Military Engineer Services Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Military Engineer Services - MES Tender

Works
Civil And Construction
Electrical and Electronics
Solar Installation and Products
Eprocure
Opening Date19 Nov 2024
Closing Date3 Dec 2024
Tender Amount₹ 29,98,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Removing excavated soft/disintegrated rock n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting points in soil complete all as specified and as directed by engineer incharge.

27

-

-

... More
M&L for cement concrete 1:4:8 type D2 using 40 mm .graded stone aggregate in foundation filling and mass concrete complete all as specified and as directed by engineer incharge.

13.5

-

-

... More
M&L for reinforced cement concrete (Design mix) M-25 using 20mm graded stone aggregate in including rafts, footings, foundation beams, plinth beams, bases for columns, basement slabs, under rammed piles and mass concrete complete all as specified and as directed by engineer incharge.

19

-

-

... More
M&L for reinforced cement concrete (Design mix) M-25 using 20mm graded stone stone aggregate as in beams, cantilevers, bressumers, lintels over 1.5m span complete all as specified and as directed by engineer incharge.

6

-

-

... More
M&L for reinforced cement concrete (Design mix) M-25 using 20mm graded stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and as directed by engineer incharge.

6.5

-

-

... More
M&L for TMT bars 10mm dia and over cut to length bent to shape required incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire annealed, not less than 0.9mm dia complete all as specified and as directed by engineer incharge.

2100

-

-

... More
S&F ditto all as per item No 09 here-in-above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and as directed by engineer incharge.

700

-

-

... More
Use & waste of form work for rough finished flat surfaces to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed by engineer incharge.

84

-

-

... More
Use & waste of form work for rough finished flat surfaces to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. (Flat,Rough finished surfaces of concrete) complete all as specified and as directed by engineer incharge.

47

-

-

... More
Use & waste of form work for Square, rectangular or polygonal rough finished flat surfaces to sides of pillars, posts, struts, piers, columns, and stanchions complete all as specified and as directed by engineer incharge.

98

-

-

... More
M&L Brickwork with fly ash bricks (old size bricks), straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete all as specified and as directed by engineer incharge.

53

-

-

... More
M&L for rendering 15mm thick on fair face of brick works or concrete surfaces of walls with CM (1:6) and finished surface even and smooth without using extra cement complete all as specified and as directed by engineer incharge.

124

-

-

... More
M&L for rendering 20mm thick ( two layers 10 mm thick each) on fair face of brick works or concrete surfaces of walls in CM (1:4) with mixing WPC (second coat plaster) @200 ml per 50 kg cement or as per manufacturers instructions and finished surface even and smooth without using extra cement complete all as specified and as directed by engineer incharge.

268

-

-

... More
M&L for two coat of cement base paint over a coat of alkali resistant cement primer on newly plastered surface including preparation of undecorated surface complete all as specified and as directed by engineer incharge.

275

-

-

... More
Preparing surfaces of wall and applying three coats of white wash complete all as specified and as directed by engineer incharge.

198

-

-

... More
M&L for broken stone or boulders hardcore of gauge not exc 63mm, deposited spread and levelled in layers n. exc 15cm thick, watered and rammed to a true surface complete all as specified and as directed by engineer incharge.

12.5

-

-

... More
M&L for 75mm thick PCC 1:3:6 type C-2 as in plinth protection including cutting grooves at every 2mtr interval and fillling with bitumin sand mix and finishing the surface even and smooth with using extra cement complete all as specified and as directed by engineer incharge.

80

-

-

... More
Spreading and levelling in layers n exc. 25 cm thick and well ramming including watering as require for floors etc complete all as specified and as directed by engineer incharge.

7

-

-

... More
M&L for 100 mm thick Cement concrete type D-2, 1:4:8 (40mm graded aggregate) as in sub base floor complete all as specified and as directed by engineer incharge.

86

-

-

... More
M&L 15 mm thick Acid resistant tiles vitreous ceramic, unglazed, set, jointed and pointed in chemical resistant mortar, resin type, in floors.over and includind 15 mm thick cement screed bed or bedding layer for floor finishes in CM 1:6 complete all as specified and as directed by engineer incharge.

44

-

-

... More
M&L 15 mm thick Acid resistant tiles vitreous ceramic, unglazed, set, jointed and pointed in chemical resistant mortor, resin type, in Dado/Skirting.over and includind 10 mm thick rendering in CM 1:4 complete all as specified and as directed by engineer incharge.

77

-

-

... More
S&F 2nd class hard wood plain solid, straight chowkats and frames wrought,frame rebated on the solid,rounded or chamfered,put together with glue pinned at joints,supplied and fix complete all as specified and as directed by engineer incharge.

0.5

-

-

... More
S&F 35mm thick 2nd class hard wood plain framed pannelled shutter (three panel) with lock rail and panel of 12mm veneered board particle board of exterior grade with commercial veneering on both faces. The size of rail and style complete all as specified and as directed by engineer incharge.

12

-

-

... More
S&F 30 mm thick skeleton / glazed shutter factory made open rebated and prepared to received glass gauge etc with sash bar, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etcsize of member of shutters as specxified in SSR part - I (2009), section 8, clause 8.24 (a) supplied and fitted to chowkath complete all as specified and as directed by engineer incharge.

7

-

-

... More
S&F for flat iron size 25mmx3mm as in hold fast including tarring or coal tar black paint conforming to Fe 410-0 or Fe 310-0 complete all as specified and as directed by engineer incharge.

13

-

-

... More
M&L for Cutting holes in exc. half brick but not exc. one brick thick walls in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and as directed by engineer incharge.

70

-

-

... More
S&F for 100mm long MS butt hinges, medium weight cold rolledcomplete all as specified and as directed by engineer incharge.

21

-

-

... More
S&F for 75mm long MS butt hinges, medium weight, cold rolled mild steel and fixed complete all as specified and as directed by engineer incharge.

28

-

-

... More
S&F for 200mm long Mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed complete all as specified and as directed by engineer incharge.

14

-

-

... More
S&F 150mm mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed complete all as specified and as directed by engineer incharge.

21

-

-

... More
S&F for 300mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and as directed by engineer incharge.

7

-

-

... More
S&F for 150mm long Mild steel pressed handles, oval type, stove enamelled black complete all as specified and as directed by engineer incharge.

14

-

-

... More
S&F for 100mm long Mild steel pressed handles, oval type, stove enamelled black complete all as specified and as directed by engineer incharge.

14

-

-

... More
S&F 3.0mm thick sheet glass frosted on one side and glazing with oil putty/wooden beads in squares not exceeding 0.5 Sqm in each pane complete all as specified and as directed by engineer incharge.

4

-

-

... More
S&F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed by engineer incharge.

8

-

-

... More
M&L for 2nd class hard wood plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails or brads sectional area exc 6 & n.exc 13 sq.cm complete all as specified and as directed by engineer incharge.

30

-

-

... More
M&L for two coat of synthetic enamel paint over one coat of pink primer to the new wood surfaces of any description including preparation of surfaces exc. 10cm width or girth primer complete all as specified and as directed by engineer incharge. .

52

-

-

... More
S&F Framed work such as grills, gratings, Gates including pintle hinges,stops, hand made sliding bolts etc., with ends of bars shouldered, welded and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290 Gde-E-165 complete all as specified and as directed by engineer incharge.

175

-

-

... More
S&F Rolled mild steel Fe 410-W (Gde- E-250) roof trusses (framed), trussed, purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc complete all as specified and as directed by engineer incharge.

1400

-

-

... More
M&L for two coat of synthetic enamel paint over one coat of red oxide primer to the new steel surfaces of any description including preparation of surfaces exc. 10cm width or girth complete all as specified and as directed by engineer incharge.

58

-

-

... More
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by engineer incharge.

140

-

-

... More
S&F Coloured Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size ( As per approved by GE) confirming to IS 15658-2006 of 60mm thickness, M-35 Grade including sand cushioning 30 mm thick below interlocking paver block incl spreading and levelling complete all as specified and as directed by engineer incharge.

42

-

-

... More
M&L Cement concrete type B1 1:2:4 ( 20mm graded aggregate) as in edges of chequired/Interlocking tile path to making slope Interlocking surface to GL complete all as specified and as directed by engineer incharge.

0.35

-

-

... More
M&L Brickwork with fly ash bricks (old size bricks), straight or curved on plan to any radius, as in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed by engineer incharge.

21

-

-

... More
M&L for rendering 15mm thick on fair face of brick works or concrete surfaces of walls with CM (1:4) and finished surface even and smooth without using extra cement complete all as specified and as directed by engineer incharge.

11

-

-

... More
M&L for point wiring (Concealed wiring) of any length using approved colour coding as per IS, with multi stranded copper conductor 1.5 Sqmm (Nominal area), single core, PVC insulated and unsheathed stranded FRLSH cable 1100 volts grade, in PVC rigid conduits heavy duty, medium grade, ISI marked (Min19/20mm dia) with valid CML No, totally concealed in wall/floor / roof /ceiling including all accessories as required complete including sunken in cast iron/MS/GI terminal box duly painted with aluminium paint inside and anticorrosive paint out side with 2.8 mm thick bakelite hylam sheet cover, ISI marked with CM/L no. for mounting switch & sockets and PVC insulated muti stranded FRLSH copper conductor 1.5 Sq.mm single core cable (Green colour) as earth conductor and connecting to common earth dolly complete all as specified and directed by Engineer in Charge for the following:-

-

-

-

... More
One light point controlled by one switch one way type

14

-

-

... More
One Ceiling fan/Exhaust fan point controlled by one switch one way type

14

-

-

... More
One 3 pin 5 Amps socket outlet point on Same board

7

-

-

... More
One 3 pin 5 Amps socket outlet point on independent board

7

-

-

... More
Notes for Item Sr No 49.01 to 49.04 - (i) Cutting in chases and pointing in brick wall/Stone Wall will be done by contractor without any extra cost. (iI) Contractor shall provide circuit wiring with 3 x 2.5 Sqmm copper wire from DB to switch board and rate for the same is deemed to be included in unit rate quoated by the contractor.

-

-

-

... More
All as per item No 49 here-in-above but with 2.5 sq mm copper conductor FRLSH (multistrand), 1100 volts grade PVC insulated, ISI marked unsheathed cable in and including concealed PVC conduit, heavy duty, ISI marked, medium grade with valid CML No not less than 19/20 mm dia with all fitting & accessories as required and including PVC insulated ISI marked, unseathed, FRLSH copper conductor cable of size 2.5 sq mm (Green Colour) as earth wire to common earth dolly all as specified and directed, for one three pin socket outlet 15 Amps

14

-

-

... More
S&F socket outlet 3pin, 5 Amps flush type (ISI Marked) controlled by one way switch complete all as specified and as directed by Engr-in-charge.

14

-

-

... More
S&F Switch piano flush type 5Amps single pole one way.

42

-

-

... More
S&F socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type (ISI Marked) controlled by one way switch complete all as specified and as directed by Engr-in-charge.

14

-

-

... More
S&F Switch piano flush type 15 Amps single pole one way.

14

-

-

... More
S&F ceiling rose, 3 terminals / PVC / Polycarbonate, isolated body complete all as specified and as directed.

28

-

-

... More
S&F Modular stepped type electronic fan regulator all as specified & directed.

7

-

-

... More
S&F LED Tube light fitting 20/22 Watt, Surface and wall mounted LED batten, Aluminium housing provided for efficient heat dissipation with polycarbonate diffuser, heavy duty driver, 20 W LED colour temp 6500k complete including all accessories internally pre-wired and including connecting up with three core sheather flexible copper conductor cable of suitable size from ceiling rose to connector of light fittings. Make - Luker - LUMOS PRIMO Aluminium Tube set-LT522 or equivalent in Crompton Cat Part No. CCS-100-20-65-HLS2-DP-NWH and Wipro Cat Part No.LL20-221-XXX-65AL1

14

-

-

... More
S&F exhaust fan with louvers, steel body, single phase, heavy duty, Metal frame, 300 mm sweep, 1400 RPM including fixing of mounting frame in the round hole cutting in the wall, by means of rugged bolts, nuts and washers etc, including three core copper conductor flexible cord of 1.0 Sqmm x 3 core of required length from ceiling rose to the porcelain connector block of the exhaust fan complete all as specified and directed. Note:- The cost of Exhaust Fan includes the cost of GI air Louvers 16 SWG deemed to be included in quoated rate contractor and nothing shall be admissible on this account.

7

-

-

... More
S&F ISI mark energy efficient Brush Less Direct Current (BLDC) ceiling fan confirming to BIS 374-2019 (upto latest amedment) with following specifications complete all as specified and directed by engineer incharge:- (a) Air delivery more than 210 CMM. (b) Service value more than 6.0. (c) BEE star rating of product: 5 (d) Size of ceiling fan in mm: 1200mm (e) No of blades: 3 (f) Input voltage: 1 Phases, 230 V, 50 HZ, AC, however product shall operate with input voltage 120V-300 V (g) Total harmonic distoration : 20% (h) Input power : 28 W (j) Blade thickness: 1.1 mm

7

-

-

... More
Sr Item No 59 herein above contd/- (k) Type of bearing: double ball bearing (l) Insulation class: B (m) Power factor: minimum 0.95 (n) Enclosure as per clause 4.6 of BIS 374-2019 latest (o) No of canopy with each ceiling fan in Nos: 2 (p) Shank thickness: as per OEM norms (q) Shackle thickness: as per OEM norms (s) Length of down road without shakle : minimum 300mm (t) Accessories: Nut, Bolt, clamp, Shank (u) Mark of each ceiling fan as per IS 8.1 of IS :374 : 2019 (upto latest amedment) (v) Manufacturer warranty: 36 months

-

-

-

... More
S&F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 amps rated busbar, 4 way Double door enclosure made up of CRCA sheet steel, RAL powder coated, IP 43 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge

7

-

-

... More
S&F MCB SP 6 to 32 Amps 240V, 10 KA breaking capacity , C curve as per IS/IEC 60898-1 2002 with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing all as specified and directed.

14

-

-

... More
S&F MCB SPN 40 Amps 240V, 10 KA breaking capacity , C curve as per IS/IEC 60898-1 2002 with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing all as specified and directed.

7

-

-

... More
Note : For Item Sl No 60 to 62 Make of DB and MCB`s shall of same make.

-

-

-

... More
M&L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to galvnised steel earthing lead wire 4 mm dia, by means of bolts, nuts & checknuts and washers etc; GI pipe 15 mm dia medium grade pipe for protection of G.I earth lead wire, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg)/transformer/LT kiosk/HT lightening arrestors etc. including GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1:2:4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with G.I 20 mm dia medium grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion including fill up the earth pit with soil for best result and removal of excavated material from the site complete all as specified and directed. Note :- Earth protection pipe & earthing lead wire upto and including 7.5 m length is deemed included in unit rate quoted by the contractor and nothing extra on this account is admissible.

7

-

-

... More
M&L for surface Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 4 Sqmm size with multistranded copper conductor, FRLSH cable drawn in including through surface conduit, including PVC conduit medium grade, heavy duty ISI marked not less than 19/20 mm dia, along any type of wall, roof, etc, with all connected fittings, fixing of conduit on surface through providing proper clamps, saddles etc. including PVC insulated unsheathed 4.0 Sqmm cable with multistranded copper conductor of green colour as contineous earth conductor cable connected to earth dolly all as specified. Note- (i) Two runs of 04 Sqmm cable with 01 run of 4 Sqmm earth wire along with white color PVC conduit shall be measured as one RM

70

-

-

... More
M&L for surface Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 6 Sqmm size with multistranded copper conductor, FRLSH cable drawn in including through surface conduit, including PVC conduit medium grade, heavy duty, ISI marked not less than 19/20 mm dia, along any type of wall, roof, etc, with all connected fittings, fixing of conduit on surface through providing proper clamps, saddles etc. including PVC insulated unsheathed 6.0 Sqmm cable with multistranded copper conductor of green colour as contineous earth conductor cable connected to earth dolly all as specified. Note- (i) Two runs of 06 Sqmm cable with 01 run of 6 Sqmm earth wire along with white color PVC conduit shall be measured as one RM

130

-

-

... More
S & F Solar Cable 2 x 4 Sqmm, single core XLPE insulated , Type-3 DC 1500 Volts, circular plain flexible copper conductor cable, PVC Insulated and UV stabalized sheathed including rigid metalic conduit, heavy duty of size not less than 20 mm ISI marked, fixing of conduit on surface through providing proper clamps, saddles including all accessories, laid in floor/ passing through after cutting plinth protection/ floor and make good of surface as existing after laying conduit etc. including shifting of existing cable drawn in conduit from existing location to new bldg/ location, providing adapter/junction box for connecting/jointing existing cable with new cable and making connection with inverter assly by providing lugs complete all as specified and directed by Engr-in-Charge. Note :-(Two runs of 04 Sqmm solar cable along with rigid metalic conduit shall be measured as one RM) .

175

-

-

... More
Taking down existing submain wiring of 2 x 4 Sqmm and 1 x 4.0 Sqmm earth wire drawn in PVC conduit from existing location and make good of surface to match with the existing complete all as specified and as directed by engineer incharge.

35

-

-

... More
M&L for shifting solar panel battery bank of any size and dimension and inverter assembly after dismentling all electrical connections from existing location (Guard room rest room ) to new battery panel room at new location near guard rest room and making all electrical connections complete all as specified and directed by Engineer in Charge.

7

-

-

... More
Supply, laying testing and commissioning of LT cable 1100 volts, XLPE insulated, screened and PVC sheathed, galvanised steel strip or wire armoured with multi stranded aluminium conductor of size 6 sqmm two core, ISI marked heavy duty including cable glands, cable lugs in LT panel/MDB in building etc to suit the cable including material and labour for all jointing/connection material as required size, cable laid in treanches/ducts/ under plinth floors passing throught pipes etc, fixed on wall complete.

75

-

-

... More
Supply and laying of 40mm outer dia, double walled corrugated DWC pipe confirming to IS-14930 Pt-II with antirodent and non flame propogating of approved colour complete withh fitting for cable protection complete all as specified and directed by engineer incharge.

60

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.