Get tender documents at just ₹200 per tenderKnow More
Search made simple for latest tendersNo hidden charges. No keyword restrictionsExplore Our Plansor Pay Per Tender

Municipal Corporation

  • Opening Date

    07 Oct 2019

  • Closing Date

    17 Oct 2019

  • Tender Amount

    Refer document

  • EMD

    -

Are you Looking for Joint Venture Partners, Contractor Consortium, Project Financiers for this tender?
We will help YOU to find the right match for FREE!
Summary

Fixed Clean Agent Gas Based Fire Suppression System

Are you looking for Materials and Services for this tender?
We will help YOU to find the right partner for your needs for FREE!
BOQ Items

No BOQs Available

Bid Number: GEM/2019/B/380112 Dated: 07-10-2019 Bid Document Bid Details Bid End Date/Time 17-10-2019 15:00:00 Bid Life Cycle (From Publish Date) 90 (Days) Bid Offer Validity (From End Date) 30 (Days) Ministry/State Name Madhya Pradesh Department Name Urban Development And Environment Department Organisation Name Indore Municipal Corporation Indore Office Name Indore Total Quantity 5 Item Category Fixed Clean Agent Gas based Fire Suppression System Average Turnover (Last 3 Years) 5 Lakh (s) OEM Average Turnover (Last 3 Years) 50 Lakh (s) Experience with Government Required 3 Year (s) MSE Exemption For Years Of Experience And Turnover Yes Startup Exemption For Years Of Experience And Turnover Yes Document required from seller OEM Annual Turnover Bid to RA enabled No Note: 1. OEM Turn Over Criteria: The minimum average annual financial turnover of the OEM of the offered product during the last three years, ending on 31st March of the previous financial year, should be as indicated in the bid document. Documentary evidence in the form of certified Audited Balance Sheets of relevant periods or a certificate from the Chartered Accountant / Cost Accountant indicating the turnover details for the relevant period shall be uploaded with the bid. In case the date of constitution / incorporation of the OEM is less than 3 year old, the average turnover in respect of the completed financial years after the date of constitution shall be taken into account for this criteria. Fixed Clean Agent Gas Based Fire Suppression System ( 5 pieces ) Technical Specifications * As per GeM Category Specification 1 / 6 Specification Specification Name Values Bid Requirement (Allowed Values) GENERIC Clean Agent Gas based Fire Suppression System suitable upto 2 metre cube volume Designed to fight fires that occur in the enclosed space of electric panels/closed cabinets/Racks The system's split second detection and activation ensures that the fires are killed in the nascent stage inside the most vulnerable spaces * Types of Electrical or Server Cabinets (Construction) Open Cabinet with natural Airflow * Type of Clean agent with zero ODP(ozone depleting potential) as per NFPA 2001 to be used for fire suppression - * Clean Agent listing UL * CONSTRUCTIONAL Container (Containing the clean agent) BS EN 3-8 * Electrical non conductive Clean Agent Type Yes * Clean agent Capacity of cylinder in Kg 2 * Length of Heat Sensing Tube (HST) made of special modified polymide (PA) in (meter) approved by LPCB / UL LISTED 20 * Internal Diameter of Heat Sensing Tube 4mm * Out side diameter of heat sensing tube 6mm * Prepressurised Tube Heat Sensing Tubing should be pressureized with dry nitrogen gas confirming to IS: 1747 and connected to an extinguishing agent container via a pressure release valve. * Pressure Valve Direct low pressure type with inbuilt * 2 / 6 pressure gauge, integrated ball valve for open / close within the valve body. Reed switch to monitor the valve position using the reed switch relay to indicate valve open/closed position With * Number of outlets to connect the heat sensing tube Two * Valve operation Pneumatic * Monitoring Panel An audio visual monitoring panel Micro controller based design to check the health of the system and the pressure in the tube * Power back up for Monitoring Panel 12V, 7.2 Ah SMF batteries (2 Nos) * Indication on Monitoring Panel Ac Power ON, system ON ,system discharge, valve closed/open,Pressure Healthy , Battery Low indication by LED indicator * Third Party Intigration facility to intigrate with other fire safety device like smoke detection system panel etc Yes * Electric Buzzer 50 dB piezo electric buzzer * Pressure switches to sense the drop in pressure Yes * Option to connect upto 4 systems in one panel Yes * If not connect 4 system in one panel please declare - * Suitable valve for closing & releasing Yes * Straight connectors/ elbow conn

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.