Military Engineer Services Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 7,16,000Document Cost
₹ 3,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_682003_1Tender No
CEWAC/HAL/T-16/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Completion of balance work and rectification of defects for construction of Block of PARKING SHED 4/2 WHEELER FOR TECH FLT HANGER complete all as specified and shown on drawing. Quantum of approx balance works to be completed 1.20 % for detail refer to Annexure -A2 (1st shed)
1
-
-
Completion of balance work and rectification of defects for construction of Block of PARKING SHED 4/2 WHEELER FOR TECH FLT HANGER complete all as specified and shown on drawing. Quantum of approx balance works to be completed 1.00 % for detail refer to Annexure -A2 (2nd shed near Hanger)
1
-
-
Completion of balance work and rectification of defects for construction of Block of Brake Parachute bay for SES section complete all as specified and shown on drawing. Quantum of approx balance works to be completed 18.90 % for detail refer to Annexure -A2
1
-
-
Completion of balance work and rectification of defects for construction of Block of PARKING SHED 4/2 WHEELER FOR (BRAKE PARACHUTE BAY) complete all as specified and shown on drawing. Quantum of approx balance works to be completed 2.70 % for detail refer to Annexure -A2
1
-
-
Completion of balance work and rectification of defects for construction of Block of (EJECTION SEAT SERVICING AND STORAGE BAY complete all as specified and shown on drawing. Quantum of approx balance works to be completed 13.00 % for detail refer to Annexure -A2
1
-
-
Completion of balance work and rectification of defects for construction of Block of ASV PARKING BAY complete all as specified and shown on drawing. Quantum of approx balance works to be completed 2.00 % for detail refer to Annexure -A2
1
-
-
Completion of balance work and rectification of defects for construction of Block of ASV SHED complete all as specified and shown on drawing. Quantum of approx balance works to be completed 3.00 % for detail refer to Annexure -A2
1
-
-
Completion of balance work and rectification of defects for construction of Block of ASV SERVICING BAY complete all as specified and shown on drawing. Quantum of approx balance works to be completed 11.00 % for detail refer to Annexure -A2
1
-
-
Completion of balance work and rectification of defects for construction of Block of EXTENSION OF AVIONICS LAB AND EW LAB INCLUDING PARKING complete all as specified and shown on drawing. Quantum of approx balance works to be completed 3.75 % for detail refer to Annexure -A2
1
-
-
Completion of balance work and rectification of defects for construction of Block of POD LAB AND EW LAB INCLUDING PARKING complete all as specified and shown on drawing. Quantum of approx balance works to be completed 10.50 % for detail refer to Annexure -A2
1
-
-
Completion of balance work and rectification of defects for construction of Block of FSS BLDG complete all as specified and shown on drawing. Quantum of approx balance works to be completed 9.00 % for detail refer to Annexure -A2
1
-
-
Completion of balance work and rectification of defects for construction of Block of BRIEFING ROOM complete all as specified and shown on drawing. Quantum of approx balance works to be completed 100 % for detail refer to Annexure -A2
1
-
-
Completion of balance work and rectification of defects for construction of Block of SUB STATION BLDG FOR AVIONIC LAB complete all as specified and shown on drawing. Quantum of approx balance works to be completed 5.70 % for detail refer to Annexure -A2
1
-
-
Completion of balance work and rectification of defects for construction of Block of SUB STATION BLDG FOR FSS BLDG complete all as specified and shown on drawing. Quantum of approx balance works to be completed 9.00 % for detail refer to Annexure -A2
1
-
-
Completion of balance work and rectification of defects for construction of Block of SUB STATION BLDG FOR EJECTION SEAT BAY BLDG complete all as specified and shown on drawing. Quantum of approx balance works to be completed 6.00 % for detail refer to Annexure -A2
1
-
-
Completion of balance work and rectification of defects for construction of Block of SUB STATION BLDG FOR POD LAB BLDG complete all as specified and shown on drawing. Quantum of approx balance works to be completed 7.50 % for detail refer to Annexure -A2
1
-
-
Completion of balance work and rectification of defects for construction of Block of SUB STATION BLDG FOR BRIEFING ROOM complete all as specified and shown on drawing. Quantum of approx balance works to be completed 59.70 % for detail refer to Annexure -A2
1
-
-
Completion of balance work and rectification of defects for construction of Block of AC PLANT ROOM FOR AVIONIC LAB complete all as specified and shown on drawing. Quantum of approx balance works to be completed 7.55 % for detail refer to Annexure -A2
1
-
-
Completion of balance work and rectification of defects for construction of Block of AC PLANT ROOM FOR EJECTION SEAT BAY complete all as specified and shown on drawing. Quantum of approx balance works to be completed 9.40 % for detail refer to Annexure -A2
1
-
-
Completion of balance work and rectification of defects for construction of Block of AC PLANT ROOM FOR POD LAB complete all as specified and shown on drawing. Quantum of approx balance works to be completed 12.00 % for detail refer to Annexure -A2
1
-
-
Completion of balance work and rectification of defects for construction of Block of AC PLANT ROOM FOR FSS BLDG complete all as specified and shown on drawing. Quantum of approx balance works to be completed 7.60 % for detail refer to Annexure -A2
1
-
-
Completion of balance work and rectification of defects for construction of Block of AHU ROOM FOR AVIONIC LAB complete all as specified and shown on drawing. Quantum of approx balance works to be completed 4.15 % for detail refer to Annexure -A2
1
-
-
Completion of balance work and rectification of defects for construction of Block of AHU ROOM FOR FSS BLDG complete all as specified and shown on drawing. Quantum of approx balance works to be completed 5.80 % for detail refer to Annexure -A2
1
-
-
Completion of balance work and rectification of defects for construction of Block of AHU ROOM FOR FSS BLDG (AF NET END) complete all as specified and shown on drawing. Quantum of approx balance works to be completed 8.0 % for detail refer to Annexure -A2
1
-
-
Construction of Septic tank of 25 users including exc. in ordinary soil, PCC foundation, brick work in CM (1:4), RCC main hole cover, vent shaft and sludge chambers extra complete all as per specified.
5
-
-
Construction of Soakage well 2.4mtr dia x 6.0 mtr depth, excavation in ordinary soil, PCC in foundation, Honey combed and solid bk work in CM 1:4, RCC slab, filling with brick bats complete all as per specified.
5
-
-
NOTE: Schedule ‘A’ Part II to XII under are Prepriced by MES.
-
-
-
Lump sum price worked out by the Contractor for “EARTH WORK AND EXCAVATION” as listed in Schedule ‘A’ Part II
1
716935
-
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part III
1
83670
-
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part IV
1
71110
-
Lump sum price worked out by the Contractor for “ADDN/ALTN TO AVIONIC LAB" as listed in Schedule ‘A’ Part V
1
1770757
-
Lump sum price worked out by the Contractor for “FIRE FIGHTING ” as listed in Schedule ‘A’ Part VI
1
2274360
-
Lump sum price worked out by the Contractor for “FLAME PROOF WORK” as listed in Schedule ‘A’ Part VII
1
4526318
-
Lump sum price worked out by the Contractor for “LIGHTENING PROTECTION WORK” as listed in Schedule ‘A’ Part VIII
1
406199
-
Lump sum price worked out by the Contractor for “ROAD, PATH & CULVERT” as listed in Schedule ‘A’ Part IX
1
5864424
-
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part X
1
224602
-
Lump sum price worked out by the Contractor for “External Electirifcation” as listed in Schedule ‘A’ Part XI
1
1519975
-
Lump sum price worked out by the Contractor for “Sewage Disposal” as listed in Schedule ‘A’ Part XII
1
182599
-
Lump sum price worked out by the Contractor for “Area Drainage” as listed in Schedule ‘A’ Part XIII
1
1180612
-
Lump sum price worked out by the Contractor for “CONNECTING PASSAGE TO AVIONIC LAB” as listed in Schedule ‘A’ Part XIV
1
251062
-
Lump sum price worked out by the Contractor for “ADDN/ALTN TO ESS BLDG” as listed in Schedule ‘A’ PartXV
1
159778
-
NOTE: Schedule ‘A’ Part II to XII under are Prepriced by MES.
-
-
-
M&L for approved GSB Gd II filling 200 mm thick as in paving in layers not exceeding 15 cm incl spreading, watering all as specified and directed
212.97
-
-
M&L for WMM 150 thick for new construction of rigid pavement in two layers sub grade granite trap or basalt stone of grading 1 (75 mm thick each layer incl spreading and rolling with 8 to 10 Ton power road roller to required gradient and camber) over compacted complete all as specified.
212.97
-
-
M&L thermoplastic road marking paint(added reflective glass beads) as in lines , dashes, arrows, letters, etc on roads pavements and the like exc 10cm wide by mechanical means
370
-
-
S & F in stop valves, push type, 15mm bore cast copper alloy ,scrwed down ,chromium plated high pressure ( concealed type) ,with crutch or butterfly handle ,scrwed both ends for iron pipe or for union and fixed complete all as per specified.
13
-
-
S &F powder coated aluminium door made out of hollow extruded anodized aluminium section as mentioned below. Each door shall be provided with 02 Nos disc or D type aluminium handles 2 Nos tower bolt 200 mm long one brass mortician lock of six lever with key in duplicate and shall be regulated by providing double action hydraulic door floor spring (make sandhu/Ritz). Shutter shall be partly glazed with and including 5mm thick tinted beading/gasket anodized aluminium beading screws complete in all respects all as directed.
Chowkhat/frames 101.6x44.45x1.5mm thick Shutter top and bottom rails 114.3x44.45x1.5mm thick
Shutter middle rail 83.5x44.45x1.5mm thick
Shutter vertical rail/sytle 83.5x44.45x1.5 mm thick
Make:- (i) Anodized aluminium section : Jindal/Hindalco/Indalco.
(ii) PVC sheet: Rajshri/Sintex/Accuapoly.
(iii) Glass : Saint Gobin, Modiguard, TATA
31
-
-
S&F nylon rope 10mm dia of good quality complete all as specified and as directed
690
-
-
M&L for oiling and greasing of mild steel pullies at height of 12 mtr without removing pullies and making smooth and easy to function complete all as specified and as directed
20
-
-
Supply only ALLIED” ALUMINIUM ALLOY Tiltable Tower Extendable Telescopic, Square Type Ladder made out of SPECIAL Extruded, H.D Tested Quality ‘Hindalco’ make ALUMINIUM LADDER Sections of size 66mm(2.5/8”) x31mm (1.1/4”)x3mm (1/8”) thick approx. with steps made of ALUMINIUM Fluited pipes of 25mm (1”) dia approx. At a distance of 300mm (12”) complete with a set of Specially designed Rope pulleys and Winch arrangement with suitable size Steel Wire Rope for extending & closing the extended section of Ladder to any required height fabricated on M.S.Channel frames duly covered with 16 swg M.S.Sheet for carrying Materials and Four M.S. Forged Solid Rubber Casted Special Wheels with Double Ball Bearings of suitable dia complete with Tow Bar. The platform of size 2’x2’ on the top guarded from three sides will be provided for safe working. Further the Ladder may be provided with Mechanical System to tilt the complete Ladder on rest and again lift the same for working having Addl. Winch Set complete with required M.S.Pulleys and steel wire rope to enable to reduce extra manpower to handle the Ladder.
2
-
-
Supply, installation, commessioning and testing transformer step down indoor type floor mounted, copper wound 3 phase 50 Hz, vector delta star oil cooled primary voltage 11000 volt, secondary voltage 433 volt 3 phase wire with off load tap changer on primary side to vary secondary voltage (+/-) 7.5% of capacity 630 KVA (for composite Pod Lab) complete with standard fittings including first fill of transformer oil all as per IS 1180 (Part-I) complete all as specified and directed by Engineer-in-Charge including the following :-
(a) Breather filled with silicagel
(b) Oil temp guage
(c) Oil conservator tank with oil level indicator
(d) Explosion vent/saftey release valve
(e) Filling/drain and sampling valve
(f) Air release valve.
(g) B1 Directional roller
(h) Name plate showing vector group/Tap changer system with voltage variation.
1
-
-
Supply, installation, commessioning and testing transformer step down indoor type floor mounted, copper wound 3 phase 50 Hz, vector delta star oil cooled primary voltage 11000 volt, secondary voltage 433 volt 3 phase wire with off load tap changer on primary side to vary secondary voltage (+/-) 7.5% of capacity 250 KVA (for Avionics Lab) complete with standard fittings including first fill of transformer oil all as per IS 1180 (Part-I) complete all as specified and directed by Engineer-in-Charge including the following :- (a) Breather filled with silicagel
(b) Oil temp guage
(c) Oil conservator tank with oil level indicator
(d) Explosion vent/saftey release valve
(e) Filling/drain and sampling valve
(f) Air release valve.
(g) B1 Directional roller
(h) Name plate showing vector group/Tap changer system with voltage variation.
1
-
-
Supply, installation, commessioning and testing transformer step down indoor type floor mounted, copper wound 3 phase 50 Hz, vector delta star oil cooled primary voltage 11000 volt, secondary voltage 433 volt 3 phase wire with off load tap changer on primary side to vary secondary voltage (+/-) 7.5% of capacity 200 KVA (for FSS, ASV & Existing Hanger - 01; Brake Parachute & Ejection Seat Bay - 01 No and for briefing Hall - 01 No) complete with standard fittings including first fill of transformer oil all as per IS 1180 (Part-I) complete all as specified and directed by Engineer-in-Charge including the following :- (a) Breather filled with silicagel
(b) Oil temp guage
(c) Oil conservator tank with oil level indicator
(d) Explosion vent/saftey release valve
(e) Filling/drain and sampling valve
(f) Air release valve.
(g) B1 Directional roller
(h) Name plate showing vector group/Tap changer system with voltage variation.
3
-
-
Supply, installation, testing and commissioning of 11KV 630 Amps, 26.2KA for extensible IP-54 outdoor type SF-6 gas insulated 630 Amps compact switch gear RMU comprising of 1 incoming isolator, 2 outgoing VCB & 1 Bus PT Panel as detail below. The VCB shall be enclosed in robotically welded SS tank filled with SF6 with IP-67, leak rate less than 0.1% and tested as per latest IEC 62271-200. The coupling of unit shall be with bolted bus bar with bushings on the top of tank duly insulated with right angle boots to ensure reliability. The unit shall include the following with all necessary standard fitting required at site :-
(a) Load break switch module - incoming - 01 No. Manual/motor operated 11KV, 630 Amps three position load break switch with disconnector and earthing switch, Motor control voltage 24V DC. (b) Operating mechanism with two separate operating shaft for load break function and earthing function.
(c) Cable boxes should be Arc proof with hinged door and interlocked with respective earthing switches. For safety of operator it should not be possible to open the cable box unless the earth switch is ON.
(d) Vacuum circuit breaker module outgoing - 02 Nos. Manual/Motor operated fixed type 630 Amps vacuum circuit breaker with stored spring meter.
4
-
-
Supply, Installation, testing and commissioning HT 11 KV, 3 Phase, 50 Hz, 3 wire, totally enclosed, metal clad, prewired, extensible type, indoor type, floor mounted, Horizontal draw out, horizontal isolation type vaccum circuit breaker (VCB) 630 Amp rating, in extension to the existing VCB panel board by making necessary modification, connecting with bus bar of appropriate capacity duly insulated motor operated, spring charged having rupturing capacity 350 MVA , comprising of the followings :- (a) Housing for circuit breaker carriage 1 No (b) Mechanical inter lock and automatic safety shutter gear including padlocking arrangement 1 No (c) Isolating plugs 6 Nos (d) 18.4 KA at 11 KV, 630 Amps VCB comprising of the following :- (i) Assembly of 3 vacuum interrupters complete with epoxy support insulators and self aligning finger type isolating contacts. (ii) Hand and motor operated (220 AC) spring charged, independent starting crossing/tripping trip free operating mechanism with manual closing and tripping push buttons and mechanical break closed/open spring charged/discharged indication (contd.)
1
-
-
All as described in Srl item No. 7.06 here-in-before, but rupturing capacity 350MVA of rating upto 400 Amps
2
-
-
Supply, installation, commissioning and testing silent diesel engine driven Generating Set 625 KVA (500KW at 0.8 PF) capacity 415 Volts, 3 phase, 4 wire, & with including acoustic weather proof enclosure as per CPCB norms and noise level shall not be exceeding 75 db at a distance of 1 metre from all sides, complete in all respects & comprising the following components : (a) Diesel Engine developing suitable BHP at 1500 RPM conforming to BS 5514/ISO0346 series inclusive of the following accessories:-
(i) Radiator and Radiator fan
(ii) Spider coupling guard
(iii) Fly wheel
(iv) Air cleaner dry type.
(i) Fuel and lubricant oil filter.
(v) By-pass filter
(vi) Coolant inhibitor
(vii) Fuel pump DTR type/in line mono block fuel injecting pump.
(viii) Water pump
(ix) Lub oil pump and inclusive of first filling of lubricant oil & coolant. (x) Electric starter 12/24 Volts DC as manufacturer's design.
(xi) Battery charging generator (DC alternator)
(xii) Residential silencer
(xiii) Lubricant oil cooler(xiv) Flexible pipe for silencer (xv) DC volt meter
(xvi) Water temperatures gauge lub oil pressure gauge
(xvii) Speedo meter and Engine running hours meter
1
-
-
(xviii) Display for fault
(xix) Suitable size of turbo-charger (xx) Shut off coil with safeties for LLOP/HWT.
(xxi) Mechanical Governor.
(xxii) Maintenance free secondary batteries 180 AH 12 Volts as per manufacture design. (B) Alternator:- Synchronous alternator 750 KVA, 1500rpm, 415 Volts, 50Hz, 3 phase system, brushless type, screen protected revolving filled self excited, regulated, confirming to IS 4772 of 1992/BS 500. (C) AMF panel of suitable size factory made outdoor cubical type form open cable fabricated out of CRCA steel sheet 3.15 mm thick complete as per manufacturer's specification suitable for DG set of capacity 750 KVA grouted in floor with PCC 1:2:4 type B-2 foundation of suitable size and comprising of the following switch gears and accessories (PCC measured and paid seperately) (i) Contactor ML of suitable capacity (ii) Copper bus bar of current rating 1500 Amp
(iii) sensitivity relay set with suitable CTs(iv) Electronic latch circuit with tripping indication
(v) Instantaneous tripping device for complete panel over current 0.5 AMP.(vi) Reset facilities for complete protection of AMF Panel
(vii) Self sequential starting relay unit 12 Volts DC complete with alarm contactor with suitable Amps.
-
-
-
All as described in Srl item No. 7.10 here-in-before, but 250 KVA with suitable capacity of MCCB (for Avionics Lab)
1
-
-
All as described in Srl item No. 7.10 here-in-before, but 200 KVA with suitable capacity of MCCB (for FSS, ASV & Existing Hangar / Brake Parachute & Ejection Seat Bay / Briefing Hall)
3
-
-
Supply, installation, commissioning and testing factory made electric panel board as per IS-8632, dust, weather and vermin proof, 415V, 3 Phase, Indoor type, Floor mounted, made out of 2 mm thick mild steel CRCA sheet and angle iron frame using size 50x50x6 mm angle iron frame fixed in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate, cable entry boxes with cable gland, front double shutter with locking arrangement, epoxy powder coated and comprising following :- (Loc : Avionics Lab Sub Station)
(a) Aluminum bus bar of 1000 Amps size mounted on insulators – 04 Nos (b) Volt meter, 0-500V, 3 phase, digital type with selector switch – 01 No (c) Ammeter digital type with CTs – 01 No (d) Indicating lamps – 03 Nos Incoming : MCCB 4 P 630A, 35 KA - 01 No
Outgoing : MCCB 4 P 200A, 25 KA - 01 No, MCCB 4 P 160A, 25 KA - 01 No, MCCB 4 P 125A, 25 KA - 01 No, MCCB 4 P 16A, 25 KA - 01 No & MCB SPN 20A, 16 KA - 01 No
1
-
-
Supply, installation, commissioning and testing factory made electric panel board as per IS-8632, dust, weather and vermin proof, 415V, 3 Phase, Indoor type, Floor mounted, made out of 2 mm thick mild steel CRCA sheet and angle iron frame using size 50x50x6 mm angle iron frame fixed in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate, cable entry boxes with cable gland, front double shutter with locking arrangement, epoxy powder coated and comprising following :- (Loc : Composit Lab Sub Station)
(a) Aluminum bus bar of 1500 Amps mounted on insulators – 04 Nos (b) Volt meter, 0-500V, 3 phase, digital type with selector switch – 01 No (c) Ammeter digital type with CTs – 01 No (d) Indicating lamps – 03 Nos Incoming : ACB 4 P 1000A, 50 KA - 01 No
Outgoing : MCCB 4 P 630A, 35 KA - 01 No, MCCB 4 P 160A, 25 KA - 01 No, MCCB 4 P 63A, 25 KA - 01 No & MCCB 4 P 16A, 25 KA - 01 No
1
-
-
Supply, installation, commissioning and testing factory made electric panel board as per IS-8632, dust, weather and vermin proof, 415V, 3 Phase, Indoor type, Floor mounted, made out of 2 mm thick mild steel CRCA sheet and angle iron frame using size 50x50x6 mm angle iron frame fixed in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate, cable entry boxes with cable gland, front double shutter with locking arrangement, epoxy powder coated and comprising following :- (Loc : Ejection Seat Bay Sub Station)
(a) Aluminum bus bar of 600 Amps mounted on insulators – 04 Nos (b) Volt meter, 0-500V, 3 phase, digital type with selector switch – 01 No (c) Ammeter digital type with CTs – 01 No (d) Indicating lamps – 03 Nos Incoming : MCCB 4 P 400A, 35 KA - 01 No
Outgoing : MCCB 4 P 250A, 25 KA - 01 No, MCCB 4 P 100A, 25 KA - 01 No, MCCB 4 P 63A, 25 KA - 01 No, MCCB 4 P 16A, 25 KA - 01 No & MCB SPN 20A, 16 KA - 01 No
1
-
-
Supply, installation, commissioning and testing factory made electric panel board as per IS-8632, dust, weather and vermin proof, 415V, 3 Phase, Outdoor type, Floor mounted, made out of 3.15 mm thick mild steel CRCA sheet and angle iron frame using size 50x50x6 mm angle iron frame fixed in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate, cable entry boxes with cable gland, front double shutter with locking arrangement, epoxy powder coated and comprising following :- (Loc : Near SES Bldg)
(a) Aluminum bus bar of 600 Amps mounted on insulators – 04 Nos (b) Volt meter, 0-500V, 3 phase, digital type with selector switch – 01 No (c) Ammeter digital type with CTs – 01 No (d) Indicating lamps – 03 Nos Incoming : MCCB 4 P 400A, 35 KA - 01 No
Outgoing : MCCB 4 P 250A, 25 KA - 01 No, MCCB 4 P 100A, 25 KA - 01 No, MCCB 4 P 63A, 25 KA - 01 No, MCCB 4 P 16A, 25 KA - 01 No & MCB SPN 20A, 16 KA - 01 No
1
-
-
Supply, installation, commissioning and testing factory made electric panel board as per IS-8632, dust, weather and vermin proof, 415V, 3 Phase, Indoor type, Floor mounted, made out of 2 mm thick mild steel CRCA sheet and angle iron frame using size 50x50x6 mm angle iron frame fixed in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate, cable entry boxes with cable gland, front double shutter with locking arrangement, epoxy powder coated and comprising following :- (Loc : FSS Sub Station)
(a) Aluminum bus bar of 600 Amps mounted on insulators – 04 Nos (b) Volt meter, 0-500V, 3 phase, digital type with selector switch – 01 No (c) Ammeter digital type with CTs – 01 No (d) Indicating lamps – 03 Nos Incoming : MCCB 4 P 400A, 35 KA - 01 No
Outgoing : MCCB 4 P 125A, 25 KA - 02 Nos, MCCB 4 P 100A, 25 KA - 01 No, MCCB 4 P 32A, 25 KA - 04 Nos
1
-
-
Supply, installation, commissioning and testing factory made electric panel board as per IS-8632, dust, weather and vermin proof, 415V, 3 Phase, Indoor type, Floor mounted, made out of 2 mm thick mild steel CRCA sheet and angle iron frame using size 50x50x6 mm angle iron frame fixed in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate, cable entry boxes with cable gland, front double shutter with locking arrangement, epoxy powder coated and comprising following :- (Loc : Briefing Hall Sub Station)
(a) Aluminum bus bar of 400 Amps mounted on insulators – 04 Nos (b) Volt meter, 0-500V, 3 phase, digital type with selector switch – 01 No (c) Ammeter digital type with CTs – 01 No (d) Indicating lamps – 03 Nos Incoming : MCCB 4 P 250A, 25 KA - 01 No
Outgoing : MCCB 4 P 160A, 25 KA - 02 Nos, MCCB 4 P 63A, 25 KA - 01 No, MCCB 4 P 32A, 25 KA - 01 No
1
-
-
S&F LED post top lantern luminaire 36 watt complete with all accessories, die cast aluminum housing and acrylic cover, IP 65 ingress protection all as specified and directed by Engineer-in-Charge
12
-
-
S&F LED street light luminaire 45 watt complete with all accessories, die cast aluminum housing and toughened glass cover having efficacy up to 100 lm/watt with modular top up lenses, surge protection @ 4 KV internal, 8 KV external to driver IP 66 ingress protection all as specified and directed
24
-
-
S & F LED aviation obstruction light twin lamp 36 watt with die cast aluminum body and toughened red heat resistant glass cover complete with all accessories all as specified and directed.
4
-
-
Supply, Fixing and Testing Voltage Stablizer servo control for automatic operation 3 phase naturally oil cooled , indoor type, designed for input of 300 volts to 480 volts with output voltage stablized at 415 volts, 50 Hz with accuracy (+/-) 1% and speed correctin 8 V per second of capacity 630 KVA (for Composit Lab) including all standed fittings and first oil fil complete all as specified and directed by Engr-in-Charge.
1
-
-
Supply, Fixing and Testing Voltage Stablizer servo control for automatic operation 3 phase naturally oil cooled , indoor type, designed for input of 300 volts to 480 volts with output voltage stablized at 415 volts, 50 Hz with accuracy (+/-) 1% and speed correctin 8 V per second of capacity 250 KVA (for avionics Lab) including all standed fittings and first oil fil complete all as specified and directed by Engr-in-Charge.
1
-
-
Supply, Fixing and Testing Voltage Stablizer servo control for automatic operation 3 phase naturally oil cooled , indoor type, designed for input of 300 volts to 480 volts with output voltage stablized at 415 volts, 50 Hz with accuracy (+/-) 1%5 and speed correctin 8 V per second of capacity 200 KVA (01 each for Ejection Seat Bay, FSS & Briefing Hall Sub Stations) including all standed fittings and first oil fil complete all as specified and directed by Engr-in-Charge.
3
-
-
Supply, installing and commissioning of 1500 Amps air insulated compact rising main on vertical/horizontal bracket duly grouted on wall of suitable size made of 1.6mm GI sheet duly powder coated, 4P aluminium bus bar in conveient sections with support of F-Insulators at suitable distance, having short circuit 10KA for 1 sec, suitable for 415V, 50 Hz, AC including fire barriers, End cover, connection pieces duly screwed with nut, bolts of suitable size and 2 runs of external aluminium earhing all as specified and directed by Engineer-in-Charge.
32
-
-
M&L for Drilling (horizontally) existing road/Taxi/Runway suitable for GI tubing of 100 mm dia all as specifed and directed including drawing 100 mm dia medium grade HDPE pipe of 6 kg /cm2 pressure all as specified and directed by Engr-in-Charge.
64
-
-
Supply, installation, testing and commissioning of factory made, stand alone type automatic power factor correction (APFC) panel, LT, AC, 50 Hz, 440 volts, 3 phase 4 wire system, indoor type with IP42 ingress protection, suitable for auto and manual operation options, compartmentalized, fabricated out of 2mm thick crca sheet steel and 40 mm x 40 mm x 6 mm thick angle iron frame, dust and vermin proof well ventilated, powder coated with seven tank process, all accessories pre-wired with single core, PVC insulated, 1.5/2.5 sqmm, copper conductor, FRLSH cable, 04 nos electrolytic aluminium bus bars of 300 amp rating fixed on ebonite insulators all as specified and directed and comprising of the followings:- A) Automatic power factor controller relay six steps for switching ‘on’ and ‘off’ capacitor bank with voltage visual alarm if units fails to achieve required power factor, automatic lock out of faulty steps and display of power factor achieved - 01 No B) APP type (hazy polypropelne film as dielectric material and aluminum foil as electrode) capacitor of rating 20 KVar conforming to relevant IS – 01 no
1
-
-
Supply, installation, testing and commissioning of factory made, stand alone type automatic power factor correction (APFC) panel, LT, AC, 50 Hz, 440 volts, 3 phase 4 wire system, indoor type with IP42 ingress protection, suitable for auto and manual operation options, compartmentalized, fabricated out of 2mm thick CRCA sheet steel and 40 mm x 40 mm x 6 mm thick angle iron frame, dust and vermin proof well ventilated, powder coated with seven tank process, all accessories pre-wired with single core, pvc insulated, 1.5/2.5 sqmm, copper conductor, FRLSH cable, 04 nos electrolytic aluminium bus bars of 200 amp rating fixed on ebonite insulators all as specified and directed and comprising of the followings:- A) Automatic power factor controller relay five steps for switching ‘on’ and ‘off’ capacitor bank with voltage visual alarm if units fails to achieve required power factor, automatic lock out of faulty steps and display of power factor achieved – 01 no
B) APP type (hazy polypropelne film as dielectric material and aluminum foil as electrode) capacitor of rating 10 KVar conforming to relevant is – 02 nos
1
-
-
Supply, installation, testing and commissioning of factory made, stand alone type automatic power factor correction (APFC) panel, LT, AC, 50 hz, 440 volts, 3 phase 4 wire system, indoor type with ip42 ingress protection, suitable for auto and manual operation options, compartmentalized, fabricated out of 2mm thick CRCA sheet steel and 40 mm x 40 mm x 6 mm thick angle iron frame, dust and vermin proof well ventilated, powder coated with seven tank process, all accessories pre-wired with single core, pvc insulated, 1.5/2.5 sqmm, copper conductor, FRLSH cable, 04 nos electrolytic aluminium bus bars of 150 amp rating fixed on ebonite insulators all as specified and directed and comprising of the followings:- A) automatic power factor controller relay four steps for switching ‘on’ and ‘off’ capacitor bank with voltage visual alarm if units fails to achieve required power factor, automatic lock out of faulty steps and display of power factor achieved – 01 no
B) APP type (hazy polypropelne film as dielectric material and aluminum foil as electrode) capacitor of rating 10 KVar conforming to relevant is – 01 nos
1
-
-
Supply, installation, testing and commissioning of factory made, stand alone type automatic power factor correction (APFC) panel, LT, AC, 50 Hz, 440 volts, 3 phase 4 wire system, indoor type with IP42 ingress protection, suitable for auto and manual operation options, compartmentalized, fabricated out of 2mm thick CRCA sheet steel and 40 mm x 40 mm x 6 mm thick angle iron frame, dust and vermin proof well ventilated, powder coated with seven tank process, all accessories pre-wired with single core, PVC insulated, 1.5/2.5 sqmm, copper conductor, FRLSH cable, 04 nos electrolytic aluminium bus bars of 750 amp rating fixed on ebonite insulators all as specified and directed and comprising of the followings:- A) Automatic power factor controller
Relay ten steps for switching ‘on’ and ‘off’ capacitor bank with voltage visual alarm if units fails to achieve required power factor, automatic lock out of faulty steps and display of power factor achieved – 01 no
B) APP type (hazy polypropelne film as dielectric material and aluminum foil as electrode) capacitor of rating 25 KVar conforming to relevant is – 05 nos
1
-
-
M&L for earthing with copper earth plate electrode 600 x 600 x 5 mm thick buried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to copper strip of size 32 x 6 mm as earthing lead by means of nut, bolts and washers made out of galvanised ireon or mild steel and 40 mm dia GI pipe light grade for protection of earth lead and connected to transformer neutral or as directed by engineer -in-charge including PCC pit in cement concrete 1:3:6 (20 mm graded stone aggregate) and RCC cover of size 450x450x50mm in RCC 1:2:4 (20mm graded stone aggregate) reinforced with and including 8.0mm dia TMT bars @ 100mm centre to centre both ways, galvanised iron wire mesh, funnel, galvanised iron watering pipe 20mm bore (dia) medium grade, necessary excavation in any strata of soil, returning, filling in and removal of surplus spoil upto a distance of 50 mtr and all as shown in electrical plate no. 3 of MES standard schedule Part-I - 2009 and testing on completion, complete all as specified and as directed..
20
-
-
Supplying & laying centrifugally cast (spun) ductile iron pressure pipe of 150mm bore size with socket & spigot ends having ISI stamping marking with IS 8329/2000,classification K9 in standard length of 5.50/6.0 mtrs,suitable for and including push on joint (gasket 'D' jointing) with cement mortar lining,complete all as specified :-
200
-
-
Ductile iron fittings such as bends (any type radius and angle) Tapers any type (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch 'Y' junction. Double branch, cross (all sockets or socket and spigot) collars, tail pieces with one end flanged (integrally cast) and one end socket. Spigot caps and plugs suitable for 100 to 150 mm bore ducitle iron pressure pipes, of K-9 classification and push on flexible rubber gasket joints complete all as specified. Note: (i) The weight of the fittings shall be measured and paid as given in relevant IS or actually provided which ever is less.
(ii) All fittings shall bear relevant IS stamping marking
(iii) Excavation and earth work shall be measured and paid for separately
(iv) Cost of the joints and jointing materials shall be deemed to be included in the relevant items of DI/CI pipes here-in-before.
90
-
-
S&F cast iron sluice valve 150 mm dia of non rising type both ends flanged and drilled holes 1.0 PN complete with steel metal spindle and nuts and bolts and gaskets comforming to IS-780-01
1
-
-
S&F cast iron sluice valve 80 mm dia of non rising type both ends flanged and drilled holes 1.0 PN complete with steel metal spindle and nuts and bolts and gaskets comforming to IS-780-01
3
-
-
M & L brick masonary valve pit size 1.5 x 1.5 x 1.5 mtrs (internal size) with MS sheet cover 3 mm thick and angle iron frame of size 50 x 50 x 3 mm with locking arrangement duly painted with two coat of synthetic enamel paint over a coat of red oxide primer complete including excavation in any type of soil, returning,filling in and removing surplus excavated material not exceeding 50 mtrs, all as specified brick work and all inner sides of pit and exposed portion of out side shall be plastered in cement mortor (1:4) complete all as specified.
1
-
-
M & L brick masonary valve pit size 0.90 x 0.90 x 0.90 mtrs (internal size) with MS sheet cover 3 mm thick and angle iron frame of size 50 x 50 x 3 mm with locking arrangement duly painted with two coat of synthetic enamel paint over a coat of red oxide primer complete including excavation in any type of soil, returning,filling in and removing surplus excavated material not exceeding 50 mtrs, all as specified brick work and all inner sides of pit and exposed portion of out side shall be plastered in cement mortor (1:4) complete all as specified.
3
-
-
Supply and fixing steel tubing, light grade, galvanised with all fittings, 15mm bore, 1.50m long on the roof by making base of PCC 1:2:4, type B-1 of 300mm x 300mmx300mm for air termination rod complete all as specified and directed by Engineer-in-charge. (Note : cost of PCC block shall be deemed to be included in the unit rate quoted for item).
344
-
-
Supply and fixing 32 mm x 6 mm GI strip as earth continuity conductor or main earthing lead fixed to wall / pole or buried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc all as specified and directed.
400
-
-
S&F MCB SP 6 Amp 10KA complete all as specified and as directed
48
-
-
S & F testing and commissioning of MICRO processor with digital display fire control panel with single panel of capacity for 99 detectors & 99 modules upto 200 detector & modules fitting with automatic battery charger including maint free battery, including lamp with all connected accessories, suitable for 1 zone
9
-
-
S & F testing and commissioning of MICRO processor with digital display fire control panel with single panel of capacity for 99 detectors & 99 modules upto 200 detector & modules fitting with automatic battery charger including maint free battery, including lamp with all connected accessories, suitable for 2 zone
3
-
-
S & F testing and commissioning of MICRO processor with digital display fire control panel with single panel of capacity for 99 detectors & 99 modules upto 200 detector & modules fitting with automatic battery charger including maint free battery, including lamp with all connected accessories, suitable for 8 zone
1
-
-
Supply & fix flame proof flood light luminaries suitable for HID lamp of 250 watt compress of body made out of cast aluminium alloy LM6 luminaire spun aluminum reflector fitted inside main body, heat resistant toughend glass cemented to cast aluminium, retainging ring fixed to main body, mounted on MS galvanised iron cradle and base plate for rotating in horizontal and vertical planes, luminiarie with lamp holder, main connector suitable up to 6 Sqmm incoming cable and earthing terminal one internal and 2 external of size M6x12mm finish in stove enamel including 250 watt MH lamp incl control gear complete and certified and tested by CAssessedI Dhanbad
6
-
-
All as above as per item No 11.01 but of cap 150 watt MH lamp complete.
2
-
-
Supply and fix Flame Proof Air circulator fans 230 volt single pase oscillating 760 mm sweep suitable for wall mounting
9
-
-
Supply and fix Flame Proof exhaust fans AC three phase 415 V of size 450 mm sweep with louver, all as specified and as directed.
7
-
-
Supply and fix flame proof weather proof DB TPN 415 Volts 04 way with bus bar in cast aluminium LM-6 encloser operated externally spring type knob complete with M-25 cable entry to suit incomming cable and 2 nos M-20 cable entries for out going cable from bottom with cable glands suitable for hazardous area and confirming to IS-2147/62 neoprene gasket degree of protection IP-65 all as per directed and specified.
3
-
-
Supply and fix flame proof weather proof DB SPN 415 Volts 12 way with bus bar in cast aluminium LM-6 encloser operated externally spring type knob complete with cable glands suitable for hazardous area and confirming to IS-2147/62 neoprene gasket degree of protection IP-65 all as per directed and specified.
8
-
-
Supply and fix flame proof weather proof DB SPN 415 Volts 8 way with bus bar in cast aluminium LM-6 encloser operated externally spring type knob complete with cable glands suitable for hazardous area and confirming to IS-2147/62 neoprene gasket degree of protection IP-65 all as per directed and specified.
2
-
-
All as per item No 11.07 above but DB SPN 4 Way, all as specified.
3
-
-
Supply and fix MCCB TPN 100 A 10 KA capacity, all as specified and as directed.
3
-
-
Supply and fix MCB TPN 63 A 10 KA capacity, all as specified and as directed
3
-
-
Supply and fix MCB SPN 40 A, all as specified and directed
13
-
-
Supply and fix MCB SP 06 to 32 A, all as specified and as directed
98
-
-
Supply and fixing 4.0 mm dia GI or steel wire, as earth continuity conductor or main earthing lead fixed to wall / pole or buried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc all as specified and directed.
50
-
-
Supply and fix MCB SP 06 to 32 A, all as specified and as directed
175
-
-
M&L for providing and applying two coats of 4mm thick PYPKOTE antirust protection including primer and lap of 150mm bore MS pipe complete including surface prepartation coating and wrapping shall be conforming to IS 10221 including conduction hydraulic test all as specified and directed.
138
-
-
Supply, erection and installation of Fire Hose Cabinet to be mounted externally near the Hydrant Post fabricated from 16 SWG MS Steel of appox size 900mmx 600mmmx300mm with a canopy, door with 4mm glass encased in heavy grade rubber beading, a key box in built in the box, suitable to accomodate one hydrant valve, one branch noxxle and two 15 mtrs hose, weather proof, Finished with P.O fire red color (Sample to be approved prior to entire supply) complete all as specified and directed.
19
-
-
Supplying , laying and jointing NP2 class (heavy duty) RCC pipes of 300 mm bore with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement:2 fine sand) including 1:3:6 cement concrete all round 100mm thick complete all as specified and directed.
145
-
-
SUPPLY AND FIXING CEILING FAN 1400MM SWEEP 5 STAR RATED COMPLETE WITH DOWN ROD, BLADES WITH FLEXIBLE WIRE THREE CORE 23/0.0076 FOR ELECTRIC CONNECTION FROM CEILING ROSE TO CONNECTOR ALL AS SPECIFIED AND DIRECTED
17
-
-
SUPPLY AND FIXING EXHAUST FAN 300MM SWEEP COMPLETE WITH SHUTTER AND LOUVERS, STEEL BODY, 23/0.0076 FLEXIBLE THREE CORE WIRE FOR ELECTRICAL CONNECTION FROM CEILING ROSE TO FAN ALL AS SPECIFIED AND DIRECTED
16
-
-
SUPPLY AND FIXING EXHAUST FAN 450MM SWEEP COMPLETE WITH SHUTTER AND LOUVERS, STEEL BODY, 23/0.0076 FLEXIBLE THREE CORE WIRE FOR ELECTRICAL CONNECTION FROM CEILING ROSE TO FAN, ALL AS SPECIFIED AND DIRECTED
10
-
-
SUPPLY AND FIXING LIGHT FITTING 1X18W LED TYPE WITH WALL/SURFACE MOUNTED BOX TYPE EPOXY POWDER COATED WITH COMPLETE ACCESSORIES INCLUDING TUBE ROD/LED ALL AS DIRECTED
34
-
-
SUPPLY AND FIXING LIGHT FITTING 2X18W LED TYPE WITH WALL/SURFACE MOUNTED BOX TYPE EPOXY POWDER COATED WITH COMPLETE ACCESSORIES INCLUDING TUBE ROD ALL AS DIRECTED
23
-
-
SUPPLY AND FIXING WALL MOUNTED LED LIGHT FITTING 1X11W INCLUDING 11W LED LAMP COMPLETE ALL AS SPECIFIED AND DIRECTED
17
-
-
SUPPLY AND FIXING LED TYPE WALL MOUNTED SECURITY LIGHT FITTING 45W LED TYPE COMPLETE WITH DRIVERS AND PROVISIONING OF BRACKET MADE OUT OF GI TUBING LIGHT GRADE 32/40 MM BORE 1.5 MTR LENGTH, BENT TO SHAPE AS REQUIRED AT SITE, ALL AS DIRECTED
17
-
-
SUPPLY AND FIXING FACTORY MADE SHEET METAL ENCLOSURES DOUBLE DOOR TYPE MADE OUT OF 1.2MM THICK MS SHEET, CONCEALED IN WALL, DB, TPN 4 WAY ALONGWITH MCCB 4 POLE 40A, 16 KA AS INCOMER WITH 200 AMP RATED BUSBAR, 230 VOLTS DUST & VERMIN PROOF, COMPLETE ALL AS SPECIFIED
1
-
-
SUPPLY AND FIXING FACTORY MADE SHEET METAL ENCLOSURES DOUBLE DOOR TYPE MADE OUT OF 1.2 MM THICK MS SHEET CONCEALLED IN WALL, SPN WITH 200AMP RATED BUSBAR 12WAY 230V DUST AND VERMIN PROOF COMPLETE ALL AS SPECIFIED
2
-
-
SUPPLY AND FIXING FACTORY MADE SHEET METAL ENCLOSURES DOUBLE DOOR TYPE MADE OUT OF 1.2 MM THICK MS SHEET CONCEALLED IN WALL, SPN 4 WAY , 230V DUST AND VERMIN PROOF COMPLETE ALL AS SPECIFIED
10
-
-
SUPPLY AND FIXING MCB SPN 40 AMP 220V, ALL AS SPECIFIED
22
-
-
SUPPLY AND FIXING MCB SP 6 TO 32 AMP 220V, ALL AS SPECIFIED
84
-
-
SUPPLY AND FIXING SWITCH PIANO FLUSH, BUTTON TYPE 6 AMPS, 2 WAY, COMPLETE ALL AS SPECIFED AND AS DIRECTED
12
-
-
SUPPLY AND FIXING 4.0 MM DIA GI OR STEEL WIRE, AS EARTH CONTINUITY CONDUCTOR OR MAIN EARTHING LEAD FIXED TO WALL / POLE OR BURIED IN GROUND OR DRAWN IN CONDUIT/PIPE OR ANY OTHER INDICATED SITUATION FOR LOOP EARTHING ETC ALL AS SPECIFIED AND DIRECTED
130
-
-
Supply installation and testing air cooled split type air conditioner, electric driven single phase, AC, 240 v, 50 Hz, capacity 3 TR, 5 star rating CFC free indoor/outdoor components with cordless remote control unit and with inbuilt air ioniser and plasma filter for better indoor air quality including suitable size of copper pipe and provn of ms brackets complete all as specified (briefing hall)
17
-
-
Supply installation and testing air cooled split type air conditioner, electric driven single phase, AC, 240 v, 50 Hz, capacity 1.5 TR, 5 star rating cfc free indoor/outdoor components with cordless remote control unit and with inbuilt air ioniser and plasma filter for better indoor air quality including suitable size of copper pipe and provn of ms brackets complete all as specified (existing hanger annexe)
17
-
-
Supply and fixing voltage stabilizer with overload protection, bypass arrangement and high voltage cut off system, single phase, naturally air cooled, indoor type and designed for input variation between 140 to 270 V and output 230 volts with plus or minus 2.5% accuracy and of capacity 5 KVa, all as specified and directed.
17
-
-
Supply and fixing voltage stabilizer with overload protection, bypass arrangement and high voltage cut off system, single phase, naturally air cooled, indoor type and designed for input variation between 140 to 270 V and output 230 volts with plus or minus 2.5% accuracy and of capacity 3 KVa, all as specified and directed.
6
-
-
Supply and fixing metal socket enclosure with a two pin and earth plug and socket with double pole MCB 20 amp rated.
23
-
-
M&L for Machine pressed precast concrete grass paver block any shape and size of 60mm thick with grey cement & pigment, M35 grade complete all as specified and directed.
1050
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%