Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_MES_362822_3Bid Award Id
ViewTender No
8333/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Excavation over areas n.exc 1.5m deep & getting out soft/loose soil.
22
-
-
Excavation over areas exc 1.5m deep & n.exc 3 m deep and getting out in soft/loose soil
18
-
-
Excavation of post holes (or similar holes) each n.exc 0.5 cum getting out returning filing in and ramming earth or broken ruble mixed with earth around in layer n exc 25 cm and getting out soft/loose soil.
25
-
-
M &L for excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth, for foundation ,getting out soft/loose soil.
36
-
-
Returning filling in including spreding, leveling, watering, and well ramming in layer n exc 25 cm and getting out soft/loose soil.
37
-
-
Removing excavated material exc 250 m but n exc 500 and deposting where directed.
85
-
-
M&L for brocken stone or boulders hardcore of gauge n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surfaces all as specified and directed.
27
-
-
M&L for PCC 1:4:8 type D-2 (using 40 mm graded stone) as in filling and mass concrete.
4.5
-
-
M&L PCC 1:4:8 type D-2 75mm thick as in sub base of floor.
83
-
-
M & L 100 mm th PCC 1:3:6 type C-2 as in floor, finished even and fair complete all as specified.
119
-
-
M&L for 100 mm thick cement concrete in sub base type D-2, 1:4:8 (40 mm graded aggregate) all as specified and directed.
36
-
-
M&L PCC 1:3:6 Type C-2 (using 40mm graded stone aggregate) as in plinth protection, foot path, paved area, etc finished even and fair without using extra cement 75mm thick complete all as specified and directed.
57
-
-
M & L PCC 1:3:6 type C-2 s(using 40mm grade stone aggregate as in foundation etc and mass concrete.
7.5
-
-
M & L for PCC (1:3:6) type C-2 using 40mm graded aggregate as bond stone including necessary form work complete all as specified.
3.35
-
-
M & L for PCC (1:3:6) type C-2 using 40mm graded aggregate as in coping including necessary form work all as specified and directed
0.4
-
-
M&L 100mm thick Cement concrete 1:2:4 type B- 2, (40mm graded aggregate) as in floor finished
32
-
-
PCC (1:2:4) type B-2 using 40mm graded stone aggregate as in channels of man holes.
0.45
-
-
PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in band coping bed plate, benching etc including slightly rounded of chamfered angle, throating, etc complete all as specified and as directed.
0.4
-
-
Precast RCC (1:2:4) type B-1 in manhole/soack well/septic tanks slabs/covers etc including necessary form work complete set in cement mortar 1:6 complete.
0.5
-
-
M&L Cement concrete 1:3:6 type C-1 (20 mm graded agg ) in surface channels and drains.
3.1
-
-
Material and labour Reinforced cement concrete (Nominal Mix) in cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in cover slabs of drains, manholes, septic tanks, soakage wells etc. complete all as specified & as directed by Engineer-in-charge.
Note: - Reinforcement shall be measured and paid for separately.
0.8
-
-
Extra for forming fair finished surfaces of drain or channels, inner girth 30 cms, using extra cement including forms, moulds mitred/ stopped ends etc., complete.
51
-
-
S/F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws all as specified and as directed.
226
-
-
S & F 0.50mm thick pre-painted galvalume aluminiun zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall , ridge and velly complete all as specified and directed.
30
-
-
M& L for brick work with sub class B brick straight or curved on plan exc 6.00 m mean radius built in cement morter 1:6.
32.75
-
-
M&L brick work with sub class B bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4
29
-
-
Material and labour for brickwork in cement mortar 1:6 with sub class `B' bricks in one brick thick honey comb walling,etc
7.64
-
-
Material and labour for brick work in cement mortar 1:4 with sub class `B' bricks straight or curved on plan exceeding 6m mean radius with old size bricks as in pillars complete all as specified.
21
-
-
M&L for rendering 10 mm thick on other than fairs surfaces of brick wall in cm 1:6 in on wall.
135
-
-
M & L rendering 15mm thick in cement mortar 1:6 on fair faces of brick or concrete work even and smooth without using extra cement.
57
-
-
M & L rendering 15mm thick on cement mortar 1:4 brick or concrete work finished the surface even and smooth without using extra cement..
135
-
-
M&L for rendering 5mm thick plaster in CM 1:3 on fair faces of brick or concrete work finished even and smooth without using extra cement as in ceiling.
5
-
-
15mm thick cement plaster in cement mortar (1:4) on brick or concrete surface mixed with water proofing compound as per manufactures instructions, finishing the surface even and smooth without using extra cement complete all as specified.
26.88
-
-
Supply only integral water proofing compound (ISI marked)
7.48
-
-
S&F dividing strip 30 mm width and 3 mm thick inserted in position confirmed to design.
24
-
-
M & L for walling of random rubble, uncoursed well bounded bedded and solidly hearted, built in CM (1:6) including provision of weep holes complete all as specified and directed.
99
-
-
All as per ser No 39 here-in-before but except stones
5
-
-
M&L for raised pointing to random or polygonal rubble uncoursed or brought up to course in CM (1:4) complete all as specified and directed.
6
-
-
Mild steel TMT round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips including two coat of bituminous paint.
1170
-
-
TMT Steel bars 6 to 8mm dia, cut to length bent to shape required including cranking bending spirally or hopping for columns hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified.
80
-
-
All same as per item No 43 above but 5mm dia.
450
-
-
Cutting into existing manhole/soakwell/septic tank making good to pipe and benching cutting out existing benching for and forming branch channel (half round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required for internal dia size 150mm.
2
-
-
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
33
-
-
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter.
68
-
-
Use and waste of formwork to sides of pillars posts, struts, piers, columns and stanchions finished the suface rough.
67
-
-
Use and waste of formwork to sides and soffits of floors or roof beams, beams haunchings, girders,bressummers lintels, cantilevers, shelves including supports overhangs etc also splays between floors and beams etc.
31.3
-
-
Use and waste of formwork to chajjas, troughts and similar items including edges.
5.5
-
-
M&L for RCC Nominal Mix Type B1 1:2:4 (using 20 mm graded stone aggregate) as in foundation, including rafts, footings, foundation beams; plinth beams; bases for coloumns, etc basement slabs under reamed piles and mass concrete.
11.2
-
-
M&L for RCC Nominal Mix Type B1 1:2:4 (using 20 mm graded stone aggregate)as in columns, pillars, piers, posts and struts.
4.2
-
-
M&L for RCC Nominal Mix Type B1 1:2:4 (using 20 mm graded stone aggregate) slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like.
2.3
-
-
M&L for RCC Nominal Mix Type B1 1:2:4 (using 20 mm graded stone aggregate) as in chajjas.
0.82
-
-
M&L for RCC Nominal Mix Type B1 1:2:4 (using 20 mm graded stone aggregate) as in beams, cantilvers, bressummers, lintels over 1.5m span.
3.12
-
-
S&F for steel work in tabular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to I.S.1161-1998 grade St- 240 all as specified and directed.
2127
-
-
S&F for post of Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) confirming Fe 410 -W (Gde- E- 250) quality- A
188
-
-
Roof trusses (framed), trussed, purlins, crane gantries, rails,posts and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc
420
-
-
S&F MS plate 6mm thick (Plain or chequred) ,channels, and counter sank forming holes, with out any attachment FE-410-W (Code E - 250) Quality - B
10
-
-
S&F mild steel framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290 Gde E-165.
95
-
-
S&F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 complete all as specified and directed.
24
-
-
Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe290 Gde-E-165.
98
-
-
Mild steel, plain black sheet 1mm thick in wall cladding, steel gates and similar work, cut to size holes punched, including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams all as specified and as directed.
5.2
-
-
S&F steel windows with side hung shutters including Box type hinges with steel handle and steel peg stay, complete with glazing bars, devetailed or welded.
7.9
-
-
S&F 3mm thick figured glass, pin head type and glazing with oil putty in squares n.exc 0.5 Sq.m in each pane.
6.5
-
-
M&L of sand filling under floor well ramming including watering as required Spreading & leveling in layers n.exc. 25cm thick
19.85
-
-
M&L, providing Kota stone slab 20 to 25mm thick machine cut and mirror polished to size and fixed in floor and set and jointed in neat cement slurry and pointed with grey cement to match the stone floor/steps treads over 15mm thick screed bed in CM 1:6 complete all as specified and directed.
83
-
-
M&L, providing Kota stone slab 20 to 25mm thick machine cut and mirror polished to size and fixed in wall and set and jointed in neat cement slurry and pointed with grey cement to match the stone over and including 10 mm thick rendering in CM 1:4 for laying in vertical surfaces complete all as specified and directed.
5.7
-
-
M/L for factory made 80 mm thick precast cement concrete interlocking tile paver blocks of grade M-40 of size and shape as directed such as I-shape , Uni, Octagonal, Three-X, Dumble , zig, zaj etc , laid over and incl 50 mm thick sand custion (local Tibba sand ), laid dry , joints filled with dry sand complete all as specified and directed by EIC (Note : sand will be measured separetly).
75
-
-
S&F Plates (plain or chequered) channels. Square cut or notched ) (ordinary and counter sunk) forming holes, without any attachment of Fe-410-W (Gde-E-250 quality-A)
45
-
-
S&F bands, straps or stays , plain angle cleat or flat iron cleat or securing purlins to wood trusses or rafters, knee piece and similar small articles etc conforming to Fe-290 Gde E-165.
12
-
-
S&F PVC (SWR) 110mm dia junction single T equal or un equalwith an floor
2
-
-
S&F PVC (SWR) 110mm dia bends in any radius.
2
-
-
S&F PVC (SWR) 75mm dia single socketed in any length with rubber ring joints laid in trenches or in floor.
5
-
-
S&F PVC (SWR) 75mm dia vent cowl
2
-
-
S&F for 110 mm dia PVC (SWR) pipe single socketed in any length with rubber joints laid in trenches/floor/weep holes and similar work all as specified.
182
-
-
M&L for preparation of new plastered surfaces and applying three coats of white wash on walls all as specified & directed by Engineer-in-Charge
125
-
-
M&L for preparation of new wall surface and two coats of cement base paint on walls.
135
-
-
M&L for preparation of new ceiling surface and two coats of cement base paint on ceiling.
5
-
-
M&L for preparation of new steel surfaces of any description not other wise described over 10 cm width or girth and applying two coats of synthetic enamel paints over one of red oxide primer all as specified as directed.
123
-
-
M&L for Point wiring complete with two runs of 1.5 sqmm single core PVC insulated FR-LSH cable 1100 volts grade with multi-stranded copper conductors, drawn through and including PVC double locked Casing & caping including provision of 1.5 sqmm, FR-LSH, PVC insulated copper cable as earth continuity conductor connecting to earth dolly, including PVC rectangular box for mounting switches/sockets/regulators etc. with 3mm thick plastic laminated sheet cover of suitable size as required at site and 50 mm deep complete all as specified and as directed.Make:- Finolex/Richa/RR Kabel Make of caping/casing & PVC boxes :- Prestoplast/Finolex/supreme/RichaMake: finolex/Havells/RR Kabel. Make of caping/casing & PVC boxes: Prestoplast/finolex/Supreme.
1
-
-
One light/fan point controlled by one, one way switch.
3
-
-
One light point/fan point controlled one way each addition light point on the same switch circuit
15
-
-
One 3 pin socket outlet 5 Amps on the independent board.
2
-
-
All as per item No.81 here-in-before but with 2.5 Sqmm for 3 pin 15 Amps switch socket point on independent board along with one run of 2.5 Sqmm copper conductor green in colour as earth continuity conductor connected to earth dolly complete all as specified and as directed.
1
-
-
M&L for Switch Piano, flush type single pole, one way 5 Amps complete all as specified and directed. Make:-Anchor/Plaza/SSK
20
-
-
M&L for Socket outlet 2 in 1, 3 pin, 5A flush type complete all as specified and directed.
Make :Anchor/Plaza/SSK
2
-
-
M&L for Switch Socket combination 2 in 1, 3 pin 5A/16A, 5 in 1 flush complete all as specified and directed. Make :Anchor/Plaza/SSK
1
-
-
M&L for stepped type electronic fan regulator 100 watt socket size flush type on the existing phenolic laminatied sheet etc. Make :Anchor/Plaza/SSK
4
-
-
M&L for ceiling rose 3 terminal PVC/ Polycarbonate isolated body with PVC round/squareblock complete all as specified and directed.
Make :Anchor/Plaza/SSK
14
-
-
M&L for 20W LED, 4', Wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver.etc with all accessories internally pre-wired and fixing the same on and including two Nos PVC blocks and connecting up with flexible copper cable of size 0.75 Sq mm 3 core from ceiling rose to the light fitting complete all as specified and as directed.
Make : Havells Cat No LHFYBYPNIA1W022(batten) & LHLDDCXCML8P020(LED Tube) or equivalent in Bajaj/Philips Make : Havells Cat No LHFYBYPNIA1W022 Regal (batten) & LHDLEFXD5LR020(LED Tube) or equivalent in Bajaj/Philips
6
-
-
M&L for Lamp holder , PVC/ Polycarbonate type with PVC round/square block incl 9 watt LED lamp suitable for lamp holder fittings. Make :- Plaza/SSK/Anchor Make of Lamp :- Havells/Bajaj/Philips
4
-
-
M&L for LED 1x20W building Security light fitting, drawn through including GI bracket of 25mm bore light grade bent to shape and fixed on wall with metal fastners 2 Nos 10mm dia incl drilling holes as required and connecting up with flexible copper cable of size 0.75 Sq mm 3 core from ceiling rose to the light fitting complete all as specified and directed. Make:-Endurapearl SL20WLLED757SASYTOPCMP /Bajaj/Philips/CGMake:-Havells Cat Pt No LHETBXU7PA6S020 or equivalent in Bajaj/Philips
2
-
-
S&F for Ceiling fan 1200 mm sweep, 5 star rating including suitable size of fan hook and connecting up with three core twisted flexible copper conductor cable of suitable size upto ceiling rose complete all as specified and as directed.
Make : Usha/Bajaj/CG
4
-
-
S&F for fixing Exhaust fan, Metallic, AC single phase 230/ 240 volts of size 300 mm sweep with louvre shutter including anchor bolt of suitable size for fixing arrangement and connecting up with three core twisted flexible copper conductor cable of suitable size upto ceiling rose complete all as specified and as directed.
Make : Bajaj/CG/Havells
2
-
-
M&L for MCB Distribution board double door type SPN 8 way, sheet steel, powder coated, with bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity complete all as specified and as directed. Make:- Legrand Cat No 507711 or equivalent in ABB/Siemens
1
-
-
M&L for MCB SPN, 40 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB 'C' series incl taking down complete all as specified and as directed. Make: Legrand Cat No 408636 or equivalent in ABB/Siemens.
1
-
-
M&L for MCB SP, 5 to 32 Amps, 415 volts, 50 Hz suitable for fixing in MCB DB 'C' series complete all as specified and as directed. Make:- Legrand Cat No 408587-95 or equivalent in ABB/Siemens
6
-
-
Taking down LT UG cable/service connection of any size and M&L for laying of LT UG cable , XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 10 sq mm, 2 core complete all as specified and as directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items. Make: Richa/Polycab/Phinolex
30
-
-
M&L for fine river washed sand in trenches complete all as specified ans as directed. NOTE: For measurement purpose, punned down thickness shall only be taken.
1.35
-
-
M&L for laying brick sub class 'B' old size burnt bricks for cable protection of size 230mmx115mmx75mm complete all as specified and as directed
173.91
-
-
Supply and laying tubes light grade galvanised GI tubing with all fittings, fixed complete to walls/poles/laid in floors/trenchs/road crossing of size 40mm dia bore including taking out unsv GI tubing complete all as specified and as directed. Make: Jindal/Prakash surya/TATA
6
-
-
M&L for earthing complete with galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4 mm dia as earth lead connectd by means of bolts, nuts, washers and check nuts all as shown in electrical plate No 3 of MES SSR Part-I, including testing on completion complete all as specified and as directed.
(i) The unit rate shall also included for earth work in hard/ dense soil, PCC (1:3:6) type C1 with 10mm thick CI cover plate hinged to angle iron frame of suitable size, funnel with GI watering pipe 20mm dia Medium grade, GI protection pipe light grade 15mm dia and wire mesh complete in addition to item No 1 (a) to (e) of preamble (notes) under sub heading earthing, specified on Sl Page No 389 of MES SSR Part-II. (ii) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately. (iii) Test points shall be made of GI strip 32x6 mm bridge type.
1
-
-