Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 75,500Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_671410_2Bid Award Id
ViewTender No
84196/C/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M&L for 75 mm thick PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and directed by engineer-in-charge.
416
-
-
M&L for vitrified ceramiclight shade tiles 10mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 Sqm, as in floor etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including screed bed or bedding layer of 15mm thick in CM (1:6) complete all as specified and directed by engineer-in-charge.
372
-
-
M&L for vitrified ceramic tiles 10mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 Sqm, as in skirting over & including 10mm thick backing coat of CM (1:4) complete all as specified and directed by engineer-in-charge.
34
-
-
M&L for glazed ceramic tiles size 350x250x7mm /450x350x7 mm thick on vertical surfaces, set & joined in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over & including 10mm thick backing coat of CM (1:4) complete all as specified and directed by engineer-in-charge.
80
-
-
M&L for machine cut kota stone slab for flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including screed bed or bedding layer of 20 mm thick in CM (1:6) complete all as specified and directed by engineer-in-charge.
44
-
-
M&L 20-25mm thick Granite (of any type) work (table rubbed and polished) as in steps, jambs, pillars, window-cills, cooking platfoms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by engineer-in-charge.
38
-
-
M&L for 5cm sand stone slabs in sun shades, chajjas, shelves, cills, landings, cover stones, templates & similar works, etc. n exc. 2m in length, punched dressed on face and along exposed sedes, self faced on other side and set and pointed in cement mortar 1:4 complete all as specified and directed by engineer-in-charge.
46
-
-
M&L for 50mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection and surface finished even and smooth without using extra cement complete all as specified and directed by engineer-in-charge.
204
-
-
Dismantling of Stone slabs in roof, suspended floor, chajjas, landings etc of any description or thickness jointed in any mortar complete all as specified and directed by engineer-in-charge.
320
-
-
M&L for jodhpur stone roof slabs, self faced 7.5cm to 10cm thick, 25cm to 35cm wide, hoisted, set jointed and grouted 1:6 complete all as specified and directed by engineer-in-charge.
270
-
-
All as per serial item No. 13.00 here-in-above but except stones.
50
-
-
M&L for flush pointing single joints in brick work or masonry in detached work, flashings, etc on ceiling complete all as specified and directed by engineer-in-charge.
8
-
-
Complete removal of existing water proofing treatment incl bedding if any n exc. 40mm thick etc. on any type of roof, cleaning with wire brushers etc. and removal of debris out side MD land complete all as specified and directed by engineer-in-charge.
490
-
-
M&L for 40mm consolidated thickness PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate for levelling course all as per the requirements complete all as specified and directed by engineer-in-charge.
490
-
-
M&L for 10mm thick screed plaster on roof for laying in CM 1:4 water proofing treatment with using WPC complete all as specified and directed by engineer-in-charge.
Note:- WPC will be measured and paid separately under relevant item a
490
-
-
Supply only integral Waterproofing compound complete all as specified and directed by engineer-in-charge.
56.2
-
-
M&L for water proofing treatment with 3mm thick APP (Actatic poly propylene) modified membrane reinforced with non woven polyester mat of weight 150 gms/sqm as centre core & without multiple layers of polythylene applied by thermo fusion using LPG torch on the bottom portion of the membrane after applying a coat of bituminous primer @ 0.3 Ltr/Sqm over roof ( an overlap of 100mm & 150mm shall be provided on sides & end respectively) including a coat of bitumen grade 85/25@1.20 Kg/Sqm complete all as specified and directed by engineer-in-charge.
490
-
-
M&L for preparation of new surfaces APP membrane and applying one coat of aluminium paint on top of APP membrane to get uniform finish compound complete all as specified and directed by engineer-in-charge.
490
-
-
Taking down cement plaster on stone walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed by engineer-in-charge.
280
-
-
M&L for rendering 15mm thick on stone masonry surfaces in CM (1:6) finished the surface even and smooth without extra cement complete all as specified and directed by engineer-in-charge.
145
-
-
M&L for rendering 15mm thick on stone masonry surfaces or surface other than fair face of brickwork in CM (1:4), the surface even and smooth without extra cement complete all as specified and directed by engineer-in-charge.
75
-
-
M&L for rendering 5mm thick on surfaces of ceiling in CM (1:3) and finishing the surface even and smooth without using extra cement complete all as specified and directed by engineer-in-charge.
60
-
-
M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of alkali resistant primer including 2 mm thick of putty on wall complete all as specified and directed by engineer-in-charge.
145
-
-
M&L for preparation of new plastered surfaces and applying three coats of white wash on ceiling complete all as specified and directed by engineer-in-charge.
60
-
-
M&L for finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed by engineer-in-charge.
75
-
-
M&L for complete removal of existing treatment of old plastered surfaces of wall and applying finishing walls with Acrylic Smooth exterior paint of required shade (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed by engineer-in-charge.
370
-
-
M&L for complete removal of existing treatment of old plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer including 2 mm thick of putty on wall complete all as specified and directed by engineer-in-charge.
375
-
-
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n exc 1.50 sqm each and removing from site and making good disturbed surface of walls in cement mortar (1:3) complete all as specified and directed by engineer-in-charge.
33
-
-
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.50 sqm but not exc 4 Sqm each and removing from site and making good disturbed surface of walls in cement mortar (1:3) complete all as specified and directed by engineer-in-charge.
16
-
-
M&L for Joist, channel, angle, or tee sections, fixed independently, without connection plate, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) Fe 410-W (Gde E-250) quality 'A' complete all as specified and directed by engineer-in-charge.
461
-
-
S & F 2nd class HW 35mm thick, factory made, plain framed, paneled shutter (Two panels) with panels of 9mm thick BWP grade ply wood bonded with high quality liquid phenol formal dehyde synthetic resin adhesive conforming to IS-710. The size of rails & style shall be as per IS-1003 (part-I) kiln seasoned as per IS-1141 & chemically pressure treated as per IS-401 complete all as specified and directed by engineer-in-charge.
4.82
-
-
S & F for 2nd class HW 30 mm thick, glazed and skeleton shutters factory made open rebated and prepare to receive glass, gauge etc (with sash bar), edges of framing plain, chamfered or rounded, fitted with cut & mitred beads for securing glass etc. Size of members of shutter shall be as specified in SSR 2009 Part-I, section 8 clause Member shall be kiln seasoned as per IS-1141 & chemically pressure treated as per IS-401 complete all as specified and directed by engineer-in-charge.
4.8
-
-
S & F for 2nd class HW 35 mm thick, glazed and skeleton shutters factory made open rebated and prepare to receive glass, gauge etc (with sash bar), edges of framing plain, chamfered or rounded, fitted with cut & mitred beads for securing glass etc. Size of members of shutter shall be as specified in SSR 2009 Part-I, section 8 clause Member shall be kiln seasoned as per IS-1141 & chemically pressure treated as per IS-401 complete all as specified and directed by engineer-in-charge.
12.5
-
-
S&F factory made Box Type steel window with side hung shutters including projecting type hinges with steel handle, and steel peg stay , complete without glazing bars, dovetailed or complete as shown in Drawing No. CEJZ/TD/22 sheet 1/1 to 1/3 complete all as specified and directed by engineer-in-charge.
61
-
-
S&F Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con-foRming to Fe 290.Gde-E-165 complete all as specified and directed by engineer-in-charge.
433
-
-
S&F stainless steel wire cloth 0.36mm nominal dia of wire & average width of aperture 1.40mm & fixed with wire staples complete all as specified and directed by engineer-in-charge.
24
-
-
S&F 4.00 mm thick sheet glass, ordinary quality & glazing with oil putty not exc 0.50 Sqm each pane complete all as specified and directed by engineer-in-charge.
17
-
-
S&F mild steel butt hinges, medium weight, cold rolled, ISI marked of size 100 mm complete all as specified and directed by engineer-in-charge.
96
-
-
S&F aluminium, anodised, barrel tower bolt of extruded section, ISI marked, 150 mm long complete all as specified and directed by engineer-in-charge.
52
-
-
S & F extruded aluminium handle fabricated type, anodised 150mm size conforming to IS complete all as specified and directed by engineer-in-charge.
64
-
-
S & F 300mm long aluminium alloy,anodised, sliding door bolts with hasps, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed by engineer-in-charge.
17
-
-
S&F in repairs decorative type curtain rod, stainless steel, 25 mm dia with not less than 1mm wall thickness complete all as specified and directed by engineer-in-charge.
61
-
-
S&F in repair decorative type brackets , stainless steel, suitable for 25mm dia curtain rod complete all as specified and directed by engineer-in-charge.
80
-
-
M&L for preparation of new wooden surface over 10cm width or girth and applying two coats of synthetic enamel paint of Ist quality over a coat of pink primer complete all as specified and directed by engineer-in-charge.
45
-
-
M&L for preparation of new steel surface over 10cm width or grith & applying two coats of synthetic enamel paint of 1st quality over a coat of red oxide primer complete all as specified and directed by engineer-in-charge.
124
-
-
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards /slabs/ blankets, any thickness, including cover fillets complete all as specified and directed by engineer-in-charge.
349
-
-
M&L for anodised aluminium snap grid 605 x 605mm frame work for false ceiling and hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed by engineer-in-charge.
349
-
-
S&F 12mm thick gypsum board in ceiling fixed with screw as per manufacturers instructions complete all as specified and directed by engineer-in-charge.
349
-
-
E&M WORK
Taking down carefully point wiring of any type (i.e., on wooden batten, surface conduit, casing-N- capping or concealed conduit) complete for light, fan socket or power point with fittingS&Fixtures such as ceiling rose, electric fittings, holders, switches, sockets, regulators, wooden batten, conduit etc. including accessories such as wooden gutties/rawal plug, screw etc including making good disturbed surface to match the existing surface complete all as specified and directed by engineer-in-charge.
220
-
-
Taking down carefully MCB DB SPN/TPN of any type etc including making good disturbed surface to match the existing surface complete all as specified and directed by engineer-in-charge.
3
-
-
Taking down GI earthing complete all as specified and directed by engineer-in-charge.
3
-
-
M&L for point wiring with PVC unsheathed cable single core multistranded copper conductor 1.5 sq mm size, 1100 V grade, drawn into PVC casing & caping (ISI marked) not less than 20mm dia on surface with and including PVC unsheathed cable single core copper conductor 1.5 Sq mm as continuous earth wire and including pressed MS sheet sunk in box 1.12 mm thick with 2.8 mm thick laminated bakelite sheet all as specified & directed by Engr-in-charge for the following :-
-
-
-
One light/fan/Exhaust/Bell point controlled by one switch 5 Amp one way
140
-
-
Socket outlet 3 pin 5/6 ampsswitch socket outlet on same board
12
-
-
Socket outlet 3 pin 5/6 amps independent board
58
-
-
All as per item No.55.00 here-in-before but for one socket outlet/metal clad socket of 15 Amps fixed on independent board with 4.0 Sq mm multistranded copper conductor wire FRLS PVC insulated and 4.0 Sq mm copper conductor wire FRLS PVC insulated using as earth wire complete all as specified and directed.
10
-
-
S&F switch piano, flush type, single pole, one way 5 amps 230 Volts AC confirming to IS: 3854 and ISI marked complete all as specified and directed by engineer-in-charge.
230
-
-
S&F switch piano, flush type single pole, one way 15 amps 230 Volts AC confirming to IS: 3854 and ISI marked complete all as specified and directed by engineer-in-charge.
10
-
-
S&F switch sockets combination outlet multipurpose 2 pin, 5/6 Amps flush type ISI marked controlled by one switch 5 Amps complete all as specified and directed by engineer-in-charge.
70
-
-
S&F universal socket outlet with shutter 5/15 Amp flush type controlled by one switch 15 Amps complete all as specified and directed by engineer-in-charge.
10
-
-
S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd complete all as specified and directed by engineer-in-charge.
31
-
-
S&F Lamp holder PVC polycarbonate type with back plate suitable for battern fittings complete all as specified and directed by engineer-in-charge.
26
-
-
S&F Ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified and directed by engineer-in-charge.
96
-
-
S&F for sheet modular metal enclosure DB SPN 12 way made out of 1.5 mm thick sheet metal enclosure IP 43 with 200 Amps rated bus bar 240 volts double door with magnitic locking system complete all as specified and directed by engineer-in-charge.
3
-
-
S&F MCB SPN 240 volts, 40 Amps, 10 KA 'C' series fixing in DBs including connecting with bottle type copper thimble complete all as specified and directed by engineer-in-charge.
3
-
-
S&F MCB SP 240 volts, 6 to 32 Amps, 10 KA 'C' series fixing in DBs including connecting with bottle type copper thimble complete all as specified and directed by engineer-in-charge.
30
-
-
S&F LED lamp retro fit type 9 watts 230 Volt complete all as specified and directed by engineer-in-charge.
26
-
-
M&L for earthing complete with GI plate electrode 600x600x6mm thick burried directly and preferably vertically in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below ground level connected to GI earthing lead of 4mm dia GI steel wire all as shown in plate No 4 of SSR part (2009) to earthing test point including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete pit PCC (1:3:6) type C-1 (with 20mm graded aggregate). 50 mm thick precast RCC (1:2:4) cover slable (re-inforced with 8mm dia TMT bar @ 15 cm both ways and suitable handle made of 10mm dia ) including necessary earth work in excavation, returning filling, and removal of surplus earth upto a distance exceeding 50 mtr etc. all as shown in electric plate No 2 of SSR part-2 complete all as specified and directed by engineer-in-charge.
3
-
-
S&F LED light fitting 1x 20 watt, 220V, AC decorative box type with driver holder including LED tube light connecting up with three flexible copper conductor cable with suitable size from ceiling rose complete all as specified and directed by engineer-in-charge.
49
-
-
S&F road way light fitting with high power LED as light sources of capacity 20 watts IP 66 with suitable drivers etc fixing to wall/poll with including taking down old unserviceable street light fittings of any type and capacity complete all as specified and directed by engineer-in-charge.
16
-
-
S&F service bracket for street light fitting made out of 40mm GI pipe of suitable dia light grade not less tha 1.2 mtr long, bent to 115 degree shape, fixed to pole/ wall in any position with 2Nos 32x6mm GI clamp, nut, bolts, washers etc complete all as specified and directed by engineer-in-charge.
16
-
-
Evaluation Notes How It Works ?