L FOR FIXING OF 600 X 600 MM & 10 MM THICK VITRIFIED TILES OVER 10 MM TH BACKING COAT IN CM (1:3) in SKIRTING as per MES SSR Item No. 13086 + 14009-14010
18.93
-
-
M& L FOR FIXING Non Skid Ceramic colour tiles 7 to 8 mm thick, area of each tile exc. 0.11 sqm but n. exc 0.18 Sqm (400x400) OVER 15 MM TH SCREED IN CM (1:6) as per MES SSR Item No. 13083+14009
18.62
-
-
M& L FOR FIXING OF COLOURED GLAZED CERAMIC TILES OF SIZE 300X450 7-8 MM THK ON WALLS SURFACE OVER 10 MM THK CEMENT SCREED IN CM 1:3 FOR DADO as per MES SSR Item No. 13081+14010
41.12
-
-
20 MM THICK GRANITE SLAB WITH ROUNDED EDGE OVER COOCKING PLATFORMS & COUNTERS as per MES SSR Item No. 13023
10.97
-
-
Proving & fixing 2mm Viny Trendo Flooring in OT laid over CC floor
99.68
-
-
Providing & fixing Gerflor Mural plus Wall covering on OT walls over plain smooth plaster
1380
-
-
M & L FOR APPLYING THREE COATS OF WHITE WASH (INTERNAL CEILING AREA ) T1 as per MES SSR Item No. 15002+15007
1586.57
-
-
M & L FOR APPLYING TWO COATS OF OIL BOUND DISTEMPER OVER A COAT OF PRIMER, OVER WALL PUTTY (putty to be paid separately) (CEILING SURFACE) as per MES SSR Item No. 15002+15005+15009
1586.57
-
-
M & L FOR APPLYING TWO COATS OF OIL BOUND DISTEMPER OVER A COAT OF PRIMER, OVER WALL PUTTY (putty to be paid separately) (INTERNAL WALL SURFACE) as per MES SSR Item No. 15001+15005+15009
2398.05
-
-
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) (Weather proof paint over a coat of putty- to be paid separately) EXTERNAL WALL SURFACE as per MES SSR Item No. 15001, 15014F
450.38
-
-
M & L FOR A COAT OF WALL PUTTY as per MES SSR Item No. 14016
4435.02
-
-
APP BASED POLYMERIC MEMBRANE OVER BITUMINOUS PRIMER ( ROOF) as per MES SSR Item No. 11068
529.92
-
-
ROOF PLASTERING OF 15 MM THICK IN CM 1:4 FOR WATER PROOFING OF ROOF as per MES SSR Item No. 14001+14004
529.92
-
-
APPLYING EVENLY A PRIMING/TACK COAT WITH BITUMINOUS PRIMER AT 10 KG PER 10 SQ METRE WITH PAVING BITUMEN as per MES SSR Item No. 20016
52.99
-
-
Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and with powder coating as per MES SSR Item No. 10087+10088
216.95
-
-
Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) as per MES SSR Item No. 10091
28.77
-
-
ANODISED ALUMINIUM DOOR SHUTTER, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminumsnap beading screws etc. complete all as specified as per MES SSR Item No. 10089
29.39
-
-
SUPPLY AND FIXING 5.5mm Sheet glass in windows and ventilatores , ordinary quality and glazing with oil putty in square not exceeding 0.5 sq. m in eachpane as per MES SSR Item No. 16001
28.77
-
-
SUPPLY AND FIXING OF STEEL GRILL 10MM DIA BAR FOR WINDOW / VENTILATOR and steel railing on staircase & Balconies as per MES SSR Item No. 10046
287.69
-
-
S & F of 12mm thick pre laminated particle board fixed without rubber gasket as per MES SSR Item No. 12047
14.79
-
-
SUPPLY AND FIXING OF M.S 100 MM BUTT HINGES as per MES SSR Item No. 9028
221
-
-
SUPPLY AND FIXING OF TOWER BOLT 200 MM as per MES SSR Item No. 9004
55
-
-
SUPPLY AND FIXING OF TOWER BOLT 150 MM as per MES SSR Item No. 9004
55
-
-
SUPPLY AND FIXING OF STEEL BOW / D TYPE HANDLE 150MM as per MES SSR Item No. 9083
113
-
-
SUPPLY AND FIXING OF STD FI. HOLD FAST as per MES SSR Item No. 9114
331
-
-
SUPPLY AND FIXING OF ALDROP BOLT 19mm Ø 300MM LONG as per MES SSR Item No. 9019
55
-
-
Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed as per MES SSR Item No. 9154
6
-
-
M & L FOR Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed alusters; walk ways; M.S railings as per MES SSR Item No. 10007
287.69
-
-
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement as per MES SSR Item No. 1009A
347.76
-
-
SUPPLY OF CUPBOARD CB3
62.6
-
-
Material and labour for modular point wiring complete with 1.5 Sqmm single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with multistranded copper conductor with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheated copper conductor cable FR-LS (ISI markd) as earth continuity conductor connected to common earth dolly , modular sheet steel sunken terminal box suitable for modular switch/ fittings concealed in walls, with modular back plate, top cover for housing switches, socket outlets, fan regulators etc duly earthed for the following :-
-
-
-
One Light point controlled by one switch 5/6 Amps as per MES SSR Item No. 19305
4
-
-
One Ceiling / Exhaust Fan point controlled by one switch 5/6 Amps as per MES SSR Item No. 19305
17
-
-
One socketout let point 5/6 Amps on same board as per MES SSR Item No. 19311
11
-
-
One switch socket outlet point 5/6 Amps on independent boardmas per MES SSR Item No. 19313
86
-
-
One call bell/buzzer point controlled by one bell push as per MES SSR Item No. 19317
4
-
-
All as per item No:- 5 hereinbefore but one socket outlet 15 Amps point modular on independent board with 2.5 Sqmm single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) multistranded with 2.5 Sqmm PVC insulated multistranded unsheated copper conductor cable FR-LS (ISI markd) as earth continuity conductor as per MES SSR Item No. 19314
62
-
-
S & F Modular switch, single pole, one way, 6 Amp, 1 Module, 230 volt, ISI marked complete as per MES SSR Item No. 19389
97
-
-
S & F Modular switch, single pole, one way, 16 Amp, 1 Module, 230 volt, ISI marked complete as per MES SSR Item No. 19391
62
-
-
Supply and fixing Modular bell push, one way, 6 Amp, 1 Module, 230 volt, ISI marked complete as per MES SSR Item No. 19395
4
-
-
Supply and fixing Modular shuttered Socket outlet 5 Pin, 6 Amp, 2 Module, 230 volts, ISI marked as per MES SSR Item No. 19399
97
-
-
Supply and fixing Modular shuttered Socket outlet 6 Pin, 6/16 Amp, 2 Module, 230 volts, ISI marked as per MES SSR Item No. 19400
62
-
-
Supply and fixing of call bell ding dong type AC Single pole 220/240 Volts, surface type complete as per MES SSR Item No. 19396
4
-
-
Supply and fixing ceiling rose, bakelite/polycarbonate, isolated body, three terminals, 65 mm (ISI marked) complete as per MES SSR Item No. 19469
21
-
-
Supply and fixing of LED 20W Surface /Suspended and wall mounted LED batten, CRCA housing provided for efficient heat dissipation with polycarbonate diffuser & built-In electronic driver having THD10%. with required accessories complete in all respect.
2
-
-
Supply and fixing 10W LED ADORE PLUS 10W B22 CDL 2 STAR LAMP base cap B22 with required accessories complete in all respect.
2
-
-
Supply and fixing 10W Surface and wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with industrial grade heavy duty driver having THD10%. with required accessories complete in all respect.
2
-
-
Supply and fixing 36W IP65, dust free & zero maintenance 2x2 LED Clean Room Top Opening luminaire for hygienic facilities. with required accessories complete in all respect.
42
-
-
SITC of High efficacy 18W Surface mounted Downlight with Aluminium (99% Purity) Sink, available in Sqaure shape. PC diffuser in white powder coated finish with built in electronic low THD (10%) LED driver complete in all respect.
28
-
-
Supply and fixing Ceiling Fan Energy Efficient (BLDC) , Star rated, AC 230 Volts single phase 1200 mm sweep, 26-30 watt, with three blade complete with all accessories including MS Hook,down rod, Nuts, Bolts and washer for hanging arrangement without Remote including provision of 3 core of size 0.5 Sqmm (16/0.2 mm) copper cable from ceiling rose to fan complete all as specified.
16
-
-
Supply and fixing stepped type modular electronic fan regulator 120 watt 2 module suitable for 1200/1400 mm sweep energy saving fans,ISI marked complete as per MES SSR Item No. 19401
16
-
-
Supply and fixing exhaust fan with louvers 300 mm sweep , AC single phase 240 volts, 50Hz and connecting up complete including built in louvers and provision of cable 3 core of size 0.5 Sqmm (16/0.2 mm) from ceiling rose to fan as specified and directed.
2
-
-
Material and labour for submain wiring for main DBs to Sub DBs/Plug & Sockets with PVC insulated unsheathed FR-LSH cable 1100 volts grade of size 4 Sqmm x 2 run alongwith earth continuity wire connected from main earth of size 2.5 Sq mm x 1 run, ISI marked multi stranded copper conductor single core cable drawn in and including non-metallic rigid PVC medium grade conduit and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc of size 25 mm as requried as specified and as directed.
Note : Two runs of 4 sqmm conductor for main and one run of 2.5 sqmm conductor as earth wire with PVC conduit shall be measured as one unit length.Connections of cables with MCBs or bus bars shall be done with appropriate size brass/copper thimbles as per MES SSR Item No. 19509
2525.4
-
-
Material and labour for submain wiring for main DBs to Sub DBs with PVC insulated unsheathed FR-LS cable 1100 volts grade of size 6 Sqmm x 2 run alongwith earth continuity wire connected from main earth of size 4 Sq mm x 1 run, ISI marked multi stranded copper conductor single core cable drawn in and including non-metallic rigid PVC medium grade conduit and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc of size 25 mm as requried. Note : Two runs of 6 sqmm conductor for main and one run of 4 sqmm conductor as earth wire with PVC conduit shall be measured as one unit length. Connections of cables with MCBs or bus bars shall be done with appropriate size brass/copper thimbles as per MES SSR Item No. 19510
41.4
-
-
Material and labour for submain wiring with PVC insulated unsheathed FR-LS cable 1100 volts grade of size 10 Sqmm x 4 run alongwith earth continuity wire connected from main earth of size 6 Sq mm x 2 run, ISI marked multi stranded copper conductor single core cable drawn in and including non-metallic rigid PVC medium grade conduit and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc of size 40 mm as requried. Note : Four runs of 10 sqmm conductor for main and two run of 6 sqmm conductor as earth wire with one run PVC conduit shall be measured as one unit length. Connections of cables with MCBs or bus bars shall be done with appropriate size brass/copper thimbles as per MES SSR Item No. 19517
372.6
-
-
Material and labour for submain wiring with PVC insulated unsheathed FR-LS cable 1100 volts grade of size 16 Sqmm x 4 run alongwith earth continuity wire connected from main earth of size 10 Sq mm x 2 run, ISI marked multi stranded copper conductor single core cable drawn in and including non-metallic rigid PVC medium grade conduit and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc of size 40 mm as requried. Note : Four runs of 16 sqmm conductor for main and two run of 10 sqmm conductor as earth wire with one run PVC conduit shall be measured as one unit length. Connections of cables with MCBs or bus bars shall be done with appropriate size brass/copper thimbles as per MES SSR Item No. 19518
82.8
-
-
Supplying and fixing 6 way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.
2
-
-
Supplying and fixing of 6 ways surface/ recess mounting, vertical type, 415 V, TPN MCCB distribution board of sheet steel, dust protected, duly powder painted, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required .
2
-
-
Supplying and fixing 6 way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required as per MES SSR Item No. 19456
2
-
-
Supplying and fixing 4 way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required as per MES SSR Item No. 19456
2
-
-
Supply and fixing MCCB FP 63 Amps, 16 kA breaking cap with thermal magnetic release. Make - L&T or equivallent make of Havells/Legrand as per MES SSR Item No. 19433
2
-
-
Supply and fixing MCB Four pole (FP) 63 amps, 10 KA,‘C’ curve, 415 volts. ISI marked complete all as specified.
2
-
-
Supply and fixing MCB Four pole (FP) 40 amps, 10 KA,‘C’ curve, 415 volts. ISI marked complete all as specified.
2
-
-
Supply and fixing MCB Single pole and neutral (SPN) 32 amps, 10 KA,‘C’ curve, 240 volts. ISI marked complete all as specified.
2
-
-
Supply and fixing MCB Single pole (SP), 6 to 32 amps, 240 volts, ‘C’ curve, 10 KA ISI marked complete all as specified.
97
-
-
Supply and fixing Dummy (Blanking) Plate for MCB DB ISI marked complete all as specified.
7
-
-
S&F Metal plug and socket assembly, Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20 Amp 'C' curve fixed flush to wall as per MES SSR Item No. 19452
23
-
-
Rigid non-metallic 25 MM DIA PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc as per MES SSR Item No. 19520
331.2
-
-
Materials and labour for Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised earth lead wire 4.0 mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 15 mm bore (medium grade) and other end connected to earthing test point including providing funnel and watering pipe 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work, excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including test point and testing on completion as per MES SSR Item No. 19471
5
-
-
Materials and labour for Extension of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire as per MES SSR Item No. 19481
165.6
-
-