Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 90,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_685336_1Tender No
8558/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://defproc.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Material and labour for clean dry tibba sand in trenches/ducts for cushoning to cable complete all as specified. (Punned thickness shall be measured & paid)
114
-
-
Supply and laying in repair stone patti 40-50 mm thick, 25-30 cm wide abutting each other for cable protection complete all as specified.
228
-
-
Laying only stone patti received serviceable during excavation for cable complete all as specified.
152
-
-
Labour for removing and taking out existing underground LT Cable 150 Sqmm 3.5 core from trenches or pole or underground in pipe duct either by cutting PCC surface and relaying, Jointing and testing the same cable and making good the disturbed surfaces upto entire satisfaction of Engr-in-charge, complete all as directed by Engineer-in-Charge.
Note: Quoted rate deemed to be inclusive of excavation wherever required.
100
-
-
Labour for removing and taking out existing underground LT Cable 120 Sqmm 3.5 core from trenches or pole or underground in pipe duct either by cutting PCC surface and relaying, Jointing and testing the same cable and making good the disturbed surfaces upto entire satisfaction of Engr-in-charge, complete all as directed by Engineer-in-Charge.
Note: Quoted rate deemed to be inclusive of excavation wherever required.
100
-
-
Supply & Laying, Jointing and testing in replacement 150 Sqmm 3.5 core underground armoured cable LT XLPE insulated cable 1100 Volts PVC bedded galvanised steel strip or wire armoured electric LT UG cable heavy duty with multi stranded aluminium conductor laid in trenches / walls/ ducts passing through pipe cable of following size complete all as specified:-
Note: Quoted rate deemed to be inclusive of excavation wherever required
660
-
-
Supply & Laying, Jointing and testing in replacement 120 Sqmm 3.5 core underground armoured cable LT XLPE insulated cable 1100 Volts PVC bedded galvanised steel strip or wire armoured electric LT UG cable heavy duty with multi stranded aluminium conductor laid in trenches / walls/ ducts passing through pipe cable of following size complete all as specified:-
Note: Quoted rate deemed to be inclusive of excavation wherever required
900
-
-
S&F in repairs 80mm bore galvanised steel tube "light grade" with fittings for protection of cable laid in tranches complete all as directed by Engineer-in-Charge.
30
-
-
S&F in repairs 40mm bore galvanised steel tube "light grade" with fittings for protection of cable laid in tranches complete all as directed by Engineer-in-Charge.
30
-
-
Supply and fixing in repairs of Aluminium lugs of size 50 sqmm to 70 Sqmm
25
-
-
Supply and fixing in repairs of Aluminium lugs of size 95 sqmm to 120 Sqmm
25
-
-
Supply and fixing in repairs of Aluminium lugs of size 150 Sqmm to 240 sqmm
25
-
-
S & F in repairs 70 to 120 sqmm 3.5 core end termination cable jointing kit, heat shrinkable for 1.1 KV grade XLPE cable complete with jointing material and accessories and testing after jointing complete all as specified and directed.
10
-
-
S & F in repairs 150 to 185 sqmm 3.5 core end termination cable jointing kit, heat shrinkable for 1.1 KV grade XLPE cable complete with jointing material and accessories and testing after jointing complete all as specified and directed.
6
-
-
S & F in repairs 70 to 120 sqmm 3.5 core Straight through cable jointing kit, heat shrinkable for 1.1 KV grade XLPE cable complete with jointing material and accessories and testing after jointing complete all as specified and directed.
10
-
-
S & F in repairs 150 to 185 sqmm 3.5 core Straight through cable jointing kit, heat shrinkable for 1.1 KV grade XLPE cable complete with jointing material and accessories and testing after jointing complete all as specified and directed.
6
-
-
M&L for drilling hole under road for laying of U/G cable through pipe of suitable size complete all as specified and directed at site.
40
-
-
M&L earthing complete as per electrical plate No. 3 of MES SSR Part-I with galvanised steel earth plate electrode 60cmx60cmx6.3 mm thick, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less then 1.5 metre below normal ground level connected to and including galvanised iron or steel earth wire 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 20 mm bore light grade and connected to continuous earth wire on pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cover complete all as specified & tested complete.
4
-
-
Note 1. Following items deemed to be included in quoted rates (a) Earth electrode (b) Main earth lead from earth electrode to test point and further to equipment to be earthed upto 7.5 mtr. ( c) M&L for connecting earth electrode and earth lead as specified (d) adequate qty of charcoal ,dust and commom salt as per direction (e) All labour involved incl testing of earth network (f) Excavation and earth work or drilling hole for electrode (G) PCC pit and CI Cover (h) Funnel with watering pipe, wiremesh and copper lugsetc. as specified (j) GI protection pipe of size as specified for protection of earth lead from mechanical injury or tempring Note 2. On testing after completion if the desired earth resistence is not obtained the earthing will be redone at no extra cost
-
-
-
M&L earthing complete as per electrical plate No. 3 of MES SSR Part-I with galvanised steel earth plate electrode 60cmx60cmx6.3mm thick, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less then 1.5 metre below normal ground level connected to and including galvanised iron or steel earth strip 25mmx4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 40 mm bore light grade and connected to continuous earth wire on pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cover complete all as specified & tested complete.
4
-
-
Note 1. Following items deemed to be included in quoted rates (a) Earth electrode (b) Main earth lead from earth electrode to test point and further to equipment to be earthed upto 7.5 mtr. ( c) M&L for connecting earth electrode and earth lead as specified (d) adequate qty of charcoal ,dust and commom salt as per direction (e) All labour involved incl testing of earth network (f) Excavation and earth work or drilling hole for electrode (G) PCC pit and CI Cover (h) Funnel with watering pipe, wiremesh and copper lugsetc. as specified (j) GI protection pipe of size as specified for protection of earth lead from mechanical injury or tempring.
Note 2. On testing after completion if the desired earth resistence is not obtained the earthing will be redone at no extra cost
-
-
-
S&F in repair earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc.as required to, GI wire 4mm
20
-
-
S&F in repairs earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc.as required to, 25x4 mm galvanised iron strip galvanised iron or steel wire
20
-
-
Supply & Fixing in repairs LT cable route indicator cast iron of suitable size mounted on 40 x 40 x 3 mm angle iron with height of 1.5 metre along with LT cable trench including planting in ground with PCC complete all as specified and directed.by Engr-in-Charge.
50
-
-
Material and labour in repairs for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as directed by Engr-in-Charge
20
-
-
M& L for Painting of LT panel with one coat of synthetic enamel paint of approved colour, writing letters on LT panel (by using appropriate colour, size /font stencil) for all incoming and outgoing feeder complete all as specified and directed by Engr-in-Charge
10
-
-
Material & Labour painting of all steel structures i.e channels angles complete 33 KV yard electrical system ,gantries channels , 2 pole structure bracket, 4 pole structures frame , steel plates angle of any size and length located inside 33 KV yard with and including with one under coat and one finishing coat with aluminum paint and also painting external surface of all power transformer, all outdoor VCB (33 and 11 KV), all outer OLTC and also writing of SM/MES No.after cleaning /preparation of surfaces including marking of pole No etc complete.
1
-
-
Material & Labour painting of steel tubular LT poles including cross arms, clamps etc in situ with one under coat and one finishing coat with aluminum paint after cleaning /preparation of surfaces including making yellow and black strips 30 cm wide 5 Nos with two coats of synthetic enamel paint etc complete.
400
-
-
Material & Labour painting of making yellow and black strips 30 cm wide 5 Nos with two coats of synthetic enamel paint on PCC LT poles including painting of cross arms, clamps etc in situ with one under coat and one finishing coat with aluminum paint after cleaning /preparation of surfaces.
3000
-
-
Material & Labour painting of making yellow and black strips 30 cm wide 5 Nos with two coats of synthetic enamel paint on PCC HT poles including painting of cross arms, clamps, etc in situ with one under coat and one finishing coat with aluminum paint after cleaning /preparation of surfaces.
30
-
-
Material & Labour painting of steel tubular HT poles including cross arms, clamps etc in situ with one under coat and one finishing coat with aluminum paint after cleaning /preparation of surfaces including making white and black strips 30 cm wide 5 Nos with two coats of synthetic enamel paint and marking of pole No , Feeder No also.
20
-
-
Material and Labour for marking on pole number of any type (HT/LT) with font size of 3 x 2.5 inch and specifiucation shown on LT/HT pole will be (T/A) for technical area and (D/A ) for domestic area with pole No. Complete all as specified and directed by Engineer-in-charge.
3450
-
-
Supply only Sodium Hypo chlorite solution (liquid chlorine) having 10% chlorine content in sealed HDPE container confirmed to IS code
9000
-
-
Supply only Poly Electrolyte (PE) in sealed bag confirmed to IS code
900
-
-
Supply only Poly Aluminium Chlorite (PAC) 10% content in sealed HDPE container confirmed to IS code
9000
-
-
M&L for Decarburising/servicing of STP main operating control panel by strip opening/disconnecting the electric supply, removing the dust deposits inside the panel and over the accessories by using blower, replace the burntout/unserviceable power contactor, auxillary contact block, MCB's, push button, indicator lamp, terminal block, burnt out internal wiring with suitable copper wire and copper lugs as per existing size matching the same existing colour code and number code, replacing the existing busbar with busbar (RYBN) of existing size and shape with colour code insulation as per practice, preparing the exterior steel surfaces of the panel including base frame and painting with two coats of synthetic synthetic enamel paint all as specified to the entire satisfaction of Engr-in-Charge. Note: Major spares like power contactor, auxillary contact block, MCB's shall measured and paid seperately under relevent items in this schedule, other minor spares like push button, indicator lamps,selector switches, terminal block, wires for internal wiring and busbar shall be deemed to be included in the rate quoted by contractor.
1
-
-
Supply only the following items for reparing of main operating control panel at STP:-
-
-
-
MCB 40A TP 'C' series
1
-
-
Power contactor 415V, 32A, integrated auxillary contacts as per existing size suitable for mounting in the existing din rail
1
-
-
Power contactor 415V, 20 KW, 27 HP with integrated auxillary contact block 415V, 3.6 A as per existing size suitable for mounting in the existing din rail
1
-
-
Power contactor 415V, 15 KW, 20 HP as per existing size suitable for mounting in the existing din rail
1
-
-
Power contactor 415V, 11 KW, 15 HP with integrated auxillary contact block 415V, 3.6 A as per existing size suitable for mounting in the existing din rail
1
-
-
Power contactor 415V, 7.5 KW, 10 HP with integrated auxillary contact block 415V, 3.6 A as per existing size suitable for mounting in the existing din rail
1
-
-
Power contactor 415V, 4 KW, 5 HP with integrated auxillary contact block 415V, 3.6 A as per existing size suitable for mounting in the existing din rail
1
-
-
Power contactor 415V, 23 KW, 31 HP with integrated auxillary contact block 415V, 3.6 A as per existing size suitable for mounting in the existing din rail
1
-
-
Supply and fix in replacement of sheet metal enclosure made of MS sheet 3.15mm thick dust proof outdoor type factory made size 45cmx30cmx15cm front openable with locking arrangement, incl painting with two coats of synthetic enamel paint over a coat of red oxide primer, providing opening for cable entry and exit. The enclosure should be fastening with stud bolts, nuts and washer over the wall etc with 12 way terminal block suitable for fixing 16 Sqmm aluminium cable, mounting accessory for terminal block complete including taking down old enclosure all as specified and directed by Engineer-in-Charge.
2
-
-
M&L for laying as in replacement of MS pipe 150mm bore medium grade for MBBR including cutting, welding and fabricating to match as per existing shape including necessary flange, bend, tee, reducer, including nuts, bolts, washers inclusive of one primer coat, two coat of synthetic enamel paint over the pipe all as directed by Engr-in-Charge
15
-
-
M&L for laying as in replacement of MS pipe 100mm bore medium grade for MBBR including cutting, welding and fabricating to match as per existing shape including necessary flange, bend, tee, reducer, including nuts, bolts, washers inclusive of one primer coat, two coat of synthetic enamel paint over the pipe all as directed by Engr-in-Charge
20
-
-
M&L for laying as in replacement of MS pipe 400mm bore medium grade for MBBR including cutting, welding and fabricating to match as per existing shape including necessary flange, bend, tee, reducer, including nuts, bolts, washers inclusive of one primer coat, two coat of synthetic enamel paint over the pipe all as directed by Engr-in-Charge
8
-
-
M&L for laying as in replacement of MS pipe 80mm bore medium grade for MBBR including cutting, welding and fabricating to match as per existing shape including necessary flange, bend, tee, reducer, including nuts, bolts, washers inclusive of one primer coat, two coat of synthetic enamel paint over the pipe all as directed by Engr-in-Charge
30
-
-
Cleaning of sewage MBBR Reactor, No-01&02 tube settler by using water jet spray machine to remove the sludge deposits on the interior surface of the reactor, in tube settler, in drain etc
1
-
-
Chemical analysis test (COD / BOD) for treated effluent from recognized / authorized testing laboratory as and when recommended by the Engineer - in- charge.
2
-
-
M & L for cleaning of sludge from drying beds & drains of STP by manual and removing sludge outside defence land covered with earth on top. Note: (i) All T&P for working at site shall be deemed to be included in the quoted rates (ii) The contractor is responsible for all safety of men employed by him during work at site.
400
-
-
M & L for rewinding of 3 phase electric non clog submersible motor of capacity 10 HP capacity with super enameled copper conductor of same guage weight and turns to achieve its full efficiency including tying the windings and connecting the coils and bringing the connections as that of exisitng complete including replacement of worn out/unserviceable bearings and water seal etc, re-conditioning of shaft by metal filling, grinding, finishing all as specified and directed by the Eng-in-Charge. Note: (i) The rate of transportation of pump motor from site to workshop and back is deemed to be included in the rate quoted by contactor. (ii) The rent of T&P for handling the pump motor assembly during dismantling, refixing, commissioning and testing is deemed to be included in the rate quoted by contatcor. (iii) The rate for disinfecting/chemical wash of the pump before opening the motor for repairing at workshop is deemed to be included in the rate quoted by contractor.
1
-
-
M & L for rewinding of 3 phase electric motor of capacity 3 HP capacity with super enameled copper conductor of same guage weight and turns to achieve its full efficiency including tying the windings and connecting the coils and bringing the connections as that of exisitng complete including replacement of worn out/unserviceable bearings and water seal etc, re-conditioning of shaft by metal filling, grinding, finishing all as specified and directed by the Eng-in-Charge. Note: (i) The rate of transportation of pump motor from site to workshop and back is deemed to be included in the rate quoted by contactor. (ii) The rent of T&P for handling the pump motor assembly during dismantling, refixing, commissioning and testing is deemed to be included in the rate quoted by contatcor. (iii) The rate for disinfecting/chemical wash of the pump before opening the motor for repairing at workshop is deemed to be included in the rate quoted by contractor.
2
-
-
M&L for Top up FAB (Fluidized aerated bed reactor) 20mm x 16mm media of Aeration 1 & Aeration 2 all as directed by Engr-in-Charge.
6
-
-
M&L as in replacement of air flow meter of capacity 72 to 225 Cubic Mtr/Hr for compressor all as directed by Engr-in-Charge.
1
-
-
Dismantling and taking out defective unserviceable butterfly valve and replacement with new butterfly valve 100 mm bore incl. jointing with MS nuts, bolts packing, minor adjustment complete all as specified and directed
4
-
-
Dismantling and taking out defective unserviceable butterfly valve and replacement with new butterfly valve 200 mm bore incl. jointing with MS nuts, bolts packing, minor adjustment complete all as specified and directed
2
-
-
Dismantling and taking out defective unserviceable butterfly valve and replacement with new butterfly valve 130 mm bore incl. jointing with MS nuts, bolts packing, minor adjustment complete all as specified and directed
10
-
-
Supply only DI (Ductile iron) specials such as bends, tees, collars, tail pieces, straight/angle connecting pieces any type (flanged ends, socketed ends or flanged/socketed ends) complete suitable for CI/DI mains of sizes 80 to 300 mm bore complete all as specified and directed.
80
-
-
M& L for repairing of tube settler with cement and block masonery work while installing MS pipe at the the end of tube settler for easy flow out of sludge. Note : Rates quoted including cleaning of sludge comes out while installing the pipes or butterfly valve.
3
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%