Assam Rifles Tender
View complete overview of Nagaland Assam Rifles Tender
Costs
EMD
₹ 4,07,000Document Cost
₹ 1,500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_ARMHA_775461_1Bid Award Id
ViewTender No
11014/7934/ARTCS/ENGR/SRW2023Tender Authority
Assam Rifles ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
NIT for Spl repair to existing water treatment plant , 1 x 250 KVA generator and IPR for ARTC
BOQ for Spl repair to existing water treatment plant , 1 x 250 KVA generator and IPR for ARTC
BOQ Items
Supply and fixing GI flange suitable for fitting the pipes including nut bolts and gaskets complete 100 / 80 mm bore.
50
-
-
Supply and fix Class-I valves, sluice, flanged of class IPN 16 100mm (4”) dia class-II.
20
-
-
SCHEDULE ‘A’ PART- II ( SPECIAl REPAIR TO POWER HOUSE INCLUDING 1 x 250 KVA GENERATOR SET AT DIMAPUR AGAINST BER AND REPLACEMENT OF INCOMMING FEEDER PANEL, WIRING, RISING MAIN ALLIED SERVICE (FEEDER PILLAR BOXES) AT VARIOUS POCKETS AT ARTC&S). Dismantling and taking out old UNSV panel board from Genr Room incl disconnecting of feeders from DG set and depsoited to sotre yard of ARTC.
1
-
-
Supply, Installation,testing and commissioning complete 800 Amps DG Set panel board made out of 2mm thick CRCA sheet steel , out door front facia, powder coated for long lasting finish cubical type suitable cable entry provision including of all necessary electrical portection including aluminum busbar comprising the following :- (Panel Size: 2.7 Mtr (l) x2.1mtr (ht)x0.60 mm width) (a) Change over siwtch 4 Pole ,400 Amps -02 Pcs (Make :SIEMENS/L&T/SCHNEIDER). (b) MCCB 4 pole, 50 KA 800 Amps Breaking capacity with fixed type thermal magnetic protection complete including spreader link , extended rotary handle , phase indicating lamps,MCB SP16 Amps for control protection including Digital multifunction meter complete with CT coil with roarty handle and phase incator complete - 01 Nos (MCCB: SIEMENS/L&T/SCHNEIDER) (c) MCCB 4 pole, 35 KA 400 Amps Breaking capacity with fixed type thermal magnetic protection complete including spreader link , extended rotary handle , phase indicating lamps,MCB SP16 Amps for control protection including Digital multifunction meter complete - 02Nos (MCCB: SIEMENS/L&T/SCHNEIDER) (d) MCCB 4 pole, 35 KA 200 Amps Breaking capacity with fixed type thermal magnetic protection complete including spreader link , extended rotary handle , phase indicating lamps,MCB SP16 Amps for control protection including Digital multifunction meter complete - 04 Nos (MCCB: SIEMENS/L&T/SCHNEIDER) (e) MCCB 4 pole, 35 KA, 100 Amps Breaking capacity with fixed type thermal magnetic protection complete including spreader link , extended rotary handle , phase indicating lamps,MCB SP16 Amps for control protection including Digital multifunction meter complete - 03 Nos Load Bearing member will be Fabricated from 2 mm thick CRCA MS sheets, Inside partitions are made with 1.6mm CRCA MS sheet steel and Cable Gland plate with 3mm CRCA MS Sheet steel. The panel shall have wall and floor grouting system. The panel shall have minimum 200 mm bottom stand (if necessary for bottom cable entry). The panel operation height shall not exceed 1800 mm. structural reinforcement with suitable angle/channel/T/flat sections including lifting hooks and GI earth strip of required size with 2 nos earthing terminals. Painting :- Powder coated paint finish of approved shade over metal surface cleaned and treated with all anticorrosive process and seven tank process before painting, with 2 coats of zinc chromate primer upto 75 micron thickness and colour RAL7035 of enameled paint as per as per specifications.. Labeling:- All Panels shall be duly metal labeled with scheme diagram and Danger mark with 415V AC operation.Cable Entry:- The panel shall have a provision of cable entry at the bottom and top as per site requirement. Busbar:- Busbar shall be sized with current density of Amperage 1A/sq.mm for Aluminum Busbars .Heat Shrinkable Color Coded PVC Sleeves for all Busbars, minimum bus bar gap of 32mm shall be maintained, busbar shall be of E91E Grade for Al.. MCB Connectivity:-MCB shall be connected using FR cables of proper rating from Vertical busbars.
1
-
-
Excavating trenches of required width for pipes, cables, etc, includingexcavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming,watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 400 Sqmm size.
600
-
-
M/L disnmantling and taking out UNSV XLPE cable from exisitng connection for replacement for replacment upto 240 Sqmm cable complete.
600
-
-
Supply and laying one number PVC insulated and PVC sheathed / XLPEpower cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required of size 95 Sqmm .(make: Havells/Gloster/Polycab/KEI).
500
-
-
Supply and laying one number PVC insulated and PVC sheathed / XLPEpower cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required of size 120 Sqmm. (make: Havells/Gloster/Polycab/KEI).
1000
-
-
Supply and laying one number PVC insulated and PVC sheathed / XLPEpower cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required of size 400 Sqmm. (make: Havells/Gloster/Polycab/KEI)
100
-
-
Erection of ACSR conductor of 7/2.11 mm to 7/3.00 mmdiameter including binding etc. as required including taking down from exisitng steel poles.
700
-
-
Erection of galvanised 'D' iron clamps and insulator on pole as requiredincluding taking down from exisitng steel poles.
233
-
-
Supply and fix LT OH lines on existing poles with ACSR conductors3 of 6/1 x 2.59 mm (Weasel),1 of 6/1 x 2.11mm (Squirrel)
500
-
-
Supply and installation of silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, engine as per IS:10001/ 10002 and Alternator as per IS: 13364 complete with relay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms and foundation etc. of capacity upto 250 KVA capacity.The DG set comprises of KOEL Green Engine at 1500 rpm complying with the requirements of BS5514/ IS 10002, directly coupled to a KOEL Green AC generator capable of 50 Hz, 0.8pf (lag) generally meeting the requirements of BS5000 AT 230/415Volt. A power control panel to regulate the AC power is also provided. The sheet steel cubicle type Control Panel is floor standing, dust & vermin proof under normal conditions. It will be complete with all internal wiring camplete as per OEM instructions. (Make: KOEL/Mahindra)
1
-
-
Supply and fix steel tubular swaged poles type 410 SP-31 (9 meter long) complete with CI base plate and finial including foundation and coping
12
-
-
Earthing of machinery/equipment Installed at power house/substation, using 32 x 6 mm galvanized GI strip and galvanized plate of size 600 x 600 x 6 mm ,as earth electrode (Set of 02)
5
-
-
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
50
-
-
SCHEDULE ‘A’ PART- III SPECIAL REPAIR TO EXISTING DISTRIBUTION SYSTEM SERVICE TANKS, VALVES, PUMP HOUSE BUILDING, 01 x IRP RENOVATION AND ALLIED SERVICES FOR ARTC&S AT DIMAPUR. Supply,Installation,testing and commissioning of SMC panel tank of size 10x10x2mtr size with bottom panel 1x1 mtr, side panel 1x2xmtr , Roof panel 1x1mtr with corner L assembly of SMC/Equivalent with accessories made up of PVC/HDP (Hard Dip Galvanised) with following provisions, PVC Air Vent , FRP internal ladder FRP external ladder and scaling facilities including following connected works :- (a) Dismantling and taking out UNSV PS Tank and deposition of material upto storeyard. (b) Reshuffle the previous ISMB 125 across the same. (c) Detailed drawing from SINTEX/OEM will be submitted to this office for acceptance
1
-
-
M & L for dismantling of existing 10000 GPH Pressure filter including removal of existing old filter media of various sizes , unserviceable strainers etc and deposited to place where directed complete :- (a) Cleaning the surfaces of Pressure Filter and all accesses with emery paper, preparing the surfaces and painting with two coats of synthetic enamel paint over a coat of red oxide primer on outer surfaces and two coat of black bituminous paint on inner surfaces of IRP of capacity 10000 GPH all as specified and directed.
(b) Supply and fill treated barker sand of 16/32 mm size and Gravel of size 1", 3/4", 1/2", 3/8", 1/4", 1/8" -185 Cft (c) Supply and fixing rubber gasket joint for all packing required places of IRP unit - 01 Job (d) Supply and replacement of plastic strainer (push Type) of approved quality and size as existing all as specified and directed of 450 Nos (e) Replacement of existing MNO2/anthratite from oxidation chamber with new MNO2 lumps to be used as oxidizing agent - 34 Cft (f) Supply and fix diaphragm valves/sluice cast iron angular type of size 80 mm dia -03 Nos (g) Supply and fix water pressure gauge duly calibrated of existing size complete 02 Nos all as specified and directed.
(h) Necessary water report as per IS-10500 will be submitted to this office after completion.
1
-
-
Supply and fix Valves, Sluice, flanged of class 1.6 PN 80 mm (3”) dia.
10
-
-
Supply and fix Valves, Sluice, flanged of class 1.6 PN 100 mm (4”) dia.
10
-
-
Supply and lay pipe galvanized, “Heavy class”, including fittings 100 mm (4”) dia.
500
-
-
Providing and fixing G.I. pipes complete with G.I. fittings includingtrenching and refilling etc of 80 mm dia.
500
-
-
Supply and fixing GI flange 100 mm suitable for fitting the pipes including nut bolts and gaskets complete
50
-
-
Repair to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under incl cutting the patch in proper shape, racking out joints and plastering the surface of the walls etc complete with CM (1:4) mix.
100
-
-
Distempering one coat with acrylic distemper on old surface of approved brand and manufacturer to given an even shade, incl removal of old distemper by scraping and preparing surface smooth and necessary repair to scratches etc complete.
250
-
-
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
250
-
-
Providing and Painting synthetic enamel paint one or more coats with synthetic enamel paint of approved brand and manufacture to give an even shade.
20
-
-
Making Plinth protection 50 mm thick of cement concrete 1:3:6 over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
13.75
-
-
Demolishing cement concrete 1:3:6 or richer mix (i/c equivalent design mix) manually/ by mechanical means including disposal of materials within 50 m lead as per direction of Engineer – In – Charge.
1.88
-
-
Providing and laying of ceramic glazed wall tiles of approved make in all colours of any size in walls/skirting over 12 mm thick bed of CM (1:3) and jointing with grey cement slurry @ 3.3 kg per sqm incl pointing the joints with white cement complete.
12
-
-
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests.
1
-
-
Providing and laying vitrified floor tiles (size 600x600 mm), laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments. etc. complete.
46.82
-
-
Providing and fixing flush door shutter non decorative type, core block board of 35 mm thick incl stainless steel butt hinges etc complete.
4.68
-
-
Providing and fixing 35 mm thick wire gauge shutters using stainless steel grade 304 wire gauge with wire of wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors and windows with kiln seasoned and chemically treated teak wood.
3.12
-
-
Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.50 mm with 2nd class teak wood beading 62x19 mm all complete.
3.12
-
-
Finishing wall with water proofing cement paint of required shade on old work (one or more coats on existing cement paint surface applied).
200
-
-
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
30
-
-
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
25
-
-
Supplying and fixing following piano type switch/ socket 5 Amps on the existing switch box/ cover including connections etc. as required.
5
-
-
Supplying and fixing following piano type switch/ socket 15 Amps on the existing switch box/ cover including connections etc. as required.
4
-
-
Supplying and fixing brass batten/ angle holder includingconnection etc. as required.
5
-
-
Supply & fix fans ceiling complete with electronic type regulator and accessories 230 V,1200 mm sweep. BEE 5 star rated (Make : BAJAJ/ORIENT/LUMINUOUS)
3
-
-
Earthing of machinery/equipment Installed at power house/substation, using 25 x 3 mm copper strip and copper plate of size 300 x 300 x 3 mm, as earth electrode.
3
-
-
M/L replacement of 1000 LPH Membrane, Micron cartiges incl accessoires complete
1
-
-
SCHEDULE 'A' PART XI : SCH OF CREDIT. Unsv G.I. Pipe (80 to 100 mm bore (It is necessary to quote at least Rs. 100/- per Rm or more)
4000
-
-
Unsv panel board for 800 Amp (It is necessary to quote at least Rs. 5000/- per Nos or more)
1
-
-
Unsv U/G Cable 240 sqmm 3 1/2 core alumn (It is necessary to quote at least Rs. 50/- per Rm or more)
600
-
-
Unsv Generator Set 250 KVA with altanator (It is necessary to quote at least Rs. 1,40,000/- per Kgs or more)
1
-
-
Unsv PS water (w/o storage) (It is necessary to quote at least Rs. 1,00,000/- per Nos or more)
1
-
-
Unsv 80mm G. I. Pipe (It is necessary to quote at least Rs. 50/- per Meter or more)
1000
-
-
Retrived items for Rewiring (It is necessary to quote at least Rs. 10/- per Point or more)
25
-
-
Retrived items for Rewiring (It is necessary to quote at least Rs. 100/- per Set or more)
6
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements