Odisha Hydro Power Corporation Limited Tender
Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.
Costs
EMD
₹ 91,300Document Cost
₹ 11,800Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_OHPCL_102488_1Tender No
e-Tender Call Notice No.73/2023-24 dated.12.03.2024Tender Authority
Odisha Hydro Power Corporation Limited ViewPurchaser Address
-Website
http://http://ohpcltd.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
(a) Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing for linear as well as curvilinear portions of the building for all heights and all levels, including: (a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminum cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including complete as required, as per architectural drawings, as per item decription, as specified, as per the approved shop drawings and as directed by Engineer-in-charge.
(b) Microwave cured EPDM gaskets, Bracketing system with MS hot dip galvanized Brackets designed to accomodated three dimesional movements with SS 316 Nut bolt with washers, SS 304 screws for all fabrication, SS 316 grade fasteners and anchor bolts of Hilti/Wurth, Nylon separators to prevent bi-metalic contacts, 1.00mm thich aluminum trims and flashing to seal the gaps between curtain wall and building structure all complete to required to perform as per specification in conjuction with BOQ. The EPDM Gaskets shall be of micro cured with shore A hardness of 60-65 Amee rubber or Maharastrapolymer or Osaka or Equivalent with micro curing facility shall be approved suppliers. c) The system design shall be based on pressureplate and cap system & desing shall include pressure equalization with minimum 2 barrier gaskets for improved wheather performance, drainage at all floors levels, Transon shall be overlap with mullion to have proper drainage to mullion. The design to accmmodate building movements, thermal expansions and the seismic movements. The system shall be designed considering surface temperature of 80-90 deg cel & temperature differential of 25 deg cel without creating excess stress in the system. All metal joints in the wet area shall be small joint sealant applied to ensure water tightness. Each glass panel shall be coushioned with EPDM gasket and press fitted with EPDM coushioned pressureplate.
(d) Providing and fixing in position flashings of solid aluminum sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.
(e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminum grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, vetted from IITs/NITs/reputed Govt. colleges and dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge.
824.04
2383107
2891.98
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12-6 mm insulated glass (double glazed) of Saint Gobain/Asahi India or equivalent make vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface of approved colour and shade reflective soft coating on surface of approved color and shade, an inner Heat strengthned clear innerlite glass 6mm thick, spacer tube 12mm wide filled with argon, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. for the required performances, as per the Architectural drawings & as per approved shop drawings, as specified and the IGU shall be assembled in the factory/workshop of the glass processor all compete etc. as directed by the Engineer-in-Charge. (i) Coloured tinted heat strenghened outerlite glass 6mm thick substrate with reflective soft coating on face #2, + 12mm gap filled with Argon + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 45% Light reflection internal 20 to 25%, light reflection external 20 to 25 %, shading coefficient (0.5-0.6) and U value of 2.8 to 3.0 W/m2 degree K etc. The above mentioned toughened glass shall strictly follow all its characteristics and strength performa to the latest Indian Standard Codal Provision No.IS 2553-1 (1990). The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
824.04
2581783
3133.08
20mm thick cement Plaster in cm (1:4) over RCC work including close deep chipping and slury treatment with all cost of materials, lead royalty and labour charges etc. complete as per direction of Engineer-in-Charge.
528
166230
314.83
Priming one coat with any approved primer on new plastered work as per direction of Engineer-in-Charge.
528
42625
80.73
Wall painting two coats with weather coat paint of approved shade on new work to give an even shade including cost of paint as per direction of Engineer-in-Charge.
528
48961
92.73
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements