Military Engineer Services Tender

BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Tripura government has posted on its website in a very hassle-free manner. BidAssist is designed in such a manner so as to provide information on all government tenders at one place without any inconvenience.

Military Engineer Services - MES Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date23 Nov 2024
Closing Date9 Dec 2024
Tender Amount₹ 19,50,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Removing excavated material to a distance n.exc 50M and deposited/ spreaded where directed at a level n. exc 1.5 M above the starting point complete all as specified and as directed .

23.21

-

-

... More
Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cable including spreading and punning down to 18 cm thickness complete all as specified and as directed.(Compacted thickness shall be measured)

19.44

-

-

... More
Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1, with peak, size 300mm x 180mm x 40mm in trenches on cable as cable protection across the length of the cable (width wise)complete all as specified and as directed.

1865

-

-

... More
Material and labour for PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.

1

-

-

... More
Materials and labour for providing cement concrete Type B1 1:2:4 ( 20 mm graded aggregate) as in coping of poles including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and as directed.

1

-

-

... More
Dismantling old unservicable steel tubular poles/struts, any size including breaking up PCC foundation and removal of rubbish complete all as specified and as directed.

3

-

-

... More
Supply and fixing steel tubular swaged pole, type 410 SP 55 (Overall length 11.00 meter) conforming to IS-2713 (Part 1 to 3) 1980 complete with cast iron base plate, finial taper plug, bolts, nuts and washers, screws. Pole shall be painted with two coat of black bituminous throughout internally and externally upto planting depth and the remaining external portion shall be painted with two coats of aluminum paints over a coat of red oxide primer including painting from bottom to 1.2m height alternative with 30cm red and white strip and writing pole no with black paint on yellow background complete all as specified and as directed. Note: (a) Earth work and PCC shall be measured and paid separately under relavent items of schedule 'A'/BoQ. (b) Design / drawing of HT pole and dimension is to be obtained from OEM/auth dealer/supplier and same is to be got approved from AGE(I) before placing order to the manufacturer.

3

-

-

... More
Material and labour for preparation of old painted surface of 11mtr long steel tubular electric pole by using emery paper, painting exposed surface with one coat of silver aluminium paint including painting from bottom to 1.2m height alternative with 30cm red and white strip and writing pole no with black paint on yellow background completed all as specified and as directed.

16

-

-

... More
Taking out existing old damaged / unserviceable HT UG cable of any size from trench /duct /pipe including jointing kit complete all as specified and as directed. Note:- Earth work shall be measured and paid separately.

240

-

-

... More
Supplying, Laying connecting & testing XLPE insulated, PVC sheathed, armoured HT electric power UG cable (heavy duty with stranded aluminum conductor) of size 95 Sqmm, 3 core, 11000 Volts(Earthed) grade, conforming to IS-7098 (Part-II) laid through duct/ pipe / in trench etc. with cable glands & suitable size of aluminium lugs complete all as specified and as directed. Note : Earth work, precast cable cover protection and sand cushioning and GI Pipe Shall be measured and paid separately under relavent item of schedule 'A'/BoQ.

240

-

-

... More
Material and labour as in replacement for HT 11 KV (Earthed) grade heat shrinkable end termination jointing kit indoor type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and as directed.

1

-

-

... More
Material and labour for HT 11 KV (Earthed) grade heat shrinkable end termination jointing kit outdoor type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and as directed.

5

-

-

... More
Material and labour for HT 11 KV (Earthed) grade heat shrinkable jointing kit straight through complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and as directed.

4

-

-

... More
Supply and fixing as in replacement Aluminium lugs of size 95 sqmm complete all as specified and as directed.

60

-

-

... More
Labour only for prunning of tree branches near electric overhead lines to make clear span of 3mtr on either side, all around the Over Head line with all tools, plants etc complete all as specifed and as dricted Note :Any breakdown of line during prunning shall be made good without any extra cost .

720

-

-

... More
Dismantling of old unserviceable air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism of any size or any type complete all as specified and directed.

5

-

-

... More
Dismantling old unserviceable D.O. fuse assembly complete including insulators complete all as specified and directed.

5

-

-

... More
Dismantling old unserviceable lightening arrestor 11/33KV complete all as specified and directed.

2

-

-

... More
Dismantling of old unservicable insulators any size complete all as specified and as directed.

12

-

-

... More
Supply and fixing Pin type insulator, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade confirming to IS 1445-1977 & IS 731-1971 complete all as specified and as directed. .

3

-

-

... More
Supply and fixing Disc type insulator, porcelain, vitreous 145 mm high and 255mm dia ball and socket type, white, brown or green, Single disc assembly for tension with tension clamps for conductors, working pressure 11000 volts grade conforming to IS-731 & IS-3188 complete all as specified and as directed.

3

-

-

... More
Material and labour for Loop type insulator, vitreous porcelain, white, brown or green, large size with overall dimension 90x140mm clearance of hole 25.5mm complete all as specified and as directed.

6

-

-

... More
Supply and fixing triple pole mechanically operated air break isolator (GOD), vertical mounting, rotating type, mounted on insulator and steel frame with operating mechanism worked from ground level complete in all respect such as gun metal moving contacts and spring loaded gun metal fixed jaws, knife copper jumper strip etc, suitable for 11000 Volts grade, 50 Hz, with 9 insulator of rating upto 400 Amps including taking down existing GOD complete all as specified and as directed.

5

-

-

... More
Material and labour for expulsion type drop out fuse single pole mounted on insulator for 11000 volt and current rating above 50 Amps & upto 100 Amps including taking down existing unservicable DO fuse complete all as specified and directed.

5

-

-

... More
Disconnecting all electrical connection from Air Break Switch (GOD) vertical/Horizontal Type / DO fuse of 11KV capacity, cleaning all parts and greasing all moving parts for smooth functioning and replacement of fix contacts, flexible copper rod, GI nut, bolt etc complete all as specified and as directed.

5

-

-

... More
Material and labour for HT outdoor expulsion type lightening arrestor with mountings accessories complete fixed on cross arms of two pole structure/GI flat strip and connect with same size of ACSR conductor with all fittings connected to earth strip with nut, bolt, washer transmission class having discharge capacity of 65 kilo Amps and suitable for working pressure 11 KV complete all as specified and directed.

2

-

-

... More
Material and labour for conducting oil filteration by stream line/Vaccum type filter machine to improve required BDV incl routine testing after filteration for any capacity of transformers complete all as specified and directed.

970

-

-

... More
Material & labour for new transformer oil of BDV not less than 60KV for topping up of reduced level of 33KV/11KV transformers and CTs complete including removing of old unserviceable transformer oil all as specified and directed.

970

-

-

... More
Material and labour for painting the outer surface of the transformer with two coat of synthetic enamelled paint after preparing the surface dust and oil free and cleaning the bushes,name plate etc paint free after painting including writting the MES/SM No with white enamelled paint for capacity of transformer 100KVA to 600KVA (Indoor/outdoor type) complete all as specified and directed.

8

-

-

... More
Supply and laying GI tubing 80mm bore light grade with fittings laid in trenches for protection of HT/LT underground cables including taking down old unserviceable pipes complete all as specified and as directed. .

6

-

-

... More
Supply and laying GI tubing 100mm bore light grade with fittings laid in trenches for protection of HT/LT underground cables including taking down old unserviceable pipes complete all as specified and as directed.

6

-

-

... More
Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connected with GI strip of size 25x4mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking down old unserviciable earthing set all as specified and as directed. Notes:- (i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department.

4

-

-

... More
Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 40 mm, Medium Grade and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking down old unserviciable earthing set all as specified and as directed. Notes:- (i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department.

4

-

-

... More
Taking down carefully the existing transformer upto 500 KVA capacity and draining out transformer oil into clean barrel for reuse and transporting it to civil workshop for carrying out the maintenance works, return back on existing site and refixing the same and testing complete all as specified and as directed by Engineer-in-Charge :- Note:-(i)To and fro transportation of transformer are deemed to be included in quoted rate. (ii) Charges for Loading/ unloading of transformer at substation and workshop are deemed to be included in quoted rate. (iii) Charges for commissioning and testing at site are deemed to be included in quoted rate. (iv) Cost of Making temporary arrangement with existing standby Transformer for power supply is deemed to be included in quoted rate.

5

-

-

... More
Material and labour for Major repairing of the transformer of capacity upto 500 KVA including lifting, dismantling of core and coils, cleaning, washing and rectification of tank, cooling duct, reassembling, including gas welding of bottom drain pipe etc as required and testing complete all as specified and as directed by Engineer-in-Charge. Note: The spare parts reqd for repair/replacement shall be measured and paid as supply only under relavant items and fixing of the same is deemed to be inclusive in this Item.

5

-

-

... More
Supply only of brass terminal rod with nuts,bolts,washers & bushings suitable for HT side of the transformer of any make and capacity from 100 to 250KVA complete all as specified and directed.

12

-

-

... More
Supply only of brass terminal rod with nuts,bolts,washers & bushings suitable for LT side of the transformer of any make and capacity from 100 to 250KVA complete all as specified and directed.

12

-

-

... More
Supply only of bush type insulator white/brown/green working pressure 11000Volts HT side complete all ads specified and directed.

6

-

-

... More
Supply only of bush type insulator white/brown/green working pressure 433Volts LT side complete all as specified and directed.

6

-

-

... More
Supply only silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 100KVA to 500KVA transformer complete all as specified and directed.

6

-

-

... More
Material and labour for rewinding of high voltage coil with super enameled copper winding wire of existing gauge, varnishing, impregnated paper insulating and drying the complete coils complete all as specified and directed. Note:-Cost of keeping the winding with care in electric oven for 72 Hrs to improve the insulation is deemed to be included in the quoted rate.

180

-

-

... More
Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised wire of 4mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking down old unserviciable earthing set all as specified and as directed. Notes:- (i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.