Military Engineer Services Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Military Engineer Services - MES Tender
Eprocure
Opening Date23 Nov 2024
Closing Date9 Dec 2024
Tender Amount₹ 7,70,000
Costs
EMD
₹ 15,400Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_685328_1Tender No
8027_E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Material and labour for rendering 10 mm thick in cement mortar 1:6 on fair surfaces of brick work or concrete surfaces of wall , finished even and smooth without using extra cement all as specified and as directed work in patches.
6
-
-
Material and labour for preparation of newly plastered wall surfaces, applying plaster of paris putty of 2 mm thickness and applying two coats of acrylic emulsion distemper over a coat of chalk whiting primer complete all as specified and as directed.
6
-
-
Material and labour forcomplete removal of existing treatment from old wall surfaces, applying plaster of paris putty of 2 mm thickness and applying two coats of acrylic emulsion distemper over a coat of primer complete all as specified and as directed.
49
-
-
M&L for washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4(1 cement:4 coarse sand) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement :1/2 coarse sand:2 stone chipping 10mm nominal size) in panels with groove all around as approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified.
6
-
-
Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panel and finishing the groove complete as per specifications and directions of the Engineer -in-charge.
9
-
-
Supply and installation of False Ceiling System having tiles ADVANTAGE E with micro look edge and 15mm thickness tiles or equivalent make, easily demountable tile, 15mm Gypsteel pre coated GI T Grid system in 600x600mm module which includes providing and fixing wall angle along the perimeter of the room with help of nylon sleeves and wooden screws at 300mm centers. Then suspending the main tee of size from the soffit with help of soffit cleat, rawl plugs and wire rod with Leveling spring clip at 1200mm c/c. 1200mm Cross Tee is then interlocked into the pre-cut slots in the main Tees at 600mm centers in direction perpendicular to the main Tee to make a grid of 600x1200mm. Finally 600mm Cross tees are then interlocked into the pre cut slots in the 1200mm tees at 1200mm centers and in direction parallel to the main tee to make a module of 600x600mm . Cross Tees having length more than 600mm are to be supported independently. Then laying Tile Ecophon 15mm Advantage E 595x595mm tile, Option of weekly dusting, vacuum cleaning, manufactured from High density glass wool, visible surface is a batch painted glass tissue in white, back of the tile covered with glass tissue. 83% light reflectance. Tiles classified under sound absorption class A with "alpha w " value of 0.95 at minimum 200mm o.d.s. Sound absorption test results measured according to EN ISO 354 and classification according to EN ISO 11654 and the single value rating for NRC value - 0.9 according to ASTM C 423 . Tiles should have white colour " White 500 " nearest NCS colour sample S 0500 - N with . Tiles withstand a permanent ambient RH up to 95% at 300C without sagging, warping and delaminating ( ISO 4611). Thermal resistance (Lambda value - 0,035-0,04 W/mK). Certified by the Indoor Climate labeling , emission class M1 for building materials and recommended by Swedish Asthma and Allergy Association. Product Certified under GRIHA council of India for Green Ratings . Fully recyclable . The glass wool core of the tiles is tested and classified as non combustible according to EN ISO 1182 with reaction to fire classification class A2 s1 d0 according to EN 13501 - 1 - European Standard. Tiles should have a re-cycled content of more than 70% Systems are classified as fire protective covering according to NT FIRE 003. Rate to be inclusive of approved GI exposed grid system as per manufactures specifications.
13.55
-
-
M&L for Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth: for foundation, etc, or for shafts , wells cesspits, manholes, pier holes, etc . n exc 10 Sqm on plan and n exc 1.5m in depth and getting out, in any type of soil.
13.5
-
-
M&L for cement concrete Type B2 1:4:8 (40mm graded aggregates) in foundations, filling and mass, complete all as specified.
0.7
-
-
S&F for Formwork to flat sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter,Rough finished surfaces of concrete complete all as specified.
12.8
-
-
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified.
227.7
-
-
M&L for cement concrete M-25 (20mm graded aggregates) foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified.
1.9
-
-
M&L for Pre-cast cement concrete block type B1 1:2:4 (20mm graded aggregates) masonry with solid blocks, exc. 10 cm in width and setting in mortar 1:4, complete.complete all as specified.
0.6
-
-
S&F for plates Fe 410-W (GdeE- 250) quality A (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes,with riveted, bolted or welded attachment, complete all as specified.
3.9
-
-
S & F Rolled mild steel sections Fe 410-W (GdeE- 250) quality A as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates,complete all as specified.
663.4
-
-
S&F for steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240,complete all as specified.
368.6
-
-
M&L for pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
27.8
-
-
M&L preparation of new or previously untreated steel and iron surfaces plain or moulded, n exc 10cm width or girth when unconnected with other painting or when painted in a different tint,and applying two coats of synthetic enamel paint over a coat of primer, complete all as sfd and directed.
0.4
-
-
M&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
217.9
-
-
M&L for soil Spreading and levelling in layers n exc. 25 cm thick in floor,well ramming including watering as required, complete all as specfied.
0.6
-
-
M&L for 100mm thick broken stone or boulder,Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified.
2.5
-
-
M&L for plain cement concrete 100 mm thick of 1:4:8, type D-2 (using 40mm graded crushed stone aggregate) as in levelling course of sub floors, sub-base, floors and paving etc., complete all as specified and directed.
25.2
-
-
100 mm thick PCC 1:2:4, type B-1 using 20 mm graded stone aggregates as in floors and pavings finished even and smooth without using extra cement.
25.2
-
-
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) to stone and rubbish off the premises complete all as specified and directed.
26.6
-
-
Demolition of concrete in ground floors and pavings n. exc 15 cm thick complete all as specified and directed.
2
-
-
M&L for Cement concrete type B-1, 1:2:4 (20mm graded aggregate ) 40mm thick for sub base of floors complete all as specified and directed.
26.6
-
-
M&L for Screed bed or bedding layer of mortar 20 mm thick in CM 1:4 for laying floor finishes, complete all as specified.
26.6
-
-
M & L for vetrified Light shade ceramic tiles 10mm thick (square / rectangular) area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors,etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface all as specified and as directed by Engr-in-charge..
12.9
-
-
M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces with CM 1:4 as in backing coat of skirting /dado, complete all as specified and directed.
1.4
-
-
All as per item No 31 above but as in for work on vertical surfaces such as skirtings, dados and risers to steps etc skirting all as specified and as directed by Engr-in-charge.
1.4
-
-
M&L for Colour heavy duty vetrified garden tiles 300mm x 300mm x15mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface all as specified and as directed by Engr-in-charge..
13.8
-
-
Demolition for precast concrete block walling, built in cement mortar or cement lime mortar, complete all specified.
0.3
-
-
Removing excavated soil not exc 50m and depositing where directed at a level not exc 1.50m above the starting point.
7.5
-
-
Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thickness with hard/dense soil all as specified and as directed.
6
-
-
Earth cushioning to UG cables using excavated soil riddled by using large sieve to separate the composite particles/roots etc and refilling in trenches all as specified and as directed. Note: Punned thickness will be measured for payment.
3
-
-
Supply and lay burnt bricks sub-class 'B' designation 75 for cable protection all as specified and as directed.
0.25
-
-
M&L for dismantling / cutting of existing road / path / hard standing cement concrete (unreinforced) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) suitable for laying cable protection pipe 80 / 50 mm dia under the road / path / hard standing complete.
0.65
-
-
Material and labour for PCC (1:2:4) type B-2 (using 40 mm graded crushed stone aggregate) for making good the disturbed surface of road/path/hard standing by using cement contrete mortar 1:2:4 type B1, using 40 mm graded stone aggregate 0.45 mtr wide and 0.15 mtr thick complete all as specified and directed. including demolition of old PCC and removing the debris from site complete all as specified and as directed at site by the Engr-in-Charge.
0.65
-
-
Supply and laying GI pipe light grade 80 mm bore including all type fitting such as bends, elbows, tee etc fixed on / concealled in walls/to poles/laid in trenches as cable protection all as specified and as directed.
6
-
-
Supply and laying GI pipe light grade 50 mm bore including all type fitting such as bends, elbows, tee etc fixed on / concealled in walls/to poles/laid in trenches as cable protection all as specified and as directed.
4
-
-
Supply, layig, connecting, testing and commissioning of 50 Sqmm 3.5 Core under ground LT cable XLPE insulated screened, PVC bedded, armoured heavy duty electric cable confirming to IS : 7098-1985 with stranded aluminium conductor 1100 volts laid in trenches, floor, fixed to walls/drawn through pipe, duct or along the pole and incl the disturbence surface of road making good with using PCC, fixing the cable with suitable size glands, crimping type lugs etc all as specified and directed. Make: Havells/Polycab/Finolex/Paragon/Gloster/Nicco
30
-
-
All as per Item No 44 here - in - before but 10 Sqmm 2 core complete.
30
-
-
S&F 6 Way VTPN DB's upto 125 Amp incomer, Double door, IP-54, K-09 made up of CRCA sheel steel, 415 Volt provision with 100 Amp aluminum insulated phase vertical bus bar with neutral bar and earth bar, sticking saddles, cement spill protector, colour coded intgrated wire set, cable ties, blank plates and circuit identification labels, with provision for 3 Pole and 4 Pole MCCB as incomer and as SP / TP MCB's as outgoings including concealed and fixing on wall complete. Make: L&T/Legrand/ Havells/Indoasian
1
-
-
S&F 63 Amp MCCB's 415 Volt, 16 KA, 4 Pole in exiting VTPN DB incl electric UG cable connection complete.
1
-
-
Supply and fix MCB SP 6 to 32 Amps, 240Volts, 10 KA, "B" Curve complete. Make: L&T/Legrand/ Havells/Indoasian
16
-
-
M&L Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 M below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt , earth lead GI wire 4mm dia ( 8 SWG) connectd to GI earth plate elcectrode by means of bolts, nuts, check nuts, washers of galvanised iron, thimbles and other end of earth wire connected to main switch board/ feedar pillar and protected by galvanised iron pipe light grade 15mm bore and 20 mm bore medium grade GI pipe with funnel and wire mesh for watering including necessary excavation and earth works. PCC Chamber in cement concrete 1:2:4 type B-1 & RCC cover and all as shown in Electrical Plate No. 3 of SSR ( Part-I) of 2009. (i) The unit rate includes earthing wire, and protection pipe upto 7.5 metre.
1
-
-
M&L for concealed Sub main wiring fixing in wall/surface floor/concealed etc complete with 2 runs of 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 1 run of 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm or higher dia non metallic rigid PVC conduit and conduit accessories suface/concealed in wall/Ceiling etc from Main DB to MCB DB all as specified and as directed by engr - in- charge. Note :- 2 runs of 1.5 sqmm, + 1 run of 1.5 sqmm (Earth Cotinuity conductor) and 1 run of PVC conduit shall be measured as one unit length.
20
-
-
All as per item No 50 Above but 6.0 Sq mm
15
-
-
All as per Item No 50 above but 2.5 sq mm.
20
-
-
All as per Item No 50 above but 4.0 sq mm.
15
-
-
Supply and fixing for straight through cable jointing kit heat shrinkable type joint for 1100 volts grade cable complete with jointing material and accessories suitable for 3.5/4 core XLPE/PVC insulated armoured aluminium conductor cable for the size 25 to 50 sqmm all as specified and directed. Make - Raychem, M seal, Denson etc
2
-
-
S&F 100 Amp Bus bar box, 4 Way (Wall mounted) factory made IP65 CRCA sheet with openable shutters on front sides having locking arrangement totally enclosed weather proof, Outdoor type, suitable for 440 volts, 3 phase, 4 wire, 50 cycles with outer shell contains a detacheable plate having provision for entry of adequate size with PVC glands with cable including taking down old bus bar box any type and reconnect the incoming/ outgoing LT cables complete. (Make : L&T, Havells, C&S, Legrand & Indoasian)
1
-
-
M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring etc. and making good, cutting not exc 10 cm girth complete.
65
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%