Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Civil And Construction
Building Construction
Eprocure
Opening Date9 Oct 2024
Closing Date5 Nov 2024
Tender Amount₹ 10,60,000
Costs
EMD
₹ 21,200Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_678851_1Bid Award Id
ViewTender No
84846 CWE PUNETender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) all as specified and directed.
8.2
-
-
Formwork to edges of concrete fair finish surface exc. 10 cm but n. exc. 20 cm wide (Horizontal or sloping) all as specified and directed.
12
-
-
All as per Ser. item No 05.00 here in before but roof beams,bressummers,lintels, cantilevers, shelves and simiar work etc all as specified and directed.
5.5
-
-
M&L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and directed.
330
-
-
All as per Ser. item No 07.00 here in before but 6mm to 8mm bars for stirrups all as specified and directed
30
-
-
M&L for reinforced cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in slabs supported on walls, beams etc complete all as specified and directed
0.82
-
-
M&L for reinforced cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in beams etc complete all as specified and directed
0.52
-
-
M & L for rendering 10mm thick in CM (1:6) on brick masonry internal surfaces of walls finished even and smooth without using extra cement all as specified and directed.
18
-
-
M&L for 15 mm thick cement plaster in CM 1:4 mixed with WPC @ 2% by weight of cementon brick or concrete surfaces finishing the surfaces even and smooth without using extra cement all as specified & directed.
122
-
-
M&L for 5 mm thick rendering in cement mortar (1:3) on ceiling and finished even and smooth without using extra cement all as specified and directed.
9
-
-
M&L for 15 mm thick rendering in cement mortar (1:4) on top of roof mixing with WPC @ 2% by wt of cement and finished even and smooth using extra cement all as specified and directed.
8.2
-
-
M&L for preparation of new plastered surfaces and applying two coats of weather proof exterior emulsion paint over a coat of primer on wall complete all as specified and as directed by Engineer-in-charge.
422
-
-
M&L for preparation of new plastered wall surfaces and applying two coats of Oil bound distemper over a coat of alkali resistance primer over a thin (1-1.5 mm) layer of wall care putty complete all as specified and directed.
18
-
-
M&L for preparation of new plastered ceiling surfaces and applying two coats of Oil bound distemper over a coat of alkali resistance primer complete all as specified and directed.
9
-
-
M&L for 20 mm thick bearing plaster on top of brick wall adjoining to roof slab in CM 1:4 mixing with WPC @ 2% by wt of cement all as specified & directed.
2
-
-
M&L for cement concrete 1:3:6 Type C-2 (using 40mm graded stone aggregate) 75 mm thick in plinth protection, laid in alternate bays not exc. 3.0m in length, finished surfaces even and smooth without using extra cement including demolition existing concrete and rubbish off the premises complete all as specified and directed.
8
-
-
M&L for moorum filling under floors or in foundations including watering and consolidation complete all as specified and directed.
1.4
-
-
M & L hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. watered and rolled/rammed to a true surface complete all as specified and directed.
0.5
-
-
M & L for 75 mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregate as sub base, complete all as specified and directed.
24.5
-
-
M & L for screed bed or bedding layer of 15 mm thick for laying floors finishes in CM 1:4 etc all as specified and directed.
4.5
-
-
M&L for Non skid ceramic coloured tiles 7 to 8 mm thick , area of each tile exc. 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match all as specifief and directed.
5
-
-
S&F aluminium powder coated three track sliding window with two glazed shutters with 4mm thick float glass ordinary quantity and one shutter of stainless steel wire mesh 0.36 mm dia wire and 1.40mm aperture including good quality of bearing handle, locks, PVC rubber lining etc complete all as specified and as directed. Catlouge numbers of Jindal company or equivalent make complete all as specified and directed. Sections of Jindal company : Three track bottom – 20957, Three track top/vertical – 20958,Handle – 20606, Interlocking – 20605, Top and bottom – 20604.
18.4
-
-
S&F Factory made 100 % solid wood plastic composite(WPC) door frame, single rebate 90 mm x 45 mm made from wood plastic composite (Single extruded process) material with density 780 Kg/ Cum and complete all as specified and directed.
5
-
-
S&F for 35mm thick flush shutters solid core construction, with block board core and plywood face panels, commercial type on both sides including second class hard wood plain cover fillets 35X6mm all around the shutters including two coat of synthetic enamal paint over one coat of pink primer complete all as specified and directed.
1.8
-
-
S & F 200 mm long aluminium anodised, barrel tower bolts of ex- truded section and fixed all as specified and directed.
2
-
-
S & F 150 mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
2
-
-
S & F 100 mm long Butt hinges, stainless steel with steel hinge pin, and fixed all as specified and directed.
3
-
-
S & F 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed all as specified and directed.
1
-
-
Supply only Integral WPC. Of approved make all as specified and directed
6
-
-
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard dense soil complete all as specified and directed.
20
-
-
M&L for machine pressed precast cement concrete coloured interlocking paver blocks, glossy rubber moulded, of triangular / Zigzag / Haxagone/any shape/design and size as approved, 60 mm thick, confoRMing to IS 15658-2006, M-35 with grey cement and pigments grade in floor/ paths/ pavement laid over and including sand cushioning laid dry to the profile including filling the joints with sand complete all as specified and as directed.
20
-
-
M&L for PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including of existing all as specified and directed.
0.2
-
-
Returning filling in, including spreading, leveling, watering and well ramming in layers n.exc 25 cm in soil all as specified and directed.
5.3
-
-
Removing excavated soil to a distance n. exc 50 m and depositing where directed at a level n.exc.1.50 mtr above the starting point all as specified and directed.
9.9
-
-
M & L for Hardcore of broken stones or boulders of guage not exc 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface all as specified and directed.
0.6
-
-
M & L for precast cement concrete Type B0 1:2:4 (12.5mm graded aggregate) louvres and jallies, 40 mm thick (measured solid), including all mouldings complete all as specified and directed.
60
-
-
Use and waste of form work to sides of pillars, posts, struts, piers, coloumns and stanchions, for rough finished surfaces of concrete complete all as specified and as directed.
50
-
-
M & L for cement concrete Type B0 1:2:4 (20 mm graded aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, all as specified and directed.
3
-
-
S & F Framed work in side hung gates( including pintel hinges, stops, hand made sliding bolts)/ grills with ornamental and intricate design, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work confoRMing to Fe. 290.Gde-E-165 all as specified and directed.
200
-
-
Dismantling two way wooden trellis work (Jafri), including taking as under of battens in trellis (posts and rails measured separately) complete all as specified and directed
26
-
-
M&L for powder coated aluminium frame for doors, windows, ventilators, partition with one or more rebates including joining cleat for fixing etc complete all as specified and directed.
315
-
-
S&F for powder coated aluminium sliding door shutters, aluminium section weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, 200 mm handles 2 Nos in each shutter, 200 mm tower bolt 01 No in each shutter , including roller/channel/necessary fittings for sliding the shutter, anodised aluminum snap beading screws etc complete all as specified and as directed.
16.5
-
-
S&F 5mm thick Sheet glass, selected quality, in squares exc. 0.5 sq. m each pane glass, each pane fixed with aluminum frame work complete all as specified and directed.
8.5
-
-
S&F stainless steel wire cloth, 0.36mm nominal dia of wire & average width of aperture 1.40mm & fixed with alluminium wire staples fixed on wood or steel frame complete all as specified & directed.
5
-
-
S&F in 8 mm thick ACP (Aluminium composite panel) Sheet of selected quality, fixed with aluminum frame work in aluminium doors including aluminium beading and neoprene rubber complete all as specified and directed.
26
-
-
S&F10mm thick toughned glass as in partitions, and similar work including cutting in any shape i.e. semicircular/ rectangler/ square exc. 3.0 sq. m each pane glass, drilling holes as required including necessary joining cleats, glazing clips, ruber neoprene packing complete all as specified and directed
10.4
-
-
Dismantling timber scantlings 40 sq. cm and over in section, in any position complete all as specified and as directed.
0.39
-
-
Supply and fix rolled mild steel section Fe 410-W(Gde-E-250) quality A as in main and cross beams, hip and jack rafters, purlins connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates all as specified and directed.
660
-
-
Dismantling of asbestos cement (corrugated,semi corrugated, etc.) sheets in roof coverings all as specified and directed.
50
-
-
S&F for 0.50mm thick pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws with two corrugation side lap complete all as specified and as directed.
50
-
-
M&L for preparation of new steel or iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and as directed.
28
-
-
M&L for Point wiring using FRLS-H PVC insulated unsheathed, multistranded copper conductor cable 1.5 sqmm drawn through and including PVC conduit of min 20 mm dia by Cutting chases for conduits and sinking's for boxes and making good to walls, floors etc for concealed conduit wiring with modular flush box metal of GI sheet minimum 1.2 mm thick (ISI Marked) with earth teRMinal for safety, flush metal GI box of required modules as per site requirement and modular plate with support frame white in colour (ISI Marked) of required modules, 3mm thick including all fittings i.e. tees, bands and junction boxes, screws etc. complete for One light/Fan point controlled by one switch 6 Amps one way using cable (1.5 Sq mm for phase and neutral and 1.5 sq mm earthing) Note:- (a) wiring shall be done by using colour coding (b) Earth wire shall be of green colour.
2
-
-
All as item No 55.00 above One 3 pin socket outlet, 5 Amp socket outlet on same board with other switches complete all as specified and as directed.
1
-
-
M&L for One 3 pin 15 Amps socket outlet independent, using FRLS-H PVC insulated unsheathed, multistranded copper conductor cable 2.5 sqmm drawn through and including PVC conduit of min 20 mm dia by Cutting chases for conduits and sinking's for boxes and making good to walls, floors etc for concealed conduit wiring with modular flush box metal of GI sheet minimum 1.2 mm thick (ISI Marked) with earth teRMinal for safety, flush metal GI box of required modules as per site requirement and modular plate with support frame white in colour (ISI Marked) of required modules, 3mm thick including all fittings i.e. tees, bands and junction boxes, screws etc. complete for power point controlled with cables, 2.5 sq. mm size (2.5 Sqmm for Phase and neutral and 2.5 Sqmm for earthing)
1
-
-
Supply and fixing modular Switch fabio classic white series/ Switch fabio classic white with indicator, ISI marked 16 AX Amps One Way switch complete all as specified and directed.
1
-
-
Supply and fixing modular socket outlet fabio series 6 Amps 3 pin universal socket with child safety shutter, Shrouded teRMinals compatible with all standard mobile chargers, ISI marked for the same board complete all as specified and directed.
1
-
-
Supply and fixing modular socket (Fabio classic white) outlet 16 Amps shuttered socket (heavy duty) 3 pin unversal socket with child safety shutter, Shrouded teRMinals, ISI marked for the independent board complete all as specified and directed.
1
-
-
Supply and fixing modular Switch fabio classic white series/ Switch fabio classic white with indicator, ISI marked 6 AX Amps One Way switch complete all as specified and directed.
3
-
-
Supply and fixing Sheet Metal enclosure double door for DBs when MCBs to be used SPN-8 Way with 200 Amp rated bus bar complete all as specified and directed.
1
-
-
Supply and fixing amp rating 240V, 10KA curve 'C' mini miniature circuit breaker (MCB) SPN and current carrying capacity 40 Amps in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
1
-
-
Supply and fixing amp rating 240V, 10KA curve miniature circuit breaker (MCB) SP and current carrying capacity 5-32 Amps in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
1
-
-
Supply and fixing modular Ceiling Ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body 50 x 65 mm surface type complete all as specified and directed.
2
-
-
Supply & Fixing only LED lights fitting 20W LED 6000K (4Ft), 220V,AC decorative box type with driver, Aluminium extruded (Intervertor tubelight fittings) holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
1
-
-
M&L for Sub Main wiring complete with copper conductor, multi stranded, FRLS, PVC insulated and sheathed, 4 Sq mm, two run 1100 volts grade, incl drawn through PVC suitable size conduit and 4 Sqmm single run for earthing complete all as specified and as directed.
10
-
-
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including theRMal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
1
-
-
Supply and fixing wall mounted fan, complete with blades (3 Nos), and accessories, 230 V, 450 mm sweep. Min air delivery 110 m³/min with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) and TheRMal overload protector (TOP) which helps in protecting the motor in case of any high voltage fluctuation complete all as specified and directed
1
-
-