Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 50,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_667559_3Tender No
CA No CWE BKN-Token No 31/2024-2025Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Removing excavated soil/material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and as directed.
112
-
-
M&L for dry sand (Local Tibba sand) and punning for cushioning and cover for protection of under ground electric cable complete all as specified and as directed.
Notes : (i) Approved local Tibba dry sand free from vegetations, grass and other deleterious substances shall be used. (ii) For the purpose of payment, only punned thickness shall be measured.
45
-
-
Supplying and laying factory made, un-reinforced precast concrete cable cover, ISI marked, Class HV, Type 1, flat, size 300mm x 180mm x 40mm, laid as cable protection cover in trenches, complete all as specified & as directed.
2250
-
-
Supply, laying, jointing and testing HT XLPE (cross linked polyethylene) insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium stranded conductor 11000 Volt (Earthed) grade of cross sectional area 150 Sqmm, 3 Core (ISI marked) laid in trenches/ducts, through pipe, under floors or roads/ along poles etc, including dismantling & taking out old unserviceable HT cable, complete all as specified & as directed.
Notes :- (i) Sand cushioning, cable protection, GI protection pipe, jointing kits and excavation & earth work shall be measured & paid for separately.
(ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
100
-
-
All as per serial item No 7.00 here-in-before but of size 95 Sqmm 3 Core complete all as specified & as directed.
510
-
-
M&L for cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed.
4
-
-
M&L for cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 150 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed.
3
-
-
M&L for cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed.
6
-
-
M&L for cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 150 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed.
4
-
-
Testing and fault locating of HT undergroung cable with the help of cable fault locator machine at site including removal of moisture content from cable complete all as specified and directed. (Note:- The machine for locating of fault will be arranged by the contractor .The quoted rate is included for the fault locating machine. Necessary excavation, earthwork etc measured and paid separately under Sch 'A').
15
-
-
M&L for cleaning, removing dust, pigeon poo and other foreign materials on external surface of VCB with required chemical and rubbing by micro amren paper and making surface rust free and aesthetic look complete all as specified and directed.
27
-
-
M&L for Boring of holes under road, pavement, hard standing, etc by trench less technology using necessary machine / manually without disturbing the top surface suitable for passing the GI protection pipe / cables, complete all as specified and as directed.
20
-
-
M&L for Galvanized iron tubing, 80mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of HT electric cable including taking down old unserviceable protection pipe with clamps complete all as specified & as directed.
Note :- Excavation & earthwork shall be measured & paid for separately.
12
-
-
M&L for Galvanized iron tubing, 100mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of HT electric cable including taking down old unserviceable protection pipe with clamps complete all as specified & as directed.
Note :- Excavation & earthwork shall be measured & paid for separately.
12
-
-
S&F Switch air break, gang operated outdoor, Horizontal operated type, HT 11 KV, Triple pole, 200 Amps, 9 insulator suitable for horizontal mounting fixed contacts of phosphorous bronze and moving contacts of copper, manually operated from ground level with operating mechanism including GI tubing medium grade 32mm bore operating rod, pad locking arrangements, MS arcing horns, flexible braiding earthing blades, rod and contacts without drop out fuse assembly and jumpers with Mink conductor line, taps, clamps, colour coated HT sleeves and fittings suitable for vertical mounting, fixed in repairs, complete all as specified and as directed.
2
-
-
S&F Drop out expulsion fuse assembly with fuse carrier, triple pole, HT 11000 Volts, 25 Amps, outdoor type (having two Nos post insulator mounted on MS channel for each pole) and jumpers with conductors line taps, clamps, colour coated HT sleeves and fitting, fixed in repairs, complete all as specified and as directed.
1
-
-
Repairs to existing two/ three/Four pole gang operated air break switch horizontal/vertical throw incl taking down old unsv male/female contact set and providing in replacement new male female contact set copper with silver coated ,spring loaded suitable for 400 Amps complete with jumpers from GOD to OH line & DO to GOD complete with thimbles incl HT tape reqd for repairing HT end termination joint complete all as specified and directed.
7
-
-
Surface dressing not exceeding 15cm deep in soft/loose soil if required and clearing away all grass vegetation, saplings, shrubs, brushwood, undergrowth, roots, and trees not exceeding 30 cm girth (measured one metre above ground level) surrounding Transformers, 02 Pole structures, 04 Pole Structures, 33/11 KV structure etc at various sub stations / E&M installations and removing rubbish upto a distance not exceeding 50m outside the periphery of the area under clearance complete all as specified & as directed.
5500
-
-
M&L for preventive maintenance / repairing by opening and taking out the Vacuum Circuit Breaker (VCB) 11/33 KV 630 Amp, type VMX from panel and carry out the general maintenance such as oiling & greasing the mechanical parts, motor, gear, lever spring, operating rod, cleaning the female contacts, tightening of nuts and bolts, cleaning the male and female contact of panel, oiling the bus bar shutter, checking the AC/DC wiring, circuit including control fuses and circuit jack, on/off push button, indicating lamp, voltmeter, ammeter, PF meter, replacement of minor parts (where required) and testing after re-inserting the VCB in panel complete all as specified & as directed. The new replaced parts shall be measured and paid separately under appropriate item of Sch 'A' as "Supply Only"
31
-
-
Supply only Electro mechanical Master trip relay Hand reset type Suitable for flush mounting, in temp 0 to 55°C, RH 50% to 100%, 1A & 5A CT input and auxuliary DC supply of 30/110/220 Volt complete all as specified and directed.
4
-
-
Supply only Over current and earth fault relay Suitable for flush mounting, in temp 0 to 55°C, RH 50% to 100%, 1A & 5A CT input and auxuliary DC supply of 30/110/220V with breaking capacity 2 KVA complete all as specified and directed.
7
-
-
Supply only Trip Circuit supervision Relay as existing Make :Alstom Model: VAX 31 complete all as specified and directed.
2
-
-
Supply only Anti Pumping Relay should not be plug in type & should have suffcient number of contact complete all as specified and directed.
5
-
-
Supply only alarm Annunciator enclosed in ABS enclosures with high strength for11 KV VCB panel Consists of 2 relays Trip relay (C-NC-NO),Alarm Relay (C-NC-NO), 04 window Annunciator with dual power supply (AC or DC) complete all as specified and directed.
2
-
-
Supply only Electronic hooter having similar specification & bezel size 96x96mm as per existing Make : Stelmec having model No. SLA74 complete all as specified and directed.
2
-
-
Supply only Tripping coil having copper material through actuating device rated for Substation DC voltage 12/ 24 /110 V ,burden value 200 watt , Min operating Voltage of 70% for tripping and 85% for closing operation as per existing installed on site complete all as specified and directed.
8
-
-
Supply only Closing coil having copper material through actuating device rated for Substation DC voltage 12/ 24 /110 V ,burden value 200 watt,, Min operating Voltage of 70% for tripping and 85% for closing operation as per existing installed on site complete all as specified and directed.
8
-
-
Supply only Resin cast/Dry type Potential transformer having 3 phase,Ratio 11000/√3V / 110√3V,vector group Star/Star with neutral earthed, burden/class: 100VA/0.5, Fixed type with HRC fuse protection, with IS: 3156-1992 complete all as specified and directed.
2
-
-
Supply only Resin cast, Dual ratio, Indoor type Current Transformer for breakers having ratio 100-50/5-5A, Burden value 15VA both for protection & metering core, Short-time circuting rating 25kA for 3 sec , Protection Core 5P10 complete all as specified and directed.
3
-
-
Supply only HT vaccum interrupted assembly bottle with flex connection suitable for VMX type VCB 630 Amps capacity for RYB phases complete all as specified and as directed.
3
-
-
Supply only Spring charging motor operated on Power 150-250 Watts ,220 V AC/DC supply having insulation Class B type complete all as specified and directed.
8
-
-
Supply only VCB trolly rack out Gear complete all as specified and directed.
1
-
-
Supply only Handcart chasis truck VCB trolly for withdrawable vaccum circuit breaker of 650 mm to 800 mm width size complete all as specified and directed.
1
-
-
Supply only Spring charging Handle for Hand operating complete all as specified and directed.
4
-
-
Supply only PT/VT fuse 11/12 KV,breaking capacity 45 kA, rating 3.15 Amp complete all as specified and directed.
15
-
-
Supply only Power pack fuse 1 to 5 Amp complete all as specified and directed.
1
-
-
Supply only HRC fuse link type NSD type rating 02 Amps to 10 Amps, Rated voltage 550 Volt, breaking capacity 80 KA as per IS 13703 latest complete all as specified and directed.
20
-
-
Supply only HRC fuse link type NSD type rating 16 Amps to 32 Amps, Rated voltage 550 Volt, breaking capacity 80 KA as per IS 13703 latest complete all as specified and directed.
15
-
-
Supply only Fuse fitting (front+back+busbar) for LV BS (NSD) type of Fuse FA 20 Amps, Rated voltage 500 V as per IS 13703 latest complete all as specified and directed.
10
-
-
Supply only Space Heaters Thermostat having temp range 25-85°C complete all as specified and directed.
8
-
-
Supply only Auxillary switch for suitable for 11 KV breaker complete all as specified and directed.
6
-
-
Supply only Local Remote Selector Switch complete all as specified and directed.
12
-
-
Supply only Breaker control Switch Three position : Trip, close and neutral control switch with one trip and one close 32 Amp for operation of VCB complete all as specified and directed.
10
-
-
Supply only Standard push button, flush round head 22 mm dia and required number of N/O & N/C self returning contacts without locking arrangements for Emergency Trip functions bracket assembly complete all as specified and directed.
8
-
-
Supply only Emergency stop push button switches, Flush round Head 22 mm dia and required number of N/O & N/C self returning contacts without locking arrangements for Emergency Trip functions bracket assembly complete all as specified and directed.
5
-
-
Supply only Claster LED type Indicating lamps with built resistor holder and coloured lens with rating 30/110/220 Volt DC complete all as specified and directed.
20
-
-
Supply only Digital VAF + Power factor meter 3 phase,three element 4 wire, inbuilt CT 5 Amp , voltage 110/230/440 Volt having 4 Digit LED with auxiliary supply 230 Volt AC, Class 0.5 complete all as specified and directed.
4
-
-
Supply only Digital Multi function meter or load manager of size 96x96 mm AC 3 Phase(inbuilt selector switch), Low starting current 6mA (for LG) 50mA (for MicroG) Auxillary supply 230 Volt AC, 3 line display having range 5-5000 mA Accuracy class 0.5S complete all as specified and directed.
7
-
-
Supply only Digital Ammeter 96x96 mm AC 3 Phase (inbuilt selector switch),Auxillary supply 230 Volt AC, 3 line display having range 5-5000 Amp complete all as specified and directed.
9
-
-
Supply only Digital AC voltmeter 96x96mm AC Range 0-15 KV, Accuracy 1.0 PTR 11KV/110 Volt, Auxillary supply 230 Volt AC, 3 line display complete all as specified and directed.
9
-
-
M&L for testing and adjusting the following relay including checking and rectifying the tripping circuit complete, Calibration of relay for 11 KV VCB at various place complete all as specified and directed.
(a) Trip circuit supervision Relay
(b) Master Trip Relay, 24 DC
(c) Over current & earth fault relay
(d) Intelligent Panel Meter (e) Ammeter & Voltmeter
Note:- (i) The tripping system of relays are to be calibrated with MRS,kanasar
(ii) The tripping timing of the relay to be adjusted less than 33KV system at MRS Kanasar (iii) The testing instrument whatever required to test the relays will be arranged by the contractor at his own cost. (iv) The test shall be provided from authorized agency.
31
-
-
Supply and fixing in replacement of battery backed power pack having input 110 or 230V AC, output 24/110/220 Volt DC and continous load 100 VA as per IEC 60947-1 & IEC 61000-4/5 complete all as specified and directed.
12
-
-
M&L for cable route indicator made of Jodhpur stone of finished size 120cm x 20cm x 8cm with round top and all finished surfaces duly marked with ‘HT’ lettering of size 6cm x 6cm engraved on two sides of the stone and letters painted with thick synthetic enamel paint of suitable colour including necessary excavation & earthwork complete all as specified and as directed.
Notes : (i) These shall be fixed along the route of cable at 50 meter interval & on every turning & cable joint as directed.
390
-
-
M&L for preparation of old painted surface of 11 KV VCB installed at Kanasar cantt area by using coarse cloth/sore brush and painting with one coat of synthetic enamel light grey paint with the help of spray gun, including writing SM No./MES No. with paint on black base complete all as specified and as directed.
10
-
-
Supplying, installing, testing and commisioning of 350 KVAR (01x100 KVAR Capacitor Bank + 03x50 KVAR Capacitor Bank + 01x100 KVAR SVG) hybrid dynamic reactive power factor correction panel for 11 KV, Outdoor type with canopy on top, IP 55, Aluminium busbar-0.8 A/sqmm current density, Front & rear acess, Sheet metal CRCA, Sheet thickness min 3mm for panel, 3mm for gland plate, floor or plinth mounting, base frame, ISMC 75x40x5mm and bus bar having material E91E Grade Aluminium, phase 80x10x01 Nos, Neutral 40x10x01 Nos, Earth 20x10x01 Nos or equivqlent with control wiring and power wiring as per standard complete all as directed and specified with following specification:-
(a) INCOMER Feeder :- ICT step relay, 630 Amp, 36 KA TP+NL MCCB, thermal magnetic release with O/L & S/C protection, extended rotary handle and spreader link for above MCCB, HMI,CT-630/5A,10VA, CL-1, Nylon casing type for metering, CT shorting link, 8 Inch cooling fan with filter with dust guard, thermostat & space heater of min 100 watt, Panel lamp with door limit switch with 1NO+1NC, 02A SP MCB 'C' curve for control supply, neutral & CT shorting link complete.
1
-
-
(Description of serial item No. 58.00 Contd….)
(b) 100 KVAR Capacitor Bank Feeder No.1 :- 250 Amp, 25 KA TP MCCB, thermal magnetic release with O/L & S/C protection, extended rotary handle and spreader link for above MCCB, 06 Amp SP control MCB, Auto/manual selector switch 6 Amp, 100 KVAR TSM switching module, 100 KVAr, 440 volts, 7% detuned, 180% linear, Copper wound series reactor, 66.2 KVAR (33.1*2) 525 volts ultra heavy duty square type capacitor bank with compatible contactor - 01 Nos
(c) 50 KVAR Capacitor Bank Feeder No.2,3&4 :- 125 Amp, 25 KA TP MCCB, thermal magnetic release with O/L & S/C protection, extended rotary handle and spreader link for above MCCB, 06Amp SP control MCB, Auto/manual selector switch 6Amp, 50 KVAR TSM switching module, 50 KVAR, 440 volts, 7% detuned, 180% linear, Copper wound series reactor, 66.2 KVAR (33.1*2) 525 volts ultra heavy duty square type capacitor bank with compatible contactor - 03 Nos
(d) 100 KVAr SVG Feeder No :- 250 Amp, 25 KA FP MCCB, thermal magnetic release with O/L & S/C protection ,extended rotary handle for above MCCB,100 KVAR SVG Module.-01 No
(Note:- The PCC foundation, bricks work and plinth related items rate is also included in quoted rate of this item.)
-
-
-