If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 4,65,000Document Cost
₹ 2,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_679468_1Tender No
80331/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Dismantling earth wire or copper conductor, service line any description / size, in any position and proper stacking in position for further disposal complete all as directed.
4.1
-
-
Dismantling insulators of any description / size, in any position and proper stacking in position further disposal complete all as directed.
1720
-
-
Dismantling stay assembly complete of any description / size, including excavation,demolition of concrete etc in any position and proper stacking in position for further disposal complete all as directed.
28
-
-
Dismantling cross-arms of M.S. channel or angle sections complete and proper stacking in position for further disposal complete all as directed.
26.5
-
-
Dismantling/taking down old serviceable/unserviceable light fitting from the pole and serviceable light fitting kept in safe of for re-fixing and unserviceable fittings properly stacked the for further disposal complete all as directed.
480
-
-
Dismantling/taking down old unserviceable junction boxes of any size or description from the pole and properly stacking for further disposal complete all as directed.
10
-
-
Taking down old unserviceable LT UG Cable from trenches/on poles/ Floor / roof of any size / description and proper stacking in position for further disposal complete all as directed.
1990
-
-
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for laying cables and getting out in hard/dense soil complete all as specified and directed.
7016
-
-
Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m in depth for foundation etc or for laying of cables/ errection of poles / struts / stays / stay assembly etc not exceeding 10 sqm on plan and getting out in soft / loose soil complete all as specified and directed.
62
-
-
Returning filling in excavated soil including spreading levelling and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
4373
-
-
Removing surplus excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
2643
-
-
Supply and spread dry river washed sand free from foreign material in trenches for cable cushioning and punning down complete all as specified and directed.
Note:- Punned thickness of sand will be measured & considered for payment purpose only.
1920
-
-
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat, ISI marked, size 250mm x 150mm x 40 mm complete all as specified and as directed.
158040
-
-
M&L for cement concrete 1:3:6 type C2 using 40 mm graded as in foundation filling and mass concrete complete all as specified and as directed.
202.1
-
-
M&L for cement concrete type B1, 1:2:4 (using 20 mm graded stone aggregate) for coping including form work etc complete all as specified and directed.
46.5
-
-
Material and labour for plain cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundations, filling and mass- concrete, complete all as specified & directed.
20.5
-
-
Supply, laying and testing cable XLPE insulated, PVC bedded, galvanised steel strip or wire armoured , ISI marked, electric power cable (heavy duty) 1100 volts grade with standard aluminium conductor of size 3.5 core 240 sq mm complete all as specified & directed.
407
-
-
All as per item No 19 here-in-before but the size of cable 3.5 core 630 Sq mm
198
-
-
All as per item No 19 here-in-before but the size of cable 3.5 core 400 Sq mm
407
-
-
All as per item No 19 here-in-before but the size of cable 3.5 core 185 Sq mm
380
-
-
All as per item No 19 here-in-before but the size of cable 3.5 core 150 Sq mm
1507
-
-
All as per item No 19 here-in-before but the size of cable 3.5 core 120 Sq mm
2930
-
-
All as per item No 19 here-in-before but the size of cable 3.5 core 70 Sq mm
100
-
-
All as per item No 19 here-in-before but the size of cable 3.5 core 95 Sq mm
1452
-
-
All as per item No 19 here-in-before but the size of cable 3.5 core 35 Sq mm
1573
-
-
All as per item No 19 here-in-before but the size of cable 4 core 25 Sq mm
9360
-
-
All as per item No 19 here-in-before but the size of cable 4 core 16 Sq mm
9075
-
-
All as per item No 19 here-in-before but the size of cable 2 core10 Sq mm
500
-
-
Note for item no 19 to 30 :
i) Cable shall be as per Central testing lab standard
ii) Factory inspection shall be done by MES rep before dispatch of cables from factory
iii) Cables shall be ISI marked with IS 7098(2011)
-
-
-
Supply, erecting and fixing in true vertical position, steel tubular swaged pole (410 SP – 31), 09 meter long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole with and including necessary earth work in any type of soil and disposal of surplus soil to a distance not exceeding 50 meter, including 2 coat of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint, Numbering of the poles with synthetic enamel painted letter of shape & size as directed, complete all as specified and directed. Note : PCC for foundation and coping of pole will be measured and paid separately under appropriate item, However Earth work shall be included in this item.
380
-
-
Supply and fixing PVC junction box 250x200x105 mm having copper bus strips suitable for up to 25 sq mm cable including necessary clamps, nut bolts and washers for fixing on steel tublar pole and including one No MCB SP 6 amps complete all as specified and directed.
480
-
-
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
144
-
-
Refixing of dismantled serviceable street light on poles/walls, making necessary connections complete all as specified and directed.
336
-
-
M&L for drilling suitable dia horizontal bore holes for insertion/ laying of 100 mm bore HDPE pipe below/under existing road surfaces / apron /floors etc with using mechanical or manual devices as required at site including making good the disturbed surfaces to match with the existing streta after laying pipes including supply and laying HDPE pipe of 100 mm dia complete all as specified and directed.
1150
-
-
Supply, installation, testing and commissioning of LT Panel/Feeder Pillar box, three phase four wire, 415 Volts outdoor type, maufactured by CPRI approved manufacturer , free standing, floor mounting, double door, dust and vermin proof cubical type, fabricated out 3.15 MM CRCA sheet with anit corrosive coating and finally epoxy polyster powder coating of approved colour fully compartm- entalized design with 04 Nos of aluminiun bus suitable for 1000 Amps , pre-wired with suitable size of copper cable/insulated copper strip short circuit rating 50 KA (rms) for one second and frame & Legs made out 50 x 50 x 6 mm angle iron for LT panel fixed on and including PCC (1:3:6) foundation, bricks works in CM 1:4 duly plastered in CM 1:4 and necessary earth work etc. 4 nos lifting hook to be provided at top of panel, includinig supply and fixing of the following components complete all as specified and directed :- LOCATION : DILBAGH (LT PANEL 01)
1) Incomming:-
(a) Bus bars of aluminium strips of 1000 Amp having current density not less than 130A/cm2, current rating capacity mounted on epoxy/FRP bus bar insulator - 01 set.
(b) MCCB 630 Amps TPN 50 KA, 415 V ,Microprocessor type having L.S.I.G protection and trip display type with handle operated spring charging mechanism manual drawout type - 01 Nos.
(c) 3 phase voltmeter,ameter and power factor meter with necessary size of CT and internal wiring
(d) Indicating lamp set of 03 R,Y,B
2) OUT GOING
(a) MCCB 250A Amps TPN 35/36 KA 415 Volts thermal megnatic release type having load adjustment setting 80% to 100% having Icu=Ics=100% - 01 Nos.
(b) MCCB 200 Amps TPN 35/36 KA 415 Volts thermal megnatic release type having load adjustment setting 80% to 100% having Icu=Ics=100% - 02 Nos.
(c) MCCB 100 A Amps TPN 25 KA 415 Volts thermal megnatic release type having load adjustment setting 80% to 100% having Icu=Ics=100% - 01 Nos.
(d) MCCB 40 A Amps TPN 16 KA 415 Volts thermal megnatic release type having load adjustment setting 80% to 100% having Icu=Ics=100% - 01 Nos.
NOTE : (i) All outgoing feeder shall be connected with suitable size of bus bar. (ii) Bottom of LT Panel should be 600 mm above the ground level.
1
-
-
Supply, installation, testing and commissioning of LT Panel/Feeder Pillar box, three phase four wire, 415 Volts outdoor type, maufactured by CPRI approved manufacturer, free standing, floor mounting, double door, dust and vermin proof cubical type, fabricated out 3.15 MM CRCA sheet with anit corrosive coating and finally epoxy polyster powder coating of approved colour fully compartm- entalized design with 04 Nos of aluminiun bus suitable for 400 Amps having current density not less than 130A/cm2, pre-wired with suitable size of copper cable/insulated copper strip short circuit rating 50 KA (rms) for one second and frame & Legs made out 50 x 50 x 6 mm angle iron for LT panel fixed on and including PCC (1:3:6) foundation, bricks works in CM 1:4 duly plastered in CM 1:4 and necessary earth work etc. 4 nos lifting hook to be provided at top of panel, includinig supply and fixing of the following components complete all as specified and directed :- LOCATION : DILBAGH(LT PANEL NO 02)
1) Incomming:-
(a) Bus bars of aluminium strips of 400 Amp having current density not less than 130A/cm2 current rating capacity mounted on epoxy/FRP bus bar insulator - 01 set.
(b) MCCB 250A Amps TPN 35/36 KA 415 Volts thermal megnatic release type having load adjustment setting 80% to 100% having Icu=Ics=100% - 01 Nos.
(c) 3 phase voltmeter, ameter and power factor meter with necessary size of CT and internal wiring
(d) Indicating lamp set of 03 R,Y,B
2) OUT GOING
(a) MCCB 40 A Amps TPN 16 KA 415 Volts thermal megnatic release type having load adjustment setting 80% to 100% having Icu=Ics=100% - 09 Nos.
(b) MCCB 32 A Amps TPN 16 KA 415 Volts thermal megnatic release type having load adjustment setting 80% to 100% having Icu=Ics=100% - 01 Nos.
NOTE : (i) All outgoing feeder shall be connected with suitable size of bus bar. (ii) Bottom of LT Panel should be 600 mm above the ground level.
1
-
-
Supply, installation, testing and commissioning of LT Panel/Feeder Pillar box, three phase four wire, 415 Volts outdoor type, maufactured by CPRI approved manufacturer, free standing, floor mounting, double door, dust and vermin proof cubical type, fabricated out 3.15 MM CRCA sheet with anit corrosive coating and finally epoxy polyster powder coating of approved colour fully compartm- entalized design with 04 Nos of aluminiun bus suitable for 300 Amps having current density not less than 130A/cm2 current rating capacity , pre-wired with suitable size of copper cable/insulated copper strip short circuit rating 50 KA (rms) for one second and frame & Legs made out 50 x 50 x 6 mm angle iron for LT panel fixed on and including PCC (1:3:6) foundation, bricks works in CM 1:4 duly plastered in CM 1:4 and necessary earth work etc. 4 nos lifting hook to be provided at top of panel, includinig supply and fixing of the following components complete all as specified and directed :- LOCATION : DILBAGH (LT PANEL NO 03)
1) Incomming:-
(a) Bus bars of alluminium strips of 300 Amp having current density not less than 130A/cm2 current rating capacity mounted on epoxy/FRP bus bar insulator - 01 set.
(b) MCCB 200 Amps TPN 35/36 KA 415 Volts thermal megnatic release type having load adjustment setting 80% to 100% having Icu=Ics=100% - 01 Nos.
(c) 3 phase voltmeter,ameter and power factor meter with necessary size of CT and internal wiring
(d) Indicating lamp set of 03 R,Y,B
2) OUT GOING
(a) MCCB 40 Amps TPN 16 KA 415 Volts thermal megnatic release type having load adjustment setting 80% to 100% having Icu=Ics=100% - 05 Nos.
(b) MCCB 32 Amps TPN 10 KA 415 Volts - 01 No.
NOTE : (i) All outgoing feeder shall be connected with suitable size of bus bar. (ii) Bottom of LT Panel should be 600 mm above the ground level.
1
-
-
Supply, installation, testing and commissioning of LT Panel/Feeder Pillar box, three phase four wire, 415 Volts outdoor type, maufactured by CPRI approved manufacturer, free standing, floor mounting, double door, dust and vermin proof cubical type, fabricated out 3.00 MM CRCA sheet with anit corrosive coating and finally epoxy polyster powder coating of approved colour fully compartm- entalized design with 04 Nos of aluminiun bus suitable for 300 Amps having current density not less than 130A/cm2 current rating capacity, pre-wired with suitable size of copper cable/insulated copper strip short circuit rating 50 KA (rms) for one second and frame & Legs made out 50 x 50 x 6 mm angle iron for LT panel fixed on and including PCC (1:3:6) foundation, bricks works in CM 1:4 duly plastered in CM 1:4 and necessary earth work etc. 4 nos lifting hook to be provided at top of panel, includinig supply and fixing of the following components complete all as specified and directed :- LOCATION : DILBAGH (LT PANEL NO 04)
1) Incomming:-
(a) Bus bars of alluminium strips of 300 Amp having current density not less than 130A/cm2 current rating capacity mounted on epoxy/FRP bus bar insulator - 01 set.
(b) MCCB 200 Amps TPN 35/36 KA 415 Volts thermal megnatic release type having load adjustment setting 80% to 100% having Icu=Ics=100% - 01 Nos.
(c) 3 phase voltmeter,ameter and power factor meter with necessary size of CT and internal wiring
(d) Indicating lamp set of 03 R,Y,B
2) OUT GOING
(a) MCCB 40 Amps TPN 16 KA 415 Volts thermal megnatic release type having load adjustment setting 80% to 100% having Icu=Ics=100% - 06 Nos.
(b) MCCB 32 Amps TPN 10 KA 415 Volts - 01 Nos.
NOTE : (i) All outgoing feeder shall be connected with suitable size of bus bar. (ii) Bottom of LT Panel should be 600 mm above the ground level.
1
-
-
Supply, installation, testing and commissioning of LT Panel/Feeder Pillar box, three phase four wire, 415 Volts outdoor type, maufactured by CPRI approved manufacturer, free standing, floor mounting, double door, dust and vermin proof cubical type, fabricated out 3.15 MM CRCA sheet with anit corrosive coating and finally epoxy polyster powder coating of approved colour fully compartm- entalized design with 04 Nos of aluminiun bus suitable for 150 Amps having current density not less than 130A/cm2 current rating capacity, pre-wired with suitable size of copper cable/insulated copper strip short circuit rating 50 KA (rms) for one second and frame & Legs made out 50 x 50 x 6 mm angle iron for LT panel fixed on and including PCC (1:3:6) foundation, bricks works in CM 1:4 duly plastered in CM 1:4 and necessary earth work etc. 4 nos lifting hook to be provided at top of panel, includinig supply and fixing of the following components complete all as specified and directed :- LOCATION : LT PANEL NO 05
1) Incomming:-
(a) Bus bars of aluminium strips of 150 Amp having current density not less than 130A/cm2 current rating capacity mounted on epoxy/FRP bus bar insulator - 01 set.
(b) MCCB 100 Amps TPN 25 KA 415 Volts thermal megnatic release type having load adjustment setting 80% to 100% having Icu=Ics=100% - 01 No.
(c) 3 phase voltmeter,ameter and power factor meter with necessary size of CT and internal wiring
(d) Indicating lamp set of 03 R,Y,B
2) OUT GOING
(a) MCCB 40 Amps TPN 16 KA 415 Volts thermal megnatic release type having load adjustment setting 80% to 100% having Icu=Ics=100% - 03 Nos.
(b) MCCB 32 Amps TPN 10 KA 415 Volts - 03 No.
NOTE : (i) All outgoing feeder shall be connected with suitable size of bus bar. (ii) Bottom of LT Panel should be 600 mm above the ground level.
1
-
-
Supply, installation, testing and commissioning of LT Panel/Feeder Pillar box, three phase four wire, 415 Volts outdoor type, maufactured by CPRI approved manufacturer, free standing, floor mounting, double door, dust and vermin proof cubical type, fabricated out 3.15 MM CRCA sheet with anit corrosive coating and finally epoxy polyster powder coating of approved colour fully compartm- entalized design with 04 Nos of aluminiun bus suitable for 250 Amps having current density not less than 130A/cm2, pre-wired with suitable size of copper cable/insulated copper strip short circuit rating 50 KA (rms) for one second and frame & Legs made out 50 x 50 x 6 mm angle iron for LT panel fixed on and including PCC (1:3:6) foundation, bricks works in CM 1:4 duly plastered in CM 1:4 and necessary earth work etc. 4 nos lifting hook to be provided at top of panel, includinig supply and fixing of the following components complete all as specified and directed :- LOCATION : ARJUN (LT PANEL NO 01)
1) Incomming:-
(a) Bus bars of alluminium strips of 250 Amp having current density not less than 130A/cm2 current rating capacity mounted on epoxy/FRP bus bar insulator - 01 set
(b) MCCB 160 Amps TPN 35/36 KA 415 Volts thermal megnatic release type having load adjustment setting 80% to 100% having Icu=Ics=100% - 01 Nos. (c) 3 phase voltmeter,ameter and power factor meter with necessary size of CT and internal wiring
(d) Indicating lamp set of 03 R,Y,B
2) OUT GOING
(a) MCCB 40 Amps TPN 16 KA 415 Volts thermal megnatic release type having load adjustment setting 80% to 100% having Icu=Ics=100% -06 Nos (b) MCB 32 Amps TPN 10 KA 415 Volts-01Nos.
NOTE : (i) All outgoing feeder shall be connected with suitable size of bus bar. (ii) Bottom of LT Panels should be 600 mm above the ground level.
1
-
-
Supply, installation, testing and commissioning of LT Panel/Feeder Pillar box, three phase four wire, 415 Volts outdoor type, maufactured by CPRI approved manufacturer, free standing, floor mounting, double door, dust and vermin proof cubical type, fabricated out 3.15 MM CRCA sheet with anit corrosive coating and finally epoxy polyster powder coating of approved colour fully compartm- entalized design with 04 Nos of aluminiun bus suitable for 250 Amps having current density not less than 130A/cm2, pre-wired with suitable size of copper cable/insulated copper strip short circuit rating 50 KA (rms) for one second and frame & Legs made out 50 x 50 x 6 mm angle iron for LT panel fixed on and including PCC (1:3:6) foundation, bricks works in CM 1:4 duly plastered in CM 1:4 and necessary earth work etc. 4 nos lifting hook to be provided at top of panel, includinig supply and fixing of the following components complete all as specified and directed :- LOCATION : ARJUN (LT PANEL NO 02,03,04 )
1) Incomming:-
(a) Bus bars of aluminium strips of 250 Amp having current density not less than 130A/cm2 current rating capacity mounted on epoxy/FRP bus bar insulator - 01 set
(b) MCCB 160 Amps TPN 35/36 KA 415 Volts thermal megnatic release type having load adjustment setting 80% to 100% having Icu=Ics=100% - 01 Nos. (c) 3 phase voltmeter,ameter and power factor meter with necessary size of CT and internal wiring
(d) Indicating lamp set of 03 R,Y,B
2) OUT GOING
(a) MCCB 40 Amps TPN 16 KA 415 Volts thermal megnatic release type having load adjustment setting 80% to 100% having Icu=Ics=100% -08 Nos (b) MCB 32 Amps TPN 10 KA 415 Volts-01No.
NOTE : (i) All outgoing feeder shall be connected with suitable size of bus bar. (ii) Bottom of LT Panel should be 600 mm above the ground level.
3
-
-
Supply, installation, testing and commissioning of LT Panel/Feeder Pillar box, three phase four wire, 415 Volts outdoor type, maufactured by CPRI approved manufacturer, free standing, floor mounting, double door, dust and vermin proof cubical type, fabricated out 3.15 MM CRCA sheet with anit corrosive coating and finally epoxy polyster powder coating of approved colour fully compartm- entalized design with 04 Nos of aluminiun bus suitable for 1000 Amps pre-wired with suitable size of copper cable/insulated copper strip short circuit rating 50 KA (rms) for one second and frame & Legs made out 50 x 50 x 6 mm angle iron for LT panel fixed on and including PCC (1:3:6) foundation, bricks works in CM 1:4 duly plastered in CM 1:4 and necessary earth work etc. 4 nos lifting hook to be provided at top of panel, includinig supply and fixing of the following components complete all as specified and directed :- LOCATION : LATIF (LT PANEL 01)
1) Incomming:-
(a) Bus bars of aluminium strips of 1000 Amp having current density not less than 130A/cm2 current rating capacity mounted on epoxy/FRP bus bar insulator - 01 set
(b) MCCB 630 Amps TPN 50 KA 415 Volts thermal megnatic release type having load adjustment setting 80% to 100% having Icu=Ics=100% - 01 Nos. (c) 3 phase voltmeter,ameter and power factor meter with necessary size of CT and internal wiring
(d) Indicating lamp set of 03 R,Y,B
2) OUT GOING
(a) MCCB 250 Amps TPN 35/36 KA 415 Volts thermal megnatic release type having load adjustment setting 70% to 100% -01 Nos (b) MCCB 200 Amps TPN 50 KA, 415 Vthermal megnatic release type having load adjustment setting 80% to 100% having Icu=Ics=100% -01 Nos. (c) MCCB 160 Amps TPN 50 KA, 415 Vthermal megnatic release type having load adjustment setting 80% to 100% having Icu=Ics=100% -02 Nos.
(d) MCCB 40 Amps TPN 50 KA, 415 Vthermal megnatic release type having load adjustment setting 80% to 100% having Icu=Ics=100% -02 Nos.
NOTE : (i) All outgoing feeder shall be connected with suitable size of bus bar. (ii) Bottom of LT Panel should be 600 mm above the ground level.
1
-
-
Supply, installation, testing and commissioning of LT Panel/Feeder Pillar box, three phase four wire, 415 Volts outdoor type, maufactured by CPRI approved manufacturer, free standing, floor mounting, double door, dust and vermin proof cubical type, fabricated out 3.15 MM CRCA sheet with anit corrosive coating and finally epoxy polyster powder coating of approved colour fully compartm- entalized design with 04 Nos of aluminiun bus suitable for 400 Amps having current density not less than 130A/cm2 pre-wired with suitable size of copper cable/insulated copper strip short circuit rating 50 KA (rms) for one second and frame & Legs made out 50 x 50 x 6 mm angle iron for LT panel fixed on and including PCC (1:3:6) foundation, bricks works in CM 1:4 duly plastered in CM 1:4 and necessary earth work etc. 4 nos lifting hook to be provided at top of panel, includinig supply and fixing of the following components complete all as specified and directed :- LOCATION : LATIF (LT PANEL NO 02 )
1) Incomming:-
(a) Bus bars of aluminium strips of 400 Amp having current density not less than 130A/cm2 current rating capacity mounted on epoxy/FRP bus bar insulator - 01 set
(b) MCCB 250 Amps TPN 35/36 KA 415 Volts thermal megnatic release type having load adjustment setting 80% to 100% having Icu=Ics=100% - 01 Nos. (c) 3 phase voltmeter,ameter and power factor meter with necessary size of CT and internal wiring
(d) Indicating lamp set of 03 R,Y,B
2) OUT GOING
(a) MCCB 40 Amps TPN 16 KA 415 Volts thermal megnatic release type having load adjustment setting 80% to 100% having Icu=Ics=100% -08 Nos (b) MCB 32 Amps TPN 10 KA 415 Volts-01No.
NOTE : (i) All outgoing feeder shall be connected with suitable size of bus bar. (ii) Bottom of LT Panel should be 600 mm above the ground level.
1
-
-
Supply, installation, testing and commissioning of LT Panel/Feeder Pillar box, three phase four wire, 415 Volts outdoor type, maufactured by CPRI approved manufacturer, free standing, floor mounting, double door, dust and vermin proof cubical type, fabricated out 3.15 MM CRCA sheet with anit corrosive coating and finally epoxy polyster powder coating of approved colour fully compartm- entalized design with 04 Nos of aluminiun bus suitable for 250 Amps having current density not less than 130A/cm2, pre-wired with suitable size of copper cable/insulated copper strip short circuit rating 50 KA (rms) for one second and frame & Legs made out 50 x 50 x 6 mm angle iron for LT panel fixed on and including PCC (1:3:6) foundation, bricks works in CM 1:4 duly plastered in CM 1:4 and necessary earth work etc. 4 nos lifting hook to be provided at top of panel, includinig supply and fixing of the following components complete all as specified and directed :- LOCATION : LATIF (LT PANEL NO 03 & 04 )
1) Incomming:-
(a) Bus bars of alluminium strips of 250 Amp having current density not less than 130A/cm2 current rating capacity mounted on epoxy/FRP bus bar insulator - 01 set
(b) MCCB 160 Amps TPN 35/36 KA 415 Volts thermal megnatic release type having load adjustment setting 80% to 100% having Icu=Ics=100% - 01 Nos. (c) 3 phase voltmeter,ameter and power factor meter with necessary size of CT and internal wiring
(d) Indicating lamp set of 03 R,Y,B
2) OUT GOING
(a) MCCB 40 Amps TPN 16 KA 415 Volts thermal megnatic release type having load adjustment setting 80% to 100% having Icu=Ics=100% -07 Nos (b) MCB 32 Amps TPN 10 KA 415 Volts-01.
NOTE : (i) All outgoing feeder shall be connected with suitable size of bus bar. (ii) Bottom of LT Panel should be 600 mm above the ground level.
2
-
-
Supply, installation, testing and commissioning of LT Panel/Feeder Pillar box, three phase four wire, 415 Volts outdoor type, maufactured by CPRI approved manufacturer, free standing, floor mounting, double door, dust and vermin proof cubical type, fabricated out 3.15 MM CRCA sheet with anit corrosive coating and finally epoxy polyster powder coating of approved colour fully compartm- entalized design with 04 Nos of aluminiun bus suitable for 300 Amps having current density not less than 130A/cm2, pre-wired with suitable size of copper cable/insulated copper strip short circuit rating 50 KA (rms) for one second and frame & Legs made out 50 x 50 x 6 mm angle iron for LT panel fixed on and including PCC (1:3:6) foundation, bricks works in CM 1:4 duly plastered in CM 1:4 and necessary earth work etc. 4 nos lifting hook to be provided at top of panel, includinig supply and fixing of the following components complete all as specified and directed :- LOCATION : LATIF (LT PANEL NO 05 )
1) Incomming:-
(a) Bus bars of aluminium strips of 300 Amp having current density not less than 130A/cm2 current rating capacity mounted on epoxy/FRP bus bar insulator - 01 set
(b) MCCB 200 Amps TPN 25 KA, 415 V thermal megnatic type - 01 No. for incoming operated with extendable type rotory handle. (c) 3 phase voltmeter,ameter and power factor meter with necessary size of CT and internal wiring
(d) Indicating lamp set of 03 R,Y,B
2) OUT GOING
(a) MCCB 40 Amps TPN 16 KA 415 Volts thermal megnatic release type having load adjustment setting 80% to 100% having Icu=Ics=100% -09 Nos (b) MCB 32 Amps TPN 10 KA 415 Volts-01 nos.
NOTE : (i) All outgoing feeder shall be connected with suitable size of bus bar. (ii) Bottom of LT Panel should be 600 mm above the ground level.
1
-
-
Supply, installation, testing and commissioning of LT Panel/Feeder Pillar box, three phase four wire, 415 Volts outdoor type, maufactured by CPRI approved manufacturer, free standing, floor mounting, double door, dust and vermin proof cubical type, fabricated out 3.15 MM CRCA sheet with anit corrosive coating and finally epoxy polyster powder coating of approved colour fully compartm- entalized design with 04 Nos of aluminiun bus suitable for 1000 Amps having current density not less than 130A/cm2, pre-wired with suitable size of copper cable/insulated copper strip short circuit rating 50 KA (rms) for one second and frame & Legs made out 50 x 50 x 6 mm angle iron for LT panel fixed on and including PCC (1:3:6) foundation, bricks works in CM 1:4 duly plastered in CM 1:4 and necessary earth work etc. 4 nos lifting hook to be provided at top of panel, includinig supply and fixing of the following components complete all as specified and directed :- LOCATION : SAHU NC (LT PANEL 01)
1) Incomming:-
(a) Bus bars of alluminium strips of 1000 Amp having current density not less than 130A/cm2 current rating capacity mounted on epoxy/FRP bus bar insulator - 01 set
(b) MCCB 630 Amps TPN 35 KA, 415 V thermal megnatic release type having load adjustment from 80% to 100% having Icu=Ics=100% - 01 Nos. (c) 3 phase voltmeter,ameter and power factor meter with necessary size of CT and internal wiring
(d) Indicating lamp set of 03 R,Y,B
2) OUT GOING
(a) MCCB 125 Amps TPN 35/36 KA 415 Volts thermal megnatic release type having load adjustment setting 80% to 100% having Icu=Ics=100% -08 Nos (b) MCB 32 Amps TPN 16 KA 415 Volts-02 Nos
NOTE : (i) All outgoing feeder shall be connected with suitable size of bus bar. (ii) Bottom of LT Panel should be 600 mm above the ground level.
1
-
-
Supply, installation, testing and commissioning of three phase four wire, 415 Volts outdoor type factory made free standing floor mounting double door, dust and vermin proof cubical type, maufactured by CPRI approved manufacturer, LT Panel/Feeder Pillar box fabricated out 3.15 MM CRCA sheet with anit corrosive coating and finally epoxy polyster powder coating of approved colour fully compartmentalized design with 04 Nos of aluminiun bus suitable for 200 Amps having current density not less than 130A/cm2, pre-wired with suitable size of copper cable/insulated copper strip short circuit rating 50 KA (rms) for one second and 50 x 50 x 6 mm angle iron for making frame/Legs of LT panel fixed on and including PCC foundation with PCC(1:3:6) bricks works and necessary earth work etc. for lifting 4 hook should be provided at top of panel complete all as specified and directed with supply and fixing the following :- LOCATION : SAHU NC (LT PANEL NO 02, 03,04 ,05,06,07,08 )
1) Incomming:-
(a) Bus bars of aluminium strips of 200 Amp having current density not less than 130A/cm2 current rating capacity mounted on epoxy/FRP bus bar insulator - 01 set
(b) MCCB 125 Amps TPN 35/36 KA, 415 Vthermal megnatic release type having load adjustment setting 80% to 100% having Icu=Ics=100% - 01 Nos. (c) 3 phase voltmeter,ameter and power factor meter with necessary size of CT and internal wiring
(d) Indicating lamp set of 03 R,Y,B
2) OUT GOING
(a) MCCB 40 Amps TPN 16 KA 415 Volts thermal megnatic release type having load adjustment setting 80% to 100% having Icu=Ics=100% -08 Nos (b) MCB 32 Amps TPN 10 KA 415 Volts-01 Nos
NOTE : (i) All outgoing feeder shall be connected with suitable size of bus bar. (ii) Bottom of LT Panel should be 600 mm above the ground level.
7
-
-
Supply, installation, testing and commissioning of LT Panel/Feeder Pillar box, three phase four wire, 415 Volts outdoor type, maufactured by CPRI approved manufacturer, free standing, floor mounting, double door, dust and vermin proof cubical type, fabricated out 3.15 MM CRCA sheet with anit corrosive coating and finally epoxy polyster powder coating of approved colour fully compartm- entalized design with 04 Nos of aluminiun bus suitable for 1500 Amps having current density not less than 130A/cm2, pre-wired with suitable size of copper cable/insulated copper strip short circuit rating 50 KA (rms) for one second and frame & Legs made out 50 x 50 x 6 mm angle iron for LT panel fixed on and including PCC (1:3:6) foundation, bricks works in CM 1:4 duly plastered in CM 1:4 and necessary earth work etc. 4 nos lifting hook to be provided at top of panel, includinig supply and fixing of the following components complete all as specified and directed :- LOCATION : (SAHU 500KVA LT PANEL 01 )
1) Incomming:-
(a) Bus bars of aluminium strips of 1500 Amp having current density not less than 130A/cm2 current rating capacity mounted on epoxy/FRP bus bar insulator - 01 set
(b) ACB 1000 Amps TPN 65 KA, 415 V Micrprocessor type having L.S.I.G protection and trip display type with handle operated spring charging mechanism manual drawout type, having load adjustment from 80% to 100% having Icu=Ics=100% - 01 Nos . (c) 3 phase voltmeter,ameter and power factor meter with necessary size of CT and internal wiring
(d) Indicating lamp set of 03 R,Y,B
2) OUT GOING
(a) MCCB 160 Amps TPN 36 KA 415 Volts thermal megnatic release type having load adjustment from 80% to 100% having Icu=Ics=100% -09 Nos (b) MCCB 63 Amps TPN 16 KA 415 Volts thermal megnatic release type having load adjustment from 80% to 100% having Icu=Ics=100% -02 Nos
(c) MCCB 40 Amps TPN 16 KA 415 Volts thermal megnatic release type having load adjustment from 80% to 100% having Icu=Ics=100% -01 Nos
NOTE : (i) All outgoing feeder shall be connected with suitable size of bus bar. (ii) Bottom of LT Panel should be 600 mm above the ground level.
1
-
-
Supply, installation, testing and commissioning of LT Panel/Feeder Pillar box, three phase four wire, 415 Volts outdoor type, maufactured by CPRI approved manufacturer, free standing, floor mounting, double door, dust and vermin proof cubical type, fabricated out 3.15 MM CRCA sheet with anit corrosive coating and finally epoxy polyster powder coating of approved colour fully compartm- entalized design with 04 Nos of aluminiun bus suitable for 250 Amps having current density not less than 130A/cm2, pre-wired with suitable size of copper cable/insulated copper strip short circuit rating 50 KA (rms) for one second and frame & Legs made out 50 x 50 x 6 mm angle iron for LT panel fixed on and including PCC (1:3:6) foundation, bricks works in CM 1:4 duly plastered in CM 1:4 and necessary earth work etc. 4 nos lifting hook to be provided at top of panel, includinig supply and fixing of the following components complete all as specified and directed :- LOCATION : SAHU (LT PANEL NO 02, 03,04 ,05,06,07,08,09 )
1) Incomming:-
(a) Bus bars of alluminium strips of 250 Amp having current density not less than 130A/cm2 current rating capacity mounted on epoxy/FRP bus bar insulator - 01 set
(b) MCCB 160 Amps TPN 35/36KA, 415 V thermal megnatic release type, having load adjustment from 80% to 100% having Icu=Ics=100% - 01 Nos. (c) 3 phase voltmeter,ameter and power factor meter with necessary size of CT and internal wiring
(d) Indicating lamp set of 03 R,Y,B
2) OUT GOING
(a) MCCB 40 Amps TPN 16 KA 415 Volts thermal megnatic release type 80% to 100% having Icu=Ics=100% -01 Nos
(b) MCB 32 Amps TPN 10 KA 415 Volts-02 Nos
NOTE : (i) All outgoing feeder shall be connected with suitable size of bus bar. (ii) Bottom of LT Panel should be 600 mm above the ground level.
8
-
-
Supply, installation, testing and commissioning of LT Panel/Feeder Pillar box, three phase four wire, 415 Volts outdoor type, maufactured by CPRI approved manufacturer, free standing, floor mounting, double door, dust and vermin proof cubical type, fabricated out 3.15 MM CRCA sheet with anit corrosive coating and finally epoxy polyster powder coating of approved colour fully compartm- entalized design with 04 Nos of aluminiun bus suitable for 1500 Amps having current density not less than 130A/cm2, pre-wired with suitable size of copper cable/insulated copper strip short circuit rating 50 KA (rms) for one second and frame & Legs made out 50 x 50 x 6 mm angle iron for LT panel fixed on and including PCC (1:3:6) foundation, bricks works in CM 1:4 duly plastered in CM 1:4 and necessary earth work etc. 4 nos lifting hook to be provided at top of panel, includinig supply and fixing of the following components complete all as specified and directed :- LOCATION : (SAHU 500KVA NO 02 LT PANEL 01 )
1) Incomming:-
(a) Bus bars of alluminium strips of 1500 Amp having current density not less than 130A/cm2 current rating capacity mounted on epoxy/FRP bus bar insulator - 01 set
(b) ACB 1000 Amps TPN 65 KA, 415 V Micrprocessor type having L.S.I.G protection and trip display type with handle operated spring charging mechanism manual drawout type, having load adjustment from 80% to 100% having Icu=Ics=100% - 01 Nos . (c) 3 phase voltmeter,ameter and power factor meter with necessary size of CT and internal wiring
(d) Indicating lamp set of 03 R,Y,B
2) OUT GOING
(a) MCCB 160 Amps TPN 35/36 KA, 415 Vthermal megnatic release type having load adjustment setting 80% to 100% having Icu=Ics=100% - 10 Nos. (b) MCCB 63 Amps TPN 16 KA, 415 Vthermal megnatic release type having load adjustment setting 80% to 100% having Icu=Ics=100% -01 Nos.
(c) MCCB 40 Amps TPN 16 KA, 415 Vthermal megnatic release type having load adjustment setting 80% to 100% having Icu=Ics=100% -02 nos
NOTE : (i) All outgoing feeder shall be connected with suitable size of bus bar. (ii) Bottom of LT Panel should be 600 mm above the ground level.
1
-
-
Supply, installation, testing and commissioning of LT Panel/Feeder Pillar box, three phase four wire, 415 Volts outdoor type, maufactured by CPRI approved factory, free standing, floor mounting, double door, dust and vermin proof cubical type, fabricated out 3.15 MM CRCA sheet with anit corrosive coating and finally epoxy polyster powder coating of approved colour fully compartm- entalized design with 04 Nos of aluminiun bus suitable for 250 Amps having current density not less than 130A/cm2, pre-wired with suitable size of copper cable/insulated copper strip short circuit rating 50 KA (rms) for one second and frame & Legs made out 50 x 50 x 6 mm angle iron for LT panel fixed on and including PCC (1:3:6) foundation, bricks works in CM 1:4 duly plastered in CM 1:4 and necessary earth work etc. 4 nos lifting hook to be provided at top of panel, includinig supply and fixing of the following components complete all as specified and directed :- LOCATION : SAHU (LT PANEL NO 02, 03,04 ,05,06,07,08,9 ,10)
1) Incomming:-
(a) Bus bars of alluminium strips of 250 Amp having current density not less than 130A/cm2 current rating capacity mounted on epoxy/FRP bus bar insulator - 01 set
(b) MCCB 160 Amps TPN 35/36 KA, 415 V thermal megnatic release type having load adjustment setting 80% to 100% having Icu=Ics=100% - 01 Nos. (c) 3 phase voltmeter,ameter and power factor meter with necessary size of CT and internal wiring
(d) Indicating lamp set of 03 R,Y,B
2) OUT GOING
(a) MCCB 40 Amps TPN 16 KA, 415 Vthermal megnatic release type having load adjustment setting 80% to 100% having Icu=Ics=100% -08 Nos. (b) MCB 32 Amps TPN 10 KA 415 Volts-01 No.. NOTE : (i) All outgoing feeder shall be connected with suitable size of bus bar. (ii) Bottom of LT Panels should be 600 mm above the ground level.
9
-
-
Dismantling and taking down old LT Panel board/Capacitor panel board
complete with all accessories including dismantling PCC foundation and making good the surface complete all as specified and directed
15
-
-
M&L in repair for earthing with GI earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to and including GI earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion and excavation and earth work in any type of soil, charcoal dust common salt, PCC 1:3:6 type C1 in chamber, precast RCC cover 50mm thick in cement concrete 1:2:4 type B1 reinforced with welded steel wire fabric or XPM (Weight not less than 4 Kg/Sqm) with two handle 12mm dia bar with cast iron funnel with wire mesh, 20mm bore GI pipe medium grade watering pipe, lugs, 50mm bore GI pipe medium grade protection pipe upto 7.5m complete all as specified and directed
Note: (i) Item includes the cost of 7.5 metre earth strip and GI pipe for protection of earth strip. Any additional length shall be paid seperately. (ii) Ontesting after completion, if the desired earth resistance is not obtained, the earthing will be redone at no extra cost by the contractor
104
-
-
Supply and fixing automatic street light timer using nature switch for automatic switching of street light based on LUX level of natural light .The sensor (nature switch ) along with suitable power contactor, MCB and support terminal should be enclosed in pole/wall mountable enclosure made of rust proof ,electric shock proof ,termite proof and FF grade SMC junction box (sintex or equivalent make) confirming to IP 54 suitable for three phase phase of 12KW complete all as specified and directed
Make -Nature switch: -Swadeep -02EC25kW3P or equivalent in legrand/siemens
19
-
-
S&F in LT Feeder Pillar ( Kiosk )of suitable made out 3 mm thick out door type CPRI approved) with openable Front door including locking arrangement with Copper Busbar 250 amps rating with MCCB 125 Amps 4pole 16KA thermal megnatic adustable type for incoming and fixed on angle iron frame and PCC plinth complete all as specified and directed
11
-
-
Supply, fixing & connecting in repair of FRLS PVC insulated twin core 2.5 Sqmm unsheathed multistranded copper conductor complete all as specified and directed
4800
-
-
M & L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending colt or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint.
9
-
-
Schedule of Credit Rs. 4,22,470.00
-
-
-
Signature of Contractor
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%