Military Engineer Services Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date21 Nov 2024
Closing Soon4 Dec 2024
Tender Amount₹ 44,00,000
Costs
EMD
₹ 88,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_679154_2Tender No
8994/E8 OF 2024-2025Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Material and labour for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including DLP Trunking of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one light point or one fan point or one call bell point controlled by one, one way switch including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, regulators or bell push and casing caping terminal box for mounting ceiling rose/ holders etc all as specified and directed. MAKE OF COPPER CONDUCTOR :- Havells/KEI/RR Kabel/Finolex
200
-
-
Description all as per item No.4 above but for one 5 amps socket point on independent board
80
-
-
Description all as per item No.4 above but for one 5 amps socket point on same board
30
-
-
Description all as per item No.4 above but for one two way light point controlled by Two, two way switches all as specified and directed.
10
-
-
Description all as per item No.4 above but cable of size 2.5 sqmm for one 16 amps switch socket (Power) point on independent board all as specified and directed.
20
-
-
Material and labour for surface submain wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit of suitable size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly and making good to disturbed surfaces all as specified and directed. NOTE :- (a) Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length. MAKE OF COPPER CONDUCTOR :- Havells/KEI/RR Kabel/Finolex
600
-
-
Description all as per item No.9 above but with cable of size 2.5 sqmm
500
-
-
Description all as per item No.9 above but with cable of size 4.0 sqmm
400
-
-
Description all as per item No.9 above but with cable of size 6.0 sqmm
300
-
-
Supply and fix 5 Amp switch piano type single pole one way all as specified and as directed. MAKE :- Honeywell/Anchor/Cona
420
-
-
Supply and fix 5 Amp switch piano type two way all as specified and as directed. MAKE :- Honeywell/Anchor/Cona
20
-
-
Supply and fix bell push piano type one way 240 volt all as specified and as directed. MAKE :- Honeywell/Anchor/Cona
10
-
-
Supply and fix socket flush type 6 amps, 5 pin, 230v all as specified and as directed.
MAKE :- Honeywell/Anchor/Cona
110
-
-
Supply and fix switch socket combination multipurpose 2-in-1 flush type 3 pin 16 amps and 3 pin 6 amps, 230v all as specified and as directed. MAKE :- Honeywell/Anchor/Cona
20
-
-
Supply and fix in repair lamp Holder insulated body with back plate for batten fitting all as specified and as directed. MAKE :- Honeywell/Anchor/Cona
200
-
-
Supply and fix in repair LED lamp 12 watt, CDL, B-22 cap, (Pin type), 230V, PF-0.95 (min) all as specified and as directed. MAKE :- Bajaj/Philips/Wipro
400
-
-
Supply and fix ceiling rose surface Bakelite three terminal all as specified and as directed. MAKE :- Honeywell/Anchor/Cona
200
-
-
Supply and fix in repair call bell electric, ding dong, AC 240 volt, 50 HZ all as specified and as directed. MAKE :- Honeywell/Anchor/Cona
50
-
-
Supply and fix in repair flush type electronic fan regulator with 5 step type,100 W, AC 240 Volts, 50 Hz all as specified and as directed. MAKE :- Honeywell/Anchor/Cona
200
-
-
Supply and fix MCB, Single Pole, 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’B” curve all as specified and directed. MAKE:- Legrand/ABB/Schneider
90
-
-
Supply and fix in repair RCBO for earth leakage, overload and short circuit protection of capacity 32 Amps 30 mA Double pole 240 voltall as specified and as directed. MAKE :- Legrand/ABB/Schneider
30
-
-
Supply and fix MCB, Four Pole, 40 to 63 amps, 415 Volts all as specified and directed. MAKE :- Legrand/ABB/Schneider
10
-
-
Supply and fix MCB distribution board,Double door, metal enclosure, SPN, 230 Volts, 4 way all as specified and directed. MAKE :- Legrand/ABB/Schneider
20
-
-
Supply and fix MCB distribution board, Double door, metal enclosure, SPN, 230 Volts, 8 way all as specified and directed. MAKE :- Legrand/ABB/Schneider
15
-
-
Supply and fix MCB distribution board, Double door, metal enclosure, SPN, 230 Volts,12 way all as specified and directed. MAKE :- Legrand/ABB/Schneider
10
-
-
Supply and fix MCB distribution board, Double door, metal enclosure, TPN, 415 Volts, 4 way all as specified and directed. MAKE :- Legrand/ABB/Schneider
15
-
-
Supply and fix vertical MCB distribution board, as MCCB/MCB incomer, IP 43 protection, Double door, metal enclosure, TPN, 415 Volts, 4 way all as specified and directed. MAKE :- Legrand/L&T/ABB/Schneider NOTE :- MCCB/MCB shall be measured and paid seperately under relevant item.
15
-
-
Supply and fix in repair inverter LED Batten 20W surface/Wall mounted LED Luminaire with opal diffuser IP20 inbuilt battery back up , PVC housing and electronic driver with high efficiency long life LED chips, including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable all as specified and directed. MAKE :- Halonix Cat No. HLB-07-20-CW-INV or its techno commercial equivalent in Wipro/C&S/Crompton
300
-
-
Supply and fix in repair Hybrid AIO Gen2 powered by solar energy and at the same time connected to the electric grid LED light 50 Watt IP 66 rating with lumen output 120 lm/watt housing made of die-cast aluminium with street optic lens and glass diffuser for uniform light distribution incl 1.5 sqmm three core copper flexible conductor cable from junction box of pole complete all as specified and directed by Engr-in-Charge. MAKE :- Philips Cat No. BRP111 LED50/757 M Solar HY or its technocommercial equivalent in Wipro/Crompton/Osram.
10
-
-
Supply and fix in repair LED batten 2 feet long, 10 watt, 230 Volts , complete with all accssories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable all as specified and directed. MAKE :- Wipro Cat No. LL20-111-XXX-65NE3 or its techno commercial equivalent in Philips/C&S.
200
-
-
Supply and fix in repair LED Bulk head luminaire 10 watt surface/ wall mounting Pressure die cast housing with IP66 protection and IK09 impact resistance, complete including connecting up to ceiling rose with 0.5 sqmm twin core copper flexible conductor cable all as specified and directed. MAKE :- Philips Cat No.WT202W LED10S NW PSU S3 PC or its techno commercial equivalent in Wipro/C&S/Crompton.
120
-
-
Supply and fix in repair High performance 24 Watt building street light delivering 120 lumen/watt with high power LED light source with IP66 protection, PDC housing and high impact resistance (IK08) polycarbonate cover luminaire complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable including one GI medium grade 25/32 mm dia bracket of total length 60 cm and fixed to wall with 2 Nos MS Clamp and fastener all as specified and directed. MAKE :- Philips Cat No. BRP330 LED24 CW R5N PC PSU S1 V1 or its techno commercial equivalent in Wipro/C&S/Crompton.
30
-
-
Supply and fix in repair wall fan 450 mm sweep, 3 speed control ,PVC body 230 volts complete all as specified and as directed. MAKE :- Usha/Bajaj/ Havells/ Crompton
25
-
-
Supply and fix in repair exhaust fan 300 mm PVC body with louvres, 230 volt complete all as specified and directed. MAKE :- Usha/Bajaj/Havells/Crompton
20
-
-
Description all as per item No.37 above but of size 200mm
15
-
-
Supply and fix in repair PVC insulated PVC sheathed round armoured copper flexible wire multistrand 4 sqmm 3 core, ISI marked. MAKE :- Havells/Finolex/RR Kabel / KEI
200
-
-
Supply and fix in repair PVC insulated PVC sheathed round armoured copper flexible wire multistrand 2.5 sqmm 3 core, ISI marked. MAKE :- Havells/Finolex/RR Kabel / KEI
200
-
-
Supply and fix in repair PVC insulated, PVC sheathed twin flat core 1100 volts grade, 6 sqmm aluminium stranded conductor (incl wire guard where required) complete all as specified and directed by Engr-in-Charge. MAKE :- Finolex/Polycab/RR cable/KEI
400
-
-
Description all as per item No. 41 above but of size 4 sqmm
500
-
-
Supply and fix meter panel Box floor/wall mounted , cubical type, compartmentalized dust and vemin proof, indoor installation IP 42 protection of suitable size , including PVC channel 25x45 mm, made out of powder coated CRCA sheet of thickness 2.0 mm having glass door to take meter reading without opening the panel with an arrangement of incoming supply to meter from TPN DB and outgoing supply from meter to distribution board (DB) with two single core PVC insulatedunsheathed 1100 volt grade multi stranded FRLSH copper conductor cable of size 6.00 sqmm (nominal area) for phase and neutral crimping with suitable size of lugs/thimbles with locking arragement complete including dismantling and taking down old unserviceable meter board of any type and making good to disturbed surfaces complete all as specified and as directed by Engineer in charge. The panel should consist of following accessories :-
(a) 63 Amp MCCB, 4 Pole -01 (incoming)
(b) 32 Amp MCB, DP - 04 (outgoing) (c) Earth Fault Relay
(d) Spreader Link
(e) Busbar and cable glands (f) Shunt coil
(g) Suitable Space for provn of fixing 4 energy meter
20
-
-
(Item No.43.00 Contd....)
NOTE :- (a) The contractor should submit the IP Test Report and Verification of short circuit withstand Test report issued by CPRI approved Panel manufacturing in respect of Metre Box. (b) The rates for refixing of energy meter in new panel are inclusive.
Make of Panel :- Any CPRI approved Panel Manufacturer.
Make of MCCB/MCB :- BCH/L&T/C&S/Legrand
-
-
-
Description all as per item No 43 above but of suitable size alongwith following accessories all as specified and directed. (a) 63 Amp MCCB, 4 Pole -01 (incoming)
(b) 32 Amp MCB, DP - 05 (outgoing) (c) Earth Fault Relay
(d) Spreader Link
(e) Busbar and cable outgoing (f) Shunt coil
(g) suitable Space for fixing 05 energy meters
NOTE :- (a) The contractor should submit the IP Test Report and Verification of short circuit withstand Test report issued by CPRI approved Panel manufacturing in respect of Metre Box. (b) The rates for refixing of energy meter in new panel are inclusive.
Make of Panel :- Any CPRI approved Panel Manufacturer.
Make of MCCB/MCB :- BCH/L&T/C&S/Legrand
20
-
-
Description all as per item No 43 above but of suitable size alongwith following accessories all as specified and directed. (a) 100 Amp MCCB, 4 Pole -01 (incoming)
(b) 32 Amp MCB, DP - 07 (outgoing) (c) Earth Fault Relay
(d) Spreader Link
(f) Busbar and cable outgoing (g) Shunt coil
(h) suitable Space for fixing 7 energy meter
NOTE :- (a) (a) The contractor should submit the IP Test Report and Verification of short circuit withstand Test report issued by CPRI approved Panel manufacturing in respect of Metre Box. (b) The rates for refixing of energy meter in new panel are inclusive.
Make of Panel :- Any CPRI approved Panel Manufacturer.
Make of MCCB/MCB :- BCH/L&T/C&S/Legrand
15
-
-
Description all as per item No 43 above but of suitable size alongwith following accessories all as specified and directed. (a) 125 Amp MCCB, 4 Pole -01 (incoming)
(b) 32 Amp MCB, DP - 09 (outgoing) (c) Earth Fault Relay
(d) Spreader Link
(e) Busbar and cable outgoing (f) Shunt coil
(g) suitable Space for fixing 09 energy meter
NOTE :-
(a) The contractor should submit the IP Test Report and Verification of short circuit withstand Test report issued by CPRI approved Panel manufacturing in respect of Metre Box. (b) The rates for refixing of energy meter in new panel are inclusive.
Make of Panel :- Any CPRI approved Panel Manufacturer.
Make of MCCB/MCB :- BCH/L&T/C&S/Legrand
18
-
-
Material and labour for Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 3 mtr long buried directly and vertically in ground with top edge at 40cm below ground level after making bore hole of size not less than 300 mm dia and 3.0 Mtr long using suitable mechanical drilling rig (for drilling near the specified location), connected with galvanised steel earthing lead of 04 mm all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2 with pit cover, funnel, wiremesh, 32 mm dia light grade GI tubing for protection of GI lead 04mm, charcoal and salt in alternate 150mm thick layers around GI earth pipe, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including demoliton of old earthing and testing of new earthing to achieve earth resistance value as per IS specification on completion.
73
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%