Mahanadi Coalfields Limited Tender

... More
Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Mahanadi Coalfields Limited - MCL Tender

Works
Civil And Construction
Civil Works Others
Electrical and Electronics
Electrical Works
Eprocure
Opening Date14 Feb 2025
Closing Soon3 Mar 2025
Tender Amount₹ 4,91,75,120 
Notes
Download

AI Insights

Technical Capacity
... View More
The required prior work experience for the bidder includes: * Three similar completed works each costing not less than 40% of the estimated cost put to tender * Two similar completed works each costing not less than 50% of the estimated cost put to tender * One similar completed work costing not less than 80% of the estimated cost put to tender The cost of previous completed works shall be given a simple weightage of 5% per year to bring them to the current price level while evaluating the qualification requirement of the bidder. The date of completion of work should be during the last 7 years ending the last day of the month previous to the one in which bid applications are invited. In case of Joint Venture, the qualifying criteria parameter e.g. experience of the individual partners of the JV will be added together towards fulfilment of qualification criteria related to experience. The participating share of JV partners shall be as below: * Lead Partner shall have at least 50% participating share in JV * Other partners (s) shall have at least 20% participating share in JV The bidders are required to furnish the following information online: * Description of qualifying experience (similar nature) * Work order Number /Agreement Number of each experience * Name & address of Employer/Work Order Issuing authority of each experience * Percentage (%) share of each experience * Executed Value of work against each experience * Start date & end date of each qualifying experience (similar nature) A Satisfactory Work Completion Certificate issued by the employer against the experience of similar work is required. In case of a Joint Venture (JV), this certificate is required for individual partners, including the lead partner.

Costs

Summary

Facelifting Work Of 132kv Sub-station Colony - Repair Maintenance And Development Works Including Electrical Works.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)

40

4621

184874

... More
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete

100.8

252

25457.04

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Allworks upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum

140

7051

987189

... More
Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, buttererses, plinth and string courses etc.

1500

537

806850

... More
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform

350

619

216720

... More
steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth Ievel. Thermo-Mechanically Treated bars of grade Fe-500D or more

11200

97

1096480

... More
12 mm cement plaster finished with a floating coat of neat cement of mix 1:4 (1 cement: 4 fine sandl

1050

289

304132.5

... More
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slu.ry mixed with pigment to match the shade of tiles, including rubbin8 and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Dark shade pigment using ordinary cement

400

864

345640

... More
Paved Approach Road Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil

466.41

216

100767.88

... More
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.

233.21

864

201629.04

... More
Cast in Situ cement Concrete M 20 Kerb with Channel (Construction of cement 8.2 concrete kerb with channel with top and bottom width 250 and 300 mm respectively' 250 mm high in M 20 grade PCC on M1O grade foundation 150 mm thick' kerb channel 300 mm wide, 50 mm thick in PCC M2O grade, sloped towards the kerb' kerb sione with channel laid with kerb laying machine, foundation concrete laid manually' all com lete as r clause 409 Using concrete Mixer

1424.5

583

830483.5

... More
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.

1575

9

15513.75

... More
Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block makinS machine with stron8 vlbratory compaction, of approved iize, desiSn & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling thejoints with line sand etc. allcomplete a5 perthe direction of Engineer-in-charge.

2332.05

793

1850714.88

... More
Construction of Turf Paver Block Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil

508.6

216

109883.03

... More
Providing and laying 500x500x40 mm thick Turf paver (Turfpave XD) on 150 mm thick sub grade of compacted bed of 20 mm thick nominal size stone aggregate and base course and filling with 150 mm thick jamuna sand, including spreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer-in-charge.

2543

1302

3311367.45

... More
CAMPUS DEVELOPMENT Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.

32.5

216

7021.63

... More
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.

9.75

864

8429.85

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)

9.75

4621

45063.04

... More
Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in : Cement mortar 1:4 (1 cement : 4 coarse sand)

39

6652

259443.6

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes. channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of EnBineer-in- cha.ge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).

3640

803

2924558

... More
Earth work in surface excavation not exceeding 30 cm in depth but exceedingl.s m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, as per directions of Engineer in lncharge: All kinds of soil

2281.3

72

165622.38

... More
Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment)

228.13

253

57865.17

... More
Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).

273.76

42

11552.67

... More
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge

273.76

29

8007.48

... More
Providing and stacking of Bottle palm of ht. 150-180 cm bottom girth 20-25 cm well developed in big poly bags of size 25 cm as per direction of the officer-in-charge.

30

1070

32100

... More
Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material's as per direction of officer in charge (excluding cast of plant & water) Hedge Plant /Ground cover

5600

1

10920

... More
Providing and fixing of Tuflex Garden fencing Hexagonal net/or equivalent of green colour having contents (Weight grams/sqm. 510 (+/- 8%)) in width of 60 cm. with bamboo of 90 cm. length. The bamboo should bepainted with green colour paint of approved brand and manufacture (two or more coats) and fixed 30 cm.below ground level and 60 cm. above ground level at a distance of 1.50 mtrs. The net and bamboo should bebinded with 2 mm. G.I. Wire at three places properly as per direction of Engineer-in-charge.

30

314

9421.5

... More
Providing & laying Selection no. 1 doob grass turf wath earth 50mm to 50mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officer in charge

810

202

164065.5

... More
Supplying and spreading of sand in lawn area, including watering, and dressing complete

318

864

274942.8

... More
Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 20 mm

45.63

240

10980.86

... More
Fine dressing of the ground

2281.3

2

6729.84

... More
12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)

442

232

102610.3

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and anufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

442

142

63073.4

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 k&/10 sqm)

442

162

71780.8

... More
Providing and fixing SW-01-,Doubls Swing of Gl "C" class pipe, PP powder coating,FRP material like Golcoat & Resin are of Satyen brand Matt (Binani make) or equivalent as per approval of EIC.

1

33350

33350

... More
Providing and fixing SS-02-4 STR SEE SAW of Gl "C" class pipe, PP powder coating,FRP material like Golcoat & Resin are of Satyen brand Matt (Binani make) or equivalent as per approval of EIC.

1

24150

24150

... More
Providing and fixing SS-03-MULTI STR SEE SAW of Gl "C" class pipe, PP powder coating,FRP material like Golcoat & Resin are of Satyen brand Matt (Binani make) or equivalent as per approval of EIC.

1

20700

20700

... More
Providing and fixing CLT-07-MONKEY CLIMBER of Gl "C" class pipe, PP powder coating,FRP material like Golcoat & Resin are of Satyen brand Matt (Binani make) or equivalent as per approval of EIC.

1

33350

33350

... More
Providing and fixing CLT-10-LOOP RUNG of Gl "C" class pipe, PP powder coating,FRP material like Golcoat & Resin are of Satyen brand Matt (Binani make) or equivalent as per approval of EIC.

1

26450

26450

... More
Providing and fixing CLT-06-MAZE CLIMBER of Gl "C" class pipe, PP powder coating,FRP material like Golcoat & Resin are of Satyen brand Matt (Binani make) or equivalent as per approval of EIC.

1

57500

57500

... More
Providing and fixing MGR-01-FRP-PLATFORM MGR of Gl "C" class pipe, PP powder coating,FRP material like Golcoat & Resin are of Satyen brand Matt (Binani make) or equivalent as per approval of EIC.

1

40250

40250

... More
Providing and fixing DB-13-WHALE DUST BIN of Gl "C" class pipe, PP powder coating,FRP material like Golcoat & Resin are of Satyen brand Matt (Binani make) or equivalent as per approval of EIC.

6

11500

69000

... More
Providing and fixing DB-15-FISH DUST BIN of Gl "C" class pipe, PP powder coating,FRP material like Golcoat & Resin are of Satyen brand Matt (Binani make) or equivalent as per approval of EIC.

6

11500

69000

... More
C TYPE FACELIFTING - CIVIL Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.

0.58

1989

1153.68

... More
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.

232.45

30

7182.7

... More
12 mm cement plaster of mix ::1:6 (1 cement: 6 fine sand)

232.45

217

50546.25

... More
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete

542.39

11

6183.25

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

792.85

142

113139.69

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

792.85

162

128758.84

... More
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.

158.76

178

28386.29

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture

75.42

160

12108.68

... More
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emul sion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration

96

185

17769.6

... More
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/Lindane emulsifiable Concentration 20%

24

311

7474.8

... More
Reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources).

0.58

7475

4335.56

... More
Centering and shuttering including strutting, propping etc. and removal of form for vertical and horizontal fins individually or forming box louvers band, facias and eaves boards

9.42

1128

10629.06

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more

46.22

97

4524.94

... More
Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge. 25 mm average thickness

37.21

89

3332.16

... More
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick

27.31

1480

40432.45

... More
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.

14.22

1701

24190.35

... More
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make

1.72

477

820.7

... More
Providing & Applying high quality acrylic modified resin based texture of Dholpur/Red sand stone Pattern with anti algae and UV resistance properties to be applied as intermediate finish in desired pattern @ 43.04 kgs/10 sqm to form film of 1- 1.5 mm thickness after scrapping and properly cleaning the surface to remove loose particles from the plaster surface, followed by top coating with Premium Acrylic Smooth exterior paint with Silicone additives of required shade by two or more coats @ 1.43 litres/10 sqm, complete as the direction of Engineer -in-Charge.

96

446

42816

... More
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)

3

1363

4090.35

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)

3

6361

19084.2

... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-lll) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.

48

526

25293.6

... More
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)

54.36

196

10700.77

... More
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.

90.6

51

4661.37

... More
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers

54.36

73

4019.92

... More
C TYPE FACELIFTING - PLUMBING Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, Single socketed pipes. 110 mm diameter

36

362

13062.6

... More
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100 mm dia Sand cast iron S&S as per IS - 1729

6

449

2697.3

... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm

40

279

11166

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler 110 mm

12

177

2133

... More
Dismantling old C.I. pipes including excavation and refilling trenches after taking out the pipes, breaking lead caulked joints, melting of lead and making into blocks, including stacking of pipes at site lead up to 50 metre: 80 mm diameter C.I. pipe

36

237

8555.4

... More
Dismantling old C.I. pipes including excavation and refilling trenches after taking out the pipes, breaking lead caulked joints, melting of lead and making into blocks, including stacking of pipes at site lead up to 50 metre: Dismantling old C.I. pipes including excavation and refilling trenches after taking out the pipes, breaking lead caulked joints, melting of lead and making into blocks, including stacking of pipes at site lead up to 50 metre: 100 mm diameter C.I. pipe

36

248

8931.6

... More
Providing and fixing soil, waste and vent pipes : 100 mm dia Hubless centrifugally cast (spunl iron pipes epoxy coated inside & outside lS:15905

60

1008

60483

... More
Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.l./ C.l. Pipes : 100 mm dia pipe

36

132

4777.2

... More
Providing and fixint M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand:4 Sraded stone atgregate 20 mm nominal size), includlng cost of cutting holes and making good the walls etc. : For 100 mm dia pipe

36

280

10087.2

... More
Providing and fixing plain bend of required degree. 100 mm dia Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside lS:15905

8

362

2899.6

... More
Providing and fixing single equal plain junction of required degree : 100x100x100 mm Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per lS:15905

16

554

8865.6

... More
Constructing brick masonry chamber for underground C.l inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 roarse sand) C.l. cover with frame (light duty) 455x610 mm internal dimensions, total weight cover with frame to be not less than 38 kg (weight of 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: lnside dimensions 455x610 mm and 45 cm deep for single pipe line : Wilh fly ash Brick (230x115x75 mm size) bricks of class designation 10

4

5804

23217.8

... More
C TYPE FACELIFTING - WATER RECHARGE PIT Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soil

75.68

160

12139.07

... More
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.

0.24

864

207.5

... More
Brick work with Fly Ash Brick (230x115x75 mm size) bricks of class designation 10 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)

7.89

4897

38642.85

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)

5.44

4621

25142.86

... More
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete

9.87

252

2492.67

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)

2.12

6361

13486.17

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.

100

97

9790

... More
12 mm cement plaster of mix 1:6 (1 cement: 6 fine sand)

25.87

217

5625.43

... More
Neat cement punning.

25.87

59

1527.62

... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing ofjoints etc. complete : 150 mm dia. R.C.C. pipe

60

628

37689

... More
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge 150 mm nominal size dia

50

897

44890

... More
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge

3.16

1479

4676.01

... More
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, inrequired thickness, for all leads & lifts, all complete as per directionof Engineer-in-charge

3.16

1671

5281.62

... More
Gravel packing in tubewell construction in accordance with lS:4097, including providing gravel fine/ medaum/ coarse, in required grading & sizes a5 per actual requirement, all complete as per direction of Engineer an,charge.

4.24

1786

7575.18

... More
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mmto 2 mm in recharge pit, in required thickness over gravel layer, for all leads& lifts, all complete as per direction of Engineer -in-charge

3.16

1640

5182.56

... More
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, allcomplete for borewell of 150 mm dia

1

609

609.8

... More
Boring,/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in lS: 2800 (part l), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges oI all equipments. tools, plants & machineries required for the job, all complete as per direction of Engineer in charge, upto 90 metre depth below Ground level. All types of soil. 300 mm dia

50

502

25122.5

... More
C TYPE FACELIFTING - SURFACE DRAIN Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil

8.8

216

1901.24

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m .

5.87

173

1019.62

... More
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.

3.3

864

2853.18

... More
Half brick masonry with Fly Ash Brick (230x115x75 mm size) bricks of class designation 10 in foundations and plinth in : Cement Mortar 1:4 {l cement : 4 coarse sand)

20

626

12537

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)

4.4

4621

20336.14

... More
12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand)

44

232

10214.6

... More
Neat cement punning.

44

59

2598.2

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Allworks upto plinth level. Concrete of M25 grade with minimum cement content of 330 kg /cum

3.3

7051

23269.46

... More
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform

12.66

619

7839.07

... More
steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in positioh and binding all complete upto plinth Ievel. Thermo-Mechanically Treated bars of grade Fe-50OD or more

231

97

22614.9

... More
C TYPE FACELIFTING - PAVED APPROACH ROAD Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil

24

216

5185.2

... More
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.

12

864

10375.2

... More
Cast in Situ Cement Concrete M 20 Kerb with Channel (Construction of cement concrete kerb with channel with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M10 grade foundation 150 mm thick, kerb channel 300 mm wide, 50 mm thick in PCC M20 grade, sloped towards the kerb, kerb stone with channel laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409) Using concrete Mixer

32

583

18656

... More
Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.

120

793

95232

... More
PQC ROAD Excavation in Soil using hydraulic excavator and Tippers With Disposal upto 1000 meter (Excavation for roadwork ln soil With hydraulic excavator includings cutting and loading in tippers, trimming bottom and side Slopes in accordance with requirements of Lines Graded and cross Section and Transpoting to the Embakment Location with all Lift and Lead upto 1000m as per relevent clauses of Section 300 of Specification ). In Ordinary Soil

1500

77

115500

... More
Embankment Construction with Material Obtaitned from Borrow Pits ( Construction Of embakment with approved material having CBR 7, Obtained from borrow Pits with all Lifts and leads, Transporting to site , Spreading , Grading to required Slope and compacting to meet Reqirement of table 300-1, 300-2 and as per relevent clauses of section - 300 )

300

258

77400

... More
Construction ot granular sub-base by providing well graded material like natural sand crushed gravel or crushed stone having CBR 30, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method at OMC with rotavator and compacting with vibratory rollers of 80 to 100 kN static weight to achieve the desired density, complete as per Clause 40l of Specification. GSB with grading material -1

360

2115

761400

... More
Dry Lean Cement Concrete Sub- base (Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 26.5 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing as per clause 601 of specifications complete in all respect.

270

3247

876690

... More
Cement Concrete Pavement ( Construction of un-reinforced, dowel jointed, plain cement concrete pavement (minimum flexural strength - 4.5 Mpa) over a prepared sub base with cement @ 400 kg per cum (minimum), coarse and fine aggregate conforming to IS 383,maximum size of coarse aggregate not exceeding 31.5 mm, mixed in a batching and mixing plant as per approved mix design,transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, admixtures as approved,curing compound, finishing to lines and grades as per drawing as per IRC 15 2011 and as per relevant clauses of section 602 of specifications complete but excluding cost of steel in dowel bar and tie rods etc.

360

6187

2227320

... More
Cast in Situ Cement Concrete M 20 Kerb with Channel (Construction of cement concrete kerb with channel with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M10 grade foundation 150 mm thick, kerb channel 300 mm wide, 50 mm thick in PCC M20 grade, sloped towards the kerb, kerb stone with channel laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409) Using concrete Mixer

600

583

349800

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level: Mild steel and Medium Tensile steel bars

9000

69

623700

... More
Painting Two Coats on New Concrete Surfaces (Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces)

150

135

20250

... More
Painting lines, dashes, arrows etc on roads in two coats on new work with ready mixed road Grade-I marking paint concrete surface (cold applied reflective paint) conforming to IS:164 on bituminous surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control Over l0 cm in width Control.

60

216

12960

... More
ENTRANCE GATE - CIVIL Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil

84

216

18148.2

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

56

173

9727.2

... More
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.

10.5

317

3335.85

... More
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.

9.45

864

8170.47

... More
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: with chlorpyriphos/Lindane E.C. 20% with 1% concentration

77

185

14252.7

... More
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/Lindane emulsifiable Concentration 20%

19.25

311

5995.41

... More
Brick work withFly Ash Brick (230x115x75 mm saze) bricks of class designation 10 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)

4.1

4897

20080.57

... More
Brick work withFly ash Brick (23Ox115x7S mm size) bricks of class designation 10 in superstructure above plinth level up to floor V level in all shapes and sizes in in Cement mortar 1:6 (1 cement : 6 Coarse sand)

33.97

6059

205849.71

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)

11.55

4621

53382.37

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level. Concrete of M25 grade with minimum cement content of 330 kg /cum

31.26

7051

220425.2

... More
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete

46.72

252

11799.14

... More
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilever

549.28

505

277798.36

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum

86.04

8151

701385.17

... More
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platfor

265.06

619

164125.15

... More
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts

215.51

649

140070.72

... More
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. Sutset plates at the junctions and corners, all necessary fittings complete, includinB applying a priming coat of approved steel primer. UsinB M.S. angels 40x40x6 mm for diagonal braces

3.15

4660

14679.63

... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

1462.5

145

212940

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.

3449.41

97

337697.24

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more

12113.57

97

1185918.5

... More
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.

158.4

178

28321.92

... More
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.

2

192

384.6

... More
12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)

836.86

217

181975.21

... More
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)

46

196

9055.1

... More
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats.

145.66

105

15345.28

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand and manufacture

50.62

160

8127.04

... More
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size (Size of Tile 600 x 600 mm )

24.9

1242

30946.96

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and anufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

882.86

142

125984.12

... More
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm

737.2

238

176043.36

... More
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately.For the purpose of measurement the entire treated surface will be measured.

21

615

12926.55

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)

42.16

572

24121.84

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)

50.49

658

33240.09

... More
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width

6.2

90

563.27

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-incharge . (Cost of aluminium snap beading shall be paid in basic item) With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)

31.68

1323

41937.98

... More
COMPOUND WALL Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilever

232.5

505

117586.88

... More
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts

390

649

253480.5

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Allworks above plinth level upto floor V level. Concrete of M25 grade with min imu m cement content of 330 kg /cum

58.31

8151

475334.37

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in positioh and binding all complete above plinth Ievel. Thermo-Mechanically treated bars of grade Fe500 or more

5831.25

97

570879.38

... More
12 mm cement plaster of mix 1:6 (1 cement: 6 fine sand)

558

217

121337.1

... More
Brick work with non modular fly ash bricks ( Raise of Boundary Wall )

174.38

6428

1121001.83

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

3255

162

528612

... More
Providing and fixing concertina coil fencing with punched tapeconcertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apartand with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)

775

295

229043.5

... More
Structural steel work in single section, fixed with or without connecting plate. including cutting, hoistin& fixing in position and applying a priming coat of approved steel primer all complete.

732.38

99

73054.91

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture

13.95

160

2239.67

... More
Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars.

36.38

1820

66238.89

... More
RCC DRAIN IN ROAD CROSSING Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil

23.76

216

5133.35

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m .

15.84

173

2751.41

... More
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.

1.98

864

1711.91

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)

1.98

4621

9151.26

... More
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete

3.64

252

919.18

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level. Concrete of M25 grade with minimum cement content of 330 kg /cum

18.48

7051

130308.95

... More
Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, buttererses, plinth and string courses etc.

36.26

537

19504.25

... More
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform

9.71

619

6012.43

... More
steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth Ievel. Thermo-Mechanically Treated bars of grade Fe-500D or more

1663.2

97

162827.28

... More
12 mm cement plaster finished with a floating coat of neat cement of mix 1:4 (1 cement: 4 fine sandl

43.2

289

12512.88

... More
B TYPE FACELIFTING - CIVIL Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.

1.65

1989

3282.02

... More
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.

688.79

30

21283.61

... More
12 mm cement plaster of mix ::1:6 (1 cement: 6 fine sand)

688.79

217

149777.39

... More
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete

1607.17

11

18321.74

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

2266.58

142

323440.97

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

2266.58

162

368092.59

... More
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.

355.32

178

63531.22

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture

186.17

160

29889.59

... More
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emul sion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration

348

185

64414.8

... More
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/Lindane emulsifiable Concentration 20%

87

311

27096.15

... More
Reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources).

1.65

7475

12333.91

... More
Centering and shuttering including strutting, propping etc. and removal of form for vertical and horizontal fins individually or forming box louvers band, facias and eaves boards

27.01

1128

30476.73

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more

131.65

97

12888.54

... More
Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge. 25 mm average thickness

84.85

89

7598.32

... More
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick

70.65

1480

104597.33

... More
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.

30.72

1701

52259.33

... More
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make

5.06

477

2414.38

... More
Providing & Applying high quality acrylic modified resin based texture of Dholpur/Red sand stone Pattern with anti algae and UV resistance properties to be applied as intermediate finish in desired pattern @ 43.04 kgs/10 sqm to form film of 1- 1.5 mm thickness after scrapping and properly cleaning the surface to remove loose particles from the plaster surface, followed by top coating with Premium Acrylic Smooth exterior paint with Silicone additives of required shade by two or more coats @ 1.43 litres/10 sqm, complete as the direction of Engineer -in-Charge.

348

446

155208

... More
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)

6

1363

8180.7

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)

6

6361

38168.4

... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-lll) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.

174

526

91689.3

... More
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)

73.14

196

14397.61

... More
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.

121.9

51

6271.76

... More
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers

73.14

73

5408.7

... More
B TYPE FACELIFTING - PLUMBING Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, Single socketed pipes. 110 mm diameter

120

362

43542

... More
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100 mm dia Sand cast iron S&S as per IS - 1729

12

449

5394.6

... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm

60

279

16749

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler 110 mm

40

177

7110

... More
Dismantling old C.I. pipes including excavation and refilling trenches after taking out the pipes, breaking lead caulked joints, melting of lead and making into blocks, including stacking of pipes at site lead up to 50 metre: 80 mm diameter C.I. Pipe

120

237

28518

... More
Dismantling old C.I. pipes including excavation and refilling trenches after taking out the pipes, breaking lead caulked joints, melting of lead and making into blocks, including stacking of pipes at site lead up to 50 metre: 100 mm diameter C.I. pipe

120

248

29772

... More
Providing and fixing soil, waste and vent pipes : 100 mm dia Hubless centrifugally cast (spunl iron pipes epoxy coated inside & outside lS:15905

280

1008

282254

... More
Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.l./ C.l. Pipes : 100 mm dia pipe

120

132

15924

... More
Providing and fixint M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand:4 graded stone atgregate 20 mm nominal size), includlng cost of cutting holes and making good the walls etc. : For 100 mm dia pipe

120

280

33624

... More
Providing and fixing plain bend of required degree. 100 mm dia Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside lS:15905

16

362

5799.2

... More
Providing and fixing single equal plain junction of required degree : 100x100x100 mm Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per lS:15905

32

554

17731.2

... More
Constructing brick masonry chamber for underground C.l inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 roarse sand) C.l. cover with frame (light duty) 455x610 mm internal dimensions, total weight cover with frame to be not less than 38 kg (weight of 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: lnside dimensions 455x610 mm and 45 cm deep for single pipe line : Wilh fly ash Brick (230x115x75 mm size) bricks of class designation 10

8

5804

46435.6

... More
B TYPE FACELIFTING - WATER RECHARGE PIT Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soil

151.37

160

24279.75

... More
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.

0.48

864

415.01

... More
Brick work with Fly Ash Brick (230x115x75 mm size) bricks of class designation 10 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)

15.78

4897

77285.71

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)

10.89

4621

50331.95

... More
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete

19.74

252

4985.34

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)

4.23

6361

26908.72

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.

200

97

19580

... More
12 mm cement plaster of mix 1:6 (1 cement: 6 fine sand)

51.74

217

11250.86

... More
Neat cement punning.

51.74

59

3055.25

... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing ofjoints etc. complete : 150 mm dia. R.C.C. pipe

120

628

75378

... More
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge 150 mm nominal size dia

100

897

89780

... More
Supplying, filling, spreading & leveling stone boulders of size range5 cm to 20 cm, in recharge pit, in the required thickness, for allleads & lifts, all complete as per direction of Engineer-in-charge

6.32

1479

9352.02

... More
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, inrequired thickness, for all leads & lifts, all complete as per directionof Engineer-in-charge

6.32

1671

10563.25

... More
Gravel packing in tubewell construction in accordance with lS:4097, including providing gravel fine/ medaum/ coarse, in required grading & sizes a5 per actual requirement, all complete as per direction of Engineer an,charge.

8.48

1786

15150.37

... More
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mmto 2 mm in recharge pit, in required thickness over gravel layer, for all leads& lifts, all complete as per direction of Engineer -in-charge

6.32

1640

10365.12

... More
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, allcomplete for borewell of 150 mm dia

2

609

1219.6

... More
Boring,/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in lS: 2800 (part l), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges oI all equipments. tools, plants & machineries required for the job, all complete as per direction of Engineer in charge, upto 90 metre depth below Ground level. All types of soil. 300 mm dia

100

502

50245

... More
B TYPE FACELIFTING - SURFACE DRAIN Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil

319

216

68919.95

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m .

212.67

173

36940.78

... More
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.

119.63

864

103432.1

... More
Half brick masonry with Fly Ash Brick (230x115x75 mm size) bricks of class designation 10 in foundations and plinth in : Cement Mortar 1:4 {l cement : 4 coarse sand)

36.25

626

22723.31

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)

159.5

4621

737185.08

... More
12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand)

1595

232

370279.25

... More
Neat cement punning.

1595

59

94184.75

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Allworks upto plinth level. Concrete of M25 grade with minimum cement content of 330 kg /cum

119.63

7051

843553

... More
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform

458.93

619

284169.46

... More
steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in positioh and binding all complete upto plinth Ievel. Thermo-Mechanically Treated bars of grade Fe-50OD or more

8373.75

97

819790.13

... More
B TYPE FACELIFTING - PAVED APPROACH ROAD Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil

99.2

216

21432.16

... More
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.

49.6

864

42884.16

... More
Cast in Situ Cement Concrete M 20 Kerb with Channel (Construction of cement concrete kerb with channel with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M10 grade foundation 150 mm thick, kerb channel 300 mm wide, 50 mm thick in PCC M20 grade, sloped towards the kerb, kerb stone with channel laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409) Using concrete Mixer

92

583

53636

... More
Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.

496

793

393625.6

... More
A TYPE FACELIFTING - CIVIL Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.

1.53

1989

3043.32

... More
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.

782.43

30

24177.09

... More
12 mm cement plaster of mix ::1:6 (1 cement: 6 fine sand)

782.43

217

170139.4

... More
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete

1825.66

11

20812.52

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

2751.23

142

392600.52

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

2751.23

162

446799.75

... More
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.

842.4

178

150621.12

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture

248.16

160

39842.09

... More
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration

264

185

48866.4

... More
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/Lindane emulsifiable Concentration 20%

66

311

20555.7

... More
Reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources).

1.53

7475

11436.9

... More
Centering and shuttering including strutting, propping etc. and removal of form for vertical and horizontal fins individually or forming box louvers band, facias and eaves boards

25.69

1128

28987.31

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more

122.32

97

11975.13

... More
Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge. 25 mm average thickness

127.28

89

11397.92

... More
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick

105.98

1480

156903.39

... More
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.

46.08

1701

78388.99

... More
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make

5.3

477

2528.9

... More
Providing & Applying high quality acrylic modified resin based texture of Dholpur/Red sand stone Pattern with anti algae and UV resistance properties to be applied as intermediate finish in desired pattern @ 43.04 kgs/10 sqm to form film of 1- 1.5 mm thickness after scrapping and properly cleaning the surface to remove loose particles from the plaster surface, followed by top coating with Premium Acrylic Smooth exterior paint with Silicone additives of required shade by two or more coats @ 1.43 litres/10 sqm, complete as the direction of Engineer -in-Charge.

264

446

117744

... More
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)

6

1363

8180.7

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)

6

6361

38168.4

... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-lll) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.

132

526

69557.4

... More
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)

135.91

196

26753.88

... More
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.

113.26

51

5827.23

... More
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers

135.91

73

10050.54

... More
A TYPE FACELIFTING - PLUMBING Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, Single socketed pipes. 110 mm diameter

160

362

58056

... More
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100 mm dia Sand cast iron S&S as per IS - 1729

16

449

7192.8

... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm

80

279

22332

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler 110 mm

54

177

9598.5

... More
Dismantling old C.I. pipes including excavation and refilling trenches after taking out the pipes, breaking lead caulked joints, melting of lead and making into blocks, including stacking of pipes at site lead up to 50 metre: 80 mm diameter C.I. pipe

160

237

38024

... More
Dismantling old C.I. pipes including excavation and refilling trenches after taking out the pipes, breaking lead caulked joints, melting of lead and making into blocks, including stacking of pipes at site lead up to 50 metre: 100 mm diameter C.I. pipe

160

248

39696

... More
Providing and fixing soil, waste and vent pipes : 100 mm dia Hubless centrifugally cast (spunl iron pipes epoxy coated inside & outside lS:15905

224

1008

225803.2

... More
Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.l./ C.l. Pipes : 100 mm dia pipe

96

132

12739.2

... More
Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand:4 graded stone atgregate 20 mm nominal size), includlng cost of cutting holes and making good the walls etc. : For 100 mm dia pipe

96

280

26899.2

... More
Providing and fixing plain bend of required degree. 100 mm dia Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside lS:15905

16

362

5799.2

... More
Providing and fixing single equal plain junction of required degree : 100x100x100 mm Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per lS:15905

32

554

17731.2

... More
Constructing brick masonry chamber for underground C.l inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 roarse sand) C.l. cover with frame (light duty) 455x610 mm internal dimensions, total weight cover with frame to be not less than 38 kg (weight of 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: lnside dimensions 455x610 mm and 45 cm deep for single pipe line : Wilh fly ash Brick (230x115x75 mm size) bricks of class designation 10

8

5804

46435.6

... More
A TYPE FACELIFTING - WATER RECHARGE PIT Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soil

151.37

160

24279.75

... More
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.

0.18

864

155.63

... More
Brick work with Fly Ash Brick (230x115x75 mm size) bricks of class designation 10 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)

15.78

4897

77285.71

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)

10.89

4621

50331.95

... More
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete

19.74

252

4985.34

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)

4.23

6361

26908.72

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.

200

97

19580

... More
12 mm cement plaster of mix 1:6 (1 cement: 6 fine sand)

51.74

217

11250.86

... More
Neat cement punning.

51.74

59

3055.25

... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing ofjoints etc. complete : 150 mm dia. R.C.C. pipe

120

628

75378

... More
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge 150 mm nominal size dia

100

897

89780

... More
Supplying, filling, spreading & leveling stone boulders of size range5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge

6.32

1479

9352.02

... More
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, inrequired thickness, for all leads & lifts, all complete as per directionof Engineer-in-charge

6.32

1671

10563.25

... More
Gravel packing in tubewell construction in accordance with lS:4097, including providing gravel fine/ medaum/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer an,charge.

8.48

1786

15150.37

... More
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mmto 2 mm in recharge pit, in required thickness over gravel layer, for all leads& lifts, all complete as per direction of Engineer -in-charge

6.32

1640

10365.12

... More
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, allcomplete for borewell of 150 mm dia

2

609

1219.6

... More
Boring,/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in lS: 2800 (part l), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges oI all equipments. tools, plants & machineries required for the job, all complete as per direction of Engineer in charge, upto 90 metre depth below Ground level. All types of soil. 300 mm dia

100

502

50245

... More
A TYPE FACELIFTING - SURFACE DRAIN Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil

26.4

216

5703.72

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m .

17.6

173

3057.12

... More
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.

9.9

864

8559.54

... More
Half brick masonry with Fly Ash Brick (230x115x75 mm size) bricks of class designation 10 in foundations and plinth in : Cement Mortar 1:4 {l cement : 4 coarse sand)

60

626

37611

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)

13.2

4621

61008.42

... More
12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand)

132

232

30643.8

... More
Neat cement punning.

132

59

7794.6

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Allworks upto plinth level. Concrete of M25 grade with minimum cement content of 330 kg /cum

9.9

7051

69808.36

... More
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform

37.98

619

23517.22

... More
steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in positioh and binding all complete upto plinth Ievel. Thermo-Mechanically Treated bars of grade Fe-50OD or more

693

97

67844.7

... More
A TYPE FACELIFTING - PAVED APPROACH ROAD Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil

40.8

216

8814.84

... More
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.

20.4

864

17637.84

... More
Cast in Situ Cement Concrete M 20 Kerb with Channel (Construction of cement concrete kerb with channel with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M10 grade foundation 150 mm thick, kerb channel 300 mm wide, 50 mm thick in PCC M20 grade, sloped towards the kerb, kerb stone with channel laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409) Using concrete Mixer

50

583

29150

... More
Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.

204

793

161894.4

... More
ELECTRICAL - POINT WIRING Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. Group – C

6

1365

8190

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular plate etc required.

2

413

826

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.

1

512

512

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required Telephone socket outlet Each

1

121

121

... More
S/F Modular Boxes, base & cover plate: Supplying and fixing following size / modules GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 module (75 mm x 75 mm)

1

244

244

... More
ELECTRICAL - DISTRIBUTION BOARDS Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc as required.( but without MCB/RCCB/ Isolator). 8 way , Double door

1

2507

2507

... More
S/F 'C' series 5A to 32 A MCB: Supplying and fixing 240 volts, 'C' curve, 10kA miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required. Single Pole

4

247

988

... More
S/F 'C' series 5A to 32 A MCB: Supplying and fixing 240 volts, 'C' curve, 10kA miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required. Double Pole

1

663

663

... More
ELECTRICAL - SUB MAIN AND CIRCUIT WIRING Circuit / Sub-main wiring in PVC Conduit: Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required. 2 X 6 sq. mm + 1X 6 sq. mm earth wire

50

392

19600

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as reqired. 3 X 2.5 sq. mm (For circuit wiring)

40

126

5040

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as reqired. Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as reqired. 3 X 4.0 sq. mm (For power point wiring)

20

191

3820

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm

48

116

5568

... More
ELECTRICAL - LIGHT FITTINGS AND FANS S/F Ceiling Rose: Supplying and fixing 2 pin 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.

7

69

483

... More
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

6

149

894

... More
Supplying and fixing brass batten/ angle holder including connection etc. as required

4

98

392

... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC , earthing etc. complete as required

2

2420

4840

... More
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Upto 450 mm sweep

1

334

334

... More
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes

1

150

150

... More
22W LED BATTEN PLUS LUMILINE: Supply of 20W surface and wall mounted LED with aluminium housing & integrated electronic driver.

4

673

2692

... More
LED Bulb 10W : Supplying and fixing of LED 10W bulb and accessories as required.

4

116

464

... More
Supply of sizes 300 mm, 230 v A.C. heavay duity exhaust fan complete with motor,blades,frame, bracket, lover/shutter etc. as required of Greatwhite or apporoved equivalent.

1

1365

1365

... More
ELECTRICAL - EARTHING Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. (for street light poles)

11

6471

71181

... More
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.

110

551

60610

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

760

61

46360

... More
ELECTRICAL - MV CABLE Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ metal pipe as required. Upto 35 sq. mm

1100

25

27500

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 35 sq. mm (32mm)

1

318

318

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm (38mm)

2

268

536

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 6 sq. mm (19mm)

8

187

1496

... More
Supplying and making Outdoor termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 35 sq. mm

1

1602

1602

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)

990

127

125730

... More
MV Cable:- Supply of ISI marked aluminium cable conductor XLPE PVC insulated cable as per IS:7098 armoured, served, sheathed, 1100V grade with Termination and Laying of cable. 4CX35 sq. mm

200

401

80200

... More
MV Cable:- Supply of ISI marked aluminium cable conductor XLPE PVC insulated cable as per IS:7098 armoured, served, sheathed, 1100V grade with Termination and Laying of cable. 4CX16 sqmm

100

257

25700

... More
MV Cable:- Supply of ISI marked aluminium cable conductor XLPE PVC insulated cable as per IS:7098 armoured, served, sheathed, 1100V grade with Termination and Laying of cable. 2CX6 sq. mm

800

141

112800

... More
STREET LIGHT JB TO LUMINARIES Supply & drawing of 2CX1.5 Sq. Of FRLS PVC insulated Cu.single core cable in the existing surface/ recessed steel/ PVC conduit as required.

189

62

11718

... More
Providing and fixing MV. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required

2

229

458

... More
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) of size 60 cm X 60 cm at the bottom and 50cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.

10

498

4980

... More
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.

10

411

4110

... More
Supplying of 7 Mtr hight octagonal hot Dip galvanized pole (BOP-9031) With top dia 70mm, bottom dia 130 mm and made 3 mm thiek sheet , base plate dimensions 200x200x16mm (LXBXT) with door and locking arrangement sheet,neutral link, suitable 6A MCB , 4 way 63 Amp terminal block suitable to receive PVC armoured cable fixed on suitable size Baketillte sheet base complete or any other electrical accessory including suitable sizes of foundation bolt all complete as required . (without Arm)

21

13624

286104

... More
Supplying of 7 Mtr hight octagonal hot Dip galvanized pole (BOP-9031) With top dia 70mm, bottom dia 130 mm and made 3 mm thiek sheet , base plate dimensions 200x200x16mm (LXBXT) with door and locking arrangement sheet,neutral link, suitable 6A MCB , 4 way 63 Amp terminal block suitable to receive PVC armoured cable fixed on suitable size Baketillte sheet base complete or any other electrical accessory including suitable sizes of foundation bolt all complete as required . Single arm, 1500 mm

20

2122

42440

... More
Supplying of 7 Mtr hight octagonal hot Dip galvanized pole (BOP-9031) With top dia 70mm, bottom dia 130 mm and made 3 mm thiek sheet , base plate dimensions 200x200x16mm (LXBXT) with door and locking arrangement sheet,neutral link, suitable 6A MCB , 4 way 63 Amp terminal block suitable to receive PVC armoured cable fixed on suitable size Baketillte sheet base complete or any other electrical accessory including suitable sizes of foundation bolt all complete as required . Double arm, 1500 mm

1

3537

3537

... More
Erection of metalic pole of following length in cement concrete1:3:6( 1 cement: 3 coarse: 6 grade stone aggregate 40mm nominal size) foundation including excavation & refilling etc. as required 6.5 m to 8.0 m

21

4848

101808

... More
Supplying and fixing of 70 Watt New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07.Complete with all fixing accessories as required

22

6289

138358

... More
120W LED FLOOD LIGHT: Supply , installation, testing and commissioning of 120W, LED, flood light. High pressure die cast aluminium material with integrated optics, asymmetric wide beam LED flood light. Protection :IP66

6

10538

63228

... More
Supplying and erecting 12.5 m (clear height) motorized high-mast (Top -150mm, Bottom- 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per BSEN - 10025 S355/E350 & 3mm thickness, with base plate 25 mm thick x OD 520 mm grade as per IS-2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, SG-DG U clamps, double drum with assembly 250 kg, 5x2.5 Sq.mm. flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaries and its control gear box, lightning arrestor, arrangement for fixing aviation light, night glow reflector on pole at suitable height, high-mast with serial number, factory inspection report/test report of high-mast should be provided as per specifications on provided foundation J type stud/bolts with double check nuts & necessary accessories complete.

1

231495

231495

... More
Supplying and erecting outdoor stand mounted feeder pillar for high-mast of the same manufacturer with 32A TPN MCB incomer, 24hr astronomical time switch with minimum 5 years battery backup, 25 A TP contactor for automatic switching of luminaries, 2 no. 9A contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 SWG CRCA sheet box with supporting angles, self lock, gasket and slanting top erected on CC foundation complete.

1

24008

24008

... More
LED Post top Opel of 40W : Supply and fitting of new generation , LED post top energy saving enviromental friendly, spun aluminium housing with decorative polycarbonate diffuser IP65 protection.

4

7244

28976

... More
Bollard :- Providing, fitting, fixing and testing of Bollard light decorative luminaire light fixture of 800mm in length (IP-66) 10W LED Lamp with foundation, commissioning, testing with all other accessories as per drawing provided at the time of work execution or as per the direction of E/I)

25

5445

136125

... More
ELECTRICAL - FEEDER PILLAR Design, manufacturer, supply, testing and commissioning of Required with 2.5mm thick sheet metal enclosure, powder coated, weather proof, double door type feeder pillar with godown lock and padlock complete with interconnection with copper wires, LED indicating lights, providing holes for the glands. The base frame shall have angle iron of 50mm x 50mm x6mm of required size with 600mm long legs of MS angle and coverage of underground cable under feeder pillar with 2.5 mm thick sheet, 450mm in width all round the base frame including grouting the feeder pillar in 1:4:8 cement concrete complete as required. Feeder Pillar shall be suitable for 415V, 3-Phase, Four wire, 50 Hz supply complete with earth bus and lifting hooks as required. Approval shall be taken for each panel before fabrication. (All hardwares like nuts and bolts used shall be Galvanized and Zinc passivated )

1

57865

57865

... More
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC

1

413236

413236.3



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.