Chennai Metropolitan Water Supply And Sewerage Board Tender

... More
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Chennai Metropolitan Water Supply And Sewerage Board - CMWSSB Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date2 Jan 2025
Closing Date21 Jan 2025
Tender Amount₹ 45,61,441.57 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, delivery, conveying and fixing following sizes of DI specials of DI push - on joint specials as mentioned below conforming to IS: 9523/2000 including loading, unloading and stacking at the site etc as directed by the engineer at site, and including earthwork excavation, refilling with excavated soil, watering and ramming to consolidation and disposal of surplus earth etc complete.

-

-

-

... More
150mm dia MJ Collar

10

5142

51422

... More
150mmx80mm D/f reducer

1

5092

5092.1

... More
150mm dia SV with tail piece

2

16803

33607.8

... More
80mm dia Air valve

1

7642

7642

... More
600mm X 600mm X 150mm dia All soc TEE

1

67690

67690.6

... More
80mm dia SV

1

6270

6270

... More
600mm dia MJ Collar

2

38903

77806.6

... More
150mm dia 90 DI bend

1

3443

3443.6

... More
Making rubber joint ( Labour only )150mm dia

116

304

35264

... More
Making rubber joint ( Labour and material )150mm dia

14

325

4550

... More
600mm dia (laour cost )

6

1230

7380

... More
Making Flanged joint

-

-

-

... More
For 150mm dia

4

304

1216

... More
80mm dia

1

185

185

... More
Cutting of DI pipes

-

-

-

... More
For 150mm dia

15

356

5340

... More
Testing of D.I.pipes with hydrulic testing equipment by fillling with water and testing to recommended pressure in convenient sretches and attending the bursts if any occurred during the test, excluding the cost of pipes, including other incidental and operational charges,etc., complete. (150 mm dia)

635

140

88900

... More
Construction of chamber for 100mm to 250mm dia. sluice valve including providing and fixing FRC cover and frame of size 60 x 60cm for size 1.35 x 1.2 x 1.55 m

2

60000

120000

... More
Construction of 80mm dia Double air valve chamber for 100 to 350mm dia pipe line including providing and fixing FRC cover and frame of size 60x60cm for size1.2x0.9x1.8mtr

1

54000

54000

... More
Construction of thrust block using CC 1:3:6 using 40mm BG jelly for PCC for 90 Bend (@ 2m depth)

5

9306

46530

... More
CC 1:3:6 using 12 to 20mm HBG jelly for making smooth surface to the road users

96

5874

563904

... More
Disposal of surplus earth at pipe laying portion at SV portion at Air valve portion

104.16

147

15358.39

... More
Providing Iron Barricading of size 2.50 m width and 1.75 m height using 40x40x4 mm angle for outer frame supports, 25 x 25 x 3 mm angle for inner frame supports and 20 gauge thickness MS sheet for name board (as per drawing) including cutting, welding,fabrication charges and one coat of primer and 2 coats of enamel paint of approved quality, writing "METRO WATER" & work detail/ caution sign, providing necessary interlocking arrangements with adjoining units, fixing danger flags, danger lights, reflectors, fixing stickers etc, including watching during night and placing the barricading units as directed at the sites

1270

92

116840

... More
Hire charges for diesel pumpset for 5HP

240

354

85197.6

... More
Misellaneous Item

-

-

-

... More
Engaging Labours for fixing the interconnection with 600mm dia pipe to 150mm dia DI pipe with necessary Bolt and nuts for tapping water

-

-

-

... More
Hiring JCB

2

6272

12544

... More
Fitter class I

6

1065

6395.4

... More
Fitter Class II

6

1035

6210.6

... More
Mazdoor category I

4

787

3150.4

... More
Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304)/ Die cast Aluminium/ Carbon steel with anticorriosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP68 Protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished.

-

-

-

... More
100 MM Meter

1

104358

104358.8

... More
Supplying ,delivery ,conveyance and fixing of the following DI of specials ( Flow Meter )

-

-

-

... More
100 mm DI pipe double flange ( 500 mm length )

1

2626

2626

... More
100 MM DI pipe double flange ( 1500 mm length )

1

5808

5808

... More
100 mm flanged spigot tail piece

1

2258

2258.9

... More
100 MM Flanged socket tail piece

1

1963

1963.1

... More
100 MM Dismantling Joint

1

6200

6200

... More
Construction of Water meter chamber-100 mm size including providing and fixing FRC cover

1

183300

183300

... More
The Contractor must obtain the existing Static GCP points from CMWSSB which should be considered as the control point with known coordinates X, Y and Z. Survey consultant to ensure the closing error is within permissible limits (SoI Standards) while transferring the levels from the existing Static GCP points and the same to be presented as a report. The same process shall be adopted for random verification of positional accuracy of points established using the PBMs as base. As built survey for every sewage and water pipeline and other assets must be done using DGPS based RTK method by transferring the coordinates from the nearest Static GCP of CMWSSB. Where there are signal interruptions for the RTK method, Total Station can be used. The coordinates from the static GCP shall be transferred to the Total Station by RTK method and the co- ordinates of the assets can then be captured by Total Station. All the features, attributes of all the assets, utilities captured shall be Geo referenced as per standard Coordinate reference system (WGS 84 UTM Zone 44N).

-

-

-

0.64

22154

14178.56

... More
Sub Total

1

10

-

... More
GST @ 18%

1

10

695813.12



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.