Central Railway Tender

Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.

Central Railway - CR Tender

Goods
Machinery and Tools
Ireps
Opening Date13 Dec 2023
Closing Date12 Jan 2024
Tender Amount₹ 1,67,30,406.27 
Notes
Download

Costs

Summary

Electrical Trd Portion In Upgradation/ Augmentation Of Coaching Rolling Stock Maintenance facilities At Gcmc/pa

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
3 (i) Fabrication,galvanization and supply only of K-series, B-series, T-series,G-series, S-series mast/portals- Uprights.

21.5

89413

1922382.08

... More
3 (iii) Supply only of small part steel

6

85829

514975.56

... More
4 a (i) Erection of K/B/G/T/ S- Series cantilever mast, mast of head span/uprights of D/G type Portals - manually

30

11943

358290.6

... More
4 b (ii) Erection only of small part steel

9

12430

111875.58

... More
4 c Supply of single guy rod assembly

18

7471

134494.92

... More
4 c Erection of single guy rod assembly

18

2017

36309.24

... More
6 d (ii) Erection of suspension arrangement with 9 tonne insulator for 129 sq.mm/150 sq mm single catenary/feeder/jumper wire.

15

1337

20065.65

... More
7.Supply of materials for termnation of OHE. ii) For 125 sq mm/129 sq . mm main aux catenary/feeder wire

12

13669

164037.12

... More
7.Erection of materials for termnation of OHE. ii) For 125 sq mm/129 sq . mm main aux catenary/feeder wire

12

2171

26063.28

... More
7 Supply of materials for termnation of OHE. iv) For 193 sq. mm contact wire

12

13172

158071.44

... More
7 Erection of materials for termnation of OHE. iv) For 193 sq. mm contact wire

12

2160

25923.36

... More
8(a) i Supply of 9 tonne cut in insulator: For 193 sq. mm contact wire

8

8342

66737.6

... More
8(a) i Erection of 9 tonne cut in insulator: For 193 sq. mm contact wire

8

1235

9887.68

... More
8 (a) iii Supply of 9 tonne cut in insulator: For 125 sq mm/129 sq mm/ 242 sq.mm catenary wire/feeder wire

8

8362

66898.72

... More
8 (a) iii Erection of 9 tonne cut in insulator: For 125 sq mm/129 sq mm/ 242 sq.mm catenary wire/feeder wire

8

1235

9887.68

... More
8 (b) Supply of a 25 KV post insulator

8

9896

79174.16

... More
8 (b) Erection of a 25 KV post insulator

8

513

4104.32

... More
11 (ii) Supply of dropper and dropper adjustment: For AC insulation on newly erected structure (All new droppers/ fittings in one span)

45

14113

635100.75

... More
11 (ii) Erection of dropper and dropper adjustment: For AC insulation on newly erected structure (All new droppers/ fittings in one span)

45

3649

164245.5

... More
12 Supply of jumpers: 12 (I) 105 IOL in-span jumper for 2 wire system

10

5221

52215.6

... More
12 Erection of jumpers: 12 (I) 105 IOL in-span jumper for 2 wire system

10

296

2968

... More
12 Supply of jumpers ; 12 (ii) 105 G Jumper

6

18635

111815.16

... More
12 Erection of jumpers ; 12 (ii) 105 G Jumper

6

3549

21299.64

... More
14 Adjustment of OHE; 14 (i) Supply: Formation of new (IOL) at SP/SSP/TSS /NeutraI section.

4

35779

143116.96

... More
14 Adjustment of OHE; 14 (i) Erection: Formation of new (IOL) at SP/SSP/TSS /NeutraI section.

4

12073

48293.6

... More
15 Bonding with 50x6 mm M.S.flat : 15 (i) Supply of a structure bond.

40

636

25440

... More
15 Bonding with 50x6 mm M.S.flat : 15 (i) Erection of a structure bond.

40

430

17214.4

... More
15 (ii) Bonding with 50x6 mm M.S.flat : Supply of longitudinal bond

10

465

4659.7

... More
22 (b) Dismantling of Structures: 22( b) I Dismantling/cutting and transportation of mast/portal/anchor structures and their transporatation to Railway's nominated Store.

10

5618

56180

... More
30 (a) Supply of retro reflective type number plate

40

614

24592

... More
30 (a) Erection of retro reflective type number plate

40

72

2883.2

... More
Dismantling of OHE termination assembly

4

591

2367.76

... More
Dismantling of guy rod assembly

4

395

1580.96

... More
Breaking of foundation.

20

3243

64866.4

... More
Supply of standard bracket assembly suitable for 125 sq mm catenary wire and 193 sq mm contact wire . It includes load transfer of standrad bracket from existing bracket assembly.

50

21862

1093125

... More
Erection of standard bracket assembly suitable for 125 sq mm catenary wire and 193 sq mm contact wire . It includes load transfer of standrad bracket from existing bracket assembly.

60

3355

201357.6

... More
Supply of Provision of power block working limit board

5

1532

7661.4

... More
Erection of Provision of power block working limit board

5

102

510.75

... More
Transporation & erection of 160 Sq mm copper feeder/jumper wire

0.5

22308

22308.67

... More
Erection of Anticreep wire catenary arrangement with 125 sqmm catenary wire for regulated type OHE (Wire will be supplied by Railway)

1

6219

6219.02

... More
Supply of 25KV double pole Isolator 1250/1600 Amp.

4

166951

667806.72

... More
Erection, testing and commissioning of 25KV double pole Isolator1250/1600 Amp.

4

13355

53421.4

... More
Supply of Integral lock for Isolators with 03 nos key

8

1268

10151.76

... More
Supply of 193-129/105/150/160( FM -15 PG)

16

460

7363.2

... More
Supply of P.G.Clamp (1050-3) complete assembly for 150/160 sq mm .

10

319

3190

... More
Supply of PG clamp 125/160 sq mm

20

1124

22493.2

... More
Supply of splice Clamp assembly for 193 sq,mm. Contact Wire

10

1947

19470

... More
Supply of splice for 125 sq mm catnary wire

10

1901

19017.6

... More
Splicing & extention of anchored over head equipment

10

4243

42430

... More
Supply without insulator materials for termination of double overhead equipment conductor

6

9258

55552.2

... More
Erection of materials for termination of double overhead equipment conductor

6

1233

7402.56

... More
Design & Drawings of SP with supply of drawings.

-

-

67381.82

... More
Cement concrete for foundation & plinth in other than hard soil & rock. (Foundation should be M- 15 type as per IS-456, i.e ratio 1:2:4, cement quantity per Cu.M. of foundation = 6.5 bags of 50 Kg each)

-

-

60820

... More
Cement concrete for foundation & plinth in hard soil.(Foundation should be M-15 type as per IS- 456, i.e ratio 1:2:4, cement quantity per Cu.M. of foundation = 6.5 bags of 50 Kg each)

-

-

66560

... More
Cement concrete for foundation & plinth in rock (Foundation should be M-15 type as per IS-456, ie; ratio 1:2:4, cement quantity per Cu.M. of foundation = 6.5 bags of 50 Kg each).

-

-

426850

... More
Reinforced cement concrete for cable trench. (M-15 type as per IS-456, i.e ratio 1:2:4, cement quantity per Cu.M. = 6.5 bags of 50 Kg each)

-

-

81766.9

... More
Supply & erection of cable trench covers.

-

-

31662.4

... More
Brick work for compound wall

-

-

48425.1

... More
Plastering of brick work

-

-

1157.9

... More
Supply and erection of galvanized fabricated steel work for gantry, supporting structure & SPS

-

-

712278

... More
Supply, erection, testing and commissioning of of 25KV single pole vacuum circuit breaker with accessories of capacity 1600 Amps

-

-

940704.88

... More
Supply, erection, testing and commissioning of 25 KV current transformer 1500/750/5 A Dual core PS class

-

-

297028.62

... More
Supply, erection, testing and commissioning of 25 KV potential transformer 25 KV/110 V type -II

-

-

211537.34

... More
Supply, erection, testing and commissioning of 25 KV double pole isolator 1600 A

-

-

360614.06

... More
Supply, erection, testing and commissioning of extra for interlocking between isolator and circuit breaker

-

-

14007

... More
Supply, erection, testing and commissioning of 42 KV lightening arrestor line type with surge monitor

-

-

128268.42

... More
Supply, erection, testing and commissioning of 25 KV pedestal insulator

-

-

24125.32

... More
Supply, erection, testing and commissioning of tubular aluminium busbar 50 x 39 mm dia

-

-

44004

... More
Supply, erection, testing and commissioning of rigid bimeallic terminal connector suitable for 50 mm dia Al tubular busbar to terminal pad of 25 KV isolator/CT (ID 11090)

-

-

11408.15

... More
Supply, erection, testing and commissioning of 25 KV system rigid bus splice connector to suit 50 mm OD Al tube on both ways (ID 11180 )

-

-

12651.15

... More
Supply, erection, testing and commissioning of 25 KV system Tec connector to suit 50 mm OD Al. tubular bus bar (ID 11150)

-

-

12693.95

... More
Supply, erection, testing and commissioning of rigid connector on SI to suit 50 mm OD AL bus and 7 mm dia wire (11200)

-

-

8451.3

... More
Supply, erection, testing and commissioning of sliding clamp for 50 mm OD Al busbar (ID 11190)

-

-

8429.3

... More
Supply, erection, testing and commissioning of PG clamps for 150 sqmm feeder wire to 150 sqmm jumper wire

-

-

8012.7

... More
Supply, erection, testing and commissioning of connector for 150 sqmm feeder wire to 160 sqmm jumper wire

-

-

8229.35

... More
connector for 160 sqmm jumper wire.

-

-

7628

... More
Supply, erection, testing and commissioning of connector for 160 sqmm jumper wire to 193 sqmm contact wire

-

-

8012.75

... More
Supply and erection of connector RI No. 11120 in TSS

-

-

11127.4

... More
Supply, Erection, testing and commissioning of 9 Tone Insulator at anchor post of cross feeder and along track feeder alongwith accessories

-

-

14833.24

... More
Supply, erection, testing and commissioning of 9 Tone Insulator at suspension point of cross feeder and along track feeder 150 sqmm alongwith accessories

-

-

32633.16

... More
Supply, erection, testing and commissioning of Earth Electrode as per IS: 3043 & RDSO specification latest

-

-

60241.1

... More
Supply, erection, testing and commissioning of 75 x 8 mm MS strip laid in ground

-

-

5888.1

... More
Supply, erection, testing and commissioning of 75 x 8 mm MS strip laid Exposed

-

-

5561

... More
Supply, erection, testing and commissioning of 50 x 6 mm MS strip laid in ground

-

-

18920.4

... More
Supply, erection, testing and commissioning of 8 SWG GI earth wire

-

-

209.36

... More
Supply and spreading of good quality ballast in the switch yard as per RDSO specification.

-

-

222556

... More
Supply, transporatation and erection, testing and commissioning of control cables (fire retardent) For CB of size: 7 x 2.5 sqmm Cu.

-

-

22636

... More
Supply, transporatation and erection, testing and commissioning of control cables (fire retardent) For CB of size: For CT 2 x 4 sqmm cu

-

-

26954

... More
Supply, transporatation and erection, testing and commissioning of control cables (fire retardent) For CB of size: For 240 V heater ckt 2 x 4 sqmm cu

-

-

6738.5

... More
Supply, transporatation and erection, testing and commissioning of control cables (fire retardent) For CB of size: For PT 2 x 2.5 sqmm Cu

-

-

11859

... More
Supply, erection, testing and commissioning of galvanized fencing Upright

-

-

18943.17

... More
Supply, erection, testing and commissioning of galvanised Fencing Panel

-

-

131630

... More
Supply, erection, testing and commissioning of galvanised Anticlimbing Devices

-

-

26432.25

... More
Supply and erection 8 inch (200 mm) DIA. RCC hume pipe.

-

-

545.1

... More
Supply, Erection, testing and Commissioning of Control & relay panel for two feeder CB with control equipment as per RDSO specification no TI/SPC/PSI/PROTCT/6071 (02/15) or latest

-

-

3240792

... More
Modification/Up gradation in the existing SCADA system for configuration, hooking of additional RTU's if required.

-

-

185600



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.