Rural Development Department Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Rural Development Department - RDD Tender

Works
Civil And Construction
Eprocure
Opening Date30 Sep 2024
Closing Date8 Oct 2024
Tender Amount₹ 11,99,000 
Notes
Download

Costs

  • EMD

    ₹ 11,990
  • Document Cost

    ₹ 2,000
  • Tender Fee

    ₹ 500

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying in situ/Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete work in foundations like raft, strip foundations, grillage and footings of reinforced cement concrete columns and steel stanchions, excetra including bailling out water, formwork, cover blocks, compaction, curing and roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel), excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND). Item / Page No : 11 / 178 Specification No : Bd.F.3, B-7 Spec. Page No : 298, 38-40 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

3.41

26942

7901.1

... More
Providing and laying cast in situ / Ready Mix cement conrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed, including steel centering, formwork, cover blocks,aying/pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete.with fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 31 / 179 Specification No : Bd.F.5, B-7 Spec. Page No : 300, 38-40 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

3.23

48150

14907.4

... More
Providing second class burnt brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 in foundations and plinth of inner walls / in plinth of external walls including bailling out water manually, striking joints, on unexposed faces, racking out joints on exposed faces and watering, excetra complete. (using ARTIFICIAL SAND). Item / Page No : 1 / 197 Specification No : Bd.G.1 Spec. Page No : 313 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

2.63

23437

8911.65

... More
Filling in plinth and floors with approved excavated materials in 15 centimetre to 20 centimetre layers including watering and compacting, excetra complete. Item / Page No : 36 / 157 Specification No : Bd.A.10 Spec. Page No : 262-263

4.76

599

125.9

... More
Filling in plinth and floors with contractors material / brought from outside and approved by Engineer In-Charge, in 15 centimetre to 20 centimetre layers including watering and compaction, excetra complete. Item / Page No : 37 / 157 Specification No : Bd.A.11 Spec. Page No : 263-264

20.54

20987

1021.8

... More
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 50 / 181 Specification No : Bd.F.6, B-7 Spec. Page No : 300-301, 38-40 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

4.07

54209

13319.2

... More
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks,laying / pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 70 / 182 Specification No : Bd.F.8, B-7 Spec. Page No : 302-303, 38-40 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

6.74

101529

15063.7

... More
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap metal for reinforced cement concrete chajja as per detailed design and drawings including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate of natural sand/V.S.I. quality Artificial Sand (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 5 / 184 Specification No : BDF-9, B-7 Spec. Page No : 303-304, 38-40 Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

0.24

3615

15063.7

... More
Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For Ground Floor) Item / Page No : 33 / 188 Specification No : Bd.F.17 Spec. Page No : 306

1.64

154497

94263.45

... More
Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 5 / 197 Specification No : Bd.G.5 Spec. Page No : 315 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

14.15

129647

9162.35

... More
Providing and fixing mild steel grill work for windows, ventilator, excetra 20 kilogram per square metre as per drawings including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting, excetra complete. (For Ground Floor) Item / Page No : 1 / 264 Specification No : Bd.U.1 Spec. Page No : 537

13.5

29745

2203.35

... More
Providing and fixing in position (as per Indian Standard : 1868/1982) aluminium sliding window of three tracks with rectangular pipe having overall dimentsions 95 milimetre X 38 milimetre X 0.90 milimetre at weight 0.637 kilogram per running metre and window frame bottom track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 1.070 kilogram per running metre. Top and side track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 0.933 kilogram per running metre. The shutter should be of bearing bottom 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre. Interlocking secion 40 milimetre X 18 milimetre X 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections, fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jali with all required screws and nuts excetra complete. - With powder coating without box. (For Ground Floor) Item / Page No : 44 / 254 Additional Specifications : The work shall be done as per instructions of Engineer in charge.

13.5

70354

5211.45

... More
Providing internal cement plaster 12 milimetre thick in a single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 3 / 209 Specification No : Bd.L.2 Spec. Page No : 368 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

143.13

41428

289.45

... More
Providing sand faced plaster externally in cement mortar using approved screened sand in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at one killogramme per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment of 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days, scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 11 / 209 Specification No : Bd.L.7 Spec. Page No : 369 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

116.95

79771

682.1

... More
Providing and fixing frame with / without ventilator of size as specified with country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300 milimetre X 40 milimetre X 5 milimetre with oil painting, excetra complete. (For Ground Floor) Item / Page No : 1 / 245 Additional Specifications : The work shall be done as per instructions of Engineer in charge.

0.06

11961

209852.45

... More
Providing and fixing country cut teak wood double or single leaf second class fully panelled door shutter with 35 milimetre thick and style and rail 25 milimetre thick pannels with openable fan light as per detailed drawings, excluding the door frame 60 milimetre X 100 milimetre including stainless steel fixrtures and fastening and finishing the wood work with oil painting three coats, excetra complete.(Excluding the door frame) (For Ground Floor) Item / Page No : 4 / 245 Specification No : Bd.T.7, Bd.T.8 Spec. Page No : 481, 482

2.52

25308

10043.15

... More
Providing and applying plastic emulsiton paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface (excluding the primer coat), excetra complete. (For Ground Floor) Item / Page No : 12 / 227 Specification No : Bd.P.6 Spec. Page No : 414 Additional Specifications : The work shall be carried out as per instructions of Engineer in charge.

82.21

10004

121.7

... More
Providing and applying two coats of exterior weather shield paint of approved manufacturer and of approved colour to the plastered surfaces including cleaning, preparing the plaster surfaces, applying primer coat, scaffolding, if necessary and watering the surface for two days, excetra complete. (For Ground Floor) Item / Page No : 26 / 225 Additional Specifications : The work shall be carried out as per instructions of Engineer in charge.

93.04

28791

309.45

... More
Providing and laying vitrified matt finish tiles of having size 590 milimetre to 605 milimetre X to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 42 / 217 Specification No : Bd.M.12 Spec. Page No : 385 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

37.63

64546

1715.3

... More
Providing and laying in position flooring of telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on a bed of 1:6 cement mortar including cement float, striking joints, pointing in cement mortar 1:3, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 34 / 216 Specification No : Bd.M.3 B Spec. Page No : 380 Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.

5.44

23018

4231.3

... More
Providing and fixing 90 centimetre X 60 centimetre granite name plate engraving 10 centimetre height letter, figures including painting the letters / figures with approved colour and shade complete. Item / Page No : 12 / 294 Specification No : Bd.W.7 Spec. Page No : 586-587

1

9049

9049.7

... More
Royalty charges and surcharge on Royalty for various building construction bonafied materials which are used for government bonafied works and for which Royalty charges are to be paid by the contractor. (This Item is to be paid to the contractor only after he pays the Royalty amount to Revenue department and produces the required voucher.) Item / Page No : 3 / 0 Additional Specifications : 1. Government of Maharashtra, Revenue and Forest Department Gazette Number 146 Dated 04/06/2021 and Government of Maharashtra Public Works Department State Schedule of Rates 2021-22 General Note Number A(v), Page 5. 2. The amount of royalty charges will be paid only after submission of the receipt in original from Revenue authority for payment of royalty to Government, stating the name of work. 3. Above / below percentage quoted by the contractor will not be applicable for this item.

20.54

4440

216.18

... More
Laboratory testing charges for various materials required for items of work, on the basis of testing frequency and charges fixed by Vigilence and Quality Control Circle, Pune. Item / Page No : 4 / 0 Additional Specifications : 1. The amount of laboratory testing charges will be paid to contractor only after submission of the original receipt from the Vigillence and Quality Control Office with the name of work mensioned on it. 2. Above / below percentage quoted by the contractor will not be applicable for this item.Crushing Value / Compressive Strength, Water Absorption, Specific Gravity Test for Stone / Rubble 1 Test per

1

7761

7761

... More
Add 0.50 % for Insurance Non-Dsr Item Additional Specifications : The work shall be carried out as per the instructions of Engineer in-charge.

1

5008

5008

... More
Add 18 % for GST Non-Dsr Item Additional Specifications : The work shall be carried out as per the instructions of Engineer in-charge.

1

180273

180273



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.