Rural Development Department Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Rural Development Department - RDD Tender

Works
Civil And Construction
Eprocure
Opening Date29 Nov 2024
Closing Date9 Dec 2024
Tender Amount₹ 6,61,76,047 
Notes
Download

Costs

  • EMD

    ₹ 3,30,865
  • Document Cost

    ₹ 17,700
  • Tender Fee

    ₹ 500

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Cutting of trees, including cutting of trunks, branches and removal of stumps & roots, refilling, compaction of backfilling and stacking of serviceable material by manual means with all lifts as per Technical Specification Clause 201.. Girth above 300 mm to 600 mm

3

426

1280.43

... More
Cutting of trees, including cutting of trunks, branches and removal of stumps & roots, refilling, compaction of backfilling and stacking of serviceable material by manual means with all lifts as per Technical Specification Clause 201.. Girth above 600 mm to 900 mm

2

681

1363.12

... More
Loosening, Levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per Technical Specification Clause 301.4.1.

3315

27

92289.6

... More
Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead upto 1000 m as per Technical Specification Clause 302.3

14339.38

55

802861.89

... More
Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead upto 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Clause 302.3.5

5619.71

85

481889.96

... More
Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and croun-sections, loading and disposal of cut rock with a lift upto 1.5 m and with all leads as per Technical Specification MORD 2014 Clause 302.3.5

624.41

95

59831.16

... More
Excavation in Hard Rock (blasting Prohibited) -Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 metre and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5

7805.15

375

2930287.46

... More
Excavation for roadway in hard rock with controlled blasting by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 m and leads upto 1000 m as per Technical Specification Clause 302.3.5

3122.06

158

494627.97

... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5

18685.53

72

1348347.84

... More
Construction of Granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. For Grading II material by mix in Place Method

1100.26

2243

2468397.82

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, Stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density WBM Grading 2 as per Technical Specification Clause 405. For - By Mechanical Means

596.7

2675

1596330.03

... More
Modified Penetration Macadam- Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506.(50 mm thick Bitumen (S-65) Material As per MORD specification no. 506)

7956

220

1755581.9

... More
20mm thick Open-Graded Premix Carpet using S 65 (penetration grade/modified bitumen) Binder Bitumen(S-65) 60/70- (VG 30)-Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades. to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508 . Case - II By Mechanical Means, Bitumen(S-65) - (VG 30)

7956

143

1139927.45

... More
Tack Coat -Providing and applying tack coat with Bitumen emulsion (Rapid Setting-1) using emulsion distributor at the rate of 0.20 to 0.25 kilogram per square meter on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503

7956

11

92903.62

... More
Seal Coat-Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A , Type B (by Paver finisher) and Type C as per Technical Specification Clause 510

7956

67

533621.67

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil By Mechanical means

766.94

532

408265.17

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 m depth

181.09

567

102754.09

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard rock (requiring blasting)

399.27

933

372642.68

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard rock (Blasting Prohabited)

149.25

854

127546.07

... More
Removing all types of Hume pipes and stackig within a lead of 1000 m including Earthwork and Dismantling of Masonry work as per Technical Specification clause 202- Upto 600 mm Diameter. Hume pipe

18

345

6218.82

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802,803, 1202 & 1203 P.C.C grade M 10 Nominal mix (1:3:6)

698.54

5939

4149304.45

... More
Plain/reinforced cement concrete in sub structure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 - P.C.C grade M 15 Nominal mix (1:2.5:5)

651.13

6258

4075234.42

... More
Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.600 mm Diametermeter

30

2733

81990

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.1000 mm Daimeter

157.5

7069

1113406.88

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.1200 mm Daimeter

22.5

9373

210900.15

... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5. II. R.C.C M 25

150.98

7414

1119400.67

... More
Providing and laying cement concrete wearing course M 30 grade Excluding reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3

16.76

12351

207016.96

... More
Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202

12.72

64291

817789.13

... More
Providing weepholes in brick masonry / stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm Diameter AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification MORD 2014 Clauses 614, 709, 1204.3.7 A.C. pipe 100 mm Diametermeter

212.5

181

38519.88

... More
Providing Tar paper bearing of approved quality in proper size etc. complete (Rate as per PWD CSR 2020-21) BR Item no.13.02 Pg no 118

33.3

99

3296.7

... More
Drainage spouts complete as per drawing and technical specifications Clause 1209

32

1563

50018.24

... More
Expansion joint with 25 mm thich bitumenous pad / Compressible Rubber Pad (Rate as per PWD CSR for 2018-19) BR 43B Item no.14.33 pg no.123

25.74

1086

27953.64

... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8

44.92

1901

85415.69

... More
Dewatering including diversion of streame providing coffer dam bunds etc as may be necessary for foundation and other parts of the work and bailling out water during and after excavation required For Abutment

233.64

145

33924.53

... More
Dewatering including diversion of streame providing coffer dam bunds etc as may be necessary for foundation and other parts of the work and bailling out water during and after excavation required For Pier

92.5

698

64602

... More
Dewatering including diversion of streame providing coffer dam bunds etc as may be necessary for foundation and other parts of the work and bailling out water during and after excavation required For Return

159.12

67

10692.86

... More
Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 1701

450

1

659.03

... More
Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015).

364

666

242424

... More
"Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15 cm wide strips, fitted with 80x100mm rectangular or 75mm Diametermeter. Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings"

50

822

41100

... More
Retroreflective tape (Engg Gr.)

40

1050

42000

... More
Ordinary Kilometer Stone (Precast) - Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703

4

2528

10112.28

... More
200 m stone (precast) - Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703

12

524

6289.92

... More
Boundary Pillar / Guard Stone-Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704

260

598

155534.6

... More
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered/concrete surfaces as per drawing and Technical Specification Clause 1701

182.09

143

26165.61

... More
Providing and fixing Retro Reflective MMGSY/PMGSY LOGO informatory sign board with Logo as per section 1700 of MORD specification sand latest PMGSY Signage Manual/Circuler and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3mm ACP in Diametermetermond shape of 600x600 mm size, rivete dwith MS angle ironframe of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle ironframe of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat ironframe will be done neatly to have plain surface on one side. The angle ironframe of Both the plates will be welded to a 75mmx75mmx12 swg Mild steel post at/Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200 mm from normal ground level. The spacing between the Diametermetermond shaped plate and Lower Plate is kept 150mm. MMGSY/PMGSY logo, letters and numeral sonthe ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo MMGSY Logo Project description on ClassA or ClassB type retroreflective sheeting using modern technology printing plat form. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The in k sused for printing shall be ecofriendly with VOC emissions complying to UL2801 standards and specifications for the different kinds of plat forms. The printe dsign shall be laminated by UV protected laminate and shall carry awarranty of 5 years & 7 years for ClassA and ClassB sheeting respectively for traffic colors.” All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1(B) and as directed by Engineerin-charge. A warranty for 5/7 years for the Retroreflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.(SOR ITEM NO.10.16 ) A) Retro Reflective sheeting class-A

2

14759

29519.46

... More
MMGSY/PMGSY Citizen's information Board-Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specification sand latest PMGSY Sign age Manual/Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35x35x5mm thic kM. Sangle shall be welded by two vertical M.S angle of 5mm thick to 75mmx75mm of 12 SWG square tubes/75mm Diameter Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mmx600mmx75mm, below ground level . MMGSY/PMGSY logo, letter sand numer also n the ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade as per the latest MORD section1700 specifications (Refer Circuler no. NRRDA-P 013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo /MMGSY Logo/Project descriptionon ClassA or ClassB type retroreflective sheeting using modern technology printing platform. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The inks used for printing shall bee co friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of plat forms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed post sand steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed

3

28401

85203

... More
Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 600 mm equilateral triangular

16

2352

37638.4

... More
Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheeting c. 600 x 450 mm Rectangular

2

2352

4704.8

... More
Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 600 mm circular

2

2352

4704.8

... More
(Village Name Board) Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4 mmt hick ACP sheet supported with Back support frame of 35x35x5 mm mild steel angle with are as not exceeding 0.9 sqm. Supported in mild steel angle iron post 75x75x6mm-3.5mt rheight, firmly fixed to the ground by means of properly designed foundation of M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level complete (as per MoRT & H specification No.801) (for area Less than 0.9 sqm). 7 Both border & background shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product offered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. The reshall be as tamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.

1.8

3453

6216.55

... More
Supplying & Fixing of Molded Shank Raised Pavement Markers / Cat's Eye made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer's recommendation and complete as directed by the engineer.The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer.

150

366

54900

... More
Providing and fixing in position pipe railing consisting of IS Rolled steel joist posts designation IS MB 100 (100x50) at 2.5 m interval and three rows of 50 mm dia steel pipes (light) including fixing in position on bridge deck complete as per drawing and technical specifications Clause 1208.2

88

3042

267776.96

... More
Diversion for bridge at km

50

1483

74162.59

... More
Providing and laying 0.90 meter thick metal mat consisting of rubble, oversize metal and normal size metal in specified thickness as per detailed drawing including supplying all materials, hand packing of rubble, spreading metal in layers and hard murum including watering and compaction with power roller etc. complete.

112.56

1498

168688.04

... More
2.00 Upgradation & Maintanance of Ilane Waghivane Wanzloli Road ,Taluka-- Dapoli,District-Ratanagiri ch-0/000 TO 1/440 km. 3.00

-

-

-

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material By Mechanical Means- In area of Non-thorny jungle

0.35

29447

10306.77

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material By Mechanical Means- In area of thorny jungle

0.23

36254

8338.45

... More
Cutting of trees, including cutting of trunks, branches and removal of stumps & roots, refilling, compaction of backfilling and stacking of serviceable material by manual means with all lifts as per Technical Specification Clause 201.. Girth above 300 mm to 600 mm

3

426

1280.43

... More
Cutting of trees, including cutting of trunks, branches and removal of stumps & roots, refilling, compaction of backfilling and stacking of serviceable material by manual means with all lifts as per Technical Specification Clause 201.. Girth above 600 mm to 900 mm

2

681

1363.12

... More
Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead upto 1000 m as per Technical Specification Clause 302.3

9156.22

55

512656.57

... More
Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead upto 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Clause 302.3.5

2733.2

85

234371.81

... More
Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and croun-sections, loading and disposal of cut rock with a lift upto 1.5 m and with all leads as per Technical Specification MORD 2014 Clause 302.3.5

136.66

95

13094.76

... More
Excavation in Hard Rock (blasting Prohibited) -Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 metre and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5

1503.26

375

564368.7

... More
Excavation for roadway in hard rock with controlled blasting by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 m and leads upto 1000 m as per Technical Specification Clause 302.3.5

136.66

158

21651.04

... More
Excavation for roadway in hard rock with controlled blasting by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 m and leads upto 1000 m as per Technical Specification Clause 302.3.5

2415.38

72

174294.05

... More
Construction of subgrade and earthen shoulders with approved material obtained from Available Material with all lifts and leads, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.

1702.8

72

122874.05

... More
Construction of Granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. For Grading II material by mix in Place Method

669.89

2243

1502870.97

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, Stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density WBM Grading 2 as per Technical Specification Clause 405. For - By Mechanical Means

396.58

2675

1060945.5

... More
Modified Penetration Macadam- Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506.(50 mm thick Bitumen (S-65) Material As per MORD specification no. 506)

4406.4

220

972322.28

... More
20mm thick Open-Graded Premix Carpet using S 65 (penetration grade/modified bitumen) Binder Bitumen(S-65) 60/70- (VG 30)-Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades. to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508 . Case - II By Mechanical Means, Bitumen(S-65) - (VG 30)

4406.4

141

625044.11

... More
Tack Coat -Providing and applying tack coat with Bitumen emulsion (Rapid Setting-1) using emulsion distributor at the rate of 0.20 to 0.25 kilogram per square meter on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503

4406.4

11

51454.31

... More
Seal Coat-Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A , Type B (by Paver finisher) and Type C as per Technical Specification Clause 510

4406.4

67

295544.31

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil By Mechanical means

609.08

532

324231.56

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 m depth

52.17

567

29602.3

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard rock (requiring blasting)

165.69

933

154640.13

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard rock (Blasting Prohabited)

63.96

854

54658.94

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802,803, 1202 & 1203 P.C.C grade M 10 Nominal mix (1:3:6)

34.69

5939

206049

... More
Plain/reinforced cement concrete in sub structure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 - P.C.C grade M 15 Nominal mix (1:2.5:5)

708.09

6258

4431744.88

... More
Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.600 mm Diametermeter

22.5

2733

61492.5

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. 600 mm Diametermeter

30

4792

143760

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.1000 mm Daimeter

90

7069

636232.5

... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5. II. R.C.C M 25

72.37

7414

536579.13

... More
Providing and laying cement concrete wearing course M 30 grade Excluding reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3

5.79

12351

71517.2

... More
Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202

6.01

64291

386392.5

... More
Providing weepholes in brick masonry / stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm Diameter AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification MORD 2014 Clauses 614, 709, 1204.3.7 A.C. pipe 100 mm Diametermeter

241.5

181

43776.71

... More
Providing Tar paper bearing of approved quality in proper size etc. complete (Rate as per PWD CSR 2020-21) BR Item no.13.02 Pg no 118

23.4

99

2316.6

... More
Drainage spouts complete as per drawing and technical specifications Clause 1209

10

1563

15630.7

... More
Expansion joint with 25 mm thich bitumenous pad / Compressible Rubber Pad (Rate as per PWD CSR for 2018-19) BR 43B Item no.14.33 pg no.123

23.43

1086

25444.98

... More
Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less then 25 kg beyond curtain wall

25.01

1376

34414.87

... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8

69.78

1882

131373.41

... More
Dewatering including diversion of streame providing coffer dam bunds etc as may be necessary for foundation and other parts of the work and bailling out water during and after excavation required For Abutment

99.3

145

14418.36

... More
Dewatering including diversion of streame providing coffer dam bunds etc as may be necessary for foundation and other parts of the work and bailling out water during and after excavation required For Return

106.53

67

7158.82

... More
Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 1701

250

1

362.5

... More
Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015).

172.8

666

115084.8

... More
"Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15 cm wide strips, fitted with 80x100mm rectangular or 75mm Diametermeter. Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings"

25

830

20755.5

... More
Retroreflective tape (Engg Gr.)

25

1060

26512.5

... More
Ordinary Kilometer Stone (Precast) - Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703

4

2528

10112.28

... More
200 m stone (precast) - Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703

12

524

6289.92

... More
Boundary Pillar / Guard Stone-Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704

144

598

86142.24

... More
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered/concrete surfaces as per drawing and Technical Specification Clause 1701

100.14

143

14389.77

... More
Providing and fixing Retro Reflective MMGSY/PMGSY LOGO informatory sign board with Logo as per section 1700 of MORD specification sand latest PMGSY Signage Manual/Circuler and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3mm ACP in Diametermetermond shape of 600x600 mm size, rivete dwith MS angle ironframe of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle ironframe of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat ironframe will be done neatly to have plain surface on one side. The angle ironframe of Both the plates will be welded to a 75mmx75mmx12 swg Mild steel post at/Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200 mm from normal ground level. The spacing between the Diametermetermond shaped plate and Lower Plate is kept 150mm. MMGSY/PMGSY logo, letters and numeral sonthe ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo MMGSY Logo Project description on ClassA or ClassB type retroreflective sheeting using modern technology printing plat form. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The in k sused for printing shall be ecofriendly with VOC emissions complying to UL2801 standards and specifications for the different kinds of plat forms. The printe dsign shall be laminated by UV protected laminate and shall carry awarranty of 5 years & 7 years for ClassA and ClassB sheeting respectively for traffic colors.” All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1(B) and as directed by Engineerin-charge. A warranty for 5/7 years for the Retroreflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.(SOR ITEM NO.10.16 ) A) Retro Reflective sheeting class-A

2

14759

29519.46

... More
MMGSY/PMGSY Citizen's information Board-Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specification sand latest PMGSY Sign age Manual/Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35x35x5mm thic kM. Sangle shall be welded by two vertical M.S angle of 5mm thick to 75mmx75mm of 12 SWG square tubes/75mm Diameter Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mmx600mmx75mm, below ground level . MMGSY/PMGSY logo, letter sand numer also n the ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade as per the latest MORD section1700 specifications (Refer Circuler no. NRRDA-P 013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo /MMGSY Logo/Project descriptionon ClassA or ClassB type retroreflective sheeting using modern technology printing platform. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The inks used for printing shall bee co friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of plat forms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed post sand steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed

3

28401

85203

... More
Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 600 mm equilateral triangular

16

2352

37638.4

... More
Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheeting c. 600 x 450 mm Rectangular

2

2352

4704.8

... More
Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 600 mm circular

2

2352

4704.8

... More
(Village Name Board) Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4 mmt hick ACP sheet supported with Back support frame of 35x35x5 mm mild steel angle with are as not exceeding 0.9 sqm. Supported in mild steel angle iron post 75x75x6mm-3.5mt rheight, firmly fixed to the ground by means of properly designed foundation of M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level complete (as per MoRT & H specification No.801) (for area Less than 0.9 sqm). 7 Both border & background shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product offered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. The reshall be as tamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.

1.8

3453

6216.55

... More
Providing and fixing in position pipe railing consisting of IS Rolled steel joist posts designation IS MB 100 (100x50) at 2.5 m interval and three rows of 50 mm dia steel pipes (light) including fixing in position on bridge deck complete as per drawing and technical specifications Clause 1208.2

20

3042

60858.4

... More
3.00 Upgradation & Maintanance of M.D.R-15 to Nayane Aatle Baudhwadi Road ,Taluka-- Mandangad,District-Ratanagiri ch-0/000 TO 2/800

-

-

-

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material By Mechanical Means- In area of Non-thorny jungle

0.67

29447

19730.1

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material By Mechanical Means- In area of thorny jungle

0.45

36254

16314.35

... More
Cutting of trees, including cutting of trunks, branches and removal of stumps & roots, refilling, compaction of backfilling and stacking of serviceable material by manual means with all lifts as per Technical Specification Clause 201.. Girth above 300 mm to 600 mm

3

426

1280.43

... More
Cutting of trees, including cutting of trunks, branches and removal of stumps & roots, refilling, compaction of backfilling and stacking of serviceable material by manual means with all lifts as per Technical Specification Clause 201.. Girth above 600 mm to 900 mm

2

681

1363.12

... More
Loosening, Levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per Technical Specification Clause 301.4.1.

378

27

10523.52

... More
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202.Rubble Stone Masonry in Cement Mortar

100.36

188

18947.97

... More
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. Cement Concrete

31.53

750

23662.32

... More
Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead upto 1000 m as per Technical Specification Clause 302.3

2603.62

55

145776.73

... More
Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead upto 1000 m as per Technical Specification Clause 302.3

564

532

300234.12

... More
Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead upto 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Clause 302.3.5

1205.38

85

103361.34

... More
Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and croun-sections, loading and disposal of cut rock with a lift upto 1.5 m and with all leads as per Technical Specification MORD 2014 Clause 302.3.5

241.08

86

20737.36

... More
Excavation in Hard Rock (blasting Prohibited) -Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 metre and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5

723.23

369

267078.19

... More
Excavation for roadway in hard rock with controlled blasting by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 m and leads upto 1000 m as per Technical Specification Clause 302.3.5

48.22

148

7166.23

... More
Excavation for roadway in hard rock with controlled blasting by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 m and leads upto 1000 m as per Technical Specification Clause 302.3.5

3047.2

72

219886

... More
Construction of subgrade and earthen shoulders with approved material obtained from Available Material with all lifts and leads, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.

690.19

72

49804.11

... More
Construction of Granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. For Grading II material by mix in Place Method

433.54

2224

964591.33

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, Stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density WBM Grading 2 as per Technical Specification Clause 405. For - By Mechanical Means

179.01

2642

473051.47

... More
Modified Penetration Macadam- Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506.(50 mm thick Bitumen (S-65) Material As per MORD specification no. 506)

5871

235

1382923.5

... More
20mm thick Open-Graded Premix Carpet using S 65 (penetration grade/modified bitumen) Binder Bitumen(S-65) 60/70- (VG 30)-Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades. to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508 . Case - II By Mechanical Means, Bitumen(S-65) - (VG 30)

5871

142

836136.44

... More
Tack Coat -Providing and applying tack coat with Bitumen emulsion (Rapid Setting-1) using emulsion distributor at the rate of 0.20 to 0.25 kilogram per square meter on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503

5871

11

68201.23

... More
Seal Coat-Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A , Type B (by Paver finisher) and Type C as per Technical Specification Clause 510

5871

66

391249.98

... More
Construction of dry lean cement concrete Sub-Base over a prepared Sub-grade with coarse and fine aggregate conforming to IS:383,the size of coarse aggregate not exceeding 25mm,cement content not to be less then 150kg/cum,optimum moisture content to be determined during trial length construction , concrete strength not to be less then 10 Mpa at 7day ,mixed in a batching plant/ Weight batch mixer,transported to site with all leads and lifts,laid with a paver with electronic sensor / by suitable means as approved by Engineer-in-charges,compacting with vibratory roller ,finishing,curing and including preparation of Sub-grade Surface if required etc.complete

495

4418

2187139.43

... More
Providing and fixing position TMT FE 500, 25 mm dia dowel bars precoated with anticorrosive epoxy paint of required Dia. 60 cms. Long and 300.00 cm C/C and wherever directed including handling, straightning, necessary cutting supported by TMT FE 500, chairs with proper alignment by using propperly designed assembly of bulkheads lubricating half length with bitumen paint as directed etc. complete.

162

394

63828

... More
Providing and fixing in position TMT FE 500, tie bars precoated with anticorrosive epoxy paint of 12 mm dia. 70 cms.long and at 30.00 cm. C/C and wherever directed including handling, straightening wrapping with paper of approved quality for half length, necessary cutting, handling, straightening , supported by assembly of TMT FE 500, chairs with proper alignment etc. complete.

1284.71

213

273644.14

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil By Mechanical means

1205.43

532

641686.55

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary rock (not requiring blasting) Upto 3 m depth

69.45

557

38726.71

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard rock (requiring blasting)

224.8

923

207605.05

... More
Earthwork in excavation for structures as per drawing and technical specifications MORD 2014 Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard rock (Blasting Prohabited)

183.48

844

155000.23

... More
Removing all types of Hume pipes and stackig within a lead of 1000 m including Earthwork and Dismantling of Masonry work as per Technical Specification clause 202- Above 600 mm Upto 900 mm Diameter. Hume pipe

82.5

467

38536.58

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802,803, 1202 & 1203 P.C.C grade M 10 Nominal mix (1:3:6)

77.01

5897

454195.71

... More
Plain/reinforced cement concrete in sub structure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 - P.C.C grade M 15 Nominal mix (1:2.5:5)

924.4

6218

5747979.53

... More
Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.600 mm Diameter

37.5

2733

102487.5

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. 1000 mm Diametermeter

112.5

7069

795290.63

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.1200 mm Daimeter

45

9373

421800.3

... More
Providing weepholes in brick masonry / stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm Diameter AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification MORD 2014 Clauses 614, 709, 1204.3.7 A.C. pipe 100 mm Diametermeter

187.5

181

33988.13

... More
Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 1701

427.59

1

620

... More
Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015).

560

666

372960

... More
"Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15 cm wide strips, fitted with 80x100mm rectangular or 75mm Diametermeter. Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings"

130

822

106860

... More
Retroreflective tape (Engg Gr.)

50

1050

52500

... More
Ordinary Kilometer Stone (Precast) - Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703

4

2528

10112.28

... More
200 m stone (precast) - Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification MORD 2014 Clause 1703

12

524

6289.92

... More
Boundary Pillar / Guard Stone-Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704

280

598

167498.8

... More
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered/concrete surfaces as per drawing and Technical Specification Clause 1701

173.03

143

24864.65

... More
Providing and fixing Retro Reflective MMGSY/PMGSY LOGO informatory sign board with Logo as per section 1700 of MORD specification sand latest PMGSY Signage Manual/Circuler and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3mm ACP in Diametermetermond shape of 600x600 mm size, rivete dwith MS angle ironframe of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle ironframe of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat ironframe will be done neatly to have plain surface on one side. The angle ironframe of Both the plates will be welded to a 75mmx75mmx12 swg Mild steel post at/Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200 mm from normal ground level. The spacing between the Diametermetermond shaped plate and Lower Plate is kept 150mm. MMGSY/PMGSY logo, letters and numeral sonthe ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo MMGSY Logo Project description on ClassA or ClassB type retroreflective sheeting using modern technology printing plat form. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The in k sused for printing shall be ecofriendly with VOC emissions complying to UL2801 standards and specifications for the different kinds of plat forms. The printe dsign shall be laminated by UV protected laminate and shall carry awarranty of 5 years & 7 years for ClassA and ClassB sheeting respectively for traffic colors.” All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1(B) and as directed by Engineerin-charge. A warranty for 5/7 years for the Retroreflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.(SOR ITEM NO.10.16 ) A) Retro Reflective sheeting class-A

2

14759

29519.46

... More
MMGSY/PMGSY Citizen's information Board-Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specification sand latest PMGSY Sign age Manual/Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35x35x5mm thic kM. Sangle shall be welded by two vertical M.S angle of 5mm thick to 75mmx75mm of 12 SWG square tubes/75mm Diameter Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mmx600mmx75mm, below ground level . MMGSY/PMGSY logo, letter sand numer also n the ACP should be made up of Retro Reflective sheeting of Class-A/Class-B grade as per the latest MORD section1700 specifications (Refer Circuler no. NRRDA-P 013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo /MMGSY Logo/Project descriptionon ClassA or ClassB type retroreflective sheeting using modern technology printing platform. The printer shall be approved by the retroreflective sheeting manufacturer and printe dsign shall conform to retroreflective values as laid down in IRC67-2012. The inks used for printing shall bee co friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of plat forms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed post sand steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed

3

12364

37092

... More
Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 600 mm equilateral triangular

20

2352

47048

... More
Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 900 mm equilateral triangular

2

2352

4704.8

... More
Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheeting c. 600 x 450 mm Rectangular

4

2352

9409.6

... More
Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 600 mm square

4

2352

9409.6

... More
Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved, supported on a mild steel angle iron post 65mmX65mmX6mm-3.5mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing. Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retroreflective sheeting,Installation month & year, Warranty period for retro reflective sheetinga. 600 mm circular

5

2352

11762

... More
(Village Name Board) Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956-09 specifications, fixed over 4 mmt hick ACP sheet supported with Back support frame of 35x35x5 mm mild steel angle with are as not exceeding 0.9 sqm. Supported in mild steel angle iron post 75x75x6mm-3.5mt rheight, firmly fixed to the ground by means of properly designed foundation of M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level complete (as per MoRT & H specification No.801) (for area Less than 0.9 sqm). 7 Both border & background shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposure report from an independent test lab for the product offered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification:IRC67:2012. The reshall be as tamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.

1.8

3453

6216.55

... More
Metal Beam Crash Barrier -- Type - A, W : Metal Beam Crash Barrier (Providing and erecting a W "metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)

45

4912

221040

... More
Providing and laying White Topping as per IRC-SP 76-2015 over bituminous surface (Existing bituminous surface preparation to be done if necessary either by milling or levelling course with BM/DLC to correct surface profile and to be paid separately) with unreinforced M-30 grade Pavement Quality Concrete using Ordinary Portland Cement (OPC 43/OPC 53-Grade) at 357kg/cum and 105 kgs of Fly Ash (Replacement of Fly Ash to the extent of 15% and Fine aggregate by 10%) coarse aggregate, fine aggregate and Admixture confirming to IS 9130-1999 (R-2004) polymeric synthetic fibre as per ASTM (1116) such as polyester / polyethylene / polypropylene / Glass fibre at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher as per approved mix design to achieve minimum flexural strength or modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum water cement ratio to 0.40, transported to site, laid with mechanical paver finisher, spread, vibrated, compacted and finished in a continuous operation to the lines and grades as per drawing, texture finishing of surface, spraying two layers of curing compound, curing with water sprayed on hessian cloth covered over concrete surface, groove cutting grid 1m x 1m to a depth of 1/3 of the Thickness and of width 3-5 mm as per design including cost of all material, side form work, sealing joints labour and HOM of machineries etc. complete as per specifications.

742.5

8593

6380780.6



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.