Military Engineer Services Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Military Engineer Services - MES Tender
Civil And Construction
Eprocure
Opening Date19 Sep 2024
Closing Date10 Oct 2024
Tender Amount₹ 40,00,000
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Repair To Barbed Wire Fencing, Chain Link Fencing, Security Wall, Hard Standing, Path, Certain Protective Works For Various E/m Installations And Repairs To Drain, Sewage Line, Septic Tank, Soakage Pit Etc In Md Accn And Otm Accn At Beas And Jandiala
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_665683_2Bid Award Id
ViewTender No
GE KPT- /2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Repair to barbed wire fencing, chain link fencing, security wall, hard standing, path, certain protective works for various E/M installations and Repairs to Drain, sewage Line, septic tank, soakage pit etc in Md Accn and OTM Accn at Beas and Jandiala Guru
Repair to barbed wire fencing, chain link fencing, security wall, hard standing, path, certain protective works for various E/M installations and Repairs to Drain, sewage Line, septic tank, soakage pit etc in Md Accn and OTM Accn at Beas and Jandiala Guru
Repair to barbed wire fencing, chain link fencing, security wall, hard standing, path, certain protective works for various E/M installations and Repairs to Drain, sewage Line, septic tank, soakage pit etc in Md Accn and OTM Accn at Beas and Jandiala Guru
BOQ Items
Excavation in post holes (or similar holes) each not exceeding 0.50 Cum, and getteing out, returning filing in and ramming earth with broken rubble mixed with earth around in layers not exceeding 25cm, watering etc and removing surplus soil not exceeding 50m and making good surface in loose/soft soil, complete all as specified and directed by Engr-in-Charge.
55
-
-
M&L for Cement concrete type C-2, 1:3:6 (40mm Graded stone agg) as in foundation, filling and mass concrete, complete all as specified and directed by Engr-in-Charge.
12
-
-
S&F mild steel works as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc including all necessary drilling, bolting or riveting flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting etc, and similar work conforming to Fe-290 Gde E-165, complete all as specified and directed by Engr-in-Charge.
1200
-
-
Supply only GI chain link fencing of any size or type, complete all as specified and directed by Engr-in-Charge.
1450
-
-
Fixing only GI chain link fencing of any size or type including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire, complete all as specified and directed by Engr-in-Charge.
315
-
-
S&F mild steel screw bolts (machine made) with hexagonal or Square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washer and one hexagonal or square nut, exceeding 5 cm but not exceeding 10 cm long, dia of shank 11 to 15 mm, complete all as specified and directed by Engr-in-Charge.
62
-
-
M&L for mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to complete all as specified and directed by Engr-in-Charge.
300
-
-
S&F galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire with staples or steel, complete all as specified and directed by Engr-in-Charge.
25
-
-
M&L for cement concrete type D2, 1:4:8 (40mm graded stone aggregate) as in foundations, filling and mass concrete, complete all as specified and directed by Engr-in-Charge.
85
-
-
Supplying and filling sand under floors or in foundations including watering and consolidation, complete all as specified and directed by Engr-in-Charge.
17.5
-
-
M&L for Machine pressed precast concrete interlocking paver block, 60mm thick, any shape and size, confirming to IS-15658-2006, M-40 Grade, with grey cement and no pigment, complete all as specified and directed by Engr-in-Charge.
700
-
-
Demolition of PCC in Ground floors/PCC Path/Plinth Protection and paving not exceeding 15cm thickness (below or above ground level) etc, complete all as specified and directed by Engr-in-Charge.
90
-
-
M&L for PCC 1:2:4, Type B1 (20 mm graded stone aggregate) as in bed blocks, coping, etc, complete all as specified and directed by Engr-in-Charge.
8
-
-
M&L for providing precast cement concrete type B-I, 1:2:4, as in kerb stone including chamfers, weatherings, throating etc. and setting in mortar 1:6 complete with joints to match, complete all as specified and directed by Engr-in-Charge.
30
-
-
M&L for chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors/path with grey cement and pigment to match over and including Screed bed or bedding layer of mortar 20 mm thick in cement mortar 1:4, complete all as specified and directed by Engr-in-Charge.
250
-
-
Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed by Engr-in-Charge.
70
-
-
M&L for Brick work with sub class 'B' bricks using old size bricks straight or curved on plan exceeding 6m mean radious built in CM 1:4 etc, complete all as specified and directed by Engr-in-Charge.
15
-
-
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6, complete all as specified and directed by Engr-in-Charge.
42
-
-
All as per item No 21 above but except bricks etc, complete all as specified and directed by Engr-in-Charge.
13
-
-
Taking down cement or cement lime plaster, any description on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed by Engr-in-Charge.
550
-
-
M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar 1:6 on walls finished even and smooth without using extra cement, complete all as specified and directed by Engr-in-Charge.
120
-
-
M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar 1:4 on walls finished even and smooth without using extra cement, complete all as specified and directed by Engr-in-Charge.
970
-
-
M&L for preparation of new plastered surfaces and applying two coats of cement base paint over and including a coat of chalk whiting/priming on plastered surfaces of walls, complete all as specified and directed by Engr-in-Charge.
810
-
-
M&L for preparation of new plastered surfaces and distempering walls with two coats of distemper oil emulsion, white or tinted over and including 1mm thick wall care putty including primer, complete all as specified and directed by Engr-in-Charge.
120
-
-
M&L for preparation of newly plastered surface of walls and applying two coats of exterior emulsion paint on walls over and including a coat of primer, complete all as specified and directed by Engr-in-Charge.
250
-
-
M&L for providing 35 mm thick precast cement concrete louvres and jallies, (measured solid), including all mouldings but excluding frame in cement conc type B0, 1:2:4 and set in CM 1:4, complete all as specified and directed by Engr-in-Charge.
105
-
-
M&L for Providing precast cement concrete as in posts to RCC jali, with plain fair faces, including chamfers, weatherings, throating etc. and setting in mortar complete with joints to match in cement cocncrete type B0, 1:2:4 and set in CM 1:4, complete all as specified and directed by Engr-in-Charge.
1.35
-
-
Demolition of RCC of any description and in any position not otherwise specifically provided for etc complete all as specified and directed by Engr-in-Charge.
7
-
-
M&L for Non-skid Ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.11sq. m but not exceeding 0.18sq. m, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete and including 15mm thick screed bed in cement mortar 1:6, complete all as specified and directed by Engr-in-Charge.
75
-
-
M&L for coloured glazed ceramic tiles in vertical surface 450x350x7 mm thick laid over and including10mm thick screed bed in cement mortar 1:4, set and jointed in neat cement slurry and pointed in white or colour cement to match, complete all as specified and directed by Engr-in-Charge.
175
-
-
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed by Engr-in-Charge.
250
-
-
Taking down rolling shutter of any description and size (Area exc 5 Sqm but not exc 10 Sqm), including covers and anchorging rod, complete all as specified and directed by Engr-in-Charge.
3
-
-
M&L for steel rolling shutter made out of M.S.sheet of 1mm thick, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer: erected in position as indicated, complete push pull or manual type, complete all as specified and directed by Engr-in-Charge.
18
-
-
Dismantling structural steel work including doors, gates etc.complete all as specified and directed by Engr-in-Charge.
2
-
-
M&L for Dismantling plain or corrugated Asbestos cement (corrugated, semi-corrugated,etc) sheets in roof coverings, complete all as specified and directed by Engr-in-Charge.
125
-
-
M&L for framed work as in post of parking shed, perline, doors or gates and chowkhats of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering doors, etc, to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening conforming to GdeFe 290(Gde E-165) complete all as specified and directed by Engr-in-Charge.
2000
-
-
M&L for pre-painted galvalumealuminium zinc coating GI based corrigated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engr-in-Charge.
125
-
-
M&L for preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over and including a coat of red oxide primer, complete all as specified and directed by Engr-in-Charge.
120
-
-
M&L for precast cement concrete type B-1, 1:2:4 as in cover slabs over drain/manholes etc. including necessary formwork, complete all as specified and directed by Engr-in-Charge.
6.75
-
-
M&L for TMT bars 10mm dia and over cut to length bent to shape required including cranking, hooking ends and binding with MS wire (annealed) not less than 0.90mm dia, complete all as specified and directed by Engr-in-Charge.
1000
-
-
Demolition and breaking up 150mm bore drain pipes (salt glazed ware or AC pipe) set in cement mortar and taking out from trenches, complete all as specified and directed by Engr-in-Charge.
220
-
-
Demolition and breaking up 200mm bore drain pipes (salt glazed ware or AC pipe) set in cement mortar and taking out from trenches complete, all as specified and directed by Engr-in-Charge.
160
-
-
M&L for clearing blockage of WC or EWC by opening inspection door bend and using Roding/pressure technique to clear blockage and removing the garbage out of the cantonment area without creating any nuisance and make the site neat & tidy, complete all as specified and directed by Engr-in-Charge.
800
-
-
M&L for clearing blockage of Gully/floor traps to first man hole by Roding/pressure to clear blockage and removing the garbage out of the cantonment area without creating any nuisance and make the site neat & tidy complete all as specified and directed by Engr-in-Charge.
Note:-
(a) In case on cleaning sewage line, the blockage of IWC/EWC & GT, FT to first manhole gets cleaned automatically then again if blocked within seven days then payment of later complaints, shall not be allowed.
(b) Similarly in case of cleaning of first manhole, IWC/EWC & GT, FT gets cleared & again it is blocked in within seven days then payment of later complaints shall not be allowed.
(c) Also in case on cleaning of sewage line between two manholes, blockage of IWC/EWC & GT, FT to first manhole gets cleared & again it is blocked within seven days then payment of later complaint shall not be allowed.
(d) JE(Civil) and Engineer-in-Charge shall be responsible for checking the actual position and payment irrespective of Nos of Complaints.
(e) In case clearing of blockage of sewage line not attended/ cleared by the contractor within 24 hours then recovery of Rs. 300/- each job shall be recovered from contractor.
1000
-
-
M&L for clearing blockage of sewage line between two manholes by pressure pumping/Roding and removing the garbage out of the cantonment area make the site neat & tidy complete all as specified and directed by Engr-in-Charge.
Note :
(a) In case on cleaning sewage line, the blockage of IWC/EWC & GT, FT to first manhole gets cleaned automatically then again if blocked within seven days then payment of later complaints, shall not be allowed.
(b) Similarly in case of cleaning of first manhole, IWC/EWC & GT, FT gets cleared & again it is blocked in within seven days then payment of later complaints shall not be allowed.
(c) Also in case on cleaning of sewage line between two manholes, blockage of IWC/EWC & GT, FT to first manhole gets cleared & again it is blocked within seven days then payment of later complaint shall not be allowed.
(d) JE(Civil) and Engineer-in-Charge shall be responsible for checking the actual position and payment irrespective of Nos of Complaints.
(e) In case clearing of blockage of sewage line not attended/ cleared by the contractor within 24 hours then recovery of Rs. 300/- each job shall be recovered from contractor.
750
-
-
Material and labour for pumping out liquid or semi liquid sludge from sewage wells or septic tanks of any size or any depth mechanically/honey sucker and an open trench shall be made for disposal/ evaporation of liquid sludge. After use, the whole area shall be covered with bleaching powder and covered with soil about 15cm thick complete all as specified and directed by Engr-in-Charge.
Note:- During the cleaning of sewage wells, the alertnate arrangements shall be made by contractor by temporary pumping for clearing sewage disposal.
1200
-
-
M&L for cleaning sewage lines dia 150mm or 200mm or 300mm as in main central sewage system irrespective of there depth by Roding and other mechanical methods and make it functional by removing & taken out sludge & also disposs off sludge out side MD land (Length of line shall be measured from manhole to manhole) complete all as specified and directed by Engr-in-Charge. Depth not exc 1.50m starting from GL.
5000
-
-
M&l for cleaning sewage lines dia 150mm or 200mm or 300mm as in main central sewage system irrespective of there depth by Roding and other mechanical methods and make it functional by removing & taken out sludge & also disposs off sludge out side MD land (Length of line shall be measured from manhole to manhole) complete all as specified and directed by Engr-in-Charge. Depth exceeding 1.5m but not exceeding 3.00m starting from GL.
800
-
-
M&L for cleaning of existing septic tank and sewage well (by closing the existing sewage system at last man hole and providing temporary Katcha drain for flow of sewage water), removing man hole cover and dewatering the liquid waste by mechanical pumping, removing the solid sludge mechanically up to the bottom of septic tanks and sewage well of any size including depositing the solid sludge in the pit providing by digging in near by septic tank of appropriate size, Covering the pit with bleaching powder and then by natural earth about 15cm thick layer, soil obtained from excavation after filling the solid sludge and making good completely hygienic, Opening the man hole after cleaning and relaying the man hole cover, complete all as specified and directed by Engr-in-Charge.
600
-
-
M&L for breaking up/puncturing existing badly blocked line and clearing the blockage by excavating line as a manhole of suitable depth and size at site complete all as specified and directed by Engr-in-Charge. [Different items involved in excavating brick work plastering etc will be paid under different items of Sch A (BOQ)].
5
-
-
M&L for soakage wells of size 3.00m dia & 4.50 m deep, excavation, in any type of soil, foundation in PCC 1:3:6 wells of honey combed brick masonry in cement mortor 1:4 and cover slab in RCC 1:1 1/2 : 3, type A-1 using 20mm graded crushed stone aggregate, PCC band in type B-1 (1:2:4) including interconnecting pipes, filling with brick bats, complete all as specified and directed by Engr-in-Charge.
3
-
-
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for foundation, laying of pipes including forming the bottom surface to required level etc, and for manholes not exceeding 10 Sq.m area on plan and for similar works and getting out complete all as specified and directed by Engr-in-Charge.
25
-
-
M&L for lean cement concrete 1:5:10 type E-2 using 40 mm graded stone aggregate as in filling and mass concrete, complete all as specified and directed by Engr-in-Charge.
5
-
-
M&L for cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregates) as in drains, coping, benching, water troughs, including weathering, slightly rounded or chamfered, and throating including form work complete all as specified and directed by Engr-in-Charge.
3.5
-
-
M&L for precast cement concrete as in cover slabs 1:2:4 type B-1 (using 20mm graded stone aggregates) set in cement mortar (1:6) complete after placing in position over septic tanks/manhole covers/drain covers, complete all as specified and directed by Engr-in-Charge.
6
-
-
M&L for Reinforced cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregates) as in slab of septic tank, soak well, etc supported on walls, beams & columns in floors, roofs, landings, balconies, canopies, deckslabs & in shelves & the like etc, complete all as specified and directed by Engr-in-Charge.
5
-
-
Use and waste of formwork with fair finished flat concrete surfaces such as soffits of suspended slab, such as roof slabs, floor slabs, landings & similar work, n exc 200mm thick, horizontal or sloping, complete all as specified and directed by Engr-in-Charge.
20
-
-
Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, complete all as specified and directed by Engr-in-Charge.
40
-
-
M&L for TMT bars 6 to 8 mm dia cut to length, bent to shape including cranking bending, and binding with MS wire (annealed) not less than 0.9 mm dia, complete all as specified and directed by Engr-in-Charge.
300
-
-
M&L for concrete bed to 150mm dia drain pipes in cement concrete (1: 4:8) type C-2 using 40mm graded crushed stone aggregate including packing under, and haunching against the sides of pipe after they are laid and tested complete all as specified and directed by Engr-in-Charge.
200
-
-
M&L for Concrete bed to 200mm dia drain pipes in cement concrete (1:4:8) type D-2 using 40mm graded crushed stone aggregate including packing under, and haunching against the sides of pipe after they are laid and tested complete all as specified and directed by Engr-in-Charge.
150
-
-
M&L for Reinforced concrete 150mm dia pipes, class NP2, laid and jointed complete with collars in trenches, on concrete bed to required slope, jointed and tested complete all as specified and directed by Engr-in-Charge (Excavation, earth work and concrete bed shall be measured and paid for separately under appropriate items of Sch 'A').
220
-
-
M&L for Reinforced concrete 200mm dia pipes, class NP2, laid and jointed complete with collars in trenches, on concrete bed to required slope, jointed and tested complete all as specified and directed by Engr-in-Charge (Excavation, earth work and concrete bed shall be measured and paid for separately under appropriate items of Sch 'A').
160
-
-
Returning filling in trenches including spreading leveling watering and well ramming in layers each not exc 25cm, complete all as specified and directed by Engr-in-Charge.
20
-
-
Removal of surplus soil to a distance n.exc 50m away and depositing where directed at a level n.exc 1.50 m above the starting point, complete all as specified and directed by Engr-in-Charge.
5
-
-
M&L for extra forming, fair, finished, drain or channel, 30cm inner girth in cement concrete using extra cement, complete all as specified and directed by Engr-in-Charge.
150
-
-
M&L for Cutting into existing manholes for connecting new drains, of any dia making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in cement concrete 1:2:4 type B1 (using 20mm graded crushed stone aggregates) finished smooth and reforming benching as required for 150 mm dia SGSW pipe, complete all as specified and directed by Engr-in-Charge.
6
-
-
M&L for Cutting into existing manholes for connecting new drains, of any dia making good to pipe and rendering , cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in cement concrete 1:2:4 type B1 (using 20mm graded crushed stone aggregates) finished smooth and reforming benching as required for 225 mm dia SGSW pipe, complete all as specified and directed by Engr-in-Charge.
4
-
-
S&F PVC (SWR) 110mm bore pipes single socketed, in any length with rubber ring joints fixed to walls, complete all as specified and directed by Engr-in-Charge.
130
-
-
S&F PVC (SWR) 75mm bore pipes single socketed, in any length with rubber ring joints fixed to walls, complete all as specified and directed by Engr-in-Charge.
50
-
-
S&F PVC (SWR) pipe, 110mm dia pipe, single socketed in any length with rubber ring joints, laid in trenches or in floors etc, complete all as specified and directed by Engr-in-Charge.
50
-
-
S&F PVC (SWR) bends ( any radius ) diminishing pleces or tapers 110mm bore, complete all as specified and directed by Engr-in-Charge.
30
-
-
S&F PVC (SWR) bends ( any radius ) diminishing pleces or tapers 150mm bore, complete all as specified and directed by Engr-in-Charge.
20
-
-
S&F 110mm bore PVC (SWRl) junction, single 'T' equal or unequal with access door, complete all as specified and directed by Engr-in-Charge.
10
-
-
S&F 110mm bore PVC (SWR) couplers, complete all as specified and directed by Engr-in-Charge.
20
-
-
S&F PVC (SWR) floor trap 75mm dia including jointing to waste pipe fixed in cement concrete 1:2:4 type B1 (including cutting in existing walls, removing the old and place the new pieces and making good the disturbed portion) complete all as specified and directed by Engr-in-Charge.
22
-
-
S&F PVC cowl 110mm bore fixed, with pipe, complete all as specified and directed by Engr-in-Charge.
10
-
-
Evaluation Notes How It Works ?