Central Railway Tender

Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.

Central Railway - CR Tender

Goods
Electrical and Electronics
Electrical Works
Ireps
Opening Date3 Jan 2024
Closing Date29 Jan 2024
Tender Amount₹ 1,54,17,467.46 
Notes
Download

Costs

Summary

Various Signaling Works In Connection With:- (1) Replacement Of Old Age Indoor & Outdoor signalling Gears In New Relay Room & Power Room At Interlocked Lc Gates No.87 & 94 On Bsl division. (2)replacement Of Gf By Electrical Point Machine At Biswa Bridge & Deolali stations On Bsl Division. (3)rebuilding Of Various Small Span Bridges On Bsl-bd Section By rcc Box(17 Nos.)(469/4, 469/5, 470/3, 470/4, 470/5, 470/6, 552/1, 559/2, 582/4, 595/3, 595/3, 595/4, 455/3, 623/1, 651/2, 65/3, 655/5 & 651/3.) (4) Construction Of Rob Lc No.1b (s.c. Rly) Y, Mg Kms 568/11-12) And C.rly.bg Kms 567-62 (bsl-knw Bg Line In Knw yard) With Three Arm Near Teen Pulia Of Khandwa City. (5) Provision Of 3.66 M Wide Fob With 2.44 M Wide Ramp At Biswa Bridge Railway Station On Bsl Division.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Remote terminal unit with 64 digital and 16 analog inputs for IBH/Relay huts.SPN No.Spec No:IRS:S-99/2006(Amdt-3) (Inspection by RDSO) (Inspection by RDSO) 21A 0.20 Kilometre 292637.78 58527.56 (-) 8.25 53699.04 5

2

272717

500437.47

... More
Supply of PVC Flexible Copper Cable, Single core, multi strand 1x2.5 sq mm(50 conductor each 6 dia 0.25 + /- 0.01) as per specn IS 694/2010 with latest amendment. If any with insulation thickness of 0.70 mm nominal conductor resistance 7.98 ohms /km and test parameters are as per IRS (S)76/89 (Amdt .3). (Inspection by Consignee)

0.5

-

20449.08

... More
Supply of PVC Flexible Copper Cable, Single core, multi strand 1x10 sq mm(80 conductor each dia 7 0.40 + /- 0.01) as per specn IS 694/2010 with latest amendment. If any with insulation thickness of 1.00 mm nominal conductor resistance 1.91 ohms /km and test parameters are as per IRS (S)76/89 (Amdt .3). (Inspection by Consignee) 29A 8.00 Kilometre 6445.17 51561.36 (-) 8.25 47307.55 8 Descript ion:- Supply of wire 16/0.2(blue,red,gray,yellow,brown,black,white as per site engineer instruction)finolex/polycab/delton make.IRS:S-76/89(Amd.3),BS:4808 Part-2.Wire to be procured from RDSO approved vendor (Inspection by Consignee) 52A 80.00 Kg 129.53 10362.40 (-) 8.25 9507.50

0.8

-

103537.53

... More
Supply of Rubber Mat 5 mm thick for use in signalling installation. (Inspection by Consignee)

80

129

9507.5

... More
Supply of Auto changeover panel for 3 incoming supply single phase with manual bypass arrangement along with MCBs, switches, voltage sensing relays, fuses etc.of repute & approved make of suitable 10 rating.The panel should be made up of 16 SWG powder coated MS sheet. General arrangement & scheme to be in line with RDSO spec. and approved by Engineer incharge and as per RDSO Specn.No . TI/SPC/CLS/0023 with A & C Slip No. EN-13600 with the plated surface, or latest amendments.CAPACITY 63 Amps (Inspection by RDSO)

2

81872

150236.17

... More
Relay base plate complete with amophanols,code pins fixing screw etc.suitable for Metal to Metal 11 K-50 mini groups/ECRs of Siemens Make of functional equivalent of other makes. Note: Relay Base plates,are to be procured fom Relay manufacturer (OEM) Manufactures Certificate for procurement and guarantee in this regard should be furnished.The payment to be released only after Manufacturers Certificate is submitted. (Inspection by Consignee)

16

729

10714.2

... More
Supply of Time Element Relay (Clock work type) AG timer Siemens Make (No RSSK 30/0052). or GIC make or functional equivalent. (Inspection by Consignee)

4

7793

28602.59

... More
"Supply of Metal -To-Metal universal LED type ECR Siemens make (type A-RT-RG-A064) or functional equivalent without base plate, should be suitable for working with LED based signal lighting unit. IRS:S:46 & STS/E/RELAYS/AC LIT LED SIGNAL/09-2002 Amd. 1" (Inspection by RDSO)

16

6923

101631.25

... More
Supply of QNA1 AC immunized relay 8F-8B,24VDC along with plug board, retaining clip and connectors conforming to BRS:931A,IRS:S60,IRS:S34 & IRS:S23. (Inspection by RDSO)

50

3852

176726.56

... More
Supply of QNA1 -K AC immunized relay 12F-4B,24VDC along with plug board, retaining clip and connectors conforming to BRS:931A, & RDSO letter no STs/E/Relays/UEA/PI dated 30.05.97 Annexure-II IRS:S60,IRS:S34 & IRS:S23. (Inspection by RDSO)

30

4007

110295.98

... More
"Supply of Key Lock Relay working on 24V DC, AC immunized with different ward Combinations (Three ward plates to be supplied with each relay). RDSO /SPN / 219 / 2016 Version 1.0d1 (Inspection by Consignee) "

4

6527

23957.43

... More
"Supply of QNA1K relay 1000 ohm,6F/6B 24V DC as per BRS :931A, IRS:S60, IRS:S34 & IRS:S23 and RDSO spec. STS/ E/ Relays/UEA (PI) dtd.30.05.1997 Annexure II" (Inspection by RDSO)

4

4147

15222.94

... More
"Supply of Fail Safe Electronic Flasher Device 24V DC or 60V DC as per RDSO spec No.RDSO spec No.RDSO/SPN/173/2002 amendment 2 or latest." (Inspection by Consignee)

2

17965

32966.12

... More
"Supply of Indication cum operating panel as per RDSO spcn no: RDSO/SPN/186/2004 Rev. 2.0 with tag block completely wired with full complements like operating, emergency push buttons, with sealing 19 arrangement, pulse counters Non Resettable type, various buzzers(24V DC), SM's key and housed in a sheet metal cabinet similar to Siemens make in quality and finish. Each of the working domino should have all 15 terminals components. Different tone 3nos. buzzers and 6 non resettable counters are also wired as specified by Engineer incharge.The panel should have polycarbonated sheet cover on the top. SPARE:10% of working domino with cover plate completely wired and 10% of LEDs of each colour,10% (minimum three) of buttons, 10% of counter, 2 magnets, 1 buzzer & 4 bulb extractors shall be handed over as spare after commissioning of the installation by the contractor. Tag block shall conform to RDSO specn. IRS-S-77/2006.Manufaturer's name plate with address to be provided.[02 panel 0f 96 plates (12x8)]" (PLATE = NUMBER) (Inspection by Consignee)

192

508

89513.94

... More
"Panel Indication bulbs (Double LED type) working Voltage 24V -Colour- Red/Yellow/Green." (Inspection by Consignee)

100

44

4099.39

... More
"Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92" A) "With holder 1.6 A (System, Rapid or Mainad Make)." (Inspection by Consignee)

150

79

10998.99

... More
"Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92" B) With holder 0.6 A (System, Rapid or Malnad Make) (Inspection by Consignee)

32

77

2266.3

... More
"Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92" Without holder 1.6 A (System, Rapid or Malnad Make). (Inspection by Consignee)

150

23

3168.13

... More
"Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92" D) Without holder 0.6 A (System, Rapid or Malnad Make (Inspection by Consignee)

32

23

675.87

... More
"Supply of Resisters, condensers, Diodes, LEDs and lugs alongwith bracket and mounting arrangement as per standard Annexure-V of Central Railway." (Inspection by Consignee)

1

-

50956.56

... More
"Resin cored wire as per specification No. IS:1921-1975 with Alloying element percentage as 63% 26 SN (Tin) and / 37% Pb (Lead) with percentage of various impurities not exceeding the values Sb (Antimony) 0.2% maximum , Cu (Copper) 0.1% maximum, As (Arsenic) 0.05% maximum, Fe (Iron) 0.02% maximum & other impurities mainly Al, Zn & Cd shall be limited. The flux shall be free from corrosive action as per clause 5.2 & flux percentage may be used as per requirement." (Inspection by Consignee) 128A 10.00 Numbers 66.15 661.50 (-) 8.25 606.93

2

1252

2298.48

... More
Lacing thread rolls, black, wax coated (100 mtrs) (Inspection by Consignee)

10

66

606.93

... More
Design,fabrication and supply of fuse Auto changeover system for 32 Nos of external non 28 detorating Type fuses of G type fuses from 0.6 A Amp to 4A Amp capacities used in signalling circuits.System shall have 8 cards with monitoring arrangement of 4 fuses in one card.As per RDSO spec.RDSO/SPN/209/2012 Ver.2.0 or latest amendment if any. (NUMBER = NO. OF MODULES) (Inspection by RDSO)

6

26760

147315.07

... More
Supply of Main Signal Post 140 mm outer dia 5.6 Mtr Length as per spec No IRS S 6/81 with latest amendments. (Inspection by RITES)

2

9233

16943.29

... More
Supply of Cast Iron Main signal surface base140 mm as per spec No IRS S-10 and Drg No 2011/M 30 with latest amendments, with CLS ladder assembly complete for CLS signal 5.5/4.5/3.5 mtrs long as per R. No SA-23156(Adv),SA 23153(Adv) & SA 23150 (Adv) Alt. 1 respectively with latest Amendment as the case may be for CLS unit & signal back staging as per extant C.Rly practice. (Inspection by RITES) 139A 4.00 Numbers 521.69 2086.76 (-) 8.25 1914.60

2

9034

16577.61

... More
Supply of Signal No.plates. as per Drg No RST-11393/SK 842 (Inspection by Consignee)

4

521

1914.6

... More
Supply of A/AG/C/P/G/IB Board as per Drg RST-11444/1(A), RDSO Drg No SA 23460(AG), SA 23461( C) , RST-11445 , SA 23456(P), SA 23477(G) & SA 234476-77(IB) as applicable respectively with latest Amendment. (Inspection by Consignee) 145A 8.00 Numbers 286.20 2289.60 (-) 8.25 2100.71

4

561

2061.59

... More
Supply of Hand Cuff Locks with three common key (Inspection by Consignee)

8

286

2100.71

... More
Supply of 2 aspect signal unit in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev 2.0 or latest complete to suit LED signals lamps and suitable for 140 mm dia post saves pigment finish on the back side of the and inside . White pigment finish inside the 2 aspect unit to avoid any extra paint cost. (Inspection by RITES)

2

30939

56773.82

... More
Supply of 4 aspect signal unit in FRP body without lenses and transformers as per RDSO 35 Specification RDSO/SPN/194/2006/Rev 2.0 or latest complete to suit LED signals lamps and suitable for 140 mm dia post saves pigment finish on the back side of the and inside . White pigment finish inside the 4 aspect unit to avoid any extra paint cost. (Inspection by RITES)

2

41024

75280.07

... More
"Supply of Phenolic 10mm thick sheet, grade P3 in standard size of 1.22X1.22 Mtr as per spec. No IS 2036 of 1995." (Inspection by RITES)

8

5250

38538.52

... More
Supply of ARA Terminal blocks with links made of PBT Specn No.IRS/75/2006(Rev - 2) with latest amendments and RDSO Drg.No.SA-23741 Alt.4., SA-23745 Alt 5, SA-23746, SA-23748 Alt -4 & SA-23756 Alt-3. (Inspection by RDSO)

1500

72

99929.51

... More
Supply of cartridge fuse block made of PBT as per RDSO Drg No SA-23748 Alt 4,SA-23749 & Spec No IRS S 75/2006 with latest amendment. Fuse block shall be suitable for round head type voltage fuses. (Inspection by RDSO)

40

162

5979.9

... More
Supply of round head type non detoriating type low voltage cartridge fuse as per Specn No IRS/S/78/92 with latest amendments 2A/4A/6A capacity (Inspection by RDSO)

40

70

2573.77

... More
Supply of Tik-tak, piano type switches,5 A Make Anchor or CONA. (As per IS specification). (Inspection by Consignee)

4

33

122.61

... More
Supply of three pole plug and socket 5 Amp. Make Anchor or CONA(As per IS specification). (Inspection by Consignee) 163A 8.00 Numbers 22.73 181.84 (-) 8.25 166.84

4

230

847.26

... More
Supply of Lamp 110V/24W,2 Pin for Loc.(Inspection by Consignee)

8

22

166.84

... More
Supply of Apparatus Case with godown locks with deatachable handle on both the doors. A) Single Case as per Drg No SK 783-1&2. with latest alteration. (Inspection by RITES)

2

16020

29396.79

... More
Supply of Apparatus Case with godown locks with deatachable handle on both the doors. B) Half Case as per Drg No SK 783-1&2. with latest alteration. (Inspection by RITES) 165A 8.00 Numbers 1078.08 8624.64 (-) 8.25 7913.11

2

12853

23586.98

... More
Supply of earth electrode assembly as per Drg.No.CR/S&T/SK/815 (Inspection by Consignee)

8

1078

7913.11

... More
"Supply of Microprocessor based universal earth resistance sensing unit 12 channel AC/DC. as per RDSO/SPN/256/2002 with latest amendments." (Inspection by Consignee)

2

145626

267224.72

... More
Supply of 8 SWG GI wire (4mm dia) suitable for track circuit rail bonding .As per IRS specification S:13 - 62 (Inspection by Consignee)

40

86

3186.29

... More
Supply of Hydrometer, Exide make or similar for measuring specific gravity of Battery Graded acid with mounting stand in location Boxes.Consignee inspection under manufacturer certificate. (Inspection by Consignee)

6

283

1561.44

... More
Supply of Pre-wired Crank Handle cum key lock relay box(of metal) alongwith LEDs,with approved type push buttons,8-way terminal strips,string rod, etc as per Drawing No.RST.C.114 (Inspection by Consignee)

2

10467

19208.03

... More
Supply of GI pipe, inner dia. 100mm dia. B-class as per spec. No.IS 1239 PT.1/2004 or latest with sockets and fittings. TATA/JINDAL/ZENITH BIRLA Make. (Inspection by RITES) 212A 42.00 Metre 321.43 13500.06 (-) 8.25 12386.31 51

42

1029

39664.85

... More
"Supply of RCC pipe half round of size 150mm dia outer and 100 mm dia internal 1 mtr long matching to IS No.458/2003 amendment-1 with Rev.4." (Inspection by Consignee)

600

206

113480.07

... More
Supply of Modular Terminal block of 2.5 sqmm 2 IN 2 out type disconnect type terminal along with 53 a s per RDSO Specn.No.RDSO/SPN/189/2004 Rev 3.0. The current capacity of 16 Amps & more,The terminal should have marking at centre to view description from front.Material to be procured from RDSO approved firm only. (Inspection by Consignee) 220A 6.00 Numbers 216.73 1300.38 (-) 8.25 1193.10

600

117

64474.56

... More
Supply of End clamp for modular terminal block (Inspection by Consignee)

50

16

771.16

... More
"Tool bag complete with Megger as per Annexure -VIII. ADD AC /DC clamp meter , with Hand Held Tool Bag." (Inspection by Consignee)

1

-

47905.86

... More
"Supply of Electrically Operated LIFTING BARRIER complete set without Hand Generator, Operating on 110V AC, with Boom length 9.76M along with one spare boom confirming to RDSO/SPN/208/2012 Ver.2.0 with amendment 1 or latest amendment." (Inspection by RDSO)

2

307115

563557.33

... More
"Supply of Electronic Solid state flasher Unit for Road traffic signal 24V DC. ACES/ Muconny make with operating voltage 110V AC" (Inspection by Consignee)

2

1857

3408.88

... More
"Supply of Dual Tone Warning Bell with 20W horn and 15W Amplifier ACES/ Muconny make with operating voltage 110V AC." (Inspection by Consignee)

2

6496

11921.57

... More
"Supply of LED type boom light suitable for 110V AC color Red flashing body enclosure MS, CRC with mesh." (Inspection by Consignee)

2

863

1584.03

... More
"Supply of 4.5 kg CO2 type fire extinguisher along with all accesarios, extinguisher testing 62 certificate has to be supplied along with. - Supply of ISI marked Carbon diOxide type (BC) fire extinguisher of 4.5 Kg capacity confirming to IS 2878: 2004 from seamless cylinder, with IS marked control value, high pressure mtr., Long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting braket etc. as required by site Engineer." (Inspection by Consignee)

6

5019

27630.31

... More
Suppy,Installation,Testing & Commissioning of Microprocessor based intelligent,addressable,Fire Alarm Control Panel with LCD display compying to RDSO/SPN/217/2023 Ver 3 or latest Modular,1 loop (minimum 125 detector/devices per loop-expandable to 2 loops) with 320 charactor with soft keys for displaying alarm,events and operating functions,Day/Night operation function,Remote maintenance service feature etc.The 63 panel should be multi-Protocol i.e able to support at least 2 different makes of addressable detectors.The panel should have minimum two relayoutputs & 1 Monitored Sounder Output.It should have provision to be connected to repeater panel in future.The panel shall capable to operate on 230 volts AC power supply,automatic battery charger,24volts,sealed lead acid maintenance free batteries sufficient for 24 houres normal working and then be capable of operating the system for 30 minutes during emergency condition.Panel should be Vds certified. (Inspection by RDSO)

1

-

61672.8

... More
Suppy,Installation,Testing & Commissioning of Analogue Addressable Multisensor Detector complying to RDSO/SPN/217/2023 Ver 3 or latest As per latest VDS approved/listed.(Inspection by RDSO) 249A 1.00 Numbers 5226.59 5226.59 (-) 8.25 4795.40 65 Descrip tion: - Suppy,Installation,Testing & Commissioning of Manual call points,complying to RDSO/SPN/217/2023 Ver 3 or latest As per latest VDS approved/listed.(Inspection by RDSO) 250A 80.00 Metre 1414.13 113130.40 (-) 8.25 103797.14 66

9

3396

28050.64

... More
Supply,Installation,Testing & Commissioning of (LHS) Interface Module with all accessories for single stretch complying to RDSO/SPN/217/2023 Ver 3 or latest As per latest UL or FM or VDS or LPCB approved/listed.(Inspection by RDSO)

1

-

123113.95

... More
Supply,Installation,Testing & Commissioning of Analogue Addressable loop powered Monitor Module with inbuilt isolator complying to RDSO/SPN/217/2023 Ver 3 or latest (Inspection by RDSO)

1

-

8024.37

... More
Supply,Installation,Testing & Commissioning of Analogue Addressable loop powered Control Module complying to RDSO/SPN/217/2023 Ver 3 or latest (Inspection by RDSO)

1

-

8024.37

... More
Suppy,Testing & Commissioning of Hooter cum Strobe complying to RDSO/SPN/217/2023 Ver 3 or latest (Inspection by Consignee)

1

-

7109.1

... More
Suppy,Testing & Commissioning of 2C 1.5sq mm twisted shielded armoured copper cable (Per Meter) with accessories complying to RDSO/SPN/217/2023 Ver 3 or latest (Inspection by RITES)

120

113

12484.24

... More
Suppy,Testing & Commissioning of Isolator Device to isolate the circuit in case of short circuit, complying to RDSO/SPN/217/2023 Ver 3 or latest (Inspection by RDSO)

1

-

3414.38

... More
Suppy,Testing & Commissioning of Auto Telephone Dialler(GSM) to send the pre-recorded message to multiple mobile number, programmed earlier complying to RDSO/SPN/217/2023 Ver 3 or latest (Inspection by Consignee)

1

-

8535.95

... More
Supply of PVC Indoor Cable 1x60x0.6mm dia colour coding of insulation of inner core shall be in six colour Viz Blue , Red , Grey ,Green, Brown and Black conforming to IRS 76/89(Amdt 3) or latest. (Inspection by Consignee)

0.2

-

55174.01

... More
Supply of PVC Indoor Cable 1x 40x0.6mm dia. Colour coding of insulation of inner core shall be in eight colour viz Blue,Red,Grey,Green,Brown,Black, Yellow & white.conforming to IRS 76/89 (Amdt 3) or latest. (Inspection by Consignee)

0.2

-

36195.45

... More
Supply of PVC indoor cable 1 x 24 x 1 mm dia. Colour coding of insulation of inner Conductor shall be in eight colour viz Blue,Red,Grey,Green,Brown,Black, Yellow & white.conforming to IRS 76/89 (Amdt 3) or latest. (Inspection by Consignee)

0.5

-

134247.58

... More
Supply of low maintenance Lead Acid Secondary Cells 2V 80 AH. As per specn. IRS 88/2004 with latest amendment (Inspection by RDSO)

45

1997

82457.74

... More
Supply of Indoor Jumper Wire of various colour as per Railways standard practice of type ATC 1 x 0.6 mm dia.conforming to IRS 76/89 (Amdt 3) or latest. (Inspection by Consignee)

10

8647

79342.74

... More
Supply of Indoor Jumper Wire ATC 1 x 1 mm dia. conforming to IRS 76/89 (Amdt 3) or latest. (Inspection by Consignee)

1

-

12013.32

... More
Relay base plate complete with amophanols,code pins fixing screw etc.suitable for Metal to Metal K-50 mini groups/ECRs of Siemens Make of functional equivalent of other makes. Note: Relay Base plates,are to 7 be procured fom Relay manufacturer (OEM) Manufactures Certificate for procurement and guarantee in this regard should be furnished.The payment to be released only after Manufacturers Certificate is submitted. (Inspection by Consignee)

28

729

18749.85

... More
Major Relay Group Base Plates, complete with fedlisters (20 No per base plate), guide rails and 8 other accessories suitable for major group of Siemens make or functional equivalent of other makes. Note: Relay Base plates,are to be procured fom Relay manufacturer (OEM) Manufactures Certificate for procurement and guarantee in this regard should be furnished.The payment to be released only after Manufacturers Certificate is submitted. (Inspection by Consignee)

4

13439

49323.26

... More
Supply of Point Group PI, Siemens make (No RSSK 31/0001) or functional equivalent without base plates. (Inspection by RDSO)

4

87217

320086.76

... More
Supply of Key Lock Relay with different ward combinations (three extra set of ward plate for Point Machine to be supplied with each relay). Siemens Make working on 60V DC/24 DC or functional equivalent without base plates. RDSO/SPN/219/2016 Version 1.0 d 1. (Inspection by Consignee)

4

9145

33565.56

... More
"Supply of Plug In type Relay Metal to Metal type neutral relay mini groups (Non AC Immunised) 11 Siemens make (No. RSSK 30/0011) (Ref. IRS:S46/74 with Amd. 1 & firms specification.).or functional equivalent without base plates.Contact configuration 5F/3B or 6F/2B or 4F/4B to be specified by Engineer incharge." (Inspection by RDSO)

24

7143

157289.3

... More
"Supply of Plug In type Relay Interlocked Siemens make (No. RSSK 30/0012) or functional equivalant (Ref. IRS:S46/74 with Amd. 1 & firms specification.). Contact configuration 4F/4B." (Inspection by RDSO)

5

7548

34628.93

... More
Supply of QSPA1relay, 24VDC,Slow to pick up, 8F.4B along with plug board, retaining clip and connectors conforming to BRS:933A, IRS:S60, IRS:S34 & IRS:S23.(Inspection by RDSO)

10

4414

40506.98

... More
Supply of QTA2 AC immunised track relay, 9 Ohm,2F.1B, along with plug board,retaining clip and connectors conforming to BRS:939A, 966, & appendix F2, IRS:S34& IRS:S23 (Inspection by RDSO)

10

3859

35413.85

... More
"Supply of QNA1K relay 1000 ohm,6F/6B 24V DC as per BRS :931A, IRS:S60, IRS:S34 & IRS:S23 and RDSO spec. STS/ E/ Relays/UEA (PI) dtd.30.05.1997 Annexure II" (Inspection by RDSO)

12

4147

45668.82

... More
"Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92" A) "With holder 1.6 A (System, Rapid or Mainad Make)." (Inspection by Consignee)

32

79

2346.45

... More
"Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92" B) "With holder 6 A/10A ( D-Type Bharat Linder , L&T or HEVELLS Make)." (Inspection by Consignee)

4

270

993.07

... More
"Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92" C) Without holder 1.6 A (System, Rapid or Malnad Make). (Inspection by Consignee)

200

23

4224.17

... More
"Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92" D) Without holder 0.6 A (System, Rapid or Malnad Make) (Inspection by /consignee)

50

23

1056.04

... More
"Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92" E) "Without holder 6A/10A ( D- Type Bharat Linder , L&T or HEVELLS Make)." (Inspection by Consignee)

4

95

351.22

... More
"Resin cored wire as per specification No. IS:1921-1975 with Alloying element percentage as 63% 21 SN (Tin) and / 37% Pb (Lead) with percentage of various impurities not exceeding the values Sb (Antimony) 0.2% maximum , Cu (Copper) 0.1% maximum, As (Arsenic) 0.05% maximum, Fe (Iron) 0.02% maximum & other impurities mainly Al, Zn & Cd shall be limited. The flux shall be free from corrosive action as per clause 5.2 & flux percentage may be used as per requirement." (Inspection by Consignee) 128A 5.00 Numbers 66.15 330.75 (-) 8.25 303.46

2

1252

2298.48

... More
Supply of Phenolic 10mm thick sheet, grade P3 in standard size of 1.22X1.22 Mtr as per spec. No IS 2036 of 1995. (Inspection by RITES)

8

5250

38538.52

... More
Supply of ARA Terminal blocks with links made of PBT Specn No.IRS/75/2006(Rev - 2) with latest amendments and RDSO Drg.No.SA-23741 Alt.4., SA-23745 Alt 5, SA-23746, SA-23748 Alt -4 & SA-23756 Alt-3. (Inspection by RDSO)

1200

72

79943.61

... More
Supply of cartridge fuse block made of PBT as per RDSO Drg No SA-23748 Alt 4,SA-23749 & Spec No IRS S 75/2006 with latest amendment. Fuse block shall be suitable for round head type voltage fuses. (Inspection by RDSO)

16

162

2391.96

... More
Supply of round head type non detoriating type low voltage cartridge fuse as per Specn No IRS/S/78/92 with latest amendments 2A/4A/6A capacity (Inspection by RDSO)

16

70

1029.51

... More
Supply of Tik-tak, piano type switches,5 A Make Anchor or CONA (As per IS specification). (Inspection by Consignee) 163A 8.00 Numbers 22.73 181.84 (-) 8.25 166.84

8

33

245.23

... More
Supply of Lamp 110V/24W,2 Pin for Loc. (Inspection by Consignee)

8

22

166.84

... More
Supply of Apparatus Case with godown locks with deatachable handle on both the doors. A) Single Case as per Drg No SK 783-1&2. with latest alteration. (Inspection by RITES) 165A 8.00 Numbers 1078.08 8624.64 (-) 8.25 7913.11

8

16020

117587.17

... More
Supply of earth electrode assembly as per Drg.No.CR/S&T/SK/815 (Inspection by Consignee)

8

1078

7913.11

... More
Supply of Track Lead Juction Boxes as per C.Rly Drg. No.RST 11509 made from fiiber glass alongwith terminal blocks. (Inspection by Consignee)

30

1047

28845.65

... More
Supply of B type choke to specn.No.IRS.S.65/83 (Amdt -3) with latest amendments. (Inspection by RDSO)

9

3666

30274.89

... More
Supply of adjustable Track Feed Resistance disc type 7.5/15/30 ohms as per RDSO Drg. No. SA 20161-66/M (Adv) with latest amendments (with Phenolic moulded base). (Inspection by Consignee)

9

1288

10636.82

... More
Supply of Track feed battery chargers, 110V AC input 2, 4 to 6 V DC Output to Specn. No.IRS. 89/2013/Ver 1.0 with latest amendments. Charger shall be suitable for charging 80 AH battery. (Inspection by RDSO)

9

2430

20068.2

... More
Supply of Channel Pins single groove, galvanised, 7 mm suitable for 4mm dia bonding wire as per spec No IRS S 17-75 Revision 3. (Inspection by Consignee)

3000

2

5532.52

... More
Supply of PVC jacketed wire rope for Track Lead connections. PVC jacketed wire rope should be of 37 Galvanised steel wire rope 6 mm dia (6x19 stranded wire with steel core of 6 mm dia) sheathed with PVC 2mm wall thickness, overall thickness being 10 mm. PVC sheath should be made of type 6 compound as per IS 5831 of 1984 Reaffirmed 2001 and steel wire rope as per IS:2266:2019. Reclaimed or recycled material should not be used. (Inspection by Consignee)

200

52

9595.22

... More
Supply of 8 SWG GI wire (4mm dia) suitable for track circuit rail bonding .As per IRS specification S:13 - 62 (Inspection by Consignee)

20

86

1593.15

... More
Supply of Hydrometer, Exide make or similar for measuring specific gravity of Battery Graded acid 39 with mounting stand in location Boxes. Consignee inspection under manufacturer certificate. (Inspection by Consignee)

8

283

2081.92

... More
Supply, installation, testing and commissioning of track battery charger monitoring system for 2V/4V/6V/8V batteries with accessories at nominated stations.General Scheme to be approved by Engineer-in- charge (Inspection by Consignee)

9

1667

13765.34

... More
Supply, installation, testing and commissioning of remote indication unit along with all accessories for above item. (Inspection by Consignee)

2

843

1548.15

... More
Supply of Pre-wired Crank Handle cum key lock relay box(of metal) alongwith LEDs,with approved type push buttons,8-way terminal strips,string rod, etc as per Drawing No.RST.C.114 (Inspection by Consignee)

2

10467

19208.03

... More
Supply of William stretcher nylon insulation set suitable for ground connection as per RDSO drg No T-10367, T-10368, T-10384 as applicable and to the spec IRS S 23 & 40/84 with latest amendements. (Inspection by Consignee)

45

531

21959.58

... More
Supply of Tongue attachment nylon insulation set consisting of one insulating plate as per Drg no: RST-106961 & 3 nos of Ferrules with collars to suite rodding supplied as per RDSO spec & Drg.no: RST-10692. (Inspection by Consignee)

27

338

8380.54

... More
Supply Gauge Tie plate nylon insulation as per RDSO drg No: T- 10372Alt2, T-10368, T- 10371Alt2, T-15083/88/Alt2 & T-11690/Alt2 and to the spec IRS S 23 & 40 with latest amendements 01 or latest amandments . (Inspection by Consignee)

27

244

6047.21

... More
Supply of Ground connections, complete set suitable for IRS type/appd. point Machine for ordinary 46 turnout with tounge attachment insulation and other insulation as per RDSO Drg. S/3361 /62 /63 for IRS type point machine) or RDSO Drg No.SA-9151/52 (for Siemens point machine) with latest amendements . However the ground connection shall be procured only after confirmation from Railway engineer as per site condition /type of machine/turnout. (Inspection by RITES)

8

8171

59977.49

... More
Supply of GI pipe, inner dia. 100mm dia. B-class as per spec. No.IS 1239 PT.1/2004 or latest with sockets and fittings. TATA/JINDAL/ZENITH BIRLA Make. (Inspection by RITES)

120

1029

113328.13

... More
Supply of DWC HDPE Pipe with one snap fit coupler and 'O' ring fire resistant, anti rodent,in 6mtr length of size 120 mm outer dia as per RDSO /SPN /204 /2011 /Ver 1.1 with Amdt 1 or latest. (Inspection by RITES)

240

321

70778.89

... More
"Supply of RCC pipe half round of size 150mm dia outer and 100 mm dia internal 1 mtr long matching to IS No.458/2003 amendment-1 with Rev.4." (Inspection by Consignee)

2000

206

378266.9

... More
Supply of RCC pipe half round of size 300mm dia outer and 250 mm dia internal 1 mtr long. matching to IS No.458/2003 amendment-1 with Rev.4. (Inspection by Consignee)

300

422

116224.31

... More
Supply of Modular Terminal block of 2.5 sqmm 2 IN 2 out type disconnect type terminal along with 51 a s per RDSO Specn.No.RDSO/SPN/189/2004 Rev 3.0. The current capacity of 16 Amps & more,The terminal should have marking at centre to view description from front.Material to be procured from RDSO approved firm only. (Inspection by Consignee) 220A 7.00 Numbers 216.73 1517.11 (-) 8.25 1391.95

800

117

85966.08

... More
Supply of marker card as per customer spec(10x10) (Inspection by Consignee)

8

83

615.17

... More
"Tool bag complete with Megger as per Annexure -VIII. ADD AC /DC clamp meter , with Hand Held Tool Bag." (Inspection by Consignee)

2

52213

95811.72

... More
Supply of thermo shrink Jointing kit (Reinforced) TSF-2 type generally conforming to RDSO 57 Specification No.RDSO/SPN/TC/57/2015 Rev 1 with modified kit contents as per CSTE Specification No.CR/SPN/TC/57 (A)/2015 dtd 06.01.2015(Table -A) to be suitable for jointing both 10/20/50 pair PIJF and 4/6 Quad cables alongwith sub-kit(Table-B) for armour continuity. (Inspection by RDSO)

8

2991

21961.06

... More
Supply of Phenolic 10mm thick sheet, grade P3 in standard size of 1.22X1.22 Mtr as per spec. No IS 2036 of 1995. (Inspection by RITES)

20

5250

105009.6

... More
Supply of ARA Terminal blocks with links made of PBT Specn No.IRS/75/2006(Rev - 2) with latest amendments and RDSO Drg.No.SA-23741 Alt.4., SA-23745 Alt 5, SA-23746, SA-23748 Alt -4 & SA-23756 Alt-3. (Inspection by RDSO)

2230

72

161920.3

... More
Supply of earth electrode assembly as per Drg.No.CR/ S&T /SK/815 (Inspection by Consignee)

22

1078

23717.76

... More
Supply of Apparatus Case with godown locks with deatachable handle on both the doors. A) FULL CASE (Inspection by RITES)

16

16020

256320.8

... More
Supply of Apparatus Case with godown locks with deatachable handle on both the doors. B) HALF CASE (Inspection by RITES)

6

12853

77123.64

... More
Supply of GI pipe, inner dia. 100mm dia. B-class as per spec. No.IS 1239 PT.1/2004 or latest with sockets and fittings. TATA/JINDAL/ZENITH BIRLA Make. (Inspection by RITES)

384

1029

395258.88

... More
Supply of DWC HDPE Pipe with one snap fit coupler and 'O' ring fire resistant, anti rodent,in 6mtr length of size 120 mm outer dia as per RDSO / SPN / 204 / 2011 / Ver 1.1 with Amdt 1 or latest. (Inspection by RITES)

320

321

102857.6

... More
Supply of thermo shrink Jointing kit (Reinforced) TSF-2 type generally conforming to RDSO 8 Specification No.RDSO/SPN/TC/57/2015 Rev 1 with modified kit contents as per CSTE Specification No.CR/SPN/TC/57 (A)/2015 dtd 06.01.2015(Table -A) to be suitable for jointing both 10/20/50 pair PIJF and 4/6 Quad cables alongwith sub-kit(Table-B) for armour continuity. (Inspection by RDSO)

48

2991

143614.56

... More
Supply of Indoor Jumper Wire of various colour as per Railways standard practice of type ATC 1 x 0.6 mm dia.conforming to IRS 76/89 (Amdt 3) or latest. (Inspection by Consignee)

5

8647

43238.55

... More
Supply of PVC Flexible Copper Cable, Single core, multi strand 1x2.5 sq mm(50 conductor each 3 dia 0.25 + /- 0.01) as per specn IRS 694/2010 with latest amendment. If any with insulation thickness of 0.70 mm nominal conductor resistance 7.98 ohms /km and test parameters are as per (S)76/89 (Amdt .3). (Inspection by Consignee)

1

44575

44575.65

... More
Supply of Auto changeover panel for 3 incoming supply single phase with manual bypass 4 arrangement along with MCBs, switches, voltage sensing relays, fuses etc.of repute & approved make of suitable rating.The panel should be made up of 16 SWG powder coated MS sheet. General arrangement & scheme to be in line with RDSO spec. and approved by Engineer incharge and as per RDSO Specn.No . TI/SPC/CLS/0023 with A & C Slip No. EN-13600 with the plated surface, or latest amendments.CAPACITY 63 Amps. (Inspection by RDSO)

1

81827

81827.54

... More
Supply of QNA1K relay 1000 ohm,6F/6B 24V DC as per BRS :931A, IRS:S60, IRS:S354 & IRS:S23 and RDSO spec. STS/ E/ Relays/UEA (PI) dtd.30.05.1997 Annexure II (Inspection by RDSO)

15

4147

62219.1

... More
Supply of QNA1 AC immunized relay 8F-8B,24VDC along with plug board, retaining clip and connectors conforming to BRS:931A, IRS:S60, IRS:S34 & IRS:S23. (Inspection by RDSO)

15

3852

57785.25

... More
"Supply of Phenolic 10mm thick sheet, grade P3 in standard size of 1.22X1.22 Mtr as per spec. No IS 2036 of 1995." (Inspection by RITES)

6

5250

31502.88

... More
Supply of ARA Terminal blocks with links made of PBT Specn No.IRS/75/2006(Rev - 2) with latest amendments and RDSO Drg.No.SA-23741 Alt.4., SA-23745 Alt 5, SA-23746, SA-23748 Alt -4 & SA-23756 Alt-3. (Inspection by RDSO)

3000

72

217830

... More
Supply of cartridge fuse block made of PBT as per RDSO Drg No SA-23748 Alt 4,SA-23749 & Spec No IRS S 75/2006 with latest amendment. Fuse block shall be suitable for round head type voltage fuses. (Inspection by RDSO)

100

162

16294

... More
Supply of Apparatus Case with godown locks with deatachable handle on both the doors. A) Single Case as per Drg No SK 783-1/2. with latest alteration. (Inspection by RITES)

6

16020

96120.3

... More
Supply of earth electrode assembly as per Drg.No.CR/S&T/SK/815 (Inspection by Consignee)

6

1078

6468.48

... More
"Supply of Microprocessor based universal earth resistance sensing unit 12 channel AC/DC. as per RDSO/SPN/256/2002 with latest amendments." (Inspection by Consignee)

1

145626

145626.55

... More
"Supply of Single Section Digital Axle Counter (SSDAC) with two detection point with reset arrangement and vital relay box as per RDSO /SPN /177 /2012 Ver.03 or Latest. Each set consist of following:- a)High frequency TX coil and RX coil (Each set consist of web mounting type TX coils-2 Nos. RX coils-2 Nos along with 10 mtr cable-2 sets) , b)Track side digital axle counter unit-2 nos c) 24V 6F/4B, 1000 ohm ""Q"" type relay Box duly wired -2Nos. d)Clamp with deflector plates and hardware etc-4nos , e)Reset Box 2Nos ii)Mushroom/Location Box suitable for housing Track side equipment (2 Nos) 2) Transportation, Installation testing & commissioning:- Transportation, Installation testing & commissioning of equipment field training (one man day per set) at site or as desired by site Engineer. These includes: - a) Foundation & erection of Track side 16 Equipment i.e. Mushroom/ Location Box (If required). This includes supply of all associated materials., -b) No. Individual Earthing of all detection Point for the OEM recommended earth value certified by OEM site engineer. This includes supply & installation of maintenance free earth materials and exothermic bonding and other connecting cable etc as per Railway practice (As per RDSO Spec. no: RDSO /SPN /197 /2008 or latest. Resetting equipment to be connected to the EI Ring earth. c) Installation to be carried out by OEM certified Engineer. 3) Tool Kit consisting of:- a) Digital True RMS multi meter of suitable make for above Digital Axle counter system with probe set- Ino b) Train Simulator(High frequency)-1 no c) Extender Card-ino d) Dummy wheel-ino e) Different type of spanners suitable for above Digital Axle counter- 1set f) Torque wrenches suitable for the above-1 no g) Screw driver set suitable for the above- 1Set h) Carrying Bag for Tools-1No. i) 6 nos. Electrostatic Discharge Wrist Band for cards/ modules protection." (Inspection by RDSO)

2

440628

881257.96

... More
Supply of GI pipe, inner dia. 100mm dia. B-class as per spec. No.IS 1239 PT.1/2004 or latest with sockets and fittings. TATA/JINDAL/ZENITH BIRLA Make. (Inspection by RITES)

180

1029

185277.6

... More
Supply of DWC HDPE Pipe with one snap fit coupler and 'O' ring fire resistant, anti rodent,in 6mtr length of size 120 mm outer dia as per RDSO / SPN / 204 /2011 /Ver 1.1 with Amdt 1 or latest. (Inspection by RITES)

210

321

67500.3

... More
Supply of Phenolic 10mm thick sheet, grade P3 in standard size of 1.22X1.22 Mtr as per spec. No IS 2036 of 1995. (Inspection by RITES)

4

5250

24782.27

... More
Supply of ARA Terminal blocks with links made of PBT Specn No.IRS/75/2006(Rev - 2) with latest amendments and RDSO Drg.No.SA-23741 Alt.4., SA-23745 Alt 5, SA-23746, SA-23748 Alt -4 & SA-23756 Alt-3. (Inspection by RDSO)

500

72

42839.9

... More
"Supply of cartridge fuse block made of PBT as per RDSO Drg No SA-23748 Alt 4,SA-23749 & Spec No IRS S 75/2006 with latest amendment. Fuse block shall be suitable for round head type voltage fuses." (Inspection by RDSO)

10

162

1922.69

... More
Supply of round head type non detoriating type low voltage cartridge fuse as per Specn No IRS/S/78/92 with latest amendments 2A/4A/6A capacity (Inspection by RDSO)

10

70

827.53

... More
Supply of Tik-tak, piano type switches,5 A Make Anchor or CONA (As per IS specification). (Inspection by Consignee)

4

33

157.7

... More
Supply of Apparatus Case with godown locks with deatachable handle on both the doors. A) Single Case as per Drg No SK 783-1&2. with latest alteration. (Inspection by RITES) 165A 4.00 Numbers 1078.08 4312.32 18.00 5088.54

4

16020

75614.64

... More
Supply of earth electrode assembly as per Drg.No.CR/S&T/SK/815 (Inspection by Consignee)

4

1078

5088.54

... More
"Supply of GI pipe, inner dia. 100mm dia. B-class as per spec. No.IS 1239 PT.1/2004 or latest with sockets and fittings. TATA/JINDAL/ZENITH BIRLA Make." (Inspection by RITES)

12

1029

14575.17

... More
Supply of DWC HDPE Pipe with one snap fit coupler and 'O' ring fire resistant, anti rodent,in 6mtr length of size 120 mm outer dia as per RDSO /SPN /204/2011/Ver 1.1 with Amdt 1 or latest. (Inspection by RITES)

60

321

22757.24

... More
Supply of RCC pipe half round of size 300mm dia outer and 250 mm dia internal 1 mtr long. matching to IS No.458/2003 amendment-1 with Rev.4. (Inspection by Consignee) 220A 8.00 Numbers 216.73 1733.84 18.00 2045.93

200

422

99651

... More
Supply of marker card as per customer spec(10x10) (Inspection by Consignee)

30

83

2966.87

... More
Supply of thermo shrink Jointing kit (Reinforced) TSF-2 type generally conforming to RDSO 15 Specification No.RDSO/SPN/TC/57/2015 Rev 1 with modified kit contents as per CSTE Specification No.CR/SPN/TC/57 (A)/2015 dtd 06.01.2015(Table -A) to be suitable for jointing both 10/20/50 pair PIJF and 4/6 Quad cables alongwith sub-kit(Table-B) for armour continuity. (Inspection by RDSO)

4

2991

14122.1

... More
Installation of relay rack assembly including IDF pillars if any complete with wall support, scaffolding, ladders, runway for cables,Relay/Relay group base plates, fixing of Tag block etc.The work shall be done as per approved plan, extant practice on C. Railway & instruction of Rly. Engineer at site.

4

1534

5632.46

... More
Installation of Cable Termination Racks Assembly complete including wall supports, scaffolding, Disconnecting links/ARA terminal, 96 way tag block with tagblock cover & other necessary accessories etc. The work shall be done as per approved plan, extant practice on C. Railways & the instruction of Rly engineer at site.

2

1306

2397.67

... More
Installation, wiring, testing and commissioning of Remote Terminal Unit complete along with 3 accessories with Contractors own wiring & fixing material. (It includes loading of NETWORKING software and networking with data logger. The requisite communication cable/channel for networking will be arranged by Railway.

2

9906

18178.34

... More
"Fixing of Q series relay base plate/metal to metal relay mini group and major group base plate, laying, bunching, lacing, dressing & packeting of 60/40 core PVC indoor cable/flexible wire and termination of 4 60/40 core cable/flexible wire on tagblock/base plate & base plates & soldering. This includes fuse wiring, bus bar looping etc. required for keeping installation ready for circuit wiring work & panel throughing work. The work shall be done as per approved plan, extant practice on C.Rly. & the instruction of Rly. Engineer at site." (PER TAG BLOCK = PER NUMBER)

6

626

3446.63

... More
Circuit wiring/jumpering as per circuit diagrams in the relay racks/IDF rack tagblocks. This includes preparation of Jumper sheets by wire man duly checked by firm's site supervisor & wire to wire testing as per 5 circuit diagram. Any wrong jumper done by wireman will not be paid & correction shall be done free of cost. Jumper wires will be issued by Railways. Good quality solder rosin core to be supplied by contractor for soldering of Jumper wires. Soldering of jumper wires to be done after completion of testing by Railways.( JUMPER = NUMBER)

2000

12

22331.95

... More
Wiring and charging of Integrated Power Supply to signalling installation.. This includes connection of MF earth of 1 ohm earth resistance , for IPS and power distribution connection to bus bars and relay racks in 6 the room with contractor's own wiring materials and fabrication and fixing of AC/DC power distribution board made on 10mm thick Phenolic hylam sheets or any standard make with connections suitable for 63 A.Wiring to be done considering site requirement , depending upon the load with suitable wires,lugs & glands as per instructions of Engineer-in-charge. This item also includes supply & fixing of ladder along the wall for carrying power supply wires/cables from IPS room to Relay room/power room and potential free contact wiring at Datalogger IDFetc.

2

31176

57209.39

... More
Wiring,Fixing & commissionig of modules of fuse 0.6 to 4 Amp rating alarm system having change over arrangement and potential free contact witing at Datalogger IDF Etc as per instruction of Railway Engineer (Module of 32 nos fuses) (NO OF MODULES = NUMBER)

6

646

3561.02

... More
"Lettering & Numbering of detail and description writing of particulars of terminations & equipments 8 on relay rack, relays, cable termination rack, battery & power equipments, IPS, operating panel, axle counter etc constituting entire system with contractor's own paint and writing material (""Asian/Dulux"" make enamel paints to be used). The work shall be done as per extant practice on C.Rly & instruction of Rly engineer at site."

6

368

2028.43

... More
"Design and supply of Detailed Signalling Circuits including Panel diagram(if required) , Route section Plan , Selection Table , Fuse & Negative Tag. Analysis , Contact analysis , Relay Rack Arrangement and wire count sheets etc. in A3 size.Completion circuit shall be plotted in AutoCAD. The contractor shall initially supply 2 sets of circuits duly signed by the circuit designer having substantial experience on design side for 9 making such circuits, complete for approval of Railways. Railways will return one set of circuit to the contractor duly approved with alterations /corrections, if any. The contractor shall incorporate Railway's alterations/corrections in the original tracings & CD without any deviation and submit two copies of the modified circuits. Original tracings so modified & final CD complete in all respects alongwith 6 sets of final approved circuits (out of which one set shall be supplied in transparent bags. Only two sheets of circuits shall be placed in one bag each) shall be submitted to the Railways in case there are no further alteration suggested by Railways. This also includes modifcation in yard." A) "for IBS/ABS/LC Gate"

2

48176

88404.15

... More
Excavation and Casting of main signal foundation as per Drg No SK 801 with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost.

4

9149

33578.08

... More
Erection of CLS Post with Surface base and signal unit on top or on OFF set Bracket, fixing of front 11 and back staging, ladder and guards, signal name plates/boards if any with contractors own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any. The work shall be done as per instructions of Rly engineer at site.

4

3490

12809.11

... More
"Termination of tail cable on Main signal units and wiring with contractor own material, etc. The work shall be done as per instruction of Rly engineer at site."

4

1096

4023.31

... More
Fabrication and fixing of phenolic laminated/Fibre glass sheet in location box by providing all 13 fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe covered string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783-1/2. with latest alterations & as per instructions of Rly engineer at site. A) Single Case

2

2251

4131.92

... More
Fabrication and fixing of phenolic laminated/Fibre glass sheet in location box by providing all 14 fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe covered string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783-1/2. with latest alterations & as per instructions of Rly engineer at site. B) Half Case Per 44B 1500.00 14.05 21075.00 (-) 8.25 19336.31

2

1984

3642.07

... More
Excavation and Casting of Apparatus Case foundation with contractors Anchor bolts, cement, ballast and other materials.The required Scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost A) Single Case as per Drg No SK 803

2

9887

18142.68

... More
Excavation and Casting of Apparatus Case foundation with contractors Anchor bolts, cement, ballast and other materials.The required Scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost B) Half Case as per Drg No SK 804

2

9693

17788.36

... More
Erection of Apparatus Cases. This includes filling of location foundations and plastering A) Single Case

2

1098

2014.9

... More
Erection of Apparatus Cases. This includes filling of location foundations and plastering B) Half Case

2

842

1545.8

... More
Installation of Eqpt. (Relays, resistance, chargers batteries etc.as applicable) & wiring of the same in apparatus Cases as per location diagrams & circuit diagrams, as per Instruction of site incharge and practice. A) Single Case

2

1497

2748.32

... More
Installation of Eqpt. (Relays, resistance, chargers batteries etc.as applicable) & wiring of the same in apparatus Cases as per location diagrams & circuit diagrams, as per Instruction of site incharge and practice. B) Half Case

2

1017

1867.63

... More
Installation of earth electrode assenbly as per Drg.No.RE/S&T/SIG/Tender/SK726/85 including earth wire connected through GI wire 8 SWG supported on M.S. flat of size 6mm x 40 mm to earth electrode as 22 per drg. No.CR/S&T/SK-815 for sigg. Equipment such as lever frames, apparatus case, signals, relay racks,block insruments, and etc. as per RE manual. The earth value should be less than 10 Ohms including the lead wire. The value should be measured in presence of Rly. supervisor. It should be documented and painted on earth enclosure made of concrete.( only earth electrode will be supplied by Railway). All other material required for provision of earthing will be brought by the contractor.

8

2528

18556.55

... More
Installation, wiring,testinng & commissioning of Microprocessor based universal earth leakage detector unit 12 channel AC/DC

2

7411

13599.24

... More
Excavation of cable trench as per cable route plan,1.0 mt. deep and 300mm wide along side the track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm thickness after clearing of 24 route,bushes etc.It shall be ensured that top of the cables laid is at a depth of 0.8 m or more If it is less,then the width and depth shall be suitably increased and accordingly proportionate payment shall be made .In case depth of trench is not achievable due to site conditions,Proportionate payment will be made as per procedure.The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site.Drg No.SK 805

300

350

96337.5

... More
Excavation of cable trench as per cable route plan,1.0 mt. deep and 300mm wide along side the track in hard soil, conforming to distances as per cable route plan and refilling after cable laying. This work 25 includes covering of cable laid in trench by loose soil for a layer of 50mm thickness after clearing of route,bushes etc.It shall be ensured that top of the cables laid is at a depth of 0.8 m or more If it is less,then the width and depth shall be suitably increased and accordingly proportionate payment shall be made .In case depth of trench is not achievable due to site conditions,Proportionate payment will be made as per procedure.The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site.Drg No.SK 805

60

583

32112.32

... More
Cutting of all types of Roads/ platforms (except concrete type ) for trenching and excavation to depth of 300mmx300mm wide approx. and refilling after laying of RCC/GI/DWC pipe & to restore them to original condition. The work shall be done as per extant practice on C.Rly & instructions of Rly engineer at site.SK-807

8

2916

21408.36

... More
Digging of trench 1.0M deep from rail flange/road level (for LC) and 0.3 mtrs to 0.6 Mtrs wide and 27 back filling after placing of DWC/RCC/GI pipe (Placing of DWC/RCC/GI pipe coverd separately) The ballast disturbed be screened and dressed as required by Engineerin-charge or his representatives and road tarred immediately.Drg No.SK 806 87B 2.00 Kilometre 5197.42 10394.84 (-) 8.25 9537.27

12

583

6422.46

... More
Laying of signalling/Power/Telecom cable of various cores/sizes in trenches.

2

5197

9537.27

... More
Provision of brick masonary duct as per Rly.Drg.No. PA/N/CN/STD/19(modified) after cutting of platform/excavating the earth for the duct with contractor's own materials and restoring the excavated earth to its original condition.

30

2034

56009.25

... More
Whereever depth of 0.5 m cable trench is not feasible cable shall be protected as under :- Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench.

5

5329

24449.31

... More
"Fixing of modular terminal/fuse blocks alongwith all accessories with provision of fixing holes on 31 hylam sheets/side angles of Loc Box and fixing by galvanised nuts & bolts. This includes fixing of DIN channel alongwith PVC Comb type 'C' channel (size 2 inch x 2 inch) for cable termination on modular terminal. The PVC channel with cover to be supplied by firm as required. The work shall be done as per the instruction"

600

19

10487.02

... More
Termination of cable cores on ARA terminal/Disconnecting link/fuse blocks, in the apparatus Cases/ cable termination rack. This includes all associated works of pulling out the cable from underground. The work shall be done as per location plans and instructions of Rly engineer at site.

2140

7

13940.5

... More
Laying of GI pipes in on bridges/culverts/concrete drain/ mountain ridges etc. with suitable GI bend 33 shall be provided where there is turning of pipe as per instructions of the site engineer. GI Clamps at every 2 m as shown in the drawing to be fixed. Suitable holes to be made in the pipe before laying as per instructions of the site engineer. 100 mm dia. Drg No SK 808

42

143

5531.31

... More
Horizontal boring of cable duct of minimum 2.0 mtr depth along with laying of 120 mm HDPE pipe for track crossing wirh minimum depth reckoned from bottom of the rail/Road crossing with minimum depth 34 reckoned from ground level. The work shall be done as per extent practice & instruction of site engineer.Preparation of site for Horizontal boring shall be carried out in presence of Railway Representative.HDPE will be supplied by Railway. Note:- Contractor shall provide all material required for boring and adequate nos.of labours for proper laying of cable into the bore.Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable.

64

2610

153286.21

... More
Laying of RCC half round cement pipe of approximate size (150/300 mm dia X 2 Meter length) 35 inside the trench after laying of cable. Pipes shall be placed as per directives of engineer

600

36

20065.72

... More
"Installation ,testing and commissioning of electrically operated lifting barrier, complete with Casting 36 of cement concrete foundation for pedestal and boom rest post, cabling power supply connection & wiring with complete outdoor work. All the materials, tools required for commissioning of LC Gate will be arranged by the contractor. (As per Central Railway standard practice)."

2

12167

22326.59

... More
Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of paints.Wherever required 37 contractor shall apply coating of epoxy paint also as per instructions of site-in-charge.Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. A)"Apparatus Case Full Size."

2

435

799.03

... More
Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of paints.Wherever required 38 contractor shall apply coating of epoxy paint also as per instructions of site-in-charge.Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. B) "Apparatus case Half Size."

2

326

600.03

... More
Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of paints.Wherever required 39 contractor shall apply coating of epoxy paint also as per instructions of site-in-charge.Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. C) "Main Signal Post with Signal Units, Surface base and complete fittings as per Central Railways standard practice."

4

756

2778.01

... More
Lettering / Numbering of Signals, Point Machine, Track Lead Junction Boxes, Block Joints, Apparatus Cases etc. (each item to be taken as One Unit) This work will be carried out as per the standard practice being followed in Central Railway.

8

56

415.74

... More
Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes. A) FULL CASE

2

263

483.58

... More
Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes. B) HALF CASE

2

150

275.31

... More
Installation Testing and Commsiong of Fire etection,Aspiration including flame sesor, LHS Cable flame sensor aspiration type smoke sensor as per RDSO SPN No. RDSO/SPN/217/2018 Version No.: 2.0. This 43 includes Control module for the Control Unit, Monitor Module for the Control Unit.LHS Interface should be a microprocessor based start point device that communicates between LHS Cable and Control Unit should be an intelligent device that will monitor LHS cable for continuity and over temperature fire signatures. This also includes Supply, Installation, Testing and Commissioning of Integrated Remote Monitoring System Software for complete as per specifications, for integrating , Fire Alarm System, VESDA System for monitoring at Division head quarter.

1

-

28043.23

... More
Charging of 2V Lead Acid Batteries with contractors own battery grade sulphuric acid and distilled 1 water with minimum two charge - discharge cycles, installation of charged batteries in groups & their connection & wiring. The work shall be done as per extant practice of C.Rly & instruction of Engineer-in-charge.Detailed measurements of initial charging shall be recorded jointly by contractor & Rly's site-in-charge. (PER 100 VAh = NUMBER)

45

75

3132.48

... More
"Fixing of Q series relay base plate/metal to metal relay mini group and major group base plate, 2 laying, bunching, lacing, dressing & packeting of 60/40 core PVC indoor cable/flexible wire and termination of 60/40 core cable/flexible wire on tagblock/base plate & base plates & soldering. This includes fuse wiring, bus bar looping etc. required for keeping installation ready for circuit wiring work & panel throughing work. The work shall be done as per approved plan, extant practice on C.Rly. & the instruction of Rly. Engineer at site." (PER TAG BLOCK = NUMBER)

6

626

3446.63

... More
"Circuit wiring/jumpering as per circuit diagrams in the relay racks/IDF rack tagblocks. This includes preparation of Jumper sheets by wire man duly checked by firm's site supervisor & wire to wire testing as per 3 circuit diagram. Any wrong jumper done by wireman will not be paid & correction shall be done free of cost. Jumper wires will be issued by Railways. Good quality solder rosin core to be supplied by contractor for soldering of Jumper wires. Soldering of jumper wires to be done after completion of testing by Railways." (JUMPER = NUMBER)

1000

12

11165.98

... More
Wiring,Fixing & commissionig of modules of fuse 0.6 to 4 Amp rating alarm system having change over arrangement and potential free contact witing at Datalogger IDF Etc as per instruction of Railway Engineer (Module of 32 nos fuses) (NO OF MODULES = NUMBER)

2

646

1187.01

... More
"Lettering & Numbering of detail and description writing of particulars of terminations & equipments 5 on relay rack, relays, cable termination rack, battery & power equipments, IPS, operating panel, axle counter etc constituting entire system with contractor's own paint and writing material (""Asian/Dulux"" make enamel paints to be used). The work shall be done as per extant practice on C.Rly & instruction of Rly engineer at site."

4

368

1352.28

... More
Fabrication and fixing of phenolic laminated/Fibre glass sheet in location box by providing all 6 fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe covered string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783-1/2. with latest alterations & as per instructions of Rly engineer at site. A) SINGLE CASE

8

2251

16527.7

... More
Fabrication and fixing of phenolic laminated/Fibre glass sheet in location box by providing all 7 fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe covered string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783-1/2. with latest alterations & as per instructions of Rly engineer at site. B) HALF CASE Per 44B 1216.00 14.05 17084.80 (-) 8.25 15675.30

4

1984

7284.14

... More
Excavation and Casting of Apparatus Case foundation with contractors Anchor bolts, cement, ballast and other materials.The required Scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost A) Single Case as per Drg No SK 803

8

9887

72570.73

... More
Excavation and Casting of Apparatus Case foundation with contractors Anchor bolts, cement, ballast and other materials.The required Scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost B) Half Case as per Drg No SK 804

4

9693

35576.72

... More
Erection of Apparatus Cases. This includes filling of location foundations and plastering A) SINGLE CASE

8

1098

8059.61

... More
Erection of Apparatus Cases. This includes filling of location foundations and plastering B) HALF CASE

4

842

3091.61

... More
Installation of Eqpt. (Relays, resistance, chargers batteries etc.as applicable) & wiring of the same in apparatus Cases as per location diagrams & circuit diagrams, as per Instruction of site incharge and practice. A) SINGLE CASE

8

1497

10993.26

... More
Installation of Eqpt. (Relays, resistance, chargers batteries etc.as applicable) & wiring of the same in apparatus Cases as per location diagrams & circuit diagrams, as per Instruction of site incharge and practice. B) HALF CASE

4

1017

3735.25

... More
Installation of earth electrode assenbly as per Drg.No.RE/S&T/SIG/Tender/SK726/85 including earth wire connected through GI wire 8 SWG supported on M.S. flat of size 6mm x 40 mm to earth electrode as 15 per drg. No.CR/S&T/SK-815 for sigg. Equipment such as lever frames, apparatus case, signals, relay racks,block insruments, and etc. as per RE manual. The earth value should be less than 10 Ohms including the lead wire. The value should be measured in presence of Rly. supervisor. It should be documented and painted on earth enclosure made of concrete.( only earth electrode will be supplied by Railway). All other material required for provision of earthing will be brought by the contractor.

8

2528

18556.55

... More
Erection, Fitting and Rail connection of Track Lead Juntion Box on two supports(M.S.angle) with 16 contractor's fixing material and PVC jacketed wire for track lead connection including angles of size 40 x 40 x 5 mm 1200 mm length. This will include drilling of holes for track lead/side connections on rail. The work shall be done as per Drg. No.SK-845 or/ & instructions of Rly engineer at site.

30

1305

35929.48

... More
Provision of bonding with contractor's PVC jacketed wire rope for Track Lead connections.PVC jacketed wire rope should be of Galvanised steel wire rope 6mm dia (6 x 19 stranded wire with steel core of 6 mm 17 dia ) sheathed with PVC 2mm wall thickness, overall thickness being 10mm PVC sheath should be made of type 6 compound as per IS 5831 of 1984 Reaffirmed 2001 and steel wire rope as per IS:2266:2019.Reclaimed or recycled material should not be used .This will include drilling of 7.1mm dia holes in rails (4 Nos) and provision of two jumpers for each bond, clipping of bonds etc. with contractors own materials and tools as per instruction of Rly engineer at site.

50

169

7782.69

... More
Provision of bonding with GI wire 4mm dia ( 8 SWG) for track jumper & fish plate joints bonds. This will include drilling of 7.1mm dia holes in rails (4 Nos) and provision of two jumpers for each bond, clipping of bonds etc. with contractors own tools as per instruction of Rly engineer at site.

50

160

7362.02

... More
Removal of existing mechanical point fittings and FPL assembly f rom points, fixing of point machine, ground connection, adjustment and testing with crank handle for operation. Removal of ground connection , point machine after testing (duly numbered) and refixing of mechanical point fittings. This will include 19 fabrication and fixing of bent pipes with welded frame for cable entry to the point machine and termination of tail cable in point machine and wiring servicing of point machine & supply & filling of SAE 30 lubricating oil (500 ml approx). This also includes supply of all fixing material, necessary fitting & adjustment to make the mechanically operated points functional again. (Ordinary Layout/Derail switch/Double slip/Single slip). The work shall be done as per extant practice on C. Rly & the instruction of Rly engineer at site.

8

5689

41762.91

... More
"Fixing of point machine on newly laid turnout o n Wooden/MBC sleepers , fixing of ground connections, adjustment and testing with crank handle operations,Removal of ground connection & point 20 machines duly numbered. This will include fixing of bend pipes with welded frame for cable entry to machine. This will also includes necessary adjustment and smithy work, drilling of holes to tounge rails, fitting of insulation for tounge attachment, gauge plate & stretcher bars, cable termination & wiring if required. The work shall be done as per extant practice on C. Rly & the instruction of Rly engineer at site."

8

3526

25886.64

... More
Installation,fixing and wiring of Boxes for Key Lock Relays with contractors wiring & fixing material.The work shall be done as per extent practice on C.Rly & the instruction of site engineer.

1

-

2862.04

... More
Excavation of cable trench as per cable route plan,1.0 mt. deep and 300mm wide along side the track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm thickness after clearing of 22 route,bushes etc.It shall be ensured that top of the cables laid is at a depth of 0.8 m or more If it is less,then the width and depth shall be suitably increased and accordingly proportionate payment shall be made .In case depth of trench is not achievable due to site conditions,Proportionate payment will be made as per procedure.The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site.Drg No.SK 805

600

350

192675

... More
Excavation of cable trench as per cable route plan,1.0 mt. deep and 300mm wide along side the track in hard soil, conforming to distances as per cable route plan and refilling after cable laying. This work 23 includes covering of cable laid in trench by loose soil for a layer of 50mm thickness after clearing of route,bushes etc.It shall be ensured that top of the cables laid is at a depth of 0.8 m or more If it is less,then the width and depth shall be suitably increased and accordingly proportionate payment shall be made .In case depth of trench is not achievable due to site conditions,Proportionate payment will be made as per procedure.The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site.Drg No.SK 805 83B 15.00 cum 2916.67 43750.05 (-) 8.25 40140.67 24

100

583

53520.53

... More
Digging of trench 1.0M deep from rail flange/road level (for LC) and 0.3 mtrs to 0.6 Mtrs wide and 25 back filling after placing of DWC/RCC/GI pipe (Placing of DWC/RCC/GI pipe coverd separately) The ballast disturbed be screened and dressed as required by Engineerin-charge or his representatives and road tarred immediately.Drg No.SK 806

70

583

37464.37

... More
Laying of DWC/RCC pipes alongwith collars/RCCHalf round pipe in trenches at places of track and road crossings, platform cuttings etc. 87B 18.00 Kilometre 5197.42 93553.56 (-) 8.25 85835.39

240

56

12518.37

... More
Laying of signalling/Power/Telecom cable of various cores/sizes in trenches.

18

5197

85835.39

... More
Placing and securing of cable route markers in trenches at the specified interval and at diversions, joints etc along the cable route. The work shall be done as per extant practice on C Railways & the instruction of Rly engineer at site. 90B 8.00 Numbers 3562.19 28497.52 (-) 8.25 26146.47

50

12

574.81

... More
Jointing of 4 / 6 quad cable with Heat Shrinkable straight through Jointing Kit for 4 / 6 quad cable.

8

3562

26146.47

... More
Provision of brick masonary duct as per Rly.Drg.No. PA/N/CN/STD/19(modified) after cutting of platform/excavating the earth for the duct with contractor's own materials and restoring the excavated earth to its original condition.

10

2034

18669.75

... More
Whereever depth of 0.5 m cable trench is not feasible cable shall be protected as under :- Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench.

100

5329

488986.21

... More
"Fixing of modular terminal/fuse blocks alongwith all accessories with provision of fixing holes on 32 hylam sheets/side angles of Loc Box and fixing by galvanised nuts & bolts. This includes fixing of DIN channel alongwith PVC Comb type 'C' channel (size 2 inch x 2 inch) for cable termination on modular terminal. The PVC channel with cover to be supplied by firm as required. The work shall be done as per the instruction"

800

19

13982.7

... More
Termination of cable cores on ARA terminal/Disconnecting link/fuse blocks, in the apparatus Cases/ cable termination rack. This includes all associated works of pulling out the cable from underground. The work shall be done as per location plans and instructions of Rly engineer at site.

2000

7

13028.5

... More
Laying of GI pipes in on bridges/culverts/concrete drain/ mountain ridges etc. with suitable GI bend 34 shall be provided where there is turning of pipe as per instructions of the site engineer. GI Clamps at every 2 m as shown in the drawing to be fixed. Suitable holes to be made in the pipe before laying as per instructions of the site engineer. 100 mm dia. Drg No SK 808

120

143

15803.75

... More
Laying of RCC half round cement pipe of approximate size (150/300 mm dia X 2 Meter length) inside the trench after laying of cable. Pipes shall be placed as per directives of engineer

2000

36

66885.75

... More
Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of paints.Wherever required 36 contractor shall apply coating of epoxy paint also as per instructions of site-in-charge.Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. A) "Apparatus Case Full Size."

8

435

3196.13

... More
Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of paints.Wherever required 37 contractor shall apply coating of epoxy paint also as per instructions of site-in-charge.Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. B) "Apparatus case Half Size."

4

326

1200.05

... More
Painting of two coats of synthetic enamel paint over one coat of primer on the following after required38scraping & cleaning surface wherever necessary with contractor' own supply of paints.Wherever contractor shall apply coating of epoxy paint also as per instructions of site-in-charge.Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. C) "Track lead Junction Box. (Black enamel outside only)"

15

89

1228.17

... More
Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of paints.Wherever required 39 contractor shall apply coating of epoxy paint also as per instructions of site-in-charge.Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. D)"Point Machine with ground connections complete (Point Machine with Black enamel only outside and ground connections with Red Oxide)"

8

156

1147.02

... More
Lettering / Numbering of Signals, Point Machine, Track Lead Junction Boxes, Block Joints, Apparatus Cases etc. (each item to be taken as One Unit) This work will be carried out as per the standard practice being followed in Central Railway.

35

56

1818.85

... More
Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes. A) FULL CASE

8

263

1934.31

... More
Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes. B) HALF CASE

4

150

550.61

... More
Fabrication and fixing of phenolic laminated/Fibre glass sheet in location box by providing all 1 fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe covered string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783-1/2. with latest alterations & as per instructions of Rly engineer at site. A) FULL CASE

16

2251

36027.68

... More
Fabrication and fixing of phenolic laminated/Fibre glass sheet in location box by providing all 2 fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe covered string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783-1/2. with latest alterations & as per instructions of Rly engineer at site. B) HALF CASE Per

6

1984

11908.68

... More
Erection of Apparatus Cases. This includes filling of location foundations and plastering A) FULL CASE

16

1098

17568.64

... More
Erection of Apparatus Cases. This includes filling of location foundations and plastering B) HALF CASE

6

842

5054.4

... More
Excavation and Casting of Apparatus Case foundation with contractors Anchor bolts, cement, 7 ballast and other materials.The required Scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost A) Single Case as per Drg No SK 803

16

9887

158192.32

... More
Excavation and Casting of Apparatus Case foundation with contractors Anchor bolts, cement, ballast and other materials.The required Scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost B) Half Case as per Drg No SK 804

6

9693

58163.58

... More
Installation of earth electrode assenbly as per Drg.No.RE/S&T/SIG/Tender/SK726/85 including earth wire connected through GI wire 8 SWG supported on M.S. flat of size 6mm x 40 mm to earth electrode as 9 per drg. No.CR/S&T/SK-815 for sigg. Equipment such as lever frames, apparatus case, signals, relay racks,block insruments, and etc. as per RE manual. The earth value should be less than 10 Ohms including the lead wire. The value should be measured in presence of Rly. supervisor. It should be documented and painted on earth enclosure made of concrete.( only earth electrode will be supplied by Railway). All other material required for provision of earthing will be brought by the contractor.

22

2528

55619.08

... More
Excavation of cable trench as per cable route plan,1.0 mt. deep and 300mm wide along side the track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm thickness after clearing of 10 route,bushes etc.It shall be ensured that top of the cables laid is at a depth of 0.8 m or more If it is less,then the width and depth shall be suitably increased and accordingly proportionate payment shall be made .In case depth of trench is not achievable due to site conditions,Proportionate payment will be made as per procedure.The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site.Drg No.SK 805

621

350

217350

... More
Fixing of GI pipes for crossing the culverts, bridges etc. and concreting of ends with brick masonry at both ends as per the instruction of Rly engineer at site.

384

69

26868.48

... More
Laying of DWC/RCC pipes alongwith collars/RCCHalf round pipe in trenches at places of track and road crossings, platform cuttings etc.

320

56

18192

... More
Laying of signalling/Power/Telecom cable of various cores/sizes in trenches.

16

5197

83158.72

... More
Jointing of 4 / 6 quad cable with Heat Shrinkable straight through Jointing Kit for 4 / 6 quad cable.

48

3562

170985.12

... More
Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of paints.Wherever required 15 contractor shall apply coating of epoxy paint also as per instructions of site-in-charge.Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. A) "Apparatus case Full Size."

16

435

6967.04

... More
Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of paints.Wherever required 16 contractor shall apply coating of epoxy paint also as per instructions of site-in-charge.Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. B) "Apparatus case Half Size."

6

326

1961.94

... More
Lettering / Numbering of Signals, Point Machine, Track Lead Junction Boxes, Block Joints, Apparatus Cases etc. (each item to be taken as One Unit) This work will be carried out as per the standard practice being followed in Central Railway.

22

56

1246.08

... More
Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes. A) FULL SIZE

16

263

4216.48

... More
Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes. B) HALF CASE

6

150

900.18

... More
Fabrication and fixing of phenolic laminated/Fibre glass sheet in location box by providing all 1 fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe covered string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783-1/2. with latest alterations & as per instructions of Rly engineer at site.a) Single Case

6

2251

13510.38

... More
Fixing of ARA Terminalsand fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts.This includes provision of two additional holes on the board on either side for cable conductor entry.

3000

14

42150

... More
Termination of cable cores on ARA terminal/ fuse blocks,in the apparatus Cases/ cable termination rack.This includes all associated works of pulling out the cable from underground. The work shall be done as per location plans and instructions of Rly engineer at site.

3000

10

31740

... More
Excavation and Casting of Apparatus Case foundation with contractors Anchor bolts, cement, ballast and other materials.The required Scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor ar his own cost (i) Single Case as per Drg No SK 803

6

9887

59322.12

... More
Erection of Apparatus Cases. This includes filling of location foundations and plastering (i) Single Case

6

1098

6588.24

... More
Installation of Eqpt. (Relays, resistance, chargers batteries etc.as applicable) & wiring of the same in apparatus Cases as per location diagrams & circuit diagrams, as per Instruction of site incharge and practice. (i) Single Case

6

1497

8986.32

... More
Installation of earth electrode assenbly as per Drg.No.RE/S&T/S IG/Tender/SK726/85 including earth wire connected through GI wire 8 SWG supported on M.S. flat of size 6mm x 40 mm to earth electrode as 7 per drg. No.CR/S&T/SK-815 for sigg. Equipment such as lever frames, apparatus case, signals, relay racks,block insruments, and etc. as per RE manual. The earth value should be less than 10 Ohms including the lead wire. The value should be measured in presence of Rly. supervisor. It should be documented and painted on earth enclosure made of concrete.( only earth electrode will be supplied by Railway). All other material required for provision of earthing will be brought by the contractor.

6

2528

15168.84

... More
Excavation of cable trench as per cable route plan,1.0 mt. deep and 300mm wide along side the track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm thickness after clearing of 8 route,bushes etc.It shall be ensured that top of the cables laid is at a depth of 0.8 m or more If it is less,then the width and depth shall be suitably increased and accordingly proportuonate payment shall be made .In case depth of trench is not achievable due to site conditions,Proportionate payment will be made as per procedure.The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site.Drg No.SK 805

100

350

35000

... More
Laying of DWC/RCC pipes alongwith collars/RCCHalf round pipe in trenches at places of track and road crossings, platform cuttings etc.

210

56

11938.5

... More
Laying of signalling/Power/Telecom cable of various cores/sizes in trenches.

6

5197

31184.52

... More
Placing and securing of cable route markers in trenches at the specified interval and at diversions, joints etc along the cable route. The work shall be done as per extant practice on C Railways & the instruction of Rly engineer at site.

10

12

125.3

... More
Whereever depth of 0.5 m cable trench is not feasible cable shall be protected as under :- Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench.

3

5329

15988.65

... More
Laying of GI pipes in on bridges/culverts/concrete drain/ mountain ridges etc. with suitable GI bend shall be provided where there is turning of pipe as per instructions of the site engineer. GI Clamps at every 2 m as shown in the drawing to be fixed. Suitable holes to be made in the pipe before laying as per instructions of the site engineer. 100 mm dia. Drg No SK 808

18

143

2583.72

... More
Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of paints. Wherever required 14 contractor shall apply coating of epoxy paint also as per instructions of site-in-charge.Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer.(i) Apparatus Case Full Size.

6

435

2612.64

... More
Fabrication and fixing of phenolic laminated/Fibre glass sheet in location box by providing all 1 fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe covered string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783-1/2. with latest alterations & as per instructions of Rly engineer at site. A) Single Case

4

2251

10628.17

... More
Fixing of ARA Terminalsand fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts.This includes provision of two additional holes on the board on either side for cable conductor entry.

500

14

8289.5

... More
Termination of cable cores on ARA terminal/ fuse blocks,in the apparatus Cases/ cable termination rack.This includes all associated works of pulling out the cable from underground. The work shall be done as per location plans and instructions of Rly engineer at site.

500

10

6242.2

... More
Excavation and Casting of Apparatus Case foundation with contractors Anchor bolts, cement, ballast and other materials.The required Scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost A)Single Case as per Drg No SK 803

4

9887

46666.73

... More
Erection of Apparatus Cases. This includes filling of location foundations and plastering A) Single Case

4

1098

5182.75

... More
Installation of Eqpt. (Relays, resistance, chargers batteries etc.as applicable) & wiring of the same in apparatus Cases as per location diagrams & circuit diagrams, as per Instruction of site incharge and practice. A) Single Case

4

1497

7069.24

... More
Provision of bonding with contractor's PVC jacketed wire rope for Track Lead connections.PVC jacketed wire rope should be of Galvanised steel wire rope 6mm dia (6 x 19 stranded wire with steel core of 6 7 mm dia ) sheathed with PVC 2mm wall thickness, overall thickness being 10mm PVC sheath should be made of type 6 compound as per IS 5831 of 1984 Reaffirmed 2001 and steel wire rope as per IS:2266:2019.Reclaimed or recycled material should not be used .This will include drilling of 7.1mm dia holes in rails (4 Nos) and provision of two jumpers for each bond, clipping of bonds etc. with contractors own materials and tools as per instruction of Rly engineer at site.

20

169

4003.74

... More
Provision of bonding with GI wire 4mm dia ( 8 SWG) for track jumper & fish plate joints bonds. This will include drilling of 7.1mm dia holes in rails (4 Nos) and provision of two jumpers for each bond, clipping of bonds etc. with contractors own tools as per instruction of Rly engineer at site.

50

160

9468.32

... More
Excavation of cable trench as per cable route plan,1.0 mt. deep and 300mm wide along side the track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm thickness after clearing of 9 route,bushes etc.It shall be ensured that top of the cables laid is at a depth of 0.8 m or more If it is less,then the width and depth shall be suitably increased and accordingly proportionate payment shall be made .In case depth of trench is not achievable due to site conditions,Proportionate payment will be made as per procedure.The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site.Drg No.SK 805

70

350

28910

... More
Cutting of all types of Roads/ platforms (except concrete type ) for trenching and excavation to depth of 300mmx300mm wide approx. and refilling after laying of RCC/GI/DWC pipe & to restore them to original condition. The work shall be done as per extant practice on C.Rly & instructions of Rly engineer at site.SK-807

2

2916

6883.34

... More
Fixing of GI pipes for crossing the culverts, bridges etc. and concreting of ends with brick masonry at both ends as per the instruction of Rly engineer at site.

12

69

990.78

... More
Digging of trench 1.0M deep from rail flange/road level (for LC) and 0.3 mtrs to 0.6 Mtrs wide and 12 back filling after placing of DWC/RCC/GI pipe (Placing of DWC/RCC/GI pipe coverd separately) The ballast disturbed be screened and dressed as required by Engineerin-charge or his representatives and road tarred immediately.Drg No.SK 806

20

583

13766.59

... More
Laying of DWC/RCC pipes alongwith collars/RCCHalf round pipe in trenches at places of track and road crossings, platform cuttings etc. 87B 7.00 Kilometre 5197.42 36381.94 18.00 42930.69

36

56

2414.99

... More
Jointing of 4 / 6 quad cable with Heat Shrinkable straight through Jointing Kit for 4 / 6 quad cable.

2

3562

8406.77

... More
Whereever depth of 0.5 m cable trench is not feasible cable shall be protected as under :- Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench.

1

5329

6288.87

... More
Laying of RCC half round cement pipe of approximate size (150/300 mm dia X 2 Meter length) inside the trench after laying of cable. Pipes shall be placed as per directives of engineer

200

36

8602.2

... More
"Fixing of modular terminal/fuse blocks alongwith all accessories with provision of fixing holes on 18 hylam sheets/side angles of Loc Box and fixing by galvanised nuts & bolts. This includes fixing of DIN channel alongwith PVC Comb type 'C' channel (size 2 inch x 2 inch) for cable termination on modular terminal. The PVC channel with cover to be supplied by firm as required. The work shall be done as per the instruction"

150

19

3371.85

... More
Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of paints.Wherever required 19 contractor shall apply coating of epoxy paint also as per instructions of site-in-charge.Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer. A) "Apparatus Case Full Size."

4

435

2055.28

... More
Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes. A) Full Case.

4

263

1243.86

... More
Installation of earth electrode assenbly as per Drg.No.RE/S&T/SIG/Tender/SK726/85 including earth wire connected through GI wire 8 SWG supported on M.S. flat of size 6mm x 40 mm to earth electrode as 21 per drg. No.CR/S&T/SK-815 for sigg. Equipment such as lever frames, apparatus case, signals, relay racks,block insruments, and etc. as per RE manual. The earth value should be less than 10 Ohms including the lead wire. The value should be measured in presence of Rly. supervisor. It should be documented and painted on earth enclosure made of concrete.( only earth electrode will be supplied by Railway). All other material required for provision of earthing will be brought by the contractor.

4

2528

11932.82

... More
Supply, checking of installation, testing and commissioning of SMPS based Integrated Power Supply confirming to RDSO specification RDSO/SPN/165/2012 version 3.0 for LC gates as per Central Rly Drg. No.SK-791/C along with Sealed Maintenance free VRLA battery set of 60 Cells (stackable), in combination of 55+5 Cells for SMPS based integrated power supply system, each cell of 2 Volt /200 AH Capacity,fully charged, conforming to RDSO Specification No.IRS: S:93/96(A) complete with connecting links and suitably numbered in stackable racks along with 1 set of user manuals. Scope of supply, installation and commissioning of IPS shall be as per RDSO letter no.STS/E/IPS/GENL. Dated 03/04/2008 (Inspection by RDSO)

1

1086755

1086755.22

... More
Supply of cable route marker as per RST/C/203 of FRP. (Inspection by Consignee)

50

360

18044

... More
Supply of True RMS Multimeter Fluke Make model 289 (Inspection by Consignee)

4

60425

241703.64

... More
TRMS Datalogging DMM Fine Tipmultimeter make-Rishabh 6016 or similar (Inspection by Consignee)

2

21956

43912.28

... More
"Design of alteration in existing Signalling Circuits & supply of modified signalling circuits including Panel diagram , Route section Plan , Selection Table , Fuse & Negative Tag. Analysis , Contact analysis , Relay Rack Arrangement and wire count sheets etc. in A3 size. Completion circuit shall be plotted in AutoCAD. The 4 contractor shall initially supply 2 sets of circuits duly signed by the circuit designer having substantial experience on design side for making such circuits, complete for approval of Railways. Railways will return one set of circuit to the contractor duly approved with alterations /corrections, if any. The contractor/Railway will commission the station with the based on these approved circuit diagram. The contractor will submit final tracing & CD ( soft copy of Drg.) based on panel testing,break test,square sheet test etc. to Railway for their final approval. complete in all respects along with 4 sets of final ."

2

95000

190000

... More
"Supply of second classcountry bricks of standard size 225mm x100mm x 75mm (Approx). NOTE :- If the specified size of bricks are not availablein the neighborhood then payment will be made on pro rate analysis" (Inspection by Consignee)

19002

2

44654.7

... More
Placing of bricks across the trench as per instructions of site-in-charge over the bed of loose soil on already laid cables.

19002

-

4180.44

... More
Supply of True RMS Multimeter Fluke Make model 289 (Inspection by Consignee)

1

84895

84895.2

... More
"Supply of second classcountry bricks of standard size 225mm x100mm x 75mm (Approx). NOTE :- If the specified size of bricks are not available in the neighborhood then payment will be made on pro rate analysis" (Inspection by Consignee)

3150

2

7402.5

... More
Placing of bricks across the trench as per instructions of site-in-charge over the bed of loose soil on already laid cables.

3150

-

693

... More
TRMS Datalogging DMM Fine Tip multimeter make-Rishabh 6016 or similar (Inspection by Consignee)

2

21653

43306

... More
Supply of Multi strand single core flexible cable of 16/0.2 mm as per IRS 76/89 with latest amendment if any (Inspection by Consignee)

1

5852

5852.8



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.