Summary

Construction Of Technical Accommodation For Gladiators At Af Station Pathankot

Are you looking for Materials and Services for this tender?
We will help YOU to find the right partner for your needs for FREE!
BOQ Items
ItemQuantityUnitsRateAmount
... more
BUILDING PART:-
-- -
... more
SCHEDULE 'A' PART-I (SECTION-I) Design, supply, fabrication and erection of pre-engineered building (PEB) steel structure for portion mark " PEB STRUCTURE HANGAR" including all civil works in RCC foundations duly designed, steel sliding motorised Hangar door system to be provided on front and rear of the hangar, including the work listed in Sch 'A' notes and shown on drawings, design of PEB structure along with design for structural system for hangar door as per parameters for hangars and door as specified from approved firms as listed and vetting of design, drawing from IIT before acceptance of tender, complete all as specified and shown on drawings with the following:- (Cont to 1.02 to 1.03)
1Each Job- -
... more
Note :- Rates quoted by the contractor shall also deem to be included the cost of the following :- (i) Design of PEB structure Hangar portion along with structural system for hangar door from PEB approved firm/vender as listed in particular specifications along with vetting of design/drawing from IIT . (ii) Design of RCC foundations. (iii) Arch drgs provided by the department will form part of contract however structural drawings for hangar provided by contractor, which will be vetted by IIT. (iv) The structural steel members shall be designed as specified here in before and in particular specifications.
-- -
... more
(v) The steel sliding motorised Hangar door system for Rear & front doors for the hangar, shall be designed as specified in particular specifications. (vi) The design for structural system for the Hangar door will also be vetted by the same organisation vetting the steel Hangar Design.
-- -
... more
Total amount of Sch 'A' Part-I (Section-II) (Bldg work)
1Lump sum- -
... more
Total amount of Sch 'A' part-II (Internal water supply)
1Lump sum- -
... more
Total amount of Sch 'A' part-III ( Plumbing Work)
1Lump sum- -
... more
Total amount of Sch 'A' part-IV (Section-I) (Internal Electrification Works)
1Lump sum- -
... more
Total amount of Sch 'A' part-IV (Section-II) (Internal Electrification Works)Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
-- -
... more
Integrated batten T5 of 1x20Watt, 4 FT, white, indoor decorative PVC extruded T5 LED batten integrated typet, complete all as specified and directed by Engr-in-Charge.
198Each- -
... more
Integrated batten T5 of 2x20Watt, 4 FT, white, indoor decorative PVC extruded T5 LED batten integrated typet, complete all as specified and directed by Engr-in-Charge.
112Each- -
... more
Lamp holder insulated body with back plate (ISI marked) for batten fittings including LED lamp of 10 Watt, complete all as specified and directed by Engr-in-Charge.
4Each- -
... more
Surface mounted LED luminare for mirror lighting 10 watt Complete with lamp including connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.50 sqmm, complete all as specified and directed by Engr-in-Charge.
4Each- -
... more
LED Street light fitting 40 Watt , IP66 power coated pressure die cast aluminium compact high power LED street light with heat resistant toughened glass including street light bracket made out of 40mm dia GI pipe light grade 1.2 mtr long ,bent to shape, with all necessary fittings i.e nuts,bolts, clamps made out of flat iron 50X6mm -02 nos.complete all as specified and as directed by Engr-n-Charge.
29Each- -
... more
Suspended type decorative non integral high bay downlights luminaries 230 V 300 Watt LED, totally enclosed type with separate control gear box, closed version with anodised aluminium wide beam reflector comprises of Ni housing, reflector, toughned glass cover including fixing arrangement complete all as specified and directed by Engineer-in-Charge.
140Each- -
... more
Ceiling fan 5 star rated (as per BEE recommendation) 1200mm sweep single phase 230 volts 50 Hz AC supply totally enclosed heavy duty motor with die cast aluminium rotor complete with down rod, regulator including hanging of fan, connecting electrically using 3 core 0.75sq mm PVC insulated flexible copper conductor cable over all sheathed all as required at site or directed by engr-in-Charge
65Each- -
... more
Heavy duty exhaust fan (as per BEE recommendation) 300mm sweep single phase 230 volts 50 Hz AC supply totally enclosed heavy duty motor with die cast alumn rotor mounted on two ball bearings complete louvers including cutting chases for fixing fan, connecting electrically using 3 core 0.75sq mm PVC insulated flexible copper conductor cable over all sheathed all as required at site or directed by Engr-in-Charge
9Each- -
... more
Distribution board, triple pole & neutral 415 volts iron clad, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar and netural link confirming complete with one MCCB 4 pole 415 volts 250 amps rating with rupturing cap 36 KA of the same make as of distribution board and including cuttting chases to wall for fixing DB and making good the distrubed wall surface complete all as required at site for AC in annex directed by Engineer-in-Charge.
3Each- -
... more
Bus bar chambers fabricated sheet steel (CRCA) of 1.6mm thickness and epoxy powder coated with superior & lasting finish, sections made of ETP grade copper & dull tin plated and the bus bar supports made of DMC (Dough moulding compound) of size 600X 450 mm including 4 Nos 200 amp rated copper bus bar conform to IEC-60439/IS-8623 and IEC-60529/IS-2147 mounted on porselain insulators complete fixed flush wall and making good the disturbed wall surfaces all as required at site or as directed.
1Each- -
... more
MCB single pole 240 Volts 6 to 32 amps with rupturing capacity 10 KA, "B" Curve type, complete all as specified.
139Each- -
... more
MCB single pole 240 Volts 40 to 63 amps with rupturing capacity 10 KA, "B" Curve type, complete all as specified.
27Each- -
... more
MCB single pole and neutral 240 Volts 35 to 63amps with rupturing capacity 10 KA "B" curve type, complete all as specified.
24Each- -
... more
Rigid steel conduit stove enamelled black 40 mm dia welded, exclusive of junction and terminal boxes but inclusive of all fittings such as tees, bends, albows, reducers, bell mouth tube ends and all fixing accessories such as, lock nuts saddles pipe hook etc complete all as specified and directed by Engineer-in Charge.
100Rm- -
... more
Total amount of Sch 'A' part-V (ROAD, PATH AND CULVERT WORKS)
1Lump sum- -
... more
Total amount of Sch 'A' part-VI (RCC Drain and Cable works)
1Lump sum- -
... more
Total amount of Sch 'A' part-VII (Sewage Disposal Works)
1Lump sum- -
... more
Total amount of Sch 'A' part-VIII (Lightning Protection Work)
1Lump sum- -
... more
Total amount of Sch 'A' part-IX (Section-I) (External Water Supply Works)
1Lump sum- -
... more
Total amount of Sch 'A' part-IX (Section-II) (External Water Supply Works)Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
-- -
... more
Sluice valve, flanged of class 1.0 PN of size 80mm dia including nuts, bolts and rubber washer complete all as specified and directed by Engr in charge.
2Each- -
... more
Cutting existing steel tubing for alterations or additions, Screwing existing steel tubing for alterations or additions screw on pipe to form connector done in position without taking down existing for 80 mm bore GI Pipe complete all as specified and directed
1Each- -
... more
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure, complete all as specified.
30Rm- -
... more
Material and labour for construction of valve pit including necessary excavation and earth work as required including necessary PCC work, brick work, plastering etc all as specified including fixing of MS sheet 6 mm thick cover and angle iron frame with locking arrangement including two coats of red oxide arrangement including two coats of red oxide primer internal size of pit 600X600X600mm, complete all as specified and directed by Engr in charge.
2Each Job- -
... more
Total amount of Sch 'A' part-X (Section-I) (Refregeration and Air Conditioning Works)
1Lump sum- -
... more
Total amount of Sch 'A' part-X (Section-II) (Refregeration and Air Conditioning Works)Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
-- -
... more
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled wall mounted, copper wound with digital display indoor type for AC & designed for input variation between 140 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 3 % and of capacity 5 KVA complete all as specified and directed by Engr-In-Charge. Make: Volina/Bluebird/Microtek
31Each- -
... more
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled wall mounted, copper wound with digital display indoor type for AC & designed for input variation between 140 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 3 % and of capacity 4 KVA complete all as specified and directed by Engr-In-Charge. Make: Volina/Bluebird/Microtek
28Each- -
... more
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled wall mounted, copper wound with digital display indoor type for AC & designed for input variation between 140 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 3 % and of capacity 2 KVA complete all as specified and directed by Engr-In-Charge. Make: Volina/Bluebird/Microtek
2Each- -
... more
Total amount of Sch 'A' part-XI (Section-I) (EXTERNAL ELECTRIFICATION WORKS)
1Lump sum- -
... more
Total amount of Sch 'A' part-XI (Section-II) (EXTERNAL ELECTRIFICATION WORKS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
-- -
... more
Supplying, installing, testing & commissioning of factory assembled silent Diesel Engine driven generating set 1500RPM of capacity 500 KVA, 3 phase, 4 wire,415 volt, 0.8 PF (MSL complete with control panel including integrated powder coated acpistoc enclosure as per CPCB regulations and duly certified by agencies/labs designated by CPCB for noise and sound pollution level, etc floor mounted including PCC foundation as per manufacturer's instructions complete all as specified and directed and comprising of the following :- (A) DIESEL ENGINE required capacity for driving 500 KVA alternator multi cylinder, vertical type, 4 stroke, water cooled, electric start conforming to IS : 10001/10002/BS-5514 for continuous running capable of taking 10% overload for one hour in 12 hours complete and comprising of the following :- (i) Radiator cooling (ii) Radiator fan with guard (iii) Flywheel with starter ring (iv) Air cleaner oil bath type (v) Vacuum indicator (vi) Electronic governor class 1A (vii) Exhaust silencer (viii) Fuel filter & fuel hoses (ix) Fuel injection pump (FIP) (x) Fan & water pump assembly (xi) Lub oil filter & Pump (xii) Oil filter (xiii) Exhaust gas driven turbo charger (xiv) Lub oil cooler (xv) Engine maintenance manual with spare parts list (xvi) Suitably designed acoustic enclosure as per CPCB regulations. (xvii) Engine safety shut down system against low lub oil pressure and high water pressure (Cont to 15.02 to 15.04)
1Each - -
... more
(xviii) Electric starting system with battery charging alternator and axial type starter motor including adequate number of high capacity maintenance free lead acid battery 12 volts 180 AH DC or as per manufacturers requirement including interconnecting cables/leads with terminals complete with starting/stopping switch, volt meter etc - 01 Set. (B) ENGINE INSTRUMENT PANEL digital type indicating the following (i) Starting switch on/off (ii) Water temp guage (iii) Hour meter cum RPM indicator (iv) Lub oil pressure (v) Lub oil temperature (vi) Battery charging meter (vii) Safety alarm against high water temp and lub oil pressure (c) ALTERNATOR Shall be self excited, self regulated, brush less for 500 KVA continuous operation at the speed of 1500 RPM at 415 volts, 50Hz , three phase four wire system with advance electric voltage regulator to ensure high voltage accuracy with + 1% with class H insulation and SPDP enclosure directly coupled with engine through flexible coupling and confirming IS- 13364 complete- 1 No. (D) Common fabricated base frame for engine & alternator made from structural channel, jerk proof PCC 1:2:4 type B1 foundation including adequate number of .suitable anti-vibration pads all as per the recommendation of the manufacture- 01 No (NOTE:- Cost of suitable size of PCC foundation is deemed to be included in the unit rate quoted by the contractor.
-- -
... more
(E) Fuel tank fabricated out of 14 SWG MS sheet of capacity not less than 8 hrs continuous operation, inside canopy, with fuel level guage, drain plug, locking arrengements, etc with & including GI pipe connections duly laid as per engineering practice complete. (F) AMF CONTROL PANEL Supply, fabrication, fixing commissioning and testing, factory made, floor mounted, cubical automatic mains failure panel suitable for 500 KVA DG set, fabricated using 14 guage thick CRCA sheet, powder coated painting, suitable rated bus bar, internal wiring with control fuse, provn of connecting incoming & outgoing leads/bus bas as approved with and including the following accessories as under:- (i) Master switch for auto/manual/reset/off- 01 No (ii) Ammeter digital type 96x96 mm to read 0 - 400 amps with CT's 1 set of 3, aux supply 230 volts, AC, accuracy class 1.0 (iii) Voltmeter digital type,96 x 96 mm to read 0 - 500 volts aux supply 230 volts, AC, accuracy class 1.0 (iv) Digital frequency meter -01 No. aux supply 230 volts, AC (v) Push button start, stop/ reset - 01 No (vi) Set of lamp for indicating load on , low pressure, high cylinder temperature, load on mains, set fails to start, low oil pressure
-- -
... more
(vii) Battery charger, connected to load side to charge battery from mains comprising of :- (a) Transformer of adequate rating. (b) Rectifiers (c) DC Ampere and volt meter (d) Charger rate selector for trickle or high charging (e) Indicating lamp for battery charging (viii) Fault accept/reset push button (ix) Set of relays and contactor with MCCB, 4 pole, 630 Amps,415 volt, 50 KA for automatic start & automatically shut down of DG set of suitable rating & capacity - 02 Nos (x) By pass arrangement by prooving change over switch of 630 Amps 4 Pole in separate panel box to be installed with AMF -02 Nos Note : AMF Panel shall be installed out side the coustic enclosure.
-- -
... more
S&F installation testing and commisining of LT electric panel board totally enclosed (Factory, Fabricated), Outdoor type double door type powder coated inside & outside made out of CRCA sheet not less than 3.15 mm thick with front & Back opening having locking arrangement spray painting internally/externally, including internal wiring with suitable size of copper strip bus bar chamber 3 phase and four wire type system 415 volts 50 Hz consisting of copper bus bar of capacity 1600 Amps confirming to IS:13947(Part-I & Part-III) of 1993 and consisting of the following:- (a) ACB FP 1250 Amp 50 KA -1 No (Incomming) (b) MCCB FP 315 Amps, 36 kA - 01 No (for APFC) (c) MCCB FP 200 Amps, 36 kA - 01 No (for Hangar) (d) MCCB FP 250 Amps, 36 kA - 03 Nos (for GF, FF & Spare) (e) Voltmeter 0-500V with selector switch-1 No (f) Indicator lamp with Holder 3 No-One set (g) Ammeter with CT ratio 1600/5 Amps with selector switch- 1 No (h) MCB 4 Pole -20 A 10 KA ( Street light) (j) Timer Switch - 01 No.
1Each - -
... more
S&F installation testing and commisining of LT electric panel board totally enclosed (Factory, Fabricated), Outdoor type double door type powder coated inside & outside made out of CRCA sheet not less than 3.15 mm thick with front opening having locking arrangement spray painting internally/externally, including internal wiring with suitable size of copper strip bus bar chamber 3 phase and four wire type system 415 volts 50 Hz consisting of copper bus bar of capacity 1600 Amps confirming to IS:13947(Part-I & Part-III) of 1993 and consisting of the following:- (a) ACB FP 1600 Amp 50 KA -1 No (Incomming) (b) MCCB FP 500 Amps, 36kA - 01 No (for APFC) (c) Voltmeter 0-500V with selector switch-1 No (d) Indicator lamp with Holder 3 No-One set (e) Ammeter with CT ratio 1600/5 Amps with selector switch- 1 No (f) ACB FP 1200 Amp 50 KA -1 No (Eqpt load)
1Each - -
... more
S&F installation testing and commisining of LT electric panel board totally enclosed (Factory, Fabricated), Indoor type double door type powder coated inside & outside made out of CRCA sheet not less than 2.00 mm thick with front & Back opening having locking arrangement spray painting internally/externally, including internal wiring with suitable size of copper strip bus bar chamber 3 phase and four wire type system 415 volts 50 Hz consisting of copper bus bar of capacity 1600 Amps confirming to IS:13947(Part-I & Part-III) of 1993 and consisting of the following:- (a) ACB FP 1600 Amp 50KA-1 No (Eqpt Load) (b) Voltmeter 0-500V with selector switch-1 No (c) Indicator lamp with Holder 3 No-One set (d) Ammeter with CT ratio 1600/5 Amps with selector switch- 1 No
1Each- -
... more
S&F in replacement of street light fitting LED type 72 Watt or higher side with pressure die casted aluminium housing with flat glass optical cover with lens to ensure uniform distribution with minimum 100 lumen/watt efficacy, IP 66 protection including sluge protection 5ka, LED Driver and housing of same make as of fitting as per BIS standards including connecting terminals, mounting clamp, mounting bracket if required and all other accessories reqd for fixing and making fitting operational complete as directed by Engineer-in-Charge. Make: Philips/CGL/Bajaj/Havells
39Each- -
... more
Supply and fixing in replacement junction box outdoor type of size not less than 0.01 cum made of steel sheet 1.6 mm thick painted with two coat of synthetic enamel paint over a coat of red oxide primer having aluminium bus bar 4 Nos of capacity 100 amps mounted on porcelain/PVC insulator suitable for connection of minimum 2 nos LT cables of size 25/35 sqmm 3.5 core including clamps, nuts and bolts etc, 1 No MCB SP 6 Amps complete all as specified and directed by Engr-In-Charge.
23Each- -
... more
Supply and fixing Aviation obstruction lights LED type with minimum 300 LEDs in aluminum housing and polycarbonate enclosure complete all as specified and directed.
2Each- -
... more
M&L for boring of holes under road, pavement, hard standing by trenchless technology or by mechanical means including making good to existing disturbed surfaces matching with existing complete all as specified and directed by Engr-In-Charge.
30Rm- -
... more
M & L for plateform for installation of transformer of mentioned size (750 KVA & 1000 KVA) and manufacture reccomandation, with brick construction in step on one side XPM jalli and fixed on angle iron post and gate openable type with locking arrangement earthwork in any type of soil incl plastering to bricks masonary work and painting to steel surface with two coat of synthetic enamel paint over a coat of primer and two coat of colour washing over a coat of white wash on plaster surface incl MS stand with locking arrangement for mounting transformer complete all as specified and directed. Note :- Confirming to TD Drg No. 1129 of Chief Engineer Udhampur Zone (Army)
2Each Job- -
... more
Total amount of Sch 'A' part-XII (Section-I) (Fire Fighting Works)
1Lump sum- -
... more
Total amount of Sch 'A' part-XII (Section-II) (Fire Fighting Works) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
-- -
... more
Supply installation testing and commissioning of repeater panel complying with BS EN 54 suitable for wall mounting confirming to IS-2189 fabricated out of 16 guage CRCA sheet incorporating audio visual indication including dry type maintenance free battery of suitable capicity and battery charger complete all as specified and directed by Engr-In-Charge. Make: Honeywell/Agni or equivalent as approved
4Each - -
... more
Supply and fixing mannual operated monitor of long range suitable for pressure 7 bar, spray angle 120 degree, and vertical rotation 30 to 80 degree suitable for inlet connection with 100mm CI Pipe complete all as specified and directed by Engr-In-Charge.
2Each - -
... more
Total amount of Sch 'A' part-XIII (LAN Conduit Works)
1Lump sum- -
... more
Total amount of Sch 'A' part-XIV (EOT Crane Works) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
-- -
... more
Design, Supply, Installation, testing and commissioning of 10 Ton capacity EOT Crane double girder, electrically operated through pendant push button station floor operated type having hoisting height of 8 Mtrs approx, trolley with frame, crab buffers, gears with gear boxes shafts, rope drum, rope sheaves, wire rope, wheels, lifting hook, plate form on one side of the crane brackets, motors, limit switches, control panel pendant push button station, micro speed arrangements, wiring etc as per IS-3177, 807. All as specified below :- (a) Capacity 10.0 Tons (b) Cross span - 62 Metres (c) Long Span - 90 Metres (d) Hoist Lift 8 metres (e) Hoisting speed - 3 mpm and creep/micro speed 0.6 mpm (f) Hoisting motor of suitable HP as per design calculation submitted by OEM/Contractor (g) Cross travel speed - 10 mpm and creep/Micro speed of 2mpm (h) Cross travel motor of suitable HP as per design calculation submitted by OEM/Contractor (j) Long travel speed - 15 mpm and creep/Micro speed of 3 mpm (k) Long Travel motor, 1/2 Nos of suitable HP AS PER Design calculation submitted by contractor. (l) Operation pendant Push button from floor (m) Class of duty - II (Indoor ) (Cont to 19.02)
1Each- -
... more
Mechanical (a) Steel : Stell should be conforming to IS-2062 or equivalent is used in the manufacturing of the crane. (b) Material and workmanship : All material used in crane shold be selected from quality material. Adequate factor of safety should be used in the design of all parts subjected to stresses and shocks. (c) Gear Boxes : As per manufactures specifications. (d) Bearing : All moving part of the cranes should be supported on antifriction type ball / roller bearing (e) Coupling : Flexible/Universal/Geared/Rigid coupling should be provided between hoisting and drum. (f) Wheels : The wheel of the L.T. motion shall be forged/Cost steeel confirming to IS-2707. grade-II Single flanged taper tread type fitted with antifriction bearing for the ease of the maintenance. (g) Bridge Girder : The bridge girder should be ISMB type which is designed to sustain all stresses arising due to vertical and lateral forces with impact to which they are subjected. (hl) End Stoppers : Steel ended stopper should be provided on both the side of the bridge girder to stop the motion of the trolley. (j) End carriage : End carriages should be ISMC type from rolled steel section with adequate diaphragms and stiffners to give rigid constuction. Rubber buffers should be provided on either side of the End carriages. (k) Painting : The structural part of the cranes should be thoroughly cleaned and should be applied one coat of the red oxide and two coats of flame proof enamel paint before installing.
-- -
... more
Supply and fix electrically operated EOT, portable I-Beam trolley gantry crane without cabin of capacity 0.4 Ton,Cross Travel - 03 Mtrs, lifting height 03 mtr from FFL, with duty class II as per IS-3177, 807, including pendant push button for indoor use without any auxiliary hoist, having speed of CT - 15 MPM and creep/Micro speed of 3.0 mpm, Hoist speed 3 mpm and creep/Micro speed 0.6 MPM complete all as specified and directed.
2Each- -
... more
Total amount of Sch 'A' part-XV (PQC Works) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
-- -
... more
Rolling and consolidation formation surfaces in cutting at OMC to achieve 98 percent of maximum of dry density (modified PROCTOR density) and to achive K-value of 5.30Kg/SqCm/Cm with 8 to 12 Tonne power roller including filling in soft spots, depression etc., which occur during rolling (for portion coming in cutting/original ground only) to required level and gradient including watering before and during rolling, complete all as specified and directed.
350X Sqm- -
... more
200mm thick Ganular sub Base(GSB) of grading II as per MORTH specification, surface formed, roller consolidated to required gradient and chamber, using earth compactor of 8 tonne to 15 tonne capacity or compaction at OMC to achieve the min 98 % density of MOD determined using modified proctor density determination method as per IS code to achieve min CBR 30 %, laid in layers of consolidated thickness all as specified and directed.
350X Sqm- -
... more
150mm consolidated thick Wet mix Macadam (WMM) with coarse aggregate of specified grade as per MORTH, spread, roller and consolidation to required gradient and camber using mechanical paver/grader and tandom vibratory roller/earth compactor of capacity 8 tonne to 15 tonne or compaction at OMC to achieve the min 98 % denisity of MOD determined using modified proctor density determination method as per IS code laid in layers of consolidation thickness all as specified and director.
350X Sqm- -
... more
150mm thick DLC (Dry lean concrete) with 7 days compressive strength of 10 N/sqmm with min cement content of 240 kg/cum or as per design mix whichever is more using grading as per MORTH specificion, spread rolled and consolidated to required camber and gradient using necessary mechanical sensor paver and tendom vibratory roller of capacity exceeding 8 ton and n exc 12 ton capacity complete all as specified and director.
525Cum- -
... more
350 mm thick pavement quality concrete in pavement of flexural strength 45 kg/sqcm ( lower control limit) in field using min 400 kg of cement per cum with 20mm nominal size of aggregate and super plastisizer if required as per design mix ( as per IRC Vth revision ) mixed with and including triangular /non curricular synthetic fibre reinforcement @ 0.25% by weight of cement with 12mm length, specified gravity 1:3 to 1:4 (other specification as per IRC/MORTH) spread and compacted by using slip form paver and all as specified and including necessary by using form work, bull noising, rounding of edges, finishing by mechnical brooming/belting, curing etc., complete all as specified and as director
525Cum- -
... more
Forming construction joint 25mn deep and 10 mm wide (using diamond cutter ) providing polythene backup rod 12mm dia sealed with polyurethane sealant ( min depth of sealant 12mm ) complying with BS 5212, BS 4254 and EN 41875-2003 priming the sides min MAF ±30% with ten years performance guarantee and applying masking tape on edge of joint prevent accident spiliage of sealant on top surface to give net finish to sealant and removing the masking tape after sealant is applied by mechanical means all as shown on drawings specified and as director.
350X Rm- -
... more
Forming dummy joint 1/3depth of slab i.e 50 mm depth and 8mm wide (using diamond cutter ) providing backup rod 10mm dia and sealed with polyurethane sealant (min depth of sealant 12mm ) complying with BS 5212, BS 4254 and EN 41875-2003 priming the sides min MAF ±30% with ten years performance guarantee and applying masking tape on edge of joint prevent accidental spilage of sealant on top surface to give neat finish to sealant and removing the masking tape after sealant is applied by mechanical means all as shown on drawings specified and as director.
100X Rm- -
... more
forming 25 mm wide expension joint filled with compressible synthetic filler board for complete depth of joint 150mm i.e the thickness of slab, provision of closed cell backup rod 30mm dia , filled with polyurethane sealant (mm depth of sealant above back up rod shall be of 15mm ) complying with BS 5212, BS 4254 and EN 41875-2003 priming the sides min MAF ±30% with ten years performance guarantee and applying masking tape on edge of joint prevent accidential spiliage of sealant on top surface to give neat finish to sealant and removing the masking tape after sealant is applied by mechanical means all as shown on drawings specified and as director.
15X Rm- -
... more
Total amount of Sch 'A' part-XVI (Working Station works)
1Lump sum- -
... more
Total amount of Sch 'A' part-XVII (Sec-I) (RO Plant works)
1Lump sum- -
... more
Total amount of Sch 'A' part-XVII (Section-II) (RO Plant works) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
-- -
... more
Supply and fix Reverse Osmosis Plant double purification by RO+UF with TDS controller of output capacity of 25 Litres per hour complete all as specified and directed.
2Each - -
... more
Total amount of Sch 'A' part-XVIII (False Ceiling Works) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
-- -
... more
Anodised aluminum snap grid of size 605 mm x 605mm frame work for false ceiling all as specified as per drawings and specifiion of manufacturers and as directed by Engineer-in-charge
1985Sqm- -
... more
False seiling eco-friendly light weight calcium silicate board densified regular edged board/tile of size 600mm x 600mm and minimum 12 mm thick with overall density 350kg/cum at the egdes in true horizontal level suspended on interlocking metal grid laying as per specification of manufacturer and as directed by Engineer-in-charge.
1985Sqm- -
... more
Total amount of Sch 'A' part-XIX (Signage and Making Board Works) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
-- -
... more
Double legged informatory sign board of any following size made out of 2mm thick aluminum sheet confirming to IS 736 to be covered with Hi intensity grade retro reflective film of shade as approved including boarder of 20mm thick as per IRC standard and letter of any type and colour ( size and colour as approved) to be fixed to sheet with suitable adhensive aluminum sheet fixed to structural street frame work made of MS square pipe 32mm dia heay duty fixed with nuts bolts/revets ensuring sagety against removal of plates MS tabular pipe frame fixed to two vertical posts made of 50mm size MS square pipe heavy duty (height from ground level to bottom of sheet is 2m to 4m as required as per site constraints) pipe should be cover with hi-intergrity graderetro reflective sheeting and al least 600mm in ground level for grip to sagety against over turning with cross of flat iron (FI 40 x 5) of 230mm long complete in all respect including two coats of synthetic enamble point over a coat of red oxide primer and including excavation and earth work in any type of soil and ground in PCC 1:3:6 type C 1 (using 20 mm grade aggregated complete all as specified and director by Engineer-in-charge
-- -
... more
Information sign of size 1044mm X 800mm and leg legth 600mm, complete all as specified and directed by Engr in charge..
10Each- -
... more
Information sign of size 2836mm X 800mm and leg legth 600mm, complete all as specified and directed by Engr in charge..
2Each- -
... more
Information sign of size 2000mm X 800mm and leg legth 600mm, complete all as specified and directed by Engr in charge..
2Each- -
... more
Total amount of Sch 'A' part-XX (Site Clearance and earth works)
1Lump sum- -

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.