Military Engineer Services Tender

... More
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Civil And Construction
Eprocure
Opening Date11 Mar 2023
Closing Date31 May 2023
Tender Amount₹ 3,60,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Material and labour for concealed Point wiring for one light point/fan point /bell point controlled by one switch (using red, black and green etc colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box (Min 60mm deep, suitable size) concealed in wall, including 3mm thick bakelite plastic laminated sheet top cover for sunken boxes flush to surface for mounting of switches / socket / regulator etc, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. suitable for Modular fittings including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switches/ socket / regulator shall be measured and paid separately under appropriate item of BOQ/Sch 'A').

147

-

-

... More
All as per above Srl item No. 04 but for one socket out let 5 Amps point controlled by one switch (on same board) complete all as specified and as directed by Engineer-in-charge. (switches, sockets etc. shall be measured and paid separately under appropriate item of BOQ/Sch A).

21

-

-

... More
All as per above Srl item No. 04 but for one socket out let 5 Amps point controlled by one switch (on independent board and not below the any other switch board) complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ/Sch A).

37

-

-

... More
Material and labour for concealed Point wiring for one light point controlled by two Nos- two way switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box (Min 60mm deep, suitable size) concealed in wall, including 3mm thick bakelite plastic laminated sheet top cover for sunken boxes flush to surface for mounting of switches, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. suitable for Modular fittings including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switches shall be measured and paid separately under appropriate item of BOQ).

2

-

-

... More
Material and labour for concealed Point wiring for buzzer /bell point controlled by one switch (on same board) (using red, black and green etc colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box (Min 60mm deep, suitable size) concealed in wall, including 3mm thick bakelite plastic laminated sheet top cover for sunken boxes flush to surface for mounting of switches / socket / regulator etc, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. suitable for Modular fittings including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switches/ socket / regulator shall be measured and paid separately under appropriate item of BOQ/Sch 'A').

9

-

-

... More
Material and labour for concealed Point wiring for one socket out let 15/16 Amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 60mm deep, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. suitable for Modular fittings including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ).

39

-

-

... More
Material and labour for concealed Point wiring for one socket out let 15/16 Amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 4 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 25mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 60mm deep, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket, including provn of 4 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. suitable for Modular fittings including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ).

2

-

-

... More
Supply and hanging /fixing ceiling fan 1200 mm sweep AC Supply (Input Voltage Range ; 120 to 280V), BLDC type, 5 star rated, BEE and ISI Marked super enamelled, copper winding of 'B' class insulation, single phase, minimum 30W (± 10%), Temperature rise 40 degree maximum without remote with and including capacitive regulator, 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable size from ceiling rose to fan complete all as specified. Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account

24

-

-

... More
Supply and fixing Air Freshner fan, 250 mm sweep heavy plastic body, 240 volts complete with lovers shutters and mounted in suitable opening arrangement in wall and connecting up including three core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2mm drawn in flexible PVC conduit and fixed by using 4 Nos, 200 mm long 12 mm dia bolts nuts and washers and grouted in wall in CM(1:3), complete all as specified complete all as specified and as directed by Engineer-in-charge. Note :- (i) Serial Number as issued by Engr-In-Charge of fan and GE Office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account

11

-

-

... More
Supply and fixing exhaust fan (heavy duty) steel body, AC single Phase 230V, 50 Cycle per second, size 450mm sweep with blades and frame including self closing GI louvers off mode protection against birds etc mounted in suitable opening arrangement in wall and connecting up and including three core PVC Insulated PVC Sheathed copper conductor flexible cable 24/0.2mm drawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners 12mm dia 200mm long and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge. Note :- (i) Serial Number as issued by Engr-In-Charge of fan and GE Office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account

2

-

-

... More
Supply and fixing (concealed in wall or as directed) single pole and neutral sheet metal enclosure (AC Box) with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps, 240 volts, AC supply complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Supply and fixing (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 250 Amp rated bus bar) VTPN, 4 Way 415V, suitable for mounting MCCB/MCB, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-42 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge.

1

-

-

... More
Supply and fixing (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) TPN, 4 Way 415V, suitable for mounting MCB/Isolator etc, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge.

1

-

-

... More
Supply and fixing (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 12 Way 240V, suitable for mounting MCB/Isolator etc, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge.

5

-

-

... More
Supply and fixing MCCB of capacity 100 Amp, TPN, 415 volt, short circuit breaking capacity 16KA , fixed thermal magnetic trip, setting 80-100%, Icu-100% Ics confirming to IEC-947, IS-13947, including thimbles, nuts, bolts, washers etc, including making incoming, outgoing connections complete all as specified and as directed by Engineer-in-charge .

1

-

-

... More
Supply and fixing blanking plate suitable for any type of DB complete all as specified and as directed by Engineer-in-charge.

14

-

-

... More
Material and labour for concealed sub main wiring (using colour coding such as red, black, white, green colour or as directed) with 4 run of 16 Sqmm single core (05 run i.e 4 runs for main 3 phase and neutral, 01 run for continues as earth wire) FRLSH PVC insulated unsheathed multistrand copper conductor cable drawn through and including PVC conduit 25mm dia (medium quality ISI marked), for independent circuit including all fitting arrangement i.e. PVC clamp, rawl plug, screw, PVC junction box, tee, bend etc. and including cutting of chases in wall and making good disturbed surfaces of walls as per original complete all as specified and as directed. Note :- Five runs of copper conductor cable and one run of PVC conduit including accessories shall be measured and paid as one unit (one RM length) for payment and extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate.

50

-

-

... More
Material and labour for concealed sub main wiring (using colour coding such as red, black, white, green colour or as directed) with 2 run of 10 Sqmm single core (05 run i.e 4 runs for main 3 phase and neutral, 01 run for continues as earth wire) FRLSH PVC insulated unsheathed multistrand copper conductor cable drawn through and including PVC conduit 25mm dia (medium quality ISI marked), for independent circuit including all fitting arrangement i.e. PVC clamp, rawl plug, screw, PVC junction box, tee, bend etc. and including cutting of chases in wall and making good disturbed surfaces of walls as per original complete all as specified and as directed. Note :- Five runs of copper conductor cable and one run of PVC conduit including accessories shall be measured and paid as one unit (one RM length) for payment and extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate.

150

-

-

... More
Material and labour for concealed sub main wiring (using colour coding such as red, black, white, green colour or as directed) with 2 run of 6 Sqmm single core (03 run i.e 2 runs for main phase and neutral, 01 run for continues as earth wire) FRLSH PVC insulated unsheathed multistrand copper conductor cable drawn through and including PVC conduit 25mm dia (medium quality ISI marked), for independent circuit including all fitting arrangement i.e. PVC clamp, rawl plug, screw, PVC junction box, tee, bend etc. and including cutting of chases in wall and making good disturbed surfaces of walls as per original complete all as specified and as directed. Note :- Three runs of copper conductor cable and one run of PVC conduit including accessories shall be measured and paid as one unit (one RM length) for payment and extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate.

250

-

-

... More
Supply and fixing LED lamp minimum 3 star rated 9W LED B-22 base complete all as specified and directed by Engr-in-Charge with following specifications (a) Lumen system efficacy of lamp should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) CRI : More than 70

12

-

-

... More
Supply and fixing LED complete fitting including batten, T-8 Retro LED polycarbonate 1 x 20 Watt, appx 4 feet long, environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP-20. (g) CRCA pre coated housing with two coloured plastic end cap. (h) LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CCT : 6500K (m) CRI : Morethan 80 (n) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)

14

-

-

... More
Supply and fixing LED light fitting 1 x 10 Watt, appx 2 feet long environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Max 10%. (f) IP rating : IP-20. (g) CRCA pre coated housing with two coloured plastic end cap. (h) LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CCT : 6500K (m) CRI : More than 80 (n) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)

4

-

-

... More
Supply and fixing LED light fitting 1 x 15 Watt, round/square, ceiling surface type environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting and all accessories with following specifications and all as directed:- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP20. (g) CCT : 6500K (h) CRI : Morethan 80 (j) CRCA pre coated housing. (k) LED Driver of the make as of the luminaire. (l) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (m) Surge protection minimum 2.5 kV. (n) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)

22

-

-

... More
Supply and fixing LED light fitting 36 Watt , 2 ft X 2 ft , ceiling mounted type environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting and all accessories with following specifications and all as directed:- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP20. (g) CCT : 6500K (h) CRI : Morethan 80 (j) CRCA pre coated housing. (k) LED Driver of the make as of the luminaire. (l) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (m) Surge protection minimum 2.5 kV. (n) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)

33

-

-

... More
Supply, fixing and testing LED street light fitting of 35 Watt including LED lamps complete with body robust,corrosion resistant,superior finish and without any cracks or through holes,made in a single piece by high pressure die cast aluminium alloy including fixing on wall with 1.2 Mtr long GI pipe 32mm dia medium grade bracket at 120 degree angle with help of suitable GI clamps, nuts, bolts and washers etc complete all as directed.The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP -65 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 300 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distoration THD(I) less than 15% ,cool white colour and lamp starting time should not be more than 10 second. Fitting should be provided with 10 KV surge protection.Driver should be constant current constant voltage driver .Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection,no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degree Centrigrade to 50 degree Centrigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure IP 65 degree protection.Cover should not degrade due to heating and ageing.The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM-79 test report .

16

-

-

... More
Material and labour for concealed wiring for TV antenna connection complete with coaxial RG-6 heavy duty PVC insulated sheathed cable with copper conductor having single strand of 0.7 mm dia and a aluminium wire net drawn through and including PVC conduit 25mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (TV antenna connection socket outlet, terminal box shall be measured and paid separately under appropriate item of BOQ).

180

-

-

... More
Material and labour for Mild steel box/ modular metal flush box 1 module ,100mm x100mmx50mm box having holes for 20 mm conduit entry including 3 pin telephone socket outlet flush type duly marked with symbol of telephone and plastic laminated sheet cover / modular plate etc. complete for telephone connection and making good disturbed surfaces of walls by using CM (1:3) complete all as specified and as directed.

15

-

-

... More
Material and labour for concealed wiring for telephone connection complete with PVC insulated sheathed cable with copper conductor having single strand of 0.5 mm dia two pair taped for telephone wiring drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (Telephone connection socket outlet and terminal box shall be measured and paid separately under appropriate item of BOQ).

250

-

-

... More
Material and labour for GI box flush mounted 100mm x100mmx50mm having holes for 20 mm conduit entry including 2 pin TV socket outlet flush type duly marked with symbol of TV and 3 mm thick plastic laminated sheet cover/ Modular plate complete for telephone connection socket outlet flush type duly marked with symbol of telephone and making good disturbed surfaces of walls by using CM (1:3) complete all as specified and as directed.

7

-

-

... More
Subtotal

-

-

-

... More
Lump sum price worked out by the tenderer for “INTERNAL WATER SUPPLY WORKS" as listed in Schedule ‘A’ Section - III (Part-I)

1

-

30261.12

... More
Sch 'A' Sec - III (Part-II), (INTERNAL WATER SUPPLY WORKS)

-

-

-

... More
Supply and fixing hand shower (health faucet) fancy type, CP including 1 meter long 8mm dia flexible SS tube and including wall hook and fixing material complete all as specified and as directed by Engineer-in-charge.

4

-

-

... More
Supply and fixing toilet paper holder chromium plated complete all as specified and as directed by Engineer-in-charge.

4

-

-

... More
Supply and fixing 15mm bore two-way angle cock with flange chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed for iron pipe or for unions complete all as specified and as directed by Engineer-in-charge.

4

-

-

... More
Supply and fixing 15mm bore central hole basin mixer chromium plated for WHB complete all as specified and as directed by Engineer-in-charge.

2

-

-

... More
Supply and fixing glass shelf 500x125mm (with brass brackets) complete all as specified and as directed by Engineer-in-charge.

4

-

-

... More
Supply and fixing 15mm bore CP wall mixer with L bend (provision for over head shower) complete all as specified and as directed by Engineer-in-charge.

2

-

-

... More
Supply and fixing corner glass shelf 300 mm (with brass brackets) complete all as specified and as directed by Engineer-in-charge.

2

-

-

... More
Supply and fixing CP soap dish fixed with chromium plated screw complete all as specified and as directed by Engineer-in-charge.

4

-

-

... More
Supply and fixing CP towel rack with chromium plated screw complete all as specified and as directed by Engineer-in-charge.

2

-

-

... More
Subtotal

-

-

-

... More
Lump sum price worked out by the tenderer for “HARD STANDING WORK" as listed in Schedule ‘A’ Section -IV (Part-I)

1

-

147309.4

... More
Sch 'A' Sec - IV (Part-II), “HARD STANDING WORK"

-

-

-

... More
Supply and laying/fixing 60 mm thick (M35 grade) precast interlocking tile/paving block factory casted (made by using PVC/ Rubber moulds on Vibrating Table Machine) using grey cement and pigment, prepolished & preglazed, shape haxagon / trigular / zigzag / I-shaped etc, as directed, confirming to relevant IS, having compressive strength not less than 350 Kg/ Sqcm, laid over and including 25mm thick layer of sand cushining and filling the interstices etc with sand complete all as specified and as directed.

230

-

-

... More
Lump sum price worked out by the tenderer for “ROAD WORK" as listed in Schedule ‘A’ Section -V (Part-I)

1

-

1291927.49

... More
Sch 'A' Sec - V (Part-II), (ROAD WORK)

-

-

-

... More
Material and labour for 150mm thick WMM in two layers of 75mm each (compacted thickness) Wet mix macadam manufactured in WMM plant., with crushed stone aggregates specified grading 2 (63mm to 40mm size or of grading 3 (50 to 20mm size), spreading using sensor paver and consolidated to reqd gradient and camber complete all as specified and directed.

167.3

-

-

... More
M&L for continous Jodhpur stone Slab edging 7.5cm to 10cm thick 30 cm wide ((for depth of edging) and 35 to 45 cm long minimum, laid dry vertically jointing and pointing in CM 1:4, each stone slab self faced on both the vertical sides, edges slightly true and square on top edge hammer dressed for full thickness so that the depression from straight edge held the surface shall not exceed 20mm between two slabs including excavation and embedding to depth required and temping ground around stone edging, returning filling and disposal of surplus soil to a distance not exceeding 50m, complete all as specified and as directed.

565

-

-

... More
Material and labour for Thermo plastic paint road marking 2mm thick painting (lines, dashes, arrows, letters etc) with road safety spikeries glass beads @ 8% by weight including preparation of new or previously treated road surfaces and applying paint by using special applicator machine with heating arrangement complete all as specified and as directed.

60

-

-

... More
Supplying and fixing Delineator with twin reflector made out of MS 51 mm and mounted on oval shape in matel plate of dimension 302 mm x 167mm fitted with 02 Nos 100mm dia high reflective reflectors on both sides alon with 02 Nos 70mm x 23mm rectangular reflectors on each side for excellent reflective inthe night hour, alloy powder coated and rust resistant height of delineator 1000mm complete including taking out old broken delineator. complete all as specified and as directed by Enginreer-In-Charge.

20

-

-

... More
Subtotal

-

-

-

... More
Lump sum price worked out by the tenderer for “AREA DRAINAGE WORK)" as listed in Schedule ‘A’ Section -VI

1

-

95893.62

... More
Lump sum price worked out by the tenderer for “SEWAGE DISPOSAL WORK" as listed in Schedule ‘A’ Section - VII (Part-I)

1

-

74120.19

... More
Sch 'A' Sec - VII (Part-II), (SEWAGE DISPOSAL WORK)

-

-

-

... More
Construction of RCC manhole of depth 8.00m and 1.80m dia complete all as specified and as shown on drawings.

2

-

-

... More
Provn of Septic tank for 50 users complete all as specified and as shown on drawings.

1

-

-

... More
Provn of soakage well for 50 users complete all as specified and as shown on drawings.

1

-

-

... More
Subtotal

-

-

-

... More
Lump sum price worked out by the tenderer for “SECURITY FENCING AND GATE WORKS" as listed in Schedule ‘A’ Section - VIII

1

-

488243.12

... More
Lump sum price worked out by the tenderer for “EXTERNAL WATER SUPPLY WORKS" as listed in Schedule ‘A’ Section - IX (Part-I)

1

-

236980.32

... More
Sch 'A' Sec - IX (Part-II), (EXTERNAL WATER SUPPLY WORKS)

-

-

-

... More
Material and labour for DI pipe cutting upto 150 mm dia for reducing to required length for insertion of new branches, tees, collar, tail pieces etc in position complete all as specified. NOTE:- Necessary earth work, fitting/lead joints etc reqd to complete the job deemed to be included in the quoted rate.

1

-

-

... More
Supply and fixing cast iron sluice valve 80 mm dia with flanged ends class I PN 1.0 (heavy duty ISI marked) confirming to IS:14846-2000, drilled type, steel spindle, CI gate with brass ring, iron wheel handle, suitable for DI pipe line, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed.

2

-

-

... More
Material and labour for Construction of brick masonary valve pit chamber size 120 X120 X120 cm (internal dimension) using sub class 'B' bricks complete including demolition of exisitng valve pit , excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC (1:5:10) type E-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 10 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embeded portion of MS work duly applying black bitumenous paint before embeded complete all as specified and as directed.

1

-

-

... More
Material and labour for below road surface/hard standing suitable for inserting upto 200 mm dia pipe including removal of surplus soil and making good disturbed surface all as directed.

12

-

-

... More
Subtotal

-

-

-

... More
Lump sum price worked out by the tenderer for “EXTERNAL ELECTRIFICATION, STANDBY POWER DG SET AND LIGHTNING PROTECTION WORKS" as listed in Schedule ‘A’ Section - X (Part-I)

1

-

775923.01

... More
Sch 'A' Sec - X (Part-II), (EXTERNAL ELECTRIFICATION, STANDBY POWER DG SET AND LIGHTNING PROTECTION WORKS)

-

-

-

... More
M&L for dry sand (Local Tibba sand) and punning for cushioning and cover for protection of under ground electric cable complete all as specified and as directed. Notes : (i) Approved local Tibba dry sand free from vegetations, grass and other deleterious substances shall be used. (ii) For the purpose of payment, only punned thickness shall be measured.

30

-

-

... More
Supplying, installing, commission and testing diesel Generating Set 160 KVA capacity mounted acoustic weather proof as per CPCB (central pollution control pollution control Board) norms and noise level shall not exceed 75 bd at distenace of 1 Mtr and comprisiong of the following (Diesel Engine :- Diesel Egine developing not less than at NTP, 1500 RPM truvo charge water cooled ergine inclusie of the following standard accessrories :- (i) Radiator Cooling system (ii) Dircet coupled (iii) Flywheel to uit flexible coupling (v) Fuel housed (vi) Air eleaner (vii) Fuel and lub oil filter (viii) By pass filter (ix) Coolant inhabit (x) Fuel pump PTR type / in line mono block fuel injection pump (xi) Water pump (xii) Oil pump (xiii) Electric starter 24 volts DC (xiv) Industrial silencer (xv) Control push pull (xvi) Lub oil cooler (B) Alternator :- Alternator suitable for continous operation generationg 160 KVA at 1500 RPM 415 volrs at NTP 0.8 power factor 3 phase 50 Hz, self-excited & regulated with ball/rooler bearings confroming to IS-4722. (c) Fuel tank as recommended by manufacturer with inlet and outlet connection and fuel level indicator. (D) Base frame faricated form MS channel of suitable size and machined to ensure perfect alignment.

1

-

-

... More
(E) Two Nos. battery of 12 volts each of 180 AH lead acid type. (F) supply, installation, testing and commissioning of AMF (automatic Main Failure) panel suitable for generating set for capacity 180 KVA grounted in floor withPCC/RCC foundation factory made "indoor cubical type" front operation able fabricated from CRCA sheet (3.15mm) of suitable size comprising power contractors as per manufacturer recommendation (operating coil voltage 420 volt) or equivalent capacity of other makes bus chamber copper bus bar of current rating Amps with high insulation & instantaneous tripping device suitable for complete panel over current 0.5 Amps, electronic current with tripping indication of eac shape of fault and provisions of reset facilities completed protection of AMF panel, painted with powder coating of following features :- (i) 3 Phase MVR relay unit for main power contractor but with single phase protection both on in/out side, 3 phase low voltage cut off at 350 volts reverse phase protection 3 phase high voltage cut off 460 volts unbalance voltage tripping separate indication, lights for each tripping and 3 phase mains of front panel having 2 nos/ NC 6 Amps interlocking auxiliary contacts :- 01 no. Make puneet/PIC. (ii) 3 Phase AVR relay unit for generator supply contractor with same specifications as above. 01 No Make : Puneet/PIC (iii) Self dquential starting relay unit 24 volt DC with dual intertimer for self on, self off (3 sec to 15 sec) adjacent independently with another timer for set fails to start alarm with self power contractor 24 volts DC 25 Amps-01 No. (Make : Puneet/PIC) (iv) Electronic timer 220 volts 50 Hz on relay (10 sec to 40 sec) adjacent to restore commercial supply from main power contractor with 1 No./ NC auxiliary contract 6 Amps, 18 volts, 500 ohms-01 no (Make : L&T/SIEMENS/C&S

-

-

-

... More
(v) Off relay for fuel cut off operation for solenoid valve with fuel power contractor 24 volt DC, 25 Amps -01 No (Make : L&T/SIEMENS/C&S) (vi) Battery charging unit 24 volt 10 Amps consisting of step down/transformer with primary tap selector, bridge rectifier along with shhunt capacitor having digital battery voltmeter (0-30) volts of 3.5 digit LED/LCD/FND display panel mounting type also featuring track/boost & off facility-01 Set (vii) Digital voltmeter 0-500 volts mains operated having 3.5 digit LED/LCD/FND display panel mounting type along with volmeter selector withch for measuring volt meter-01 Set. (Make: AE/L&T/IMP/MECO) (viii) Digital ampere meter 0 to 300 Amps external CT operated having 3.5 digit LED/LCD/FND display panel mounting type along with 3 Nos. CTs of rating 300/05 and selector switch - 01 Set (Make : AE/L&T/IMP/MECO) (ix) 3 phase electonic energy meter for measuing, units for generator supply- 01 Nos (x) Digital 4 digit frequency meter (30-70) Hz having LED/LCD/FND display panel mounting mains operated - 01 No (Make : AE/L&T/IMP/MECO (xi) MCCB, 4 Pole, 250 A, 35/36 KA with adjustable over load & adjustable short circuit. Makes : Engine: Crompron Greaves,Mahindra & Mahindra, Ruston, Cummins, Kirloskar oils engines Ashok leyland CA Terppilar Alternator : Bharat Bijli, Crompton Greaves, Imens, Kirloskar Electric. Stamford, Catler Pillar, Mtu Volvo, Leroy Somer, Jyoti (for FLT Hanger) Note:- (a) All arrangement for pre-commissioning test shall be made by contractor with in overall cost quoted. (b) Pre commissioning test shall be carried out by rep of accepting officer. Test shall be carried out for duration of 12hrs.

-

-

-

... More
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing wire of size 4 mm dia by means of GI bolts/nuts/washers and protected by 15 mm bore GI light grade pipe upto test point or upto main switch board, HT/LT equipments, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.

7

-

-

... More
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing strip 32x6mm by means of GI bolts/nuts/washers and protected by 40 mm bore GI light grade pipe upto test point or upto main switch board / electric equipment / pole / lightning arrestor / HT/LT equipments / GODO switch /DG Set/ Transformer etc, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing strip upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.

30

-

-

... More
Material and labour for Brackets made out of GI tubing light grade 32mm dia, 1.2 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 50x3 mm for fixing of bracket for street light on steel tubular /PCC poles with suitable nuts and bolts including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.

10

-

-

... More
Supply and fixing Thermoplastic (polystreen) juction box haviing IP 65 protection of size 200 x 160 x 98mm fixed to pole with MS strip nuts bolts, having provision of 3 phase aluminium bus bar and MCB 1 to 6 AMP SPN, complete all as specified and as directed.

10

-

-

... More
Supply, installing, commissioning & testing Energy Efficient type (Level-II) transformer step down 11/0.433 KV as per IS 1180-2014 Level-2), copper wound outdoor type AC, 3ph, 4 wire 50 Hz filtered & Dehydratd tranformer oil and standard fittings/acccesories of capacity 160 KVA naturally cooled with external cooling tubes, core type delta connected on primary (HV side) and star connected on secondary (LV side) having taping range + 7.5% in steps of 2.5 % each with vector group Dyn -11 to be varied by a manually operated off load tap changing gear including first filling of oil, all fitting and accessories and mounting all as specified. The transformer shall have HT bushing on high voltage side and LT bushing and LT cable end box on low voltage side with neutral brough out side for earth connection and installed on PCC plat form as per manufacturer recommanded and all as specified and directed with following fitting and accessories :- (i) Name, Rating & Diagram Plant. (ii) On Load Tap Changer (OLTC) (iii) Earthing Terminal (iv) Lifting Eye Bolts (v) Air Release Plug (vi) Window for Tap Number (vii) Oil Drain cum Filtering valve with plug (viii) Oil filling cum filtering valve with plug (ix) Conservator with oil filling hole with cap (x) Silicagel Breather (xi) Removable manual crank handle to operate OLTC (xii) Removable inspection opening with cover (xiii) Oil Surege Relay Note Cost of -PCC foundation of size 2.5 M X 2.5 m x1.2 m as per Manfacturers recommendation shall bedemmed to be included in item rate.

1

-

-

... More
Supply, install, testing and commissioning LT Panel, outdoor type, cubical type made out of CRCA sheet 3.15 mm thick dust and vermin proof and angle iron of size 40 mm x40 mm x 6 mm, pedestal frame grouted in PCC (1:2:4) type B-1 20 mm graded crushed stone aggregates, thimbles, cable entry boxes with cable glands of cast copper alloys. Panel should covered from all sides with front and back lockable door and hinges complete with alumiuim bus bar of capacity 400 Amps, TPN, three phase, 04 wires (in sperate chamber) including painting with two coats of epoxy powder coating paint over a coat of red oxide primer and consisiting of the following :- (A) Main incoming;- (i) MCCB conforming to IS:13947 (Part-II), IEC-947, 4 pole, 250 Amps, 433 volts, 50 Hz, rupturing capacity 36 KA, with adjustable thermal and fixed magnetic setting - 01 No. (ii) Digital Voltmeter with built in selector switch 0-500 volts -1 No (iii) Digital Ampmeter with built in selector switch 0-250 Amps with Suitable CTs -1 No (iv) LED indicating lamps for RYB indication, Main ON, Standby Supply ON (5 lamps) - 01 Set (B) Main Outgoing;- (i) MCCB conforming to IS:13947 (Part-II), IEC-947, 4 pole, 100 Amps, 433 volts, 50 Hz, rupturing capacity 25 KA, with adjustable thermal and fixed magnetic setting - 01 No ( for AC Plant) (ii) MCCB conforming to IS:13947 (Part-II), IEC-947, 4 pole, 63 Amps, 433 volts, 50 Hz, rupturing capacity 25 KA, with adjustable thermal and fixed magnetic setting - 02 No ( for Bldg) (iii) MCB TPN 4 pole, 25 Amps, 10 kA, C Curve - 04 Nos (for Pumps) (iv) Nature Switch and 10/16 amp single pole MCB enclosed, IP 54- 01 Nos Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication.

1

-

-

... More
Material and labour for Construction of brick masonary valve pit chamber size 120 X120 X120 cm (internal dimension) using sub class 'B' bricks complete including demolition of exisitng valve pit , excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC (1:5:10) type E-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 10 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embeded portion of MS work duly applying black bitumenous paint before embeded complete all as specified and as directed.

1

-

-

... More
Subtotal

-

-

-

... More
Sch 'A' Sec - XI (Part-II), (SUMMER APPLIANCES AND HOT WATER SUPPLY WORKS)

-

-

-

... More
Supply & fixing electric water heater, storage type ABS body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and as directed and shown on drawings.

2

-

-

... More
Supply & installing of Voltage stabilizer for automatic operation having input & output voltage, Amps, Over & low voltage cutout and timer delay function etc digital display single phase naturally air cooled indoor type & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA with wall mounting bracket complete all as specified and as directed. Make : V-Guard, Model- VG100 or Equivalent Model ol Sinetrac / AE

1

-

-

... More
Supply, installing, commissioning and testing frost free refrigerator electric driven single phase 220 volts, AC 50 Hz,of capacity 310 ltrs with BEE approved, minimum 5 star rating double door, stablizer free operation, complete all as specified and as directed. Make : Sumsung, Model : RT37A4513BX/HL or equivalent Model of LG / Godrej Note : Contractor shall submit original purhase voucher and Warranty card as remmended by manufacturer.

2

-

-

... More
Supply & installing of Voltage stabilizer for automatic operation having input & output voltage, Amps, Over & low voltage cutout and timer delay function etc digital display single phase naturally air cooled indoor type & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1 KVA with wall mounting bracket complete all as specified and as directed. Make : V-Guard, Model- VG100 or Equivalent Model ol Sinetrac / AE

2

-

-

... More
Supply, installing, commissioning and testing Water Cooler fully stainless steel, electric driven single phase having approx storage capacity of 120 Ltr and nominal cooling capacity of 60 Ltr per hour with inlet PVC connection pipe of size 15 mm dia and 600 mm long of good quality complete with both ends CP nuts including electric connection through Voltage stablizer complete all as specified and as directed.

1

-

-

... More
Subtotal

-

-

-

... More
Lump sum price worked out by the tenderer for “RETAING WALL" as listed in Schedule ‘A’ Section - XII (Part-I)

1

-

6963784.41

... More
Sch 'A' Sec - XII (Part-II), (RETAING WALL)

-

-

-

... More
M&L for water proofing in concrete surface of retaining wall with 1.5mm thick self adhesive wwater proofing membrane topped with HDPE valeron film DR FIXIT SAMSHIELD X L1500 confirming to requirement of DIN EN 1849-1 for thickness with puncture ressistance of 220kn as per ASTM E 154 including cleaning the surface priming the surface with cold applied bitumenious primer properly sealing & 100mm overlap on end of membrane over the slab and wall including fixing protection board 8mm HDEP Dimple board spot bonded on retaining wall and roof before back filling from the three side of structure complete all as specified and directed by Engr-in-Charge

525

-

-

... More
M&L for anodisied aluminium grill (anodised transparent or dyed to required shade according to IS : 1868 with minium anodic coating of grade AC 15) of apporved design/pattern, with apporved standard section and fixed to the existing window frame with C.P brass/stainless steel screws @ 200 mm centre to centre, including cuttting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete all as specified and directed by Engr-in-Charge

24

-

-

... More
Subtotal

-

-

-

... More
Lump sum price worked out by the tenderer for “EXCAVATION, EARTHWORK AND SITE DEVELOPMENT WORK" as listed in Schedule ‘A’ Section - XIII

1

-

2463392.62

... More
Lump sum price worked out by the tenderer for “DISMANTLING AND DEMOLITION WORK" as listed in Schedule ‘A’ Section - XIV

1

-

15266.57

... More
Sch 'A' Sec - XV (CENTRAL AIR CONDITIONING SYSTEM)

-

-

-

... More
Supply installation , testing & commissioning of scroll type modular water cooled heat pump with cooling capacity of Min. 12.5 TR ( Actual ) and heating capacity of Min. 45 kW at below mentioned condition.( 2x12.5TR working +1x12.5TR standby ) There will be 03 Similar scroll type modular water cooled heat pump two will be working and one unit as Standby ) -Design conditions for Cooling: (a) Chilled Water Outlet Temperature : 7.0 deg C. (b) Condenser Water Inlet: 31.1 deg C. (c) Evaporator water flow (User Side): 76 USGPM (d)Condenser water flow(Heat Source Side): 96 USGPM (e)Pressure Drop on Evaporator & Condenser : 5.0 meter maximum (f)Minimum COP: 4.3 - Design conditions for Heating: (a) Hot water Out : 45 deg C. (b) Evaporator Water Inlet: 12 deg C. (c) Evaporator water flow (Heat Source Side): 96 USGPM (d) Condenser water flow(User Side): 76 USGPM (e) Pressure Drop on Evaporator & Condenser : 5.0 meter maximum (f) Minimum COP: 4.5 (g) Power consumption of Heat Pump for cooling should not exceed 0.90 KW/TR @ 100 % load on design condition. (h) Power consumption of Heat Pump for Heating should not exceed 1.0 KW/TR @ 100 % load on design condition. (j) Each heat pump to have multi compressors (Scroll Compressor) and multi refrigerant circuit in hermetic construction as per OEM design suitable for operation on 415 V +10 %, 50 Hz AC supply all as specified and directed. (k) Suitable Nos & suitable capacity squirrel cage induction motor with class 'F' insulation. (l) First charge of initial oil, R410 A refrigerant and controllers for all the heat pump.

3

-

-

... More
(m) Shell & Tube type Evaporator & Condenser to provide best heat exchange rate to meet COP requirement. 19 mm thick Nitrile rubber insulation from factory on evaporator and suction line. (n) Electronic Expansion valve to control refrigerant precisely. (o) Refrigerant piping fittings, valves, accessories to inter connect compressor, condenser, chiller and expansion valve. (p) Control panel with display comprising of Controls. It shall also be equipped with protection and monitoring devices such as H/L Pressure switch/ Thermal and Current Overload Protector (q) DP/ Flow switches at inlet and outlet of heat pump, water drain & air purge valves, wherever required. (r) Lot-frame work for mounting the above condenser, chiller, compressor and motor with base plate complete with antivibration pads/ springs. (s) Suitable RCC/Cement concrete foundation for the chilling unit installation complete as required as per design of manufacturer. Note : In case the rated capacity of Heat Pump is not avaiable ; Next higher capacity of Heat Pump shall be provided by the Contractor without extra cost.

-

-

-

... More
Supply, installation, testing and commissioning of , FRP Induced draft, Cross flow, Direct driven or driven through reduction gear box, site erected cooling tower of capacity 40 TR at Water Temp. IN : 36.4°C, Water Temp. OUT : 32.2°C and according to the parameters (Flow) as described below. complete all as specified and as directed by Engineer-in- charge. (a) Cooling tower shall be complete with PVC Fills, Louvers , Drift Eliminators with flame spread rating of 5 as per ASTM E84, Weather Proof IP 55 TEAO (Totally Enclosed Air Over) Motor, statically and dynamically balanced Propeller Fan, FRP/ Steel Basin in the bottom of the basin, Hot dip galvanised / powder coated Steel Ladder, Perimeter handrail, Steel hardware including nut, bolt, washer etc., suction screen, make-up quick fill arrangement, overflow and drain connections with necessary valves, access arrangement for cooling tower interior / fan, cement concrete foundation, steel/ masonry supporting structure, anti-vibration mountings etc. For longer life of the product Hot dip galvanization / powder coating on the steel frame and ladder other hardware shall be with minimum G-235 / Poweder coated. (b) The maximum allowable sound power at a distance of 3 Mt for the one cell cooling Tower shall be less than 65 dB at air inlet .

1

-

-

... More
Supply, erection, testing and commissioning of Vertical Inline Split Coupled Centrifugal Condenser water pump set capable of delivering Min. 125 USGPM at 18 Mtr Head of water, each comprising of the following and complete with TEFC squirrel cage induction motor, efficiency IE3 with class 'F" insulation. 1450 rpm synchronous speed, operating on 415+ 10% volts, 3 phase, 50 Hz A.C. supply, BMS compatible. pump shall have CI body, Bronze impeller, spacer coupling and coupling guard, The mechanical seal shall be outside type, The internal components of pumps including mechanical seal shall be suitable to sustain a temperature of 122 degree Fahrenheit. Vendor shall provide antivibration arrangement for pumps as per Manufacturers recommendation . The pump should be rated for PN 16 maximun pressure. Minimum efficiency of pump shall be  55 %. The scope also shall include following. (i) 19mm thick polyvinyl nitrile rubber insulation duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump. (ii) 2 Nos. - 150 mm dia dial type pressure gauges (iii) Mounting frame with antivibration pads ( In case pumps are inline, anti vibration system shall be as per Manufacturers recommendation) (iv) RCC/cement concrete foundation for the pump unit as per Manufacturers recommendation

2

-

-

... More
Supply, erection, testing and commissioning of Vertical Inline Split Coupled Centrifugal primary chilled water pump set capable of delivering 110 US GMP at approx 24 Mtr Head of water, each comprising of the following and complete with TEFC squirrel cage induction motor, efficiency IE3 with class 'F" insulation. 1450 rpm synchronous speed, operating on 415+ 10% volts, 3 phase, 50 Hz A.C. supply, BMS compatible. pump shall have CI body, Bronze impeller, spacer coupling and coupling guard, The mechanical seal shall be outside type, The internal components of pumps including mechanical seal shall be suitable to sustain a temperature of 122 degree Fahrenheit. Vendor shall be provide antivibration arrangement for pumps . Pumps shall have minimum efficiency of pump shall be  55%. Pump shall be rated as PN 16 maximun pressure. The scope also shall include following:- (a) 19mm thick polyvinyl nitrile rubber insulation duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump. (b) 2 Nos. ---- - 150 mm dia dial type pressure gauges (c) Mounting frame with antivibration pads (In case pumps are inline, anti vibration system shall be as per Manufacturers recommendation) (d) RCC/cement concrete foundation for the pump unit as per Manufacturers recommendation

2

-

-

... More
Supplying, installing, testing and commissioning of factory built, site assembled double skin Air Handling unit of capacity 11000CFM for minimum 25 TR with 6RD chilled water coil @ 50 mm static pressure as described below :- (a) Standard 40 or 45 mm thick panels comprising of (i) Outer skin-----0.6 mm precoated GSS (ii) Inner skin ----06 mm precoated GSS (iii) 40 mm thick polyurathene foam insulation having density of 40kg/cum factory injected between them by injection moulding machine, (iv) view windows, (v) marine Lamp, (vi) limit switch, (vii) electrically interlocked fan section with hinged access door, (viii) fire retardant flexible joints for outlets of the units. (ix) Drain connection with stainless steel drain pan duly insulated and necessary vibration isolation arrangement to avoid any vibration etc. (b) The extruded aluminium framework shall be with thermal break profiles as required, minimum 2 bend GSS/PVC eliminators, (c) FAN SECTION :- Supply air fan plug type direct driven Backword curved fan with VFD, TEFC motors (IE3 efficiency) suitable for 415 + 10% volts, 50 Hz, 3 phase AC supply. Fans should be AMCA/ EuroVent certified for Air & sound performance. (d) COIL SECTION WITH 6RD CHW COIL :- (i) Chilled water cooling coil with aluminium finned copper tubes (tube thickness not less than 0.5mm), The face velocity across cooling coil shall be limited to 450FPM maximum AHU should have Cooling Coil (6 row Deep) . AHU Should be either Eurovent or equivalent certified.

1

-

-

... More
(ii) The scope shall include, Testing and Commissioning of following sizes electronic, self balancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valves in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and not be less than 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum. Valve & Actuator combination should be able to give logarithmic control characteristics to achieve linear control.The valve shall have manual override facility & the scope shall include proportionate thermostat, transformer as required and wiring for interconnection with 1.5 sq.mm copper conductor multicore armoured cable complete as required. (e) Supply air stream will have Filter section complying minimum MERV (Minimum Efficiency Reporting Value) 13 or higher having pre (EU4, more than 90% efficiency for 10 Microns), fine (Bag filter EU7, 5 Microns). (f) The scope shall include Humidity and Temperature for Desired Inside Temperature condition. (g) The capacity of Air-handlers shall be as follows: (i) Capacity

-

-

-

... More
Supplying, fixing, testing and commissioning of condenser water pipes nominal bore of size 80mm diameters, MS C Class, and materials along with necessary clamps, vibration isolators, and fitting such as bends, tees etc. but excluding valves, strainer and gauges etc adequately supported on rigid supports etc as per complete all as specified and as directed by Engineer-in- charge.

36

-

-

... More
Ditto all as per above Srl item No.103 but bore of size 50mm complete all as specified and as directed by Engineer-in-charge.

30

-

-

... More
Supplying, fixing, testing and commissioning 80mm dia buterfly valves (Complete with Flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), strainers(Complete with flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), gauges etc for condenser water circulation as per specifications.Insulation shall be with two half round sections of PUF (Polyurethane) in density 36±2 Kg/m³ conforming to IS: 12436. Sections shall be bonded to the surface of pipe with adhesive fevicol SR 998 and binded with metal binding wire, apply fevicol AC Duct Lag Coating AF:5590 on insulated surface uniformly and wrap the Glass Cloth tightly with over laping so that no gaps are left and no air pockets are formed. Immediately apply additional coating as a finish layer on the wrap cloth, and finally finish with necessary hardware fitting. --Butterfly Valve with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets complete all as specified and as directed by Engineer-in-charge.

6

-

-

... More
Ditto all as per above Srl item No.105 but size of 50mm complete all as specified and as directed by Engineer-in-charge.

6

-

-

... More
Supply installation testing and commissioning of 80mm diameter balancing valves (complete with Flanges integral or welded, fittings. Nuts, bolts & gaskets (PN-16 rating), EPDM coated disc with built in measuring facility strainers (complete with flanges integral or welded, fittings, nuts & bolts and gaskets (PN-16 rating), gauges etc for condenser water circulation as per specification Balancing valve) complete all as specified and as directed by Engineer-in-charge.

2

-

-

... More
Ditto all as per above Srl item No.107 but size of 50mm complete all as specified and as directed by Engineer-in-charge.

6

-

-

... More
Supply , installation , testing and commissioning of water pressure gauge (100 mm Ø) bourdon type with brass ball valve of 3/8" Ø and SS tubing, socket. Range (0-50) / (0-100) as required complete all as specified and as directed by Engineer-in- charge.

12

-

-

... More
Supply , installation , testing and commissioning of Mercury in glass industrial thermometer in SS-304 casing with 0.5 C least count, range 0-50 C. Brass oil filled thermowell of 1/2" size. complete all as specified and as directed by Engineer-in- charge.

12

-

-

... More
Supply & fabrication of MS structure like Angle, channel, I section for make up tank foundation & condenser water line supports. The MS shall be painted with two coats of red oxide primer & finally painted with Balck enamel paint.complete all as specified and as directed by Engineer-in- charge.

100

-

-

... More
Supplying, laying/ fixing, testing and commissioning nominal sizes of 80mm dia chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-(i) The Pipes of sizes 150mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. (ii) For pipes up to 125mm dia. the thickness of insulation shall be 50mm and for pipes above 125mm dia. the thickness of insulation shall be 75mm

50

-

-

... More
Ditto all as per above Srl item No.112 but size of 50mm complete all as specified and as directed by Engineer-in-charge.

30

-

-

... More
Supply , instalation , testing and commissioning 80mm diametre of C.I. Butterfly valve (PN-16) with CI body SS disc, with integral or separate welded Flange /wafer type construction with EPDM coated disc with long pitch with protected out pipe insulation and PN 16 pressure rating for chilled circulation as specified. The valves above 150 mm dia shall be with geat box for operation complete all as specified and as directed by Engineer-in-charge.

8

-

-

... More
Ditto all as per above Srl item No.115 but size of 50mm complete all as specified and as directed by Engineer-in-charge.

6

-

-

... More
Supply , installation , testing and commissioning of Plug valves - 25mm diameter Plug valves in dirt legs complete all as specified and as directed by Engineer-in- charge.

3

-

-

... More
Supply , instalation , testing and commissioning of water pressure gauge (100 mm Ø) bourdon type with brass ball valve of 3/8" Ø and SS tubing, socket. Range (0-50) / (0-100) as required. complete all as specified and as directed by Engineer-in- charge.

16

-

-

... More
Supply , instalation , testing and commissioning of Mercury in glass industrial thermometer in SS-304 casing with 0.50°C least count, range 0-50°C. Brass oil filled thermowell of 1/2" size complete all as specified and as directed by Engineer-in- charge.

16

-

-

... More
Supply, installation , testing and commissioning of 20mm Automatic Air Vent valve suitable to purge out the trapped air in the water pipe line complete as required. complete all as specified and as directed by Engineer-in- charge.

8

-

-

... More
Supplying, fixing, testing and commissioning 50mm dia of medium class G.I. condensate drain pipes on wall/floor/roof of following size/diameters duly insulated with 9 mm thick closed cell nitrile rubber insulation in the form of pre-formed pipe sections and along with necessary clamps, fittings such as bends, tees etc. adequately supported as per specifications and as required.

20

-

-

... More
Supply & Fix PVC Tank capacity of 500 Ltrs for Chilled water expansion tank and shall be duly insulated with 50 mm thick EPS insulating material and cladded with aluminium Sheet (20G) complete with foundation and inlet, outlet and over flow pipe connection all as specified. complete all as specified and as directed by Engineer-in- charge.

1

-

-

... More
Supply & Fix PVC Make Up Water Tank of capacity 3000 Ltrs for Cooling Tower complete with foundation and inlet, outlet and over flow pipe connection complete all as specified and as directed by Engineer-in- charge. Note - Make up tank shall be placed on roof of Plant room. Foundation required for installation of Tank is included in cost quoted by contractor.

1

-

-

... More
Supply, Installation, Testing Balancing & Commissioning of rectangular/round Hot dipped Galvanised .80mm thick sheet with 120 GSM Zinc coating ducting as per IS 655 - 2006 complete with gaskets, elbows, splitters, vanes, supports adjustable dampers, etc. as per approved drawingsas required for dehumidified air distribution of following thickness as per approved working drawings, specifications and requirement .(Factory Fabricated/Site Manufactured).The price shall include necessary scaffolding required for working at required height. Contractor should also include the cost of core cut to be made in wall for Fresh air lovers and Fresh Air Duct for AHU's . Note - Design of duct shall be subimitted by conractor to GE for approral .Based on approved design of ducting ,work shall be carried out.

120

-

-

... More
Ditto all as per above Srl item No.123 but 0.63 mm thickness complete all as specified and as directed by Engineer-in-charge.

180

-

-

... More
Supply and fix Grills / Diffusers made of aluminium section duly powder coated paint for supply air with volume control damper complete all as specified and as directed by Engineer-in-charge.

3

-

-

... More
Supply and fix Grills / Diffusers made of aluminium section duly powder coated paint for supply air with volume control damper complete all as specified and as directed by Engineer-in-charge.

3

-

-

... More
Supply and fix Fresh Air Grills made of aluminium section duly powder coated paint complete all as specified and as directed by Engineer-in-charge.

1

-

-

... More
Supply and fix Flexible Canvas Connection complete all as specified and as directed by Engineer-in-charge.

1

-

-

... More
Supply & Installation of Thermal Insulation of thicknes 13 mm on Ducts not exposed to sunlight using Closed Cell Class O Nitrile Rubber Elastomeric Insulation of Density 40 - 55 Kg/m3 , Thermal Conductivity of 0.037 W/mk at 200 Celcius Mean Temp. and μ≥7000 (without any additional vapour barrier) and with factory laminated aluminium foil of minimum 60 Microns thickness having weight of 193 gsm as per EN ISO 2286-2, tensile strength shall be 90N/15mm as per EN ISO 527-3 with elongation 10% as per EN ISO 527-3; to be applied on Ducts using manufacturer's recommended Rubber based Adhesive in a blend of Solvents. complete all as specified and as directed by Engineer-in-charge.

280

-

-

... More
Supply and Application of Acoustic Insulation of thickness 15 mm Inside the Duct with Engineered Nitrile Rubber open cell foam with Density 140 - 180 Kg/m3 passing Class 1 Fire Performance test as per BS 476 Part 7, Air Erosion test for 10,000 fpm air velocity as per ASTM C 1071-05 and with built-in antimicrobial protection. The material should pass Fungi Resistance Test as per DIN EN ISO 846 Method A and Bacterial Resistance Test as per DIN EN ISO 846 Method C; to be applied using manufacturer's recommended Rubber based Adhesive in a blend of solvents complete all as specified and as directed by Engineer-in-charge.

20

-

-

... More
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required complete all as specified and as directed by Engineer-in-charge.

2

-

-

... More
Supplying, installation, testing & commissioning of cubical type wall / floor mounted Distribution Panel suitable for 415 V, 3 Phase, 4Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 2mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having Suitable Amp capacity extensible type FP Aluminium Alloy bus bars of high conductivity, SMC bus bar supports, with short circuit withstand capacity of 35kA for I Sec. with entire panel shall have a common Alu earth bus of size 32x6mm at the rear with 2 Nos earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with 2.5 sq.mm. PVC insulated FRLS copper conductor Single Core cable, cable alleys, cable gland plates in two half, i/c additional NO/NC contacts in all outgoing starters for automatic operation and providing & fixing following switch gears:- (b) Each MCCB shall be with the following. (i) Extended Rotary Operating Handle, Phase Spreader links and Phase barriers (ii) 1 Set - Digital Ammeter with in built ASS, metering C.T.s "CAST RESIN" type, 15VA, and accuracy class-1of 200/5A for measuring current in each phase (iii) 1 Set - 0 -500 Volts Digital Voltmeter with in built VSS, with 2Amp. Back up MCB (iv) 1 Set - 3 Nos. Phase indication LED lamps with 2Amp back up MCB, Breaker 'ON/OFF' indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. - 2 Set (v) 1 No. Suitable Electronic Digital type Energy Meter (vi) Each Panel will have Junction box with holes punched for connecting it to existing panel through Cable. (c) Incomer - (A) 1 No. - 160 Amps Four Pole, 36 KA (ICU=ICS) for 1 sec, MCCB with Microprocessor release with O/C, S/C & E/F protection release, each MCCB each shall be with following:-

1

-

-

... More
(i) Extended Rotary Operating Handle, Phase Spreader links and Phase barriers (ii) Electrical & mechanical interlocking of above MCCBs so that only one MCCB can be switch on at one time. (iii) 1 Set - Digital Ammeter with in built ASS, metering C.T.s "CAST RESIN" type, 15VA, and accuracy class-1, 200/5A for measuring current in each phase (iv) 1 Set - Digital Voltmeter with in built VSS, with 2Amp. Back up MCB (v) 1 Set - 3 Nos. Phase indication LED lamps with 2Amp back up MCB, Breaker 'ON/OFF' indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. - 2 Set (vi) Digital multi function energy meter 96x96 mm (vii) Each Panel will have Junction box with holes punched for connecting it to existing panel through Cable. (B) Bus Bar :- Four poleTPN aluminium extensible type main bus bars of minimum of 250 A capacity (As per capacity of corresponding incoming / Bus couplers) , and auxiliary bus bars of suitable capacity with heat shrunk coloured sleeves and i/c SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 35kA for 1 Sec. (C) Outgoings:-Supplying and fixing following outgoing MCCB / MCB complete connection, inter-connection etc. with suitable size of solid links / wires (2A backup SP MCB) complete as required. (i) 3 Nos- 63 Amps 10 KA TP MCB ( for Heat Pump) (ii) 4 Nos. - 32 A 10 KA TP MCB with DOL Starter and single phase preventor ( For pump) (iii) 1 No. - 32 A 10 KA TP MCB with DOL Starter & single phase preventor (for Cooling Tower) (iv) 1 No. - 32 A 10 KA TP MCB with VFD type Starter (For AHU) (v) Each MCCB / MCB s shall be with following accessories Note :- (i)MCCB for over current & shortcircuit protection and breaking capacity of 25 kA,at 433V (Ics=ku for 1 second) (ii)Extended Type front door operating handle, phase spreaders and phase barriers. (iii) 1 set - Breaker 'ON/OFF' indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts as required. Note - Drawings for LT Panel shall be got approved from GE before fabrication.

-

-

-

... More
Supply & Laying/ fixing of 3.5 Core x 25 sq.mm. ( Heat Pump) XLPE LT Cables insulated and PVC insulation Aluminium conductor armoured cable as required of 1.1 KV grade complete as required.(ISI Marked) ( in ground/in pipe/in duct/on surface/ on cable tray) Note -Item for cable tray shall be measured and paid seperately. complete all as specified and as directed by Engineer-in-charge.

50

-

-

... More
Ditto all as per above Srl item No.133 but 3 Core x 4 sq.mm (Pump and cooling tower) complete all as specified and as directed by Engineer-in-charge.

50

-

-

... More
Ditto all as per above Srl item No.133 but 4 Core x 6 sq.mm. (AHU) complete all as specified and as directed by Engineer-in-charge.

40

-

-

... More
Ditto all as per above Srl item No.133 but 4 Single core x 1.5 sq.mm. (Copper for Controls) complete all as specified and as directed by Engineer-in-charge.

50

-

-

... More
Supplying and installing 150 mm width X 50 mm depth X 1.6 mm thickness size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required complete all as specified and as directed by Engineer-in-charge.

35

-

-

... More
Ditto all as per above Srl item No.137 but 300 mm width X 50 mm depth X 1.6 mm thickness complete all as specified and as directed by Engineer-in-charge.

35

-

-

... More
Supply & fixing/laying GI earth strip 32 mm x 6 mm below ground, in 40 mm GI pipe wherever required and on surface or in recess for connections etc. complete all as specified and as directed by Engineer-in-charge.

100

-

-

... More
Supply & fixing of 8 SWG wire complete all as specified and as directed by Engineer-in-charge.

100

-

-

... More
Note- (a) Any Minor parts required for successful commissing of Plant are deemed to be included in rates quoted by Contractor .Nothing extra shall be payable on this account. (b) Plant shall be run on a trial basis for a period of one month.Only after successful operation of Plant during trial period ,Completion shall be issued by GE .Man power required during Trial period shall be arranged by contractor. (c ) Central Air Conditiong work shall be executed by a specialized agency which has carried out similar type of work. Name of spexializes agency shall be approved by GE.

-

-

-

... More
Subtotal

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.