South Central Railway Tender

... More
For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.

South Central Railway - SCR Tender

Works
Ireps
Opening Date7 Feb 2025
Closing Date17 Mar 2025
Tender Amount₹ 22,18,19,282.53 
Notes
Download

Costs

Summary

Outdoor Signaling Works At Kzj Yard In Connection With The 3rd Line Works In Kzj- bpq Section

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of CLS Post 140mm dia to specification IRS:S 6-81 Rev.3 or latest (Inspection by Rites) (a) 4.5m long

20

4710

94200

... More
Supply of CLS Ladder set complete with staging/platform, supports, cast iron ladder base/Shoe.(Inspection by Rites) (a) Ladder for 4.5m post as per ORG.. No. SA 23153, S 2033 or latest

20

6432

128640

... More
Supply of Offset Bracket to suit 140mm dia CLS post with two numbers of U bolts and nuts complete. (Inspection: Rites)

25

4938

123450

... More
Supply of Calling On Signal Unit complete with U Bolts as per RDSO DRG. No. SA.24351 (Adv.) or latest. (Inspection by Rites)

35

4740

165900

... More
Supply of Ground type position light shunt signal complete with base, pipe, arrow mark and hoods as per RDSO ORG. No. SA 23840 or latest.(Inspection by Rites)

45

6083

273735

... More
Supply of Post type position light shunt signal with hoods, arrow mark and offset bracket to suit 90mm sockets (CLS) with two numbers of 'U' bolts and nuts complete to fix shunt signal below main stop signal as per ROSO DRG. No. SA 23840 or latest. (Inspection by Rites)

30

3502

105060

... More
Supply of GKP type Location Boxes (Inspection by Rites) (a) Full size as per drg. No. S&T/MFT/T.2378

240

16216

3891840

... More
Supply of Universal Locks with one steel key for every ten locks or part there of (For example, if locks ordered is 10,1 key is to be supplied and if locks ordered is 20, 2 keys to be supplied. However, 2 keys to be supplied if locks ordered is between 11 and 19). (Inspection by consignee)

500

195

97500

... More
Supply of relay fixing frame for full location box. The frame shall be of approximate size 940mmx150mm and made with powder coated MS angle of 25mmx25mmx 3mm. The frame shall have suitable holes to fix in full location box. (Inspection by consignee) 13

70

853

59710

... More
Supply of Insulations for Ground connections 14

-

-

307595

... More
Supply of Ground connections for point machines (Inspection by RITES)

-

-

2161050

... More
Supply of Track feed battery charger to work on 11OV AC for charging 1 or 2 or 3 or 4 lead acid cell of 8OAH (10 Amps) used in track circuit as per RDSO Specn. No. IRS.S.89/2013 Ver 1.0 latest. (Inspection by RDSO)

85

8294

704990

... More
Supply of B type chokes to as per specification IRS: S65- 83 Amd.l or latest. (Inspection by RDSO)

200

2313

462600

... More
Supply of Track lead junction boxes fibre glass as per DRG.No.CWM-00597 of F.R.P 17 material to and specification IRS:S 23 along with fixtures i.e., one MS angle 50mmx50mmx5mm, 0.9m long, two numbers of G.I pipes of 25 mm dia, 500 mm long along with nuts and bolts and 500 mm long (grommet bushes, 60 mm ARA terminals-2 No's).(Inspection by Rites)

550

1546

850300

... More
Supply of Stationary low maintenance secondary lead acid cells as per RDSO specification IRS: S88-2004 or latest. This includes supply of inter cell connectors, bolts, nuts, acid level indicating floats and vent plugs. (Inspection by RDSO) (a) 2V, 80AH

300

3315

994500

... More
Supply of AC immune, plug-in type, Style 'QTA2', 2F/1B DC Neutral track relay for 19 railway signalling track circuits with coil resistance 9 ohm, complete with plug board, retaining clip and connectors as per specifications: BRS 939A & 966 or Latest, IRS:S 23-88 Amd. 1 or latest, IRS: S 34-68 Amd. 6 or latest, IRS: S 67-85 Amd. 3 or latest (as applicable) with interlocking code FGHKX. (Inspection by RDSO)

250

4806

1201500

... More
Supply of 24 V DC plug-in type miniature tractive armature, AC immune relay complete 20 with plug board, retaining clip/ATC Clip and connectors as per IRS: S 23-88 Amd. 1 or latest, IRS: S 34- 68 Amd. 6 or latest, IRS: S 60-78 Amd. 1 or latest, IRS: S 67-85 Amd. 3 or latest (as applicable).(a) QBCA1- 2HF/4B, Interlocking code: BCEJK as per specifications BRS 943 or Latest(Inspection by RDSO) 21

80

8307

664560

... More
Supply of PVC insulated Wire Coils

-

-

440600

... More
Supply of non-deteriorating type of fuse holders and fuse links 240V AC/DC as per specification IRS: S 78-2006 or latest, IS 13703 (Part 2):1993 knife edge type fuse of EI fuse link type (up to 20A) (a) Fuse holder 20A capacity (Inspection by RDSO)

1000

220

220000

... More
Supply of Terminal Block (a)Terminal block: 1 way Poly butylene Terephthalate (PBT) of 23 size 60mm (link centre to centre) as per RDSO DRG. No. SA23745/Alt.5 or latest, SA23746/Alt.5 or latest, S23747/Alt.5 and specifications IRS: S 75-2006 Rev. 2.0 (Tentative) or latest, IRS: S 23-88 Amd. 1 or latest. (Inspection by RDSO)

2000

97

194000

... More
Supply of mini WSB markers for modular terminals WAGO Model No. or similar - 100 Nos. (Inspection by Consignee)

300

64

19200

... More
Supply of Hylam sheet, resin bonded, grade P3 as per IS specification IS 2036 of 1974 or latest of following size: (Inspection by Consignee)

-

-

74652

... More
Supply of 50mm X 6mm GI tape for interconnecting earth electrodes. (Inspection by Consignee)

700

546

382200

... More
Supply of GI termination box (10 SWG) for point machine of size 45 cmx23 cmxl2 cm 28 with double coat of enamel paint (outside: Black & inside: white) along with 2no's of MS angle of size 50x50x6mm of length 1000mm each, 2 numbers of 40mm GI pipe of length 450 mm & 150 mm with nuts/washers and teak wood plank of size 40 mmx25 mm for fixing of terminals. (Inspection by Consignee)

165

2902

478830

... More
Supply of portable Cable Fault Locator (Metallic Time Domain Reflectometer) suitable in 29 RE / Non-RE Railway territory with all accessories for locating faults such as loop and break in various twisted pair cables such as underground telecom quad cables, signalling cables, telephone jelly filled cables, LAN etc. Instrument to be supplied with protective nylon carrying bag and Operator's manual. (Inspection by Consignee)

1

317822

317822

... More
Supply of Track Feed Regulating Resistance disk type 00 to 300 as per ORG. No. SA 20161 66/M or latest. To be procured from RDSO approved firms.(Inspection by RDSO)

260

358

93080

... More
Supply of Galvanised Wire rope 6/19 steel, 6 mm dia with fibre core as per specification IS 3459/2004 or latest (Inspection by Consignee)

8000

80

640000

... More
Supply of Electronic earth tester Model No. 4680B Meko make or higher version or 32 similar. The earth tester shall be non-contact type without requirement of auxiliary electrodes and shall have 4 digit 9999 LCD display with ground resistance range from 0.25 to 1500. (Inspection by Consignee)

1

83799

83799

... More
Supply of Housing rack for 1-9 Multi lamp Route Indicator of 2mm MS thick sheet with mounting socket on signal post (LED single digit). (Inspection by RITES) 34

27

20309

548343

... More
Supply of Metallic (MS) colour light Signal Unit.

-

-

694239

... More
Supply of vitreous enamel coated board of 230mm dia. (A, P, G, C, IB markers) made of 2mm thick sheet as per following colour scheme: 1 )'G' marker - Yellow back ground, black letters 2) Other boards - White background, black letters (Inspection by Consignee)

50

267

13350

... More
Supply of 280mmx102mmx2mm thickness vitreous enamel coating arrow markers board fabricated with MS clamp of size 40mmx6mm along with suitable bolts and nuts.(Inspection by Consignee)

150

370

55500

... More
Supply of ECR 4F/4B for 110V AC lit LED signals, complete with plug board, retaining 37 clip and connectors as per RDSO specification No. STS/E/Relays/AC Lit LED Signal/09-2002 Amd. 1 or latest, BRS 941A, IRS: S 23-88 Amd. 1 or latest, IRS: S34-68 Amd. 6 or latest, IRS: S 67-85 Amd. 3 or latest (as applicable). The interlocking code for this unit shall be ABDHK (with ATC clips).(Inspection by RDSO)

350

5841

2044350

... More
Supply of powder coated Cable termination rack of size 880mm x 2075mm made using 50mm x 50mm x 6mm (6mm thickness) MS angles. The cable termination rack shall be supplied with stainless steel nuts and bolts for fixing the rack, tripod bases and reel insulators (for K rack, P rack and power rack), cable ladder of 400mm width and 2075mm length with two angles of size 40mm x 40mm x 5mm (5mm thickness) and supporting flats of size 25mm x 25mm. Suitable holes shall be drilled to fit hylam sheet as per standard practice (Inspection by Consignee)

-

-

38

... More
Supply of Fuse Auto Changeover system of various types of fuses with audio visual indication as per specification RDSO/SPN/209/2012 Ver. 2.0 or latest. One module shall be able to cater for 32 numbers of fuses (Inspection by RDSO)

35

46656

1632960

... More
Supply of Battery Charger of Various capacity (a)230V AC / 110V DC, 30A single phase, signalling! telecom. Installation as per specification IRS: S 86-2000 Amd. 4 or latest.(Inspection by RDSO) 41

7

110464

773248

... More
Supply of Transformer - Rectifier as per specification IRS: S 91-2014 Ver. 1.0 or latest

-

-

454300

... More
Supply of Earth Leakage Detector (ELD) with configuration specified by Engineer In 42 charge and as per specification RDSO/SPN/256/2002 or latest with insulated tester, test probes, Mounting stand and Fuse board to isolate from distribution board as per requirement of channels. (c) Twelve channel Earth Leakage Detector. (Inspection by RDSO)

6

190261

1141566

... More
Supply of Control and Distribution panel for Colour Light Signalling supply in 25kV AC traction system suitable to work on 3 supplies 25kVA AT, 240V AC single phase, 50Hz, 150A capacity 43 specification TI/SPC/PSI/CLS/0020 with A & C Slip 1 to 4 or latest, CORE approved DRG. No. ASCOS/25KVAICORE/2007/01 Rev.01 or latest. The panel shall have automatic changeover facility and shall be supplied with one additional rotary switch and meter. The panel shall be of Suntron or similar make.(Inspection by RITES)

6

227480

1364880

... More
Supply of Data Logger of following capacity for remote monitoring of signalling 44 parameters and power supply arrangements with network as per specification IRS: S 99- 2006 Amd. 3 or latest with 64 input digital card as a spare and fuse monitoring PCBs for monitoring at least fifty 2A fuses with inbuilt modem cards for networking.

-

-

3110649

... More
Supply of communication and other accessories for Datalogger (Inspection by Consignee)

-

-

2006718

... More
Supply of 80 column Dot Matrix Printer Model No. Epson LQ300/LX300 or similar with serial port. (inspection by consignee) 47

7

13177

92239

... More
Supply of Various Telephones and Telephone Power Supply unit 48

-

-

165027

... More
Supply of Various Telecom Cable

-

-

378046

... More
Supply of following type of Terminal block of Wago Make or Similar (with lever type disconnection & reconnection facility) duly fitted in C.T. box of approved quality, suitable for termination of cable from 0.4mm to 0.9mm conductor.(b) 24 pair (inspection by consignee)

20

3240

64800

... More
Supply of Maintenance Free Batteries of following capacity of AMARAJA/EXIDE/Panasonic or equivalent brand. (a)12V/65AH (Inspection by RDSO) 51

10

7674

76740

... More
Supply of OFC Related items 52

-

-

1227634

... More
Supply of IP Based CCTV Camera 53

-

-

87198

... More
Supply of Miscellaneous Telecom Items

-

-

56470

... More
Real time Earth measuring Device of split core structure, High Accuracy, Resistance 54 Range 0.010-1000, Detector Light and Sound Alarm, IP-54 protection, RS-485 Communication, with extended 4 digit LCD of Koble or Similar make (Model No. KOBLE 2800KB VER 3.0 or similar): a) Main detector Unit -01 No b) LCD Enclosure fitted with Aviation Plugs-0l No. c) Rs-485 Connector with 0.5 Mtr Cable-0l No. d) RMCU with PFC -01 No. e) All other connecting cables with accessories 55

6

65725

394350

... More
Supply of piezo buzzers working on 24 V DC reputed make.(Inspection by Consignee) 56

10

78

780

... More
Supply of PVC Pipe 110mm dia, 6m length including joints.(Inspection by Consignee)

500

1163

581500

... More
Supply of PVC Conduit pipe 3m length, 25mm dia with required number of bends. (inspection by consignee) 58

500

51

25500

... More
Supply of following items for station 59

-

-

1614560

... More
Supply of Various Tools for S&T installation

-

-

176215

... More
Supply of HDPE pipe of various diameter with material grade PE 100 as per specification IS Specification 4984: 1995 up to latest amendment.(a) HDPE pipe of 110mm Dia. (Inspection by RITES)

8000

358

2864000

... More
Supply of thick Kodak photo paper with lamination and different lettering in languages and required size as per the instructions of site in-charge.(Inspection by Consignee)

50

5679

283950

... More
Supply of commercial grade operator VDU of size 55' Full HD, with backlit LED, with HDMI/DVI port, Inbuilt Speaker, required HDMI/DVI cables for connectivity and other miscellaneous item required for installation. (Inspection by Consignee)

5

226320

1131600

... More
Supply of fan less embedded industrial grade computers (Similar to Moxa V2406A or 63 better ) with all accessories such as key board, mouse, antivirus etc. of industrial grade as per approved Specification as recommended by RDSO (TAN No. STS/TAN/3007 Version 1.0 or latest) (Inspection by Consignee)

5

182900

914500

... More
Supply of Distilled water for topping of secondary cells as per specification IS 1106 or latest. (Inspection by Consignee)

1500

10

15000

... More
Location survey for cable route and preparation of tentative cable route plan as per the instructions of Engineer in- Charge.

-

-

1

... More
Digging of cable trench to a depth of not less than 30 cm in rocky terrain/difficult terrain Concreting the trench with 150mm thick concrete with 1 cement: 2 sand: 4 graded stone aggregate 20mm nominal size. All the material is to be arranged by contractor.

3000

188

564000

... More
Trenching under Rails for crossing the track (Track Crossing) and refilling of trenches as per SCR Drg. No. 5768. The track crossing shall be done at right angles. The depth of cable trench 3 shall be 1.2 meter below the rail flange. The depth between top cable and the level of rail flange of the rail shall never be less than 1.0 meter. The ballast shall be stacked separately while making the trench and the earth soil shall be stacked separately. While re-filling the trench, the earth soil has to be filled first to the ground level and the ballast has to be properly put in the track. This work has to be done under supervision of supervisor of S&T and supervisor of P.Way.

5000

1139

5695000

... More
Excavation of trench, including marking of cable alignment, clearing of jungle, roots of 4 trees, bushes, trial pits if required, refilling with excavated soil, ramming and consolidation after laying of cables complete to the finished item of work in all type of Soil including soft rocky area as per RDSO Sketch No. SDO/CABLE LAYING/003, as directed by engineer in charge.

-

-

2825000

... More
Providing of channel ramps for drawing cables at bridge/culvert entries duly providing 6 GI bend/ flexible conduit 8 cm diameter and constructing channels from a depth of 0.8 meters to surface as per Drg no 15-D7 of IRSEM.(Concreting to be done at the ratio of 1:4:8 - Cement, sand and fine metal). All required material to be supplied by contractor.

50

734

36700

... More
Supply and fixing of galvanised MS-C' channel of size 100mmx 50mm x 1200 mm with 7 suitable clamps as per drawing No. S&TI RE/78/2/76 and fitting of GI pipe supplied by Railways and with suitable clamps on Girder Bridges without drilling holes in the girders. GI Pipes are to be drilled with 6 holes of 1/4" dia. per Meters around the pipe in zig zag manner before laying the 6 Meters pipe. (Inspection by Consignee)

1000

776

776000

... More
Track crossing/ Road Crossing by Horizontal Boring method at culverts/track/pucca road as per SCR Drg. No. 5770. This also includes insertion of HDPE pipe of 110 mm/G.l Pipe of 100 mm in the bore drilled (HDPE pipe/ GI pipe is to be supplied by Railway).

8000

2264

18112000

... More
Breaking of metal/ tar road and refilling after laying the cables as per drawing no. SDO/CABLE LAYING/010. The surface of the road shall be concreted to match with the old surface.

2500

211

527500

... More
Supply & Laying of G.I Pipes with medium and threaded collar & coupler, quality to specification IS.1239 (part-I) 1990 and galvanised to specification IS 4736-1986.(Inspection by RITES)

-

-

1752750

... More
Supply, placing and covering of RCC duct from Home to Home as per SCR Drg. No. 5778.(Inspection by RITES) 12

5000

2174

10870000

... More
Location box foundation and erection

-

-

4705290

... More
Supply and fixing of following Teak wood reapers/ Blocks after applying two coats of wood primer.

-

-

440315

... More
Cable termination including fixing terminals, fuses, LDs, Meggering of cables and recording the readings.

-

-

14

... More
Supply and fixing of teak wood reapers suitable for Full location Box with approx 50 mm width x 20mm thick and length of 940mm after applying two coats of wood primer. (Number = Per Reaper)

1250

183

228750

... More
Foundation & erection of Shunt signal which includes a) Excavation of pit and casting concrete foundation as per Drg. No. SG/CN/02/10 using metallic templates, for erection of ground type colour light Shunt signal. (Foundation bolts and nuts, cement, river sand, stone jelly of size 20/25mm and all other miscellaneous materials for the work shall be supplied by the contractor). b) Erection of 17 Ground type shunt signal complete including surface base, signal post, LED aspects, number plate, termination of tail cables, wiring of signal unit, provision of EWS locks and painting of one coat of red oxide and two coats of Aluminium /.enamel paint, (Supply of Ground type shunt signal complete including surface base, signal post, LED unit is to be supplied by Railways). [ EWS locks, enamelled number plates, bolts and nuts, lead wool, paints and all other miscellaneous materials shall be supplied by the contractor). @40<37@ Payment after completion of work mentioned at (a) and remaining 40 % after completion of work at (b))

45

6805

306225

... More
Manufacturing, Supply, painting and fixing of markers of G/P/C/A/AG/IB Markers as per IRSEM Drg.No.19-D10 on MS sheet of thickness 3mm. Miscellaneous material required for fixing Markers is to be supplied by contractor.

-

-

18

... More
Fixing of universal point machines and wiring on PSC/Wooden sleepers as per standard 19 drawing. Wiring as per circuitry includes fixing & wiring of point contactor unit frames and controlling relays, fixing and wiring of point termination box, fixing of crank handle ward plate of required configuration and Ground connections, P-clamp insulations, setting, stretcher bars etc., [All miscellaneous material required such as nuts, bolts, washers are to be arranged by contractor]

150

6460

969000

... More
Supply and Installation of High-voltage-resistant insulated Down Conductor for keeping the separation distance from conductive parts according to EN 62305-3 Equivalent separation distance 20 s =< 75 cm (in air) or s =< 150 cm (solid building material).Weather-resistant and UV stabilised Material of conductor: Cu , Material of insulation: PE Material of sheath: PE Diameter (phi)conductor: 50 mm standard: DIN IEC/TS 62561-8 (VDE V 0185-561-8) along with all accessories such as PVC Pipe, Insulation etc.(Inspection by RITES)

180

2750

495000

... More
Fixing of Track lead junction box on angles (50 x 50 x 6 mm size), drilling one hole on either side of the box of suitable size and fixing track lead junction box by the side of the track, drilling 21 4 holes of 7.2 mm dia. on Rail, connecting double track leads with bond pins, running track lead wire, termination of track lead wire on ARA terminals duly fixing the same inside the TUB Teak wood board bolted inside the track lead junction box. (Fixing angles, bolts, nuts and teak wood boards to be supplied by the contractor).

1400

505

707000

... More
Wiring of Track circuits feed end, relay end complete with TLDs, batteries, chargers, 22 Chokes, track relays, double lead wires, providing insulation etc,.Connected with track commissioning of track circuit including provision of bracket for TLD covers and painting. Anti-tilting arrangement has to be done for chargers & batteries. All miscellaneous material required for installation shall be supplied by contractor.

300

1509

452700

... More
Drilling of four no's of 7.2mm holes, per rail joint on web of the rail , providing bond wires with wire rope. (Bond pins single groves are to be supplied by contractor - Wire rope for bonding will be supplied by Railways). (Numbers = Per Rail Joint) 24

2500

134

335000

... More
Initial Charging of Secondary Cells with uninterrupted Power Supply: - (a) 2 volts 80 AH

1050

328

344400

... More
Fabrication, supply and erection of conventional Earth to Siqnallinq/Telecom equipments -Excavation of earth and No. 6652 providing earth pipe of size 50mm dia. 3.5mm thick 2.0 m. long G.I. pipe of heavy quality with masonry tub constructed around at earth locations as specified 25 by site Engineer. Alternate layers of 30kgs-charcoal and 30kgs-common salt to be filled in the pit while closing. The pipe perforation etc., to be carried out as per drawing No. SK 10/10. The earth pipe to be connected to the function with cable as supplied by Railways. The reading should be painted on the masonry tub. The masonry tub of 300 mm x 300 mm x 300mm (along with Kundi) should be covered with cement slab.(Inspection by Consignee)

250

6652

1663000

... More
Installation of single earth(maintenance free) including the following:- welding and fixing of copper tape (used as bus bar) welding of cadmium bronze cable to copper plate using material supplied vide item no. 1,2 of SPD of Sch-A. All the material supplied for mounting of copper tape, exothermic weld materials, tools and fixtures for welding copper tapes shall be arranged by contractor. a) Digging /Auguring/Boring of single earth pit of 100mm to 125 mm dia to the depth of approx. 2.8 meter. b) Insertion of 3.0 meter electrode and penetrating it at least 0.2 meter by pushing gently with sledge hammer where the natural soil is assumed. c) Filling of earth pit with earth enhancement compound (EEC) in slurry from and backfilling. d) Carrying out exothermic weld 26 connection on single earth electrode to a copper tape of 150X25X6mm. e) Carrying out exothermic weld connection on the copper tape of 150X25X6mm on earth electrode for connecting two 35 Sq mm cables for redundancy. f) The exothermic welding material for bonding the earth system shall be procured from RDSO approved firms, which includes graphite moulds, clamps, weld metal powders. g) Digging a trench to a depth of at least 0 .5 Mtr. and run the two 35 Sq mm earth conductor (procured against supply item) from earth pit to MEEB. h) Routing and termination of two 35 sq mm earth conductors in trench from earth pit to 300X25X6mm MEEB, which is to be fixed inside the equipment room with two insulation studs. i) 300X300X300 mm (inside dimension) concrete earth pit with a concrete lid, approx 50mm thick with pulling hooks, shall be provided to cover the pit. Back side of the cover will be painted in black and date of the testing and earth resistance value shall be written.

100

6338

633800

... More
Fabrication, Supply and fixing of CALLING ON instruction boards, STOP boards! BSLB/Shunting Limit Board/Auto section board or any other board with engineering grade reflective sticker of size 600X1 000 mm GI sheet, with MS angle of 75X75X6 mm with 6 meter length including paint, excavation of pit and concrete foundation etc. as per the instructions of sight in-charge. All necessary materials to be arranged by the contractor).(Inspection by consignee) 28

15

5314

79710

... More
Fixing of the following on Pre-erected Relay Racks

-

-

736410

... More
Releasing of the following equipments without causing damage, stacking neatly at a centralised place near the site of work as shown by the in charge, and handing over the same to the Stores depot as per the inventory made.

-

-

1833391

... More
Cable Duct behind Relay Room/Goomties of 1.8 m dia. and 1.2 meter depth consisting of brick work of 254 mm thickness of proportion 1:6 with sand filling after coiling of cables. The top of 31 sand filling covered with concreting of size 1.3 meter dia. and 200 mm depth of proportion 1:1.5:3. Outside of the duct should be plastered with cement mortar in a ration of 1: 6 to achieve smooth finishing. All materials including cement, chips of size 20 mm and second class bricks etc. to be supplied by the contractor. 32

6

9924

59544

... More
Provision and laying cement concrete (including transportation of all the material).

-

-

175245

... More
Supply, transporting and installation of Concrete (RCC) Route Indicators at intervals of 33 50 meters as per instructions of engineer in charge as per drawing no. SK 12/10.They should be of standard RCC with letters "SCR S&T cable" as per type of cable laid to drawing. In case of telecom quad cable joint locations it shall be painted with GREEN and ORANGE colour for normal indication of cable path. (Inspection by RITES) 34

1000

1204

1204000

... More
Tie Bar Fencing

-

-

2375000

... More
Foundation and erection of Colour light signal which includes a) Excavation of pit, casting concrete foundation as per SCR Drg. No. 5772 using metallic templates, for erection of Colour light Signals 4 aspects (foundation bolts, cement, river sand, stone jelly of size 20/20mm dia and all other miscellaneous materials required for the work shall be supplied by the contractor). b) Erection of surface base, signal post, mounting of Colour Light Signal up to 4 aspects complete on signal post! offset bracket, LED fixing, plumbing of the signal through sealing gap between Surface base and signal post, fixing of ladder with platform complete and concreting of ladder shoe, fixing of number 35 plates, marker board, termination tail cables, wiring of signal unit, provision of EWS locks, and painting of one coat of red oxide and two coats of aluminium/enamel paints. When the aspect is fixed on offset bracket using 'U' bolts and nuts, a through bolt shall be provided by drilling of hole in the signal pole to prevent the offset bracket from sliding down. (Supply of surface base, offset bracket, CLS pole, CLS aspects complete, ladder with shoes and platform, LED aspects, current regulators and wire coils will be supplied by Railways). ('U' bolts and nuts, through bolts and nuts, cement, stone jelly 20/25mm dia, river sand, Signal Colour Rings, all fixing bolts and nuts, teak wood, paints PVC/Nylon sleeves, enamelled number plates, enamelled marker boards, EWS locks, and all other miscellaneous materials for the work shall be supplied by the contractor). @ 40<37@ Payment after completion of work mentioned at (a) and remaining 40 % after completion of work at (b)) 36

40

15360

614400

... More
Cable laying and meggering.

-

-

6624000

... More
Fixing of Offset brackets using 'U' bolts and nuts, erecting of Calling On Signals!'A' marker lights, termination of tail cables and wiring, provision of EWS lock, number plates! markers 37 boards and painting. The work also includes drilling suitable holes on the CLS post and provision of a through bolt with nut to prevent the Off-set bracket from slipping down. (Supply of Calling On Signal / 'A' marker light, LED aspect! holders and bulbs, wire coils and off set brackets will be supplied by Railways). ['U' bolts and nuts, through bolts with nut, EWS lock, Enamelled number plates, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the contractor.

32

1998

63936

... More
Provision of foundation for the signal warning boards! calling on boards/all types of boards. (A pit of size 400 mm x 400 mm x 1500 mm is to be dug and cement concrete foundation in the pit in the ratio 1:3:6 to be casted. The rail post/MS angle is to be erected up right in the foundation.

20

1563

31260

... More
Supply, erection and fixing of retro reflective type BPAC Warning boards/lBS Legend 39 Board of size 1000X600X3 mm. The boards shall be provided with Retro Reflective type BPAC Warning boards. MS Angle, stone jelly of size 20 I 25mm dia, river sand, cement, fixing bolts and nuts, paint and all other miscellaneous materials required for the work shall be supplied by the contractor. (Inspection by consignee)

4

9564

38256

... More
Supply and Filling sand in trench/under floors/OFC chambers, complete as per instruction of engineer in charge

150

1562

234300

... More
Excavation of coil pit up to a depth of 1 meter and dia of 1.5 meter for providing coil at location box, point, signals etc., This includes back filling and ramming of trench / pit after laying the cable and consolidation of soil.

500

1796

898000

... More
Supply and laying of powder coated MS Ladder of 400mm width made of MS angle 42 38mm X 38 mm X 3 mm on FOB or any other location as per instructions of engineer in charge for taking of cables from one end to other end of FOB with all required materials, tools and consumables. (Inspection by Consignee)

300

4500

1350000

... More
Provision of 2 Machine cut grooves in parallel at a separation of 8 cm each to a depth of 150 mm in the platform surfaced/tiled floor for laying cable including disposal of excavated earth.

800

674

539200

... More
Videography of work spots such as Signal/LB foundation, cable trench with depth indicators at every 10 mtrs with reference to landmark such as RE mast or hectometre post in MPEG or any other format specified by engineer in charge. The video recording shall be supplied in CDs/Pen drive.

20

-

9200

... More
Supply, painting and fixing of gland plate for Location box as per site requirement. (a)Full Location Box (Inspection by Consignee)

400

776

310400

... More
Excavation of pit in and around the existing location boxes very carefully without damaging the working cables and shifting and turning the location boxes to clear of the infringement a s instructed by the Railway representative at site.The work includes, ensuring the safety of the 47 signalling system, releasing the cable coils to give access for shifting/turning the location boxes. Necessary masonry work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative at site. If the existing earth connections to the location boxes are disturbed, the earth wires shall be properly reconnected. [All materials required for the work shall be supplied by the Contractor]. (a) Shifting of apparatus case (Full)

100

4053

405300

... More
Alterations to painted termination! wiring particulars of functions in the existing apparatus cases, cable termination boxes, etc., on the PVC/ nylon sleeves and painting of new 48 nomenclature on the existing signalling gadgets. This work includes carrying out alterations of particulars on the inner side of the doors of apparatus cases, re-numbering of apparatus cases and cable termination boxes (Paints and all other miscellaneous materials required for the work shall be supplied by the Contractor).

-

-

106230

... More
Applying two coats of paint of approved colour with paint manufactured by Asian/British/ Johnson & Nicholson as instructed by Engineer In charge.

2000

170

340000

... More
Supply and fixing of location box particulars in prescribed format, particulars to be printed on a good quality flute board, location particulars will be supplied in a register by Railways. 50 Same will be provided back in A4 format sheet for check print, after finalizing check print, final particulars to be supplied and fixed as described above (Soft copy to be given to drawing office on a suitable storage device - Pen drive of suitable capacity) and also make hard copy of location particulars to be supplied in A4 format.

300

762

228600

... More
Supply and installation of "FRANKLIN ROD" as per NFPA- 780 Standards. Installation to 52 be done as per SCR Drawing No.5777. It also includes connection of down conductor with Franklin Rod and running of down conductor through PVC pipes and connecting the same to nearby earth electrode. All material required for installation to be supplied by the contractor.(Inspection by Consignee) 53

6

66720

400320

... More
Routing and connecting all the equipments in the equipment/relay room to MEEB/SEEB 54 with 16/10 sq mm copper cable using copper lugs with stainless steel nuts and bolts and fixtures. The work includes laying and routing the copper cable in PVC pipes/conduits and fixing them on wall as directed by engineer in charge. PVC pipes/conduits will be supplied by Railway.

1500

34

51000

... More
Provision MS flat connection from Earth pit to LBs/Signals including supply and laying of MS Flat of size 40X6mm at site, supply of GI bolt of size M12X40mm with two Nuts along with two 55 plain washers and one spring washer, drilling of holes in MS flat of different sizes at site, cutting with bending and twisting of MS flat as required at site, painting of MS Flat with one coating of red oxide as primary and two coats of anti-corrosive black paint and drilling of holes in Location Boxes at site. (Inspection by Consignee)

2500

294

735000

... More
Fixing of offset bracket using 'U' bolts and nuts erection of posts type shunt signal, wiring of LEDs, termination of tail cables, provision of EWS lock, fixing of number plate and painting of 57 one coat of red oxide and two coats of aluminium / enamelled paint. The work also includes drilling suitable holes on the CLS post and provision of a through bolt with nut to prevent the offset bracket from slipping down (Supply of Post type shunt signal, LED unit is to be supplied by Railways). EWS locks, enamelled number plates, bolts and nuts, lead wool, paints and all other miscellaneous materials shall be supplied by the contractor).

90

2364

212760

... More
Fixing of junction type route indicator - 1 way to 6 way - complete / fixing of additional limb to the existing route indicators, termination of tail cables, wiring as per approved circuits 58 diagram, provision of required number of EWS locks, wire mesh and painting. (Supply of junction type Route Indicators - complete and additional limb is not covered in this schedule). [Fixing bolts and nuts, EWS locks, wire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the contractor].

-

-

61511

... More
Fixing and wiring of Multi lamp! Stencil type route indicators - complete, termination of 59 tail cables, wiring as per approved circuit diagram using wire PVC 3/0.75mm & 16/0.2mm copper, provision of EWS - required Nos., and painting. (Supply of route indicators is not covered in this schedule)[Fixing bolts and nuts, EWS locks, wire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor].

21

3868

81228

... More
Removal of existing CLS units, fixing of new CLS units with LED aspects, up to four 60 aspects, directly or using off set brackets duly drilling holes on the signal poles, provision of EWS locks wherever necessary, termination of tail cables, wiring and painting of aspect. The new tail cables shall be taken through the signal poles and the unwanted cables duly released. [EWS locks, paints and all other miscellaneous materials shall be supplied by the Contractor].

40

8400

336000

... More
Provision of SCREEN on signals when they fall within 2 meters from the live conductor 61 by expanding metal (size 20mm x 60mm strand 3.25 mm wide and 1.6mm thick) as per the instruction of site engineer in charge. This includes supply of all materials including connection with earth electrode as per SCR Dig. No. 5767.

25

4194

104850

... More
Painting of existing colour light Signals as per standard practice. The work involves scraping of old paint and two coats of Aluminium! enamel paint on the Signals & White paint inside signal unit and X mark on signal unit backside with white paint - complete as instructed by Railway representative at site (Paint and all other miscellaneous materials required for the work shall be supplied by the Contractor).

-

-

62

... More
Supply and fixing of cross bar on signal (signal not in use) made of hard wood of size 1000mm x 100mm x 20mm. The cross bar shall be painted white as per Signal Engineering Manual. All material required for installation shall be supplied by contractor.

75

487

36525

... More
Fixing and wiring of platform repeaters. The work involves fixing of platform repeater using suitable fixing arrangements at places indicated, wiring the same and painting as per the 64 instructions of Railway representative at site. The signal shall be connected to the apparatus case using cables neatly clamped. The work also includes provision of one EWS lock. (Laying of cable, supply of repeater signals and cables is not included in this schedule). [Required paint, EWS lock and all other miscellaneous materials required for the work shall be supplied by the Contractor].

10

5162

51620

... More
Excavation of pit in and around the existing signals very carefully without causing damage to the working cables and shifting the Signals along with the concrete foundations for 65 approximately im to a nearby position so as to clear the infringement from the nearest track centre as instructed by Railway representative at site. The existing cable coils shall be released carefully so as to give access for shifting. Necessary masonry work and earth work shall be carried out in and around the signals after shifting as Instructed by Railway representative at site. [All materials required for the work shall be supplied by the Contractor].

25

3627

90675

... More
Strengthening of foundations of signals, Full/Half location boxes up to a height of 30 66 cm, by carrying out the earth work around the foundation, ramming of the earth, carry out masonry work from bottom of earth work using country stones and cement masonry to prevent the earth from slipping down the bank.

150

760

114000

... More
Painting of particulars of Glued Joint on rails/track circuit no. on TLJ boxes as per 68 particulars issued by Engineer in charge. Before painting on surface of the Glued Joint Rails/TLJ boxes shall be cleaned thoroughly. Painting shall be done with approved quality of standard paints like Asian/Johnson/ Nicholas /Berger etc. All the men and materials shall be arranged by the contractor and the colours scheme shall be as per the instructions of Engineer in charge.

1200

149

178800

... More
Providing and fixing of Speed board on signal post complete with retro reflective sheeting over the board and with all fixing arrangements of size 900mm equilateral triangle made of 2 69 mm thick aluminium sheet and back support 25mmx3mm MS flat with theft resistant measures, mounted and fixed with 2 Nos. M.S. angles to suit Signal post. Backside of aluminium sheet to be painted with two coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing, specification and direction of Engineer-in-charge.

10

3627

36270

... More
Supply & Fixing of block test panel of teak wood of 25mm thickness (61 x 38 x 18 Cms) 71 with glass door. This includes wiring of block test panel to block instruments and the line (CTB) on the wall using PVC conduit. (Supply of PVC conduit and all other miscellaneous material required for installation is in the scope of contractor) (Inspection by Consignee)

2

4897

9794

... More
Supply & Fixing of Control Equipment Panel of Teak Wood of size 3/4" thickness (75x44x25 mm) with reaper frame (Inspection by Consignee) 73

2

2870

5740

... More
Crank Handle Box KLCR Box for Crank Handle

-

-

571200

... More
Manufacturing and fixing of glass fronted box ( key box) made out of teak wood of size 406X254X75 mm.(Inspection by Consignee)

-

-

74

... More
Fixing of PVC pipes & bends, drawing of required wires through the same up to 75 functions like control telephone, Dy.control telephone, magneto phones inside SM's office as per circuit diagram. This includes supply and fixing of required DPDT and rotary switches, PVC pipes and bends 25mm dia with 2mm wall thickness, Lightening dischargers and painting of particulars.

7

5406

37842

... More
Fabrication, supply and fixing aluminium ladder of size 25 X 25 X 5mm, 200mm width, arrangements for drawing various wires in the battery, equipment and relay rooms. (inspection by consignee)

300

703

210900

... More
Fabrication and supply of powder coated (of approved colour) MS frames for Location 78 boxes of size 955X155 mm and made of L angular of size 25X25X3 mm to suit 'Q' series relays duly drilling required holes for relay bases (All materials such as frames, bolts, nuts and washers to be supplied by the contractor)(inspection by consignee)

200

439

87800

... More
Installation, testing and commissioning of Data Logger which includes the software configuration, validation, taking test print, networking to nominated location for monitoring, changing of EPROMS if any and alterations to data base in HQ/SSE offices where ever required.

7

36208

253456

... More
Alteration of database, faults, simulations in Data Loggers and all connected places (like HQ, FEP, STATION etc.,)

1

28114

28114

... More
Providing and laying vitrified floor tiles in different sizes with water absorption less than 82 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq m including grouting the joints with white cement and matching pigments etc., complete. (a)Size of Tile 500x500 mm 83

250

1014

253500

... More
Fabrication of Keys and Plate configuration for points

-

-

122170

... More
Provision of temporary signalling arrangement during Non Interlocked working of 84 Signals and Points, such as erection and wiring of temporary relay racks and wiring of relays, SM's slide instruments, wiring alterations in the cable termination rack, apparatus cases, signals, Control panel etc, as per the instructions of Railway representative at site. all other miscellaneous material shall be supplied by contractor

2

25451

50902

... More
Arranging skilled labour at S&T Stores for loading/ unloading/ stacking of departmental materials.

-

-

87

... More
Installation and wiring of all power supply equipment viz DC Distribution system, 89 chargers, Transformers, batteries etc, and its wiring (lacing, button/ thread copper eyelets/lugs required for crimping 10 sq.mm wire are to be supplied by contractor). For power panel, bolts, nuts, fixing screws are to be arranged by contractor. ON/OFF Switches, digital Meters, Hylam sheet and wire coils will be arranged by railways.

6

16629

99774

... More
Installation of DG Set (a) Foundation, Erection, Wiring, changeover arrangements in Generator room and commissioning as per Technical Specification for Installation of two generators of capacity up to 20 KVA.

1

45819

45819

... More
Installation, wiring, earth connections with SEEB, testing and commissioning of IPS 91 system. Wires/cables shall be supplied by Railways, Charging of battery is covered elsewhere. Minor items like casing/capping, Ladder, insulators, Lugs, Lacing of cables etc., where required to be supplied by contractor. Grouting and masonry work of the IPS to be done. Work includes installation of charged batteries and their wiring with IPS.

6

21746

130476

... More
Installation, Calibration and commissioning of Earth Leakage detector 8 to 12 channels as per instructions of engineer in charge

6

11802

70812

... More
Supply and wiring of Polymeric Positive Temperature Co- Efficient Device self resetting 93 type (PPTC) of 2A rating suitable for railway applications of reputed make. The PPTC fuse shall be wired by soldering suitable flexible wire on both ends (all material except flexible wire has to be arranged by contractor).(inspection by consignee)

1200

87

104400

... More
Testing to check integrity of gears (Field correspondence) i.e. One Signal Unit (with or 95 without route)/Track Circuit/LC Gate/One Point machine/One Block Instrument/One Slot etc. This item will be applicable after one round of complete testing of gears by the contractor in presence of Railway Supervisor.

600

103

61800

... More
Foundation, Erection ,Testing and Commissioning of Electrically operated lifting barriers assembly, drive mechanism, motors etc. as per technical specification, with control panel, boom locking arrangements & crank handles complete with Hand generator .The work includes excavation of 97 pit and concreting foundation for pedestal-2 no's ,Excavation of pit and concreting foundation for meeting post-2 no's, Erection of Electrical Lifting barrier-I Set, Fixing of EOLB Panel and its wiring-i No., testing and commissioning as per detailed technical specification and instructions of site in charge. (75 % of payment will be made after foundation, erection & testing and 25% Payment after Commissioning).

1

30145

30145

... More
Supply and fixing of 'AHUJA' or similar make horn type loud speaker 15W 8 ohms impedance at LC gate Road signal. (Inspection by Consignee)

2

1407

2814

... More
Supply and installation of Electronic Flasher unit, able to drive 2 No. of flasher lights. (inspection by consignee)

2

2572

5144

... More
Supply and fixing of Electronic Hooter unit 24/110 DC of approved design/make able to drive 2 No. of Speakers of 8 ohms 15W. (Inspection by Consignee)

2

2732

5464

... More
Excavation of a pit and concreting foundation for 1 No. of lifting barrier gate winch using anchor bolts of size 20 X 450mm. Concrete ratio is 1:3:6 (cement will be supplied by the Railways).

1

2049

2049

... More
Supply of paint of approved quality (Asian, Berger, Nicholson) and painting of complete 102 sliding boom arrangements and accessories (Rectangular boom movement stand, pillar supports, resting stand with one coat of red oxide and two coats of Yellow/black enamel paint & Yellow colour retro reflective tape (HIP) with width of 12" and as directed by engineer in-charge at site.(Inspection by Consignee)

1

7930

7930

... More
Fabrication, supply, transport, erection at site, sliding boom mechanical type, make 103 assembly, movement drive mechanism, resting stand and meeting post. Rates included for all required nut & bolts, chains, padlocks 2 No's and other miscellaneous are supplied by contractor (Inspection by Consignee)

-

-

204027

... More
Installation (including power supply arrangements if required), testing and commissioning of SSDAC/HASSDAC.The work consists of: a) Fixing of axle counter track device consisting of Tx-Rx coil assembly for each detection point drilling holes in the rails as per the marking 104 given by the site in charge. b) Fixing of rails deflector plates on either side of each detection points as per the marking given by the site in charge. c) Fixing of evaluators inside pre-erected location boxes on the nominated planks along with VR assembly duly providing anti-vibration arrangements, fixing terminals and wiring as per the instructions of site in-charge. d.) Routing cables from Tx/Rx coil assembly through pre laid GI/HDPE pipe arrangements of track crossing and entering the location box and termination (60 % Payment after installation & Testing and 40% after commissioning).

2

37152

74304

... More
Design of SIP in Auto Cad. Initially, contractor shall submit 3 copies for approval of Railways. One set will be returned duly approved for making a fair copy or for re-submission for 105 approval after incorporating the changes as required by Railways. After carrying out changes, three Hard copies to be submitted for Railway Approval. After approval, Auto Cad copies to be submitted in USB pen drive along with approved copy in Tracing film and six copies of final approved drawing (Ammonia Print or print as approved by Railway) in properly bound booklet along with its scanned copy. (g) For a Eight-Line Station or more

1

80280

80280

... More
Design of SWRD in Auto Cad. Initially, contractor shall submit 3 copies for approval of Railways. One set will be returned duly approved for making a fair copy or for re-submission for 106 approval after incorporating the changes as required by Railways. After carrying out changes, three Hard copies to be submitted for Railway Approval. After approval, Auto Cad copies to be submitted in USB pen drive along with approved copy in Tracing film and six copies of final approved drawing (Ammonia Print or print as approved by Railway) in properly bound booklet along with its scanned copy. (g) For a Eight-Line Station or more

1

34254

34254

... More
Design in AUTOCAD and submission of two draft copies of Complete Outdoor Particular such as Cable Route Plan, Cable Corage Plan, Cable Termination Rack/Power Rack Particular, Track Bonding, and Location Box Particular along with NI wiring/NI Relay Disposition chart. One copy will be returned either duly approved or for resubmission for approval after incorporating the changes as 108 required by Railways. After approval, one approved Tracing film copy & six copies (Ammonia Print or print as approved by Railway) of above drawings along with six copies of SIP and SWRD in Plastic Covers. All above drawing to be scanned including SIP & SWRD, bound in 6 different booklet with Rexin Cover (Each booklet shall have minimum 10 spare plastic transparent sheet) and a soft copy to be submitted in a Pen Drive for following categories of Stations: (g)For a Eight-Line Station or more (Up to 110 Location Boxes)

1

155906

155906

... More
Design of Cable Route Plan (Distant to Distant) including details of all track crossing/Horizontal boring/Cable Loop! Cable Joints etc. in AUTOCAD & submission of coloured paper 109 copies for approval. After approval, Auto Cad copies to be submitted in USB pen drive along with approved copy in Tracing film and six copies of final approved drawing in plastic cover (Ammonia Print or print as approved by Railway) in properly bound booklet along with its scanned copy.(g)For a Eight- Line Station or more

1

26714

26714

... More
Scanning of Documents from the approved Tracing film 112

-

-

14500

... More
Fabrication and Supply of Different Boards (Inspection by Consignee)

-

-

309173

... More
Supply and fixing of Fire Extinguisher CO2 type (Capacity 4.5 KG) (Inspection by Consignee)

20

8171

163420

... More
Removal of existing 'Q' style/K-50 contact clips along with its wire from the relay base 115 by carefully tracing out from the bunch of wires and taking out unwanted wires from the same as per the alterations shown in the circuit diagram issued by Railways. Drawing of fresh new wire from the relay base to another relay base as per the new wiring as shown in the circuit diagram without affecting the other wires. This also includes testing of wires using buzzer of the new wires drawn once before soldering, once after soldering (This includes of wires required for data loggers.)

2000

112000

112000

... More
Fabrication, Transportation and fixing of aluminium ladder at site made of Aluminium angle of size 38mmx5mm width 280mm ,Flat size 25 mm x 5mm with powder coated colour as 119 desired by engineer in charge at site and fixing, Drilling of suitable holes for fixing of Hylam sheet 3mm thickness on ladder and 2 No's of PVC trough 100 mm with cover fixed on Hylam sheet along the ladder with all fixtures necessary ancillary materials required for fixing to be supplied and as directed by engineer in charge at site.(Inspection by Consignee)

300

4098

1229400

... More
Supply and installation of offline UPS 1000VA, 30 min backup as per instructions of engineer in charge. (Inspection by consignee)

10

11286

112860

... More
Supply, Installation, Testing & Commissioning of 2X1.5sqmm ATC Fire survival 121 flexible/armoured cable with back box, glands & other accessories. Armoured & unarmoured (Cl) cables should meet fire performance test under simultaneous action of Flame, water stress and impacts on single sample at 950°C for minimum 2 hours, certified by LPCB or equivalent complying to RDSO/SPN/217/2016 Ver. 1 or latest (Inspection by Consignee)

6

60016

360096

... More
"Fabrication and supply of wall mounted maintainer's Tool Kit frame made out of MS 122 sheet 10 gauge with powder coated as desired colour at site of size 1.5 Mtrs. Length X 0.8 Mtr. Width X 0.15 Mtr. Depth with all fixtures for mounting individuals, tools inside the board and in front with Acrylic sheet 4mm thickness with locking arrangements and all necessary fixtures to fix on wall." (Inspection by Consignee)

6

18699

112194

... More
Arranging of skilled and unskilled workers with required tools during point blocks for removal of S&T assets to give way for track machines and refixing the removed assets after insertion/removal of point

20

4102

82040

... More
Provision of one skilled and 2 unskilled staff round the clock to attend to teething trouble of the installation along with Sl/CSl after the installation has been brought into commissioning. The work includes routine maintenance, failure restoration as per the direction of the Sl/CSI

6

64951

389706

... More
"Supply and installation of 45mmx 45mm PVC channels for drawing switchboard cables at OFC cable huts and at stations as indicated by Railway Engineer at site."(Inspection by Consignee)

1000

102

102000

... More
Installation, wiring, testing & commissioning of 2 wire DTMF Selective Calling Telephone with power supply.

20

922

18440

... More
"Fixing of 12/10 pair weather proof C.T. Box WAGO type and termination of 6 quad jelly filled cable on teak wood plank of size 375mm x 250 mm x 20 mm thickness"

20

340

6800

... More
Installation and commissioning of 4 Wire way station control equipment as detailed below: a) The way station equipment & Power supply unit are to be mounted on a rack as per Drg. No. 132 CORE/S&T/ ALD /SK/436/95. b) The internal wiring should be wired between VF Repeater/ VF Transformer bay and MS Angle rack then to be extended to Dy.SS/ASM Table as per drawing shown in the sketch (All the wiring materials are to be provided by the contractor) except way station equipment & power supply unit

2

3922

7844

... More
"Supply & installation of Rack 19"" wall mount 17U with front glass door and lock and 133 key including the following: 1. 1 U Cable manager - 1 No. 2. 1 U Cantilever tray - I No. 3. AC distribution box 5X5 amps - 1 No. 4. Front panel H/W PKT of 10 Sets - I No. 5. Cooling fan of 230V AC operated" (Inspection by Consignee)

8

17545

140360

... More
Laying of HDPE duct 40/33 mm dia in the trenches and in protective works already provided.

10

7410

74100

... More
Blowing of armoured optic fibre cable (OFC Cable supplied by Railways) into the duct supplied vide other NS item of supply portion by using blowing machine and associated works. 10% of 135 OFC length to be blown extra on both ends of Duct i.e. total 20% of Duct length. Before blowing the duct integrity shall be tested. If any defect is found during duct integrity test, the entire length of HDPE duct from one chamber to another chamber is to be replaced by the contractor at his own cost. Payment will be made as per the length of Duct from which OFC is Blown.

10

10956

109560

... More
Excavation of jointing pit and provision of RCC/FRP joint /Loop chambers of 90 Cms. Inner dia 60 Cms depth and 3mm thickness with two pieces of top cover with hooks each and bottom 136 cover with hole for drainage and cable entry as per Drg. No. RAILTEL/SR/OFC/ 2009/12 and as directed by Engineer to be provided at every joint location and at every Kilometre loop etc., The chamber shall be filled with sand mixed with anti-stermic power, back filling and ramming of trench after HDPE duct laying, splicing and commissioning.

30

6344

190320

... More
Supply and Installation of OFC joint enclosure and splicing of Optic fibre cable (24 fibres) and testing as per technical specification No. GR OJC-2/02 Sept 2003. Supply of Splice Enclosure (24 fibre) shall be of TVS make Part No.1500-L18X-XX or similar as per Board specification of TEC.& as per RDSO/SPN/TC/68/2014 Revision 1.0 amd 1 or latest . All materials including Fusion splicing machine used for fibre splicing and, OTDR for testing and other testing materials if any shall be arranged by the contractor. (Inspection of Consignee)

15

9398

140970

... More
Supply and installation of rack mounted 24 fibre Distribution Management System 138 (FDMS) of size 1U, of Reputed/Branded company make as per specification RDSO/SPN/TC/37/2020 Revision 4.0 with latest amendments. The FDMS shall include 24 SC-PC/Required adaptors having insertion loss less than or equal to 0.1dB and 24 numbers 900 micron 1.5m SC-PC/Required pigtails. (Inspection by Consignee)

15

23712

355680

... More
Testing of fibres between short haul station in both direction after splicing the required fibres

6

7769

46614

... More
"Supply and fixing of different sizes of PVC casing /Pipes as required by Railway at site by fixing /clamping to the wall for indoor wiring purposes. All the material required for fixing PVC casing/Pipes are to be supplied by contractor. "

500

48

24000

... More
"Supply and installation of 230 volts AC / 48 volts, 25 Amps DC (2 + 1 configuration) SMPS battery charger as per RDSO spec. RDSO/SPN/TC/23/99 (Ver-4) Amdt.-1 or latest. ." (Inspection by RDSO)

1

83721

83721

... More
"Supply and installation of 48 volts 200 AH maintenance free VRLA battery in charged condition as per RDSO specification IRS:S-93/96(B) (Amd. 1 ) or latest. (2 volts 200 AH - 24 Nos. each set)." (Inspection by RDSO)

1

104042

104042

... More
Supply and installation of 19" - 42 U Rack complete with fittings for housing SDH equipment, FDMS, DDF and other equipment like cable managers, completely wired using krone module and other equipment like runaway ladders etc., as per technical specification below. It should be able to lock all the equipment with only order wire Telephone outside the rack. The rack should be 143 of APW President / Rittal make or similar. The components of the rack are specified below. It includes transportation and installation of rack in prefab/building at specified stations. 1. Rack S33 42U 600'W x 600D - 1 No. 2. Fixed side panels 42U x 600 D - 2 Nos. 3. Front Glass door plain 42U/600W - 1 No. 4. Rear MS Door Plain 42U/600W - 1 No. 5. Castor with brakes-2 Nos. 6. Fans directly mounted on the top 48V DC 90 CFM-2 Nos. 7. Krone mounting bracket - 01 Nos. 8. MCB Mounting panel with MCBs - a. 32 Amps, MCBs(DP) - 2 Nos. & 6Amps MCBs (DP) - 6 Nos. 9. Earth continuity Kit - 01 No. 10. Equipment Trays - 5 Nos. 11. Channel with cable loops 42U - 2 Nos " (Inspection by Consignee)

6

41962

251772

... More
"Supply, installation, testing and commissioning of managed expandable rack type STM-4, equipped STM-1, ADM S1.1, as per technical Specification no.GR No.: TEC/GR/TXISDA- 003/02/APR-2010 with 2 Nos.STM-1 aggregate Optical interface upgradable to STM-4, 21 Els, and minimum 8 Nos. of 10/100 base T Ethernet port, Order wire, Power supply unit, sub rack, DDF, 144 Installation materials, manuals and other accessories. The equipment should be TEC/BSNL/RDSO approved .The equipment should be fully wired for its ultimate capacity and provide redundancy for Power supply and Synchronisation. It shall be possible to use the full capacity of the equipment by adding additional tributary cards. The up gradation of STM-1 to STM-4 shall be without change of any internal hardware of the STM equipment. The STM equipment shall have in-built L2 switch for Ethernet ports. Make -Tejas or similar." (Inspection by RDSO)

1

311694

311694

... More
"Supply and installation of programmable Primary Digital Drop Insert Multiplexer fully wired for 30 Channels complete with all accessories from RDSO approved vendor as per RDSO specification IRS TC 68-2012 Rev.0 (with latest amendment) including connectors and cables required for installation including 100 pair Krone type MDF. Each channel card shall have minimum four channels per card. The single sub rack shall be capable of being equipped up to min. 60 Channels 145 without additional power supply unit. The MUX shall be wired & equipped with following circuits: 1. 2 Wire/4 Wire E&M VF circuits (Minimum 16 No. Ckts) 2. FXO circuits: 6 nos. 3. FXS circuits Subs/Hotline circuits along with ringer card 4. Acquisition card as per design 5. Data User manual. 6. This also includes connecting all pigtails, optical patch cords etc to the SDH equipments. This also includes connection of SDH and primary MUX equipment with all interface cards to the 48V Bus including termination on DDF taking PVC cable over runway or a wall and termination of VF interface circuits to the Krone Termination box. " (Inspection by RDSO)

2

274869

549738

... More
Supply & erection of lattice type tripod towers of GI 15 meters of height as per SCR 146 Drawing No. SC 23000 23012, casting of foundation with 1:2:4, 20mm metal and river sand to be used. Provision of earth electrode near the tower and connect the same to tower which is to be erected above the station building/at the site shown by the site Engineer of the Railways. Cement shall be supplied by Rlys. Work includes installation of the antenna, drawing the cable and installation of the battery and 25W set and commissioning the system. 25W set, cable, antenna, battery will be supplied by Rlys. (Inspection by Consignee)

1

41930

41930

... More
Supply and installation of ONVIF 16 Channel NVR similar to Model No. 4416-4KS2 series along with required licensed video management software compatible to work with Dahua/Hiki vision/CP Plus/ Honeywell make 4 MP Bullet cameras. (Inspection by Consignee)

1

30887

30887

... More
Supply of All in one data analyser tool - HP All-in-One PC 11th Gen Intel Core i5 23.8 inch@ 40<46@ 5cm) FHD Anti Glare 8GB RAM, 512GB SSD, Intel Iris Xe Graphics, Wireless Keyboard and Mouse Combo (Win 11, MSO21, Snow White, 5.85Kgs) 24-df1229in - Brand HP Operating System Windows 11 Home, Screen Size 23.8 Inches, RAM Memory Installed Size 8 GB, Model Name 24- df1229in, Included Components Desktop PC, Wireless Keyboard & mouse, CPU Model Core i5, Colour Snow White Special Feature Webcam, Processor:Intel Core i5- 1135G7 (up to 4.2 GHz with Intel Turbo 1 Boost Technology, 8 MB L3 cache, 4 cores)| Memory:8 GB DDR4-3200 MHz RAM (1 x 8 GB| Storage:512 GB PCIe NVMe M.2 SSD, Operating System & Software: Windows 11 Home| Microsoft Office Home & Student Edition 2021, Display & Graphics: 60.5 cm (23.8") diagonal, FHD (1920 x 1080), IPS, three-sided microedge, anti-glare, 250 nits, 72% NTSC| Graphics: Intel Iris Xe Graphics, Ports:2 SuperSpeed USB Type-A 5Gbps signaling rate; 2 USB 2.0 Type-A; 1 HDMI-out 1.4; 1, headphone /microphone combo; 1 RJ- 45 Features: Webcam: HP Wide Vision 1080p FHD IR privacy camera with integrated dual array digital microphones| Networking:Realtek RTL8821CE-M 802.11a/b/g/n/ac (1x1) Wi-Fi and Bluetooth 4.2 combo. (Inspection by Consignee)

4

55490

221960

... More
Supply 35 Sq. mm 2 core LT XLPE copper conductor cable as per IS 7098 part-1 (Inspection by RITES)

20000

1085

21700000

... More
VHF Communication system & Power Supply arrangement at a Station as per RDSO/SPN/TC/73/2008, Ver.-1.0 Or latest.(Inspection by Consignee)

-

-

67264

... More
Supply of Addressable Monitor Module as per RDSO Spec. No. RDSO/SPN/217/2018 Ver. 2.0 or latest. (Inspection by RDSO)

6

7017

42104.94

... More
Supply of Office table with plywood plank with thickness of 18mm, teakwood beading with three draws of size 4' X 2' with heavy duty 'S' type chair with hand rest. The above is of Godrej or similar make.( Inspection by Consignee)

6

7035

42210

... More
Supply of Plastic Cover for 2/3/4 Aspect Signal Unit Cover Operated from front side & 6 bottom side and make of Black polythene sheet of 100 microne thickness size of 1200MM x 460MM x 205MM and Back side 75MM wide cornor to cornor Diagonal mark of silver color of 100 Micron thickness to be provide total up cover with signal unit suitable nylone rope of 5MM dia and 4 meter length to be provide on front side and of 1.5 meter length at centre. (Inspection by Consignee)

50

130

6504.5

... More
Supply of Clamp Point lock along with Ground connections suitable for 220 mm Electric Point machine as per Drg. No. RDS0/S-3454 ALTB (P- BRACKET TYPE) along with Ground connections. 7 Note: 1. Layout 1 in 12 BG 60Kg. On Pri- stresed concrete sleepers fitted with IRS point Machine (220 mm stroke) for independent switch locking and clamp point with P- bracket. - RDSO/S 3454 ALT-B 2. Layout 60KG (TWS) IRS Pt. M/c Detector rod Long - RDSO/S 3594 Alt-1 3. Layout 60 KG (TWS) BG IRS Pt. M/c Lock rod Long - RDSO/S 3596 ALT-1 4. DROP LUG FOR DETECTOR ROD - RDSO/S 3598D 5. LAYOUT - BG - DRIVE ROD LUG - RDSO/S 3461 ALT 3 TO BE INSPECTED (Inspection by RDSO)

20

53100

1062000

... More
Nylon Insulation Kit for Crompton/High Trust/TWS Point Machine. One set of item as given below. enclosed and as per RDSO drawings One set of Nylon Insulation Kit for TWS point machine consists of: (1) Plate to RDSO Drg.No.53404:2 Nos, (2) Stretcher bar bush RDSO Drg No.523199:12 Nos, (3) Flat washer RDSO Drg.No.S8640:12 Nos. (4) Throw Rod bush RDSO Drg.No.S3436:1No, (5) Flat washer RDSO Drg.No.58640:2 Nos. (6) Lock rod bush RDSODrg.N0.522179:2 Nos. (7)Washer RDSO Drg.No.56840/1: 04 Nos. (8) Detection rod bush RDSO Drg.No.523199: 02 Nos. (9) Flat washer RDSO Drg.No.S6840/1: 04 Nos and (10) MS Flat washer: suitable to RDSO No0.58640: 16 Nos, Suitable RDSO Drg.No.58640/1: 04 Nos, Suitable for RDSO Drg.No.S4680/02: 04 Nos. (TO BE INSPECTED BY RITES)

-

-

8

... More
Nylon -66 Point insulations complete set With RDSO spec No-IRS-S-40/84 or latest consists of 1.Gauge tie plate insulation one set (Insulating plate drg No. T-10372=01No,insulating bush drg No. T-10368=03 Nos, insulatingwasher drg No. T-10371=06 Nos) 2. D bracket insulation one set (Insulating plate (RH) drg No. S-3265=01No, insulating plate (LH) drg No. S-3266=01 No, 9 insulating washer drg No. S- 8640=04Nos, Insulating bush drawing No.S- 23199=04Nos) 3.Stretcher bar insulation one set (Insulating plate drg No.T- 10367=01No, insulating bush drg No.T- 10368=02Nos, insulating washer drg No.T- 10371=04Nos) 4. L-bracket insulation one set (Insulating plate drg No.S-8804=01No, insulating washer drg No. S -8640=02Nos, insulating bush drawing No.S- 8813=02Nos) Inspection by RITES. Note : The type of insulation required will be specified by engineer incharge of the work depending on the type of machine proposed.(Universal/ PT] Make) as per spec. (TO BE INSPECTED BY RITES)

20

459

9180.4

... More
Supply of Lockbar assembly complete of Point machine 220 mm clamp lock device with 10 M. S. Plate (Thich and thin) and insulation plates, bush, washer and its hardware shall be supplied as per latest RDSO DRG No. RDSO/S 3462A & Drg No. RDS0/ 3404A for 1:8.5 (TO BE INSPECTED BY CONSIGNEE)

20

4130

82600

... More
Supply of 15 U rack wall mounted of VERO President make or similar with cooling fan, power manager with 5 sockets,1 equipment tray, earth connecting kit (Inspection by Consignee)

8

7620

60960

... More
Supply of 0.5 mm annealed tinned copper conductor PVC inculated and PVC sheathed switch board telephone cable, 10 pair, as per Specn. No. TC 24/91 to be procured from RDSO approved firms. (Inspection by Consignee) 13

500

31

15500

... More
Fuse Links 0.6 Amps (Inspection by RDSO)

450

21

9450

... More
Supply of Speaker Cable 2 core PVCs heathed & Screened of size 47/0.193as per specification No. IS-694 or with latest amendment / spec if any. (Inspection by Consignee) 15

600

36

21900

... More
Supply of PA column speakers Ahuja make ASC 20T or latest (Inspection by Consignee) 16

10

1285

12850

... More
Supply of Micro phone AGN-5-- (Make: Ahuja) Inspection by Consignee

10

1395

13950

... More
Supply of self regulated battery charger 230V AC / 12V DC 10 Amps. to RDSO Specn. No. IRS S.86/2000. (Inspection by RDSO)

2

29724

59448

... More
"Supply of 24U Rack of HCL/APW make as per Specifications • Supply of 24 U Rack 18 19'/800 MM depth Floor standing 2 P FAN with tray - 1 No., • Horizontal cable manager - 2 Nos., • Vertical power manager with fuses - 1 No., • Hardware Packets - 2 Nos., • Equipment Tray 600mm D - 4 Nos., • Casters set - 1 No. (Inspection by Consignee)

6

20060

120360

... More
Supply of following items for stations a) Supply of Godrej T-104 model or similar (Inspection by Consignee)

14

20569

287966

... More
Supply of independent non-vital mux with UFSBI or non-vital modules with FN-Mux for gathering I/O towards display of tracks, signals and LC Gates etc (Inspection by Consignee) 21

6

194700

1168200

... More
Supply of Ferrule Printer of reputed make.(Inspection by Consignee)

1

20000

20000

... More
"Supply of Linear Pneumatic Heat detection tube kit, (Standard) f o r I n - cabinet Automatic Fire Suppression System (ICAFSS) system as per RDSO specification No. RDSO/SPN/218/2016 Ver 1.0-d2 or latest (Inspection by RDSO)"

300

1969

590889

... More
"Supply of Master Control Unit ( In-cabinet monitoring panel(ICMP) for In-cabinet Automatic Fire Suppression System (ICAFSS) system as per RDSO specification No. RDSO/SPN/218/2016 Ver 1.0-d2 or latest (Inspection by RDSO)"

6

47846

287076.78

... More
Supply of FCPC to SCPC 10 meter long patch cords with 0dB adaptors as per TEC spec G/OJC- 01/03 Jan 99 or latest.( Inspection by Consignee)

200

1027

205400

... More
Supply of RFID Marker Locator, 8000 Marker records, Built in GPS Module, 1.5m Depth Range 4 X 20 Digit LCD Display. RFID Marker locator shall be provided with complete Marker Database software suitable for RFID cable markers of Item No.18 of Schedule- D(Inspection by Consignee)

1

419440

419440

... More
Supply of 8 Channel FXO&FXS card which supports 4FXO & 4FXS which suits MAPLE 4C (0) (V4) with accessories and cables. Make: MROTEK/MAPLE. (Inspection by Consignee)

12

48616

583392

... More
Supply of Data Entry Terminal for entry of Train Details by ASM as per specification A1. (Inspection by Consignee) 28

1

218331

218331.86

... More
Supply of USB to Opto Converter. (Inspection by Consignee) 29

1

5900

5900

... More
Supply of External RS232 to E1 Converter. (Inspection by Consignee) 30

1

20886

20886

... More
Supply of GDT card for DL & Test room FEP. (Inspection by Consignee)

2

5900

11800

... More
"Supply of In-cabinet Automatic Fire Suppression System (ICAFSS) s y s t e m a s p e r 31 RDSO specification No. RDSO/SPN/218/2016 V e r 1.0-d2 o r latest Direct Low Pressure (DLP-Maximum operating pressure 13.5 bar @ 21 deg ) Clean agent ( NOVEC-1230) 2 K g System, supplied complete with differential pressure valve, clean agent, Pressure Gauge, Pressure switch for monitoring system pressure, end plug with panel mounting bracket (Inspection by RDSO)"

19

326768

6208604.73

... More
Supply of Self contained breathing apparatus & Fire Protective dress as per RDSO specification No. RDSO/SPN/218/2016 Ver 1.0-d2 or latest (Inspection by RDSO)

6

202417

1214502

... More
"Supply of Motorized Fire Damper with relay arrangement for tripping of Exhaust fan" (Inspection by Consignee)

6

16667

100002

... More
Supply of C.S.Pipes forged Fittings, Manifold & Cylinder Stand with testing as per RDSO specification No. RDSO/SPN/218/2016 Ver 1.0-d2 or latest (Inspection by RDSO)

6

168825

1012950

... More
Supply of Addressable Relay Module as per RDSO Spec.No.RDSO/SPN/217/2018 Ver. 2.0 or latest. (Inspection by RDSO)

18

7017

126314.82

... More
Supply of Motion Sensor as per RDSO specification No.RDSO/SPN/ 218/2016 Ver 1.0-d2 or latest (Inspection by RDSO)

12

18667

224004

... More
Supply of Lock-Off Valve as per RDSO specification No.RDSO/SPN/ 218/ 2016 Ver 1.0-d2 or latest (Inspection by RDSO)

6

12767

76602

... More
Supply of Color-vu 4MP Bullet Camera Make: Hikvision DS-2CD 1047GO-L/ Cpplus with 38 following minimum spec: Image Sensor-1 /2.7" Progressive Scan CMOS & Lens Type & FOV 2.8 mm, horizontal FOV 102°,vertical FOV 56°, diagonal FOV 127° 4 mm, horizontal FOV 84°, vertical FOV 45°, diagonal FOV 99° (Inspection by Consignee)

100

6960

696000

... More
Supply of 24 port Giga POE Ethernet Switch with 4x1 SFP as per the specification Make: Cisco/Juniper (Inspection by Consignee)

6

45000

270000

... More
Supply of 80 Ltrs. Seamless CCOE Cylinder for gas based fire suppression system ( 50 Bar) asper RDSO specification No. RDSO/SPN/218/2016 Ver 1.0-d2 or latest.(Inspection by RDSO)

20

151942

3038850

... More
Cumulative Supply of Clean agent gas ( FK-5-1-12) to NS 1to 4 a s p e r RDSO specification No.RDSO/SPN/218/2016 Ver 1.0-d2 or latest (Inspection by RDSO)

1326

5402

7163582.4

... More
Centralized Master Cylinder Kit ( 50 B a r ) Assembly consisting of : 1. Pr.Gauge + Low Pr.Supervisory Switch - 1 Nos. 2.Electromagnetic Actuator - 1 N o , 3.Mannual c u m Pneumatic Actuator - 1 No.,4.Flexible Discharge Hose - 1 No, (Inspection by RDSO)

6

84412

506475

... More
"""Centralized Slave Cylinder K i t ( 5 0 B a r ) Assembly consisting of: 1. Pr.Gauge + Low Pr. Supervisory Switch - 1 Nos. 2.Flexible Actuation Hose - 1 Nos (Inspection by RDSO)"

14

61902

866635

... More
"Supply of Bleed Valve as per RDSO specification No. RDSO/SPN/218/2016 Ver 1.0-d2 or latest (Inspection by RDSO)"

6

11573

69438

... More
"Supply of Check Valve as per RDSO specification No. RDSO/SPN/218/2016 Ver 1.0-d2 or latest (Inspection by RDSO)"

20

50647

1012950

... More
"Supply of Nozzles as per RDSO specification No. RDSO/SPN/218/2016 Ver 1.0-d2 or latest (Inspection by RDSO)"

28

15194

425439

... More
"Supply of Wall mount Cylinder bracket a s p e r RDSO specification N o . RDSO/SPN/218/2016 Ver 1.0-d2 or latest (Inspection by Consignee)"

40

1969

78785.2

... More
"Supply of Discharge Pressure Switch as per RDSO specification No. RDSO/SPN/218/2016 Ver 1.0- d2 or latest (Inspection by RDSO)"

6

30951

185707.5

... More
"Supply of Gas Release Panel as per RDSO specification No.RDSO/SPN/218/2016 Ver 1.0-d2 or latest (Inspection by RDSO)"

6

28137

168825

... More
"Supply of Warning Sign board as per RDSO specification No.RDSO/SPN/218/2016 Ver 1.0-d2 or latest (Inspection by Consignee)"

6

8441

50647.5

... More
Supply of Manual Release Switch as per RDSO specification No. RDSO/SPN/218/2016 Ver 1.0-d2 or latest (Inspection by RDSO)

6

10210

61260

... More
"Supply of Abort Switch as per RDSO specification No. RDSO/SPN/218/2016 Ver 1.0-d2 or latest (Inspection by RDSO)"

6

10210

61260

... More
Supply of Sounder cum Strobe as per RDSO specification No.RDSO/SPN/217/2018 Ver 2 o r latest (Inspection by RDSO)

6

8441

50647.5

... More
Installation /fixing and wiring of 15U rack, drawing of cable through aluminium ladder, 1 neatly lacing the cables, fixing of earth bus bars, extending earth to various equipment through 16 sq.mm copper cable, fixing of power distribution panel with 5AC sockets. Aluminium ladder and lacing thread shall be supplied by the contractor.

7

562

3934

... More
Supply and fixing of 20mm thick teak wood planks for Keeping Equipment in the Full B o x after applying two coats of wood primer. The approximate size of the flank is 940mmx20mmx300mm (Numbers=per plank) (Inspection by Consignee)

200

490

98000

... More
Supply, Installation, Testing and Commissioning of Copper Plate Earthing System complete with provision of (i) Copper plate 300mm X 300mm X 3 mm, (ii) Earth Pit 6 ft depth filled up 3 with charcoal 10 kg & salt 25 kg in alternate layers up to 4 2 ft from bottom, (iii) Water funnel on Perforated Gl pipe of length 4.5 ft., (iv) Cast Iron top plate 12" x 12" (v)Drawing of copper-earth from earth to location with 25 mm x 3 mm copper strip for termination (all miscellaneous materials to be supplied by the contractor (Drg.No.S.C.Rly.Drg.No.5773) (Inspection by RITES)

20

20031

400620

... More
Supply and Installation of Multi Lamp Numeric Route Indicator (LED type Single/Double Digit) as per instructions of Engineer In charge Accepted Make/Brand : EFFTRONICS SYSTEMS PVT LTD or similar (Inspection by Consignee)

21

63802

1339842

... More
Supply and placement of RFID based Electronic Cable Marker with Specifications. 6 1)1.5m Depth Range, 2)10 Digit Hexadecimal ID Code, 3)Made of high impact polystyrene plastic casing sealed to IP65 4)Operating temperature : - 20 Deg C to + 60 Deg C. 5)Tensile stress at yield should be >19Mpa Markers shall be capable to integrate with GPS based marker locator and navigate to the location accurately (Inspection by Consignee)

400

2464

985600

... More
Installation of Self contained breathing apparatus & Fire Protective dress as per RDSO specification No. RDSO/SPN/218/2016 Ver 1.0-d2 or latest"

6

5533

33198

... More
Supply and Laying of RCC Pipes 100mm inside dia 2 M long carrying from the stock of central place at station to the work spot without causing any damage and placing them in the trench 8 duly clearing the ballast for track crossing / Down the culvert in the trench, gap between RCC Pipe and collar has to be closed using cement mortar as per the Drg.No.SK-19/10&20/10.All the materials viz. collars for the joints, cement mortar for closing gaps between collars and pipes are to be supplied by the contractor. (Inspection by Consignee)

200

210

42000

... More
Lime wash on walls/foundations at site as directed by site in-charge one coat with quick lime of approved quality.

3000

3

10830

... More
Replacement/Relocation of damaged/ dilapidated/warn out TLJ boxes, with new ones. This includes replacement of TLJ box, stump, pipes, termination of 2core cable and track lead wires, 10 fixing of TLJ box duly digging the size of pit is 50cm X 50cm X 50cm and keeping loose cable into the pit and closing the pit. TLJ boxes will be supplied by the railways as per the requirement Released dilapidated/ damaged TLJ boxes shall be transported and stacked at central location . This work has to be caried out under traffic conditions duly observing train movements.

400

588

235200

... More
Excavation of pit of 400 mm * 400 mm * 1500 mm at a given location and erecting rail 11 post of various lengths, plumbing and concerting with cement concrete in the ratio of 1:3:6 with 40 mm graded stone and river sand and curing the same ( rails and cements will be supplied by the railway)

20

300

6000

... More
Excavation of pit, casting concrete foundation as per Drg. No. RDSO/M/00011/R4 using 12 metallic templates, for erection of Colour light Signals upto 4 aspects (foundation bolts, cement, river sand, stone jelly of size 20/20mm dia and all other miscellaneous materials required for the work shall be supplied by the contractor).

35

13594

475790

... More
Drilling of holes of adquate diameter on the rails for installing transerve bonds in the track circuited area as per instruction of Engineer in charge

2000

47

94400

... More
Supply and erection of transverse and special bonds etc., as per drg.No.ETI/ OHE/G/05251 and instrctions of engineer charge. All materials shall be supplied by the contractor. (Inspection by Consignee)

600

596

358020

... More
painting and writing the particulars on signalling and telecom assets like implantations, Nos, DOI, DOH, and Earth Resistance values etc...(including paint) (Numbers = Per asset)

1000

50

50000

... More
Supply and installation wiring and commissioning of NI panel made out of MS sheet 16 16 guage of size 1200mm height x length 1200mm x depth 600mm with powder coated and also two relay frames fixed inside the panel for fixing of relays and wiring and all the internal wiring between signals, track circuits upto termination point with 200 wagos duly wired. NS 20000.00 Per

1

51200

51200

... More
Drawing of Indoor cable on a ladder , clamping and termination.

-

40000

40000

... More
Fabrication,Supply and errection of Powder coated Cable Supporting ladder made out of M.S flat of size 35mm width and fixing the same for 'K' Rack. The approximate size of the ladder is 2M x 0.4 M (all materials are to be arranged by the contractor.) (Inspection by Consignee)

40

782

31280

... More
Supply and fixing of FRP ladder type cable tray of size 300mm width, 80mm depth and 3mm thickness complete with all required connected accessories viz. Coupler plates, top covers etc as specified by site incharge. The cables are to be taken through the FRP ladder type cable tray without causing any damage as directed by Site Incharge. (Inspection by Consignee)

500

830

415000

... More
Supply and fixing of protection arrangement to the pedestals and meeting posts of 20 lifting barriers by providing MS Chain, 25mm ring, 10mm thickness of 1 meter length and fixing to the rail posts already available, drilling 12mm holes, fixing with 115mm x 12mm bolts and nuts and painting chain and rail posts. 21

2

2739

5478

... More
UL/Vds flow calculation

12

31729

380748

... More
Painting of Lifting barriers booms with alternate band of yellow and black and painting all accessories (Numbers = Per LC)

2

2250

4500

... More
Supply installation and fixing of PVC floor sheet of approved color of thickness 0.75mm (nominal) mat finish as per instructions of engineer in charge. (Inspection by Consignee)

400

222

89100

... More
Supply and installation of 19.5 inch Monitor with all connecting cables to monitor cctv cameras at location (Inspection by Consignee)

2

10653

21306.88

... More
1. Embedded Software Modification in FEP in Test room. 2.Software Modification in CMU to accept & transfer the relevant station Information in data packets through a Serial Port to a Client PC

1

174050

174050

... More
Supply, installation, testing and commissioning of 12 port 10/100 ethernet switch. Make: DIGISOL, HIKVISION or DLInK (Inspection by Consignee)

6

8444

50668.8

... More
Supply & Installation of Video Recording server with 240TB and Raid 6 Make : Axis/Genetec/Milestone/DELL/HP or latest (Inspection by Consignee) 30

2

3048333

6096666

... More
Overall commissioning of cameras and arrange network to headquarters

1

32480

32480

... More
Supply and fixing of 1 inch flexible PVC pipe on the walls as instructed by railway officials. All required items for fixing has to be arranged by contractor. (Min 5 screws / Mtr to be used). (Inspection by Consignee)

6

400

2400

... More
Supply and installation of RJ45 JACKS, Tags, C-Clamps & Spike box connecting cables. Make: MROTEK HOSTA-UG/DAX/HCL. (Inspection by Consignee) 33

6

1500

9000

... More
Testing & Commissioning of entire COA system

1

57820

57820

... More
Provision of Site Supervisors 36

48

41209

1978032

... More
Provision of Site Engineers

24

80154

1923696

... More
Installation of lightening arrestor Class A device on the top of the building. the devicesshall be installed at the height of about 3 mts from the roof of building using a G.I. mast. The device shall be connected to the earth pit using the copper tape 25mmx1.5mm or better the copper tape shall be run firmly along the side of the mast with the help of the spacers. It shall also be ensured that this down conductor shall not touch the building through out. The down conductor should be connected to the separate earth electrode as per Railway Board guidelines using exothermic welding. A counter shall be installed at an appropriate place to count the no of occurrences. All the accessories like spacers, welding material etc required for the installation shall be arranged by the contractor only. The installation of Lightning Arrestor should done by authorised representative of OEM.

4

33370

133480

... More
Perimeter Earthing: (a)Laying and commissioning of 6 x 50 mm galvanised steel tape in the trench depth of 600 mm connecting with MF earth pits throughout the building.

400

63

25200

... More
Perimeter Earthing: (b)Installation of copper tape 3 x 25 mm for bonding ring conductor inside the building along with required insulators and other required materials.

300

135

40500

... More
Supply & Termination of 6 quad cable Termination box of WAGO make. consists of part 40 nos:280-870 (24nos), 280-374(1nos),249-116(2nos),210-229/PW11-0000 (1nos) and Metallic box for outdoor use with locking facility-1 nos. Fixing of 12 pair CT box WAGO type Termination box and terminate six quad cable as per the instructions of Railway engineer at site on Teak wood plank of size 375x250x20mm thickness. (Inspection by Consignee)

50

1723

86170

... More
Installation of SDH equipment FMS racks etc., including DDF, LADDERS, RUNWAY, PATCH CORDS, 'P' MUX and their testing and commissioning..

1

11000

11000

... More
Installation, Testing and Commissioning of In- Cabinet Automatic Fire Suppression System 43

19

11255

213845

... More
Digging out the existing thermo shrinkable joint made for derivation joint.

20

600

12000

... More
Supply & installation of CT Boxes with wago terminals (50 pair) of WAGO make.consists of part nos:280-870 (100nos),280-374(1nos),249-116(2nos),210-229/PW11-0000 (1nos) and Metallic box for outdoor use with locking facility-1 nos. (Inspection by Consignee)

20

4165

83300

... More
Hiring of fully furnished Camp Office at site (of Size 2 BHK) for Railway S&T officials for monitoring/ supervision of work. The contractor will provide the storage safe for protection of 45 Important tender related document i.e. M.B./ Inspection certificates, drawings , T&P items etc .The rental cost includes electricity charges, water charges, cost of internet connection (Wifi) & cost of regular cleaning of camp office. The location of the camp office will be decided by the engineer in charge at any place/city/town near the section . Inspection: Consignee, Inspection Charges: None, Payment Terms: 100% after completion of each month cycle

24

15029

360700.32

... More
Transportation of light material /men with tools documents from central location to workspot and back

24

22500

540000

... More
Arranging unskilled workers with all tools for Non Interlocking working as per the instructions of engineer in charge. 48

1200

231

277200

... More
Integrity test for Automatic Fire Suppression System

6

168825

1012950

... More
Providing services of helping hand man power to carry out miscellaneous/sundry works 49 in the office/field between 08.00 hrs and 20.00 hrs of the day and accompanying Railway staff with all expenses of transportation, accomodation, food, consumables etc., with all ascents/descents, taxes, octroi, cess, fees, duties, with contractors tools

500

515

257500

... More
Supply and transportation of RCC Duct (Trunking and Capping) with 290mm width, 260mm height and 700mm Length as per DRG no. 5778A (Inspection by RITES)

5000

1785

8928550

... More
Supply, installation & commissioning of Modular Power supply Arrangement for VDU ( 51 42""-85"") and Industrial PC ( Embedded PC) with input and output redundancy arrangement and hot pluggable modules in set. One set Consists of :- 1. Input O-Ring diode Module with potential free-1 no contacts ( PFC) for two 110V DC sources from IPS and Single 110V DC Bus. Quantity : 1 No. 2. Isolated Inverters ( Master/Slave), Input 110 V DC, Output : 110/120 V AC 500 VA Quantity : 2 Nos. 3. Isolated DC-DC Converters, Input 110V DC, Out Put 24V DC/10A , Quantity : 2 nos. 4. 3U SS Rack with back Panel mother Board/front panel power connectors inverter auto changer over switch and all required over switch and all required protection circuits ( 3U height for main rack 132.5mm +/- 10% & 1U height for mounting 44.5mm +/-10%) Quantity; 1 No. ( Total 4 items ) Make : Gallant or Similar" (Inspection by RITES)

12

230100

2761200

... More
Supply and fixing of retro reflective tape on lifting barriers. (2 nos.)(Inspection by Consignee)

2

5387

10774

... More
Preparation of Station Working Rules, CRS papers etc as practice in Railways for yards/LC Gate/IBH including xerox

-

-

54

... More
Supply, Installation, Testing & Commissioning of Dual redundant arrangement of UFSBI electronics for exchange of vital relay state exchange pertaining to IB signalling, etc. The system comprises of following sub systems (a) Supply of electronics for UFSBI interface as per IRS 55 specification No.IRS-S-104/2012 ver.0 (latest amendment). Equipment should be equipped to work on both OFC and quad along with auto change over modem and Spares as below are also to be supplied for each pair. 1) Input Card DES/UFSBI/INPUT -1 Nos 2) CPU Card-1 Nos 3) Output Card DES/UFSBI/CPU -1 Nos 4)COMM CARD -1 Nos 5)DC-DC Converter- 1 Nos 6 )Reset Box- 1 Nos 7) MODEM- 1 Nos 8) 6U Mother board- 1 Nos 9) Auto Changeover Modem- 1 Nos (Inspection by RDSO)

1

1363300

1363300

... More
Installation, testing and commissioning of Pipes Fittings, Manifold & Cylinder stand Total Flooding Automatic Fire Suppression System (TFAFSS) 57

6

95667

574002

... More
Preparation of station specific Train arrival & departure logics for up to 15 Road station.

1

407100

407100

... More
Embedded Software Modification in Data logger to communicate with the above device and pass the information through the Data Logger Network.

1

41772

41772



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.