Mumbai Metro Rail Corporation Limited Tender

... More
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Mumbai Metro Rail Corporation Limited - MMRC Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date12 Feb 2025
Closing Soon3 Mar 2025
Tender Amount₹ 5,98,00,000 
Notes
Download

AI Insights

Technical Capacity
... View More
The required prior work experience for the bidder is that they should have experience of having successfully completed similar works, with at least one similar work of value of Rs. 1.50 Crores or more, during the last 7 years. Similar work means any civil construction work for Government/Semi-Government organization, etc. The average annual turnover from works of any last three financial years should be at least 30% of the estimated cost, which is Rs. 5,98,00,000/-. This implies that the average annual turnover should be at least 30% of Rs. 5,98,00,000/-, i.e., Rs. 1,79,40,000/-. Relaxation may be given to Micro & Small Enterprises (MSEs) registered as manufacturer with relevant NIC code in Udhyam Registration & Start-up enterprises registered with DPIIT from work experience & turnover requirements. The required net worth certificate for financial year 2023-2024 should be of minimum 30% of the estimated cost, and the solvency certificate of the contractor’s financial stability should be 40% of the estimated cost put to tender, which is Rs. 5,98,00,000/-. This implies that the net worth certificate should be at least Rs. 1,79,40,000/- and the solvency certificate should be at least Rs. 2,39,20,000/-.

Costs

Summary

Balance Civil Works For Aarey Car Depot Of Mumbai Metro Line-3 Project

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Get the Best Price For TMT
Starting from
₹49,000/MT*
Maharashtra

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying and fixing of Maintenance Walkway System at roof top of upto 750mm width (FRP panel 3m x 0.75m x 30mm thick, 38 square opening with all fixing clamps & fasteners) with load carrying capacity upto 700 kg/m2 made up of FRP grating fixed to the roof sheeting with clamps made up of Galvanized Iron or suitable material as approved by Engineer in charge. 6 nos of SS clamps per grating. Clamps shall be locked with fasteners of Stainless-steel Grade-304 as per bimetallic compatibility strength. The seam clamps shall be installed over roof sheeting panels using stainless Steel fasteners. The clips are designed in such way that it suits the seam of installed panels, and it doesn't restrict the thermal movement of roof panels, etc complete as directed by Engineer-in-charge.

1072.5

4905

-

... More
Supply & installation of Fall Protection System with clamps suitable to the clip lock roofing sheets. 4 x split Aluminium clamps to be used below 4 corners of base plate (Roof sheet non-penetrating), as per the manufacture’s specification or as approved by Engineer in charge. The Fall Protection System shall be tested to EN795-2012 Class A2 & Class C and be capable of supporting 2 users working simultaneously at any point along the 8 mm 7 x 7 stainless steel cable even in the same area between 2 posts and shall demonstrate that an individual post is capable of absorbing a direct dynamic load of 300 kg dropped through 1.5m and limit the force to the roof to 10 kN in shear without damage to the roofing substrate, etc complete as directed by Engineer-in-charge.

1016

2036

-

... More
Providing and fixing aluminium work for windows chajjas, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make powder coated finish with any shade conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, at any height including necessary scaffolding cost, windows are located all each floor in OCC building (G+3) & Maintenance workshop building (G+1), etc complete as directed by Engineer-in-charge

8934.56

216

-

... More
Excavation in all types of soils, soft murum, including dressing/trimming the sides, leveling and ramming of bottoms, manual dewatering, disposing within an initial lead of 150m as directed, loading, unloading, leveling, etc. complete as directed by Engineer-in-Charge

200

387

-

... More
Excavation in hard rock/concrete, including dressing/trimming the sides, leveling and ramming of bottoms, manual dewatering, disposing within an initial lead of 150m as directed, loading, unloading, leveling, etc. complete as directed by Engineer-in-Charge

200

1347

-

... More
Demolishing R.C.C. slab/wall/beams/columns in any thickness and size manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead, etc complete as directed by Engineer-in-charge

220

2491

-

... More
Disposal of excavated/demolished/desilting materials of all types from work site to dumping site selected by contractor upto all lead including loading, unloading, stacking and spreading, etc. complete as directed by Engineer-in-charge.

1520

809

-

... More
Dewatering by using pumps of 10 HP capacity and other devices including disposing off water to safe distance, including cost of machinery, labour, fuel, pipe and it's accessories, etc. complete as directed by Engineer-in-charge.

100

104

-

... More
Providing & Laying dry stone Rubble Soling with average 230 mm size hard stone set in regular lines, handpacked and interstices thoroughly filled with small chips including filling in with good quality murum brought from outside, compacting with iron rammers, watering, sand spreading 12mm thk. layer of grit on top, etc complete as directed by Engineer-In-Charge.

109.69

2434

-

... More
Providing and laying RMC M-20 grade for PCC work as per IS 456:2000 including formwork, transportation, pouring, compaction and finishing the concrete with all contractors labour, machinery, material, lead, lift, curing with water, etc. complete as directed by Engineer-in-charge.

148.93

6432

-

... More
Providing and laying RMC M-35 grade for RCC work in structure/trench covers as per IS 456:2000 including formwork, transportation, pouring the concrete, compaction, finishing with all contractors labour, machinery, material, lead, lift, curing with water, etc. complete as directed by Engineer-in-charge.

62.35

10719

-

... More
Providing and fixing in position TMT Bars Reinforcement (Fe 500D or more) of various diameters for all structures, etc. as per detailed designs, drawings and schedules including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete as directed by Engineer-in-charge.

5

80080

-

... More
Providing preconstruction Anti termite Treatment as per IS: 6313 (Part-III) by treating the bottom surface, the sides of excavation, backfill in immediate contact with foundation, treating the top surface of plinth filling at the rate of 5 liters of emulsion concentrate of 0.5 % of chloropyiifos or equivalent per square meter of surface area covering 10 years' guarantee, etc. complete as directed by Engineer-in-charge.

100

187

-

... More
Filling with approved murum/good earth in layers not exceeding 200mm including breaking of clods, watering, consolidating each layer in filled up area by rolling and compacting with roller/ plate compactor as required to achieve not less than 97% modified proctor density conforming to relevant IS etc. complete as directed by Engineer-In-charge

470

1038

-

... More
Providing, laying, spreading & compacting specified crushed stone in Granular Subbase course including premixing the material in mechanical mixer (pug mill or approved type), spreading of mixed material in uniform layer of 100 mm to 75 mm (compacted thickness each) on prepared murum surface & compacting with 10 tonne vibratory roller to achieve desired density including all material, labour, machinery, lighting, barricading to all lifts & lead, maintenance of diversion etc. complete as directed by Engineer-in-charge. (metal gradation from 75mm to 75 micron as per prevailing specifications for Roadworks clause no.210)

320

2588

-

... More
Providing and laying Pavement Quality Concrete of M 40 grade including providing 125 micron thick impermeable plastic sheet membrane over the surface to be covered, coarse and fine aggregates of specified gradation using minimum cement content 350 kg/cum, cutting of dummy, transverse, longitudinal & expansion joints by mechanical means within 10 to 16 hrs of casting of bay/slab as directed , premoulded asphalt filler 12 mm thick conforming to I.S. 1838 of 1983, placing 5mm thick thermocol in dummy & construction joints immediately after cutting of joints & removing the same before dressing of dummy & construction joints, waterproof paper of 40 GSM including overlap ( to be not less than 10cm), cement vatas in c/m 1:10 at 0.6mx0.6m c/c admeasuring 0.09m at bottom, 0.04m at top & 0.075m, deep & maintaining the same throughout 14 days curing & removing the same thereafter, etc. complete as directed by Engineer-in-charge.

500

5928

-

... More
Providing and Laying hot applied Thermoplastic road marking strip of specified shade/colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm. Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC35:2015. Initial Dry reflectivity RL shall be 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100mcd/sqm/lux and Qd of 100mcd/sqm/lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easy lux, Deltamake capable of measuring RL & QD both according to IRC35:2015 clause15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications. (Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015), etc. complete as directed by Engineer-in-charge.

1500

666

-

... More
Providing and fixing of cement concrete Kerb Stone of size 500mm width x 325 height x 165mm thick (Half Batter, Bull Nose/ Full Batter) manufactured in wet press vacuum dewatering technology plant / equivalant with face pimple finish for high visibility with excellent quality and finish and edges perfect and sharp. Grade M-25 including excavation in any soil except rock, laying a leveling course of M 15 grade RMC 100mm thick to required slope (inclusive of form work), jointing in C.M. 1:2 proportion flush to concrete surface, painting exposed surface with one coat of primer and two coats of 1st grade road marking paint in the yellow/ white/ black or any shade, etc. complete as directed by Engineer-in-charge.

100

1123

-

... More
Providing and fixing of the precast tapered Water table of thickness varying from 105 to 125 mm, 300mm width in M-20 grade RMC inclusive of excavation in any soil except rock, laying of leveling course of M-15 grade RMC 100mm thick to the required slope, (inclusive of form work) jointing in 1:2 cement mortar, etc. complete as directed by Engineer-in-charge.

100

414

-

... More
Providing and applying Synthetic enamel paint or flat oil paint in any requiered shade in 3 coats over a primer coat as per manufacturers specifications including scrapping, cleaning the surface, etc. complete as directed by Engineer-in-charge.

500

197

-

... More
Brick work with common Burnt clay modular bricks of class designation 3.5 and above in superstructure above plinth level upto floor five level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand), etc complete as directed by Engineer In Charge.

20

10698

-

... More
Constructing precast Cement concrete solid block masonary (1:3) in valve chambers of any size and wall thickness, the concete block used shall be of 1:2:4 grade and of size 400x200x300, including racking of joints, curing etc complete and as directed by Engineer In Charge.

99.46

15290

-

... More
Providing and laying Autoclaved aerated (cellular) cement blocks masonry with more than 100 mm thick AAC blocks in Chemical Adhasive including RCC stiffeners. The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work, racking of joints, scaffolding and curing,etc. completed as directed by Engineer-in-Charge

10

8065

-

... More
Providing and applying 12 mm thick Internal plaster in cement mortar 1:3 with neeru finish at all heights and locations in one coat for masonry (except stone masonry) and concrete surfaces including racking out joints, hacking of concrete surface, watering, finishing, curing, scaffolding, etc complete as directed by Engineer-in-charge

326

427

-

... More
Providing and applying 20 mm thick External sand faced cement plaster in cement mortar 1:3 upto 10m from ground level and at all locations in cement mortar proportion specified below in two coats for masonry (except stone masonry) and concrete surfaces including providing water proofing compound to the first coat of plaster as per manufacturers specification, racking out joints, hacking of concrete surface, finishing, curing, scaffolding, etc complete as directed by Engineer-in-charge

326

542

-

... More
Providing Waterproofing treatment to the flooring as per manufacturers specifications of water closets, bathrooms, kitchen, nahanies, washing places, sanitary blocks etc. by giving injections with cement solution with water proofing compound into the floor slab so as to make it consistent, homogeneous and impervious against leakage, seepage etc. The sunk portion shall then be covered with brickbat waterproof coba in 1:5 c.s. of required thickness with necessary gradient for easy flow of water. Finally the floor shall be covered with joint less waterproof cement plaster in 1:3 c.s. 12 mm to 15 mm thick finished rough for receiving tiles. The average thickness of complete treatment shall not be less than 100 mm. The soil pan area will not be deducted. ( After completion of work leakage test shall be carried out after impounding the water for 7 days without any extra cost, etc complete as directed by Engineer-in-charge

20

619

-

... More
Providing Waterproofing treatment to the dado portion of as per manufacturers specifications the existing side walls upto 1.5 m height from floor area of water closets, bath-rooms, kitchens, washing places, sanitary blocks etc. by giving injections treatment with waterproofing compound and cement solution. The walls will then be plastered with waterproof cement plaster in 1:4 c.s. 12 mm to 15 mm thk. Finally the walls shall be covered with jointless waterproof plaster in 1:3 c.s. 12 to 15 mm thick finished rough for receiving tiles. The average thickness of complete treatment shall not be less than 25 mm, etc complete as directed by Engineer-in-charge

50

924

-

... More
Providing and applying Royale Luxury Emulsion paint of approved make on internal wall surface as detailed below Scrapping for surface with emery paper and wipe clean for area. wall primer with brush by adding mineral turpentine oil by 8 to 10% or water by 15 to 20% allowing to dry for 6 to 8 hours After applying acrylic wall putty with appropriate proportion of water of allow to dry for period of 4 to 6 hours of activity. Scrapping with emery paper and wipe clean Applying paints Royale Luxury emulsion1st coat with brush water content water 40 to 45 % or 65 to 70% by role Applying paints Royale luxury emulsion 2nd coat with brush with water content 40 to 45% or 65 to 70% by roller as per standard specifications, etc complete as directed by Engineer-in-charge

326

275

-

... More
Providing and applying Textured exterior paint of approved colour & shade to old and new surface including scaffolding preparing the surface to finishing with 2 coats as per standard specifications, etc complete as directed by Engineer-in-charge

326

236

-

... More
Providing and laying 20-25mm average thick Granite stone laid with knife edge joints over c.m. bedding of 1:6, for flooring / skirting / dado, with cement float and grout of same colour of the stone. The granite flooring shall be mirror polished, etc complete as directed by Engineer-in-charge

211.1

5257

-

... More
Providing and fixing 9 to 10 mm thk. Vitrified tiles as specified below conforming to I.S. 15622-2006 with water absorbtion less than 0.08% and of approved quality, pattern and colour for dado in the dry area including preparing the surface and levelling in the desired line, backing of 20 thk. cement mortar in porportion 1:3, square cut top edge or chamfered top edge in cement mortar 1:3, cement float, machine cutting, leveling, jointing, filling the joints with neat cement slurry or approved colour grout, finishing, curing etc complete as directed by Engineer In Charge. Light coloured glazed vitrified tiles/ Dark coloured glazed vitrified tiles/ Light coloured antiskid / matt vitrified tiles/ Dark coloured antiskid / matt vitrified tiles, etc complete as directed by Engineer-in-charge

164

1881

-

... More
Providing and laying 6 mm thk. Antiskid / matt ceramic tiles for flooring conforming to I.S.15622-2006 of an approved, quality, make, size and pattern /design, for flooring including cement mortar bedding of 25 mm thick in 1:4 proportion, neat cement float, cutting, leveling, jointing, filling the joints by neat cement slurry or approved colour grout, curing, finishing etc complete as directed by Engineer-in-charge

50

1508

-

... More
Providing and fixing 6mm thk. Ceramic glazed tiles for dado conforming to I.S. 15622-2006 of approved quality, pattern and colour in the wet area including preparing the surface and levelling in the desired line, backing of 20 thk. cement mortar in porportion 1:3 with approved waterproofing compound, square cut top edge or chamfered top edge in cement mortar 1:3, cement float, machine cutting, leveling, jointing, filling the joints with neat cement slurry or approved colour grout, finishing, curing, etc complete as directed by Engineer-in-charge.

20

1598

-

... More
Providing and laying rough natural Kota stone tiles 25 mm to 30 mm thick of an approved quality and size for flooring / skirting / dado including cement mortar bedding of 25 mm thick in 1:4 proportion, cement float, pointing in cement mortar 1:3, cutting, dressing, leveling, jointing, pointing, curing, finishing, etc complete as directed by Engineer-in-charge.

50

990

-

... More
Providing and Fixing of Rollar Blinds AMI Make or approved make & shade of 38 mm round Aluminium channel with Blackout fabric & telting with chain (Ball) system with all necessary fixtures and fitting as per standard specifications, etc complete as directed by Engineer-in-charge.

500

2152

-

... More
Providing and fixing single skin trapezoidal profiled Galvalume/Zincalume colour coated sheeting 930 - 1020mm cover width 28-32 mm crests depth at 186-250 c/c ( above 195 mm c/c crest distance there will be minimum 2 ribs at the centre for stiffening). The feed material shall be manufactured from AZ 150 (min. 150 gms/sq.mt total on both sides) sheets of minimum yield strength of 550 MPa, 0.45 mm BMT, ( 0.5 mm TCT excluding paint coating thickness), metallic hot dip coated with Al- Zn alloy (55% Aluminium, 43.5% Zinc, 1.5% Si ) as per AS 1397 /IS15961 & painted with Super Durable Polyester Colorbond steel XRW or equivalent quality paint system of apporved color, suitable for exterior application conforming to AS/NZS 2728:2007 type-4 / IS15965:class3 of approved make. The sheet shall have a total coating thickness of 35 microns, super durable polyester paint system of 20 microns on exposed surface and 5 micron reverse polyester coat on back surface over 5 micron primer coat on both surfaces. The paint system shall have stable inorganic pigments for color durability. The product will be fastened using no.12-14x55 mm (or as per design requirement ), mechanically coated with 25 micron Zn-Sn alloy or hot dipped zinc coated with min 40 micron hex self-drilling fasteners with EPDM washer of approved make confirms to AS3566:2002 class 3, etc complete as directed by Engineer-in-charge.

773

667

-

... More
Providing and fixing 600 mm dia Concertina barbed razer type coil of 19mm wide ribbon with thickness 5 SWG and central core wire of 12 SWG with antirust coating / Galvanization as per manufacturer specifications, supported over 5 rows of barbed wires of 14 SWG / Type II- conforming IS 278 and IS 4826, having two ply four points at 75mmc/c, fixed to Y shape angle bracket placed at 2.45m c/c (leg of Y should be fixed with 75x75x6mm thick insert plate , wing of Y should be 0.475m long having a distance of 0.58m between the two wing on the top) made up of 50mmx50mmx6mm M.S. angle fixed in column. The concertina coil should be fixed to angle with M.S. Flat 25mmx5mm thick on both the sides as runner all steel work shall be applied with one coat of red oxide zinc chromate primer and two coat of Synthetic Enamel paint, etc. complete as directed by Engineer-in-charge.

50

463

-

... More
Supplying & fixing precast SFRC heavy duty slab for inspection platform of M:40 grade (ordinary Portland cement 53 Grade) of size 1000 mm x 700 mm x 70 mm of 10 MT capacity (as per IS:12592:2002) of 130 to 145 Kg weight with 8 mm dia both side reinforcement jali (TMT Bars Fe 500 Grade) with side face MS sheet at edges 1.30 mm thick, 2 Nos lifting hooks 10 mm Dia TMT bars (grove inside flushing with surface), with engraving of MMRC logo & MMRC letter as per tender drawing, Anti skid surface, waterproof, weatherproof, theft proof, non-corossive, high strength, heat resistant, shockproof, MD 10T cap as per IS 12592:2002, etc complete as directed by Engineer-in-charge

300

1906

-

... More
Providing and laying NP2 Class R.C.C. Hume pipes with Collar joints conforming to IS 458:2003 and laid on approved bedding as per IS 783:1985 (Reaff. 2010) including jointing the pipes and filleting with hemp and stiff mix of cement mortar 1:2, including testing of pipes at contractor's costs (in presence of municipal staff) as per IS 3597 etc. complete as specified & as directed by Engineer-in-Charge

-

-

-

... More
150 mm diameter

50

537

-

... More
300 mm diameter

50

964

-

... More
600 mm diameter

10

4732

-

... More
Providing, supplying & laying HDPE Pipe Conforming to ISO 4427 of 1996, manufactured from virgin resin of PE-80 food grade compounded raw material having blue colour only with quality assurance certificate from quality agencies like CIPET(India) / DVGM / KIWA / SPGN / WRC etc. The cost shall include testing of all materials, labour, inspection charges, transportation, transit insurance, loading, unloading, stacking etc complete in all respect and as directed by Engineer In-Charge.

-

-

-

... More
50 mm dia. OD pipe PN 10

50

178

-

... More
110 mm dia. OD pipe PN 10

50

1048

-

... More
160 mm dia. OD pipe PN 10

500

1438

-

... More
250 mm dia. OD pipe PN 10

650

3197

-

... More
Providing and fixing H.D.P container one piece moulded Water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow pipe inclusive of all, etc complete as directed by Engineer-in-charge

50000

14

-

... More
Supply, fixing and installation of 4mm thick Aluminium Composite Panel (ACP) of approved colour for external cladding in combination of solid and metallic colours,including all necessary Framework, support and complete weather sealing as per architectural drawing. The Aluminium Composite Panel (ACP) should be made out of thermoplastic core of low-density polyethylene LDPE (100% virgin mix), sandwiched between two aluminium sheets of ALLOY GRADE- 5000 series, each not less than 0.50 mm thick, total thickness of aluminium composite panels not to be less than 4 mm, the exposed surface thereof shall have Stove lacquered finishing coat not less than (26 + - 2) micron (containing minimum 70% kynar 500 based PVDF) of colour and shade as per architectural design. The inside surface (facing the building exterior surface)shall have polyster based powder coating not less than 25 Micron with protective peel-off foil on the exterior face (peel off film will in no case leave any adhesive mark over the composite panel surface after it is peeled off). The supporting framework shall be made out of 50 mm X25mm X 3mm thick Aluminium section to be spaced horizontally and vertically for fixing of panel of size 900 mm X 1200 mm and fixed to the building structure as per design through 50mm X50mm X5 mm MS angle clamps prefixed to masonry or slab, columns with Hilti make anchor fastener screws. The fixing of panel to be done with the help of VHB tapes and screws and all the sealing of joints to be done with weather sealent Silicon, etc complete as directed by Engineer-in-charge.

50

3347

-

... More
Providing & fixing full height both side laminated partition at required location having height more than 2.8 meter made by using 50 x 50 mm (finished size) approved quality of 1.5 mm thick aluminium section framing at 600 mm x 600 mm center to center horizontally & vertically, covered with 12 mm marine ply generally confirming to I.S.303 / I.S.710-1980 on both sides.The partitions shall be finished with 1.5 mm thk.approved quality laminate matt/suede/fine line finished lamination pattern with grooves on both sides with necessary lipping (BTC) moulding. Antitermite treatment to plywood and woodwork, door frame including all leads & lifts, etc complete as directed by Engineer-in-charge.

290

5337

-

... More
Providing & Fixing in position 13.52 mm thk Glass (6mm Glass + 1.52mm Laminated Film + 6mm Glass) toughened Fixed glass door to be fixed with patch fitting, bottom pivot and floor spring as per manufacturer specification Providing & Fixing in position 13.52 mm thk Glass (6mm Glass + 1.52mm Laminated Film + 6mm Glass) toughened Fixed glass door to be fixed with patch fitting, bottom pivot and floor spring as per manufacturer specification with "D" Type SS 304 grade handles & lock, etc complete as directed by Engineer-in-charge

30

15785

-

... More
Providing and fixing superior quality factory made phenol bonded solid core single leaf flush commercial door 35 mm thick shutter of thickness as mentioned below and of approved make conforming to IS: 2202 (Part I, II) with 12mm thk. teak wood lipping all around, laminated finish on both sides including, approved fixtures and fastening hooks, eyes, screws of approved make and colour, etc complete as directed by Engineer-in-charge.

34.65

5674

-

... More
Supplying & installing Glass wool of TWIGA or equivalent make (approved by the Engineer-InCharge) having 50mm Thk. Density : 48 Kg. / M3) insulation with Woven make Fabric Black veil enclosed in 0.8 mm thk. G.I. back pan with SS Screws & Nut Bolts or necessary fitting. Including all necessary fittiings, accessories Including all necessary fittiings, accessories, etc complete as directed by Engineer-in-charge..

290

1338

-

... More
Providing &Fixing Frosted film manufactured by 3 M approved equivalent on glass partition wherever required, etc complete as directed by Engineer-in-charge.

50

953

-

... More
Removing existing flooring/dado tiles without disturbing bed concrete including stacking the materials as directed with all leads, lifts, etc complete as directed by Engineer-in-charge.

198.5

47

-

... More
Providing and constructing Granite kitchen platform with fixing of stainless steel sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of 75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite, etc complete as directed by Engineer-in-charge. (Platform top size 5.00 m x 0.60 m and height is 0.75 m)

50

7575

-

... More
Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts, etc complete as directed by Engineer-in-charge.

200

1363

-

... More
Providing and Fixing half turn 25 mm dia gun metal flushing cock including all accessories, etc complete as directed by Engineer-in-charge.

5

1001

-

... More
Providing and fixing 15 mm dia CPVC pipe with necessary fittings, making the opening in wall/floor including tapping connection to existing water line if required by all accessories, dismantling by core cutting and making good the damages to match existing surface, including disposal of malba, etc. complete, etc complete as directed by Engineer-in-charge.

200

266

-

... More
Providing and fixing 25 mm dia CPVC pipe with necessary fittings, making the opening in wall/floor including tapping connection to existing water line if required by all accessories, dismantling by core cutting and making good the damages to match existing surface, including disposal of malba, etc. complete, etc complete as directed by Engineer-in-charge.

1000

375

-

... More
Providing and fixing 32 mm dia CPVC pipe with necessary fittings, making the opening in wall/floor including tapping connection to existing water line if required by all accessories, dismantling by core cutting and making good the damages to match existing surface, including disposal of malba, etc. complete, etc complete as directed by Engineer-in-charge.

200

431

-

... More
Providing and fixing 40 mm dia CPVC pipe with necessary fittings, making the opening in wall/floor including tapping connection to existing water line by all accessories, dismantling by core cutting and making good the damages to match existing surface, including disposal of malba, etc. complete, etc complete as directed by Engineer-in-charge.

50

539

-

... More
Providing and fixing 100 mm dia UV resistant selffit UPVC pipes of approved make for Rainwater downtakes confirming to IS 13592:1992 Type A suitable for 4kg/sqcm pressure for following pipe diameters including rain water receiving recess with pvc plug bend necessary fittings such as offsets shoes, fixing the pipes on wall with clips filling the joints with solvent/cement and necessary scafolding, etc complete as directed by Engineer-in-charge

490

339

-

... More
Providing and fixing C. P. sink cock with raised 'J' shaped swinging casted spout (table mounted) jaquar make continental (Cat.No. CON- 359) including necessary fittings, etc complete as directed by Engineer-in-charge.

10

1529

-

... More
Providing and fixing European type wall-hung White water closet of approved make with push valve concealed type with cover plate 32mm size of approved make including soil pipe, vent pipe up to outside face of wall ,100mm dia. G.I. plug bend inlet pipe all fittings, cuttingand making good walls, floors, etc complete as directed by Engineer-in-charge.

10

11583

-

... More
Providing and fixing oval type under counter Wash hand basin of 16 inch x 22 inch size and of special colour shade having telephonic black / coloured granite of 180 mm thick stone black kadappa framework including chromium plated coupling bottle - Trap with oval typa wash basin model no 3448, etc complete as directed by Engineer-in-charge. (Counter size 1.20 m x 0.60m)

10

6783

-

... More
Providing and fixing in position 100 mm dia UPVC Nahani Trap including SS grating,fixing in cement concrete M-15, etc complete as directed by Engineer-in-charge.

20

539

-

... More
Providing and fixing C. P. Bib cock (ISI) jaquar make continental (Cat.No. CON-037) including necessary sockets/union nut, etc complete as directed by Engineer-in-charge.

40

778

-

... More
Providing and fixing Jet Spray with guarantee against any manufacturing defect including socket, union nuts, etc complete as directed by Engineer-in-charge.

20

1500

-

... More
Providing and fixing Flush Valve of approved quality, etc complete as directed by Engineer-in-charge.

20

3000

-

... More
Providing and fixing of Mirrors in rooms of approved Indian quality, copper plated with 10 mm thick plywood backing in the masonry etc complete as directed by Engineer-in-charge.

20

1500

-

... More
Supplying, Providing and fixing in position Hindware, Parryware or Jaquar approved make first quality, recessed, roller type or box type white glazed toilet paper holder 150 mm x 150 mm size, etc complete as directed by Engineer-in-charge.

20

1500

-

... More
Providing and fixing Chromium Plated Alluminium Towel Rail 750 mm (2‘6") long, 20mm (3/4") dia and of approved quality fixed on chromium plared bracket including providing teak wood gutties in masonry, etc complete as directed by Engineer-in-charge.

10

1500

-

... More
Providing and fixing C.P. Angular stop cock with wall flange of approved make continental including necessary sockets/union nut, etc complete as directed by Engineer-in-charge.

20

2821

-

... More
Providing and fixing in position Double coat hooks etc complete as per drawings, standard specifications and instructions of Engineer In Charge. etc complete as directed by Engineer-in-charge.

20

600

-

... More
Providing and fixing in position Towel Ring etc complete as directed by Engineer-in-charge.

20

1000

-

... More
Providing and fixing ISI marked make CP brass Liquid soap dispensers with CP brass bracket capacity 250 ml, etc complete as directed by Engineer-in-charge.

20

2748

-

... More
Supply of appropriate capacity Excavator-cum-loader/poclain machine on hire charges for cleaning of RCC box drains (Size 3.5 m x 3 m) by moving machine inside drains and lifting inside desilting material to ground level for any lift, inclusive of diesel, lube oil, Cleaner, Driver, cost of lowering down and lifting up machine from ground level to inside drain, etc complete as directed by Engineer-in-charge.

60

9775

-

... More
Supply of Dumper on hire charges inclusive of diesel,lube oil,Cleaner,Driver etc. without labourers, etc complete as directed by Engineer-in-charge.

40

5175

-

... More
Supply of Road Roller 8 to 10 M.T. Capacity inclusive of diesel,lube oil,Cleaner,Driver, etc complete as directed by Engineer-in-charge.

15

9660

-

... More
Supply of Unskilled labour for site cleaning activity, etc. complete as directed by Engineer-in-charge

500

783

-

... More
Providing, supplying & fixing heavy duty Plastic 75 mm Road hump safety speed breaker of 1 m in length in black & yellow colour for high visibility, interlocking between each module for more strength and durability fitted with Reflectors, easy installation with the help of Epoxy and specially manufactured Galvanised Iron Nails, etc complete as directed by Engineer-in-charge.

500

1186

-

... More
Providing, supplying & fixing premium quality Reflectors acrylic ultra strong plastic reflective stud markers industrial grade including fixing in concrete road/wall surface, etc complete as directed by Engineer-in-charge.

1000

652

-

... More
Providing, supplying & fixing industry Convex safety front Mirror 24 Inches/60 Cms Polycarbonate traffic mirror unbreakable round wide-angle driveway mirror, with adjustable brackets & nuts bolts for installation of mirror backside & clamp fixing, etc complete as directed by Engineer-in-charge.

50

1525

-

... More
Supply of water tanker:- Supply of Diesel water tanker having (Minimum 10,000 ltr. Capacity) for watering with pump & pipe including cost of water, etc complete as directed by Engineer-in-charge.

500

1250

-

... More
Supply, Installation, Testing & Commissioning of Booster Pump of 450 LPM at 70 m head, etc complete as directed by Engineer-in-charge.

4

81147

-

... More
Submersible flat cable 1st category– 4C x 2.5 Sq.mm, etc complete as directed by Engineer-in-charge.

30

199

-

... More
Earthing station with 600 mm x 600 mm x 6 mm galvanised iron plate & 50 mm dia. G.I. pipe, 3000mm long GI pipe (Class B or better) earth pit as per IS 3043. The earth pit shall be provided with watering pipe (Class B) with wire messed funnel, 25x3 GI strip/ / 2X8SWG G.I. wire up to chamber (wire or strip size as per fault level), disconnecting links with 600 x 600 mm (clear) RCC chamber & heavy duty 3mm thick CI chequered plate cover with hinge & stainless steel bolts. Bentonite/ Charcol & Salt shall be provided for earth pits. Excavation, back filling, removal of excess soil is included in the scope, etc complete as directed by Engineer-in-charge.

4

16475

-

... More
Providing and fixing in position G.I. Heavy grade 'C' class pipes 65 mm, etc complete as directed by Engineer-in-charge

200

1141

-

... More
Providing and fixing in position G.I. Heavy grade 'C' class pipes 50 mm, etc complete as directed by Engineer-in-charge.

460

914

-

... More
Providing and fixing in position G.I. Heavy grade 'C' class pipes 32 mm, etc complete as directed by Engineer-in-charge.

200

577

-

... More
2nd category Cu armoured cables FRLS outer sheathed- 4C x 25 Sq.mm 1.1 kV grade stranded Cu conductor, XLPE insulated, extruded PVC inner and FRLS outer sheathed, galvanised steel round or strip armoured cables (SP-ME-TS- 6), etc complete as directed by Engineer-in-charge.

135

910

-

... More
Supply & Laying of double wall corrugated (DWC) pipes 50 mm OD / 38 mm I.D. of HDPE for underground cable protection as per IS 14930 Part II. With necessary connecting socket/couplings, tees of some material at required depth up to 900 mm below road ground surface. backfilling of with light ramming is included in the scopeetc complete as directed by Engineer-in-charge.

110

164

-

... More
Cable end terminations for Copper Cables – 4C x 25 Sq.mm LV, XLPE/PVC insulated, PVC sheathed, armoured/ unarmoured cables including supply and fixing of Double compression cable glands, stripping of cable insulation, supply and fixing of tinned plated copper lugs for copper cables for all phases and crimping the same to the conductor for the following cables. Miscellaneous items like cable lugs, G.I nut - bolts and G.I washers , consumables and other hardware materials as required to make the installation complete, are in the scope. All G.I Nut, bolt and washers shall be HDGI with 80 micron. One set of termination includes gland, lugs for cable coe & accessoriesetc complete as directed by Engineer-in-charge.

4

331

-

... More
Gun metal gate valves (Flanged): -50 mm dia, etc complete as directed by Engineer-in-charge.

4

15335

-

... More
Gun metal gate valves (Flanged): -32 mm dia. Nos, etc complete as directed by Engineer-in-charge.

24

9459

-

... More
Gun metal non-return valve (Flanged) - 50 mm dia, etc complete as directed by Engineer-in-charge.

2

14682

-

... More
Supply & fixing Pressure Guage Range 0-10 Kg/Sq.cm Nos, etc complete as directed by Engineer-in-charge.

15

698

-

... More
Supplying and installing wall mounting swinging Hose reel drum fitted with 19 mm dia. 30m high pressure polypropylene (Polyhose) long fitted with necessary accessories as per specification, etc complete as directed by Engineer-in-charge.

15

12215

-

... More
Supplying & erecting Gun Metal Chrome plated Nozzle, 19 mm Ø complete as per specification Nos 2156, etc complete as directed by Engineer-in-charge.

24

2156

-

... More
Supplying & fixing multi functional industrial high pressure water spray gun, with necessary accessories, etc complete as directed by Engineer-in-charge.

15

11500

-

... More
Supply, Installation, Testing & Commissioning of 415 V Pump panel with 63 A MCCB as incomer with phase indicator, ammeter & voltmeter with selector switches, 2 Nos of 25 A MPCB with DOL starter, VFD control system with adjustable pressure governers system and local push button station & contactor of required rating as outgoing, etc complete as directed by Engineer-in-charge.

2

320000

-

... More
Supplying & fixing "S" type stainless steel 12 mm hook arrangement for securing hose pipe after use, etc complete as directed by Engineer-in-charge.

50

350

-

... More
Providing & fixing reinforcement of 8 mm dia. with Hilti RE500V3 at required location including drilling the hole 10 mm dia & 100 mm depth ,cleaning with blow pump and dispensing chemical and setting of rebar with HDM500/HDE500 (Excluding Reinfocement)

300

137

-

... More
Providing & fixing reinforcement of 10 mm dia. with Hilti RE500V3 at required location including drilling the hole 12 mm dia & 120 mm depth ,cleaning with blow pump and dispensing chemical and setting of rebar with HDM500/HDE500 (Excluding Reinfocement), etc complete as directed by Engineer-in-charge

500

204

-

... More
Providing & fixing reinforcement of 12 mm dia. with Hilti RE500V3 at required location including drilling the hole 14 mm dia & 143 mm depth ,cleaning with blow pump and dispensing chemical and setting of rebar with HDM500/HDE500 (Excluding Reinfocement), etc complete as directed by Engineer-in-charge

500

301

-

... More
Drilling with core cutting machine in RCC slabs, walls etc.wherever required in buildings, manholes,ducts, water tanks, pits etc. for laying pipes,sleeves and making good the same to give an even finish. The rate shall include the cost of drilling core, providing EPOXY based water proofing compound for sealing the joints around the pipes, nominal reinforcement wherever required,scaffolding and labour charges for working at all levels ,leads and heights. (Maximum thickness of RCC members shall be 300mm), etc complete as directed by Engineer-in-charge

-

-

-

... More
Above 25mm to 50mm dia

20

294

-

... More
Above 50mm to 75mm dia

20

393

-

... More
Above 75mm to 100mm dia

20

570

-

... More
Providing & erecting 9 m high (clear height) galvanized OCTAGONAL pole - Design, engineering, manufacture, testing at factory, packing & forwarding, delivery to site, unloading and handling at site, assembly, installation, testing and commissioning of Octagonal street light poles with embeded junction box inclusive of terminals, 3Cx 2.5 sqmm PVC insulated multistranded flexible copper cable from Junction box to the luminaires, termination at both ends and other accessories, with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification Nos 96775, etc complete as directed by Engineer-in-charge

15

96775

-

... More
Outdoor LED Street Light fittings – 130-150 W, etc complete as directed by Engineer-in-charge

15

8517

-

... More
Providing & erecting single arm standard bracket 1000MM long made up of 40 NB GI pipe suitable for octagonal pole of having top dia 70 MM as per specification, etc complete as directed by Engineer-in-charge

15

9181

-

... More
Bakelite sheet with MCB & Terminal ( for mounting inside the base compartment of the pole), etc complete as directed by Engineer-in-charge

15

1801

-

... More
1st category Al armoured cables FRLS outer sheathed- 4C x 25 Sq.mm, etc complete as directed by Engineer-in-charge

480

254

-

... More
Supply & Laying of double wall corrugated ( DWC) pipe 50 mm OD / 38 mm I.D., etc complete as directed by Engineer-in-charge

360

164

-

... More
S.I.T.C of maintenance free earthing comprising 17.2 mm electrode, etc complete as directed by Engineer-in-charge

6

12342

-

... More
Time controller for street light poles Nos 32922, etc complete as directed by Engineer-in-charge

1

32922

-

... More
Cable End Termination For Copper Cables – 4C x 25 Sq.mm, etc complete as directed by Engineer-in-charge

31

331

-

... More
Supplying & applying firestop wrap strip CP 648-E-W45/1.8" for sealing the gap of UPVC pipe, etc complete as directed by Engineer-in-charge

5

50483

-

... More
Supplying & applying Hilti CP636 mortar mix for sealing the cutouts in wall and floor etc. to make 02 hour fire rate and smoke seal, etc complete as directed by Engineer-in-charge

160

11671

-

... More
Supplying & applying firestop sealent FS-ONE MAX 10.1OZ CART to seal cable, pipe surrounding etc. to make 02 hour fire rate and smoke seal, etc complete as directed by Engineer-in-charge

5

2859

-

... More
Perforated Metal Ceiling: Providing and fixing 600 x 600mm mm Aluminium False ceiling tiles of approved colour. Aluminium grid panel ceiling consisting of panel 0.7mm thick for perforated panels. Depth and edge detail shall be as per manufacturer standard. Powder Coated with minimum thickness of 70micron+/-2micron.The Panels shall be separated with standard carrier system as per manufacturer drawing, etc complete as directed by Employer/Engineer. B. Suspension Suspension System shall be as per manufacturer standard. Panel shall be hung over panel carrier/metal grid. Sizes shall be as per manufacturer standard. Panel carrier shall be suspended by means of G.I. suspension rod and a Galvanized suspension spring. Providing and Fixing 600 X 600 mm aluminium metal tegular lay-in standard perforated tiles with 24 mm face exposed grid system Providing & Fixing horizontal level suspended ceiling comprising of Aluminium Lay-in Standard Perforated 600x600mm (Nominal Size) tiles made of AA-3003-H14 (Tempered) grade Aluminium suitable for architectural finishes in 0.7mm thickness as per in IS:2676 (1981) in White color RAL 9010 with Square Tegular edge having 8mm drop and 10mm flange. Tile shall have perforation of hole diameter as 2.5mm and open area as 16% with linear and diagonal pitch of 5.5mm and 7.7mm respectively along with a border of 10mm. The difference between the 2 diagonal dimensions of the tile to be less than 1mm. Tiles shall be flattened by precision leveller to minimize sag to less than 1/400mm. The tile shall be electrostatically polyester powder coated using RoHS compliant powder having coating thickness ranging from 60-80 microns. The powder coating shall pass Salt Spray Test for 750 hours as per ASTM B117, QUV –A Test for 1000 hours as per ASTM G-154 – (Cycle – 1) and Humidity test for 1000 hours as per DIN 50017. The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation across batches shall be delta E1 using Excite/BYK Gardner instrument and gloss level of 25±5% at 60˚ as per ASTM D523.The tile shall have a Light Reflectance of ≥ 63% in accordance to ASTM 1477-98. Back side of the tile shall have Soundtex or equivalent fleece hot pressed mechanically for uniform bonding to achieve NRC up to 0.7 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C-423 and Fire Performance of class 0/1 as per BS 476 Part 6 & 7 in module size of 600x600mm. All border cut tiles shall be laid, using lay-in end cap for installation to have a tegular effect on perimeters. Suspension: The tile shall be laid on 24 mm wide T - section flanges colour white RAL 9010 (matching to tile colour) having roll formed double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm (all sections). The deflection loading of the system shall be 15 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 18kg/m. The end details of the cross tee shall be made of pre hardened steel and fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kg. The T Sections shall be made of hot dipped galvanized steel of 90 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability. The Tile & Grid system used together shall carry a 10 year warranty against manufacturing defect and manufacturer shall provide a warranty certificate. The Tile & Grid shall have the manufacturers name embossed/printed on it. The supply shall be backed by a Manufacturing Test Certificate. Installation: To comprise main runner spaced at 1200mm securely fixed to the structural soffit using suspension system (specifications above) at 1200mm maximum. The First/Last suspension system at the end of each main runner shall not be greater than 450mm from the adjacent wall along with the first and the last main beam shall be at less than 600mm from the wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be wall angles of size 3000x19x19mm, secured to walls using screws at 450mm centre to centre maximum. Installation shall be carried out as per Manufacturer recommended procedure. Suspension system accessories supplied by Manufacturer consisting of M6 Anchor Fasteners with hanger hole, pre-straightened hanger wire of dia – 2.5 mm of 1.80 m length having a tensile strength of 344-413 MPa and a minimum loading strength of 110 kgs. (Optionally, adjustable hook clips made of 0.7mm thick Grade 1 C55 galvanized spring steel of dimension 100 x 20mm and 4 mm aquiline wire to be used for level adjustment during installation purpose in main runners).

100

2320

-

... More
Providing & fixing open cell 150 mm cell size lay-in aluminium ceiling with 15 mm exposed grid system, etc complete as directed by Engineer-in-charge Providing and fixing horizontal level Open cell Aluminium lay-in ceiling tiles with border panels forming board edge of size 600x600x38mm (Nominal) having cell size of 150x150mm made of AA-3003-H14 (Tempered) grade Aluminium suitable for architectural finishes in 0.35mm thickness as per in IS:2676 (1981) in white color RAL 9010 The tile shall be electrostatically polyester powder coated using RoHS compliant powder having coating thickness ranging from 60-80 microns. The powder coating shall pass Salt Spray Test for 750 hours as per ASTM B117, QUV –A Test for 1000 hours as per ASTM G-154 – (Cycle – 1) and Humidity test for 1000 hours as per DIN 50017. The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation across batches shall be delta E1 using Excite/BYK Gardner instrument and gloss level of 25±5% at 60˚ as per ASTM D523. Tile shall have a Fire Performance class A as per GB 8624-2012. Suspension: The tile shall be laid on 15 mm wide T - section flanges colour white RAL 9010 (matching to tile colour) having double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm (all sections). The deflection loading of the system shall be 12.5 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 15kg/m. The end details of the cross tee shall be made of pre hardened steel clip fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kg. The T Sections shall be made of hot dipped galvanized steel 90 gsm and pre-painted steel with baked polyester paint of 0T bending capability. The Tile & Grid system used together shall carry a 10 year warranty against manufacturing defect and manufacturer shall provide a warranty certificate. The Tile & Grid shall have the manufacturers name embossed/printed on it. The supply shall be backed by a Manufacturing Test Certificate. Installation: To comprise main runner spaced at 1200mm securely fixed to the structural soffit using suspension system (specifications below) at 1200mm maximum. The First/Last suspension system at the end of each main runner shall not be greater than 450mm from the adjacent wall along with the first and the last main beam shall be at less than 600mm from the wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be wall angles of size 3000x19x19mm, secured to walls using screws at 450mm centre to centre maximum. All border cut tiles shall be laid, using lay-in end cap for installation to have a Microlook effect on perimeters. Installation shall be carried out as per Manufacturer recommended procedure. Suspension system accessories manufactured and supplied by Manufacturer consisting of M6 Anchor Fasteners with hanger hole, pre Straightened Hanger wire of dia – 2.5 mm of 1.80 m length having a tensile strength of 344-413 MPa and a minimum loading strength of 110 kgs. Additionally, adjustable hook clips made of 0.7mm thick Grade 1 C55 galvanized spring steel of dimension 100 x 20mm and 4 mm aquiline wire to be used for level adjustment during installation purpose in main runners.

100

2010

-

... More
Refixing & rework of ceiling tiles including frames at Station builiding, workshop and at OCC building, etc complete as directed by Engineer-in-charge.

300

426

-

... More
Providing rubber strip/sealing strip for maintaining the gap between platform edge and train access platform as per CSD. Use EPDM material for rubber strip/sealing strip of thickness 5 to 10 mm, black in colour. Materail should be Fire resistance as per BS476 & BS 6853, etc complete as directed by Engineer-in-charge.

600

1356

-

... More
Grouting pockets, holes, pipe sleeves of any shape or size for column bases, machine foundations, etc. with ready to use non shrink high strength grout of approved make, as per manufacturer’s specifications and instructions/ recommendations, including roughening of surfaces, cleaning with compressed air/ water jets, ramming, curing, etc. complete.

2506

225

-

... More
Supply of Mobile crane - with boom length 30m on hire charges for lifting/refixing of heavy drain MS covers, inclusive of diesel, lube oil, Cleaner, Driver, etc complete as directed by Engineer-in-charge.

50

11000

-

... More
P/f Polyethylene plastic water/sand fillable Metro Barricades having approx. size 1840 mm X 440 mm X 1900 mm, (LxWxD), 32-35 Kgs empty wt. and tank capacity 100-120 lits., manufactured by ISO Certified Company having minimum experience of 3 years in manufacturing and supplying to the Govt./Semi Govt./Other reputed organisations alongwith necessary fixing arrangement as specified and directed by the Engineer Incharge

68

321

-

... More
Red and White Caution Tape for Work in Progress Danger Barricade Tape, Non-Adhesive Barricade Warning Tape, Construction Tape Polyethylene Material

1260

3

-

... More
Supply & fixing of approved quality and approved pattern of tactile 300*300 25mm thick (yellow tactile) to guide the access from road to the station.

100

100

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.