Water Resources Department Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 24,083Document Cost
₹ 2,000Tender Fee
₹ 1,421
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_WR_126411_2Bid Award Id
ViewTender No
03/2024-2025 dated 30.08.2024Tender Authority
Water Resources Department ViewPurchaser Address
-Website
http://eproc.punjab.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Providing and fixing chicken mesh for brick work and RCC junction of galvanized low carbon wire, annealed wire of diametre 0.6 to 2.0mm distance between the faces of the hexagon 13 to 50mm complete in all respect.
151.76
-
-
12.5mm thick cement plaster 1:4
604.89
-
-
Scrapping of white wash & colour wash
327.92
-
-
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
932.81
-
-
Applying priming coat with cement primer in all shades on newly plastered or
concrete exterior surface
932.81
-
-
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade
712.63
-
-
finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @2.20Kg/10Sqm
349.6
-
-
Wiring fan point without fan box ( inPVC insulated copper conductor single core FRLS cable(ISI marked) overall 1.5 sq. mm, 1100volts grade with steptype electronic fan regulator 100watts.
6
-
-
Wiring fan point with fan box ( inPVC insulated copper conductor single core FRLS cable(ISI marked) overall 1.5 sq. mm, 1100volts grade with steptype electronic fan regulator 100watts
4
-
-
Wiring light point in PVC insulated copper conductor singlecore FRLS cable (ISI marked) overall 1.5 sq. mm,1100volts grade.
15
-
-
Wiring call-bell point in PVC insulated copper conductorsingle core FRLS
cable (ISI marked) overall 1.5 sq. mm,1100volts grade with bell push and electronic buzzer 230volts AC (including the cost of bell push, electronic buzzer& powder coated concealed metal box for electronic buzzer
4
-
-
Wiring 3 pin 6 Amp. wall socket (Shuttered) point in PVCinsulated copper
conductor single core FRLS cable (ISImarked) overall 1.5 sq. mm, 1100volts grade completewith bonding to existing earth with PVC insulated copperconductor single core FRLS cable (ISI marked) overall 1sq. mm, 1100volts grade.
20
-
-
MCB Single Pole 6-32amp. (10kA, Curve-C)
12
-
-
MCB Four Pole 50, 63amp. (10kA, Curve-C)
1
-
-
Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO‘s/ RCCB‘s in the distribution board (For SP&N distribution board with provision DP MCB‘s/ RCCB‘s/ RCBO‘s as incomer and SP MCB‘s as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB‘s/ RCCB‘s/ RCBO‘s as incomer and SP MCB‘s as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-
TP&N Vertical Double Door Distribution Board 4 way each
1
-
-
Supply and erection of On Load Change over Switch with advance neutral UNIT in sheet enclosure on the existing surface.(Confirms to IS 13947
(Part-3). complete with G.I. Bolts, Nuts etc. according to the size of holes in the body of the enclosure & Connections on both sides of switch with suitable size of thimbles as per PWD General Specifications:- On Load Change Over Switch Four Pole 100amp., 415volts (With Sheet Enclosure)
1
-
-
Porcelain Fuse Unit 63Amp., 415volts
3
-
-
Doors of area 3 sqm and below.
6
-
-
Windows of area 3 sqm and below
4
-
-
Clerestory windows of area sqm and below.
1
-
-
Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete: 300mm x 16mm
10
-
-
Factory manufactured solid flush door fixed in position iron hinges, etc (excluding
the cost of any fittings other than specified above but including labour for
fixing the same in position (Code : IS 2202-1(1999) Commercial with elm or
gurjan facing on both\ Sides with laminated core and lipped edges:- 35mm Thick
18.05
-
-
Panelled, glazed or glazed and panelled.35mm thick
9.88
-
-
Providing & fixing glazing in door,window,ventilator shutters & partitions etc.
complete as per the architectural drawings and the directions of engineer-in-charge.Float glass panes of 5.5mm thickness
8.45
-
-
Providing and fixing hydraulic door closer ISI mark with necessary screw etc.complete
I.S.I Designation No. III (size of door 851mm to 1000mm)
6
-
-
Wire gauze imported teakwood door shutter without springs housed in chowkats 35mm thick
13.82
-
-
Wire gauge fixed on chowkats with 25mm thick Imp. Teak Wood wood cover molding of full width.
15.46
-
-
Providing & fixing 6" stainless steel handles ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge.
35
-
-
Providing & fixing 9" stainless steel handles ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge.
20
-
-
Providing & fixing 6" stainless steel tower bolts ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge.
80
-
-
Providing & fixing 8" stainless steel tower bolts ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge.
15
-
-
Providing & fixing commercial plywood 18mm thick
5.57
-
-
Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of
white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete.
129.41
-
-
Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc.
129.41
-
-
Applying priming coat with metal primer on new steel or iron work including
preparation of surface.
31.02
-
-
Painting two or more coats with aluminum paint to give an even shade excluding priming coat
31.02
-
-
Providing and fixing Stainless Steel pipe and fitting of grade A ISI-304 as per IS standard 3448 complete with press type fitting (fitting shall be paid for separately) i/c fixing of the pipe with clamps at 1.00 m spacing including cutting and making good the walls including testing of joints complete as per direction of Engineer-incharge. (The pipe length inserted in the fitting shall not be measured for payment)28.58 mm outer dia Pipe
36.77
-
-
Steel work fixed independently without connecting plates including cutting hoisting and fixing in position TEES ANGLES & CHANNELS
1.8
-
-
Steel work in built up tubular pipes (round, square or rectangular hollow tubes etc. ISI Marked) for flat shed (ie.Where no truss work is involved) including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
2.3
-
-
Corrugated G.I. Sheet roofing 0.80 mm thick fixed with galvanized iron J or L hooks 10mm dia, G.I. Limpot and bitumen washers complete excluding the cost of purling rafters and trusses
18.21
-
-
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement,centring and shuttering in Superstructure
6.36
-
-
Cold twisted deformed(Ribbed/Tor Steel Bar) Bars Fe 500 grade as per IS 1786-2008,for R.C.C works,where not including in the complete rate RCC including bending and placing in position complete
4.99
-
-
Centering and shuttering for flat surfaces such as suspended floors,roofs,landings,chajjas, shelves etc.
48.91
-
-
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing
76.38
-
-
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
64.31
-
-
Top khurra 0.6m×0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16
6
-
-
Dismantling brick work tile, masonry or tile lining in cement
6.36
-
-
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes single socketed (working pressure 4kgf/cm2 ) conforming to IS:4985 including fixing with M.S.clamps
(i) UPVC pipes 110mm dia
40
-
-
Providing and fixing in position gratings 150mm x 150mm for gully trap. PVC grating (P.T.M.T.)
6
-
-
Providing andfixing Chlorinated Polyvinyl Chloride(CPVC) pipes as per IS 15778 (ISI markedwith the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVCplain & brass threaded fittings i/c fixingthe pipe with clamps at 1.00 m spacingincluding jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. (i) CPVC SDR 11 Pipe & fitting 25mm o/d
15
-
-
Providing & Fixing in postion stop cock / Angle valve (as approved by the
Engineer- incharge). (i) C.P.brass 15mm Angle valve
2
-
-
Providing & fixing in position Water Cooler without Stablizer of approved make (to theapproval of Engineer-in-charge ) including carriage complete in all respect.
(i) Water Cooler Semi Steel Body 80/120 ltr Capacity without Stablizer
1
-
-
Providing & fixing in position Commercial RO without reservoir with four no cartridge/ membrane having flow rate 50 ltr/hr with 6 stage purification process of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect
1
-
-
Painting new letters and figures of black synthetic enamel paint to an even shade
1050
-
-
PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
(a) Overall size 1.5sq.mm
200
-
-
(b) Overall size 2.5sq.mm (Un-sheathed)
200
-
-
(c) Overall size 4.00 sq.mm (Un-sheathed)
100
-
-
(d) Overall size 6.00sq.mm (Un-sheathed)
100
-
-
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC
Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends,
junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
(i) Heavy Gauge PVC Conduit Pipe 40mm dia. (Flushed)
150
-
-
Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
((vi)) Wiring 16/20Amp. power plug control point
10
-
-
Supplying and fixing of GI sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of
cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge.
((a)) Door and window frame of size 113mmx60mmx with 35mm wide single rebate
10.06
-
-
((b)) Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter.
47.4
-
-
Bottom khurra on ground 1.2m 0.6m consisting of bricks on edge laid in cement mortar 1:3 over 7.5 cm
6
-
-
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointin (a) UPVC 110 mm bend
12
-
-
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointin
(b) UPVC 110 mm 6.00 88.49 Nos. 530.94 Coupling /Sockets
6
-
-
Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition. ((a)) Size 75 mm x 75 mm
15
-
-
((b)) Size 150 mm x 150 mm
40
-
-
Any other Item
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements