Military Engineer Services Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date21 Oct 2024
Closing Date9 Nov 2024
Tender Amount₹ 45,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Removing Surplus Soil to a distance not exc 50.00 Metre away and depositing where directed at a level not exc 1.50 Metre above the Starting Point, etc complete all as specified and as directed by Engr-in-Charge.

289.03

-

-

... More
M & L Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180 mm thickness, etc complete all as specified and as directed by Engr-in-Charge. Note: For the purpose of Payment, Punned thickness of Sand Cushioning shall only be measured.

243

-

-

... More
Supply and laying un-reinforced precast conrete cable cover,class HVP,Type 1 with peak, size 300mm X 180 mm X 40 mm covering with width equal to length of cable cover as the mechanical protection to cable laid in trenches flat etc complete all as specified and as directed by Engr-in-Charge.

4445

-

-

... More
S & F Sub-Class ‘B’ Brick, well burnt, laid breadthwise along the length of Cable laid in trenches over Sand Cushion laid for UG Cable Protection, etc complete all as specified and as directed by Engr-in-Charge.

19.2

-

-

... More
M & L boaring holes horizontally under Road without damaging the surface of road (minimum 1.0 Mtr below the road surface with the help of GI tubing of any dia not exceed 80 mm bore for passing of UG cable etc complete all as specified and as directed by Engr-in-Charge. Note : GI pipe laid shall be measured seperately.

60

-

-

... More
Taking down/out unserviceable underground LT Cables of any Cross Sectional Area and Connections and joints including Pipes, Bricks, etc of any description laying in trenches or fixed with Walls/Poles, segreating serviceable Pipes, Cables etc and keep in safe custody for reuse, etc complete all as specified and as directed by Engr-in-Charge. Note : Earthwork will be measured and paid under appropriate Items.

5000

-

-

... More
Supply and laying in repair XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area, laid in trenches/ surface of Wall/in GI Pipe along with Pole for connection to OH Lines including Brass Cable Glands Mild Steel Flat Iron Clamps, etc. and testing etc complete all as specified and as directed by Engr-in-Charge of following sizes:-

-

-

-

... More
All as per Item No 10.00 above but size 4 core x 10 Sqmm

1000

-

-

... More
All as per Item No 10.00 above but size 4 core x 25 Sqmm

800

-

-

... More
All as per Item No 10.00 above but size 3.5 core x 35 Sqmm

700

-

-

... More
All as per Item No 10.00 above but size 3.5 core x 70 Sqmm

500

-

-

... More
All as per Item No 10.00 above but size 3.5 core x 120 Sqmm

500

-

-

... More
All as per Item No 10.00 above but size 3.5 core x 185 Sqmm

500

-

-

... More
M & L in repair 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, of size 16sqmm served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular all as specified and as directed by Engr-in-Charge.

1000

-

-

... More
M & L in repairs House service bracket (hook type complete with 3.0m long G.I. pipe 40mm dia Med. grade, two nos 90 degree bends. M.S. hook and stay or guy including Dismantling old house service brackets, any type all as specified and as directed by Engr-in-Charge. Note:- The rates include cutting holes in walls etc. of any description, grouting rag bolts or rag angle iron service bracket, and making good with cement mortar 1:3 including making good finishing to match the existing work and removing rubbish off MOD premises.

30

-

-

... More
M & L Cable jointing kit for 1100 Volts grade heavy duty cable straight through joint kit(heat shrink type) complete with jointing material and accessories suitable for 3.5/4 core underground conductor cables including testing etc complete all as specified and as directed by Engr-in-Charge of following sizes:-

-

-

-

... More
All as per Item No 13.00 above but size 25 sqmm to 50 sqmm

24

-

-

... More
All as per Item No 13.00 above but size 70 sqmm to 120 sqmm

18

-

-

... More
All as per Item No 13.00 above but size 150 sqmm to 185 sqmm

4

-

-

... More
All as per Item No 13.00 above but size 240 sqmm to 300 sqmm

2

-

-

... More
S & F Galvanised Iron Pipe light grade as in protection of UG Cable laid in trenches of following sizes etc complete all as specified and as directed by Engr-in-Charge. including taking out old unserviceable pipe. Note : Cost of Mild Steel Clamp, Nuts, Bolts and painting is deemed to be included in the Quoted Unit Rate.

-

-

-

... More
All as per Item No 14.00 above but size 50 mm dia

24

-

-

... More
All as per Item No 14.00 above but size 40 mm dia

30

-

-

... More
All as per Item No 14.00 above but size 80 mm dia

18

-

-

... More
Dismantling stay assembly complete with stay wire all as specified and as directeted by Engr-in-Charge.

12

-

-

... More
M & L Stay Assembly complete with Accessories as show in Electrical Plate No. 1 of MES Schedule Part-I, diameter of Stay Rod 20mm, size of Plate 230 x 230 x 6 mm etc complete all as specified and as directed by Engr-in-Charge. Note : Earthwork, Cement Concrete, Mild Steel Stay Clamps with Bolts, Nuts, Stay Strand, Loop Insulator etc. will be measured and paid under approprite Items.

12

-

-

... More
Dismantling of Cross arms of MS channel or angle section etc complete all as specified and as directed by Engr-in-Charge.

2

-

-

... More
M&L Cross-arms, Bracings, Supports, Clamps and Back Plates fabricated from Structural Steel Sections including Nuts, Bolts, Washer, welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated/ directed and inclusive of one coat of Aluminium Primer one Under Coat and One Finishing Coat of Aluminium Paint, etc complete all as specified and as directed by Engr-in-Charge.

2

-

-

... More
Dismantling of old unserviceable insulators any type & any size from pole (PCC/RCC/Steel ) all as specified and as directeted.

130

-

-

... More
S&F Insulator Pin type Porcelain, Vitreous, White, Brown or Green including one Galvanised Mild Steel Spindle, Two Galvanised Iron Washers and One Galvanised Iron Nut, 100mm Height, 65mm dia for 1100 Volt grade etc complete all as specified and as directed by Engr-in-Charge.

80

-

-

... More
S & F Shackle type, Porcelain, Vitreous, White or Brown Insulator of size 100mm height 115mm dia including Galvanised Mild Steel 31x5mm Strap, 14mm dia Insulator Bolts, Nuts, Washers, etc. for Working Pressure 1100 Volt, etc complete all as specified and as directed by Engr-in-Charge.

40

-

-

... More
S & F Loop Type Insulator Vitreous White, Brown or Green, large size with overall dimensions 90x65mm, clearance of hole 16mm dia, etc complete all as specified and as directed by Engr-in-Charge.

10

-

-

... More
Dismantling and taking down of old unserviceable ACSR conductors, AAC conductor from existing PCC/RCC/Steel poles all as specified and as directed.

5

-

-

... More
S & F Aluminium Conductor Steel Reinforced (ACSR) (sizes as ordered) with permissible Sags and providing Jumper, etc., fixing on Electric Poles and binding to Insulators with Aluminium Binding Wire as in OH Conductors including stringing, tightening, etc., etc complete all as specified and as directed by Engr-in-Charge. Note : Cost of Binding Wire is deemed to be included in the quoted Unit Rate.

5

-

-

... More
S & F in repair Vice type connectors consisting of two brass plates, and two steel bolts and nuts for 2 conductors of equal or unequal sizes, for non-tension connections including treatment of connector and ACSR conductor of sizes 4mm to 7mm dia with conducting jelly all as specified and as directed by Engr-in-Charge.

25

-

-

... More
Labour for Releasing ACSR Conductor of existing OH Lines by un-binding from Insulator of any description, re-fixing after stretching, re-stringing the Conductor, removing excess Sag, maintaining proper distance between Conductors as ordered, and binding to insulators with Aluminium Binding Wire etc complete all as specified and as directed by Engr-in-Charge. Note : Cost of Binding Wire is deemed to be included in the Quoted Unit Rate.

80

-

-

... More
Taking down old unserviceable Line Separator in repair and S & F in replacement new PVC/ Fibre Separator for LT Lines 1100 Volts OH Conductor 2 Wire system for horizontal spacing of Conductor, fixing with Nuts, Bolts, Washers, etc , etc complete all as specified and as directed by Engr-in-Charge.

30

-

-

... More
Taking down old unserviceable Line Separator in repair and S & F in replacement new S & F PVC/ Fibre Separator for LT Lines 1100 Volts OH Conductor 4 Wire system for horizontal spacing of Conductor, fixing with Nuts, Bolts, Washers, etc., etc complete all as specified and as directed by Engr-in-Charge.

50

-

-

... More
M & L in repair of Air termination, single pointed aluminium rod 12mm dia and 300mm long of any size and capacity, etc complete all as specified and as directed by Engr-in-Charge.

18

-

-

... More
M & L in repair of Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed by Engr-in-Charge including taking down old unserviceable of any size and capacity.

200

-

-

... More
M&L in repair for earthing complete with using copper plate 60×60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing leadthick, burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to copper strip 20 x 3mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I connected to OH conductor on pole/ Panel/ main switch board etc all as specified or indicated and testing on completion including provision galvanized strip protected by 40 mm bore, light grade pipe and watering pipe shall be 20 mm bore medium grade GI pipe including excavation & earth work, PCC pit with RCC cover, charcoal, salt, funnel, GI strip and protection pipe upto 7.5 mtr etc complete all as specified and as directed by Engr-in-Charge.

16

-

-

... More
M&L in repair for earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized strip 32 X 6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I connected to OH conductor on pole/ Panel/ main switch board etc all as specified or indicated and testing on completion including provision galvanized strip protected by 40 mm bore, light grade pipe and watering pipe shall be 20 mm bore medium grade GI pipe including excavation & earth work, PCC pit with RCC cover, charcoal, salt, funnel, GI strip and protection pipe upto 7.5 mtr etc complete all as specified and as directed by Engr-in-Charge.

24

-

-

... More
M & L in repair for earth continuity conductor or main Earthing lead Galvanised iron strip of size 32 x 6 mm fix to pole, wall or buried in ground or down GI pipe or any type indicated situation for loop earthing/ lighting conductor etc as required with saddles and fixing screws for roof conductors and down conductors above ground level etc complete all as specified and as directed by Engr-in-Charge.

100

-

-

... More
Taking down existing Aviation light from transmitter tower/ hangar / technical building/High Mast and any location and supply and fixing LED Integral avaition light comprising of aluminium housing with polycarbonate enclouser, 240V AC, 50Hz including all electrical connection as required at site complete all as specified and directed by Engr-in-Charge. Make:- Bajaj Cat No:-BGAV 302 LED or equivelent in Havells / Philips as approved by GE. Note - Any additional T&P required on site for fixing avaition light, shall be arranged by the contractor.

12

-

-

... More
M&L in repair for Flexible PVC insulated multicore FR PVC sheathed multistranded copper conductor cable of 2.5 Sqmm x 3 core for voltage grade up to 1100 V conforming to IS 694 : 2010 for connection of light fitting from junction box/distrubutor panel or from over head conductors to fitting etc complete all as specified and as directed by Engr-in-Charge.

300

-

-

... More
S& F in repair for Astronomical time switch (2 Module), 240 Volt AC 50 Hz, having feature for time programming for daily/ weekly , Pluse switching, reset feature, Manual override including making all electrical connection to make the timer functional as per time set for auto ON/OFF of street lights etc complete all as specified and as directed by Engr-in-Charge including taking out old u/s times switch. Make: L&T Cat No:-AUTS02AST00 or equivalent in Legrand/Schinder/Havells.

6

-

-

... More
Dismantling concrete poles/ struts, any size and transporting to contractor's store and stacking etc complete all as specified and as directed by Engr-in-Charge.

11

-

-

... More
M & L in repair for Prestressed concrete pole, 9.0 metres long, 102mm x 152mm at top and 102mm x 289mm at bottom, class 10 etc complete all as specified and as directed by Engr-in-Charge.

11

-

-

... More
M&L Cement Concrete 1:4:8 (40mm graded aggregate) as Lean Concrete in Foundation of Poles, Stay Assembly, etc., including Form-work (as/if required), etc complete all as specified and as directed by Engr-in-Charge.

0.32

-

-

... More
M&L Cement Concrete 1:3:6 (40mm graded aggregate) as in Foundation of Poles, Stays, etc. including Formwork (as/if required) etc complete all as specified and as directed by Engr-in-Charge.

5.86

-

-

... More
M&L Cement Concrete 1:2:4 (20mm graded aggregate) as in Coping of Poles, etc. and finishing the Concrete surfaces Fair and Even including necessary Formwork required at Site(s), etc complete all as specified and as directed by Engr-in-Charge.

0.63

-

-

... More
Cutting/ trimming of tree branches not exc 150mm girth touching/approaching the overhead lines conductors by manual labour using hack saw/axe or by cutter machine to clear the overhead line upto 3 metre on each side including disposal of trimmed branches 100 Metre away inside the station area & clearing site complete all as specified & directed by Engr-in-Charge. Note:-Distance between two poles shall be considered as single span.

100

-

-

... More
Total in Figures

-

-

-

... More
Quoted Amount in Words

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.