Jaipur Development Authority Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 4,47,540Document Cost
₹ 1,000Tender Fee
₹ 2,000
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_JDAJP_393704_1Bid Award Id
ViewTender No
EE (ELECT-II)/01/2023-24Tender Authority
Jaipur Development Authority ViewPurchaser Address
-Website
http://jda.urban.rajasthan.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Electrification of JDA Residential scheme Khasra number 3 Village Niwaru JDA Jaipur.
BOQ Items
6.4 mm thick
0.3
213
712.8
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. Complete Rate Group-1
-
-
-
3 x 2.5 sq.mm
120
5760
48
Supplying and fixing of Aluminium / Copper bus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. Complete Rate Group-1
-
-
-
Electrolytic grade Aluminium bus bar
2
672
336
P & F of ac operated heavy duty 230 /440 Volt power contactor conforming to IS:13947-4-1/IEC:947-4-1 having provision of mechanical interlocking, auuxilary contacts, Din rail mounting type including making connections, testing etc. as required. Complete Rate Group-1
-
-
-
100 A, 4 pole Power contactors with following AC 1 Rating
1
4595
4595.2
SF of 110/220 V, LED (22.5 mm dia ) Indicating lamp with integral circuit, terminal block, including connection etc. as required. Complete Rate Group-1
-
-
-
Red/yellow/Green colour
3
360
120
SITC of quick make and quick break 4 POLE current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip ,earth fault trip, push (test) to trip , including making connections with lugs & spreaders, etc. as required.
-
-
-
With Thermal Magnetic release, up to 100 Amp , 16 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu
1
4640
4640
P&F of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming etc. as required. Complete Rate Group-1
-
-
-
One day & week reserve (digital type )
1
4596
4596.8
P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size.
-
-
-
25.0 Sq.mm 3.5 core Complete Rate Armoured
250
41600
166.4
185.0 Sq.mm 3.5 core Complete Rate Armoured
755
553868
733.6
Pipe Earthing as per IS:3043 with perforated 3.0 Mtr. Long, 40 mm dia. ' B ' class G.I. Pipe including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300 mm and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance as required.
2
2640
1320
P & Laying XLPE insulated IS:7098/II/85 of Group1 and approved make H.T.cable for working voltage 11 K.V.Earthed direct in ground including excavation of 30cmx100cm size trench, 25cm layer of river sand, IInd class bricks covering, refilling earth, compaction of earth, making necessary connection testing etc.as required of size. Complete Rate Group 1
-
-
-
3 core 185.0 Sq.mm
13800
13976640
1012.8
Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit of Group1 and approved make suitable for XLPE insulated 11 KV / 33 KV cable, with required components, prepration of cable ends,testing etc. as required of following sizes .
-
-
-
11 KV End Termination Kit Outdoor type 3 core 120/150/185/225 Sq.mm Complete Rate Group 1
56
291200
5200
11 KV Straight Through Joint Kit 3 core 120/150/185/225 Sq.mm Complete Rate Group 1
55
660000
12000
Supply and installation of spike of M.S. rod 20mm dia 3.0mtr. long for earthing of (tower/pole) drive into earth by mechnical means sturcture connection the spike with cross arm top hamper PCC pole, lattics tower to earth etc. complete as per technical specification of DISCOM Complete Rate Group 1
61
31720
520
S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required.
-
-
-
8 SWG G.I. ( Hot Dipped ) Wire Complete Rate group-I
282
2030
7.2
S & Laying following size‘ B ‘ class G.I. Pipe confirming to IS : 1239 P - 1 (1990) with accessories for laying earth conductor/strip / cable in ground/surface/recess as required
-
-
-
125 mm dia. Complete Rate group-I
984
728160
740
Supply and fixing 11kV Disc insulator (IS 731/ 1971) with minimum creepage distance of 300mm on existing bracket including all accessories like hot dipped GI spindle and nuts etc (as per specificationof Discom).
-
-
-
B & S type hardware 45 KN
18
8064
448
B & S disc insulator 45 KN
18
5846
324.8
Supply and fixing double pole structure for 11/0.4 Kv substation as per Discom specification complete in all respect as required including nuts and bolts etc (excluding the cost of poles) made of MS channel of 4 nos 100 x 50 x 6mm and 4 nos 75 x 40 x 6mm and MS flat 50 x 6mm as per Discom specifications.
6
45936
7656
Supply and erection of P.C.C./R.C.C. pole as per REC manual no 15/1979 conforming to IS: 2905/1966 including excavation of pit and back filling with stone aggregate/boulders and soil in 0.45m consolidating each deposited layer of 0.45m by ramming and watering etc complete in all respect.
-
-
-
9.0 Mtr long (200 Kg) as per Discom specification Complete Rate Group 1
76
234639
3087.36
P & F of IP 65 protected LED Street Light Luminaire on existing brackets. Fixture made of powder coated single piece pressure die cast aluminium housing with heat dissipation fins on housing with UV stablized PC/ Toughened glass cover and lens/ reflector. Input power (including driver loss) range from 20-25W/30-40W/80-90W/ 110-120W with luminous Efficacy 80 Lumen/W (warm white) & 85 lumen/W (cool white) (As per LM79). LEDs of Cree/Nichia/OSram/Philips make is to be used at 1W/2W per LED, CRI 70 and CCT 2700 K - 6500K. The integral SMPS based electronic driver must have efficiency 85%, Power factor 0.95, THD 20% and input Voltage range of 90-270 VAC at 50 Hz. System life of 25000 Burning Hours with 70% of initial Lumens maintained. Fixtures must be in compliance with IS/CE Standards. Approved make : Philips, Bajaj, Surya. Complete Group-1
-
-
-
IP - 65 Protected LED Street Light Luminaire, LED Street Light fixture 30-40 Watt
60
422400
7040
P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections, testing etc. as required. Complete Rate Group-1
-
-
-
Four Pole MCB, 40A to 63A rating
2
2204
1102.4
Supply and erection of GI stay set as per Discom specification complete with long stay rod with anchor plate including stay clamps turn buckle and G.I stay wire tightened through strain insulator, in cement concrete 1:3:6 including excavation of pit-re-filling etc as reqd. Stay set of dia 16mm,1.8m long stay rod and anchor plate 300x300x6.4mm Complete Rate Group 1
12
7536
628
Supply and fixing of following LT Supporting accessories with nut bolt & Clamps made out as per standard Discom‘s specifications.
-
-
-
LT cross arm 600 mm long with clamp Complete Rate Group 1
56
12544
224
LT cross arm 1200 mm long with clamp Complete Rate Group 1
56
21504
384
Supply and fixing of LT porcelain pin insulator as per IS 1445-1997 suitable for working voltage 1100 volts including all accessories like hot dip GI forged spindle of 260mm long and nuts etc as reqd as per Discom specification. 105mm x 80mm Complete Rate Group 1
250
13000
52
Supply and fixing of porcelain shackle insulator as per IS:1443 1979 suitable for working on 1100 volts including hot dipped GI accessories and heavy duty hardwares etc as required as per Discom specification. 100mm x 110mm Complete Rate Group 1
270
25920
96
Supply and fixing of ‘V‘ type cross arms made of MS channel on the existing poles complete including all necessary nut and bolt etc with clamps as per Discom specification. 11kV cross arms (75 x 40 x 6.8 kg/mtr) Complete Rate Group 1
12
8160
680
Supply and fixing of top hamper on the existing pole complete including nut bolts etc as required.
-
-
-
Vertical type, 11 kV (.7m long) (65 x 65 x6mm angle)
12
3024
252
Supply and fixing of Cross arms made out from 100 x 50 x 5 mm MS channel complete in all respect as required including nuts and bolts and clamp as per Discom specification etc as required. 1.3 m long Complete Rate Group 1
4
2720
680
Supply and fixing 11kV pin insulator( IS 731/ 1971) with minimum creepage distance of 300mm on existing bracket including all accessories like hot dipped GI spindle and nuts etc (as per specificationof Discom). Complete Rate Group 1
48
5184
108
SITC of Cutting back up surface up to 2 Mtr. Depth by digging by Bogi including all layers of crust for laying pipe line etc. and making good to original condition (excluding cost of bitumen)
12500
3600000
288
Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt, Painting etc. as required. Complete Rate Group-I
300
20160
67.2
Supplying and drawing overhead steel core Aluminium conductor (ACSR) ISI marked(IS 398 part II-1996) on existing cross arms through insulator with all necessary T&P required including binding and twisting etc. complete in all respect as required as per Discom specification.
-
-
-
100 sqmm of (6/4.72 mm+1/1.57 mm) (Dog)
400
28480
71.2
50 Sqmm of (6+1) 3.35 mm (Insulated Rabbit), Complete Rate Group 1
9580
475168
49.6
Supply and fixing of piller box made of 2 mm thick powder coated CRCA sheet of 415 volts 3 phase 4 wire triple pole and neutral type, complete in all respect as required. Including knife switch of 400 amp. rating , HRC fuses with copper one piece U contacts base, brass studs and nuts, copper busbar for main and interconnection, MS angle frame of 50 x 50 x 6 mm grouted with C.C. of M-10 grade to achieve the height of 1.5 feet above the road level suitable for four outgoing.
4
136000
34000
Supply and fixing of 11kV, 400 Amp 3pole, central pot rotating double break type isolator (IS:9921 part I toV) without earth blade operating mechanism with GI spring loaded reverse loop type fixed contact, solid hard drawn electolytic copper tubular moving contact with silver/ nickel plated at end points, 9 nos post insulator of 12 kV (IS:2554 & IS 5350 part III), hot dipped galvanising hard ware, nut, bolts etc complete in all respect as per specification of Discom.( Type tested by ERDA/CPRI.)
25
263000
10520
Supply and fixing 100 Amp, 11kV Horn gap fuse set IS 9385 on existing DP structure with 6 nos 24kV/22kV post insulator (IS:5350 part III), hot dipped hard ware,fuse wire of required size etc. complete in all respect as per specification given by Discom. (Type tested by ERDA/CPRI)
6
29040
4840
Supplying and making end termination with heavy aluminium lugs ( Pin / ring type ) duly crimped with crimping tool, PVC tape etc of following size. 150.0 Sq.mm
212
6444
30.4
Supply and erection of 7.5 Mtr. "AB-1" type sub-station structure fabricated from M.S. Angle 65 × 65 × 6 mm with bracing of M.S. Flat 50 × 6 mm including excavation of pits of size 1 × 1 × 1.25 meter (as per specification & drawing approved by Nigam) Steel Wt. 350 Kg. Each structure.
4
76000
19000
S I T C of BEE 3 star rated Aluminium wound Transformer conforming to IS: 2026 & Losses as per Discom's CTL ( CTL Test certificate to be attached ) of rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11, standard accessories like conservator, silica gel breather, radiator, fins, HT bushing & LT cableboxes, Off -LTC (+/- 5% in steps of 2.5%) winding temperature rise of 50/55 C, ISI marked drain valve, Dial type Temperature gauge, first fill of oil, Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer. ( See table - 08 for CTL Losses )
-
-
-
100 KVA
4
598400
149600
S & F of Street light bracket made out from following size of ' B ' class GI pipe with heavy duty pole clamp, Saddles suitable fastners etc. as required.
-
-
-
25 mm Dia.
60
10560
176
Dismentling/Removing of power line materials collecting from site and depositing the same with AEN office/ store. Refilling pits in compaction, leveling etc. GI wire, stay wire etc. shall be bounded in the shape of coils, if any material is damaged during Dismentling/ transportation replacing/repairing shall be on the part of contractor
-
-
-
PCC Pole
22
3410
155
ACSR Weasel/Rabiit conductor
1800
1260
0.7
11KV cross arm
22
270
12.3
11 KV Top Hampars
22
220
10
11KV disc insulators
24
108
4.5
11KV disc H/W
24
114
4.75
11KV pin insulators
66
231
3.5