Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 40,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_686123_1Tender No
8800/24-25/57/04/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Repair of indoor type LT pannel board mounted on bldg wall of size aprox 2.0X0.80X0.220 mtrs and replacement of unserviceable switch/control gears and meters,selector switches,indicator lamps, Key type panel door lock etc including replacement of any damage wiring and extension of incomming and outgoing cables by opening of loops/making joints with same size cable and provisioning of cable lugs /thimbles as reqd including removing all dirt, dust, etc all as specified and directed compriseing the following :- (a) MCCB 100 A -01 Nos. (b) Indicator Lamp -01 set (c) Aluminium bus bar -01 set
(d) Single/Three phase Energy Meter- 05 to 7 Nos (e) MCB SPN/SP -05 to 7 Nos (f) Key type door lock - 8 to 12 Nos (g) Arclic PVC sheet for Energy meter -06 to 08 Nos. Note : (i) Necessary eqpt and safety measures reqd for load balancing arranged by the contractor without any extra cost. (ii) Cost of New aluminium/Copper thimbles, earth and neutral link, insulator, hylem sheet, any type of screws,door locks any type as per site reqmt change under the job deemed to be included in the quoted rate. (iii) MCCB, MCB,copper/aluminium bus bar, indicator lamp, PVC arclic sheet required for relacement shall be measured and paid serately in relevent item.
6
-
-
Dismantling and taking down old Unsv existing panel board incl disconnecting of main feeder, sub feeders, bus bars, energy meters & removing from site complete all as specified and as directed..
2
-
-
Supply, installation and testing of LT Panel in replacement, factory made powder coated wall mounting termoplastic polycarbonate insulated panel with IP 65 according to IEC 60 529, with protection class II , flame retardant, self extinguishing with glow wire test at 960C according to IEC 60695-2-11, Impact strength IK 08 (5 Joule) in accordance with DIN EN 50102. The panel is in accordance with IEC 61439-1&2 the OEM of board/panel shall submit a copy of type test report (ASTA certification by CPRI) of a board made out of polycarbonate thermoplastic panel in accordance with IEC 60439-1. the CPRI report shall have mention of following tests performed and passed out satisfactorily with : temperature rise,dielectric properties, short circuit withstand current -rated peak & short time withstand current and rated conditional short circuit current , Degree of protection clearance & creepage Distance, Mechanical operation, Effectives of protective circuits, Degree of protection (a) Metering panel size 980x1254x247mm incomer-160A 4P, 25KA MCCB-01 No, outgoing- 63 A, FP , 10 KA MCB-04 Nos with provision for (10-60A) Three phase Energy Meter-04Nos Copper busbar rating 250 A Make HENSEL, L&T, Legrand
1
-
-
Supply, installation and testing of LT Panel in replacement, factory made powder coated wall mounting termoplastic polycarbonate insulated panel with IP 65 according to IEC 60 529, with protection class II , flame retardant, self extinguishing with glow wire test at 960C according to IEC 60695-2-11, Impact strength IK 08 (5 Joule) in accordance with DIN EN 50102. The panel is in accordance with IEC 61439-1&2 the OEM of board/panel shall submit a copy of type test report (ASTA certification by CPRI) of a board made out of polycarbonate thermoplastic panel in accordance with IEC 60439-1. the CPRI report shall have mention of following tests performed and passed out satisfactorily with : temperature rise,dielectric properties, short circuit withstand current -rated peak & short time withstand current and rated conditional short circuit current , Degree of protection clearance & ceepage Distance, Mechanical operation, Effectives of protective circuits, Degree of protection (a) Metering panel size 680X1100X320mm incomer-125 A, 4P, 25KA MCCB-01 No, outgoing-32 A, DP ,10 KA MCB-06 Nos provision for Single phase Energy Meter-06 Nos Make HENSEL, L&T, Legrand
1
-
-
Supply and fix electronic meters temper proof LCD display with polycarbonate cover single phase 230 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH.
30
-
-
Supply and fix electronic meters temper proof LCD display with polycarbonate cover three phase 415 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH.
5
-
-
M&L for checking of earth resistance test of bldg connected with panel / distribution box by disconnecting of earth strip/ wire with the help of earth resistance tester complete and maintained records in register as per sample given all as specified and as directed . Note (i) Necessary eqpt , safety measures and stationary reqd for earth resistance test arranged by the contractor without any extra cost.
90
-
-
Taking out old LT under ground cable from trenches/floor/road/wall/pipe/pole of any size and description incl joint complete all as directed .
375
-
-
Excavation in trenches in soft loose soil not exceeding 1.5 m deep and not exceeding 1.5 m width and getting out including forming bottom surface for laying cables/pipes complete all a specified and directed
50.2
-
-
Returning, filling in, including spreading, watering and well ramming in layers n. exc 25 cm thick in any type of soil ( same as soft loose ) complete all as specified and as directed.
37.65
-
-
Removing of surplus excavated spoil not exceeding 50 M distance and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
12.55
-
-
Supply and laying un-reinforced precast concrete cable covers, factory made, class-LV, Type-1, flat, as per IS 5820, of size 300mmx 180mmx40mm laid dry complete all as specified and as directed.
900
-
-
M&L filling in trenches with fine sand cushioning for LT UG cable including compacting after filling complete all as specified and directed. Note : sand to be filled 23cm and carefully punned to 18 cm thickness. Punned thickness will be measured for the purpose of payment
10.25
-
-
M & L for GI pipe light grade of 50 mm bore with necessary fittings laying in treanches, floors, fixed to wall/poles all as reqd at site and complete all as specified and as directed.
45
-
-
Supply Laying and testing of LT XLPE insulated, PVC Sheathed, galvanized steel strip armoured electric power cable with stranded aluminium conductor, 1100 volts grade of size 50 Sqmm 3.5 core confirming to IS : 7098(Part-I), suitable for earthed system, laid in duct/trench/along pole/wall etc including nuts, bolts, washers, saddles and screw etc and making connection, complete all as specified and directed
70
-
-
All as per item no 18 but sec. area 70 sqmm 3 1/2 core.
65
-
-
All as per item no 18 but sec. area 35 sqmm 3 1/2 core.
125
-
-
All as per item no 18 but sec. area 25 sqmm 3 1/2 core.
115
-
-
M&L in replacement LED Type indicating Lamp for indication of RYB-01 Set
45
-
-
M&L in replacement Al bus bar rating 200 Amps including making hole suitable for panel with tape insulation of suitable colour in Phase RYB & neutral in Black colour complete all as specified and as directed .
15
-
-
M&L in replacement aluminium bus bar rating 250 Amps including making hole suitable for panel with tape insulation of suitable colour in Phase RYB & neutral in Black colour complete all as specified and as directed.
20
-
-
M&L in replacement Arclic PVC sheet minimum 4 mm thick with fixing arrangement in Panel box suitable for Meters fitted in panel complete all as specified and as directed .
5
-
-
M & L for preparation of old painted surface of electric panel box at any position by removing all dirt, dust, etc and painting complete surface including connected accessories with two coat of synthetic enamel paint of approved colour including writing of identification etc complete all as specified and directed.
40
-
-
Taking down old DB and Supply and fixing in repair flush in wall double door manufacturer double door MCB DB SPN 08 way comprising of sheet metal enclosure powder coated fitted with bus bar 200 Amps 240 volts complete all as specified and directed.
15
-
-
Taking down old DB and Supply and fixing in repair flush in wall double door manufacturer double door MCB DB SPN 12 way comprising of sheet metal enclosure powder coated fitted with bus bar 200 Amps 240 volts complete all as specified and directed.
12
-
-
Taking down old DB and Supply and fixing in repair flush in wall double door manufacturer double door MCB DB SPN 04 way comprising of sheet metal enclosure powder coated fitted with bus bar 200 Amps 240 volts complete all as specified and directed.
4
-
-
Taking down old DB and Supply and fixing in repair flush in wall double door manufacturer double door MCB DB TPN 04 way comprising of sheet metal enclosure powder coated fitted with bus bar 300 Amps 415 volts complete all as specified and directed.
52
-
-
Taking down old DB and Supply and fixing in repair flush in wall double door manufacturer double door MCCB DB VTPN 04 way comprising of sheet metal enclosure powder coated fitted with bus bar 400 Amps 415 volts complete all as specified and directed.
2
-
-
S&F MCB 240 volts SPN 40-63 amp 10KA breaking, capacity, ISI marked, complete all as specified and directed .
100
-
-
S&F MCB 240 volts SP 6- 32 amp 10 KA breaking capacity complete all as specified and directed.
300
-
-
S&F MCB TPN 415 volts 63 amp 4 pole 16 KA breaking capacity, ISI marked complete all as specified and directed.
75
-
-
S&F MCCB 415 volts 4 pole 100 amp 16 KA breaking capacity, ISI marked complete all as specified and directed.
5
-
-
S&F MCCB 415 volts 4 pole 125 to 160 amp 25 KA breaking capacity ISI marked complete all as specified and directed.
3
-
-
S&F sheet metal enclosure SPN 240 Volts having 2 pin and earth plug and socket complete with one single pole MCB 20 Amps all as specified and directed
40
-
-
Taking down old submain wiring and Supply and fixing for concealed/conduit sub main wiring with 2 single core 2.5 Sqmm copper conductor (Multistandered) in PVC FRLS conduit of suitable size as required, PVC FRLS board with all fittings one including 1.50 Sqmm copper conductor as earth continuity complete all as specified and directed. NOTE: Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
110
-
-
Taking down old submain wiring and Supply and fixing for concealed/conduit sub main wiring with 2 single core 4 Sqmm copper conductor (Multistandered) in PVC FRLS conduit of suitable size as required, PVC FRLS board with all fittings including one 2.50 Sqmm copper conductor as earth continuity complete all as specified and directed.
NOTE: Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
200
-
-
Taking down old submain wiring and Supply and fixing for concealed/conduit sub main wiring with 2 single core 6 Sqmm copper conductor (Multistandered) in PVC FRLS conduit of suitable size as required, PVC FRLS board with all fittings including one 4.0 Sqmm copper conductor as earth continuity complete all as specified and directed.
NOTE: Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
300
-
-
Taking down old submain wiring and Supply and fixing for concealed/conduit sub main wiring with 2 single core 10 Sqmm copper conductor (Multistandered) in PVC FRLS conduit of suitable size as required, with all fittings including one 6.0 Sqmm copper conductor as earth continuity complete all as specified and directed.
NOTE: Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
120
-
-
Taking down old submain wiring and Supply and fixing for concealed/conduit sub main wiring with 4 single core 10 Sqmm copper conductor (Multistandered) in concealed PVC FRLS conduit of suitable size as required, with all fittings including 2 single core 6.0 Sqmm copper conductor as earth continuity complete all as specified and directed. NOTE: Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
450
-
-
M&L for maintenance Free chemical earthing complete copper rod of not less than 32 mm dia, 3 meter long through suitable size bore including chemical back fill compound of 25 kg two bags with filling bottom to top complete as required with copper earth strip of size 20x3mm upto test point, PVC earthing pit cover complete all as specified and directed.
2
-
-
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanised earth lead wire 4.0 mm dia by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth wire protected by provision of GI light grade pipe 25 mm bore including provision of concrete pit made from PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 3 of SSR 2009 Part-I and connecting to Poles all as specified or indicated including testing on complete all as specified and as directed by Engineer-in-Charge.
25
-
-
Replacement of UNSV Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the GI earth strip 25x4 mm by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth wire protected by provision of GI light grade pipe 40 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 3 of SSR 2009 Part-I and connecting to LT Panel / DG Sets / Voltage Stabilizer / Building all as specified or indicated including testing on complete all as specified and as directed by Engineer-in-Charge.
5
-
-
Supply and fix IP 65/66 Thermoplastic Transparent polycarbonate PC- Grey colour (RAL 7035) Metering Box with multi level knockouts as well as from rear side also for cable entry only possible via flanges with transparents lid unprotected outdoor (UV resistance) with internally embedded gasket technology . The junction box shall fulfill the following standards IEC 60670-22: Particular requirements for connecting boxes and enclosures. IEC 60695-2-11: Glow wire tested at minimum 960 deg c , Impact Resistant : IK 08 (05 Joule) Halogen free in accordance with IEC 60754-2 size (600x600x170)mm Make: Hensel, ABB, Siemens
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%