Military Engineer Services Tender

... More
The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Ca No Ce Btz/btd/token/05 Of 2019-20 Provn Of Tech Infrastructure And Otm Accn (sw-177) At Bathinda Mil Stn (ph-ii) in Bathinda, Punjab, with an estimated contract value of Rs. 39,18,00,000. The bid opening date for this tender is 08-07-2019 and the last date for bid submission is 10-08-2019. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Military Engineer Services - MES Tender

Opening Date8 Jul 2019
Closing DateCancelled
Tender Amount₹ 39,18,00,000 
Notes
Download

Costs

Summary

Ca No Ce Btz/btd/token/05 Of 2019-20 Provn Of Tech Infrastructure And Otm Accn (sw-177) At Bathinda Mil Stn (ph-ii)

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
SCHEDULE 'A' SECTION - XIII, (PART-I ) (EXTERNAL WATER SUPPLY WORKS)

-

-

-

... More
Stainless steel nozzle for 15mm bore pipe complete all as specified.

6

-

-

... More
SUBTOTAL

-

-

-

... More
Stainless steel control valve of 15mm bore complete all as specified.

7

-

-

... More
SUB TOTAL

-

-

-

... More
Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 volt to 250 volt with output voltage stabilized 230 Volt with accuracy of +/- 2.5% of capacity 1KVA with mounting bracket complete with time delay relay.(For Water Cooler) complete all as specified .

20

-

-

... More
400 Sq. mm x 3.5 core

900

-

-

... More
SCHEDULE 'A' SECTION - XXIII (DISMANTLING/DEMOLITION WORKS)

-

-

-

... More
Lump sum price worked out by the tenderer for “CHAIN LINK FENCING WORKS” as listed in Schedule ‘A’ Section -IX

1

-

1491709.33

... More
Lump sum price worked out by the tenderer for “(AREA DRAINAGE WORKS” as listed in Schedule ‘A’ Section -XII

1

-

1644369

... More
LED street light fitting, 45 watt with & including LED lamp complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminium alloy, the luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP 65 protection as per IS - 10322-1982 with latest amendments and input voltage range 140 - 300 V, AC, frequency 50-60Hz, PF should be more than 0.9 with Total Harmonic Distoration THD(I) less than 15%,cool white colour and lamp statring time should not be more than 10 second. Fitting should be provided with 10 KV surge protection. Driver should be constant current constant voltage driver. Driver should have high voltage with standing capacity upto 300 V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from (-) 10 degree centrigrade 50 degree centrigrade and humidity level 10 % to 90 % RH. Covers should be polycarbonate/toughened glass to ensure IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM - 79 test report including electric connection complete all as specified. NOTES : (a) The rate quoted is inclusive of 40mm light grade GI tubing 1.5 metre long bent to shape and with necessary clamp to hold the street light fixtures. (b) Pole mounted box to light fitting and service wire cable shall be measured & paid for separately.

105

-

-

... More
Earthing complete with galvanised iron earth plate electrode of size 600x 600x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI strip 32 X 6 mm (upto the body of equipment) by means of GI bolts/nuts/washers, protected by 40 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm bore GI light grade pipe for watering and including funnel, wire mesh,RCC cover & frame, PCC (1:3:6) type C2 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation & earth work, all as specified & shown in electrical plate No. 3 of MES Schedule Part – I. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate.

38

-

-

... More
Construction of valve pit size 750 mm X 750 mm X 750 mm of brick masonry construction including cover of MS sheet 3.15 mm thick and angle iron 40mm x40mmx 6mm with hinges, handle and locking arrangement including painting with two coat of synthetic enamelled paint over a coat of red oxide and grouting to PCC 1:2:4 plastering in cement mortar 1:3, foundation concrete 1:3:6 including necessary earthwork complete all as specified and shown on drawings.

20

-

-

... More
Sub main wiring (with approved colour coding as per IS) with single core FRLS PVC insulated flexible multistranded copper conductor 1.1 KV grade ( main cable : 4 runs of 6 Sq.mm main cable) alongwith two run of single core 6 Sq.mm single core FRLS PVC insulated flexible multistranded copper conductor 1.1 KV grade for earthing drawn through conduit complete all as specified.

120

-

-

... More
Lump sum price worked out by the tenderer for “LIGHTENING PROTECTION WORKS” as listed in Schedule ‘A’ Section -V (Part-I)

1

-

857660

... More
LED Lamp 1 x 5 watt including holder with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks of through holes. The system wattage of fitting should not be more than 5 watt ± 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15 % lumen output should not be less than 351 lumens, total input voltage range 140 - 280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin.

107

-

-

... More
All as per Srl No.7.00 here-in-before but one three pin switch socket outlet 5 Amps on the independant board.

302

-

-

... More
LED light fitting 40 watt wall /surface type including LED tube with driver complete suitable for fixation on roof/wall with body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 40 watt ± 10%, surge protection of minimum 2 kV power factor should be more than 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15 % lumen output should not be less than 90 lumens per watt, total input voltage range 140 - 280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin. MAKE: Havells Cat Part No. STOUTPLUS1200BS40WLED840SPCWH or equivalent in makes mentioned in Appendix 'B' here-in-after.

75

-

-

... More
Water cooler fully stainless steel, electric driven single phase having storage capacity 60 litre and nominal cooling capacity 120 litre per hour mounted on locatiion as directed complete including connecting and making electric connection complete

9

-

-

... More
NOTE FOR POINT WIRING (a) Switch(es) & socket(s) shall be measured & paid for separately under respective item of Schedule 'A'. (b) GI boxes shall be fixed flush to walls in position with cement mortar (1:4) complete all as directed.

-

-

-

... More
SCHEDULE 'A' SECTION-II (PART-II) (INTERNAL ELECTRIFICATION WORKS)

-

-

-

... More
High bay beam energy efficient LED light fitting of 500 watt specifically desighed heat sink for long life vertical high bay / medium LED luminaries including LED lamp complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminium alloy including fixing on wall/roof with help of suitable GI clamps, nuts, bolts and washers etc complete all as directed. The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP 65 protection as per IS - 10322-1982 with latest amendments and input voltage range 140 - 300 V, AC, frequency 50-60Hz,PF should be more than 0.9 with Total Harmonic Distoration THD(I) less than 15%,cool white colour and lamp statring time should not be more than 10 second. Fitting should be provided with 10 KV surge protection. Driver should be constant current constant voltage driver. Driver should have high voltage with standing capacity upto 300 V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from (-) 10 degree centrigrade 50 degree centrigrade and humidity level 10 % to 90 % RH. Covers should be polycarbonate/toughened glass to ensure IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM - 79 test report.

52

-

-

... More
Lump sum price worked out by the tenderer for “RCC HUME PIPE CULVERT WORKS” as listed in Schedule ‘A’ Section -IX

1

-

188728.9

... More
SCHEDULE 'A' SECTION - XIV, (PART-II) (EXTERNAL ELECTRIFICATION WORKS)

-

-

-

... More
Subtotal

-

-

-

... More
MCB suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 40 Amp complete all as specified.

5

-

-

... More
SCHEDULE 'A' SECTION- VI (PART-II) (SEWAGE DISPOSAL WORKS)

-

-

-

... More
Hi wall mounted split type air conditioner 5 star rated and EER 3.2, of capacity 4500K.cal ( 1.5 Ton), electric drivesingle phase 230 Volt 50 hz AC supply indoor & outdoor unit complete with cordless remote & mounted on brackets for outdoor unit including provision of waste water pipe from indoor unit to outside the building complete all as specified .

14

-

-

... More
SCHEDULE 'A' SECTION - XVII (PART-II) (SUMMER APPLIANCES WORKS)

-

-

-

... More
Lump sum price worked out by the tenderer for “EXTERNAL WATER SUPPLY WORKS” as listed in Schedule ‘A’ Section -XIII

1

-

850157.1

... More
Laying of DWC (Double wall corrugated) HDPE pipe 90/76 Sqmm in trenches for cable protection with necessary connecting material i.e. snapfit coupler etc. complete all as specified.

2100

-

-

... More
LT panel board, Outdoor type CPRI Approved all as specified in PSS-II clause 19B.36.2, installing, commissioning & testing comprising the following components/acessories: - (a) Copper bus bar of 400 Amp capacity, 4 strip mounted on porcelain insulators. (b)     MCCB 4 pole, 415 volt, 250 Amps,thermal/magnetic based, 25 kA (Ics=100% of Icu) - 01 No. (Incomming). (c)     MCCB 4 pole, 415 volt, 63 Amps, thermal/magnetic based, 16 kA (Ics=100% of Icu) - 05 Nos. (Outgoing). (d)     MCCB 4 pole, 415 volt, 100 Amps, thermal/magnetic based, 16 kA (Ics=100% of Icu) - 02 Nos. (Outgoing). (e)     MCCB 4 pole, 415 volt, 32 Amps, thermal/magnetic based, 16 kA (Ics=100% of Icu) - 03 Nos. (Outgoing). (f)     MCB DP, 20 Amp, 'C' Curve,10 kA - 02 Nos. (g) Multifunctional meter electronic with suitable CTs, showing Amp, Volt, PF, HZ and oother parameter rating Amp upto 300A and volt upto 500V -01 Set. (h) LED indicating lamp for R,Yand B phases-01set (set of three) (j) Internal power & control wiring with suitable size PVC insulated multistranded copper wire

2

-

-

... More
Lump sum price worked out by the tenderer for “ELECTRIFICATION WORKS” as listed in Schedule ‘A’ Section -XIV (Part-I)

1

-

959988.95

... More
Lump sum price worked out by the tenderer for “SEWAGE DISPOSAL WORKS” as listed in Schedule ‘A’ Section -VI (Part-I)

1

-

1465536.8

... More
Forming Construction Joints 08mm wide and 25mm deep with diamond cutter & provision of 12mm dia polythene backup rod and sealed with pitch free polythylen grey sealent (minimum depth of sealent above backup rod shall be 12mm ) conforming to BS-5212 (type FB) priming the site as recommended by manufacturers instructions and applying masking tape on edge of joint to prevent accidental spillage of sealent and removing the masking tape after the sealent is applied, complete all as specified & as directed.

200

-

-

... More
SUBTOTAL

-

-

-

... More
400 micron HDPE sheet polythene black, conforming to IS -2508 complete all as specified and directed.

1720

-

-

... More
M & L solar road stud (125x125x25mm) made of Aluminium alloy shell water proof accoring to IP65, high efficiency Mono crystalliane Solar panel 1.4V/0.3Watt with one Ni-Mh of Ni-Cd re-chargable battery (1.2V/1600MA) view distance upto 1000 mere complete all as specified and directed. Make: - Model No. Dhruv of Make Dark Eye or equivalent model number of make 3M ( India Ltd)/ Greenlite.

50

-

-

... More
Contd item No 191.00/- (C) Alternator:- Synchronous alternator rated at 250 KVA 415 Volts at 1500 RPM 3 phase 50Hz, AC supply with 0.8 lagging power factor. The alternator shall be having SPDP enclosure, brushless, continuous duty, self excitstion and self regulated through AVR confirming to IS:4722 / BS2613 suitable for tropical conditions and with class F/H insulation. (D) Base frame and foundation:- Both the engine and alternator shall be mounted on common base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration arrangement as per recommendation of manufacturer.

-

-

-

... More
Sub main wiring (with approved colour coding as per IS) with single core FRLS PVC insulated flexible multistranded copper conductor 1.1 KV grade ( main cable : 4 runs of 10 Sq.mm main cable) alongwith two run of single core 10 Sq.mm single core FRLS PVC insulated flexible multistranded copper conductor 1.1 KV grade for earthing drawn through conduit complete all as specified.

350

-

-

... More
LT panel board, Outdoor type CPRI Approved all as specified in PSS-II clause 19B.36.2, installing , commissioning & testing comprising the following components/acessories: - (a) Copper bus bar of 200 Amp capacity, 4 strip mounted on porcelain insulators. (b)     MCCB 4 pole, 415 volt, 63 Amps, thermal/magnetic based, 16 kA (Ics=100% of Icu) - 01 No. (Incomming). (c)     MCCB 4 pole, 32 Amp, 415 volt, 25 kA - 02 Nos. (Outgoing) (d)     MCB 2 pole, 16 Amp, 'C' Curve,10 kA - 14 Nos. (Outgoing) (e) LED indicating lamp for R,Yand B phases-01set (set of three) (f) Internal power & control wiring with suitable size PVC insulated multistranded copper wire.

1

-

-

... More
Addtressable electronic sounder cum strobe all as specified and directed. Make- COOPER/MORLEY

3

-

-

... More
MCCB suitable for 415 volts AC supply, 4 pole with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 40 to 63 Amp complete all as specified.

3

-

-

... More
Thermo plastic road marking painting, 10 cm/5cm wide and 2mm thick (Lines, dashes, arrows, letters etc. on new road surfaces) with road safety spikeries glass beads including preparation of new road surfaces and applying paint by using special applicator machine with heating arrrangement complete all as specified.

561

-

-

... More
Construction of PEB Hanger (75m x 50mX10M) with UH Flt annexe including hanger gates, one side double storeyed and one side single storeyed including flooring 250mm thick PQC having flexural strength 45 kg/Sqcm over 400 micron HDPE sheet with tack coat @ 2.5 kg/Sqm of VG-10 over 100mm DLC over 100mm WMM over 150mm GSB over compacted sub base inlcuding PU epoxy coating, complete all as specified and shown on drawings.

1

-

-

... More
DWCPE pipe 150 mm dia conforing to IS 16098-2013 complete laid on PCC bed 150 mm thick PCC in 1:4:8 type C2 including packing under and haunching against the sides of pipe(s) with concrete pipes after they are laid and tested all as specified and directed.

850

-

-

... More
DWCPE pipe 150 mm dia conforing to IS 16098-2013 complete laid on PCC bed 150 mm thick PCC in 1:4:8 type C2 including packing under and haunching against the sides of pipe(s) with concrete pipes after they are laid and tested all as specified and directed.

300

-

-

... More
SUBTOTAL

-

-

-

... More
Lump sum price worked out by the tenderer for “OPEN PAVED AREA WORKS” as listed in Schedule ‘A’ Section - IV

1

-

56598.67

... More
Wiring with TV coaxial RG-6 heavy duty PVC insulated sheathed cable with copper conductor having single strand of 0.7 mm dia and a copper wire net for TV antenna from terminal boxes to TV socket complete all as specified (conduit pipe and fittings shall be measured and paid separately).

150

-

-

... More
SCHEDULE 'A' SECTION - XVI, (PART-I) (HOT WATER SUPPLY WORKS)

-

-

-

... More
Lump sum price worked out by the tenderer for “INTERNAL WATER SUPPLY WORKS” as listed in Schedule ‘A’ Section - III (Part-I)

1

-

190597

... More
Cast Iron Sluice valve flanged Type, class PN-1, 80 mm bore ISI marked conforming to IS- 14846-2000 complete with stainless steel spindle flanged both ends drilled CI gate with brass ring and iron wheel handle suitable for CI/DI pipe line complete all as specified.

2

-

-

... More
SCHEDULE 'A' SECTION - XIX (AIR COMPRESSOR LINE WORKS)

-

-

-

... More
Flame proof Point wiring with 1.5 Sqmm nominal area PVC insulated unsheathed multistranded copper conductor cable in and including ERW rigid conduit stove enamelled concealed conduit for one light point / Fan point / 5 Amp multipurpose switch socket with other than FP junction box, FP bend, FP reducer independent for 2 light points controlled by one (MCB) including copper wire as specified above for earth wire to common earth and connected to earth dolly complete all as specified. Following articles required for wiring shall be incorporated as required basis and cost there of shall be included in the rate quoted: - (a) Flame proof junction box 3 way suitable for ¾” ERW conduit material LM-6. (b) Flame proof junction box 2 way suitable for ¾” ERW conduit material LM-6. (c) Flame proof junction box 3 way suitable for3/4" ERW conduit material LM-6 (d) Supply and fix flame proof union suitable for 20 mm dia ERW conduit

2

-

-

... More
M&L Point wiring complete with 2.5 sqmm (Nominal area) PVC insulated flame retardant low smoke un-sheathed and multistranded copper conductor cable ISI marked in and including PVC concealed conduit medium quality and conduit fitting for 3 pin 15 Amp multipurpose switch socket combination including PVC insulated 2.5 Sqmm single core copper earth wire to common earth and connected to earth dolly and including suitable MS sunken box of suitable size and covered with & including 3 mm thick bakelite, laminated hylem sheet top cover etc complete all as specified and directed.

217

-

-

... More
MCB suitable for 240 volts AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6 to 32 Amp complete all as specified.

94

-

-

... More
25 Sq. mm x 4 core

710

-

-

... More
Supply, installing, testing and commissioning of silent Diesel Engine driven generating set of capacity 250 KVA, 415 volts, 3 phase 4 wire as per IS: 10001/10002 and alternator as per IS 13364 complete with realy panel for automatic starting on main failure control panel with necessary matters and sound proof canopy and foundation etc complete and including the following:- (A) Diesel Engine :- Diesel Engine 4 stroke water cooled electric start of suitable BHP at 1500 RPM suitable for above output of alternature at 47 degree C, 50% RH and conforming to BS 5514, BS 649 IS 10000 capable if taking 10% over loading for one hour after 12 hour of continous operation. The Engine will be fitted complete with all the required accessories. (B) Engine mounted instrument panel fitted with and having digital for following: (i) Start top switch with key. (ii) Water temperature indication. (iii) Lubrication oil pressure indication. (iv) Battery charging indication. (v) RPM indication. (vi) Over speed indication. (vii) Low lub, oil trip indication. (viii) Engine hour indication.

1

-

-

... More
Lump sum price worked out by the tenderer for “SUMMER APPLIANCES WORKS” as listed in Schedule ‘A’ Section -XVII (Part-I)

1

-

218601.3

... More
Blanking plate of plastic and fixed in location (Suitable for distribution board)

88

-

-

... More
SCHEDULE 'A' SECTION-I (BUILDING/STRUCTURE WORKS)

-

-

-

... More
SCHEDULE 'A' SECTION-II (PART-I) (INTERNAL ELECTRIFICATION WORKS)

-

-

-

... More
SCHEDULE 'A' SECTION - XI (BOUNDRY WALL WORKS)

-

-

-

... More
Ceiling fan of 1200 mm sweep, BEE approved, 5 star rating single phase, AC supply, 240 Volt, including canopies, three number blades, down rod, double ball bearing with capacitor of 2.5 mfd and making connection with and including PVC insulated PVC sheathed copper conductor flexible cable 3 core of suitable size from ceiling rose or connector to fan including marking of MES number complete all as specified. NOTE:The length of suspension rod shall be as per site requirement.

277

-

-

... More
20 mm bore

350

-

-

... More
SCHEDULE 'A' SECTION - XXI (STANDBY DG SET WORKS)

-

-

-

... More
Fire alarm control panel complying with BS EN 54 single loop panel capacity from 99 detectors & 99 modules upto 200 detector and modules complete all as specified. Make- COOPER/MORLEY

3

-

-

... More
Cutting of existing CI pipe line 150 mm bore for taking branch connection inserting flanged type DI Tee 150 x 150 x 80 mm alongwith two tail piece one end flanged and other end socketed complete all as specified .

2

-

-

... More
LED security light fitting, 25 watt with & including LED lamp complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminium alloy including fixing on wall with 1.2 metre long GI pipe 32 mm bore medium grade bracket at 120 degree angle with help of suitable GI clamps, nuts, bolts and washers etc complete all as directed. The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP 65 protection as per IS - 10322-1982 with latest amendments and input voltage range 140 - 300 V, AC, frequency 50-60Hz,PF should be more than 0.9 with Total Harmonic Distoration THD(I) less than 15%,cool white colour and lamp statring time should not be more than 10 second. Fitting should be provided with 10 KV surge protection. Driver should be constant current constant voltage driver. Driver should have high voltage with standing capacity upto 300 V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from (-) 10 degree centrigrade 50 degree centrigrade and humidity level 10 % to 90 % RH. Covers should be polycarbonate/toughened glass to ensure IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM - 79 test report.

165

-

-

... More
SCHEDULE 'A' SECTION - XIII, (PART-II ) (EXTERNAL WATER SUPPLY WORKS)

-

-

-

... More
Laying of DWC (Double wall corrugated) HDPE pipe 63/50 Sqmm in trenches for cable protection with necessary connecting material i.e. snapfit coupler etc. complete all as specified.

9600

-

-

... More
Exhaust fan 300 mm heavy metal body, mounted in suitable opening arrangement with louvers shutters suitable for operation on 240 volt, single phase, 50 cycle per second, AC supply and connecting up including three core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2 mm drawn in flexible PVC conduit from ceiling rose or connector to fan including marking of MES number and fixed in position by using 4 Nos, 200 mm long, 12 mm dia fasteners, nuts, washers and grouted in wall with CM (1:3) complete all as specified .

38

-

-

... More
240 Sq. mm x 3.5 core

375

-

-

... More
LT panel board, Outdoor type all CPRI Approvedas specified in PSS-II clause 19B.36.2, installing , commissioning & testing comprising the following components/acessories: - (a) Copper bus bar of 200 Amp capacity,4 strip mounted on porcelain insulators. (b)     MCCB 4 pole, 415 volt, 100 Amps, thermal/magnetic based, 16 kA (Ics=100% of Icu) - 01 No. (Incomming). (c)     MCCB 4 pole, 415 volt, 63 Amps,thermal/magnetic based, 16 kA (Ics=100% of Icu) - 01 No. (Outgoing). (d)     MCB 4 Pole, 32 Amp, 'C' Curve,10 kA - 01No (Outgoing) (e)     MCB 25 Amp,TPN, 'C' Curve,10 kA - 02 Nos.(Outgoing) (f)     MCB DP, 16 Amp, 'C' Curve,10 kA - 05 Nos.(Outgoing) (g) Auto control time switch, timer control for different 24 hours adjustable type including power contactor of capacity 20 Amps complete- 01 no (g) Multifunctional meter electronic with suitable CTs, showing Amp, Volt, PF, HZ and oother parameter rating Amp upto 300A and volt upto 500V -01 Set. (h) LED indicating lamp for R,Yand B phases-01set (set of three) (j) Internal power & control wiring with suitable size PVC insulated multistranded copper wire.

1

-

-

... More
6 Sq. mm x 2 core

225

-

-

... More
LT panel board, Outdoor type CPRI Approved all as specified in PSS-II clause 19B.36.2, installing , commissioning & testing comprising the following components/acessories: - (a) Copper bus bar of 200 Amp capacity, 4 strip mounted on porcelain insulators. (b)     MCCB 4 pole, 415 volt, 63 Amps, thermal/magnetic based, 25 kA (Ics=100% of Icu) - 01 No. (Incomming). (c)    MCCB 4 pole, 32 Amp,415 volts, 'C' Curve,25 kA - 02 Nos. (Outgoing) (d)     MCB DP, 20 Amp, 'C' Curve,10 kA - 09 Nos. (Outgoing) (e) LED indicating lamp for R,Yand B phases-01set (set of three) (f) Internal power & control wiring with suitable size PVC insulated multistranded copper wire.

1

-

-

... More
LED mirror light fitting 1 x 8/10 watt including LED tube complete suitable for fixation on wall with body robust, corrosion resistant, superior finish and without any cracks of through holes. The system wattage of fitting should not be more than 8/10 watt ± 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15 % lumen output should not be less than 90 lumens per watt, total input voltage range 140 - 280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin.

68

-

-

... More
Thermoplastic (polystreen) junction box having IP65 protection of size 200 x 160 X 98 mm fixed to pole with MS strip nuts bolts, having provision of 3 phase almn bus bar and MCB 6 Amp SPN, complete of Make Hensel Cat No. K9255 or equivalent.

105

-

-

... More
Painting lines, dashes, arrows letter, marking etc. of 3mm thick film on new surface or previously treated road surface with retro-reflective thermoplastic road marking paint (white/golden/yellow) confirming to MORTH (Clause 803.4) all as specified with 8% glass beads using special applicator machine with heating arrangement upto 160 C including cleaning and drying the existing runway surfaces to ensure dust, oil, grease and moisture free surfaces before applying the paint, complete all as specified & as directed by Engineer-in-charge.

250

-

-

... More
SCHEDULE 'A' SECTION-IX (RCC HUME PIPE CULVERT WORKS)

-

-

-

... More
Wiring with twin core PVC insulated sheathed cable with copper conductor having single strand of 0.6 mm dia taped for telephone wiring from terminal box to telephone socket complete all as specified (conduit and conduit accessories shall be measured and paid separately).

600

-

-

... More
MCB suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6 to 32 Amp complete all as specified.

328

-

-

... More
High bay beam LED light fitting of 70 watt specifically desighed heat sink for long life vertical high bay / medium LED luminaries including LED lamp complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminium alloy including fixing on wall/roof with help of suitable GI clamps, nuts, bolts and washers etc complete all as directed. The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP 65 protection as per IS - 10322-1982 with latest amendments and input voltage range 140 - 300 V, AC, frequency 50-60Hz,PF should be more than 0.9 with Total Harmonic Distoration THD(I) less than 15%,cool white colour and lamp statring time should not be more than 10 second. Fitting should be provided with 10 KV surge protection. Driver should be constant current constant voltage driver. Driver should have high voltage with standing capacity upto 300 V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from (-) 10 degree centrigrade 50 degree centrigrade and humidity level 10 % to 90 % RH. Covers should be polycarbonate/toughened glass to ensure IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM - 79 test report. MAKE: Jaquar Cat Part No. LHBL090070XW or equivalent in makes mentioned in Appendix 'B' here-in-after.

18

-

-

... More
Street light bracket made out of 40mm dia GI tubing medium grade made to shape 1.5 Mtr long with fixing arrangement for LED fitting duly painted with synthetic aluminium paint over a coat of primer including MS clamps and back plates fabricated from steel section including nuts, bolts, washer etc complete all as specified.

45

-

-

... More
MCB suitable for 240 volts AC supply, TP with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6 to 32 Amp complete all as specified.

34

-

-

... More
LED high power Cob light fitting of 26 watt specifically desighed heat sink for long life vertical /horizontal surface mounting, LED luminaries including LED lamp complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminium alloy including fixing on wall/roof with help of suitable GI clamps, nuts, bolts and washers etc complete all as directed. The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP 65 protection as per IS - 10322-1982 with latest amendments and input voltage range 140 - 300 V, AC, frequency 50-60Hz,PF should be more than 0.9 with Total Harmonic Distoration THD(I) less than 15%,cool white colour and lamp statring time should not be more than 10 second. Fitting should be provided with 10 KV surge protection. Driver should be constant current constant voltage driver. Driver should have high voltage with standing capacity upto 300 V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from (-) 10 degree centrigrade 50 degree centrigrade and humidity level 10 % to 90 % RH. Covers should be polycarbonate/toughened glass to ensure IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM - 79 test report. MAKE: Havells Cat Part No.ENDURAWELLGLASSNEOTSS26WLED757SPCSO or equivalent in makes mentioned in Appendix 'B' here-in-after.

76

-

-

... More
(e) Push button control unit: For remote control of barrier ,consisting of three push buttons. (f) Cable requirement: (i) 4 core x 1.5 Sqmm unarmoured flexible control cable between push button unit & mechanism box. (ii)3 core unarmoured cable for 230 V 5 amps AC power supply to barrier (with earthing from power point to mechanism) Make:HEIDZ INDIA

-

-

-

... More
Lump sum price worked out by the tenderer for “INTERNAL ELECTRIFICATION WORK” as listed in Schedule ‘A’ Section - II (Part-I)

1

-

342294.6

... More
GI tubing light grade, ISI marked, fixed to wall, poles or laid in trenches for cable protection including fittings complete all as specified of size: -

-

-

-

... More
Sheet metal enclosure including single pole and neutral enclosure with two pin, earth plug and socket complete with one No MCB SP of capacity 20 Amp,10 kA complete all as specified.

21

-

-

... More
16 Sq. mm x 4 core

6136

-

-

... More
Fire alarm point wiring in surface with two 1.50 sqmm PVC insulated. Unsheated, single core multistranded copper conductor FR-LS cable 1100 volts grade including 1.50 sqmm PVC insulated, unsheathed, solid copper conductor FR-LS cable as earth continuity conductor drawn through in and inclusing rigid stove enamelled MS conduit not lees than 20mm dia with its accessories & making good the disturbed surface complete all as specified and directed.

3200

-

-

... More
Delineator 600 mm long made of ABS material round body fitted with two no. of 100mm dia highly reflective refletormade of PMMA material mounted on the rectangular steel pipe 75mmx25mm x600mm long duly powder coated anti dust and fixing in cement concrete 1:2:4 with size of block 300mmx300mmx350mm deep including earth work complete all as specified and directed. Make: - Model No. DA-76ABS of Make Dark Eye or equivalent model number of make 3M ( India Ltd)/ Greenlite.

100

-

-

... More
MCB suitable for 240 volts AC supply, TPN with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6 to 32 Amp complete all as specified.

29

-

-

... More
35 Sq. mm x 3.5 core

2455

-

-

... More
Lump sum price worked out by the tenderer for “BOUNDRY WALL WORKS” as listed in Schedule ‘A’ Section -X

1

-

1224505.55

... More
Sub main wiring (with approved colour coding as per IS) with single core FRLS PVC insulated flexible multistranded copper conductor 1.1 KV grade ( main cable : 2 runs of 4 Sq.mm main cable) alongwith one run of single core 4 Sq.mm single core FRLS PVC insulated flexible multistranded copper conductor 1.1 KV grade for earthing drawn through conduit complete all as specified. NOTE FOR SERIAL ITEM 28.00 TO 30.00: (a) Conduit & conduit acessories shall be measured and paid for separately. (b) For payment purpose, total run of main cable (each run of one running metre) as mentioned above and total run (one running metre) of earth cable shall be considered together as '1 Running Metre)

150

-

-

... More
All as per Srl No.7.00 here-in-before but controlled by two, 2-way switches complete all as specified and directed.

10

-

-

... More
LED light fitting 1 x 20 watt wall /surface type including LED tube with driver complete suitable for fixation on roof/wall with driver complete suitable body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 20 watt ± 10%, surge protection of minimum 2 kV power factor should be more than 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15 % lumen output should not be less than 90 lumens per watt, total input voltage range 140 - 280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin. MAKE: Havells Cat Part No.ENDURALINEARNEOBS20WLED865SPCWH or equivalent in makes mentioned in Appendix 'B' here-in-after.

782

-

-

... More
SCHEDULE 'A' SECTION - VIII (INTERLOCKING PAVER BLOCK WORKS)

-

-

-

... More
16 Sq. mm x 2 core

450

-

-

... More
20 mm bore

150

-

-

... More
Supply, install, commissioning and testing road barrier (electrically operated ) complete with following major components and making complete functional: (a) Drive Mechanism: Consisting of Max 1/4 HP crompton greaves/General electric reversible motor, copupled through a timing belt ("V" belt) to oil filled and sealed type composite gear drive unit internal unit with internal looking feather ,friction clutch, circuit controller ,hand crank arrangement for manual operation at the time of failure, control switch gear with L & T contactors motor rating MCB , electronic surveilance circuit terminals etc, complete as required system should be such to work will in voltage range of 200 to 250 Volt , 50 Hz AC. b) Aluminium Boom: To cover road width of 6 mtr fabricated from 2.5 mm & 1.9 mm aluminium sheet dia pressed to form tapering with riveted joint plates to form a tapering box section, special stiffening bends shall be provided in web of channel to increase the strength, size of boom section at the larger end should be minimum 160 x 160 mm. Total boom shall have 2 to 4 such section of 2.4mtr length each which should be jointed by nuts and bolts for replacement of demage sections. Boom to be painted with alternative black yellow strips and provided with reflective "STOP" sign in centre and four bands of reflective tape for night warning. (c) Counter balance channels and blades: For fixing of boom to the mechanism and for counter balancing the road barrier .These should be of mild steel. (d) Boom Stand: The spotting of tip of the boom in its forward position, this should be in MS with suitable rubber pad.

2

-

-

... More
Road studs (100 x 100 x 18.5 mm) made ABS material with two relector fitted in the body and dinamically designed to bear load upto 25 ton and impact strengtg of about 255 KN wt of stut 130 gms, in red/white/yellow colour with swareflex bead, the material should be non breakable, dustproof including fixing with bitumen adhesive BT69 complete all as specified and directed. Make :- Model No. DA-978(B) of make Dark Eye or equivalent model number in make Make:-3M (India Ltd)/ Greenlite.

500

-

-

... More
Remote response indicators complete all as specified and directed. Make- COOPER/MORLEY.

10

-

-

... More
LT panel board, Outdoor type CPRI Approved all as specified in PSS-II clause 19B.36.2, installing, commissioning & testing comprising the following components/acessories: - (a) Copper bus bar of 200 Amp capacity,4 strip mounted on porcelain insulators. (b)     MCCB 4 pole, 415 volt, 125 Amps, thermal/magnetic based, 16 kA (Ics=100% of Icu) - 01 No. (Incomming). (c)     MCCB 4 pole, 415 volt, 63 Amps,thermal/magnetic based, 16 kA (Ics=100% of Icu) - 01 No. (Outgoing). (d)     MCB 4 Pole, 16 Amp, 'C' Curve,10 kA - 04 Nos.(Outgoing) (e)     MCB DP, 16 Amp, 'C' Curve,10 kA - 04 Nos.(Outgoing) (f) Multifunctional meter electronic with suitable CTs, showing Amp, Volt, PF, HZ and oother parameter rating Amp upto 300A and volt upto 500V -01 Set. (g) LED indicating lamp for R,Yand B phases-01set (set of three) (h) Internal power & control wiring with suitable size PVC insulated multistranded copper wire.

1

-

-

... More
Stainless steel pipe (AISL-304) 20mm bore schedule-10 wall thickness 2.11mm in floor or in trench complete with all fitting accessories i.e. bend, socket, reducer, tee etc. as required at site complete all as specified .

160

-

-

... More
SUBTOTAL

-

-

-

... More
Lump sum price worked out by the tenderer for “SITE CLEARANCE & EARTH WORKS” as listed in Schedule ‘A’ Section -XXII

1

-

15736016.7

... More
SCHEDULE 'A' SECTION-IA (PEB HANGER WORKS)

-

-

-

... More
SCHEDULE 'A' SECTION-VII, (PART-I) (BITUMINOUS ROAD WORKS)

-

-

-

... More
LT XLPE insulated cable screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor conforming to IS-7098 (Part-I -1988) laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing complete all as specified of sectional area: -

-

-

-

... More
SCHEDULE 'A' SECTION - XV, (PART-II) (LIGHTENING PROTECTION WORKS)

-

-

-

... More
LED DECORATIVE light fitting surface mounted 1x34 watt 2x2 LED plat panel with driver complete suitable for fixation on roof/false ceiling with body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 34 watt ± 10%, surge protection of minimum 2 kV power factor should be more than 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15 % lumen output should not be less than 90 lumens per watt, total input voltage range 140 - 280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin. MAKE: Havells Cat Part No. PLUTOSURFACE2X2PLS34WLED840S or equivalent in makes mentioned in Appendix 'B' here-in-after.

51

-

-

... More
M&L for Point wiring complete with 1.5 sqmm (Nominal cross sectional area) PVC insulated flame retardant low smoke un-sheathed and multistranded copper conductor cable with colour code ISI marked and including PVC concealed conduit ISI marked and conduit fittings for one light point/fan point /engagement light controlled by one switch including PVC insulated 1.5 Sqmm single core copper earth wire to common earth and connecting to earth dolly and including suitable MS sunken box of suitable size and covered with & including 3 mm thick bakelite laminated sheet (ISI marked) top cover etc complete all as specified and directed. (Cost of MS sunken box and bakelite sheet included in the rate)

1737

-

-

... More
Lump sum price worked out by the tenderer for “HOT WATER SUPPLY WORKS” as listed in Schedule ‘A’ Section -XVI (Part-I)

1

-

75345.2

... More
SCHEDULE 'A' SECTION - XXII (SITE CLEARANCE & EARTH WORKS)

-

-

-

... More
LED flood light fitting of 150 Watt including LED lamp complete with body robust, corrosion resistant, superior finish and without any cracks or through holes,made in a single piece by high pressure die cast aluminium alloy.The luminaries shall be monolithic construction totally enclosed, dust and water proof with minimum IP -65 protection with COB LED as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 300 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distoration THD(I) less than 15% ,cool white colour and lamp starting time should not be more than 10 second. Fitting should be provided with 10 KV surge protection.Driver should be constant current constant voltage driver .Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection,no load , open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from -10 degree Centrigrade to 50 degree Centrigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 66 degree protection. Cover should not degrade due to heating and ageing.The efficiency of LED luminaries system shall be more than 90 lumens per watt and must be certified by the LM-79 test report including electric connection complete all as specified.

20

-

-

... More
SCHEDULE 'A' SECTION-III, (PART-I) INTERNAL WATER SUPPLY WORKS

-

-

-

... More
Frost free single door refrigerator electric driven single phase 230 volts, AC 50 Hz,of capacity 195 litre with BEE approved, 5 star rating with inbuilt stablizer complete including electric connection through buck/ boost transformer complete all as specified .

7

-

-

... More
SCHEDULE 'A' SECTION- V (PART-II) (DISPERSAL AND TAXI TRACK WORKS)

-

-

-

... More
LED flame proof tube light fitting 1x 20 watt including LED tube with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks or through holes with minimum IP-65 protection. The system wattage of fitting should not be more than 20 watt ± 10%, surge protetion of minimum 2KV power factor should be more than 0.90, cool while colour, total hormonic distoration (THD) should not be more than 15%, total input voltage range 140-280V AC, colour rendering Index should not be less than 80, Corelated colour should be minimum 6000 degree Kelvin suitable for Gas/vapur of IIA & IIB and Zone 1& 2 including connecting up with twin core twisted flexible copper conductor with suitable size complete all as per specified .

2

-

-

... More
SCHEDULE 'A' SECTION- VI (PART-I ) (SEWAGE DISPOSAL WORKS)

-

-

-

... More
LT panel board, Outdoor type CPRI Approved all as specified in PSS-II clause 19B.36.2, installing, commissioning & testing comprising the following components/acessories: - (a) Copper bus bar of 200 Amp capacity,4 strip mounted on porcelain insulators. (b)     MCCB 4 pole, 415 volt, 63 Amps, thermal/magnetic based, 16 kA (Ics=100% of Icu) - 01 No. (Incomming). (c)    MCB TP, 63 Amp, 415 volts, 'C' Curve,10 kA - 01No (Outgoing) (d)    MCB TP, 32 Amp, 'C' Curve,10 kA - 02 Nos. (Outgoing) (d)    MCB DP, 16 Amp, 'C' Curve,10 kA - 02 Nos. (Outgoing) (e)    Multifunctional meter electronic with suitable CTs, showing Amp, Volt, PF, HZ and oother parameter rating Amp upto 300A and volt upto 500V -01 Set. (f) LED indicating lamp for R,Yand B phases-01set (set of three) (g) Internal power & control wiring with suitable size PVC insulated multistranded copper wire.

4

-

-

... More
Subtotal

-

-

-

... More
Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 volt to 250 volt with output voltage stabilized 230 Volt with accuracy of +/- 2.5% of capacity 5KVA with mounting bracket complete with time delay relay. complete all as specified .

18

-

-

... More
Rigid non metallic, PVC concealed conduit, ISI marked, inclusive of all fitings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing acessories such as couplers, lock nuts, saddles, pipe hook etc. for sub main, TV & telephone wiring and the like complete all as specified of size: -

-

-

-

... More
Angle valve, cast copper alloy, chromium plated, high pressure with quarter turn handle screwed ends for iron pipe or for unions and fixed suitable for 15 mm nominal bore iron pipe complete all as specified.

75

-

-

... More
SUBTOTAL

-

-

-

... More
32 mm bore

450

-

-

... More
SCHEDULE 'A' SECTION- IV (OPEN PAVED AREA WORKS)

-

-

-

... More
Metal top deep freezer single phase 240v, 50Hz of 230 ltrs capacity BEE approved, 5 star rating including necessary electric connection complete all as specified and directed.

1

-

-

... More
LT panel board, Outdoor type all as specified in PSS-II clause 19B.36.2, installing, commissioning & testing comprising the following components/acessories: - (a) Copper bus bar of 600 Amp capacity,4 strip mounted on porcelain insulators. (b)     MCCB 4 pole, 415 volt, 350 Amps, thermal/magnetic based, 25 kA (Ics=100% of Icu) - 01 No. (Incomming). (c)     MCCB 4 pole, 415 volt, 250 Amps, thermal/magnetic based, 16 kA (Ics=100% of Icu) - 02 Nos. (Outgoing). (d) Multi functional digital voltmeter and ampere meter including suitable and appropriate CTs-01 Set. (e) LED indicating lamp for R,Yand B phases-01set (set of three) (f) Internal power & control wiring with suitable size PVC insulated multistranded copper wire (g) On load change over switch 415 volt, 4 pole of capacity 400 Amps including necessary connection - 02Nos

1

-

-

... More
Subtotal

-

-

-

... More
GI box flush mounted 100mm x100mmx100mm having holes for 20 mm conduit entry including 2 pin TV socket outlet flush type duly marked with symbol of TV and 3 mm thick plastic laminated sheet cover complete for TV connection all as specified.

13

-

-

... More
Air circulator heavy duty wall mounting 450 mm sweep, 240 volts, single phase ISI marked with built in selector switch including making connection by using PVC seathed twin core copper cable from ceiling rose to air circulator complete all as specified . NOTE- The air circulator is to be fixed on wall with all necessary T&P and other accessories required shall be deemed to be included in the above item no extra payment will be admissiable on this account.

31

-

-

... More
SCHEDULE 'A' SECTION-III, (PART-II) INTERNAL WATER SUPPLY WORKS

-

-

-

... More
Supply only polyster non circular/triangular synthetic fibre 12 mm long with circum circle diameter 30.35 micron, design for melting point of 240-260 degree C and having specific gravity of 1.34 to 1.40 complete all as specified and directed.

3440

-

-

... More
LT panel board, Outdoor type all as specified in PSS-II clause 19B.36.2, installing , commissioning & testing comprising the following components/acessories: - (a) Copper bus bar of 100 Amp capacity, 4 strip mounted on porcelain insulators. (b)     MCCB 4 pole, 415 volt, 63 Amps, thermal/magnetic based, 16 kA (Ics=100% of Icu) - 01 No. (Incomming). (c)     MCCB 4 pole, 415 volt, 40 Amps, thermal/magnetic based, 16 kA (Ics=100% of Icu) - 01 No. (Outgoing). (d)     MCB DP, 16 Amp, 'C' Curve,10 kA - 05 Nos.(Outgoing) (e) Multifunctional meter electronic with suitable CTs, showing Amp, Volt, PF, HZ and oother parameter rating Amp upto 300A and volt upto 500V -01 Set. (f) LED indicating lamp for R,Yand B phases-01set (set of three) (g) Internal power & control wiring with suitable size PVC insulated multistranded copper wire

1

-

-

... More
Lump sum price worked out by the tenderer for “INTERLOCKING PAVER BLOCK WORKS” as listed in Schedule ‘A’ Section -VIII

1

-

3983071.03

... More
All as per Srl No.7.00 here-in-before but one call bell controlled by one bell switch complete all as specified and directed.

20

-

-

... More
Hi wall mounted split type air conditioner 5 star rated and EER 3.2, of capacity 4500K.cal ( 2 Ton), electric drive single phase 230 Volt 50 hz AC supply indoor & outdoor unit complete with cordless remote & mounted on brackets for outdoor unit including provision of waste water pipe from indoor unit to outside the building complete all as specified .

4

-

-

... More
LT panel board, Outdoor type CPRI Approved all as specified in PSS-II clause 19B.36.2, installing , commissioning & testing comprising the following components/acessories: - (a) Copper bus bar of 100 Amp capacity,4 strip mounted on porcelain insulators. (b)     MCCB 4 pole, 415 volt, 63 Amps, thermal/magnetic based, 16 kA (Ics=100% of Icu) - 01 No. (Incomming). (c)     MCCB 4 pole, 415 volt, 40 Amps, thermal/magnetic based, 10 kA (Ics=100% of Icu) - 01 No. (Outgoing). (d)     MCB TPN, 25 Amp, 'C' Curve,10 kA - 04 Nos. (Outgoing) (e) Auto control time switch, timer control for different 24 hours adjustable type including power contactor of capacity 20 Amps complete- 01 no (f) LED indicating lamp for R,Yand B phases-01set (set of three) (g) Internal power & control wiring with suitable size PVC insulated multistranded copper wire

1

-

-

... More
LT panel board, Outdoor type CPRI Approved all as specified in PSS-II clause 19B.36.2, installing , commissioning & testing comprising the following components/acessories: - (a) Copper bus bar of 200 Amp capacity,4 strip mounted on porcelain insulators. (b)     MCCB 4 pole, 415 volt, 125 Amps, thermal/magnetic based, 16 kA (Ics=100% of Icu) - 01 No. (Incomming). (c)     MCCB 4 pole, 415 volt, 100 Amps,thermal/magnetic based, 16 kA (Ics=100% of Icu) - 01 No. (Outgoing). (d)     MCB 4 pole, 25 Amp, 'C' Curve,10 kA - 02 Nos. (Outgoing) (e)     MCB DP, 16 Amp, 'C' Curve,10 kA - 04 Nos. (Outgoing) (f) Multifunctional meter electronic with suitable CTs, showing Amp, Volt, PF, HZ and oother parameter rating Amp upto 300A and volt upto 500V -01 Set. (g) LED indicating lamp for R,Yand B phases-01set (set of three) (h) Internal power & control wiring with suitable size PVC insulated multistranded copper wire.

1

-

-

... More
LED decorative bulk head light fitting 1 x 10 watt including LED tube complete suitable for fixation on wall with body robust, corrosion resistant, superior finish and without any cracks of through holes. The system wattage of fitting should not be more than 10 watt ± 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15 % lumen output should not be less than 90 lumens per watt, total input voltage range 140 - 280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin. MAKE: Havells Cat Part No.RUGBYNEOFT10WLED860SSYMTOPC or equivalent in makes mentioned in Appendix 'B' here-in-after.

10

-

-

... More
40 mm bore

120

-

-

... More
Lump sum price worked out by the tenderer for “DISMANTLING/DEMOLITION WORKS” as listed in Schedule ‘A’ Section -XXIII

1

-

66100

... More
SCHEDULE 'A' SECTION - XVII, (PART-I) SUMMER APPLIANCES WORKS

-

-

-

... More
SUBTOTAL

-

-

-

... More
SCHEDULE 'A' SECTION - XX (SPECIAL ITEMS FOR WORKS)

-

-

-

... More
Lump sum price worked out by the tenderer for “BITUMINOUS ROAD WORKS” as listed in Schedule ‘A’ Section -VII (Part-I)

1

-

10777777.5

... More
Glass top deep freezer single phase 240v, 50Hz of 320 ltrs capacity BEE approved, 5 star rating including necessary electric connection complete all as specified and directed.

2

-

-

... More
SUBTOTAL

-

-

-

... More
SCHEDULE 'A' SECTION- V (PART-I) (DISPERSAL AND TAXI TRACK WORKS)

-

-

-

... More
LT feeder pillar, Outdoor type CPRI Approved all as specified in PSS-II clause 19B.36.2, installing , commissioning & testing comprising the following components/acessories: - (a) Copper bus bar of 100 Amp capacity, 4 strip mounted on porcelain insulators. (b)     MCCB 4 pole, 415 volt, 63 Amps, thermal/magnetic based, 16 kA (Ics=100% of Icu) - 01 No. (Incomming). (c)     MCB TPN, 25 Amp, 415 volt, 10 kA - 02 Nos. (Outgoing) (d)     MCB 2 pole, 32 Amp, 'C' Curve,10 kA - 4 Nos. (Outgoing) (e) LED indicating lamp for R,Yand B phases-01set (set of three) (f) Internal power & control wiring with suitable size PVC insulated multistranded copper wire.

1

-

-

... More
10 Sq. mm x 2 core

1265

-

-

... More
SCHEDULE 'A' SECTION - XVIII (AIR CONDITIONING WORKS)

-

-

-

... More
95 Sq. mm x 3.5 core

480

-

-

... More
Forming 200mm deep and 25mm thick expansion joints filled with bituminous joint filler board & provision of 25mm dia polythene backup rod and sealed with pitch free polythylen grey sealent (minimum depth of sealent above backup rod shall be 12mm ) conforming to BS-5212 (type FB) priming the site as recommended by manufacturers instructions and applying masking tape on edge of joint to prevent accidental spillage of sealent and removing the masking tape after the sealent is applied, complete all as specified & as directed.

100

-

-

... More
SCHEDULE 'A' SECTION - X (CHAIN LINK FENCING WORKS)

-

-

-

... More
Supply, installation, testing and commissioning, BEE approved, 5 star rated, water heater storage type electric driven single phase 240 volts AC 50 Hz of capacity 25 ltrs complete with vent pipe, flusible plug safety valve, NRV etc., including necessary nut, bolts, inlet and outlet connection pipeof suitable lenghth with anchor bolt of steel brass quoted, not less than 12mm x100mm for cold water inlet and nesessary electrical connection, fixing where directed withcomplete fitting and accessories complete all as specified and directed.

8

-

-

... More
Frost free single door refrigerator electric driven single phase 230 volts, AC 50 Hz,of capacity 350 litre with BEE approved, 5 star rating with inbuilt stablizer complete including electric connection through buck/ boost transformer complete all as specified.

1

-

-

... More
Subtotal

-

-

-

... More
MCCB suitable for 415 volts AC supply, 4 pole with over load and short circuit protection and rupturing capacity not less than 16 kA, 'C' curve type of rating 100 Amp complete all as specified.

1

-

-

... More
Earthing complete with copper earth plate electrode of size 600x 600x 3.15 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including copper strip 25 X 3 mm (upto the body of equipment) by means of GI bolts/nuts/washers, protected by 40 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm bore GI light grade pipe for watering and including funnel, wire mesh,RCC cover & frame, PCC (1:3:6) type C2 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation & earth work, all as specified & shown in electrical plate No. 3 of MES Schedule Part – I. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate.

8

-

-

... More
10 Sq. mm x 4 core

795

-

-

... More
SUB TOTAL

-

-

-

... More
SCHEDULE 'A' SECTION - XIV, (PART-I) (EXTERNAL ELECTRIFICATION WORKS)

-

-

-

... More
70 Sq. mm x 3.5 core

875

-

-

... More
PVC insulated FR cable of size 2.5 Sq.mm, single core, 1100 volt graded, unsheathed stranded copper connections to streel light fittings complete.

750

-

-

... More
Forming Contraction/dummy Joints 08mm wide and 85mm deep with diamond cutter & provision of 12mm dia polythene backup rod and sealed with pitch free polythylen grey sealent (minimum depth of sealent above backup rod shall be 12mm ) conforming to BS-5212 (type FB) priming the site as recommended by manufacturers instructions and applying masking tape on edge of joint to prevent accidental spillage of sealent and removing the masking tape after the sealent is applied, complete all as specified & as directed by Engineer-in-charge.

500

-

-

... More
SCHEDULE 'A' SECTION - XII (AREA DRAINAGE WORKS)

-

-

-

... More
Construction of valve pit size 900 mm X 900 mm X 900 mm of brick masonry construction including cover of MS sheet 3.15 mm thick and angle iron 40mm x40mmx 6mm with hinges, handle and locking arrangement including painting with two coat of synthetic enamelled paint over a coat of red oxide and grouting to PCC 1:2:4 plastering in cement mortar 1:3, foundation concrete 1:3:6 including necessary earthwork complete all as specified and shown on drawings.

2

-

-

... More
SCHEDULE 'A' SECTION - XV, (PART-I) (LIGHTENING PROTECTION WORKS)

-

-

-

... More
Lump sum price worked out by the tenderer for “Building Work / Structure Work” as listed in Schedule ‘A’ Section - I.

1

-

132336820

... More
GI box flush mounted 100mm x100mmx100mm having holes for 20 mm conduit entry including 3 pin telephone socket outlet flush type duly marked with symbol of telephone and 3 mm thick plastic laminated sheet cover complete for telephone connection all as specified.

47

-

-

... More
High bay beam LED light fitting of 250 watt specifically desighed heat sink for long life vertical high bay / medium LED luminaries including LED lamp complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminium alloy including fixing on wall/roof with help of suitable GI clamps, nuts, bolts and washers etc complete all as directed. The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP 65 protection as per IS - 10322-1982 with latest amendments and input voltage range 140 - 300 V, AC, frequency 50-60Hz,PF should be more than 0.9 with Total Harmonic Distoration THD(I) less than 15%,cool white colour and lamp statring time should not be more than 10 second. Fitting should be provided with 10 KV surge protection. Driver should be constant current constant voltage driver. Driver should have high voltage with standing capacity upto 300 V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from (-) 10 degree centrigrade 50 degree centrigrade and humidity level 10 % to 90 % RH. Covers should be polycarbonate/toughened glass to ensure IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM - 79 test report. MAKE: Jaquar Cat Part No. LHBL090070XW or equivalent in makes mentioned in Appendix 'B' here-in-after.

52

-

-

... More
Lump sum price worked out by the tenderer for “DISPERSAL AND TAXI TRACK WORKS” as listed in Schedule ‘A’ Section -V (Part-I)

1

-

23656356.2

... More
80 mm bore

24

-

-

... More
Detectors complying with and type certified to EN- 45 but addressable type multisensor detector with heat and smoke combination photoelectric optical with base with self built intellligence as per IS: 11360 complete all as specified .

270

-

-

... More
Addressable manual call point resettable type complete all specified and directed. Make- COOPER/MORLEY

3

-

-

... More
Frost free single door refrigerator electric driven single phase 230 volts, AC 50 Hz,of capacity 310 litre with BEE approved, 5 star rating with inbuilt stablizer complete including electric connection through buck/ boost transformer complete all as specified .

2

-

-

... More
Water cooler fully stainless steel, electric driven single phase having storage capacity 40 litre and nominal cooling capacity 80 litre per hour mounted on locatiion as directed complete including connecting and making electric connection complete.

8

-

-

... More
Aviation light fitting yellow painted die-cast aluminium alloy housing, red coloured polycarbonate dome and accessories complete with spirial lamp 02 nos of 100W to be fixed on the top of hangers with suitable fixing accessories such as nut bolts, clamp etc. complete all as directed.

2

-

-

... More
SUBTOTAL

-

-

-

... More
Supply, installation, testing and commissioning of solar hot water system of capacity 200 ltrs per day including flat plate collector and other required accessories insulated stainless steel storage tank to be placed on building roof at a suitable height with aluminium cladding angle iron structure cold water tank with inter connection between tank and solar panel and necessary structure and finishing work, foundation including electric back up of 3 KW and electric panel with MCBs and other safety devices such as thermostat relays etc complete all as specified. Note : Cold water piping, hot water piping, cold water tank, electric wiring up to solar panel, MCB and DB shall be measured and paid separately under respective items of Sch 'A'.

2

-

-

... More
Water cooler fully stainless steel, electric driven single phase having storage capacity 40 litre and nominal cooling capacity 40 litre per hour mounted on locatiion as directed complete including connecting and making electric connection complete.

4

-

-

... More
LT panel board, In-door type CPRI Approved all as specified in PSS-II clause 19B.36.2, installing , commissioning & testing comprising the following components/acessories: - (a) Copper bus bar of 200 Amp TPN, three phase 4 wire in separate chamber capacity, 4 strip mounted on porcelain insulators. (b)     MCCB 4 pole, 100 Amp, 'C' Curve, 415 Volt, 25kA - 01 No. (c)     MCB 3 pole, 63 Amp, 3 phase 415 volt, 6 pin industrial socket - 02 Nos. (d)     MCB 3 pole, 32 Amp, 3 phase 415 volt, 5 pin industrial socket - 02 Nos. (e) MCB 3 pole, 32 Amp, 1 phase 230 volt, 5 pin industrial socket - 02 Nos. (f) MCB 2 pole, 16 Amp, 1 phase 230 volt, 3 pin industrial socket - 02 Nos. (g) MCB 2 pole, 20 Amp, 1 phase 230 volt, 3 pin industrial socket - 01 Nos. (h)     Multifunctional meter electronic with suitable CTs, showing Amp, Volt, PF, HZ and oother parameter rating Amp upto 300A and volt upto 500V -01 Set. (j) LED indicating lamp for R,Yand B phases-01set (set of three) (k) Internal power & control wiring with suitable size PVC insulated multistranded copper wire.

4

-

-

... More
Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 volt to 250 volt with output voltage stabilized 230 Volt with accuracy of +/- 2.5% of capacity 2KVA with mounting bracket complete with time delay relay.(For Water Cooler) complete all as specified .

14

-

-

... More
Supply, installation, commissioning of Eveporated air cooler in steel body (desert cooler) with propeller cooler fan made out of hot deep galvanised steel sheet with grade 350 conforming to IS 277-1992, thickness 0.8mm body and 1mm for sump tank with internal surfaces painted with water resistant paint, single phase 230 volts of fan size 450mm sweep (Maximum power consumption 250 volts) ISI marked 5 star rating BEE approved having normal air flow capacity 4000 cum/Hr, leakproof joint , three speed fan regulator, submersible pump of suitable size, piano type switch, indicator lamp etc., overall size of body 44" x 26" x26" and tank size 26" x 26" x10" complete all as specified and directed. (Note (a) :- Sufficient length of 3 core PVC sheathed round copper cable size 23/0.0076mm to enable fixing in to plug point shall be provided by contractor. (b) :- Arrangement of power connections and water connections to the desert cooler will be included in installation.

60

-

-

... More
SCHEDULE 'A' SECTION - XVI, (PART-II) (HOT WATER SUPPLY WORKS)

-

-

-

... More
LT feeder pillar, Outdoor type CPRI Approved all as specified in PSS-II clause 19B.36.2, installing , commissioning & testing comprising the following components/acessories: - (a) Copper bus bar of 100 Amp capacity, 4 strip mounted on porcelain insulators. (b)     MCCB 4 pole, 415 volt, 40 Amps, thermal/magnetic based, 16 kA (Ics=100% of Icu) - 01 No. (Incomming). (c)     MCB TPN, 16 Amp, 415 volt, 10 kA - 04 Nos. (Outgoing) (d)     MCB 2 pole, 32 Amp, 'C' Curve,10 kA - 2Nos. (Outgoing) (e) Auto control time switch, timer control for different 24 hours adjustable type including power contactor of capacity 20 Amps complete- 01 no (e) LED indicating lamp for R,Yand B phases-01set (set of three) (f) Internal power & control wiring with suitable size PVC insulated multistranded copper wire.

1

-

-

... More
Exhaust fan 200 mm sweep pastic body, mounted in suitable opening arrangement with louvers shutters suitable for operation on 240 volt, single phase, 50 cycle per second, AC supply and connecting up including three core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2 mm drawn in flexible PVC conduit from ceiling rose or connector to fan including marking of MES number and fixed in position by using 4 Nos, 200 mm long, 12 mm dia fasteners, nuts, washers and grouted in wall with CM (1:3) complete all as specified .

30

-

-

... More
SCHEDULE 'A' SECTION-VII, (PART-II) (BITUMINOUS ROAD WORKS)

-

-

-

... More
All as per Srl No.7.00 here-in-before but one three pin socket outlet 5 Amps on the same board.

75

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Related Tenders

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.