Military Engineer Services Tender

... More
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date31 Aug 2024
Closing Date26 Sep 2024
Tender Amount₹ 17,46,379 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Summary

Repair/maint Of Incoming/outgoing Vcb,ht Panel And Connected Items At 66 Kv Mrs And Other Ht Sub Stn Under Ge (east) Ferozepur Cantt

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply & fixing in replacement shunt trip coil assy 110 Volt DC (OG838) suitable for 630 Amps VMX type VCB trolly ,11 KV, complete all as specified and as directed by Engineer In Charge.

5

-

-

... More
Supply & fixing in replacement Closing trip coil assy 110 Volt DC (CN-1179) suitable for 630 Amps VMX type VCB trolly 11 KV,  complete all as specified and as directed by Engineer In Charge.                                                    

5

-

-

... More
Supply & fixing in replacement power pack to convert  220 volts AC to 110 Volts DC, along with the switch gear board to cater DC auxiliary supply, complete all as specified and as directed by Engineer In Charge.                                                                                                                                            

3

-

-

... More
Supply & fixing in replacement power convertor input 110-120 volts AC or 200-220 volts AC to output 24 volts DC 2.10 Amp along with switch gear board to cater DC auxiliary supply, complete all as specified and as directed by Engineer In Charge.                                                                                                                                             

2

-

-

... More
Taking out of Differential relay and repairing the same with the replacing of minor spares and made functional refixinging the same control panel of 66 KV transformer No-2. complete all as specified and as directed by Engineer In Charge.                                                                  

1

-

-

... More
Supply & fixing in replacement digital Amp meter of size 96mm x 96mm suitable for 630 Amps VMX  type VCB trolly, 11 KV,  complete all as specified and as directed by Engineer In Charge.                                                                                                         

2

-

-

... More
Supply & fixing in replacement digital volt meter of size 96mm x 96mm suitable for 630 Amps VMX  type VCB trolly, 11 KV,  complete all as specified and as directed by Engineer In Charge.                                                                                          

2

-

-

... More
Supply & fixing in replacement Current transformer  (Apoxy) suitable for HT 11 KV  Incoming feeder  400/200/5 Amps, single phase double core CT of accuracy class. 1.0 and 15 VA, for metering and 15 VA,CL 5P 10 for protection with STR (short time rating ) of 18.4 KA for 1 sec, complete all as specified and as directed by Engineer In Charge. 

2

-

-

... More
All as per item No 11 above here-in-before but for outgoing feeder of cap 200/100/5 Amps, complete all as specified and as directed by Engineer In Charge.

2

-

-

... More
All as per item No 11 above hereinbefore but for outgoing feeder of cap 300/150/5 Amps, complete all as specified and as directed by Engineer In Charge.

2

-

-

... More
All as per item No 11 above hereinbefore but for outgoing feeder of cap 150/75/5 Amps, complete all as specified and as directed by Engineer In Charge.

2

-

-

... More
All as per item No 11 above hereinbefore but for outgoing feeder of cap 100/50/5 Amps complete all as specified and as directed by Engineer In Charge.

2

-

-

... More
Supply & fixing in replacement 11 KV Single phase PT 11 KV/3-110 Volts class1.0 conforming to IS-3156/1992  complete all as specified and as directed by Engineer-Charge.

2

-

-

... More
Supply & fixing in replacement of TNC switch, complete all as specified and as directed by Engineer In Charge.                                                                                                                          

5

-

-

... More
Supply & fixing in replacement HT 11 KV shunt capacitor of capacity 275 KVAR outdoor type single phase fixinging on existing structure including connection with aluminium bus bar & testing complete all as specified and as directed by Engineer In Charge.

1

-

-

... More
Supply & fixing in replacement Moving/fixied contacts suitable for 630 Amps VMX type VCB trolly, 11 KV, complete all as specified and as directed by Engineer In Charge.          

10

-

-

... More
Supply & fixing in replacement vaccum interrupter suitable for 630 amps to 1250 Amps VMX type VCB trolly,11 KV, complete all as specified and as directed by Engineer In Charge.                                                                                                             

1

-

-

... More
Supply & fixing in replacement drive insulator assembly with M 10 nylon nut & spl washer of VCB compartment suitable for 630/1250 Amps VMX/UNIVAC type VCB trolly, 11 KV, complete all as specified and as directed by Engineer In Charge. .

3

-

-

... More
Supply & fixing in replacement of insulator bush of VCB compartment suitable for 630/1250 Amps VMX/UNIVAC  type VCB trolly,11 KV. complete all as specified and as directed by Engineer In Charge.

4

-

-

... More
Supply & fixing in replacement socket contact of VCB compartment suitable for 630/1250 Amps VMX/UNIVAC type type VCB trolly, 11 KV, complete all as specified and as directed by Engineer In Charge.                                                                                                                   

3

-

-

... More
Supply & fixing in replacement bus bar spouts of VCB compartment suitable for 630/1250 Amps VMX/UNIVAC type type VCB trolly, 11 KV, complete all as specified and as directed by Engineer In Charge.

3

-

-

... More
Supply & fixing in replacement contact arm upper suitable for 1250 Amps VMX  type VCB trolly, 11 KV, complete all as specified and as directed by Engineer In Charge. 

1

-

-

... More
Supply & fixing in replacement contact arm lower suitable for 630/800 Amps VMX  type VCB trolly, 11 KV, complete all as specified and as directed by Engineer In Charge. 

1

-

-

... More
Supply & fixing in replacement jaw contact made out of copper for  bushing rod  suitable for 1250/630 Amps VMX type VCB trolly,11 KV, complete all as specified and as directed by Engineer In Charge. 

6

-

-

... More
Material and Labour for servicing and checking of  Incoming/Outgoing VCB trollys of any make, any size, any type, 11 KV, for smooth and proper functioning including checking of all fixinged and moving  parts, cleaning with thinner and air blower painting the internal parts after grinding/buffing to make rust free and checking of all wiring including new wiring where ever required and replacment of minor items like nut bolt , washer, locks, springs, on-off switch,Toggle switch,Indicator lamp/Holder etc of any make/or size complete for 66KV MRS, complete all as specified and as directed by Engineer In Charge.

25

-

-

... More
Material and Labour for calibration and relay setting and checking of  Incoming/Outgoing VCB trollys of any make, any size, any type, 11 KV, for smooth and proper functioning including checking of all wiring including new wiring where ever required complete for 66KV MRS, Power House No-1 and 550 Acre, complete all as specified and as directed by Engineer In Charge.

20

-

-

... More
Supply & fixing in replacement of space heater 240 Volt single phase, complete all as specified and as directed by Engineer In Charge.                                                                                                                                                                  

3

-

-

... More
Supply & fixing in replacement of thermostat 240 Volt single phase range settting from 0 to 90 degree centigrade, complete all as specified and as directed by Engineer In Charge.  

4

-

-

... More
Supply & fixing in replacement  CT bushing  suitable for 630 Amps VMX  type VCB trolly, 11 KV, complete all as specified and as directed by Engineer In Charge. 

1

-

-

... More
Supply & fixing in replacement upper bushing L1 CU  suitable for 1250 Amps VMX  type VCB trolly, 11 KV, complete all as specified and as directed by Engineer In Charge.

1

-

-

... More
Supply & fixing in replacement  upper bushing L3 CU suitable for 1250 Amps VMX  type VCB trolly 11 KV, complete all as complete all as specified and as directed by Engineer In Charge.

1

-

-

... More
Supply & fixing in replacement bushing lower CU suitable for 1250 Amps VMX  type VCB trolly, 11 KV, complete all as specified and as directed by Engineer In Charge.

1

-

-

... More
Supply & fixing in replacement anti pumping contactor, 2NO+2NC suitable for 630 Amps VMX  type VCB trolly, 11 KV, complete all as specified and as directed by Engineer In Charge.

2

-

-

... More
Supply & fixing in replacement bushing rod  suitable for 1250 Amps VMX type VCB trolly ,11 KV,complete all as specified and as directed by Engineer In Charge.                                                                                                                            

2

-

-

... More
Supply & fixing emergency charging handle for motor mechanism suitable for 1250/630 Amps VMX type VCB trolly,11 KV complete all as specified and as directed by Engineer In Charge.   

3

-

-

... More
Supply & fixing in replacement auxiliary Relay 220 Volts suitable for control panel of 66 KV power transformer No-1 complete all as specified and as directed by Engineer In Charge.

1

-

-

... More
Supply & fixing in replacement auxiliary Relay 3 Flags 220 Volts suitable for control panel of 66 KV power transformer No-3 complete all as specified and as directed by Engineer In Charge.

1

-

-

... More
Supply & fixing in replacement triping coil assy 220-250 Volt DC suitable for 66 KV main MRS SF-6 breakar, complete all as specified and as directed by Engineer In Charge                                                         

1

-

-

... More
Supply & fixing in replacement auxiliary switch 220-250 Volt, 66 KV existing type suitable for 66 KV SF- 6 breakar main incommer complete all as specified and as directed by Engineer In Charge.

1

-

-

... More
Supply & fixing in replacement of PVC insulated Armoured copper cable 12 Core 2.5 Sqmm,complete all as specified and as directed by Engineer In Charge                                                         

200

-

-

... More
Supply and fixing in replacement of PVC insulated FRLS weather proof cpper cable 4 Core 2.5 Sqmm,complete all as specified and as directed by Engineer In Charge.

100

-

-

... More
Supply and fixing in replacement of CT terminals complete all as specified and as directed by Engineer- in- Charge

80

-

-

... More
Supply & fixing in replacement Current transformer  (Apoxy) suitable for HT 11 KV  Incoming feeder  900-450/.577-1-1 Amps for protection with STR (short time rating ) of 18.4 KA for 1 sec, complete all as specified and as directed by Engineer In Charge. 

6

-

-

... More
Supply and fixing DC volt meter 0-600 Volt DC Complete all as specified and as directed by Engineer-in-Charge.

3

-

-

... More
Supply and fixing twin core sheathead multistrand copper cable 4 sqmm for DC protection system to VCB complete all as specified and as directed by Engineer-in-Charge.

83

-

-

... More
Supply and installation of battery bank 220 volt DC with sealed maintenance free,dry cell battery 2 volt DC of capacity 120 AH-110 Nos fitted in intercennecting links & iron anle rack complete all as specified and as directed by Engineer-in-Charge.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.