Military Engineer Services Tender
... More
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 87,600Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_672068_2Tender No
CA NO CWE SGNR T-23 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
M&L rough cast over rendering of 10 mm thick on fair face of brick or concrete surface as in CM 1:4 all as specified and directed by Engr-In-Charge.(The rough cast mixture shall consist of crushed stone or fine gravel aggregate, coarse sand & cement in the ratio of 1:1:1 over rendering coat.)
200
-
-
... More
M&L for 5mm thick plaster on ceiling in cement mortar (1:3) finished even and smooth without using extra cement complete all as specified and directed by Engr-In-Charge.
150
-
-
... More
Taking down old deteriorated concrete /plaster of old surfaces of facia,parapet,slab edges,projection bottom etc & applying 15mm thick rendering in cement mortar 1:3, finishing surfaces even and smooth without using extra cement including two coat of exterior acrylic emulsion paint with necessary scaffolding,doubing coat complete all as specified and directed.
Note:-Work is to executed in buildings of height upto 15 metres and Quoted rate of the item is deemed to included the same.
50
-
-
... More
Demolition/Dismantling of brick work or stone/boulder masonary built in any cement mortor including all quoins,arches,pillars etc complete all as specified & directed by Engr-In-Charge.
12
-
-
... More
M & L for brick work with old size fly ash bricks, straight or covered or plan exc 6m mean radius built in CM 1:6 complete all as specified and directed by Engineer in Charge.
12
-
-
... More
M&L for Preparation of newly plastered surfaces of walls etc., and applying two coats of cement base paint complete all as specified & directed by Engr-In-Charge.
1200
-
-
... More
M&L for preparation of Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified & directed by Engr-In-Charge.
200
-
-
... More
M&L Preparation of new plastered surfaces of walls & applying two coats of oil bound distemper over a coat of chalk whitening complete all as specified & directed by Engr-In-Charge.
637.5
-
-
... More
M&L for Preparation of newly plastered surfaces of walls etc., and applying two coats of white wash complete all as specified & directed by Engr-In-Charge.
212.5
-
-
... More
M&L for Preparation of new plastered surfaces and applying two coats of white wash on ceiling as specified & directed by Engr-In-Charge.
150
-
-
... More
M&L Preparation of old srufaces of wall including brooming down or steel wire brushing, scrapping down smoke soot, mould, moss and efflorescent salts and trading oil and greasy spots and applying one coat of oil bound distemper after filling of putty in minor cracks present (if any) complete all as specified and directed by Engr-In-Charge.
600
-
-
... More
M&L Preparation of old srufaces of wall including brooming down or steel wire brushing, scrapping down smoke soot, mould, moss and efflorescent salts and trading oil and greasy spots and applying one coat of Cement base paint complete all as specified and directed by Engr-In-Charge.
800
-
-
... More
M&L Preparation of old srufaces of wall including brooming down or steel wire brushing, scrapping down smoke soot, mould, moss and efflorescent salts and trading oil and greasy spots and applying two coat of white wash complete all as specified and directed by Engr-In-Charge.
400
-
-
... More
M&L for preparation of old decorated surfaces of wall by brooming down and scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coat of distemper oil emultion white/tinted over a wall care putty finished surface complete all as specified.
700
-
-
... More
M&L for complete removal of existing old decorated surfaces of wall by brooming down and scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coat of acrylic emulsion paint complete all as specified.
Note :- Curing of surface will be carried out as per Para 15.15.3 of SSR Part-I
1100
-
-
... More
Demolition of unreinforced cement concrete in ground floor, plinth protection, paving not exceeding 15 cm thick (below or above ground level) complete all as specified & directed by Engr-In-Charge.
33.75
-
-
... More
M&L for 75 mm thick cement concrete 1:3:6, type C-2, (using 40mm graded crushed stone aggregate) as in plinth protection/path, finishing surfaces even and fair complete all as specified and directed .
450
-
-
... More
M&L for 100 mm thick cement concrete 1:2:4 type B-1, (using 20mm graded crushed stone aggregate) as in hard standing, flooring, finishing surfaces even and fair complete all as specified and directed .
200
-
-
... More
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by engr-in-charge.
750
-
-
... More
M & L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick,and pointed in white or coloured cement to match & including 15 mm thick screed in cement mortar (1:6) and pointed in white cement with pigment to match the colour of tiles complete all as specified and directed by engr-in-charge.
200
-
-
... More
S&F Glazed ceramic coloured tiles with highlighter in vertical surface 600x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 15 mm thick rendering in CM 1:4 on other than fair face of brick work. Note : Highlighter shall be provided as directed by Engr-in-Charge.
400
-
-
... More
M&L for Endura floor / parking Vitrified tiles 10 mm thick square /rectangular polished area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors etc .set and jointed in neat cement slurry over and including 15 mm thick screed bed in CM (1:6) and poined in white or colour cement to match complete all as specified & directed by Engr-In-Charge.
150
-
-
... More
M&L for ceramic vitrified tiles 8 to 9mm thick square/ rectangular polished area of each tiles exc 0.42 Sqm but n.exc 1.00 Sqm in floors etc set and jointed in neat cement slurry over including 15mm thick screed bed CM 1:6 and pointed in white or colour cement to match complete all as specified & directed by Engr-In-Charge.
195
-
-
... More
Dismantling of Stone slabs of any description or thickness in floors, plateform, apron etc laid bedded and pointed in any mortar including removing rubbish material from building and thrown in low lying empty area at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge.
24.7
-
-
... More
M&L 20 to 25mm thick Machine cut kota stone slab as in flooring over and including 20mm thick screed bed in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified.
200
-
-
... More
M&L Kota stone slab 20-25mm thick as in riser of steps, skirting, dado and pillar over and including 15 mm thick rendering 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete
20
-
-
... More
M & L for Marble work 18 to 20mm thick of any shade (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade over and including 10 mm rendering in CM 1:6 complete all as specified and directed by Engr-In-Charge.
15
-
-
... More
M&L Granite of any type machine cut 20mm thick, set and jointed in cement slurry over & including screed of 15 mm thick in cement mortar (1:6) and pointed in cement mixed with pigment to match the shade of slab including rubbing, cutting and mirror type polishing & with adhesive complete all as specified & directed by Engr-In-Charge.
12
-
-
... More
Taking down the steel rolling shutter push type and n.exc 15 Sqm area of clear opening each including hood cover and cleaning the sides of shutter suspension and guide channel and greasing all the moving parts of rolling shutter shaft and replacement of bolts and nuts as required for smooth functioning of shutters, incl necessary welding wherever required as directed giving proper tension to the spring and refixing the shutter and gear box including hood cover in same opening after repair work complete all as specified and directed by Engr-in-charge.
10
-
-
... More
All as per Ser item No 32.00 above but gear operated rolling shutter exc 15 Sqm but n-exc 30 sqm area including adjustment of gear worms assembly complete all as specifed and directed.
8
-
-
... More
S&F in repair mild steel lock plates/ handles made out of MS flat 35x5 complete all as specifed.
15
-
-
... More
S&F in repair mild steel helical wire spring (Confirming to IS 6248-1970) of gauge 1 of approved make for rolling shutter size upto 30 Sqm complete all as specifed.
6
-
-
... More
S & F in repairs MS gear assembly complete including connecting and fixing the gear box to wall with 4 Nos hexagonal bolts 10mm dia 10 cm long complete and grouting the bolt in cement mortar in 1:3 complete all as specifed.
2
-
-
... More
S & F in repair in MS hood cover made out of mild steel sheets 1.00mm thick including bending the steel sheets to required shape and fixing the sheet to the rolling shutters bracket plate including with plain 40 mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required complete all as specified and directed.
40
-
-
... More
S & F in repairs of roller ball bearing ISI marked for 40mm dia pipe shaft all as specified
4
-
-
... More
Supply only MS gear handles of approved make for gear operated rolling shutters complete all as specifed.
20
-
-
... More
S&F for Steel rolling shutters, gear operated type with bevel gear box and crank handle, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; errected in position as indicated, complete: push pull or manual type thickness of latch 1.25 mm complete all as specified and directed
22
-
-
... More
S&F in repairs interlocking lath section formed (confirming to IS 6248-1970) from rolled MS Strip for rolling shutter (of existing width ) 1.00 mm thick complete all as specified and directed.
15
-
-
... More
M & L for preparation of new steel surface of any description over 10 cm in width or girth and applying two coats of Synthetic enamel paint over one coat of red oxide primer complete all as specifed.
37
-
-
... More
M&L for preparation of old painted steel surface and applying two coats of synthetic enamel paint all as specified and directed
100
-
-
... More
Dismantling old AC/ CGI/ Polycarbonate (corrugated, semi corrugated etc) sheets in roof coverings upto 15m height of bldg including necessary steel double scaffolding complete all as specified and directed.
250
-
-
... More
S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, bend to curve where required and fixed with self tapping screws upto 15 m height of bldg complete all as specified and directed.
50
-
-
... More
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
200
-
-
... More
S&F hollow PVC wall lining interlocking type 7mm thick plain/ coloured/ wood grain fitted into the wall with PVC rawal plug and steel screws including fillets on joints as per manufacturers instruction etc complete all as specified and directed.
Note : If any minor wlectric fittings and fixtures distrubed there will be match and fixed as existing.
650
-
-
... More
M&L for providing and fixing stainless steel (Grade-304) railing made of hollow tubes, channels, plates etc including welding, grinding, buffing, polishing and making curvature (Where ever required) and fitting the same with necessary stainless steel nuts and bolts complte, including fixing thr railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc of prequired size inclding making groove/ drill with suitable fixing arrangement in RCC floor/ staricase/ brickwall complete all as specified and directed.
52
-
-
... More
S&F pre coated gypsum board upto 6mm thick as in ceiling fixed with screws as per manufacturer's instructions including anodised aluminium snap grid frame work for false ceiling of grid 605 x 605mm hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasterners 12.5mm dia 40mm long complete all as specified and directed. Note : Quoted rate of the item deemed to be included for taking down and refixing (as per existing) minor electric fittings and fixtures (if any) on the surface of ceiling.
100
-
-
... More
Taking down carefully copper /aluminium point wiring (light, fan, socket or power) complete incl fixture and fitting such as Switches, ceiling roses, pandents, regulators,sockets, light fitting etc removing materials to store for keeping in safe custody for taking credit(credit for above items shuold be made as per conditions separately) and making good distrubed surface of wall ,floors etc. complete all as specified and as directed.
100
-
-
... More
M&L for Point wiring complete with ISI marked 1.5 sqmm single core PVC insulated unsheathed cable 1100V grade FRLS with multistranded copper conductor drawn through concealed in wall/ceiling surface and its accessories including PVC rigid concealed conduit heavy duty suitable size with all accessories such as bend, reducers, MS hooks, MS junction boxes, 2mm thick galvanised steel pressed sunken terminal boxes of suitable sizes for mounting of switchs, sockets, fan regulator etc covered with 3 mm thick plastic laminated Hylem top cover sheet of required color fixed with brass screws and cup washers painting terminal boxes inside and outside with one coat red oxide primer including fixing and 1.5 sqmm copper conductor as earth continuity to connect common earth dolly completed for the following all as specified.
-
-
-
... More
One light point/Fan point/Exhaust Point /bell point controlled by one way switch.
50
-
-
... More
One three pin socket out let 5 Amps on the same board with other switches.
25
-
-
... More
One 3 pin, 5A switch socket outlet point on independent board.
15
-
-
... More
All as per Ser item No 51.00 above but with 2.5 sqmm cable for 1No 16 amps socket outlet point on independent board including 2.5 sqmm PVC insulated unsheathed cable multistranded with copper conductor green in colour as earth continuity conductor all as specified.
10
-
-
... More
Supply and fixing PVC lamp holder suitable for LED 5 to 20 watt bulb complete all as specified and directed.
10
-
-
... More
S&F in replacement of LED tube light fitting 20W (4 feet long), 230V, surface and wall mounted LED batten with polycarbonate housing and integrated electronic driver and including connections up with copper conductor wire with suitable size as per specification and directed by Engineer-in-Charge.
30
-
-
... More
S&F in replacement of LED tube light fitting 10W (2 feet long), 230V, surface and wall mounted LED batten with polycarbonate housing and integrated electronic driver and including connections up with copper conductor wire with suitable size as per specification and directed by Engineer-in-Charge.
5
-
-
... More
M&L in replacement ceiling rose surface type, 65mm x 50mm three terminals, 3 phase / PVC / polycarbonate isolated body complete all as specified.
80
-
-
... More
M&L for submain wiring with two single core PVC FRLS insulated copper conductor 10 Sqmm and same 10 Sqmm for continuous earth wire drawn in existing PVC conduit and including taking down old unserviceable wire any type and making good disturbed surfaces of walls as necessary complete all as specified and directed.
50
-
-
... More
M&L for submain wiring with two single core PVC FRLS insulated copper conductor 6 Sqmm and same 6 Sqmm for continuous earth wire drawn in existing PVC conduit and including taking down old unserviceable wire any type and making good disturbed surfaces of walls as necessary complete all as specified and directed.
50
-
-
... More
S&F Piano type switch single pole 1 way 15/16 amps 230 volt AC supply complete all as specified.
100
-
-
... More
S&F socket two in one 3/5 Pin 5 Amps 230 volt AC supply complete all as specified.
50
-
-
... More
S&F Piano type switch single pole 1 way 15/16 amps 230 volt AC supply complete all as specified.
40
-
-
... More
S&F socket two in one 6 Pin 15/16 Amps 230 volt AC supply complete all as specified.
25
-
-
... More
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning including taking down old MCB and making good to the distributed walls and surface area complete all as specified and directed.
30
-
-
... More
Supply and fixing 240V, 10KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 AMP, in the MCB DB Complete with connection testing and commissioning including taking down old MCB SP and making good to the distributed walls and surface area etc complete all as specified and directed.
10
-
-
... More
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN 40 to 63 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning including taking down old MCB SPN and making good to the distributed walls and surface area etc complete all as specified and directed.
10
-
-
... More
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB top and MCB 20 Amps, 240V, AC supply, including taking down unserviceable AC box all type as specified and directed.
10
-
-
... More
Supply and fixing in replacement ceiling fan regulator, stepped down electronic type single phase, AC supply, 230V, fixed on laminated sheet top cover and connecting up complete all as specified and directed.
10
-
-
... More
Supply and laying rigid non-metallic PVC conduit size 25mm exclusive of boxes (juction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddies pipe hooks etc with all fitting including taking down old unserviceable pipe any type complete all as specified and directed.
100
-
-
... More
S&F in replacement of hylam sheet suitable size with cutting slot for mounting of switches sockets, fan regulators, including nut, washer thimble etc with 3mm thick plastic laminated sheet cover any size and making good to the disturbed surfaces of walls, matching the colour with existing surface complete all as specified and directed.
3
-
-
... More
S&F in replacement of MS sunken box 1.6mm thick galvanised steel pressed sunken terminal boxes size 75mm x 75mm and 60mm deep, painted on both sides inside and outside with one coat of red oxide primer of suitable size for mounting of switches sockets, fan regulators etc with 3mm thick plastic laminated sheet cover size 75mm x 75mm etc making good to the disturbed surfaces of walls, maching the colour with existing surface complete all as specified and directed by Engineer-in-Charge.
10
-
-
... More
S&F in replacement of MS sunken box 1.6mm thick galvanised steel pressed sunken terminal boxes size 100mm x 100mm and 60mm deep, painted on both sides inside and outside with one coat of red oxide primer of suitable size for mounting of switches sockets, fan regulators etc with 3mm thick plastic laminated sheet cover size 100mm x 100mm etc making good to the disturbed surfaces of walls, maching the colour with existing surface complete all as specified and directed by Engineer-in-Charge.
10
-
-
... More
S&F in replacement of MS sunken box 1.6mm thick galvanised steel pressed sunken terminal boxes size 150mm x 75mm and 60mm deep, painted on both sides inside and outside with one coat of red oxide primer of suitable size for mounting of switches sockets, fan regulators etc with 3mm thick plastic laminated sheet cover size 150mm x 75mm etc making good to the disturbed surfaces of walls, maching the colour with existing surface complete all as specified and directed by Engineer-in-Charge.
10
-
-
... More
S&F in replacement of MS sunken box 1.6mm thick galvanised steel pressed sunken terminal boxes size 150mm x 150mm and 60mm deep, painted on both sides inside and outside with one coat of red oxide primer of suitable size for mounting of switches sockets, fan regulators etc with 3mm thick plastic laminated sheet cover size 150mm x 150mm etc making good to the disturbed surfaces of walls, maching the colour with existing surface complete all as specified and directed by Engineer-in-Charge.
8
-
-
... More
Taking down re-fixing only exhaust fans including self closing GI louvers off mode protection against birds etc mounted in suitable opening arrangement and connection up and including three core PVC insulated PVC sheathed copper conductor flexible cable 1.0 Sqmm drawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners 10mm dia 100mm long including hole in wall and making good the disturbed surfaces complete all as specified and directed.
20
-
-
... More
Taking down and re-fixing of Geyser and Solar Water System complete with accessories three core copper wire upto 5 mtr 4 Sqmm for connecting complete all as specified and directed.
20
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements