Military Engineer Services Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date4 Sep 2024
Closing Date25 Sep 2024
Tender AmountRefer Documents
Costs
EMD
₹ 98,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_671565_1Bid Award Id
ViewTender No
GERD/PSN/TOKEN/23 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Material and labour for straight through joint,heat shrinkable,type,for under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE,3 core, 95 sqmm,22 KV complete all as specified and directed. by Engineer-in-charge.
6
-
-
Material and labour for straight through joint,heat shrinkable,type,for under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE,3 core, 120 to 185 sqmm,22 KV complete all as specified and directed. by Engineer-in-charge.
8
-
-
Material and labour for outdoor type end termination joint, heat shrinkable, type, for under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE, 3 core, 95 sqmm, 22 KV complete all as specified and directed by Engr-in-charge.
6
-
-
Material and labour for outdoor type end termination joint, heat shrinkable, type, for under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE, 3 core, 120 to 185 sqmm, 22 KV complete all as specified and directed by Engr-in-charge.
8
-
-
Material and labour for indoor type end termination joint, heat shrinkable, type, for under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE, 3 core, 95 sqmm, 22 KV complete all as specified and directed by Engr-in-charge.
4
-
-
Material and labour for indoor type end termination joint, heat shrinkable, type, for under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE, 3 core, 120 to 185 sqmm, 22 KV complete all as specified and directed by Engr-in-charge.
5
-
-
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for taking out/laying of HT/LT under ground cable and getting out in Soft/ loose soil complete all as specified and directed.
44.1
-
-
(b) All as per item No 10 above but Hard / dense soil complete all as specified and directed.
66.15
-
-
(c) All as per item No 10 above but Soft disintegrated rock complete all as specified and directed.
44.1
-
-
(d) All as per item No 10 above but Hard rock complete all as specified and directed.
11.03
-
-
Earth Work Excavation in trenches n.exc. 1.5 Metre wide and exc. 1.5 m and n.exc 3.0 m deep for pole foundation etc and getting out in soft disintegrated rock complete all as spcified and directed by Engineer-in-Charge.
1.6
-
-
(a) All as per item No 14 above but Hard rock complete all as specified and directed.
1.5
-
-
Returning, filling in soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as spcified and directed.
162.24
-
-
Removal of excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as spcified and directed.
3.13
-
-
Material and labour for riddled earth filling in trenches to required width at bottom and top of cable as cushioning including spreading leveling and consolidation complete all as specified and as directed. Note : Punned thickness shall only measured and paid.
39.69
-
-
Supply and lay in trench reinforced precast concrete cable cover class HV type 1, flat size 250 x 150 x 40mm for cable protection complete all as specified and directed by the Engr-in-charge
1000
-
-
Supply and lay in trenches reinforced precast concrete semi round cable cover class LV, Type I, size 1000 mm x150mm x 32mm for HT cable protection complete all as specified and directed by the Engr-in-Charge.
340
-
-
Material and labour for straight through joint,heat shrinkable,type,for HT OH AB cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE,3 core,95 to 185 sqmm,22 KV including taking down existing unserviceable joint complete all as specified and directed by Engineer-in-charge.
1
-
-
Repair and overhauling to gang operated air brake switch device upto 400 Amps,22 KV capacity including greasing/oiling of all moving contacts, replacement of nuts, washers of suitable size, unserviceable spares and jumper connections in all phases for smooth functioning of all moving contacts of GOD complete all as specified and directed. Note : (i) Contractor shall provide all safety tools like HT hand gloves, ladder, rope, safety belt, helmet etc, T&P meggar, earth tester and other necessary tools required at site.
(ii) Spares required to be replaced shall be measured and paide separately as "Supply only" and fixing charges for the same is deemed to include in the rates quoted for the items.
10
-
-
Supply only Male contact/moving contact with blade arcing horn of gang operated AB switch devices suitable for 22 KV complete all as specified and directed
6
-
-
Supply only Female contact /fix contact jaw arcing horn for gang operated AB switch devices complete all as specified and directed.
6
-
-
Supply only Tinned copper flexible jumper 200/200 Amps of suitable length
6
-
-
Supply only Post top Polymer insulators of gang operated AB switch devices complete all as specified and directed
6
-
-
Supply only Middle post Polymer insulators of gang operated AB switch devices complete all as specified and directed
6
-
-
Supply only Bottom post Polymer insulators of gang operated AB switch devices complete all as specified and directed
6
-
-
Supply only MS jumper carrier complete all as specified and directed.
6
-
-
Supply only back connector plate complete all as specified and directed.
9
-
-
Supply only GI pipe, heavy grade 25 mm dia made to shape for gang operating from ground complete all as specified and directed.
12
-
-
Repairs to drop out fuse complete of upto 400 Amps,22 KV capacity including replacement of worn out nut bolts,washers,of suitable size /unserviceable spares and jumper connections for smooth functioning of the devices complete all as specified and directed by Engr-in-charge. Note : Unserviceable spares and jumper connections replaced will be measured and paid seprately as "Supply only"
6
-
-
Supply only the following items:-
(a) Top contact/L contact for drop out fuse. complete all as specified and directed
6
-
-
(b) Lower contact for drop out fuse. complete all as specified and directed
6
-
-
(c) Post insulators of drop out fuse. complete all as specified and directed.
6
-
-
Material and labour for ACSR conductor (Ferret) jumper connections of following lengths both ends secured with suitable aluminium lugs as per site requirement encased with polythylene sleeve, RYB colours of suitable dia complete all as specified and directed for :-
a) Not exceeding 0.75 metre length.
15
-
-
b) Exceeding 0.75 metre length but not exceeding 1.5 metre length.
15
-
-
c) Exceeding 1.5 metre length but not exceeding 2.5 metre length.
15
-
-
d) Exceeding 2.5 metre length but not exceeding 3.0 metre length.
15
-
-
Supply install testing and commissioning of 22 KV outdoor type Polymer based gang operated air brake switch triple pole, suitable for verticle mounting complete with explusion fuses, GI operating rod of suitable length for operating mechanism worked from ground level complete in both OFF and ON positions, for current rating upto 200 Amps,each pole consist of galvanised steel base HT insulators as per BSS/ISS non ferrous knife and spring loaded contacts, arcing horns of adequate section to brake magenetizing current of the transformers. All ferrous parts hot dipped galvanised and non ferrous parts suitably tinned to withstand weather including taking down unserviceable AB switch complete all as specified and directed.
2
-
-
Supply and fixing in repair Polymer based dropout fuse unit complete set suitable and including for 22 KV, HT outdoor and dropout type of capacity 200 Amps including jumper connections with copper flexible designed jumper and testing and commissioning all as per the directions of Engr-in-charge
2
-
-
Supply and fixing in repair Polymer Pin type insulator of 22 KV including necessary hardware complete all as specified and directed by Engr-in-Charge.
12
-
-
Supply and fixed in repair Polymer disc type insulator, ball and socket type, white brown or green for 22KV including necessary hardware complete all as specified and directecd.
6
-
-
S&F in repair lightning surge arrestor, non linear type MCOV, 18 KV, 5 KA with all fittings bolts nuts and washers etc all as specified and directed.
1
-
-
M&L for preparation of old painted steel surface of 6/4/2 pole structure HT street light HT steel tubular poles 11 mtr long above GL/coping including cross arms,channels,Flat iron,Clamps in HT OH line by scraping with wire brush and applying one coat of aluminium paint including pole numbering all as specified and directed by Engr-in-charge for the following types:-
a) HT 6 Pole structure 11 mtrs long including channels, nut, bolts and clamps complete
4
-
-
b) HT 4 Pole structure 11 mtrs long including channels, nut, bolts and clamps complete
8
-
-
c) HT 2 Pole structure 11 mtrs long including channels, nut, bolts and clamps complete
6
-
-
d) HT pole 11 mtrs long including channels, nut, bolts and clamps complete
150
-
-
Disconnecting the Pole mounted / Platform mounted indoor /out door type transformer situated at various locations installed inside ARDE sub station 22 / 0.433 KV of 100 KVA any make and transporting to workshop for repairs / rewinding. Dismantling the transformer and accessories, removing insulating oil, taking out the core assembly, taking out the defective winding, cleaning the transformer complete internally and externally, rewinding HT/LT coil with new copper super enamelled wire / copper strip of existing size, providing new insulation, sleeves for outlet connections, ovening the complete core assembly, reassembling, including dehydration and filtration of Transformer oil to achieve desired dielectric strength, carrying out routine test, re-installation and commissioning complete all as specified and directed. The repair work also includes the routine tests i.e. IR value, High voltage test, Ratio test, short circuit test & BD value of oil of the transformer to be carried out all as directed and to the satisfaction of Engineer-in-charge.
(a) 50 to 200 KVA
1
-
-
(b) 250 to 315 KVA
1
-
-
(c) 350 to 500 KVA
Note item No 49 to 51:-
(i) Copper winding wire / strip will be measured and paid separately. (ii) Transformer oil for filtration and addtional quanties for topping up will be measured and paid separately. (iii) Credit shall be recovered for the retrieved materials under Sch of Credit. Items not mentioned in Sch of Credit shall be deposited by the contractor in th MES storeyard. (iv) Defective parts replaced will be measured and paid separately as "Supply only".
1
-
-
Supply only super enamelled copper winding wire of various gauges or existing specifications for repair and rewinding of transformers under item No. 49 to 51 primary and secondry coils including necessary class of insulation complete all as specified and directed.
Make : ISI marked as approved by Engr-in-Charge
140
-
-
Supply only DPC copper strip of various gauges or existing specifications for repair and rewinding of transformers under item No. 49 to 51 primary and secondry coils including necessary class of insulation complete all as specified and directed.
Make : ISI marked as approved by Engr-in-Charge
70
-
-
Material and labour for carrying out Lab test for acidity of Transformer oil for various Transformers and submitting test report on the format complete all as specified and directed.
4
-
-
Disconnecting the transformer outdoor type from HT/ LT system and opening carefully by draining out transformer oil upto HT/LT boxes for rectifying the leakage by replacing the unserviceable spare parts of capacity 50KVA to 750 KVA transformer, refilling the transformer oil and complete assembling after repairs including testing for any oil leakages and connecting the HT/LT system after the leakages have been rectified and tested on available electric load complete all as specified and directed. Note : Defective parts replaced will be measured and paid separately as "Supply only" here in after.
3
-
-
Supply only LT bushings with brass studs of existing specification complete all as specified and directed.
8
-
-
Supply only top cover gasket set complete all as specified and directed.
3
-
-
Supply only radiator flanged gasket 6 mm thick.
3
-
-
Supply only oil level indicator gasket set with Glass
3
-
-
Supply only HT bushing with stud for 22 KV of existing specification.
3
-
-
Supply and fixed in repair explosion vent diaphragm of suitable size to match with the existing complete all as specified and directed.
2
-
-
M&L for preparation of old painted surfaces of transformer, removing rusted scale/oil & painting of transformer with one coat of synthetic enamel paint of approved make duly Marking/ Writting MES/SM No. all as directed by Engr-in-charge for :
(a) 50 to 100 KVA capacity of transformer.
1
-
-
(b) All as per item No 62 but 160 to 250 KVA capacity of transformer.
2
-
-
(c) All as per item No 62 above but 300 to 500 KVA capacity of transformer.
6
-
-
Material and labour for lifting of serviceable transformer of capacity 100 KVA to 500 KVA, 22KV/ 0.433 KV rated voltage, from one place to other by crane and transporting to other place within 02 Km radius including placing on plinth/pole mounting and connecting up all HT/LT connections, testing and enerzising the transformer complete all as specified and directed by Engr-in-charge.
1
-
-
Testing and calibration of protective relay on 22 KV of following feeders and all auxillary relays incoming and out going feeders with control panel and control cable differential relay once in a month through authorised service engineer, Checking of instruments function and taking corrective action for improvement if found improper, taking corrective checking and operating the HT switchgear and trip circuit of HT panel/breakers/RMU for its proper functioning complete all as specified and directed.
(a) Main Receiving Station - 01 RMU, 2 Load breaker & 01 VCB
(b) ARDE B Power House - 01 RMU, 2 load breaker & 06 VCB (c) ARDE Substation No 2 - 01 RMU, 2 load breaker
(d) ARDE Substation No 5 - 01 RMU, 2 load breaker
(e) ARDE Substation of PZT - 01 RMU,2 load breaker
(f) Phanchuwati Yard - 02 2 load breaker
(g) C Substation - 01 RMU, 2 load breaker & 06 VCB
6
-
-
M&L for disconnecting, opening, draw out RMU/ VCB/LB trolley complete from its position after isolating safely from contacts of breakers for inspection, checking and re installing testing commissioning of same after carryout following repair work and replacement of unserviceable spares complete all as directed and specified by OEM.
(i) Checking of Draw out mechanism/arrangement of VCB (ii)Inspection of isolating Contacts, and decarburizing the male /female contacts, jaws complete and replacement of worn out contacts . (iii) Checking of alignment with spout and setting of contact gaps. (iv) Replacement of worn out/defective minor spares parts, lubrication of moving parts of the truck by moly grease. (v) Checking/setting of master control relay, earth fault realy and overload realy. (vi) Replacement of burnt out spring charge motor, (vii) Replacement of Closing Coil 30V DC, (viii) Replacement of tripping Coil 30V DC. (ix) Replacement of top spout with Busbar. (x) Replacement of Bottom spout with Busbar. (xi) Replacement of power pack. (xii) Also checking ON/OFF/TRIP indication and make it serviceable by necessary checking/repair/replacement of control wiring. Replacement of Push button for open and Close, micro switches, indication lamps. (xiii) Decarburizing and reinsulation of complete busbar track system complete in all respect. (xiv) Misc works deemed essential to make VCB in perfectly working order. Note : Major spare parts shall be measured and paid separately as supply only under respective items here in after, however cost of minor spares shall be deemed to be included in the rate quoted.
2
-
-
Supply only following spare parts suitable for 30 VDC/ 110VAC to be incorporated under item No 67 above :- (a) Spring charge motor single phase 110/220 Volts
2
-
-
(b) Closing Coil 30V DC
2
-
-
(c) Tripping Coil 30V DC
3
-
-
(d) Top spout with Busbar 22 KV.
2
-
-
(e) Bottom spout with Busbar 22KV.
2
-
-
(f) Power pack
3
-
-
(g) Push button for open and Close.
5
-
-
(h) Micro switches
2
-
-
(j) Indication lamps.
9
-
-
(k) Selector Switch
3
-
-
Supply and fixing 02 Nos of SMPS, input Voltage 170-270 V AC, output voltage 24 V DC with microprocessor control unit for 22 KV RMU complete all as specified and directed by Engr-in-Charge.
1
-
-
Supply and fixing of RMU protection relay for 22 KV complete all as specified and directed by Engr-in-Charge.
2
-
-
Supply and fix in repairs Potential Transformer 01 Nos of rating 200/100/50/5A, 22 KV pressure epoxy cast resin complete duly intalled, commissioned, connected and tested at site complete all as specified and directed. Make : PRAGATI, PRAYAG, KAPPA, CROMPTON, AE, Starlite Electrical
1
-
-
S & F in repairs Potential Transformer ( PT) - 01 No ratio 22000/√3 volts/110/√3 volts, VA class for PT 50/0.2, Insulation level 24/50/125 KVP specially designed all as per MSEDCL recommendations and as approved by Engr-in-Charge complete.
Make : PRAGATI, PRAYAG, KAPPA, CROMPTON, AE, L&T, Vishal or as per existing make.
Notes for item above :-
The contractor's quoted rates for the item shall be deemed to include for the following provisions also. Noting extra shall be paid on this account.
(i) The work shall be carried out under combined supervision of MES and MSEDCL (ii) It is the responsibility of the contractor to get approval of repair work from MSEDCL.
(iii) The contractor should co ordinate the work with MSEDCL authorities for testing of metering unit (KIOSK) for repair work
(iv) CT ratio of metering unit should be as per the requirement of MSEDCL at the time of commissioning of the instllation.
(vi) Testing metering unit and TOD meter shall be as directed by MSEDCL Officer.
(v) Rate quoted is inclusive of Transportation from manufacturers workshop to work site, Testing charges of MSEDCL.
1
-
-
Material and labour for primary and secondry injection testing of existing CT's set of three any type any capacity installed in VCB's 22KV located at different sites and providing authentic test results for further necessary action complete all as specified and directed.
6
-
-
Dismantling and taking down unserviceable MS cross arms bracings and supports, clamps nut bolts all as directed by Engr-in-Charge.
5
-
-
Supply, installation, commissioning and testing of numerical digital over current and earth fault relay with High set & RS - 485 port including suitable rating of CT, IDMT & definite time characteristics, last 30 trip data recording with date and time and password protection operated on 30 Volts DC/240 volts AC of any make installed in VCB panel for protection against short circuit and earth fault, testing, commissioning and submitting test report on proper format including taking out old unserveciable complete all as specified and as directed. Make : schnieder model Vamp57/ Crompton Greaves Siemens.
1
-
-
Supply and fixing in repair HT Right angle boot 22 KV rating on HT side of existing transformers for jointing HT cable complete all as specified and as directed.
1
-
-
Supply and fix power connector accessories made out of Bio metalic copper alloy galvanic corrosion free heavy duty working pressure 22 KV , enough to carry electrical load and to withstand the mechanical forces imposed during installation as well as service condition and the arrangement of bolts, bolt & washers such that the pressure is uniformly distributed over the whole contact surfaced area complete all as specified and as directed for following type of clamps:- Make : Jaipuria Brothers a) PG clamps suitable to connect conductor to conductor
6
-
-
b) Pad connector suitable to pin insulators and aluminium bus bar
6
-
-
c) T connector suitable to connect aluminium bus bar to conductor
6
-
-
d) Expansion type connector for multiple connection
6
-
-
Supply and fixing of Copper busbar suitable for 22 KV, 4/6 pole structure including Bio metalic copper alloy connectors,clamps and other connected items complete all as specified and as directed by Engr-in- Charge.
Note: Connector, clamps shall be measured and paid separately under relavent items.
8
-
-
Material and labour for Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with the top edges of plate not less than 1.5 metre below normal ground level connected to GI earth strip 32mm x 6mm by means of GI nuts, bolts check nuts and washers earth lead protected by 40mm dia GI pipe light grade and connected to main distribution board/earthing test point all as shown in electrical plate No 3 of SSR part 1 and all as specified including testing on completion. Notes : The unit rate also including for excavation, earth work in any type of strata, plain cement concrete 1:3:6 using 40 mm graded crushed stone aggregate, Type C1 pit, 40mm thick RCC 1:2:4, type B1 using 20mm graded crushed stone aggregate cover reinforced with 8mm dia TMT bars @150mm can be fencing both ways, GI funnel with GI watering pipe 20mm dia medium grade, wire mesh, protection pipe 40mm dia GI pipe light grade for earth lead upto 7.50 metre long charcoal and salt complete all as specified and directed.
4
-
-
Material and labour for Earthing complete with hot dip galvanized steel pipe in pipe electrode, outer pipe 76 mm dia medium grade and inner pipe 32 mm dia including testing. 3 metre long and having 50x6 mm terminal on inner pipe to connect earthing strip with 14 mm dia holes for nut bolts. buried directly and vertically in ground with top edge at 30 cm below ground level after making bore hole of 100 mm dia and 3.3 metre deep using suitable mechanical drilling machine (for drilling near the specified bldg) connected with galvanized steel earthing lead of 32 x 6 mm strip with minimum two Nos of GI nut, bolts and connected to test point from earthing pit. The electrode pipes should be filled with 2x 25 Kg bags of carbon based earthing compound. The compound shall be highly conductive, hygroscopic, non magnetic, non corrosive in nature and have best moisture retaining qualities! with ph value between 7-9, connected to the earthing test point, fiber reinforced plastic pit not less than 300x300 mm with pit cover, including necessary returning, filling and removal of extra soil compete all as specified and directed.
MAKE:- U-Protect/ Fast Electrode / Ashlok
4
-
-
Material and labour for Earth contunity conductor or main earthing lead fixed to wall on recessed or burried in ground or drawn in conduit/pipe fixed to poles or any other indicated situation for loop earthing as required 25mm x 4 mm size galvanised strip complete all as specified and directed.
30
-
-
Material and labour for Earth contunity conductor or main earthing lead fixed to wall on recessed or burried in ground or drawn in conduit/pipe fixed to poles or any other indicated situation for loop earthing as required 32mm x 6 mm size galvanised strip complete all as specified and directed.
40
-
-
Material and labour for 22 KV HT cable Hi- Pot Testing (High potential high voltage test) with high voltage Instrument and find out weak points in the UG XLPE cabling system for rectifying defects including submitting test report complete all as specified and directed.
3
-
-
All as per item No 95 but for Over head line
2
-
-
All as per item No 95 but for HT structure 2/4/6 poles
1
-
-
Material and labour for PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in foundations of stays and poles, copping of poles etc complete including necessary form work weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
4.5
-
-
Material and labour for PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in foundations of stays and poles, copping of poles etc complete including necessary form work weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
1
-
-
M&L for PCC 1:2:4 type B-1 by using 20mm graded crushed stone aggregate as in foundations and making good road/ foot path/ hard standing/ drain/ bldg plinth protection all as specified and directed.
1
-
-
M&L for mild steel cross arms, bracing, supports, clamps and back plates fabricated from structural steel section including nuts, bolts washers, welding, bending cold or hot , drilling holes for bolts in any shape/size as directed including painting with two coats of approved colour over a coat red oxide primer all as specified and directed by Engr-in-Charge
3
-
-
Dismantling and taking down guarding wire and removing to store for safe custody or issue under Sch of credit complete all as specified & as directed.
1
-
-
S&F pin type, porcelain,vitreous,white brown or green insulator including one galvnised mild steel spindle, two nos galvanised iron washer and one galvnised iron nut, 100mm height,65mm dia for 1100v grade complete all as specified and directed by Engr-in-charge
6
-
-
S&F in repairs cradles, hexagonal / rectangular, fabricated with galvanised steel wire 3.15 or 4 mm dia complete all as specified and directed by Engr-in-Charge.
1
-
-
Supply and errect of steel tubular swaged poles type 410 SP-55 (11 mtr long) complete with CI base plate and finial taper plug, bolts, nuts and screws including taking down the existing steel pole from existinig position as specified all as directed by Engr-in-Charge.
Note:- Earthe work will be paid and measured separately.
6
-
-
M & L for stay assembly with accessories and GI stay rod 16 mm dia 1900 mm long, stay wire 7 / 4 mm stranded galvanised including mild steel stay plate 300 mm x 300 mm x 6 mm and galvanised thimble, galvanised steel 14 mm dia 400 mm long stay bow and GI nuts, washers including loop type insulator vitreous porcelain white, brown or green big size with over all dimensions 90 mm x 140 mm clearance of hole 25.5 mm complete all as specified and shown in electrical plate no 01 of SSR Part- I including taking down old unserviceable stay assembly complete all as specified and directed by Engg-in-charge.Note: Earthwork and concrete will be measured and paid separately.
5
-
-
Cutting the tree branches which touches the LT/HT OH lines and 2.5 m away from centre line of HT/LT OH line span not exceeding 60m distance between poles by using necessary T&P items and depositing the tree branches/leaves at 30m distance away from the site all as directed.
Note : Any number of tree branches cut in one span will be measured as one length for payment
105
-
-
M&L for connect, test and commissioning of HT OH AB (air bunch) cable with aluminium conductor 3 core, 185 sqmm,22 KV all as specified and directed by Engineer-in-charge. Make : Gloster/Havells/ KEI Note : (i) Rate for manpower, T&P and necessary connected items to hang HT OH AB cable between HT pole shall be deemed to include in the rate quoted. (ii) Any damage/ loss at site during work will bear by contractor.
120
-
-
Supplying, laying, jointing, testing and commissioning 22000 volts grade, 3 core 120 Sq mm HT XLPE (Earthed) shielded core type wrapped with galvanised steel strip armoured, PVC sheathed, heavy duty, electric cables, with multistranded aluminium conductor suitable for 22 KV 3 Phase AC, 50Hz, ISI marked, laid in trenches/passing through pipe/duct/ road crossing or fixed on poles, walls with suitable size clamps made out of mild steel flat iron including jointing material such as crimping type lugs, brass cable glands, heavy duty double compression type etc., complete all as specified and directed. Note: Earthwork Excavation, sand cushioning and cable covers will be measured and paid separately.
150
-
-
Supplying, laying, jointing, testing and commissioning 22000 volts grade, 3 core 185 Sq mm HT XLPE (Earthed) shielded core type wrapped with galvanised steel strip armoured, PVC sheathed, heavy duty, electric cables, with multistranded aluminium conductor suitable for 22 KV 3 Phase AC, 50Hz, ISI marked, laid in trenches/passing through pipe/duct/ road crossing or fixed on poles, walls with suitable size clamps made out of mild steel flat iron including jointing material such as crimping type lugs, brass cable glands, heavy duty double compression type etc., complete all as specified and directed. Note: Earthwork Excavation, sand cushioning and cable covers will be measured and paid separately.
190
-
-
Supply and fixing in replacement, connect, test and commissioning of LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium multi stranded aluminium conductor heavy duty 1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following sizes including cable glands, lugs and suitable size of MS saddle clips (where ever cable laid in ceilings/walls without cable duct) complete all as specified and directed by the Engr-in-Charge for the following :- Notes : (i) Excavation, sand cushioning, brick will be measured and paid separately (ii) Cost of jointing material e.g. lugs, glands thimbles, nut bolt and washers shall include in quoted rates.
(a) 16 Sq mm 4 core
150
-
-
Material and labour for GI tube, light grade with and including necessary fittings, complete, fixed to walls, pole ceiling or laid in trenches for cable protection complete all as specified and directed for the following size of pipe of :- NOTE :-
(Excavation and earth work where required shall be measured separately. MS Clamps for fixing on wall / pole , etc are included in the unit rate). (a) 150 mm bore
18
-
-
(b) 80 mm bore
6
-
-
(c) 40 mm bore
6
-
-
M&L for cutting of roads/ plinth of width n.exc 250mm and depth n.exc 250 mm complete all as specified and directed.
6
-
-
Supply only fuse wire made of standard tinned copper core suitable for 22KV 5Amp to 100 Amp complete all as specified and directed.
6
-
-