Get tender documents at just ₹200 per tenderKnow More
Search made simple for latest tendersNo hidden charges. No keyword restrictionsExplore Our Plansor Pay Per Tender

Most viewed tenders

Recently Added tenders

Ministry Of Coal

  • Opening Date

    08 Oct 2019

  • Closing Date

    19 Oct 2019

  • Tender Amount

    Refer document

  • EMD

    -

Reminder

Follow

Download
Are you Looking for Joint Venture Partners, Contractor Consortium, Project Financiers for this tender?
We will help YOU to find the right match for FREE!
Summary

Led Luminaire (for Road And Street Lights)

Are you looking for Materials and Services for this tender?
We will help YOU to find the right partner for your needs for FREE!
BOQ Items

No BOQs Available

Bid Number: GEM/2019/B/380173 Dated: 08-10-2019 Bid Document Bid Details Bid End Date/Time 19-10-2019 11:00:00 Bid Life Cycle (From Publish Date) 90 (Days) Bid Offer Validity (From End Date) 75 (Days) Ministry/State Name Ministry Of Coal Department Name Materials Management Organisation Name Northern Coalfields Limited Office Name Singrauli Total Quantity 150 Item Category LED Luminaire (For Road and Street Lights) Experience with Government Required 3 Year (s) MSE Exemption For Years Of Experience And Turnover No Startup Exemption For Years Of Experience And Turnover No Document required from seller Certificate (Requested in ATC),OEM Authorization Certificate Bid to RA enabled Yes LED Luminaire (For Road And Street Lights) ( 150 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) STANDARDS LED Luminaire conformity to IS:10322/Part 5/Section 3/2012 latest and IS: 16107 (Part 2/Sec 1):2012 latest Yes * Photo biological safety of LEDs used shall be as per IS:16108/2012 Yes * 1 / 8 (exempt group) Types of LED Luminaire as per the IS: 16107(Part-2/ Sec.-1)/2012 Type B * Types of LED Modules as per the IS:IS: 16103(Part-2)/2012 Type 3 * LED Rating (in Watts)/System Wattage/Rated Power 70W 70W Luminaire System Efficacy (Lumen/watt) >/= 100 Lm/Watt * Ingress Protection (IP Rating) as per IS:10322 (Part 1):1982 latest IP66 * Warranty for free replacement (in years) 5 5 ELECTRICAL EFFICIENCY Input operating Voltage range and frequency 90 to 300 Volts AC at 50 Hz+/-2 * Automatic Higher Cut off voltage above 300 volt Yes * Rated voltage 230 V AC 50 Hz * AC Power Factor at full load ≥ 0.95 * Driver Efficiency (in %age) Upto 100W: ≥85%, Above 100W: >/=90% Yes * Total Harmonics Distortion ≤ 10 * "The total circuit power shall not be more than 110 percent of the value declared by the manufacturer (as per Cl. 8 of IS:16104:2012 lates)" Yes * OPTICAL LED chip Efficacy ≥130 Lm/Watt * Colour temperature 6000+/-500K * Working life for LED (Minimum 50,000 burning hours as per LM-80 and LM 21 reports) Yes * 2 / 8 Colour Rendering Index(CRI) ≥70 * LED Beam Angle ≥120 * Optic lense materal (UV stabilised) Poly carbonate lense * THERMAL MANAGEMENT Heat sink should be die- cast aluminium along with sufficient heat sink fins to dissipate heat effectively Yes * Junctiojn / Soldering point temperature shall not exceed 85 deg.c as per LM 80 report Yes * Capacitor shall be rated for a temperature of 105 deg. celsius or better Yes * Operating temperature range -10 deg C to +55 deg C -10 deg C to +55 deg C Operating Humidity Range 10 % to 95% RH * PROTECTION Short circuit Protection Yes * Over load protecton Yes * Over Voltage protection Yes * Reverse polarity Yes * High voltage test (1.5 KV for one minute between supply terminals and body of the unit) Yes * Insulation resistance between earth and current carrying part >100 M Ohm * The luminaire shall be protected against surges and transients ( Internal) >/=4KV * The luminaire shall be protected against surges and transients of >/=10KV (External) Yes * CONSTRUCTIONAL The Luminaires casing/housing (single piece housing) shall be pressure die casted aluminium alloy with higher thermal conductivity Yes * 3 / 8 The luminaire body must be corrosion resistant powder coated Yes * All fastners must be of stainless steel Yes * Protection of the entire housing (both LED section and driver section) as per IS:10322 (Part 1):1982 latest IP66 * Extruded silicon loop gasket shall be provided in the lantern body to ensure a weather proof seal between the UV Glass cover and the metal housing to exclude the entry of the dust, water, insects etc., Yes * Luminaries light transparency should be of Toughened glass Yes * Toughned transparent glass cover thickness >/=4 mm * Toughned Glass shall not get discoloured shall not suff

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.