Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Military Engineer Services - MES Tender

Works
Civil And Construction
Eprocure
Opening Date25 Sep 2024
Closing DateCancelled
Tender Amount₹ 14,27,00,000 
Notes
Download

Costs

Summary

801612 Provision Of Deficient Married Accommodation At Af Stn Sulur Ph I

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Lumpsum price worked out by the contractor for “Internal Water Supply” as listed in Schedule ‘A’ Part–II

1

-

786472.96

... More
Lumpsum price worked out by the contractor for “Internal Electric Supply" as listed in Schedule ‘A’ Part–III

1

-

4237414.93

... More
Lumpsum price worked out by the contractor for “Site clearance and development" as listed in Schedule ‘A’ Part IV .

1

-

421550.55

... More
Lumpsum price worked out by the contractor for "Road/Path/culvert" as listed in Schedule ‘A’ Part V .

1

-

6463982.63

... More
Lumpsum price worked out by the contractor for “Sewage Disposal” as listed in Schedule ‘A’ Part – VI.

1

-

536280.51

... More
Lumpsum price worked out by the contractor for “Area Drainage” as listed in Schedule ‘A’ Part – VII.

1

-

1919762.97

... More
Lumpsum price worked out by the contractor for “External Water supply (E/M)” as listed in Schedule ‘A’ Part – VIII.

1

-

260244.39

... More
Lumpsum price worked out by the contractor for “External Electric Supply ” as listed in Schedule ‘A’ Part – IX.

1

-

888221.43

... More
Lumpsum price worked out by the contractor for “D G SET” as listed in Schedule ‘A’ Part – X.

1

-

45437.4

... More
Lumpsum price worked out by the contractor for “Fire fighting ” as listed in Schedule ‘A’ Part – XI.

1

-

658518.5

... More
Lumpsum price worked out by the contractor for “LIFT” as listed in Schedule ‘A’ Part – XII.

1

-

4907900.6

... More
Lumpsum price worked out by the contractor for “Lighting Protection” as listed in Schedule ‘A’ Part – XIII.

1

-

140804.5

... More
Lumpsum price worked out by the contractor for “Aviation Obstruction Light” as listed in Schedule ‘A’ Part – XIV.

1

-

7656.6

... More
Sch 'A' Part - IA : BUILDINGS OR WORKS Design and Construction of Md Accn for Sergeant /Cpl including covered GF stilt parking in 7 storey (Ground+6 storey) with using 3D monolithic modular Technology / precast construction in RCC of grade as per structural drawings with Cast in Situ foundation with ATT, PU based WPT, earthquake resistance as per latest IS, UPVC window and Green building norms with GRIHA three star rating etc complete all as specified and as shown on drawings. (Note: The quoted rate against is deemed to included for the provisions contained in Sch 'A' Notes. Refer Sch 'A' Notes complete before quoting these items. Structural design and structural drawings for super structure and foundations for the building/structure shall be prepared to comply with the provisions for design and analysis of RCC structures as per latest editions relevant IS Codes).

1

-

-

... More
Design and Construction of Pump house in RCC of grade as per structural drawings, AAC Block masonry, ATT, PU based WPT, earthquake resistance as per latest IS, UPVC window and Green building norms with GRIHA three star rating etc complete all as specified and as shown on drawings. (Note: The quoted rate against is deemed to included for the provisions contained in Sch 'A' Notes. Refer Sch 'A' Notes complete before quoting these items. Structural design and structural drawings for super structure and foundations for the building/structure shall be prepared to comply with the provisions for design and analysis of RCC structures as per latest editions relevant IS Codes).

1

-

-

... More
Sch 'A' Part - XV : Fittings / Fixtures & Misc items. INTERNAL WATER SUPPLY S&F 15 mm bore kitchen sink tap, brass chromium plated dual flow pattern with silicon black flexible hose swivel type complete all as specified and as directed.

30

-

-

... More
S&F 15 mm bore washing machine tap, brass chromium plated complete all as specified and as directed.

30

-

-

... More
INTERNAL ELECTRIC SUPPLY Supply and Fixing Surface mounted square panel light fiting 1ftx1ft of 18W, 220Volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers suitable for roof ceiling in and including connecting up with three core flexible copper conductor cable of suitable size and connected accessorie etc. complete in all as specified and as directed .

49

-

-

... More
S&F TPN vertical Distribution board 8 Way, Protection class IP-43 Double door suitable for incomer MCCB suitable upto 160 Amps and outgoing MCB TPN/SP MCB with minimum 200 Amps rating bus bar etc. complete in all respects all as specified and as directed .

1

-

-

... More
S&F TPN vertical Distribution board 4 Way, Protection class IP-43 Double door suitable for incomer MCCB suitable upto 160 Amps and outgoing MCB TPN/SP MCB with min 200 Amps rating bus bar etc. complete in all respects all as specified and as directed .

1

-

-

... More
Supply and fixing MCCB 4 Pole, 415 Volts, Adjjustable Thermal & Fixed magentic type 100Amps wiht breaking cpacity 16 KA etc. complete in all respects all as specified and as directed.

1

-

-

... More
Supply and fixing MCCB 4 Pole, 415 Volts, Adjjustable Thermal & Fixed magentic type 63 Amps wiht breaking capacity 16 KA etc. complete in all respects all as specified and as directed .

1

-

-

... More
Supply and fix Modular TV Socket, one module etc complete in all respect all as specified and as directed .

60

-

-

... More
M&L TV Wiring with unarmoured co-axial cable,RG-11 in and including concealed with PVC Conduit 25 mm dia etc complete in all respect all as specified and as directed.

510

-

-

... More
EXTERNAL WATER SUPPLY/ EXTERNAL ELECTRIC SUPPLY. Cutting cast iron and reducing to required length before laying pipes in position for insertion of new tees,branches of different sizes as per site requirement for 150 mm bore complete all as directed.

1

-

-

... More
Supply and laying ductile Iron pipe , S/S including specials, Class “K-7” ,100 mm dia complete all as specified and as directed.

400

-

-

... More
Supply and fix Non return valve 80 mm dia complete all as specified and as directed.

2

-

-

... More
Supply and fix CI foot valve 80 mm dia to suction line of exisiting pumping set with bolts, nuts, rubber packings, etc complete all as specified and directed.

2

-

-

... More
Construction of valve chamber with inner clear dimension 600 x 600 x 900mm suitable for 80mm sluice Valves with PCC (1:4:8) 150mm thick type D2 for foundation, Brick masonary 230mm wall in CM (1:4), PCC (1:2:4) 75mm type B1 for coping, rendering in CM (1:4) 15mm thick including provisiion of 3mm thick MS sheet cover and 25 x 25 x 3mm angle frame embeded in coping with two coats of synthetic enamel paint over a coat of red oxide primer with locking arrangements including necessary earth work complete all as specified and directed .

2

-

-

... More
M&L for DI fitting bend (any type, radius and angle) tapers tapers any type (straight, bend, increasing, decreasing or double socket), Tee piece , connection pieces, collers, caps and plug etc complete all as specified and directed.

720

-

-

... More
Supply and installation of Booster pumps for 440 V, 3 Phase, 50 Hz Confirming to IS- 12469 :1988 With CI Casing bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for 440 volts, 3 phase, 50 Hz 30m head, 900 LPM discharge & 3.5 KG/CM2 all as directed.

2

-

-

... More
Supply, laying & testing of PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 4 sq mm ,3 core, 1100 Volts grade complete all as specified and as directed.

80

-

-

... More
S&F LT panel outdoor type made out of MS sheet 2 mm thick with locking arrangement and painting with in and including following asseccories suitable for incoming / outgoing arrangements:- (a) MCCB 100 AMP 25KA 4 pole - 01 No (b) DOL starter suitable for 5 HP, 415 V AC - 01 No (c) MCB TPN 40 A - 03 Nos (d) MCB SPN 6-32 AMP, 10 KA - 02 Nos (e) DOL starter suitable for 10 HP, 415 V AC - 02 No (e) Aluminium bus bar 200 Amp TPN - 01 Set (f) LCD multi function meter - 01 No (g) Indicating lamp set -01 Set of three (h) CT of suitable ratio 100/5 A - Set of 3 Nos

1

-

-

... More
M&L Earthing with Galvanised Earth Plate Electrode 600 x 600x 3mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 32x6mm (upto 7.5m length) by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete (1:3:6) using 20mm graded crushed stone aggregate and Pre-cast RCC Cover Slab of size 350 x 350 x 50 mm in Cement Concrete (1:2:4) using 20mm graded crushed stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in any type of soil, Returning, Filling in and Removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one, complete all as specified and as directed.

2

-

-

... More
M&L Earthing with Galvanised Earth Plate Electrode 600x600x 3mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth wire of 4 mm (upto 7.5m length) by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in any type of soil, Returning, Filling in and Removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one, complete all as per specified and as directed.

2

-

-

... More
Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming complete all as specified and directed.( Note :- In case sufficient sand not obtained from excavation, the quoted rate is deemed to be inclusive for the required additional qty obtain from out side MD land as directed .)

46.98

-

-

... More
M & L for Protection to cable with one layer of Fly ash bricks of size 23 x 10 x 10 cm laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable complete all as specified and as directed.

5800

-

-

... More
Supply and fixing 11KV, 3 phase 20KA/3sec, 50Hz totally gas insulated OUTDOOR SAFEPLUS compact ring main unit (Type:CCV+) consisting of 2 nos manual operated, fixed type (non draw out type) 630 A load break switches as incomers and 1 No manual operated fixed type (nondraw out type) 630 A vaccum circuit breaker as out going complete in a 2.5mm/ more robotically welded stainless steel tank of IP 67/ more class of protection with 350 MVA rupturing capacity, overload & earth fault protection by 350 MVA rupturing capacity, overload & earth fault protection by self tank powered relays (ASHIDA make ADR 1415/ABB make REJ 603/ or its equivalent. The panel should be with ring core as per the transformer rating 2.5 VA class 5P10 ) all as specified and as directed.

1

-

-

... More
Shifting, installation and testing of copper wound transformer step down, outdoor type complete with standard fittings, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as per IS:2026 of capacity upto 200 KVA from existing site to prop site (Appx 3 KM around) complete all as specified and directed.

1

-

-

... More
M & L for Making of platform including masonary work for transformater of size of 2.00 M x 2.00 M x 2.00 Mtr including fencing complete all as specfied and as directed.

1

-

-

... More
Supply, Install, and commissioning LT feeder pillar (CPRI approved) Outdoor typeIP-65 made out of 3.15 mm thick MS sheet and angle Iron frame work, cubicle type with copper bus bars and with suitable mounting plate, frame and canopy, confirms to IEC61439-2 with following accessories suitable for incoming/outgoing arrangements:- (a) MCCB with extended rotary handle and spreader link 320 A 35kA 4 pole - 01 No (b) MCCB with rotary handle and spreder link 160 AMP 25kA 4 pole - 01 No (c) MCCB with rotary handle and spreder link 125 AMP 25kA 4 pole - 01 No (d) MCCB with rotary handle and spreder link 40 AMP 25kA 4 pole- 01 No (e) Digital panel meter for voltAmp/Volt/KWH&PF - 01 No (f) LED indicating lamp set- 01 Set of three (g) Timer Switch 20 Amps (h) Channel size 70x40x6MM suitable for LT Panel Load (j) PCC foundation as per OEM drg. complete all as specified and as directed.

1

-

-

... More
M & L for GI bracket suitable for street light fittings bend to required shape made up of dia GI tubing 40mm dia medium grade of length 1.50 Mtr including clamps nuts bolts washers complete all as specified and directed.

8

-

-

... More
Supply and fix Synchronising electronic timer unit operated on AC 230 Volts, 24 hrs clock time for controling street lights/ flood lights etc all as directed.(Make :- Cat Part No : 4126 41 of Legrand or equivalent in L&T, ABB as approved by GE)

1

-

-

... More
Supply and fix Power contactors 63 Amps, 4 pole, 415V etc all as directed .( Make : Cat No 4125 57 of Legrand or equivalent of L&T/ Siemans as approved by GE)

1

-

-

... More
Supply and fix junction box size not less than 280x 170x 130mm made of UPVC with aluminium bus bar of 50Ams for phase and neutral on porclein based installation fixed on pole with help of MS nut bolts MS clamps 2 Nos not less than of size 40mm x 4mm fuse with one No MCB SP 6 Amp capacity mounted on rail inside box work also includes making suitable hole in pole to take out connection to fitting if required at site complete all as specified and as directed.

8

-

-

... More
M & L for 02 Nos single core copper conductor PVC unarmoured cable of size 2.5 sqmm and 01 No. copper conductor cable of size 1.5 sqmm for earth. 1100 Volts grade PVC insulated and PVC sheathed cable through wall/ pole etc including PVC conduit of 20 mm dia appx length 08 mtrs complete all as specified and as directed.(Note:- 1 RM of 2 nos single core 2.5 sqmm copper coductor and 1 RM of 1 no 1.5 sqmm copper conductor cable shall be considered as one unit for one RM).

64

-

-

... More
DG SET Supply, installation,testing and commissioning of silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, engine as per IS:10001/ 10002 and Alternator as per IS: 13364 complete with relay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms - IV and foundation etc. of capacity upto 40 KVA. complete all as specified and as directed.

1

-

-

... More
Supply, installation, commissioning and testing of Stainless steel Retro-fit Emission control equipment able to capture specified particulate matter (PM 2.5) emitted from 40 KVA stand by DG with capturing efficiency of minimum 90% and hold 5.5 kibipascal backpressure excerted by DG sets, with min operating Temperature (-)15 Deg celsius, Max operating Temperature 750 Deg Celsius, Operating Humidity up to 90% (Non - Condensing) corrsion resistive construction complete all as specified and directed.

1

-

-

... More
FIRE FIGHTING S&F Clean Agent based stand alone automated Fire Suppression system HCFC123-10 KG complete all as specified and as directed.( Make- Ceasefire/Model No.CF000771 or equivalent as approved by GE)

4

-

-

... More
Supply, laying,testing and commissioningTerace Pumping sets, centrifugal, electric driven, supply and Install complete capacity of 900 LPM and 3.5 KG/CM2 inclusive of starter and suitable PCC foundation complete all as specified and as directed.

1

-

-

... More
Supply and install testing and commissioning of yard hydrant consisting of the following components complete all as specified and as directed:- (a) 63 mm dia instantaneous pattern oblique hydrant with chain cap (b) 63 mm dia size controlled peculation hose of 2 Nos 15 mtr with gun metel female instaneous coupling as necessary. (c ) Sheet steel fabricated hose cabinet of suitable size power coat painted to house the above accessories. (d) one set of branch pipe made of gun metal.

7

-

-

... More
Supply and laying of PVC insulated PVC sheathed wire armoured with multi stranded copper conductor of size 4 Sqmm 4 core 1100 volts grade complete all as specified and as directed.

150

-

-

... More
Supply only Dry Chemical Powder (ABC) 4 KG complete all as specified.

7

-

-

... More
Supply only Light weight squeeze grip type type CO2 Type Extinguisher (IS: 15683) - 3 Kg capacity omplete all as specified.

9

-

-

... More
Supply only Fire Extinguisher water (Stored pressure type) 9 Ltr capacity omplete all as specified.

7

-

-

... More
Supply only Dry chemical powder extinguisher 9 kg omplete all as specified.

4

-

-

... More
Supply only Light weight squeeze grip type type CO2 Type Extinguisher (IS: 15683) - 4.5 Kg capacity omplete all as specified.

2

-

-

... More
Supply only Mechanical foam type Fire Extinguisher (IS: 15683) - 9 Ltrs capacity omplete all as specified.

4

-

-

... More
Supply and fixing Fire Buckets-02 Nos (IS: 2546) including fire point made of PCC bed, MS pipe of 40mm dia, CGI sheet etc.as specified and as directed.

4

-

-

... More
LIFT Supply and fix 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 25 KA complete all as specified and as directed.

2

-

-

... More
LIGHTINING PROTECTION Supply and fix epoxy base insulators of suitable size 40mm height for fixing GI earth strip on wall/ceiling/floor/poles etc complete all as specified and as directed.

350

-

-

... More
AVIATON OBSTRUCTION LIGHT Supply and fix aviation obstruction light LED type comprising of aluminium housing with polycarbonate enclosure complete all as specified and as directed. (Make Bajaj Cat No. BGAV 302 LED or equivalent as given in PS and as approved by GE)

2

-

-

... More
S&F DP MCB 6 A with enclosure complete all as specified and as directed.

2

-

-

... More
Supply and fix time switches 250 V single Phase of 20 Amp rating with contactor fitted inside steel enclosure complete all as specified and as directed.

2

-

-

... More
SMART PREPAID METER Design, installation, testing, commissioning, integrate and maintain the Advanced metering infrastructure (AMI) Comprising of following:- (a) Supply, installation, testing, commissioning of smart meter AC single phase, two wire, 240 volts, 50Hz, 10 to 60 amps of different makes (not more than 33% of a particular make to ensure interchangeability at a later date as per BIS 16444 with communication technology including GPRS / RF / Hybrid (GPRS+RF) any other advanced technology as per CEA/TRAI regulations). (b) Supply / planning / setup/ tuning of RF communication infrastructure including Network Management (NMS) & Head End system (HES) for the project area. AMI software and associated equipment should be capable of handling atleast 10000 number of meters of different makes as per BIS 16444 with 25% expansion without any additional infrastructure and cost implication to MES. (c) Supply and setup of Meter Data Management (MDM) System. (d) Integration of different devices of different makes/equipment/softwares covered in scope of this project with each other as per functional requirement, including water charges, furniture and license fee.

30

-

-

... More
(e) Integration/ interface of the AMI system with application system like metering/billing/collection, interface has to be provided in the proposed solution to upload and process meter data from these systems. (f) Server for housing and management of supplied software application with Standby server (OR) hosting the system to government community cloud in place of server for hosting and management of supplied software application with standby server. (g) Planning, deployment & tuning of communication system including cellular network (if required) to meet the performance requirements. (h) Business intelligence, Analytics and Reporting. (j) Taking down & Return of dismantled materials to MES Store. (k) Training and knowledge transfer. (l) All expenditure including periodic charges of telecom operator from installation till completion. (m) Comprehensive operation and maintenance of AMI system including project implementation & management, all expenditure including periodic charges of telecom operator, smart meter billing and maintenance, for a period of 10 years post completion of work.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.