Military Engineer Services Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Military Engineer Services - MES Tender
Civil And Construction
Eprocure
Opening Date10 Jul 2024
Closing Date4 Sep 2024
Tender Amount₹ 29,00,000
Costs
EMD
₹ 58,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_665230_1Bid Award Id
ViewTender No
8428/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
S & F End piece of size 60X230mm for closing of cable tray at end part & including appropriate fastening materials complete all as specified & as directed. Model No WDKHE60230CW(6162886) of make OBO or equivalent of Legrand or any equivalent E-in-C Branch approved make.
10
-
-
S & F the following mounting accessories :
Internal corner cover of dimension 230 x 60 Model No WDK HI60230 CW (6160395) of make OBO or equivalent of Legrand or any equivalent E-in-C Branch approved make.
10
-
-
S & F the following mounting accessories :
External corner cover of dimension 230 x 60 Model No WDK HA60230 CW (6160980) of make OBO or equivalent of Legrand or any equivalent E-in-C Branch approved make.
10
-
-
S & F the following mounting accessories :
T & Intersection cover of dimension 230 x 60 Model No WDK HK-60230 CW (6162290) of make OBO or equivalent of Legrand or any equivalent E-in-C Branch approved make.
10
-
-
S & F the following mounting accessories :
Flat angle cover of dimension 230 x 60 with Model No WDK HF-60230 CW (6161596) of make OBO or equivalent of Legrand or any equivalent E-in-C Branch approved make.
10
-
-
S & F the following mounting accessories :
Cover clip of dimension 230 x 60 for fixing of tray Model No 2370230 (6023584) of make OBO or equivalent of Legrand or any equivalent E-in-C Branch approved make.
20
-
-
S& F FRLS PVC insulated single core, multistranded copper conductor cable, 2.5 Sqmm, 1100 volts grade. Make : Finolex/Polycab/Havells.
100
-
-
S& F FRLS PVC insulated single core, multistranded copper conductor cable,4.00 Sqmm, 1100 volts grade. Make : Finolex/Polycab/Havells.
200
-
-
S& F FRLS PVC insulated single core, multistranded copper conductor cable,6.00 Sqmm, 1100 volts grade. Make : Finolex/Polycab/Havells.
200
-
-
S& F Cat 6 Cable, 4 Pair, unshielded twisted pair (UTP) industrial cable for LAN network. Make : Finolex/Polycab/Havells.
250
-
-
S & F non- metallic PVC rigid conduit (medium grade) 20 mm dia with all fittings and accessories ISI marked complete.
300
-
-
S & F non- metallic PVC rigid conduit (medium grade) 25 mm dia with all fittings and accessories ISI marked complete.
250
-
-
Labour only for removing of existing electrical, data, LAN Network cable along with connection and conduit/Cashing-capping of any size/type and Refixing the same wire/data cable in Cable trunk with fixing accessories.Note:- Extra wire/PVC conduit of any type if used at site is measured and paid separately under relevant items.
105
-
-
IMPORTANT NOTES : 1) Design / drawing / BOM of the complete Cable Tray system showing the layout & dimensions is to be obtained from OEM strictly keeping in view the actual ground/site requirement & the same is to be got approved from GE before placing final order to the manufacturer.
2) Anything missed out in the technical specifications but technically required for efficient working of the system is deemed to be included in the quoted rates.
3) The contractor is required to visit the site prior to quoting of the subject item/work so as to ascertain the actual ground requirement. Any further query at a later date shall not be entertained & responsibility of the same shall rest with the contractor.
4) The entire work of the Cable Tray system is to be got done from the OEM or their auth Sister Concern/Channel Partners only.
-
-
-
Supply , installation, Commissioning and Testing of Air management system for common toilet block (gent's toilet and ladies toilet) comprising of the following items :-
2
-
-
(a) 1. 200 MM Axial Flow Fan - 3Nos to be fixed in UPVC duct after cutting the UPVC Pipe of 200mm Dia with complete electrical wiring passing through pvc conduit clamping on wall/suface/ceiling, system with required protection like-louvers,metal net, etc to prevent the insertion of birds, dust inside the duct.
2. 200MM Dia UPVC Duct of suitable length as per site requirement through out the toilet with necessary fixing accessories like-bends, Tee, couplers,lock nuts,saddles,pipe hooks,flexible reinforcement hoses, fixing clamp for suitable length, Air intake and outflow system height of 2 Mtr or higher side from the ground level and 4.5 Mtrs or higher side as per site requirement height above the ground level, vertical and horizontal suitable length
3. Centrifugal type Airflow Blower power - 2 HP (3 phase/415V/50HZ) Static pressure - 150MM WC Air flow - 1850 M3/Hr Mounting - Flange/foot mounted. It should be mounted on 3 Mtr or higher side as per site requirement above the ground level.Note: the rate quoted by contractor is deemed to be inclusive of necessary PCC foundation work for mounting control panel and air flow blower.
4. The ducting systems permanently supported with angle iron Frame/Spacer clamps / suitable clamps and fixers etc
5. Control Panel of size 900X900X60 mm suitable for 2 HP blower panel
Incomer with suitable Bus Bar arrangements a. 32A FP MCB - 1 No
(b) Outgoing
16-32 A TP MCB with DOL Starter - 1 Set 6-32 A DP MCB With 2A Single Phase starter - 4Nos
With necessary On/Off Push button - 5 Sets
1 Set of multi function Meter with control wirings
1 Set of RYB Indication Lamps
The above Panel Manufacturing with CPRI Approved manufacturer
5 Sets of necessary cable of suitable size and length for connection from control panel to motors
-
-
-
Supplying, Laying, Commissioning & testing of LT underground cable, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 4 core 10 Sqmm, including cable lugs, clamping of cable whereas the cable passes along the wall/ poles, connection/termination complete all as specified and directed by Engr-in-Charge. Make : Havells/Finolex/Gloster/polycab. Note :- Wherever the cables are to be laid/fixed on walls/ceiling/other surfaces the cost of clamping using appropriate size/type of MS clamps,nuts both etc is deemed to be included in the unit quoted rates.
120
-
-
IMPROTANT NOTE FOR SER ITEM NO 16
(1) The complete works of the Air management system is to be got done from the OEM of their authorized sister concern/channel partner only.
(2) Design/Drawing/BOM/ Technical specifications of the complete Air management system showing the layout including dimensions is to be obtained from OEM strictly keeping in view the actual ground requirements & the same is to be got approved from Engr-in-Charge & GE before placing final order to the OEM. (3) Any items missed out in the technical specification , but technically required for efficient working of the system is deemed to be included in the unit quote rates.
(4) The contractor /Firm is required to visit the site prior to quoting of the subject items/work so as to ascertain the actual ground requirements. Any further query at a later date shall not be entertained & resposibility of the same shall rest on the contractor/firm.
(5) Comparative analysis in respect of the items wherever techno-commercially equivlent w.r.t the given Cat/Part/Model ref concerned is to be submitted to the Engr-in-Charge & GE for approval.
(6) The cost of cutting the existing Window/ventilator/wall for passing the UPVC Duct and electrical wiring through pvc conduit and making good the disturbed surfaces and (floors,ventilator,window,Walls, ceiling, Pavement etc) is deemed to be included in the unit quoted rate of relevant items.
(7) On testing if the desired Air air flow exhaust is not found according to as per desired Standards it is to be redone to the entire satisfaction of Engr-in-Charge at no extra cost to the Dept after completion of work contractor should submit a detailed Report of Air flow test result from OEM and same is to be certified from Engr-in-Charge & GE.
(8) Repair/ Preventive maintenance of the complete Air management system is to be got doen from the OEM /Sister Concern/Channel partner only by the contractor for the entire defect liability period i.e two years from the certificate date of competion & the cost of the same is deemed to be included in the unit quote rates.
(9) If any damage to any electical/communication cables or any pipe lines or any other installations occurs during execution of the work then the same shall be made good by the contractor to the entire satisfaction of the concerned & the cost of the same is deemed to be included in the unit quoted rates.
(10) Testing at an interval of 6 months of the entire Air management system is to be got done drom the OEM/Sister Concern/Channel Partner only by the contractor & report submitted accordingly to the Engr-in-Charge of the entire defect liability period & and the cost of the same is deemed to be included in the unit quote rates.
(11) Purchase Voucher & Manufacturers test certificates to be submitted in original to the Engr-in-Charge.
-
-
-
Supply , installation, Commissioning and Testing of Maintenance Free Earhting system comprising of the following :-
Copper Bonded Steel Earth Rod of 3 meter length and 14.2 mm diameter. Auger a hole of diameter 3 inch and 9 feet depth in the soil, placing the Earth rods in to theaugured hole, hammering the rods to 1 feet depth, removing excavated material. Make ERICO Cat Part No:CODE615800 or techno-commercially equivalent of DEHN/ SEIMENCE complete all as specified and as directed by Engr-in-Charge. Brief features/ specifications of CBSE Rod is as follows:
(a) The outer surface must be molecularly bonded with uniform layer of 250 micron Copper, 99.9% pure electrolytic coating.
(b) Nickel interface must be provided between the copper and steel to avoid the galvanic corrosion
(c) Must be capable of withstanding fusing current of 20 KA @ 1 Sec.
(d) Earth rod must be in compliance with IEC 62305- 2, NBC 2010 and IEEE 80. Rod should be tested as per IEC-62561-2 standard.
(e) Tensile strength greater than 80000 PSI on 12 mm.
(f) High resistance to corrosion.
(g)Material category numbr shall be listed in UL listed , Manufacturer Make Part No and UL mark should be printed in each rod.
6
-
-
Supply , installation, Commissioning and Testing of Maintenance Free Earhting system comprising of the following :-
Ground Enhancement Material (GEM) , Per Bag -11.33 Kgs ,Conforming to IEC 62561-7 Standard, , Premixing the GEM into slurry form using water( not more than5 L to 6 L per bag), Pouring the GEM mixture in the augured hole and filling. Make ERICO Cat Part No: GEM 25A- 25-1lb or techno-commercially equivalent of DEHN/ SEIMENCE complete all as specified and as directed by Engr-in-Charge. Brief features/ specifications of the follows :
(a) Must be carbon based superior conductive material. (b) Resistivity must be less than 2 Ω-cm. (c) Must not cause corrosion to copper when in contact. (d)Must notexpand or experience any shrinkageonce set. (e)Must not depend on the continuous presence of water / moisture / salt to maintain its conductivity
(f) Must not decompose or leach out with time.(g)Must not contain hazardous chemicals as per IEC 62561-7 standard. (h) Flexural and possess compressive strength as per relevant standard. (i) Sulphur content must be less than 2%. (j) TCLP Test shall be conducted on the material (k) material shall be inline with IEEE 80 clause 14.5.d (l) Corrosion test shall be conducted on the material under both aggressive and non aggressive conditions (m) Installation Instruction and Material DATA sheet should be printed in each package.
12
-
-
Supply , installation, Commissioning and Testing of Maintenance Free Earhting system comprising of the following :-
Ready made PVC Heavy duty earth chamber (250 mm Dia , 260 mm Height) withround cover and minimum 5 ton load bearing capacity, marking earth resistance value on it in painting Make : ERICO or techno-commercially equivalent of DEHN/ SEIMENCE complete all as specified and as directed by Engr-in-Charge.
6
-
-
S & F two run of 10mm Copper Bonded Steel Round Conductor, minimum copper bonding shall be 254 microns having continuous coin form, the conductor core consists of a low carbon steel grade for improved flexibility. The copper surface of the conductor should provide high conductivity and corrosion resistance properties, should not
crack or tear when conductor is bend well‐suited as a earth lead conductor orequipotential bonding conductor in accordance with the IEC 62305- which shall betested as per IEC 62561-2:2012 standard. Including excavation depth 50 cm for laying round conductor, removing excavated material, return filling or fixing with holder. Material category/ part number shall be listed in UL site.Make ERICO Cat Part No:CBSC10 or techno-commercially equivalent of DEHN/ SEIMENCE complete all as specified and as directed by Engr-in-Charge.
100
-
-
S & F Clamp Holder made up of 304 grade SS with SS bolt and nut at every 1 m distance of round conductor. The clamp should be suitable Copper bonded Steel round conductor size of 10-mm. Make ERICO Cat Part No CSS10 or techno-commercially equivalent of DEHN/ SEIMENCE complete all as specified and as directed by Engr-in-Charge.
30
-
-
M & L for Stainless steel Terminal connections to Equipment Body connection from maintenance free earth pit by mechanical connection using nuts, bolts and all other accessories complete as required by Engr-in-Charge. Make ERICO Cat Part No BCR10T or technocommercially equivalent of DEHN/ SEIMENCE complete all as specified and as directed by Engr-in-Charge. Note: Terminals of existing earth pits shall be cleaned for proper contact with CBSC.
8
-
-
M & L for Cadweld Materials for Connections between Ground Rod with CBSC conductor by Exothermic reaction. Connections to be made with a semi-permanent graphite mould, which shall hold the conductors to be welded. Weld metal must be a mixture of copper oxide and aluminium, should be compliant with IEEE 80 standards and tested as per IEEE 837 -2014 standard. Make ERICO Cat Part No: 115 PLUS F20 or techno-commercially uivalent of DEHN/ SEIMENCE complete all as specified and as directed by Engr-in-Charge.
8
-
-
M & L for 250x50x3 mm common bus bar for earth connection with suitable base clamps & insulators, providing "DD" universal pattern for 8 nos of holes for connections Make ERICO or techno-commercially equivalent of DEHN/SIEMENS compleate all as specified and dirtected by Engr-in-Charge.
2
-
-
M & L for Potential Equalization Clamp Connection between Power Earth & Equipment to to avoid Diffrent in Potential in Ground Make ERICO or technocommercially equivalent of DEHN/ SEIMENCE complete all as specified and as directed by Engr-in-Charge
1
-
-
M & L for Surge Protection System at Point of Entry Level Protection near to the Sub-Distribution Panel. Shunt Protection Rating of 130KA, @ 8/20micro Secound 3 Phase Protection,Triggering air gap technology provides low let-through voltage and TT power distribution systems. Max Continuous Operating Voltage (Uc): 440 VAC. Impulse Current (Iimp): 50 kA 10/350 μs.Make ERICO or technocommercially equivalent of DEHN/ SEIMENCE complete all as specified and as directed by Engr-in-Charge
1
-
-
M & L for Surge Protection System at Point of Main UPS Panel Protection near to the Equipment Room Rating of 63A Series Filter at point of entry 130KA,@ 8/20micro Secound 3 Phase Protection,Triggering air gap technology provides low let-through voltage and TT power distribution systems. Max Continuous Operating Voltage (Uc): 440 VAC. Impulse Current (Iimp): 50 kA 10/350 μs.Make ERICO or techno-commercially equivalent of DEHN/ SEIMENCE complete all as specified and as directed by Engr-in-Charge
1
-
-
M & L PVC insulated copper conductor cable 2CX10 Sqmm for making connection of earth from common bus bar to equipment including suitale clamp for fixing the cable .Make Havells or techno-commercially equivalent of Polycab/ Finolex complete all as specified and as directed by Engr-in-Charge
90
-
-
IMPROTANT NOTE FOR SER ITEM NO 19 TO 30 (1) The complete works of the Earthing system is to be got done from the OEM of their authorized sister concern/channel partner only.
(2) Design/Drawing/BOM/ Technical specifications of the complete earthing system showing the layout including dimensions is to be obtained from OEM strictly keeping in view the actual ground requirements & the same is to be got approved from Engr-in-Charge & GE before placing final order to the OEM. (3) Any items missed out in the technical specification , but technically required for efficient working of the system is deemed to be included in the unit quote rates.
(4) The contractor /Firm is required to visit the site prior to quoting of the subject items/work so as to ascertain the actual ground requirements. Any further query at a later date shall not be entertained & resposibility of the same shall rest on the contractor/firm.
(5) Comparative analysis in respect of the items wherever techno-commercially equivlent w.r.t the given Cat/Part/Model ref concerned is to be submitted to the Engr-in-Charge & GE for approval.
(6) The cost of making good the disturbed surfaces (Substation yard Stones and gravel, Walls, Pavement etc) is deemed to be included in the unit quoted rate of relevant items.
(7) On testing if the desired earth resistance is not found according to the relevant Indian Standards it is to be redone to the entire satisfaction of Engr-in-Charge at no extra cost to the Dept after completion of work contractor should submit a detailed Report of Earth resistance test result from OEM and same is to be certified from Engr-in-Charge & GE.
(8) Repair/ Preventive maintenance of the complete earthing system is to be got doen from the OEM /Sister Concern/Channel partner only by the contractor for the entire defect liability period i.e two years from the certificate date of competion & the cost of the same is deemed to be included in the unit quote rates.
(9) If any damage to any electical/communication cables or any pipe lines or any other installations occurs during execution of the work then the same shall be made good by the contractor to the entire satisfaction of the concerned & the cost of the same is deemed to be included in the unit quoted rates.
(10) Testing at an interval of 6 months of the entire earthing system is to be got done drom the OEM/Sister Concern/Channel Partner only by the contractor & report submitted accordingly to the Engr-in-Charge of the entire defect liability period & and the cos of the same is deemed to be included in the unit quote rates.
(11) Purchase Voucher & Manufacturers test certificates to be submitted in original to the Engr-in-Charge.
-
-
-