Public Health Engineering Department Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Public Health Engineering Department - PHED Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date17 Jul 2024
Closing DateCancelled
Tender Amount₹ 5,56,30,153 
Notes
Download

Costs

  • EMD

    ₹ 11,12,603
  • Document Cost

    ₹ 10,000
  • Tender Fee

    ₹ 2,500

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Add 15%extra on above item for drilling depth beyond 100 mtr, If depth of Tube well is more than 100 mtr.

180

29538

164.1

... More
Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date of following sizes

-

-

-

... More
200 mm dia NB (Thickness of pipe 5.4 mm & mass of tube 28.46 Kg/m)

45

122175

2715

... More
Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug.

-

-

-

... More
200 mm dia nominal bore

3

3090

1030

... More
Rising Main

-

-

-

... More
Providing, lowering, laying in trenches,aligning,fixing in position, Jointing Ductile Iron (DI Spun) ISI marked K-7 grade S&S pipes as per IS 8329: 2000 (amended up to date) with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS :5382-1985 including special (tees, bends etc.) complete including all material, labour, hydraulic testing and commissioinig (excluding eartwork) as per technical specifications and direction of Engineer in charge, with Excise Duty Exemption. Note: Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.

-

-

-

... More
DI K-7 Pipe 200 mm dia

9700

28207600

2908

... More
DI K-7 Pipe 150 mm dia

500

1139500

2279

... More
DI K-7 Pipe 100 mm dia for T/Ws

900

1445400

1606

... More
DI K-7 Pipe 100 mm dia for Pumping

1500

2409000

1606

... More
Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
Manually Operated Resilient Seated Sluice Valves of Class PN /1.6

-

-

-

... More
200 mm dia

3

95094

31698

... More
150 mm dia

2

41036

20518

... More
100 mm dia

12

141600

11800

... More
Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) Swing type Non Return Valve of approved make of following Pressure rating & dia complete, generally confirming to IS: 5312 (part -1)/ 2004 (amended up to date) and of following specifications: Body, Bonnet & disc of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per IS 5312 (part -1):2004 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body, cover and disc inside and outside . Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS.Shaft of SS- AISI- 410, Hinge SS AISI 316/410 ,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR "O" ring seal Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.

-

-

-

... More
Class PN 1.6

-

-

-

... More
100mm dia

3

37233

12411

... More
150 mm dia

1

21451

21451

... More
200 mm dia

3

106536

35512

... More
Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Body Flanged End Tamper proof Kinetic Air Valve of approved makes of following pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(ammended up to date),Body, High pressure cover , Low pressure cover, Cowl and Joint support ring - Grey cast iron of grade IS:210/FG200 ,Float- LP ball & HP ball : AISI 304 stainless Steel, Float Guide- HTB1,Seat ring & Gasket - EPDM/NBR, HP Orifice & HP orifice plug : HTB2/ SS ,Bush: Bronze , Flanges as per IS/ BS, Drilled as per IS:1538. Epoxy paint (Non-Toxic & suitable for drinking water) applied on body & cover inside and outside Fastners - CS/ Galvenised steel ,Outlet of big orifice will have a screen to prevent Tamper of float, with CI metal seated D/F Non rising stem Sluice Valves as per (IS: 14846 amended upto date) PN 1.0 ratings Valves including all mateial, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work.

-

-

-

... More
Class PN 1.6

-

-

-

... More
50 mm

5

75600

15120

... More
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches for water supply pipe lines, shoring and strutting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for lifts up to 1.5 depth and strata as specified. The work also includes depositing and refilling of trench with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed for lead up to 50 mtr.

-

-

-

... More
All kinds of soil

4234

863736

204

... More
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and stacking serviceable material for measurements and disposal of unserviceable material as directed, with in a lead of 50 Mtr. including all safety provisions required .:

-

-

-

... More
Ordinary Rock

4234

1549644

366

... More
Hard Rock ( Requiring Blasting )

1058

577668

546

... More
Hard Rock ( Blasting prohibited)

1058

983940

930

... More
Dismantling of cement concrete pavement for pipe line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work.

120

90720

756

... More
Dismantling of flexible pavement for pipe line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work.

-

-

-

... More
Bituminous courses

60

24960

416

... More
Granular courses

90

26640

296

... More
Providing and laying in position cement concrete 1:3:6 (1 Cement : 3 coarse sand :6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, complete work as per technical specification and scope of work.

135

647595

4797

... More
Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, complete work as per technical specification and scope of work.

-

-

-

... More
M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).

135

878445

6507

... More
Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per Highway/ Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved by authority specification and the direction of the Engineer. Apply corrosion, resistant, protection on inside and outside of casing pipe as per technical specification.

-

-

-

... More
400 mm Dia 8 mm thick casing pipe.

120

2621760

21848

... More
Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths DI standard specials with rubber ring (EPDM)/ nut bolt and insertion sheet and jointing as per IS: 9523-2000 or as amended up to date, such as tees, bends, tapers, caps etc. within trenches in DI pipe line complete including all material, labour, taxes, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge (excluding earth work).

-

-

-

... More
All End Socketed

-

-

-

... More
Up to 300 mm Diameter

200

30200

151

... More
Construction of RCC Sluice valve chamber for different type of valves including earthwork excavation, 100mm PCC M15 as leveling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as directed by Engineer-in-Charge.

-

-

-

... More
For Class-AA loading

-

-

-

... More
Sluice valve chamber of size 1.26m x1.185m x1.88m for pipe size-from 200-to-300mm

-

-

-

... More
For in-campus Valve Chambers

-

-

-

... More
Sluice valve chamber of size1.13m x0.85m x1.225m for pipe size-upto100mm

8

238528

29816

... More
Sluice valve chamber of size1.17m x0.95m x1.37m for pipe size-from 125-to-150mm

1

33504

33504

... More
Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge.

-

-

-

... More
MS pipe specials up to 600mm dia (with minimum 5mm thickness sheet)

325

41925

129

... More
Construction of Pumpsets

-

-

-

... More
Supply & Installation of three phase ISI marked submersible motor pump set of five star rating of BEE & as per IS:8034-2011(Pump) & IS:9283-2013(Motor) or amended upto date of aprroved make of following duty condition with required accessories including making connection suitable for Tube well/ DCB. The job includes lowering of motor pump insatallation of complete fitting & accesorries jointing of electrical cables up to switch board, testing of submersible pump sets & interconnections upto water mains, complete in all respect.

-

-

-

... More
Submersible pump sets for tube wells (150 LPM 160 M Head 4 Nos ) 7.5 KW (10 HP) & head above 120 mtr. including 1No Standby Sets.

30

236430

7881

... More
11.0 KW (15.0 HP) & Head Upto 120mtr. (11.11 LPS/ 45.0 Mtr.) 02 No. Pump sets including 100% Standby Sets.

22.5

133695

5942

... More
Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at synchronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected on C.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.

-

-

-

... More
Centrifugal Monoblock Pump set (Double Stage)

-

-

-

... More
11.00 KW (15 HP)

2

197526

98763

... More
Providing and fixing at site with necessary packing, Horizontal Centrifugal Split Casting pumps with 4 pole induction motor operating at synchronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions. Note: Duty condition of required pump shall also be mentioned in BoQ.

-

-

-

... More
Discharge 20 to 30 LPS and head 41 to 50 M

-

-

-

... More
Supply & Fixing of electric controls feeder pannel comprising of suitable rating MCCB, fully automatic Star/Delta starter, overload relay, ampere meter with CTs, Volt meter, phase preventor, suitable starting capacitors, phase indicators, lighting arrangment etc complete suitable for three phase pump set. The pannel should have space for Energy meter (Supplied by DISCOM). All these equipments shall be housed by pannel box made out from 18 gauge MS sheet with powder coating. Pannel should be of minimum size 90X60X450mm with stand (made of angle iron of size 35X35X5mm) duly bolted/screwed with enclosure box having four legs, each leg lenght 18" and double door including inbuilt locking system. The legs should be embeded in M15 cement concrete platform. The size of CC plateform should be equal or bigger than the base size of pannel having height of atleast 200mm from ground level. The pannel should have opening of suitable size infront of space for energy meter with glass for meter reading. The operation of pannel should be suitable for on 440 Volts AC supply.

-

-

-

... More
Above 5.0 HP and up to 10 HP.

3

75576

25192

... More
Above 10.0 HP and up to 15 HP.

2

58408

29204

... More
Above 15 HP

2

66472

33236

... More
Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS:694:1990 or ammended upto date and conductor as per class 5 of IS:8130:1980 including making connections etc.

-

-

-

... More
3 core 4.0 Sq.mm

500

157000

314

... More
3 core 10.0 Sq.mm

90

48420

538

... More
Supply & Fixing XLPE insulated/PVC sheathed cable of 1.1 KV grade with aluminium condutor armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavtion of 30cmx75cm size trench, 25cm thick under layer of sand, second class bricks covering, refelling earth, compaction of earth, making necessary connection, testing etc as required of size.

-

-

-

... More
10.0 Sq.mm, 4 core

130

29900

230

... More
25.0 Sq.mm, 3.5 core

50

17150

343

... More
35.0 Sq.mm, 3.5 core

100

41500

415

... More
Providing and Lowering in tubewell ISI marked GI pipe "B" class as per IS:1239 or ammended upto date threaded & double flanged (welded) on both ends and two numbers 25X3mm flat welded on both ends between pipe & flange, rubber washer & Nut-bolts etc. complete in all respect.

-

-

-

... More
50 mm dia

422

278098

659

... More
80 mm dia

40

35960

899

... More
Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc for holding the riser pipe assembly of submersible pump set.

10

7270

727

... More
Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge.

-

-

-

... More
MS pipe specials up to 600mm dia (with minimum 5mm thickness sheet)

200

25800

129

... More
Construction of CWR

-

-

-

... More
Construction of RCC Clear Water Reservoirs of required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab, top roof slab and food grade epoxy paint to inner face of the container and slab, including refilling and disposing of surplus stuff , all labour and material charges, providing and fixing accessories such as M.S./Alluminium ladder/RCC Stairs inside and outside, manhole frame and cover, puddle collar, ventilators, satisfactory hydraulic test and water tightness test as per IS code and providing three coats of cement paints on all exposed surface of structure etc. complete in all respect as per design data, criteria, obligatory requirements and detailed specifications, scope of work and GA drawing. The job include painting the name of the scheme and other details on the reservoir and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work.

-

-

-

... More
Rates for RCC Partially Underground type Circular Flat Slab CWR, SBC 7T/sqm, seismic zone II.

-

-

-

... More
250 KL capacity

250000

1572500

6.29

... More
Construction of Pumphouse and Boundry wall

-

-

-

... More
Construction of Pump house of required size suitable for installation of maximum 4 no. monoblock pump sets as per approved GA drawing, scope of work and technical specification complete work in all respect.

-

-

-

... More
Switch Board Room of Size 5X6 Mtr.

30

608730

20291

... More
Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing, scope of work and technical specifications complete work in all respect.

140

846300

6045

... More
Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamal paints.

300

36600

122

... More
Construction of RCC Sluice valve chamber for different type of valves including earthwork excavation, 100mm PCC M15 as leveling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as directed by Engineer-in-Charge.

-

-

-

... More
For Class-AA loading

-

-

-

... More
Sluice valve chamber of size 1.26m x1.185m x1.88m for pipe size-from 200-to-300mm

2

108940

54470

... More
For in-campus Valve Chambers

-

-

-

... More
Sluice valve chamber of size1.13m x0.85m x1.225m for pipe size-upto100mm

2

59632

29816

... More
Sluice valve chamber of size1.17m x0.95m x1.37m for pipe size-from 125-to-150mm

2

67008

33504

... More
Operation of all civil, mechanical and electrical facilities of the system including wages to staff cost of consumables lubricants and spares, re-winding of burnt motors, repair of pipe line, valves etc and making good all major and minor faults and all repair / replacements as mention in the scope of work but excluding the cost of power charges for period of 10(Ten) years after 1 Year Defect liability period as per scope of work and direction of Engineer-In-Charge.

-

-

-

... More
After completion of sucessful work and Defect Liability period

-

-

-

... More
Operation and maintenance of scheme for 10 Years after one year DLP

1

4012000

4012000

... More
Design, construction, execution, testing and commissioning of Rapid Gravity filterTreatment Plant including all relevant civil, electrical , mechanical ,instrumentation, utomization and SCADA works and Stores along with ancillary civil works as defined in scope of work and direction of Engineer-In-Charge for the following sizes .

-

-

-

... More
1.00 MLD

1

3900000

3900000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.