Dakshinanchal Vidyut Vitran Nigam Limited Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Dakshinanchal Vidyut Vitran Nigam Limited - DVVNL Tender
Electrical and Electronics
Eprocure
Opening Date26 Jul 2024
Closing Date9 Aug 2024
Tender AmountRefer Documents
Costs
EMD
₹ 37,000Document Cost
₹ 3,000Tender Fee
Refer Documents
Summary
As Per Tender Document
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_DVVNL_941329_1Bid Award Id
ViewTender No
03/EWC(K)/2024-25Tender Authority
Dakshinanchal Vidyut Vitran Nigam Limited ViewPurchaser Address
-Website
http://https://www.dvvnl.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Structure of PI with plinth & foundation
2
-
-
Structure of L.A with plinth & foundation
1
-
-
PG Clamp for DOG to DOG
174
-
-
Chemical pipe earthing
2
-
-
Control cable (copper) 4x2.5
200
-
-
Control cable (copper) 2x2.5
200
-
-
Stone pad
206
-
-
Top Channel 125x65with clamp 3200 mm
36
-
-
Bracing angle 65x65x6with clamp 4300 mm
36
-
-
E clamp for 33 KV
78
-
-
33 KV Number plate with Clamp with nut & bolt
196
-
-
33 KV Danger board with clamp, nut & bolt
196
-
-
Alluminium Binding Wire
106
-
-
Barbed wire
412
-
-
Bolt, Nut & Washer
238
-
-
MS Dropper Channel 100x50x6 mm with holding clamp, bolt, Nut & washer.
26
-
-
Al. paint
71
-
-
Redoxide paint
71
-
-
33 KV X-Arm holding Clamp with nut & bolt
160
-
-
F Clamp with nut & bolt
160
-
-
Channel 100x50x6mmx2.5 M with Clamp
12
-
-
Clamp for fixing Cable on channel of double poles
24
-
-
Eye bolt
36
-
-
Turn Buckle
36
-
-
33 KV M.S.guarding angle
18
-
-
Safe Carriage following item from any store center & local authorized supplier (under juridiction of DVVNL) to site store with loading unloading at both end respectively
-
-
-
ACSR Dog Conductor
26.9
-
-
33 KV LA
3
-
-
33KV Line Isolator
1
-
-
33 KV VCB
1
-
-
CT 400/200/1A
3
-
-
33 KV Control Panel for single feeder
1
-
-
33KV Post Insulator
6
-
-
PCC Pole 9 Mtr long
135
-
-
V-type x-arm for 33KV
160
-
-
33 KV Composite Polymer Pin insulators
558
-
-
Earthing of Pole by MS earthing rod of 20x2500 mm & 6 SWG earthing wire etc.)
206
-
-
33 KV Polymer DISC INSULATOR (B&S) 70KN
108
-
-
33 KV Disc fitting B&S 70 KN
108
-
-
Stay set complete (GI Stay Rod 20x1800, Stay Ins., stay wire 7/8 SWG 10 Kg, bolt, nut & washer with Grouting)
176
-
-
STP 13meter long SP-72
5
-
-
STP 11meter long SP-55
66
-
-
G.I.Wire 6swg
342
-
-
G.I.Wire 10swg
126
-
-
33 KV XLPE Cable 3×300mm sq.
960
-
-
M.S.angle 75x75x6 ,2.5m long
18
-
-
Eye bolt
36
-
-
Turn buckle
36
-
-
Structure of L.A with plinth & foundation
1
-
-
Structure of Line Isolator with plinth & foundation
1
-
-
Structure of 33 KV Post Insulator with Plinth & foundation
2
-
-
Structure of CT with Plinth & foundation
1
-
-
chemical pipe earthing
2
-
-
PG Clamp for DOG to DOG
174
-
-
Control cable (copper) 4x2.5
200
-
-
Control cable (copper) 2x2.5
200
-
-
F Clamp with nut & bolt
160
-
-
X-Arm holding Clamp with nut & bolt
160
-
-
33 KV Number plate
196
-
-
Danger board with clamp
196
-
-
Barbed wire
412
-
-
Bolt, Nut & Washer
238
-
-
Alluminium Binding Wire
106
-
-
Top Channel 125x65with clamp
36
-
-
Bracing angle 65x65x6with clamp
36
-
-
E clamp for 33 KV
78
-
-
MS Angle for Dropper 100x50x6 mm with holding clamp, bolt, Nut & washer.
26
-
-
Al. paint
71
-
-
Redoxide paint
71
-
-
Channel 100x50x6mmx2.5 M with Clamp
12
-
-
Clamp for fixing Cable on channel of double poles
24
-
-
GI Pipe 6" dia
36
-
-
HDPE Pipe
600
-
-
33 KV Cable jointing kit for 3×300mm sq. XLPE Cable out door
12
-
-
24 Volt Battery set and charger with cabinet complete
1
-
-
Terminal Gantry
1
-
-
Erection/Fixing/Laying Work of above materials
-
-
-
Digging of trenches and flling earth, Dressing& ramming for laying cable with sand& bricks Arrangement.
120
-
-
Laying of 33 KV 3x300 sq.mm XLPE Double Ckt cable in digged trench
120
-
-
Laying of 33 KV 3x300 sq.mm XLPE cable with HDPE Pipe by HDD Method
600
-
-
Mounting of 33 KV 3x300 sq.mm XLPE cable through G.I Pipe on D.P, mounting on poles with proper claming
120
-
-
Making outdoor joints of 33 KV 3x300 mm2.
12
-
-
Making all control cable connection in C.T., VCB mechanism, C.T. Junction Box, Control relay panel D.C. Battery Charger, ACDB Transformer indication board 11KV switchgear including proper termination ferruling and dressing with related work
1
-
-
33 KV LA on structure
3
-
-
33 KV CT on structure
3
-
-
33 KV L I on structure
1
-
-
33 KV post insulator on structure
6
-
-
33 KV VCB pannel
1
-
-
33 KV single Feeder control pannel at control room
1
-
-
9 Mtr long PCC Poles
135
-
-
11 Mtr long STP Poles
66
-
-
13 Mtr long STP Poles
5
-
-
Concreting of 9 Mtr long PCC Poles
135
-
-
concreting of 11 Mtr long STP Poles
66
-
-
Concreting of 13 Mtr long STP Poles
5
-
-
33 KV V-type X-arm
160
-
-
X-arm holding clamp
160
-
-
33 KV F-clamp
160
-
-
33 KV composite pin Insulator
558
-
-
33 KV Polymer Disc Insulator
108
-
-
33 KV Disc fitting
108
-
-
24 Volt Battery set and charger with cabinet complete
1
-
-
Terminal Gantry with plinth and foundation
1
-
-
M.S Top channel 125x65x6 mm 3200 mm long with clamp
36
-
-
M.S bracing angle 65x65x6 4300 mm long with clamp
36
-
-
Stone pad
206
-
-
Erection Barbed wire
412
-
-
Bolt, Nut & washer
238
-
-
Aluminium binding wire 6 swg
106
-
-
MS angle dropper 100x50x6 mm holding clamp, bolt, Nut & washer
26
-
-
GI Pipe 6" dia on D/p
36
-
-
33 KV Danger Plate with clamp, Nut& bolt
196
-
-
33 KV Number Plate with clamp, Nut& bolt
196
-
-
Earthing of Pole by MS earthing rod of 20x2500 mm & 6 SWG earthing wire etc.)
206
-
-
Stay Set Complete (Stay rod 20x1800mm, stay wire 10Kg, stay clamp, bolt & nut, stay Ins., with Grouting)
176
-
-
ACSR DOG conductor
26.9
-
-
PG clamp for DOG to DOG
174
-
-
Chemical Pipe Earthing for T/f , C/T ,VCB earthing etc
2
-
-
Painting of all structure
1
-
-
Control cable 4x2.5sqmm in trench with sand
200
-
-
Control cable 2x2.5sqmm in trench with sand
200
-
-
Plinth & foundation of L.A structure
1
-
-
Plinth & foundation of P.I structure
2
-
-
Plinth & foundation of L I structure.
1
-
-
Plinth & foundation of C.T structure
1
-
-
VCB with plinth & foundation.
1
-
-
Earthing of L A structure with G I Strip 50x6 with chemical pipe earthing and Earthmat
1
-
-
Earthing of C.T structure with G I Strip 50x6 with chemical pipe earthing and Earthmat
1
-
-
Earthing of VCB structure with G I Strip 50x6 with chemical pipe earthing and Earthmat
1
-
-
Earthing of P.I structure with G I Strip 50x6 with chemical pipe earthing
2
-
-
Earthing of L I tructure with G I Strip 50x6 with Earthmat
1
-
-
Al. Paint
71
-
-
Red oxide Paint
71
-
-
E clamp
78
-
-
Channel 100x50x6 mm 2.5 m
12
-
-
M.S.gaurding angle 75x75x6 ,2.5m long
18
-
-
Eye bolt
36
-
-
Turn buckle
36
-
-
G.I. wire 6 SWg
342
-
-
G.I. wire 10 SWg
126
-
-
Evaluation Notes How It Works ?