South Central Railway Tender
For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.
Costs
EMD
₹ 1,03,200Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
B-E29-TRD-TNDR-12-24-25-VIJAYAWADA DIVISION-ELECTRICAL/SOUTH CENTRAL RLYTender No
B-E29-TRD-TNDR-12-24-25Tender Authority
South Central Railway ViewPurchaser Address
-Website
http://ireps.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
4 (a) (iii)Supply without insulator and erection of single bracket assembly suitable for Tramway type OHE.(Regulated) 7
-
-
148960
8(a) (vi)Supply and erection of regulating equipment (3 pulley type) with counter weight assembly for Tramway type OHE. 9
-
-
86499
8 (b) (vi)Supply without insulator and erection of materials for termination of Tramway type Over Head Equipment (Regulated)
-
-
7840
12(c )Supply without insulator and erection of 25 KV Section Insulator assembly suitable for Tramway type OHE. 14
-
-
76160
13(c)Supply without insulators and erection of 25KV Double pole isolator. 15
-
-
93884
13(d)Extra for Supply and erection of an Earth Contact assembly in an isolator. 16
-
-
16828
13 (e )Extra on item 13(a), (b) or (c ) for an interlocking device 17
-
-
6062
15(a)Supply and erection of all types of copper jumpers. 18
-
-
30065
16(a )Supply and erection of structure bonds. 19
-
-
21000
16(aa)Drilling of holes on rails 20
-
-
4200
16(b )Supply and erection of longitudinal bonds. 21
-
-
7455
16(c )Supply and erection of a transverse and special bond. 22
-
-
8190
31(a) Transfer of equipment from one mast or support to other. 23
-
-
29610
31(f)Splicing and extension of Over Head conductors. 24
-
-
3864
31 (h)Slewing of Equipment. 25
-
-
15715
31 (k) (i)Dismantlement of OHE masts/structure by cutting. 26
-
-
14700
31 (l) (i)Retrieval of traction masts, main masts, TTC uprights etc. 27
-
-
17500
31(n)Dismantlement of guy rod. 28
-
-
791
31 (t)(ii)Dismantling of a regulating equipment (Three pulley type) with counter weight assembly for Tramway OHE.
-
-
1249.5
32/3 (a)Erection of traction masts and main masts of switching stations & LT supply transformer station under Power Block.
-
-
3199
32/3 (b)Erection of fabricated steel work such as TTC, Portals, SPS etc under Power Block. 32
-
-
178101
32/4(a) (iii)Erection of single bracket assembly suitable for Tramway type OHE under power block.
-
-
11088
32/ 8 (a)(vi)Erection of regulating equipment (3 pulley type) with counter weight assembly for Tramway type OHE under power block.
-
-
4998
32/8 (b)(vi)Erection of materials for terminations of Tramway type OHE under power block.
-
-
1372
32/ 12 (c )Erection of 25 KV Section Insulator assembly suitable for Tramway OHE under power block. 39
-
-
4179
32/ 13(d)Extra for supply and erection of an Earth contact assembly in an isolator under power block. 41
-
-
504
32/ 15(a)Erection of all types of copper jumpers under power block. 42
-
-
2030
32/ 31(a)Transfer of equipment from one mast or support to other under power block. 43
-
-
29610
32/ 31(f)Splicing and extension of Over Head conductors under power block. 44
-
-
3864
32/ 31(h)Slewing of Equipment under Power Block. 45
-
-
15715
32/31 (k) (i)Dismantlement of OHE masts/structure by cutting under power block. 46
-
-
14700
32/ 31(l) (i)Retrieval of traction masts, main masts, TTC uprights etc. under power block 48
-
-
17500
32/31 (t)(ii)Dismantling of a regulating equipment (Three pulley type) with counter weight assembly for Tramway OHE under power block. 50
-
-
1249.5
33/3 (a)Extra on erection rates for steel work done manually under item No. 3 (a) 51
-
-
1596
3(a) Supply of Traction masts and main masts of switching stations, LT supply transformer station and booster transformer station as per latest RDSO drawings and IS Specifications.
-
-
201204.5
3(b)Supply of fabricated steel work other than masts such as TTC's, portal sets (with all components) etc as per RDSO drawings and IS specifications.
-
-
1846278
3(c) Supply of Fabricated steel work other than mast, TTCs, portals, such as SPS, special fabricated steel etc.
-
-
313619.25
56 Supply of Porcelain stay insulator(1050 CD) 57
-
-
76825
8 (bx) (ii) Supply of insulators for item no 8(b)(i)/(ii)/(iii)/ (v) // (vi)/ (vii)/ (viii)/(ix) for polluted zone. 59
-
-
7849.4
11(ax) (ii) Supply of insulators for item 11(a) (i), (ii) for polluted zone. 60
-
-
23548.2
11(bx) Supply of 25 KV post insulator for item 11(b). 61
-
-
25513.8
12(cx) Supply of bar Insulator for Item No. 12(c ). 62
-
-
9812.4
63 PG Clamps (1041-2) 64
-
-
79948
64 Catenary wire ending cone 65
-
-
92114
66 Supply of 5 mm dia droppers with dropper clips as per latest RDSO specification. 67
-
-
22288
67 Re-adjustment of OHE spans including erection of droppers. 68
-
-
16716
68 Re-adjustment of OHE spans including erection of droppers under power block 69
-
-
16716
69 Supply and erection of splice. 70
-
-
51117.53
70 Erection of splice under power block. 71
-
-
835.8
71 Dismantling of existing droppers 72
-
-
3343.2