Airports Authority Of India Tender
Search from over 12139+ business opportunities that have been announced from the biggest Mahatenders, e tender Maharashtra, Maharashtra government tenders, and the Online Tender Notices posted on Maharashtra e tenders till date. Find opportunities that have come in from the multiple corporations, Maharashtra government departments, State PSUs, and Private companies from the state.
Airports Authority Of India - AAI Tender
Civil And Construction
Eprocure
Opening Date8 Mar 2022
Closing Date4 Apr 2022
Tender Amount₹ 92,85,542 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 2,23,423Document Cost
₹ 1,180Tender Fee
Refer Documents
Summary
Bi-annual Operation And Maintenance Contract For The E And M Installations, Wtp Etc. At Birsi Airport, Gondia For The Year 2022-24
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_AAI_108830_1Bid Award Id
ViewTender No
AAI/Gondia/E-E/2021-22/NIT-07Tender Authority
Airports Authority Of India ViewPurchaser Address
-Website
http://https://www.aai.aero/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
2nd Year
10
-
-
Rewinding Servicing, repairing of Exhaust fan/ Air Circular fan of size upto 450 mm sweep i/c replacement as bushes/bearings if required and to & fro transportation etc complete as required. (Dismantle Material belongs to contractor)
-
-
-
1st Year
5
-
-
2nd Year
5
-
-
Rewinding of the motors (Capacity from 3 HP and upto 5 HP), Which are suitable to operate on 415V, 50Hz, 3Ø AC supply, with suitable gauge copper wire i/c warnishing, bearing if required etc as required i/c transportation from site to workshop & back to site. (Dismantle Material belongs to contractor).
-
-
-
1st Year
2
-
-
2nd Year
2
-
-
Repair and rewinding of submersible pump motor set up to 5 HP capacity. Job include transportation of motor dismantling and rewinding with the same gage insulated copper wire including replacement of all the internal worn out/defective parts i.e bushes, impellers, sleeves, upper and lower bush sets, thrust bearing, oil seals, rotor grinding and balancing, assembling, testing, transportation etc. complete as required.
-
-
-
1st Year
3
-
-
2nd Year
3
-
-
Lifting & Lowering of submersible pumps of various capacities (up to 5 HP) due to defect in existing pump / pump choked in existing borewell on urgent basis within a short notices including connection of cables jointing of cables etc. with successful testing &commissioning complete as required.
-
-
-
1st Year
3
-
-
2nd Year
3
-
-
Execution of work as per CPWD DSR 2018 (E&M).
NOTE: The firm has to quote/upload the percentage above / below (+/- % on the quantity mentioned against BOQ item No. (7) directly in the form of multiplying factor in the rate column as clarified below: For example, “if agency desired to quote 5% above on CPWD DSR-2018 (E&M) rates, the rate column shall be filled as 1.05. If agency desired to quote to 5% below on DSR-2018 rates, the rate column shall be filled as 0.95.”
1
-
-
Inspection, Servicing and Testing of 800A capacity 11 KV Vaccum Circuit Breakers (Make - CGL) including CTS PT wiring, other carrying out tests & preventive maintenance through authorised service agent and submission of test reports complete job as per attached technical specification.
-
-
-
1st Year
3
-
-
2nd Year
3
-
-
Inspection, servicing, setting, calibration and testing of IDMT relays, Make - Easun Reynode, Model - 04574 (set of 2 over current + 1 earth fault) i/c carrying out tests & preventive maintenance through authorised service agent and submission of test reports complete job as per attached technical specification.
-
-
-
1st Year
3
-
-
2nd Year
3
-
-
Inspection, servicing, setting, calibration and testing of auxiliary and tripping relays including carrying out preventive maintenance through authorised service agent and submission of test reports complete job as per attached technical specification.
-
-
-
1st Year
3
-
-
2nd Year
3
-
-
Inspection, servicing & testing of following Air circuit breakers of Capacity up to 1250A including carrying out the testing and preventive maintenance through authorized service agent and submission of test reports complete job as per attached technical specification.
-
-
-
1st Year
5
-
-
2nd Year
5
-
-
Dehydration and filtration of transformer oil at site (Transformer Make: Indotech, Capacity 500 KVA, Oil Capacity 1050 Ltrs.) including testing the BDV and acidity before and after testing, topping of oil and submission of test reports etc. as required for following Transformers complete job as per attached technical specification.
-
-
-
1st Year
2100
-
-
2nd Year
2100
-
-
Supply of transformer oil of IS: 335/1980 ammended upto date with test report as required.
-
-
-
1st Year
75
-
-
2nd Year
75
-
-
Recharging of pebble and graded sand filter of capacity 10,000 ltrs / Hr. by replacing the sand from existing pressure vessel of size 700 mm dia, 2000 mm height etc. as per site reqirement (NIATAM).
-
-
-
1st Year
450
-
-
2nd Year
450
-
-
Recharging of pebble and graded sand filter of capacity 3000 ltrs / Hr. by replacing the sand from existing pressure vessel of size 400 mm dia, 1250 mm height etc. as per site reqirement (Airport & AAI Colony).
-
-
-
1st Year
450
-
-
2nd Year
450
-
-
Recharging of activated carbon filtration system of capacity 10,000 ltrs./Hr. replacing activated carbon from existing pressure vassel of size 800 mm dia, 2000 mm height etc. as per site requirement (NIATAM).
-
-
-
1st Year
450
-
-
2nd Year
450
-
-
Recharging of activated carbon filtration system of capacity 3000 ltrs./Hr. replacing activated carbon from existing pressure vassel of size 400 mm dia, 1250 mm height etc. as per site requirement (Airport & AAI Colony).
-
-
-
1st Year
325
-
-
2nd Year
325
-
-
Rewinding and servicing of 370W, 0.5HP, Single phase Motor which are suitable to operate on 230V, 50Hz, AC Supply, with suitable gauge copper wire including warshining, bearing etc. as required. Including transportation from site to workshop & back to site. (include less rebate of dismantled copper wire)
-
-
-
1st Year
3
-
-
2nd Year
3
-
-
Supply of 40W, 4 Pin, Single Ended Tubular Ultra Voilet Tube Lamp suitable for single phase 230V, 50Hz, AC Supply.(Similar to Model TUV 36T5 HE 4P SE, Make Philips)
-
-
-
1st Year
15
-
-
2nd Year
12
-
-
Supply of 40 Watt, Electronic Ballast for TUV Fixture Suitable for Single Phase, 240Volt, 50Hz, AC supply (Similar to Model No. HF-P 158TL-D III 220-240V 50/60 Hz, Make Philips)
-
-
-
1st Year
12
-
-
2nd Year
12
-
-
Supply of 40 Watt, 4 Pin, T-5 TUV Lamp Holder suitable for Single Phase, 240Volt, 50Hz, AC supply (Similar to Model No. G10Q 4-PIN, Make Philips )
-
-
-
1st Year
12
-
-
2nd Year
12
-
-
Supply of Aluminium Sulfate (Alum) suitable for water treatement. (KAI(SO4)2-12H2O)
-
-
-
1st Year
100
-
-
2nd Year
100
-
-
Supply of Calcium oxychloride (Bleaching powder) suitable for disinfecting of drinking water. (CAOCl2)
-
-
-
1st Year
100
-
-
2nd Year
100
-
-
Spray Painting of sand filter cylinder,activated carbon filter cylinder and Tube setteler applying two coats of syntetic enamel paint of approved make including cleaning of surface by sand paper and thereafter applying red oxide to obtain even shade etc complete as per satisfaction E-I-C as required.
-
-
-
1st Year
3
-
-
2nd Year
3
-
-
Providing and placing on terrace (at all floor levels) polyethylene water of 5000 Ltr. storage capacity tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes with fittings and the base support for circular tank.
-
-
-
1st Year
1
-
-
2nd Year
1
-
-
Evaluation Notes How It Works ?