Public Works Department Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Public Works Department - PWD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date6 Sep 2024
Closing Date19 Sep 2024
Tender Amount₹ 1,17,08,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ for of six class room Building in Government Higher Secondary School at Thirumuttam
Tender Documents for of six class room Building in Government Higher Secondary School at Thirumuttam
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying and filling in basement with Garvel in layers of not more than 15cm.thick well rammed watered and consolidated etc., complete complying with standard specification.

245

-

-

... More
Brick work in In Cement Mortar 1:5 (One Cement Five Crushsed stone sand )using best quality II class Ground moulded chamber burnt bricks of size 9" x 4-3/8" x 2-3/4" for foundation and basement including curing, etc., complete complying with standard specifiction.

-

-

-

... More
For Foundation & Basement

64

-

-

... More
Brick work in In Cement Mortar 1:6 (One Cement Six Crushed stone sand ) using best quality II class Ground moulded chamber burnt bricks of size 9" x 4-3/8" x 2-3/4" for foundation and basement including curing, etc., complete complying with standard specifiction.

-

-

-

... More
For Super Structure in Ground Floor

57

-

-

... More
For Super Structure in First Floor

58

-

-

... More
For Super Structure in Second Floor

27

-

-

... More
Supplying and erecting Steel shuttering including necessary supports for Plane Surfaces in foundation and basement for reinforced cement concrete works such column footings, plinth beam, Grade beam, Stair Case steps, bed blocks etc., which requires only nominal strutting using stiffened with mild steel sheets of suitable size 90cm x60cm and BG 10 stiffened with mild steel angles of size mm of 25mm x 25mm x 3 mm for boardinglaid over silver oak joists of size 10cm x 6.50 cm spaced at about 60 cm centre to centre and supported by the casurina props of 10 cm to 13 cm dia paced at 75 cm centre to centre or at suitable intervals etc., complete complying with standard specifications. -The payment for centering shall be made only after the concrete laid. The retrieved materials should be taken back by the contractor-.

139.8

-

-

... More
Supplying and Erecting, Centering for sides and soffits including supports and strutting upto 3.29m height for plane surfaces as detailed below in all floors with all cross bracings using mild steel sheets of size 90cm X 60cm and BG 10 gauge stiffened with welded mild steel angles of size 25mm X 25mm X 3mm for boarding laid over silver oak joists of size 10cm X 6.50cm spaced at about 90cm centre to centre and supported by Casurina props of 10cm to 13cm dia spaced at not less than 75cm centre to centre at sutiable intervals etc., complete in all floors for complying with standard specifications. and as directed. The payment for centering shall be made only after the concrete laid. The retrieved materials should be taken back by the contractor.-

-

-

-

... More
Plane surfaces such as RCC floor slab, roof slab, rectangular, square, Tee or Ell beam, lintels, bed blocks staircase waist slab, landing slab, landing beams, portico beams, portico slab etc.,

742

-

-

... More
Plane surface such as RCC square or rectangular columns, top and bottom slab of sunshade, boxing sill slabs, etc.,

353.5

-

-

... More
Providing and laying in position, standardised concrete Mix M-2o Grade in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering etc., complete complying with standard specification and as directed by the departmental officers

-

-

-

... More
For Foundation & Basement

56.5

-

-

... More
For Super Structure in Ground Floor

36

-

-

... More
For Super Structure in First Floor

55

-

-

... More
For Super Structure in Second Floor

3.5

-

-

... More
Supplying, fabricating and placing in position of steel reinforcement using mild steel/ribbed tor steel bars for all RCC works as per the design given including cost of steel and binding wire in all floors complying with standard specifications.

191

-

-

... More
Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.

19.59

-

-

... More
Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers

221.38

-

-

... More
Cement concrete 1:5:10 (One cement, five Crushed stone sand and ten aggregate)using 40mm gauge hard broken granite stone jelly for flooring base including consolidating as per standard specification, curing and rendering the top surface rough to received floor finish etc., complete complying with standard specifications.

30.36

-

-

... More
Brick partition walls of 11.50cm thickness using best quality II class Ground moulded chamber burnt bricks of size 9" x 4-3/8" x 2-3/4" in Cement Mortar 1:3 (One Cement and Three crushed stone Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately)

-

-

-

... More
In Ground Floor 11.50 cm thick

7.02

-

-

... More
In First Floor 11.50 cm thick

7.02

-

-

... More
Supplying and fixing fine polished cuddapah slab of following thickness for cup-board arrangements including laying to correct alignment with necessary cement mortar and black powder etc, complete complying with standard specification and as direct.40 mm thick

12.96

-

-

... More
Supplying and fixing in position best approved ISI quality PVC Rainwater Downfall pipes of 110mm diameter having working pressure of 4kg/cm2 including cost of PVC pipe, with necessary shoes, bends, nails, teakwood plugs, screws etc, and fixing of cast iron gratings of required dia metre and special clamps at junction of parapet and the RCC roof slab including finshing neatly etc., complete. The PVC pipe shall be fixed with teakwood plugs by means of "U" Clamps using brass screws. Special types of "U" clamp at the centre of the pipeline shall be fixed in addition to those for more than 3 metre pipe length complying with standard specifications.

63.2

-

-

... More
Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three crushed stone sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)

86.72

-

-

... More
Flooring with fully Rajesthan kotta stone of size 18 to 20 mm thickness(Unpolished) laid over in cement mortar 1:3 (One cement and three Crushed stone sand) 20 mm thick (over the existing bed of 100 mm thick cement concrete 1:5:10) and pointing the joints to full depth of cuddapah slabs with cement Mortar 1:3 (One cement and three Crushed stone sand) mixed with block oxide and the top surface rubbed smooth etc., complete complying with standard specifications.

428

-

-

... More
Manufacturing, supplying and fixing in position of STEEL WINDOWS with the following specifications. Outer frames of windows made of ‘Z’ section F7D of size 33 x 25 x 3mm at 1.419 Kg / m and mullion ‘J’ Section (F4B) of size 46 x 25 x 3mm at 2.28 Kg / m and shutter section of made of F7D of 33 x 25 x 3mm at 1.419 Kg / m as specified in IS 7452 / 1990. Each openable shutter should not exceed a width of 600mm to enable separate operations and easy maintenance. The panel of the shutters to be covered with 18 gauge cold rolled sheet of superior quality and welded intact with shutter frames. Horizontal stiffeners using 18 x 5mm MS Flat at 0.70 Kg / m at 3 Nos. for each shutter and additional diagonal stiffeners of the same MS Flats at all the four corners of each shutters to the suitable length welded to the shutters, for holding the CR Sheets in position firmly.

-

-

-

... More
Four Leaves

32.76

-

-

... More
Manufacturing supplying and fixing of Steel Door with following specification ms angle of size 40x40x6mm at 3.5 kg / metre used for outer frame and ms angle of size 35x35x5 at 2.6 kg / m for the shutter frame stiffness with 32x6mm at 1.5kg/m ms flat is provided as the lock rail of the door and welded intact on both ends to the shutter frame 18 GCR sheets of best quality is laid as panel in the shutter frames 18x5mm at 0.70 kg/m ms flat or provided diagonally on the rate side of the shutter 2Nos of hinges incase of single leaf and 4Nos hinges incase of single leaf shutter is provided 6Nos hold fast 200mm length at end are welded to outer frame of tne door tower bolts 2Nos one at the top and another at the bottom are provided one aldrop is provided incase of single leaf door at rock rail section in the inner side of the rock rail section of the door one rotating rocking arrangements for the inner side of the door and additional provisions for locking arrangements

-

-

-

... More
Single leaf

2.1

-

-

... More
Double leaf

15.12

-

-

... More
Fabricating, supplying and fixing of steel Emergency exitdoor cum, emergency window with the following specification. M.S. angle in size 40x40x6mm are used for the outer frames and M.S. angle of sie 35x35x5mm for the shutter frame, stiffners with 32x6mm M.S. flats provided at required intervals in the shutter frames 18 guage CR sheet is laid as panel and welded instant for 1/3 bottom portion of the shutter, M.S. flat 18x5mm is welded over the 32x6mm M.S flat sandwitching the CR sheet in between additional stiffner with 18x5mm M.S. flat is provided diagonally at the rear-side of the shutter. The balance 2/3 portion at top is provided with grill at an average weight of 15kg/m2 and the top portion of operation emergency window is to be made of 25x25x3mm M.S. angle welded intact with CR sheet and 25x3mm M.S. flat at diagonally at the near side of the window at required interwals 6 Nos. of hinges to be provided,6 Nos of holdfast 100mm in length made of angle section spliced at the ends are welded to the outer frame of the door. Tower bolts 2 Nos. one at top and the other at the bottom are to be provided one aldrop is provided at an appropriate place in the door 2 Nos. of 'D' type handle for emergency window and 2 Nos of handle for door is to be provided at appropriate places. A tie bar is provided at the bottom of the outer frame to prevent twisting of frame during transportation of fixing. All members are given one coat of red oxide primer as directed by the departmental officers. The rate includes cost of materials, labour transportation to side of works, loading, unloading and all other incidental charges etc., complete.Supplying and fixing of Mild steel window Double Leaves cum emergency door for emrgency exist with top window position covered with MS sheet using section of 32x29x5mm thick of door frame. The shutter shall be made out of FX6 section of size 29x29x5mm with necessary stiffners shall be 25x25x5mm outer frame covered with MS sheet shutter will be fixed to the frame of means hinges with necessary towerbolt, aldrops etc., bottom 1/3rd of door covered with Hinges of MS sheet shall be welded upto sill level of outer frame. The emergency door will given one coat of zinc ornamental yellow primer etc., complete complying with standard specification. Four leaves

15.12

-

-

... More
Painting two coats over new iron works such as steel doors, windows, ventilators, window bar balustrades etc., with best approved first quality synthetic enamel paint of approved colour over the existing red oxide priming coat in all floors. The rate is inclusive of all materials, brushes and scaffolding charges etc., complete complying with standard specification -Paint should be got approved by the Executive Engineer before use on work-.

285.56

-

-

... More
Supplying and fixing in position steel balustrade using 20mm size square bars at 15cm centre to centre and two balusters in single step centrally located and top shall be welded to 40mm X 6mm mild steel flat to fix the handrail having a groove 40 x 6mm and bottom fixed in the step concrete fixing M.S. Flats of size 50mm X 6mm to be provided at the centre of the balustrade connecting all the square bars to the entire length of the balustrade and the square bars well anchord in the floor / step concrete through fish tail splay at bottom including painting the steel member of the balustrade with one coat of red oxide primer etc., complete complying with standard specifications.

25.07

-

-

... More
Supplying and fixing in position 40 mm dia best approved quality “B” class G.I. Pipe for staircase handrails welded rigidly with balustrades including cutting the G.I. Pipe to required length bending at the flight turning welding neatly the G.I. Pipe at joints etc., completed as directed by the departmental officers.

36.16

-

-

... More
Plastering with cement mortar 1:5 (One cement and five P-sand) 12mm thick in all floors complying with standard specifications and as directed by the departmental officers.

1578.12

-

-

... More
Special ceiling plastering and finishing the exposed surfaces of RCC work such as RCC slabs, sunshades, facia, canopy slab, staircase. Waist slab landing slab etc., with cement mortar 1:3 (One cement and three P-sand) 10mm thick including hacking and providing necessary cement mortar nosing, beading etc., wherever necessary and as directed with the same cement mortar etc., complete complying with standard specifications as directed by the departmental officers.

435.92

-

-

... More
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.

1393.92

-

-

... More
Painting the wall two coats with approved weather proof Exterior Emulsion paint over one primer coat of over cement plastered wall surface ect., complete complying with standard specification.

930.28

-

-

... More
Providing Pre construction Anti termite treatment for the building including all chemicals as per standard specifications. Labour charges for preparing the areas for treatment spraying chemicals and other incidential charges etc., complete. The rate shall be inclusive of giving anti-termite treatment to the building for the following four stages including breaking the termite mounds making holes with crow bars at an interval of 12"to a depth of 8" in the periphery of building and pouring chemicals etc., complete as per ISI 6313-1981 and. The antitermite chemicals used should have 0.5% concentration with 3L solution for the entire operation etc. as directed by the Engineer incharge and including cost of chemicals labour transportion etc, Stage-1: Spraying anti-termite chemical solution for the foundation before laying concrete, in bottom and sides of foundation. Stage-2: Spraying anti-termite chemical solution to the grade beam level, spraying has to be done for the grade beam, brick masonry contact with the back fill earth. Stage-3: Spraying anti-termite chemical solution on the sand for the flooring before laying the flooring concrete. Stage-4: Spraying anti-termite chemical solution alround building outside by making holes through bar before laying plinth protection and the holes to be closed after the treatment

249

-

-

... More
Supplying and Fixing M.S grill to opening corridor sides, ladder Entrance gate and Name board angles etc., Using necessary M.S flat for inner members and outer members which should be fixed to window members frames as directed by departmental officers inclusive of cost of providing one coat of best quality red oxide primer. -The design of M.S. grill should be got approved from departmental officers before use on works.-

1809.6

-

-

... More
Supplying and fixing colour galvanum sheet roof of 0.47mm thickand steel tubular box section of 100x50x3mm of 1meter interval including priming coat fixing in position with all necessary accessories complete complying with standard specification and as directed by the departmental officers.

34.03

-

-

... More
Supplying and applying of Two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothly with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc., complete complying with standard specifications and as directed by the departmental officers. (The rates are inclusive of hire charges for grinding machine with wheel, cost of sand paper (water proof abrasive sheet) cost of putty blade, labour charges for grinding the joints and sand papering, two coats of putty, scrapping the putty area to level the surface smooth, etc., complete). The putty should be got approved by the Executive Engineer before use on work

407.6

-

-

... More
Providing Blackboard in two layers with first layer in cement mortar 1:5 (one cement and five crushed stone sand)20mm thick and the second layer in Combination mortar 1:1:6(one cement one lime and six crushed stone sand) 20mm thick and providing band all round the block board in c.m 1:5 (one cement and five crushed stone sand) for 20mm thick and 50mm width including cost of one coat of block oxide paint of approved quality complying with standard specification.

31.2

-

-

... More
Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.

9.42

-

-

... More
Supplying and fixing of G.I pipe of heavy type G.I sheet / PPGI sheet roofing rafter and purlin and vertical posts including labour for cutting, threading and fixing in position of pipes. The pipes are to be painted with two coats of good variety and approved quality of synthetic enamel over a priming cost of red oxide etc., complete as directed by the Detpl.,Officers during exeuction of work.

-

-

-

... More
40mm thick

47.7

-

-

... More
Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS 15683 with pressure gauge, discharge hose & control nozzie, wall mounting bracket, safety clip etc., ncluding conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition whererver found necessary etc complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT/ SAFETY FIRST or EQUIVALENT. (rate as per SSD)

2

-

-

... More
Add GST 18%

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.