Military Engineer Services Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date30 Sep 2024
Closing Date28 Oct 2024
Tender Amount₹ 35,00,000
Costs
EMD
₹ 70,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_677417_1Bid Award Id
ViewTender No
8773Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
one 3 pin socket outlet 5 amps on the same board controlled by one switch.
8
-
-
one 3 pin socket outlet 5 amps on independent board controlled by one switch.
14
-
-
one light point controlled by two switch of 2 Way
2
-
-
one bell/buzzer point controlled by one bell push
6
-
-
As per above items No. 1 for one socket outlet three pin 15 amps control by one switch independent board with cable 2.5 sqmm size complete all as specified and directed.
8
-
-
M&L for point wiring of size 1.5 sqmm (two run) with PVC insulated unsheathed multistranded copper conductor cable of 1100V grade drawn through non metallic rigid Existing PVC conduit , in wall/floor and fixed on ceiling/roof etc, incl provn of 1.5 sqmm PVC insulated copper earth conductor cable for earth continuity and connecting to common earth dolly including taking down old copper/aluminium point wiring light, fan, socket or power complete with fittings such as switches, ceiling roses, regulators sockets etc and making good disturbed surfaces of walls, floors to match with the existing surface complete all as specified and directed for the following;-
-
-
-
one light point controlled by one switch
150
-
-
one fan point controlled by one switch
20
-
-
one bell/buzzer point controlled by one bell push
20
-
-
one 3 pin socket outlet 5 amps on the same board controlled by one switch.
45
-
-
one 3 pin socket outlet 5 amps on independent board controlled by one switch.
8
-
-
one light point controlled by two switch of 2 Way
3
-
-
As per above items No 3 for one socket outlet three pin 15 amps control by one switch independent board with cable 2.5 sqmm size complete all as specified and directed.
10
-
-
M&L for point wiring of size 1.5 sqmm (two run) with PVC insulated unsheathed multistranded copper conductor cable of 1100V grade drawn through non metallic rigid surface PVC conduit , in wall/floor and fixed on ceiling/roof etc, , incl provn of 1.5 sqmm PVC insulated copper earth conductor cable for earth continuity and connecting to common earth dolly including taking down old copper/aluminium point wiring light, fan, socket or power complete with fittings such as switches, ceiling roses, regulators sockets etc and making good disturbed surfaces of walls, floors to match with the existing surface complete all as specified and directed for the following;-
-
-
-
one light point controlled by one switch
250
-
-
one fan point controlled by one switch
20
-
-
one bell/buzzer point controlled by one bell push
15
-
-
one 3 pin socket outlet 5 amps on the same board controlled by one switch.
80
-
-
one 3 pin socket outlet 5 amps on independent board controlled by one switch.
60
-
-
one light point controlled by two switch of 2 Way
6
-
-
As per above items No 5 for one socket outlet three pin 15 amps control by one switch independent board with cable 2.5 sqmm size
20
-
-
M&L for point wiring of size 1.5 sqmm (two run) with PVC insulated unsheathed multistranded copper conductor cable of 1100V grade drawn through new non metallic rigid casing caping in wall/floor and fixed on ceiling/roof etc, incl provn of 1.5 sqmm PVC insulated copper earth conductor cable for earth continuity and connecting to common earth dolly including taking down old copper/aluminium point wiring light, fan, socket or power complete with fittings such as switches, ceiling roses,regulators sockets etc and making good disturbed surfaces of walls, floors to match with the existing surface complete all as specified and directed for the following;-
-
-
-
One light point controlled by one switch
250
-
-
One fan point controlled by one switch
80
-
-
One 3 pin socket outlet 5 amps on the same board controlled by one switch.
60
-
-
One 3 pin socket outlet 5 amps on independent board controlled by one switch.
60
-
-
One bell/buzzer point controlled by one bell push
15
-
-
As per above items No 7 for one socket outlet three pin 15 amps control by one switch independent board with cable 2.5 sqmm size (two run) & 1.5sqmm (one run) complete all as specified and directed.
30
-
-
S& F for modular metal flush box 2 module complete all as specified and directed.
125
-
-
S& F for modular metal flush box 4 module complete all as specified and directed.
95
-
-
S& F for modular metal flush box 6 module complete all as specified and directed.
80
-
-
S& F for modular cover plate with frame 2 module complete all as specified and directed.
125
-
-
S& F for modular cover plate with frame 4 module complete all as specified and directed.
95
-
-
S& F for modular cover plate with frame 6 module complete all as specified and directed.
80
-
-
S&F modular switches suitable for type AC 240V, 6 amps 1 module complete all as specified and directed.
1255
-
-
S&F modular sockets suitable for type AC 240V, 6 amps 2 module complete all as specified and directed.
335
-
-
S&F modular switches two way suitable for type AC 240V, 6 amps 1 module complete all as specified and directed.
11
-
-
S&F modular switches suitable for type AC 240V, 16 amps 1 module complete all as specified and directed.
68
-
-
S&F modular power sockets suitable for type AC 240V, 16 amps 2 module complete all as specified and directed.
68
-
-
S&F modular fan regulator suitable for type AC 240V, 2 module complete all as specified and directed.
50
-
-
S&F modular bell switch suitable for type AC 240V, 16 amps complete all as specified and directed by Engr-in-Charge
56
-
-
S&F call bell of multi music type A/C 230 volts complete all as specified and directed.
56
-
-
S&F ceiling rose , polycarbonate, isolated body with 2 to 3 terminals complete all as specified and directed.
510
-
-
S&F lamp holder insulated body with back plate for batten fittings/angle holder complete all as specified and as directed.
120
-
-
S&F of LED bulb 9 w high suitable for lamp holder including taking down unserviceable fittings and making good disturbed surfaces of walls, floors to match with the existing surface complete all as specified and as directed. Make : Havells/CG/ Philips /Wipro
280
-
-
S & F 20 Watts LED COOL LIGHT fitting, surface mounting general purpose LED Battens in Extruded Aluminium housing with wide range of wattages to suite variety of application areas, including taking down unserviceable fittings and making good disturbed surfaces of walls, floors to match with the existing surface complete all as specified and as directed. Make : Havells Cat No. LUMILINEPLUSNEOBS20WLED865SPCSSIND or equivalent in Philips/Bajaj.
390
-
-
S & F 10 Watts LED COOL LIGHT fitting, surface mounting general purpose LED Battens in Extruded Aluminium housing with wide range of wattages to suite variety of application areas, including taking down unserviceable fittings and making good disturbed surfaces of walls, floors to match with the existing surface complete all as specified and as directed.
Make : Havells Cat No. LUMILINEPLUSBS10WLED865SPCSSIND or equivalent in Philips/Bajaj.
100
-
-
S & F 36 Watts 2x2 ceiling COOL LIGHT a versatile 2X2 recess mounted luminaries which suits various ceiling types with option to add mounting kits for POP ceiling & suspension clamp for pendant mounting from true ceiling, including taking down unserviceable fittings and making good disturbed surfaces of walls, floors to match with the existing surface complete all as specified and as directed. Make Havells Cat No. VENUSNEO2X2PLR36WLED865G2 or equivalent in Philips/Bajaj.
20
-
-
S&F in repairs of switch piano flush type 5 amps single pole one way including taking down unserviceable complete all as specified and as directed.
450
-
-
S&F in repairs of switch piano flush type 5 amps single pole two way switch including taking down unserviceable complete all as specified and as directed.
20
-
-
S&F in repairs of modular switches suitable for type AC 240V, 6 amps, 1module including taking down unserviceable complete all as specified and as directed.
320
-
-
S&F in repairs of modular sockets suitable for type AC 240V, 6 amps, 2 module including taking down unserviceable complete all as specified and as directed.
200
-
-
S&F in repairs of socket outlet 2 in 1, 3pin 5 amps 230 volts including taking down unserviceable complete all as specified and as directed.
150
-
-
S&F in repairs of modular switches suitable for type AC 240V, 16 Amps, 1 module including taking down unserviceable complete all as specified and as directed.
80
-
-
S&F in repairs of modular power sockets suitable for type AC 240V, 16 Amps, 2 module including taking down unserviceable complete all as specified and as directed.
80
-
-
S&F in repairs of switch piano flush type 15 amps single pole one way including taking down unserviceable switches complete all as specified and as directed.
60
-
-
S&F in repairs of socket outlet 3 pin, 15 Amp, flush type including taking down unserviceable complete all as specified and directed.
60
-
-
S&F in repairs of bell push 5 amps 230 volts flush type including taking down unserviceable complete all as specified and directed.
20
-
-
S&F in repairs of Electronic fan regulator dimmer type,450w , 250 volt including taking down unserviceable complete all as specified and directed.
200
-
-
S&F sub main wiring complete with two runs of 4 sqmm PVC insulated unsheathed single core multistrand copper conductor cable of 1100 volts grade drawn through new non metallic rigid PVC conduit pipe concealed in wall along with accessories fixed on walls/floors/ceiling with one run of 4 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor including taking down old sub main wiring after proper disconnection of electric supply and making good disturbed surface to match with the existing surface complete all as specified and as directed. Note:- Two runs of PVC insulated cable 4 sqmm + one run 4 sqmm of earth wire and one run of conduit including accessories shall be measured as one length.
80
-
-
S&F sub main wiring complete with two runs of 4 sqmm PVC insulated unsheathed single core multistrand copper conductor cable of 1100 volts grade drawn through new non metallic rigid PVC casing & caping on wall along with accessories fixed on walls/floors/ceiling with one run of 4 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor including taking down old sub main wiring after proper disconnection of electric supply and making good disturbed surface to match with the existing surface complete all as specified and as directed. Note:- Two runs of PVC insulated cable 4 sqmm + one run 4 sqmm of earth wire and one run of conduit including accessories shall be measured as one length.
460
-
-
S&F sub main wiring complete with two runs of 4 sqmm PVC insulated unsheathed single core multistrand copper conductor cable of 1100 volts grade drawn through existing PVC conduit on wall along with accessories fixed on walls/floors/ceiling with one run of 4 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor including taking down old sub main wiring after proper disconnection of electric supply and making good disturbed surface to match with the existing surface complete all as specified and as directed. Note:- Two runs of PVC insulated cable 4 sqmm + one run 4 sqmm of earth wire and one run of conduit including accessories shall be measured as one length.
450
-
-
Taking down AC box any type and any size complete after taking proper disconnecting of electric supply properly and making good surface complete all as specified and directed
44
-
-
S&F MCB Power unit with 4 module steel box consisting of 3 pin 24 Amps socket with Plug top and MCB SP 25 Amps, suitable for operation of AC & Geysers etc., complete all as specified and as directed.
(Make :- Havells/Legrand/Anchor)
44
-
-
M&L for painting of existing main DB Box or Meter Box by preparing of surfaces and applying two coats of synthetic enamel paint and writing of existing details such as Qtr No. etc complete all as specified and as directed.
30
-
-
S&F MCB distribution board made of CRCA sheet, powder coated paint conforming of IS 13032, double door fixed in switch boards/wall at various places of capacity 240volt 12 way MCB DB, SPN with 200 Amp rated bus bar shall conform to IP 38 protection incl taking down old MCB DB any type and any size complete after properly disconnecting electric supply properly and making good surface complete all as specified and directed.
10
-
-
S&F MCB distribution board made of CRCA sheet, powder coated paint conforming of IS 13032, double door fixed in switch boards/wall at various places of capacity 240volt 8 way MCB DB, SPN with 200 Amp rated bus bar shall conform to IP 38 protection incl taking down old MCB DB any type and any size complete after properly disconnecting electric supply properly and making good surface complete all as specified and directed.
16
-
-
S&F MCB distribution board made of CRCA sheet, powder coated paint conforming of IS 13032, double door fixed in switch boards/wall at various places of capacity 415 volt 8 way MCB DB, TPN with 200 Amp rated bus bar shall conform to IP 38 protection incl taking down old MCB DB any type and any size complete after properly disconnecting electric supply properly and making good surface complete all as specified and directed.
6
-
-
S&F MCB distribution board made of CRCA sheet, powder coated paint conforming of IS 13032, double door fixed in switch boards/wall at various places of capacity 415 volt 6 way MCB DB, TPN with 200 Amp rated bus bar shall conform to IP 38 protection incl taking down old MCB DB any type and any size complete after properly disconnecting electric supply properly and making good surface complete all as specified and directed.
6
-
-
S&F MCB TPN 100 Amps 415 Volts incl taking down old MCB any type and any size complete after properly disconnecting electric supply properly and making good surface complete all as specified and directed.
12
-
-
S&F MCB of SPN 63 Amps 240 Volts incl taking down old MCB any type and any size complete after properly disconnecting electric supply properly and making good surface complete all as specified and directed.
26
-
-
S&F MCB of Single pole of rating 6 to 32 Amps 240 Volts incl taking down old MCB of any type and any size complete after properly disconnecting electric supply properly and making good surface complete all as specified and directed.
200
-
-
Earthing complete with galvanised steel earth plate electrode 60cm x 60 cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25m deep below ground level with top edge of plate not less than 1.5 below ground level connected to GI 4 mm earth wire by means of bolts, nuts check nuts washers made of galvanised iron or steel earth wire protected by GI pipe 15 mm bore light grade connected up to switch board incl 20mm bore GI water pipe with funnel and wire mesh all as shown in electrical plate No.3 of SSR Part I including dearth chamber of PCC 1:2:4 type B1 using 20mm grade aggregate with RCC cover slab 1:2:4 type B1, 40mm thick with 15mm dia MS bar 100mm C/C both ways and 6 MM dia MS hooks complete all as specified including testing on completion.
11
-
-
Evaluation Notes How It Works ?