If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search &amp; bid for etender UP.

Bharat Sanchar Nigam Limited - BSNL Tender

Works
Electrical and Electronics
Eprocure
Opening Date16 Nov 2024
Closing Date28 Nov 2024
Tender Amount₹ 26,98,429 
Notes
Download

Costs

Summary

Servicing And Minor Repairing Of Dg Sets I/c Providing Battery And Changeover Switch At Various Bts/hub Sites

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
[d] above 32.5 KVA up to 45 KVA

10

-

-

... More
[e] above 45 KVA and upto 62.5 KVA

4

-

-

... More
Sub Head-II ( Repairing Works of DEA Sets) :: Replacement of faulty / defective spare parts / components/ accessories of existing DG sets i/c dismantling / disconnecting the faulty /defective ones, fixing and connection of new ones, testing and commissioning etc. complete as required.( Make- Recommended by manufacturer/ BSNL makes only) [a] 1x25 sqmm flexible Multi core cu conductor PVC insulated Battery Leads (Flexible) of length not less than 0.6 Meters with two nos terminals .

20

-

-

... More
[b] Flexible wire braided fuel pipe of 19 mm dia for the connection of fuel line connection ( inlet and outlet ) complete as required at site.

50

-

-

... More
[c] Banjo bolts with washer

50

-

-

... More
[d] Suitable size belt

50

-

-

... More
Providing of maintenance free New Lead acid Batteries of following types / rating complete with first fill of electrolyte & first charging i/c testing and commissioning at site complete as reqd. [a] 88Ah, 12 volt maintenance free Battery (M/s Exide FXPO-XP880 or Equivalent of BSNl approved. Make)

50

-

-

... More
[b] 130 Ah, 12 volt maintenance free Battery (M/s Exide FXPO-XP1300 or Equivalent of BSNL approved Make)

20

-

-

... More
[c] 150 Ah, 12 volt maintenance free Battery (M/s Exide FXPO-XP1500 or Equivalent of BSNL approved. Make)

10

-

-

... More
Repairing of following items of EA set i/c replacement of faulty parts, making connection, testing etc complete as reqd. [a] Starting Self 12v up to 25 KVA

10

-

-

... More
[b] Starting Self 12V, 32.5 to 62.5 KVA

10

-

-

... More
[c] Charging Alternator

10

-

-

... More
[d] Repairing and Cleaning of Engine Radiator up to 62.5 KVA EA Set etc complete as required.

10

-

-

... More
Repairing and servicing of FIP i/c replacement of faulty components , tresting , calibration etc. complete as reqd. [a] Up to 25 KVA EA Set

10

-

-

... More
[b] From 30 KVA to 62.5 KVA EA Set

4

-

-

... More
Re-winding of alternator with "H" class insulated copper wire and "H" class insulated material (Paper, Varnish ,appoxi base hardner) i/c replacement of diodes, petty repairing , testing, dismantling and realignment, transportation upto work shop, loading /unloading etc. complete as required. (Note: The dismantled burnt copper winding will be the property of the firm, so the rates to be quoted accordingly) [a] Up to 25 KVA EA Set

5

-

-

... More
[b] From 30 KVA to 62.5 KVA EA Set

2

-

-

... More
S/F of following capacity rating four pole on Load change over switch in steel enclosure capable of working 415/500 V ,AC 23 Duty i/c drilling hole on the board, making connection, earthing the body etc. as reqd. Make: HPL SOCOMAC or SS make) [a] 63 Amp Four pole on load

10

-

-

... More
[b] 125 Amp Four pole on load

4

-

-

... More
Supplying & fixing of three Phase AVR suitable for voltage regulation in DG set upto 62.5 KVA Capacity EA set i/c testing etc. complete as reqd.

10

-

-

... More
Shifting of following capacity DG set from one site to another i/c dismantling , loading / unloading and installation of DG set at new location etc. complete as reqd . ( Upto 30 Km distance ) [a] Upto 25 KVA DG set

4

-

-

... More
[b] Above 25 KVA to 62.5 KVA EA Set

4

-

-

... More
[c] Extra per Km. charges for distance more than 30 Km

300

-

-

... More
Supply and laying of one number 4x16 Sqmm XLPE insulated and PVC sheathed power cable of 1.1 KV grade of following size aluminium conductor armored cable in the following manners:- [a] In the existing masonry open duct/ surface/ wall as required.

300

-

-

... More
[b] Direct in CC floor i/c cutting the CC floor and making good the damages etc. complete as required.

50

-

-

... More
Supply and laying of one number 3½ x50 Sqmm XLPE insulated and PVC sheathed power cable of 1.1 KV grade of following size aluminium conductor armored cable in the following manners:- [a] In the existing masonry open duct/surface /wall as required.

100

-

-

... More
[b] Direct in CC floor i/c cutting the CC floor and making good the damages etc. complete as required.

50

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. [a] 4x16 sq. mm

20

-

-

... More
[b] 3½ X 50 sq. mm

16

-

-

... More
Making arrangement of fuel for minimum 30 minutes run of EA set (Not less than 5.00 Ltrs) i/c cartage, container and filling the fuel in existing tank etc as complete as required at site. (This item executed only those sites where fuel not made available by the BSNL authorities)

40

-

-

... More
SH-III ( Buy back of old Lead acid batteries) :: Less (Buy back ) price for 12 Volt old existing unsevicable battery irrespective of make and model available at site. [a] AH capacity up to 110 AH

15

-

-

... More
AH Capacity Above 110 AH & up to 130 AH

10

-

-

... More
AH capacity Above 130 AH & Up to 150 AH

2

-

-

... More
SH-IV ( Visit Charges) :: Visit charges to attend fault of DEA Set on call basis/ complaint basis on behalf of written Job order from SDE(E) concerned for different TE /BTS sites under jurisdiction including attending the minor faults involving no material and submit detailed report for major fault to the Engineering -In-charge i/c fare charges to visit the site from HQ etc complete as reqd. Note:- (1) Visit Charges are not payable, if cost of work executed at particular site is beyond Rs 5000/-. (2). The Charges shall be paid only subject to submission of detailed site visit report in Job Order along with bill for sites where servicing / major repairing work not carried out by agency. (3). Charges shall be paid proportionately to attend the complaints e.g. 3 Sites for visit up to 30 KM's on a route, 2 Sites for visit more than 30 KM & Up to 60 KM on a route and 1 Site for visit beyond 60 KM from HQ . (4) Visit charges shall be allowed only once during the currency of contract/once in a year whichever is earlier for a particular sites/site as applicable.

40

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.