Military Engineer Services Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Electrical and Electronics
Solar Installation and Products
Eprocure
Opening Date3 Sep 2024
Closing Date1 Oct 2024
Tender Amount₹ 45,60,000
Costs
EMD
₹ 91,200Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_671092_1Bid Award Id
ViewTender No
GE/LONAVLA/8259/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
General Pages, Errata on NIT, Schedule Of Credit, Special Conditions, Particulars Specifications
BOQ Items
S & F switch piano, 15 Amp, single pole, flush type one way 230 volts complete all as specified and as directed.
30
-
-
S&F in repairs ceiling rose three terminal/PVC polycarbonate, isolated body complete all as specified.
30
-
-
Supply and fixing in replacement of LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.Make: Crompton or equivlent Bajaj/Philips/Havells
40
-
-
Supply and fixing in replacement of LED Inverter street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.Make: Halonix or equivlent Bajaj/Philips/Havells
60
-
-
Supply and fixing Higher wattage flood light luminaire with ultra sleek, light weight and secondary optics,made of pressure die cast housings with IP66 ingress protection and impact resistance of IK07.4kv inbult and 10kv external surge protection .Make : Bajaj (BJFL 100W LED I ) or equivalent Shati/Havells...
25
-
-
Supply and fixing in replacement of Higher wattage flood light luminaire with ultra sleek, light weight and secondary optics,made of pressure die cast housings with IP66 ingress protection and impact resistance of IK07.4kv inbult and 10kv external surge protection .Make : Bajaj (BJFL 150W LED I ) or equivalent Shakti/Havells...
25
-
-
Supply and fixing in replacement of Higher wattage flood light luminaire with ultra sleek, light weight and secondary optics,made of pressure die cast housings with IP66 ingress protection and impact resistance of IK07.4kv inbult and 10kv external surge protection .Make : Bajaj (BJFL 200W LED I ) or equivalent Shakti/Havells...
25
-
-
Supply and fixing Higher wattage flood light (Warm White)luminaire with ultra sleek, light weight and secondary optics,made of pressure die cast housings with IP66 ingress protection and impact resistance of IK07.4kv inbult and 10kv external surge protection .Make : Bajaj (BJFL 80W LED I WW ) or equivalent Shakti/Havells...
20
-
-
Supply and fixing in replacement of energy saving, envroment friendly & robust mediumby/Hiighbay LED luminaire with high efficacy (100 im/W) with toughened glass. Make : havells cat no- GAZELLAHBP100WLED857PBOTG or equivlent Philips/Bajaj. Note: All Highbay light hanging with truss ,all wiring done in casing caping or in condute as per site required,additional accesories price including in this rate.
10
-
-
Supply & fixing in replacement of UP and DOWN LED light 15 Watt IP- 66 LED Make:Havells (CLIOWLS15WLED830PSYMTOTG ) HSN code 9405 or equivalent to Shakthi/Philips/Wipro complete all as specified and directed
20
-
-
Supply and fixing in replacement of LED Bolard with opal acrylic diffuser and IP 65 protection all as specicified and directed. Make : Bajaj (BGBOM 605 9W LED WW) OR equilvent Philips/havells.
21
-
-
Supply and fixing in replacement of LED Bolard in rectangular shaped victorian design with opal acrylic diffuser and IP 65 protection all as specicified and directed. Make : Bajaj (BGBOS 600 9W LED WW) OR equilvent Philips/havells.
15
-
-
Supply and fixing in replacement of Decorative Globe LED Post Top (25W) LED WW made in dia cast aluminium housing with decorative clear opal acrylic diffuser and IP 65 protection all as specifiend as direction.Make : Bajaj (BGCTN 25W LED WW) or equivalent Philips/Havells.
15
-
-
Supply and fixing in replacement of Decorative Globe LED Post Top (25W) LED wall light in spherical hape polycarbonate diffuser IP 65 protection all as specifiend as direction.Make : Bajaj (BLPTSP 25W LED WW) or equivalent Philips/Havells.
15
-
-
S&F in replacemen MCB DB SPN 2 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface all as specified and directed
6
-
-
S&F in replacemen MCB DB SPN 4 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface all as specified and directed
6
-
-
S&F in repairs MCB SPN 40 to 63 AMP, 240 Volts 10KA 'C' curve , Complete all as specified and directed.
12
-
-
S&F in repairs MCB SP 5 to 32 ,single pole 240 Volts 10KA 'C' curve, Complete all as specified and directed.
12
-
-
M&L for sub main wiring drawing through PVC casing and capping with two single core 4 sq mm and one run of 4 sq mm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts grade all as directed. Note:- Three run of 4 sqmm wire and One run of PVC casing caping will be measured as one running meter.
360
-
-
M&L for sub main wiring drawing through PVC casing and capping with two runs of single core 6 sq mm and one runs of 6.0 sq mm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts grade all as directed.Note:- Three run of 6 sqmm wire and One run of PVC casing caping will be measured as one running meter.
400
-
-
M&L for in replacement of earthling complete with galvanized GI earth plate electrode of size 600x600x6.00 mm, buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanized earth lead wire 4.0 mm dia by means of volts, nuts, check nut and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate as shown in electrical plate No 3 of SSR part1991,20 mm dia watering pipe medium grade 1.50 mtr long GI protection pipe light grade 15 mm dia from earth pit to main board (NOTE:- maximum length of GI protection pipe with each earth shall not be less than 7.5 mtrs) including necessary pit with cover , including testing on complition.
9
-
-
S&F in replacement of PVC insulated and FR PVC Round Sheathed, Copper Conductor (2.5sqmm x 3 core)
(flexible) industrial cable, 1100 Volt, conforming to IS 694 for sub main wiring drawing through PVC casing and capping/ saddling by saddle/under PVC condute all as directed by EIC.Make: Havells or equilent KEI/Polycab
400
-
-
S & F in replacement of flexiable pipe for camoflage of loos wiring with verious size as directed by Engg - in Charge
200
-
-
Supply and fixinng in replacement of saddle for sequiring of all sizes cables with nut bolts and connected acessories complete all as specified and as directed by Engr-in -charge. Note : Saddle size as per site cable requirment provide by contractor.
100
-
-
WINDOW/SPLIT AC M&L for repairs to window type AC of 1.5 TR capacity by removing the electrical connection, dismantling the machines for repair, cleaning the machines properly from inside and outside, greasing/ oiling ,replacing the minor nut bolt, washers and re-fixing after repair including spray painting of bottom plate with one coat of synthetic enamel paint, testing and commissioning complete all as specified and as directed.
8
-
-
M&L for repairs to AC/window/split type by disconnecting of connection and removing the leakage in the system of machine, charging of refrigerant gas F-22 and reconnecting sealing properly and testing for proper cooling complete all as specified and as directed.
Note:- Refrigent gas required will be measured and paid separately under relavent item of schedule.
6
-
-
S&F in replacement compressor, rotary type suitable for 1.50/ 2.00 TR capacity Air conditioner including input/output connections of electric, supply and charging of refrigerants gas and testing/ commissioning complete all as specified and as directed.
3
-
-
M&L for repairs to blower motor by taking out the defective blower motor of window type AC 1.5 /2.0 TR capacity of any make/type for repair, dismantling the motor, removing the defective winding the cleaning the slots, rewinding the motor with super enameled winding wire of existing suitable gauge, varnishing, baking, over-hauling and testing, commissioning complete all as specified and as directed.
2
-
-
Supply and fix in replacement running capacitor, 36-45 mfd for window type/ Split type AC complete all as specified and as directed.
1
-
-
Supply and fix in replacement starting capacitor for 80/100 MFD, for window type/split type AC complete all as specified and as directed.
2
-
-
S&F in replacement fully automatic thermostat switch suitable For window/split type AC capacity 1.5 /2.0 ltr.
2
-
-
Supply and fix in replacement box type relay suitable for AC window/split type 1.5/2.0 TR capacity
2
-
-
Supply & fix in replacement over load protection relay for AC of 1.5/ 2.0 TR capacity, window/split type.
3
-
-
S&F in replacement indoor fan motor suitable for split type AC of any capacity and any make complete all as specified and as directed.
2
-
-
S&F in replacement condensor for fan motor suitable for split type AC of any cap and any make complete all as specified and as directed.
2
-
-
Supply and fix in replacement copper tube of size 1/4'' suitable for split type AC complete all as specified and as directed.
3
-
-
Supply and fix in replacement copper tube of size 1/2'' suitable for split type AC complete all as specified and as directed.
4
-
-
S&F in replacement of PCB remote kit suitable for split type AC of any capacity and any make complete all as specified and as directed.
2
-
-
WATER COOLER M&L for repairs to water coolers by any capacity by removing the electrical connections and water connection from the machines for repair, dismantling the machines for repair cleaning the machines properly from inside and outside, greasing, oiling, replacing the minor parts i.e. nut bolt, washers and re-fixing after repair including spray painting with one coat of synthetic enamel paint, testing & commissioning complete all as specified and as directed.
3
-
-
S&F in replacement compressor sealed type suitable for water cooler of Capacity 40/80 Ltr including inlet/ outlet connections of electric supply, testing and commissioning complete all as specified and as directed.
3
-
-
S&F in replacement condensor fan motor suitable for water cooler of any cap and any make complete all as specified and as directed.
1
-
-
S&F in replacement fully automatic thermostat switch suitable For water cooler storage type.
2
-
-
Supply & fix in replacement over load protection relay for Water cooler storage type of any capacity.
2
-
-
Supply and fix in replacement running capacitor, 36-45 mfd for Water Cooler complete all as specified and as directed.
2
-
-
Supply and fix in replacement starting capacitor for 80/100 MFD, for Water cooler complete all as specified and as directed.
2
-
-
REFRIGERATOR M&L for repairs to refrigerator of any capacity and made by disconnecting and removing the leakages in the system of machine, charging of refrigerant gas R-134A, reconnecting, sealing properly, and testing for proper cooling complete all as specified and as directed.
Note:- Refrigent gas required will be measured and paid separately under relavent item of schedule.
4
-
-
S&F in replacement freezer fan motor suitable for refrigerator of any capacity and any make complete all as specified and as directed.
2
-
-
S&F in replacement bimetal contact suitable for refrigerator of any cap and any make complete all as specified and as directed.
2
-
-
S&F in replacement timer suitable for refrigerator of any make and any capacity complete all as specified and as directed.
2
-
-
S&F in replacement compressor, sealed type suitable for refrigerator of any capacity including inlet/ outlet connections of electric supply, testing and commissioning complete all as specified and as directed. a) Refrigerator upto Cap 180
3
-
-
All as per item no 53 above but of Refrigerator upto Cap 300
1
-
-
S&F in replacement sealed type compressor suitable for deep freezer of 400/450 ltr cap and any make complete all as specified and as directed.
2
-
-
Supply & fix in replacement over load protection relay for Refrigerator of any cap
2
-
-
S&F in replacement fully automatic thermostat switch suitable For refrigerator upto 300 ltrs capacity.
1
-
-
S&F in replacement fully automatic thermostat switch suitable For deep freezer of any capacity
1
-
-
S&F in replacement starting relay for refrigerator of any cap and any make complete all as specified and as directed.
2
-
-
Supply only refrigerant gas R-22.
3
-
-
Supply only refrigerant gas R-32.
3
-
-
Supply only refrigerant gas R-410
3
-
-
Supply only refrigerant gas F-134A.
3
-
-
2MW Solar S&F in repalcement of DC cable 1x 4 sq mm multi strand tinned copper, conforming to relavant IS, weather proof UV resistant with operating temperature up to 120 degrees, minimum rated voltage 1100 volt all as per approved design parameters complete for inter connection of SPV Modules for string connection including suitable type of cable lugs, male & femaleMC4 connectors & joints all as per IS, having voltage rating 1100 VDC (IEC), rated current of 30A, complete all as specified and as directed.
800
-
-
S&F in repalcement of NIBBO MC4 Connectors male and female for concted DC cablr (6sqmm) complete all as specified and as directed.
100
-
-
S&F in repalcement of 25mm MMS PVC pipe diamond for use protecting in underground (6mm) DC cablecomplete all as specified and as directed.
200
-
-
S&F in repalcement of DC cable 2 single run of 6 sqmm multi strand tinned copper, conforming to relevant IS , weather proof UV resistant with operating temperature up to 120 degrees, minimum rated voltage 1100 volt all as per approved design parameters complete for inter connection from String to SPB including suitable type of cable lugs, male & female MC4 connectors & joints all as per IS, having voltage rating 1100 VDC (IEC), rated current of 30A, complete all as specified and as directed. (NOTE: Two runs of 6 sq mm DC cable and one run of HDPE pipe of dia 20 mm/nearest standard size shall be measured as one unit length)
800
-
-
S&F in repalcement of LT DC power cable 2 runs of 1 core x240 sq mm Phase + Neutral) 1100 volt with multi stranded copper conductor, XLPE insulated, armoured, conforming to IS (ST-2) PVC inner sheathed, (C2 category type FRLS) (ST-2) PVC outer sheathed complete incl suitable size end terminations with Glands, Lugs, joints etc complete for connection from all SPBs to PCU/Inverter all as specified and as directed.
190
-
-
S&F in repalcement of CAT 5 Data cable from PCUs to SCADA all as specified and as directed
100
-
-
S&F in repalcement of RS485 cables (unarmoured) from relays, SMBs, MFM/TVM, neumerical meters to SCADA system , weather monitoring system to SCADA, ABT / interface meter to SCADA all as specified and as directed
250
-
-
Repair/Maintance of Single phase double conversion on line UPS of capacity 5 KVA conf to IEC 60950 complete with battery bank & ABM (Advance Battery Management) having 2 hour back up for output connection 230 V including LCD display and noise level 50 dB (A) at 1 meter complete with the following:- (a) Battery bank suitable for 5kVA capacity with VRLA battery bank conf to IS 1651-1979, performance as per IS-8702, nominal cell voltage 2 V,plastic resin/ABS/PP container, epoxy coated exhaust fans to remove the gas emissions, Suitable rack/stand. for continious operation of 2 hours backup. (b) Float-Cum-Boost charger of required rating with regulator including for trickle charging. (c) controlpanel with LED indication & alarm annunciation on the panel for Main ON, DC ON, chargering position, etc .spare parts and replace item rate including this rate,all as specified and as directed.
1
-
-
Repair/Replacement Detectors Complying with and type certified to EN-45 Addressable type multisensor detector with heat and smoke combination Photoelectric / Optical with base with self built intelligence as per IS: 11360 all as specified and as directed.
3
-
-
Repair/Replacement Short circuit isolators all as specified and as directed.
2
-
-
Repair/Replacement Addressable manual call point resettable type
2
-
-
Repair/Replacement Addressable electronic sounder cum strobe
1
-
-
Repair/Replacement of DC to DC convertor for Invertor of solar plant as specified and as directed.
1
-
-
S&F replacement of Danger notice plate of 1.6mm thick mild steel, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for HT, 25x20cm.
4
-
-
S&F replacement Cable route indicator 15cm dia made out of cast aluminium duly marked with size and type of cable fixed on ISA 40x40x6mm angle iron support embedded including in PCC 1:2:4 type B1 (300x300x400mm) and steel surface painted with two coats of anti corrosive paint over a coat of red oxide primer including necessary earth work all as specified and directed.
40
-
-
Supply and fix FR PVC insulated cable 1100 V grade with multistranded copper conductor of size 1.5 Sqmm 3 core conductor all as s specified and directed by Engineer-In -Charge at site. Make : polycab,Havells,KEI
350
-
-
Supply and lay in trenches / along the wall / floor / on poles / pillars / for road / Nallah crossing, pipes GI light grade of size 100 mm dia with and including all fittings and accessories complete including taking down the old unsv all as specified and and directed for cable protection
77
-
-
Cutting and filling with PCC (1:3:6) in bituminus road/Hard surface as per direction of Engr in Charge for laying of UG cable and match the existing road to the existing system.
77
-
-
M&L for Scrubing of existing rusted surface of any size poles long and prepration and painting of surfaces with one coat of red oxide and two coat aliminium paint fine finishing includign cross arms bracing , clamps and supports complete all as specified and as directed.
25
-
-
M&L for Marking of any size pole , Scrubing of existing rusted/unread surface of poles and prepration surfaces for marking, Marking done by two colour. numbers marking done by white colour and back side colour and shape as per direction of Engr in Charge .
5
-
-
Solar water heater :- Supply and fix in replacement of MS stand suitable for up to 1000 LPD solar water heater complete all as specified and directed by Engineer-in-Charge.
1
-
-
M & L for servicing of solar water heater upto 1000 ltrs capacity including checking serviceability of individual componenets and replacement of worn out fasteners, gaskets, washers accessories, inspection of the entire system, cleaning of sacrificial anode, rectification of any leaks, tightening of electric loose connections etc. and making system operational complete all as specified and directed by Engineer-in-Charge. Note: (i) Spares will be measured and paid separately under relevant item of sch 'A'
5
-
-
Supply and fix in replacement of solar water tube 58x1500mm for the solar water heaters complete all as specified and directed by Engineer-in-Charge.
5
-
-
Supply and fix in replacement of solar water tube 58x1800mm for the solar water heaters complete all as specified and directed by Engineer-in-Charge.
5
-
-
Supply and fix in replacement of silicon washers for hot water tank suitable for EGTS complete all as specified and directed by Engineer-in-Charge.
10
-
-
Supply and fix in replacement of LLDPE cap washer at top of the EGTS complete all as specified and directed by Engineer-in-Charge.
10
-
-
Supply and fix in replacement of LLDPE washer at bottom of the EGTS complete all as specified and directed by Engineer-in-Charge.
10
-
-
Supply and fix in replacement of flat plate collector- 2 m x 1m ISI marked as per MNRE standard complete all as specified and directed by Engineer-in-Charge.
2
-
-
Supply and fix in replacement of hose pipe to connect hot water tank of flat collector complete all as specified and directed by Engineer-in-Charge.
60
-
-
Supply & fix in replacement of heating element ISI marked of size 3 KW, 230 volts required for solar water heater complete all as specified and directed by Engineer-in-Charge.
5
-
-
Receiving complaints Daily basis from JE incharge lodged by the user/occupants of security/ street light / concern external electric supply nature, rectification of the fault as per the detailed by JE incharge/ AGE E/M to rectify the fault with regard to complaint lodged and refixing of fitting and fixture to their original position as dismentled complete all as directed at site to the entire satisfaction of Engineer -in- Charge.
Note : (i) Any copmplaint which is left out/unattendent 1-2 days by the electrician by any reasons the same to be communicated to the JE incharge /AGE E/M with reason. (ii) Rates quoted shall be deemed to include the cost of minor spares not catered for in the subject CA (such as bracket,clamp,nut bolt,led light with connecting acessories etc)
(ii) New material/stores provided for completing the job shall be measured and paid for separetely under relevent items of sch 'A' and supply issue resolve such as cable loose/disconect connection complain deemed including this rate.
(iii) Contractor shall provide the all type of T & P,vehicle,ledder and saftey items such as electric proof shooes and hand gloves,body harnese to electrician for attending & rectification the internal / external electric complaints. (iv) Contractor shall provide the complaint register and complaint slip serially numbered in duplicate as per sample. The rate of such items included in this items.
(v) Any unattended complaints not done in specified time limit. The contractor shall penalty Rs. 500/- on each complaints per day.
600
-
-
Excavation in trenches not exc. 1.5m wide and not exc 1.5m in depth and getting out in soft and loose soil for laying of cable trenches all as specified and directed.
222.75
-
-
All as per item No.95 Herein before but in hard dense soil
44.55
-
-
Returning filling in, including spreading, levelling, watering and well ramming in layer not exc 25cm all as specified.
159.07
-
-
Removal of surplus soil (excavated soil) to distance not exceeding 50m and depositing where directed at a level not exc 1.5m above the starting point and all specified.
108.23
-
-
M&L for providing dry river sand / crush stone dust for cushioning to UG cable including punning down of sand in layers all as specified. Note :- Cushioning will be measured and paid after punning down.
80.19
-
-
Supply and laying factory cast, unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 flat size 250x150x40 mm laid in trenches as specified and as directed.
6600
-
-
Supply laying and testing cable XLPE insulated screened PVC beded,galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 25 sq mm 4 core. Including taking down old unserviceable cable any size by dismantling of all electrical connection etc all as specified and diercted.
450
-
-
All as per item no 101 above but of size 16 sq mm 4 core.
400
-
-
All as per item no 101 above but of size 10 sq mm 4 core.
50
-
-
All as per item no 101 above but of size 70 sq mm 3,1/2 core.
130
-
-
All as per item no 101 above but of size 95 sq mm 3,1/2 core.
100
-
-
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Aluminium conductor cable of size upto 50 sqmm,Indoor/Outdoor type complete all as specified and as directed.
8
-
-
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Aluminium conductor cable of size 70 to 120 sqmm ,Indoor/Outdoor type complete all as specified and as directed.Make : M-seal, Denson,
5
-
-
M&L for Marking of any size pole , Scrubing of existing rusted/unread surface of poles and prepration surfaces for marking, Marking done by two colour. numbers marking done by white colour and back side colour and shape as per direction of Engr in Charge .
150
-
-
S&F in replacement of MCCB 415 Volt 16 KA, 4 Pole 63 Amps capacity. Complete all as specified and directed by Engineer-In-Charge. Make:ABB/Siemens/Hager.
2
-
-
All as per item No. 16 above but 100A, 25KA. Complete all as specified and directed by Engineer-In-Charge.
2
-
-
Supply & fix in replacement of LED street light of 70 watt along with fixture.Make:Bajaj equivalent to Shakti/havells/Wipro complete all as specified and directed
40
-
-
S&F in Timelite Distribution Board 100 Amp 3 pole / 230 Volt Digital Time Switch including Street Light Timer assembly( 01 Nos) comprising of Digital timer- FM1 Quartz with 3 Pole ML-5 Contactor duly prewired with bypass arrangement- 02 Nos, Digital Ampere Meter conformuing to DM 3258 of Conzerv Schiender-02Nos & LED Indicating Lamp for RYB phase indicator - 01 Set complete all as specified and as directed.Make Indoasian Cat Part No- TL065DBO or equivalent to Schindler / Indoasian.
1
-
-
S&F in Digital Time Switch including Street Light Timer assembly( 01 Nos) comprising of Digital timer- FM1 Quartz with 3 Pole ML-5 Contactor duly prewired with bypass arrangement- 02 Nos Set complete all as specified and as directed by Engr-in - charge .Make Indoasian/Schinder/L&T.
4
-
-
S&F in Digital Ampere Meter conformuing to DM 3258 of Conzerv Schiender-02Nos complete all as specified and as directed by Engr-in - charge .Make Indoasian/Schinder/L&T.
3
-
-
Supply & fix in replacement of LED DRIVER for 72 watt street light fitting complete all as specified and as directed .Make:Bajaj or equivalent to CG/Philips/Wipro.
150
-
-
Supply & fix in replacement of LED SPD for 72 watt street light fitting complete all as specified and as directed .Make:Bajaj or equivalent to CG/Philips/Wipro.
150
-
-
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40mm bore medium grade 3 meter long tapers at bottom and provided 12 mm hole (staggered ) at 75 mm centre up to2.5 meter of length from bottom, burried directly in ground filled with 45 cm length alternate layer of chemical magnesium sulphaste ,charcoal and salt upto ground level connected to galvanized iron strip 32 x 6 mm as earthinglead upto 7.5 mtrs by means of nut and bolt ,check nuts and washer of galvanized iron or steel including brazing work and 40 mm dia light grade pipe for earth lead protection pipe complete all as specified and as directed incl dismentling existing unsserviciable earthing .
Note :- Test report will be provided by the contractor after completion of earthing .
2
-
-
Repair maint of winch assembly , winding of motor , junction box, winch handle, steel wire rope and replacement of aviation light complete as per requirement all as specified and as directed by Engineer- In- Charge.
Note :- Other fitment items such nut ,bolts, clamps , welding and repairs works to be included in quoted rate.
1
-
-
Supply & fix in replacement of LED Flood light of 250watt along with fixture for high mast pole.Make:Bajaj or equivalent to shakti/Havells complete all as specified and directed
6
-
-
Supply & fix in replacement of carbon bush with holder for revolving mechanism of Make: KALIN or equivalent to Shakthi/Philips complete all as specified and directed
6
-
-
Supply & fix of V belt set , both sides for revolving mechanism all as specified and directed
2
-
-
Supply & fix in replacement of LED Driver 200 watts , 230 V 50 Hz IP-66 under /over volt protection for revolving mechanism of Make: KALIN or equivalent to Shakthi/Philips complete all as specified and directed
6
-
-
Repair and maint of 0.5 HP motor by replacing old winding with copper winding, greasing of bearings , painting ,replacement of shaft and worn out parts including changing of gear box oill with oil seal as per requirements complete all as specified and directed.
1
-
-
Supply & fix in replacement of Search LED/Sodium vapour light 300 watts, focus range 800 meters 230 V , 50 Hz PF 0.95 , IP-66 protection for revolving mechanism for watch tower. Make: KALIN or equivalent to Shakthi/Philips/Wipro complete all as specified and directed
4
-
-
Supply and fix in relplacement Solar module 260 watts , voltage 30.77 (max) , current 8.45 amps (max) , open circuit voltage 38.20 amps (max), short circuit current 8.896 amps , fuse rating 15 Amps for 15KW solar plan .Make : TATA Solar complete or equvivalent Renewsolar , Looms solar , JA Solar all as specified and directed.
2
-
-
Supply and fix MC4 DC male and female connector for 15 kw solar modules complete all as specified and directed.
20
-
-
M & L in relplacement of DC copper cable 4 sqmm for connecting in series of strings and modules 15 KW solar panels complete all as specified and directed.
150
-
-
Supply and fix water proof Solar street light battery box plastic type all as specified and directed.
1
-
-
Supply and fix MS Stand suitale for 15 KW solar module mounting all as specified and designed by Engr-In-Charge .
2
-
-
Supply only in replacement of PVC weather proof, hinged door, junction box with, 240V, Neutral link and 1No MCB SP of 6 Amps, necessary fixing arrangement such as clamps, nut, bolts, etc including dismantling old unservieable junction box all as specified and directed.
Make : Sintex, or equivalent of Hensel
5
-
-
Supply and fix PVC flexible conduit 10 sq mm all as specified and directed by Engr-In-Charge .
60
-
-