Banaras Hindu University Tender

... More
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of etender.up.nic.in - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.

Banaras Hindu University - BHU Tender

Works
Eprocure
Opening Date30 Jan 2019
Closing Date6 Feb 2019
Tender Amount₹ 4,99,354 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
…do….(1.14.2) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

500

-

137

... More
…do….(1.14.3) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire

700

-

168

... More
…do….(1.14.4) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire

30

-

227

... More
…do….(1.14.5) 2 X 10 sq. mm + 1 X 6 sq. mm earth wire

20

-

299

... More
…do….(1.14.6) 2 X 16 sq. mm + 1 X 6 sq. mm earth wire

50

-

408

... More
…do….(1.14.10) 4 X 10 sq. mm + 2 X 6 sq. mm earth wire

1

-

536

... More
…do….(1.14.11) 4 X 16 sq. mm + 2 X 6 sq. mm earth wire

1

-

733

... More
(1.20) Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. (1.20.1) 20 mm

10

-

126

... More
(1.24 ) Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (1.24.1) 5/6 amps switch

30

-

84

... More
….do…(1.24.2) 2 way 5/6 amps switch

1

-

99

... More
….do…(1.24.3) 15/16 amp switch

30

-

114

... More
….do…(1.24.4) 3 pin 5/6 amp socket outlet

30

-

81

... More
….do…(1.24.5) 6 pin 15/16 amp socket outlet

30

-

153

... More
…...do….(1.24.8) Bell push

2

-

114

... More
(1.25) Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

12

-

288

... More
(1.26) Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

20

-

24

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. (1.27.1) 1 or 2 Module (75mmX75mm)

2

-

175

... More
…do….(1.27.3) 4 Module (125mmX75mm)

2

-

205

... More
…do….(1.27.4) 6 Module (200mmX75mm)

2

-

258

... More
…do….(1.27.5) 8 Module (125mmX125mm)

30

-

297

... More
…do….(1.27.6) 12 Module (200mmX150mm)

2

-

344

... More
(2.3) Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (2.3.3) 12 way, Double door

2

-

1151

... More
….do….(2.3.4) 16 way, Double door

2

-

1364

... More
(2.10) Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (2.10.1) Single pole

40

-

173

... More
…do….(2.10.3) Double pole

6

-

463

... More
(2.16) Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts “C” curve DP MCB complete with connections, testing and commissioning etc. as required.

4

-

627

... More
(2.23) Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required (2.23.3) For 10 way, Double door SPN MCBDB

2

-

424

... More
…..do….(2.23.4) For 14 way, Double door SPN MCBDB

2

-

488

... More
(2.25) Supplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.

2

-

433

... More
(5.2) Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.

2

-

3672

... More
(5.15) Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

40

-

129

... More
(5.16) Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

1

-

37

... More
Providing & fixing of HPL make following items:- (3.1) 2 pole change over switch, 63A

2

-

3050

... More
…..do…... (3.3) 2 pole Main switch, 63A

2

-

3450

... More
Providing & fixing of Legrand / L & T /Hager/C&S make MCBs as follows:- (12.6.3) Single Pole, 40A

2

-

535

... More
……do…….(12.6.4) Single Pole, 63A

2

-

535

... More
……do…….(12.6.8) Double pole, 40A

2

-

1175

... More
……do…….(12.6.9) Double pole, 63A

2

-

1175

... More
Providing & fixing of Legrand/ L & T ORIS make Modular items/accessories as follows:- [Note:- GI/PVC modular boxes & accessories as required are to be provided & fixed by agency at no extra cost] (15.1) Bell ding dong, 230V, 2 module

2

-

295

... More
Providing & fixing of L & T make Single phase kWh meter with LED display (Base mounting), 1phase LED meter as follows:- (16.5.1) 5-30A with optical port, Cat No-WM101BC5DDH

2

-

1700

... More
(17) Providing & installation of Wipro/Crompton/Philips make LED luminaries as follows:- [Note:- The job includes providing & fixing of fixing accessories as required but excluding the GI/MS conduit pipes] (17.1.7) Wipro make Garnet 20W LED Batten / Philips make Astra line 20W LED Batten

46

-

450

... More
…do...(17.3) Skyline LED street light, Cat No. LR02-671-XXX-57-XXX, 60W

1

-

7850

... More
Usha- Striker/Crompton- Aura make & model 240 V AC Ceiling fans without regulator as follows:- (21.1) 48” sweep size with down rod up to 2 feet long.

12

-

2550

... More
…do….(21.3) 56” sweep size with down rod up to 2 feet long.

10

-

2650

... More
Providing & fixing of Usha/Crompton make 240V AC, Heavy duty industrial exhaust fan complete with bracket louvers & shutter with following:- (21.7) 12” impeller dia, 1400 rpm

1

-

3600

... More
Providing & fixing of Usha/Crompton make 240V AC, Crisp air fan complete with bracket louvers & shutter as follows:- (21.15 250mm size, 900 rpm

1

-

1600

... More
(33) Providing & fixing of GI bracket suitable for fixing street light, gate light etc.

1

-

450

... More
Supply & Installation including laying & dressing of the following LT power cables (1.1 KV grade, AYFY cables) on ready cable trenches/in air/concrete wall. [Note:-Supply of installation/Laying accessories & consumable required for Installation/Laying work shall be in the contractor’s scope. Before fixing the materials contractor shall have to get it approved from UWD's concern Engineer. Any discrepancies come to the notice of UWD regarding wrong materials supplied/ installation/ fixing/ laying for which contractor shall be responsible to correct it/them without any extra cost. Standard Aluminum conductor, XLPE/PVC insulated, colour coded, cores laid up, wrapped PVC/thermoplastic tape inner sheathed, single layer of galvanized flat steal strip/round steel wire armored and overall PVC outer sheathed power cable conforming to IS-1554(part-1)/1988 with latest amendments of the following sizes & make:- The make of the cable shall be of National/KEI/ Universal/Gloster/Polycab/ Nicco/Finolex make. Supply & Installation including laying & dressing of LT power cables of following sizes on ready cable trenches/in air/concrete wall:- (50.7) 3 ½ core ×70 sqmm

1

-

425

... More
(50.8) 3 ½ core ×50 sqmm

1

-

350

... More
(50.9) 3 ½ core ×35 sqmm

1

-

290

... More
(50.14) 2 core x 10 sq. mm

1

-

135

... More
(29.3)Excavation of earth cable trench minimum 900mm deep and 450mm wide and providing & underground laying/dressing of the following LT power cables (1.1 KV grade AYFY cabls). The LT power cable shall be stranded aluminium conductor, XLPE/PVC insulated, color coded, cores laid up, wrapped PVC/ thermoplastic tape inner sheathed, single layer of galvanized flat steel strip/round steel wire armoured and overall XLPE/ PVC outer sheathed power cable confirming to IS-1554(part-I)/1988 with latest amendments. Contractor shall submit the work test certificate of LT Power cable to UWD prior to supplying the materials at work site at no extra cost and also provide 1 Mtr. length of LT power cable as a test sample to UWD from each cable drum before start the work & contactor shall only start the work after getting the satisfactory test report of respective test sample of LT power cable. The work shall include filling of trench with dry river sand at bottom & top of the cable with 75mm thick layer, covering with ‘A’ class burnt red bricks at sides and on top (approximate 18 bricks per meter) for protection of cables back filling the cable trench after laying of cables with good soil and ramming. Supply of LT power cables, sand, bricks and cable tag are in the contractor’s scope. Wherever the cable trench crosses the road, the contractor shall make good the damages in the road during excavation work including back filling the trench with excavated earth and laying of above bricks of at least 2 layers on the road at no extra cost.The contractor shall also provide cable jack and shaft/turn table at site to facilitated cable laying at no extra cost. Contractor shall provide 2 mm thick, 25mm wide and 100mm long aluminium cable tag at the regular interval of 25 meter through out the length of underground laid cable, UWD shall provide cable identification number to the contractor and same shall be suitably punched on the above cable tag and fix it on laid cable with Al. wire/nylon rope of suitable size at no extra cost. All the corners of Al. cable tag shall be suitably filed in such a manner so as to avoid any sharp edges at no extra cost. Any damage done by contractor during the execution of work shall be made good by the contractor at no-extra cost. Before fixing/laying the materials contractor shall have to get it approved from UWD's concern Engineer/In-charge before fixing/installation/laying the materials.The make of the cable shall be of National/KEI/ Universal/Gloster/I Polycab / Nicco /Finolex make (51.7) 3 ½ core × 70 sqmm

10

-

665

... More
(51.8) 3 ½ core ×50 sqmm

1

-

545

... More
(51.9) 3 ½ core ×35 sqmm

1

-

465

... More
(51.14) 2 core x 10 sq. mm

1

-

360

... More
End termination of 1.1KV grade SWA PVC sheathed stranded Al. /cu conductor cable of the following sizes including supply of compression type cable glands & crimping type cu/ Al. sockets/lugs & all other consumables & accessories required for the termination. (52.4) 3 1/2 C x 70/50 sqmm. AYFY.

1

-

495

... More
….do…..(52.5) 3 1/2 C x 35/25 sqmm. AYFY.

1

-

435

... More
….do…..(52.6) 4 C x 16/10 sqmm. AYFY.

5

-

350

... More
….do…..(52.7) 4 C x 16/10 sqmm. AYFY.

5

-

305

... More
Supply & laying/fixing/grouting/hanging of GI pipe of following sizes:- [Note :- The GI pipe shall be of Tata/QST/ Jindal make, medium class & all fixing accessories like socket, union, reducer etc. are to be provided by the contractor at no extra cost] ((52(A).6)) 50 mm

12

-

560

... More
…..do…..((52(A).7)) 65 mm

1

-

600

... More
Providing & installation of legrand/ORIS make modular items on existing modular boxes as follows:- (63.13) Safety AC Power Unit, 25A

2

-

875



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.