Military Engineer Services Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Military Engineer Services - MES Tender

Works
Security and Emergency Services
Eprocure
Opening Date19 Jul 2024
Closing Date4 Sep 2024
Tender Amount₹ 78,50,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, installation, testing and commissioning of UL Listed Discharge hose with Manifold Check Valve for above Cyilnders, complete with Listed Adapters & Accesories as required complete all as specified and directed Engr-in-Charge.

10

-

-

... More
Supply, installation, testing and commissioning of UL Listed Electrical Actuator for Cylinder complete all as specified and directed Engr-in-Charge.

10

-

-

... More
Supply, installation, testing and commissioning of UL Listed Local Manual Actuator complete all as specified and directed Engr-in-Charge.

10

-

-

... More
Supply, installation, testing and commissioning of UL Listed Nozzles, 360 Deg / 180 Deg Throw, selection as per approved hydraulic flow calculations complete all as specified and directed Engr-in-Charge.

50

-

-

... More
Supply, installation, testing and commissioning of Warning Sign Board with Marking "GAS DISCHARGE. DO NOT ENTER". Shall Operate on 24 V DC, Driven Through Gas Release Panel complete all as specified and directed Engr-in-Charge. (for use outside room)

10

-

-

... More
Supply, installation, testing and commissioning of Warning Sign Board with Marking "GAS DISCHARGE. EVACUATE IMMEDIATELY". Shall Operate on 24 V DC, Driven Through Gas Release Panel complete all as specified and directed Engr-in-Charge. (for use inside room)

10

-

-

... More
Supply, installation, testing and commissioning of NOVEC Piping, Sch 40; ASTM A106 Gr B, as per flow calculations for the specific hazard volume and stand to hold cylinder properly. with Manifold as per NFPA 2001 Guidelines, wherever required complete all as specified and directed Engr-in-Charge.

10

-

-

... More
Supply, Installation, Testing and Commissioning of 3 zone conventional releasing fire alarm control panel that is UL Listed and FM Approved for releasing. a single zone or combination of any two zones. The LCD display is used to show the countdown timer during activation of the releasing sequence. The Panel Shall have Configurable detection delays,Configurable first stage NAC delays,Configurable releasing duration up to 5 minutes in 5 second intervals, Built-in relays for Fire, Trouble, Stage 1, Stage 2, Extract and Local Fire, Configurable releasing delays up to 60 seconds in 5 second intervals complete all as specified and directed Engr-in-Charge.

10

-

-

... More
Supply, Installation, Testing and Commissioning of System Abort Button Unit (Red) Surface. The device shall features large mushroom head push button, twist to release latching action, robust steel enclosure, Surface or single gang flush mounting complete all as specified and directed Engr-in-Charge.

10

-

-

... More
Supply, installation, testing and commissioning of Towards Hydraulic Flow Calculations for the Suppression areas, and vetting of the Software Results from the OEM Factory Engineer complete all as specified and directed Engr-in-Charge.

10

-

-

... More
Supply, Installation, Testing and Commissioning of Conventional Manual Call Point (Yellow Colour) Release Switch, Features approved to EN54-11:2001, Terminals can accommodate up to a 2.5mm solid conductor complete all as specified and directed Engr-in-Charge.

10

-

-

... More
Supply, Installation, Testing and Commissioning of Conventional Photoelectric Smoke Detector. The detectos shall have removable, High performance chamber, Automatic Sensitivity Window Verification (ASWV)- Drift compensation technology, remote indicator output, wide voltage range (9.5-30 V dc), low profile design with one piece outer cover, single fire LED-360° viewing, Approved by LPCB complete all as specified and directed Engr-in-Charge.

60

-

-

... More
Supply, Installation, Testing and Commissioning of Conventional Sounder/Strobe. The sounder shall have robust design, Low current consumption, Xenon beacon technology, Maximum 110dB(A) at 1 metre, 32 user-selectable tones, Approved by LPCB complete all as specified and directed Engr-in-Charge.

20

-

-

... More
Supply, installation, testing and commissioning of Response Indicator for Above & Below detectors complete all as specified and directed Engr-in-Charge.

20

-

-

... More
Supply installation of ISI Marked 2 core x 1.5 mm2, Multistrand Copper, FRLS Armoured cable, RED in Colour, laid on surface with GI saddle-spacers every 0.3 meters. Complete with GI Junction Box, lugs, cable compression glands, cable tags and Ferruling complete all as specified and directed Engr-in-Charge.

1500

-

-

... More
Supply, installation, testing and commissioning of CCOE Approved UL Listed Seamless Novec 1230 Cylinder and Valve Assembly, 80 Ltrs. capacity, OEM Factory filled with Novec 1230 Suppression Liquid, pressurised to 25 / 42 bar. The cylinder valave & cylinder should be PESO aproval complete all as specified and directed Engr-in-Charge. Note- Cost for Novec 1230 suppression liquid shall be measured and paid seperately in item No 02.

7

-

-

... More
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets any thickness including cover fillets etc complete all as specified and directed Engr-in-Charge.

200

-

-

... More
Material & labour for false ceiling made out of 600 x 600 x 5 to 6 mm thick ceiling board / tiles deep panel suspensor system made out of powder coated GI sheet main tee of size 23.50 x 40 x 0.63mm and cross tee of size 23.50 x 23.50 x 0.63mm and angle size 19 x 19 x 0.63mm including 4mm GI wire for suspending bolts necessary washers nut/cleats/pin hook etc. for securing frame work to ceiling to the snap grid including provn of necessary holes / cuttings for providing light/fan as required including making necessary recesses / projected pattern complete all as specified and directed Engr-in-Charge.

200

-

-

... More
Material & labour for POP false ceiling using 600 X 900 x 12 mm thick plaster of paris with Gypsum binder sheet decorative type and necessary provision for concealed type light fittings, fixed on 22 gauge GI channel grid work, main joist of size 50 x 25 mm spaced at 750 mm centre, secondary joist of size 75 X 20 mm fixed to main joists spaced at 900mm, suspended to roof members using 25 x 25 x 2 mm GI angles and fasteners @ 1.2 M C/C, including dismantling old un serviceable false ceiling, complete all as specified and directed Engr-in-Charge.

50

-

-

... More
Taking down cement or cement lime plaster, any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc including all necessary scaffolding as required and rubbishing off the premises etccomplete all as specified and directed Engr-in-Charge.

50

-

-

... More
Material & labour for Plastering 5mm thick in cement mortar 1:3 on concete surfaces as in ceiling finished even & smooth without using extra cement in ceiling complete all as specified and directed Engr-in-Charge.

50

-

-

... More
Material & labour for preparation of newly plastered surfaces of ceiling and applying two coat of oil emulsion distemper complete all as specified and directed Engr-in-Charge.

50

-

-

... More
Complete removal of existing treatment on wall surfaces by scrapping, washing & rubbing down with water and applying two coats of oil bound distemper complete all as specified and directed Engr-in-Charge.

100

-

-

... More
Material & labour for preparation of old decorated surfaces of wall and applying one coat of oil emulsion distemper complete all as specified and directed Engr-in-Charge.

50

-

-

... More
Material & labour for applying 3 mm thick wall care putty for making the surface even & smooth complete all as specified and directed Engr-in-Charge.

150

-

-

... More
Material & labour for preparation of old decorated surfaces of ceiling and applying one coat of oil emulsion distemper complete all as specified and directed Engr-in-Charge.

150

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.